{{#Wiki_filter:PROPOSED CERTIFICATE OF COMPLIANCE NO. 1014 APPENDIX B APPROVED CONTENTS AND DESIGN FEATURES FOR THE HI-STORM 100 CASK SYSTEM
{{#Wiki_filter:PROPOSED CERTIFICATE OF COMPLIANCE NO. 1014 APPENDIX B APPROVED CONTENTS AND DESIGN FEATURES FOR THE HI-STORM 100 CASK SYSTEM  


TABLE OF CONTENTS 1.0 DEFINITIONS ...................................................................................................................1-1 2.0 APPROVED CONTENTS .................................................................................................2-1 2.1     Fuel Specification and Loading Conditions ...................................................................2-1 2.2     Violations ......................................................................................................................2-2 2.3     Not Used.......................................................................................................................2-2 2.4     Decay Heat, Burnup & Cooling Time Limits for ZR Clad Fuel .....................................2-48 Figure 2.1-1         Fuel Loading Regions - MPC-24 ..................................................................2-3 Figure 2.1-2         Fuel Loading Regions - MPC-24E/24EF ......................................................2-4 Figure 2.1-3         Fuel Loading Regions - MPC-32/32F ...........................................................2-5 Figure 2.1-4         Fuel Loading Regions - MPC-68/68FF/68M .................................................2-6 Figure 2.4-1         Per Cell Allowable Heat Loads (kW) - MPC-68M ........................................2-71 Table 2.1-1           Fuel Assembly Limits ....................................................................................2-7 Table 2.1-2           PWR Fuel Assembly Characteristics ..........................................................2-37 Table 2.1-3           BWR Fuel Assembly Characteristics ..........................................................2-42 Table 2.1-4           Table Deleted ....................................................................................................
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B i
Table 2.1-5           Table Deleted ....................................................................................................
TABLE OF CONTENTS 1.0 DEFINITIONS...................................................................................................................1-1 2.0 APPROVED CONTENTS.................................................................................................2-1 2.1 Fuel Specification and Loading Conditions...................................................................2-1 2.2 Violations......................................................................................................................2-2 2.3 Not Used.......................................................................................................................2-2 2.4 Decay Heat, Burnup & Cooling Time Limits for ZR Clad Fuel..................................... 2-48 Figure 2.1-1 Fuel Loading Regions - MPC-24..................................................................2-3 Figure 2.1-2 Fuel Loading Regions - MPC-24E/24EF......................................................2-4 Figure 2.1-3 Fuel Loading Regions - MPC-32/32F...........................................................2-5 Figure 2.1-4 Fuel Loading Regions - MPC-68/68FF/68M.................................................2-6 Figure 2.4-1 Per Cell Allowable Heat Loads (kW) - MPC-68M........................................ 2-71 Table 2.1-1 Fuel Assembly Limits....................................................................................2-7 Table 2.1-2 PWR Fuel Assembly Characteristics.......................................................... 2-37 Table 2.1-3 BWR Fuel Assembly Characteristics.......................................................... 2-42 Table 2.1-4 Table Deleted....................................................................................................
Table 2.1-6           Table Deleted ....................................................................................................
Table 2.1-5 Table Deleted....................................................................................................
Table 2.1-7           Table Deleted ....................................................................................................
Table 2.1-6 Table Deleted....................................................................................................
