{{#Wiki_filter:Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909
{{#Wiki_filter:Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5018107 Page 1 of 2 July 11, 2023 Yen-Ju Chen Division of Fuel Management Office of Nuclear Material Safety and Safeguards ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No. 72-1032, Certificate of Compliance (CoC) No. 1032 CAC No. 001028, EPID No. L-2021-LLA-0053  
 
July 11, 2023
 
Yen-Ju Chen Division of Fuel Management Office of Nuclear Material Safety and Safeguards
 
ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
 
Docket No. 72-1032, Certificate of Compliance (CoC) No. 1032 CAC No. 001028, EPID No. L-2021-LLA-0053


==Subject:==
==Subject:==
HI-STORM FW Amendment 7 RAI Responses Part 5 Clarification Corrected Attachments 4 and 5
HI-STORM FW Amendment 7 RAI Responses Part 5 Clarification Corrected Attachments 4 and 5  


==Dear Ms. Chen:==
==Dear Ms. Chen:==
Holtec International submitted HI-STORM FW Amendment 7 RAI Response Clarifications (ADAMS Accension No. ML23181A192). This letter contains corrected Attachments 4 and 5 to that submittal (ADAMS Accension No. ML23181A197 and ML23181A198).
Holtec International submitted HI-STORM FW Amendment 7 RAI Response Clarifications (ADAMS Accension No. ML23181A192). This letter contains corrected Attachments 4 and 5 to that submittal (ADAMS Accension No. ML23181A197 and ML23181A198).
Since Attachment 4 contains Holtec proprietary information, an affidavit requesting this information be withheld in accordance with 10CFR2.390 is included as Attachment 1 to this letter.
Since Attachment 4 contains Holtec proprietary information, an affidavit requesting this information be withheld in accordance with 10CFR2.390 is included as Attachment 1 to this letter.
Please contact me at (856) 797-0900 Extension 3326 if you have any questions or require any additional information.
Please contact me at (856) 797-0900 Extension 3326 if you have any questions or require any additional information.
Sincerely, Denise Elisio Licensing Engineer, Holtec International


Sincerely,
Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5018107 Page 2 of 2 Attachments: : Affidavit in Accordance with 10CFR2.390 Corrected Attachments to Holtec Letter 5018106: : HI-STORM FW FSAR Proposed Revision 10I, changed pages (proprietary) : HI-STORM FW FSAR Proposed Revision 10I, changed pages (non-proprietary)}}
 
Denise Elisio
 
Licensing Engineer, Holtec International
 
Document ID 5018107 Page 1 of 2 Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909
 
Attachments: : Affidavit in Accordance with 10CFR2.390
 
Corrected Attachments to Holtec Letter 5018106: : HI-STORM FW FSAR Proposed Revision 10I, changed pages (proprietary) : HI-STORM FW FSAR Proposed Revision 10I, changed pages (non-proprietary)
 
Document ID 5018107 Page 2 of 2}}

Latest revision as of 02:46, 27 November 2024

International, HI-STORM FW Amendment 7 RAI Responses Part 5 Clarification Corrected Attachments 4 and 5
ML23192A032
Person / Time
Site: 07201032
Issue date: 07/11/2023
From: Elisio D
Holtec
To: Yen-Ju Chen
Office of Nuclear Material Safety and Safeguards, Document Control Desk
Shared Package
ML23192A031 List:
References
CAC 001028, EPID L-2021-LLA-0053, 5018107
Download: ML23192A032 (1)


Text

Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5018107 Page 1 of 2 July 11, 2023 Yen-Ju Chen Division of Fuel Management Office of Nuclear Material Safety and Safeguards ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No. 72-1032, Certificate of Compliance (CoC) No. 1032 CAC No. 001028, EPID No. L-2021-LLA-0053

Subject:

HI-STORM FW Amendment 7 RAI Responses Part 5 Clarification Corrected Attachments 4 and 5

Dear Ms. Chen:

Holtec International submitted HI-STORM FW Amendment 7 RAI Response Clarifications (ADAMS Accension No. ML23181A192). This letter contains corrected Attachments 4 and 5 to that submittal (ADAMS Accension No. ML23181A197 and ML23181A198).

Since Attachment 4 contains Holtec proprietary information, an affidavit requesting this information be withheld in accordance with 10CFR2.390 is included as Attachment 1 to this letter.

Please contact me at (856) 797-0900 Extension 3326 if you have any questions or require any additional information.

Sincerely, Denise Elisio Licensing Engineer, Holtec International

Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5018107 Page 2 of 2 Attachments: : Affidavit in Accordance with 10CFR2.390 Corrected Attachments to Holtec Letter 5018106: : HI-STORM FW FSAR Proposed Revision 10I, changed pages (proprietary) : HI-STORM FW FSAR Proposed Revision 10I, changed pages (non-proprietary)