Table 2.1-8           Non-Fuel Hardware Cooling and Average Burnup ......................................2-47 Table 2.4-1           Maximum Allowable Decay Heat per Fuel Storage Location .......................2-48 Table 2.4-2           Fuel Storage Locations per MPC ................................................................2-50 Table 2.4-3           PWR Fuel Assembly Cooling Time-Dependent Coefficients .......................2-53 Table 2.4-4           BWR Fuel Assembly Cooling Time-Dependent Coefficients .......................2-61 Table 2.4-5           Heat Load for Damaged Fuel Assemblies and Fuel Debris under Regionalized Loading ..................................................................................2-50 3.0 DESIGN FEATURES ........................................................................................................3-1 3.1     Site ...............................................................................................................................3-1 3.2     Design Features Important for Criticality Control ..........................................................3-1 3.3     Codes and Standards ...................................................................................................3-2 3.4     Site Specific Parameters and Analyses ......................................................................3-13 3.5     Cask Transfer Facility (CTF).......................................................................................3-17 3.6     Forced Helium Dehydration System ...........................................................................3-20 3.7     Supplemental Cooling System ....................................................................................3-22 3.8     Combustible Gas Monitoring During MPC Lid Welding and Cutting ............................3-25 3.9     Environmental Temperature Requirements ................................................................3-25 Table 3-1         List of ASME Code Alternatives for HI-STORM 100 Cask System ....................3-4 Table 3-2         Load Combinations and Service Condition Definitions for the CTF Structure .................................................................................................3-19 Table 3-3         Requirements for Supplemental Cooling System ............................................3-24 Certificate of Compliance No. 1014                                                                              Amendment No. 12 Appendix B                                                            i
Table 2.1-7 Table Deleted....................................................................................................
Table 2.1-8 Non-Fuel Hardware Cooling and Average Burnup...................................... 2-47 Table 2.4-1 Maximum Allowable Decay Heat per Fuel Storage Location....................... 2-48 Table 2.4-2 Fuel Storage Locations per MPC................................................................ 2-50 Table 2.4-3 PWR Fuel Assembly Cooling Time-Dependent Coefficients....................... 2-53 Table 2.4-4 BWR Fuel Assembly Cooling Time-Dependent Coefficients....................... 2-61 Table 2.4-5 Heat Load for Damaged Fuel Assemblies and Fuel Debris under Regionalized Loading..................................................................................2-50 3.0 DESIGN FEATURES........................................................................................................3-1 3.1 Site...............................................................................................................................3-1 3.2 Design Features Important for Criticality Control..........................................................3-1 3.3 Codes and Standards...................................................................................................3-2 3.4 Site Specific Parameters and Analyses...................................................................... 3-13 3.5 Cask Transfer Facility (CTF)....................................................................................... 3-17 3.6 Forced Helium Dehydration System........................................................................... 3-20 3.7 Supplemental Cooling System.................................................................................... 3-22 3.8 Combustible Gas Monitoring During MPC Lid Welding and Cutting............................ 3-25 3.9 Environmental Temperature Requirements................................................................ 3-25 Table 3-1 List of ASME Code Alternatives for HI-STORM 100 Cask System....................3-4 Table 3-2 Load Combinations and Service Condition Definitions for the CTF Structure................................................................................................. 3-19 Table 3-3 Requirements for Supplemental Cooling System............................................ 3-24  


Definitions 1.0 1.0 Definitions Refer to Appendix A for Definitions.
Definitions 1.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 1-1 1.0 Definitions Refer to Appendix A for Definitions.
Certificate of Compliance No. 1014       Amendment No. 12 Appendix B                           1-1


Approved Contents 2.0 2.0     APPROVED CONTENTS 2.1 Fuel Specifications and Loading Conditions 2.1.1 Fuel To Be Stored In The HI-STORM 100 SFSC System
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-1 2.0 APPROVED CONTENTS 2.1 Fuel Specifications and Loading Conditions 2.1.1 Fuel To Be Stored In The HI-STORM 100 SFSC System
: a. INTACT FUEL ASSEMBLIES, UNDAMAGED FUEL ASSEMBLIES, DAMAGED FUEL ASSEMBLIES, FUEL DEBRIS, and NON-FUEL HARDWARE meeting the limits specified in Table 2.1-1 and other referenced tables may be stored in the HI-STORM 100 SFSC System.
: a.
: b. For MPCs partially loaded with stainless steel clad fuel assemblies, all remaining fuel assemblies in the MPC shall meet the decay heat generation limit for the stainless steel clad fuel assemblies.
INTACT FUEL ASSEMBLIES, UNDAMAGED FUEL ASSEMBLIES, DAMAGED FUEL ASSEMBLIES, FUEL DEBRIS, and NON-FUEL HARDWARE meeting the limits specified in Table 2.1-1 and other referenced tables may be stored in the HI-STORM 100 SFSC System.
: c. For MPCs partially loaded with array/class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A fuel assemblies, all remaining ZR clad INTACT FUEL ASSEMBLIES in the MPC shall meet the decay heat generation limits for the 6x6A, 6x6B, 6x6C, 7x7A and 8x8A fuel assemblies.
: b.
: d. All BWR fuel assemblies may be stored with or without ZR channels with the exception of array/class 10x10D and 10x10E fuel assemblies, which may be stored with or without ZR or stainless steel channels.
For MPCs partially loaded with stainless steel clad fuel assemblies, all remaining fuel assemblies in the MPC shall meet the decay heat generation limit for the stainless steel clad fuel assemblies.
: c.
For MPCs partially loaded with array/class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A fuel assemblies, all remaining ZR clad INTACT FUEL ASSEMBLIES in the MPC shall meet the decay heat generation limits for the 6x6A, 6x6B, 6x6C, 7x7A and 8x8A fuel assemblies.
: d.
All BWR fuel assemblies may be stored with or without ZR channels with the exception of array/class 10x10D and 10x10E fuel assemblies, which may be stored with or without ZR or stainless steel channels.
2.1.2 Uniform Fuel Loading Any authorized fuel assembly may be stored in any fuel storage location, subject to other restrictions related to DAMAGED FUEL, FUEL DEBRIS, and NON-FUEL HARDWARE specified in the CoC.
2.1.2 Uniform Fuel Loading Any authorized fuel assembly may be stored in any fuel storage location, subject to other restrictions related to DAMAGED FUEL, FUEL DEBRIS, and NON-FUEL HARDWARE specified in the CoC.
(continued)
(continued)  
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-1


Approved Contents 2.0 2.0 Approved Contents 2.1 Fuel Specifications and Loading Conditions (contd) 2.1.3 Regionalized Fuel Loading Users may choose to store fuel using regionalized loading in lieu of uniform loading to allow higher heat emitting fuel assemblies to be stored than would otherwise be able to be stored using uniform loading. Figures 2.1-1 through 2.1-4 define the regions for the MPC-24, MPC-24E, MPC-24EF, MPC-32, MPC-32F, MPC-68, MPC-68FF, and MPC-68M models, respectively 1. Fuel assemblydecay heat limits for regionalized loading are specified in Section 2.4.2. Fuel assemblies used in regionalized loading shall meet all other applicable limits specified in Tables 2.1-1 through 2.1-3.
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-2 2.0 Approved Contents 2.1 Fuel Specifications and Loading Conditions (contd) 2.1.3 Regionalized Fuel Loading Users may choose to store fuel using regionalized loading in lieu of uniform loading to allow higher heat emitting fuel assemblies to be stored than would otherwise be able to be stored using uniform loading. Figures 2.1-1 through 2.1-4 define the regions for the MPC-24, MPC-24E, MPC-24EF, MPC-32, MPC-32F, MPC-68, MPC-68FF, and MPC-68M models, respectively1. Fuel assemblydecay heat limits for regionalized loading are specified in Section 2.4.2. Fuel assemblies used in regionalized loading shall meet all other applicable limits specified in Tables 2.1-1 through 2.1-3.
2.2 Violations If any Fuel Specifications or Loading Conditions of 2.1 are violated, the following actions shall be completed:
2.2 Violations If any Fuel Specifications or Loading Conditions of 2.1 are violated, the following actions shall be completed:
2.2.1 The affected fuel assemblies shall be placed in a safe condition.
2.2.1 The affected fuel assemblies shall be placed in a safe condition.
Line 46: Line 49:
2.3 Not Used 1
2.3 Not Used 1
These figures are only intended to distinguish the fuel loading regions. Other details of the basket design are illustrative and may not reflect the actual basket design details.
These figures are only intended to distinguish the fuel loading regions. Other details of the basket design are illustrative and may not reflect the actual basket design details.
The design drawings should be consulted for basket design details.
The design drawings should be consulted for basket design details.  
Certificate of Compliance No. 1014                                                  Amendment No. 12 Appendix B                                          2-2


Approved Contents 2.0 Figure 2.1-1 Fuel Loading Regions - MPC-24 Certificate of Compliance No. 1014                     Amendment No. 12 Appendix B                             2-3
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-3 Figure 2.1-1 Fuel Loading Regions - MPC-24


Approved Contents 2.0 Figure 2.1-2 Fuel Loading Regions - MPC-24E/24EF Certificate of Compliance No. 1014                        Amendment No. 12 Appendix B                            2-4
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-4 Figure 2.1-2 Fuel Loading Regions - MPC-24E/24EF  


Approved Contents 2.0 Figure 2.1-3 Fuel Loading Regions - MPC-32/32F Certificate of Compliance No. 1014                        Amendment No. 12 Appendix B                            2-5
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-5 Figure 2.1-3 Fuel Loading Regions - MPC-32/32F  


Approved Contents 2.0 Figure 2.1-4 Fuel Loading Regions - MPC-68/68FF/68M Certificate of Compliance No. 1014                      Amendment No. 12 Appendix B                            2-6
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-6 Figure 2.1-4 Fuel Loading Regions - MPC-68/68FF/68M  


Approved Contents 2.0 Table 2.1-1 (page 1 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-7 Table 2.1-1 (page 1 of 30)
Fuel Assembly Limits I. MPC MODEL: MPC-24 A. Allowable Contents
Fuel Assembly Limits I. MPC MODEL: MPC-24 A. Allowable Contents
: 1. Uranium oxide, PWR INTACT FUEL ASSEMBLIES listed in Table 2.1-2, with or without NON-FUEL HARDWARE and meeting the following specifications (Note 1):
: 1. Uranium oxide, PWR INTACT FUEL ASSEMBLIES listed in Table 2.1-2, with or without NON-FUEL HARDWARE and meeting the following specifications (Note 1):
: a. Cladding Type:                       ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class.
: a. Cladding Type:
: b. Initial Enrichment:                 As specified in Table 2.1-2 for the applicable fuel assembly array/class.
ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class.
: b. Initial Enrichment:
As specified in Table 2.1-2 for the applicable fuel assembly array/class.
: c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: i. Array/Classes                 Cooling time 8 years and an average 14x14D,14x14E, and            burnup 40,000 MWD/MTU.
: i. Array/Classes 14x14D,14x14E, and 15x15G Cooling time 8 years and an average burnup 40,000 MWD/MTU.
15x15G ii. All Other Array/Classes     Cooling time and average burnup as specified in Section 2.4.
ii. All Other Array/Classes Cooling time and average burnup as specified in Section 2.4.
ii. NON-FUEL HARDWARE           As specified in Table 2.1-8.
ii. NON-FUEL HARDWARE As specified in Table 2.1-8.  
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-7


Approved Contents 2.0 Table 2.1-1 (page 2 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-8 Table 2.1-1 (page 2 of 30)
Fuel Assembly Limits I. MPC MODEL: MPC-24 (continued)
Fuel Assembly Limits I. MPC MODEL: MPC-24 (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: d. Decay Heat Per Fuel Storage Location:
: d. Decay Heat Per Fuel Storage Location:
: i. Array/Classes 14x14D,         710 Watts 14x14E, and 15x15G ii. All Other Array/Classes     As specified in Section 2.4.
: i. Array/Classes 14x14D, 14x14E, and 15x15G 710 Watts ii. All Other Array/Classes As specified in Section 2.4.
: e. Fuel Assembly Length:                   176.8 inches (nominal design)
: e. Fuel Assembly Length:
: f. Fuel Assembly Width:                     8.54 inches (nominal design)
176.8 inches (nominal design)
: g. Fuel Assembly Weight:                   1720 lbs (including NON-FUEL HARDWARE) for assemblies that do not require fuel spacers, otherwise 1680 lbs (including NON-FUEL HARDWARE)
: f. Fuel Assembly Width:
8.54 inches (nominal design)
: g. Fuel Assembly Weight:
1720 lbs (including NON-FUEL HARDWARE) for assemblies that do not require fuel spacers, otherwise 1680 lbs (including NON-FUEL HARDWARE)
B. Quantity per MPC: Up to 24 fuel assemblies.
B. Quantity per MPC: Up to 24 fuel assemblies.
C. Deleted.
C. Deleted.
D. DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS are not authorized for loading into the MPC-24.
D. DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS are not authorized for loading into the MPC-24.
E. One NSA is authorized for loading into the MPC-24.
E. One NSA is authorized for loading into the MPC-24.
Note 1:       Fuel assemblies containing BPRAs, TPDs, WABAs, water displacement guide tube plugs, orifice rod assemblies, or vibration suppressor inserts with or without ITTRs, may be stored in any fuel storage location. Fuel assemblies containing APSRs or NSAs may only be loaded in fuel storage locations 9, 10, 15, and/or 16. Fuel assemblies containing CRAs, RCCAs, CEAs may only be stored in fuel storage locations 4, 5, 8 - 11, 14 - 17, 20 and/or 21 (see Figure 2.1-1). These requirements are in addition to any other requirements specified for uniform or regionalized fuel loading.
Note 1:
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-8
Fuel assemblies containing BPRAs, TPDs, WABAs, water displacement guide tube plugs, orifice rod assemblies, or vibration suppressor inserts with or without ITTRs, may be stored in any fuel storage location. Fuel assemblies containing APSRs or NSAs may only be loaded in fuel storage locations 9, 10, 15, and/or 16. Fuel assemblies containing CRAs, RCCAs, CEAs may only be stored in fuel storage locations 4, 5, 8 - 11, 14 - 17, 20 and/or 21 (see Figure 2.1-1). These requirements are in addition to any other requirements specified for uniform or regionalized fuel loading.  


Approved Contents 2.0 Table 2.1-1 (page 3 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-9 Table 2.1-1 (page 3 of 30)
Fuel Assembly Limits II. MPC MODEL: MPC-68F A. Allowable Contents
Fuel Assembly Limits II. MPC MODEL: MPC-68F A. Allowable Contents
: 1. Uranium oxide, BWR INTACT FUEL ASSEMBLIES, with or without ZR channels. Uranium oxide BWR INTACT FUEL ASSEMBLIES shall meet the criteria specified in Table 2.1-3 for fuel assembly array class 6x6A, 6x6C, 7x7A or 8x8A, and meet the following specifications:
: 1. Uranium oxide, BWR INTACT FUEL ASSEMBLIES, with or without ZR channels. Uranium oxide BWR INTACT FUEL ASSEMBLIES shall meet the criteria specified in Table 2.1-3 for fuel assembly array class 6x6A, 6x6C, 7x7A or 8x8A, and meet the following specifications:
: a. Cladding Type:                           ZR
: a. Cladding Type:
: b. Maximum PLANAR-AVERAGE                   As specified in Table 2.1-3 for the INITIAL ENRICHMENT:                      applicable fuel assembly array/class.
ZR
: c. Initial Maximum Rod Enrichment:         As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:
: d. Post-irradiation Cooling Time and       Cooling time 18 years and an average Average Burnup Per Assembly:            burnup 30,000 MWD/MTU.
As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: e. Decay Heat Per Assembly                   115 Watts
: c. Initial Maximum Rod Enrichment:
: f. Fuel Assembly Length:                     135.0 inches (nominal design)
As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: g. Fuel Assembly Width:                     4.70 inches (nominal design)
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: h. Fuel Assembly Weight:                     400 lbs, including channels Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      2-9
Cooling time 18 years and an average burnup 30,000 MWD/MTU.
: e. Decay Heat Per Assembly 115 Watts
: f. Fuel Assembly Length:
135.0 inches (nominal design)
: g. Fuel Assembly Width:
4.70 inches (nominal design)
: h. Fuel Assembly Weight:
400 lbs, including channels  


Approved Contents 2.0 Table 2.1-1 (page 4 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-10 Table 2.1-1 (page 4 of 30)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: 2. Uranium oxide, BWR DAMAGED FUEL ASSEMBLIES, with or without ZR channels, placed in DAMAGED FUEL CONTAINERS. Uranium oxide BWR DAMAGED FUEL ASSEMBLIES shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6A, 6x6C, 7x7A, or 8x8A, and meet the following specifications:
: 2. Uranium oxide, BWR DAMAGED FUEL ASSEMBLIES, with or without ZR channels, placed in DAMAGED FUEL CONTAINERS. Uranium oxide BWR DAMAGED FUEL ASSEMBLIES shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6A, 6x6C, 7x7A, or 8x8A, and meet the following specifications:
: a. Cladding Type:                         ZR
: a. Cladding Type:
: b. Maximum PLANAR-AVERAGE                 As specified in Table 2.1-3 for the INITIAL ENRICHMENT:                    applicable fuel assembly array/class.
ZR
: c. Initial Maximum Rod Enrichment:         As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:
: d. Post-irradiation Cooling Time and       Cooling time 18 years and an average Average Burnup Per Assembly:            burnup 30,000 MWD/MTU.
As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: e. Decay Heat Per Assembly:                 115 Watts
: c. Initial Maximum Rod Enrichment:
: f. Fuel Assembly Length:                   135.0 inches (nominal design)
As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: g. Fuel Assembly Width:                     4.70 inches (nominal design)
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: h. Fuel Assembly Weight:                   550 lbs, including channels and DFC Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-10
Cooling time 18 years and an average burnup 30,000 MWD/MTU.
: e. Decay Heat Per Assembly:
115 Watts
: f. Fuel Assembly Length:
135.0 inches (nominal design)
: g. Fuel Assembly Width:
4.70 inches (nominal design)
: h. Fuel Assembly Weight:
550 lbs, including channels and DFC  


Approved Contents 2.0 Table 2.1-1 (page 5 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-11 Table 2.1-1 (page 5 of 30)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: 3. Uranium oxide, BWR FUEL DEBRIS, with or without ZR channels, placed in DAMAGED FUEL CONTAINERS. The original fuel assemblies for the uranium oxide BWR FUEL DEBRIS shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6A, 6x6C, 7x7A, or 8x8A, and meet the following specifications:
: 3. Uranium oxide, BWR FUEL DEBRIS, with or without ZR channels, placed in DAMAGED FUEL CONTAINERS. The original fuel assemblies for the uranium oxide BWR FUEL DEBRIS shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6A, 6x6C, 7x7A, or 8x8A, and meet the following specifications:
: a. Cladding Type:                         ZR
: a. Cladding Type:
: b. Maximum PLANAR-AVERAGE                 As specified in Table 2.1-3 for the INITIAL ENRICHMENT:                    applicable original fuel assembly array/class.
ZR
: c. Initial Maximum Rod Enrichment:         As specified in Table 2.1-3 for the applicable original fuel assembly array/class.
: b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:
: d. Post-irradiation Cooling Time and       Cooling time 18 years and an average Average Burnup Per Assembly            burnup 30,000 MWD/MTU for the original fuel assembly.
As specified in Table 2.1-3 for the applicable original fuel assembly array/class.
: e. Decay Heat Per Assembly                 115 Watts
: c. Initial Maximum Rod Enrichment:
: f. Original Fuel Assembly Length           135.0 inches (nominal design)
As specified in Table 2.1-3 for the applicable original fuel assembly array/class.
: g. Original Fuel Assembly Width             4.70 inches (nominal design)
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly Cooling time 18 years and an average burnup 30,000 MWD/MTU for the original fuel assembly.
: h. Fuel Debris Weight                       550 lbs, including channels and DFC Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                    2-11
: e. Decay Heat Per Assembly 115 Watts
: f. Original Fuel Assembly Length 135.0 inches (nominal design)
: g. Original Fuel Assembly Width 4.70 inches (nominal design)
: h. Fuel Debris Weight 550 lbs, including channels and DFC  


Approved Contents 2.0 Table 2.1-1 (page 6 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-12 Table 2.1-1 (page 6 of 30)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: 4. Mixed oxide (MOX), BWR INTACT FUEL ASSEMBLIES, with or without ZR channels. MOX BWR INTACT FUEL ASSEMBLIES shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6B, and meet the following specifications:
: 4. Mixed oxide (MOX), BWR INTACT FUEL ASSEMBLIES, with or without ZR channels. MOX BWR INTACT FUEL ASSEMBLIES shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6B, and meet the following specifications:
: a. Cladding Type:                           ZR
: a. Cladding Type:
: b. Maximum PLANAR-AVERAGE                   As specified in Table 2.1-3 for fuel INITIAL ENRICHMENT:                      assembly array/class 6x6B.
ZR
: c. Initial Maximum Rod Enrichment:         As specified in Table 2.1-3 for fuel assembly array/class 6x6B.
: b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:
: d. Post-irradiation Cooling Time and       Cooling time 18 years and an average Average Burnup Per Assembly:            burnup 30,000 MWD/MTIHM.
As specified in Table 2.1-3 for fuel assembly array/class 6x6B.
: e. Decay Heat Per Assembly                   115 Watts
: c. Initial Maximum Rod Enrichment:
: f. Fuel Assembly Length:                     135.0 inches (nominal design)
As specified in Table 2.1-3 for fuel assembly array/class 6x6B.
: g. Fuel Assembly Width:                     4.70 inches (nominal design)
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: h. Fuel Assembly Weight:                     400 lbs, including channels Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                    2-12
Cooling time 18 years and an average burnup 30,000 MWD/MTIHM.
: e. Decay Heat Per Assembly 115 Watts
: f. Fuel Assembly Length:
135.0 inches (nominal design)
: g. Fuel Assembly Width:
4.70 inches (nominal design)
: h. Fuel Assembly Weight:
400 lbs, including channels  


Approved Contents 2.0 Table 2.1-1 (page 7 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-13 Table 2.1-1 (page 7 of 30)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: 5. Mixed oxide (MOX), BWR DAMAGED FUEL ASSEMBLIES, with or without ZR channels, placed in DAMAGED FUEL CONTAINERS. MOX BWR DAMAGED FUEL ASSEMBLIES shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6B, and meet the following specifications:
: 5. Mixed oxide (MOX), BWR DAMAGED FUEL ASSEMBLIES, with or without ZR channels, placed in DAMAGED FUEL CONTAINERS. MOX BWR DAMAGED FUEL ASSEMBLIES shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6B, and meet the following specifications:
: a. Cladding Type:                         ZR
: a. Cladding Type:
: b. Maximum PLANAR-AVERAGE                 As specified in Table 2.1-3 for fuel INITIAL ENRICHMENT:                    assembly array/class 6x6B.
ZR
: c. Initial Maximum Rod Enrichment:       As specified in Table 2.1-3 for fuel assembly array/class 6x6B.
: b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:
: d. Post-irradiation Cooling Time and     Cooling time 18 years and an average Average Burnup Per Assembly:          burnup 30,000 MWD/MTIHM.
As specified in Table 2.1-3 for fuel assembly array/class 6x6B.
: e. Decay Heat Per Assembly                 115 Watts
: c. Initial Maximum Rod Enrichment:
: f. Fuel Assembly Length:                   135.0 inches (nominal design)
As specified in Table 2.1-3 for fuel assembly array/class 6x6B.
: g. Fuel Assembly Width:                   4.70 inches (nominal design)
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: h. Fuel Assembly Weight:                   550 lbs, including channels and DFC Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                  2-13
Cooling time 18 years and an average burnup 30,000 MWD/MTIHM.
: e. Decay Heat Per Assembly 115 Watts
: f. Fuel Assembly Length:
135.0 inches (nominal design)
: g. Fuel Assembly Width:
4.70 inches (nominal design)
: h. Fuel Assembly Weight:
550 lbs, including channels and DFC  


Approved Contents 2.0 Table 2.1-1 (page 8 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-14 Table 2.1-1 (page 8 of 30)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: 6. Mixed Oxide (MOX), BWR FUEL DEBRIS, with or without ZR channels, placed in DAMAGED FUEL CONTAINERS. The original fuel assemblies for the MOX BWR FUEL DEBRIS shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6B, and meet the following specifications:
: 6. Mixed Oxide (MOX), BWR FUEL DEBRIS, with or without ZR channels, placed in DAMAGED FUEL CONTAINERS. The original fuel assemblies for the MOX BWR FUEL DEBRIS shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6B, and meet the following specifications:
: a. Cladding Type:                         ZR
: a. Cladding Type:
: b. Maximum PLANAR-AVERAGE                 As specified in Table 2.1-3 for original INITIAL ENRICHMENT:                    fuel assembly array/class 6x6B.
ZR
: c. Initial Maximum Rod Enrichment:       As specified in Table 2.1-3 for original fuel assembly array/class 6x6B.
: b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:
: d. Post-irradiation Cooling Time and     Cooling time 18 years and an average Average Burnup Per Assembly:          burnup 30,000 MWD/MTIHM for the original fuel assembly.
As specified in Table 2.1-3 for original fuel assembly array/class 6x6B.
: e. Decay Heat Per Assembly                 115 Watts
: c. Initial Maximum Rod Enrichment:
: f. Original Fuel Assembly Length:         135.0 inches (nominal design)
As specified in Table 2.1-3 for original fuel assembly array/class 6x6B.
: g. Original Fuel Assembly Width:           4.70 inches (nominal design)
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: h. Fuel Debris Weight:                     550 lbs, including channels and DFC Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                  2-14
Cooling time 18 years and an average burnup 30,000 MWD/MTIHM for the original fuel assembly.
: e. Decay Heat Per Assembly 115 Watts
: f. Original Fuel Assembly Length:
135.0 inches (nominal design)
: g. Original Fuel Assembly Width:
4.70 inches (nominal design)
: h. Fuel Debris Weight:
550 lbs, including channels and DFC  


Approved Contents 2.0 Table 2.1-1 (page 9 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-15 Table 2.1-1 (page 9 of 30)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: 7. Thoria rods (ThO2 and UO2) placed in Dresden Unit 1 Thoria Rod Canisters and meeting the following specifications:
: 7. Thoria rods (ThO2 and UO2) placed in Dresden Unit 1 Thoria Rod Canisters and meeting the following specifications:
: a. Cladding Type:                         ZR
: a. Cladding Type:
: b. Composition:                           98.2 wt.% ThO2, 1.8 wt. % UO2 with an enrichment of 93.5 wt. % 235U.
ZR
: b. Composition:
98.2 wt.% ThO2, 1.8 wt. % UO2 with an enrichment of 93.5 wt. % 235U.
OR 98.5 wt.% ThO2, 1.5 wt.% UO2 with an enrichment of 93.5 wt.% 235U
OR 98.5 wt.% ThO2, 1.5 wt.% UO2 with an enrichment of 93.5 wt.% 235U
: c. Number of Rods Per Thoria Rod           18 Canister:
: c. Number of Rods Per Thoria Rod Canister:
: d. Decay Heat Per Thoria Rod               115 Watts Canister:
18
: e. Post-irradiation Fuel Cooling Time     A fuel post-irradiation cooling time 18 and Average Burnup Per Thoria        years and an average burnup 16,000 Rod Canister:                        MWD/MTIHM.
: d. Decay Heat Per Thoria Rod Canister:
: f. Initial Heavy Metal Weight:             27 kg/canister
115 Watts
: g. Fuel Cladding O.D.:                     0.412 inches
: e. Post-irradiation Fuel Cooling Time and Average Burnup Per Thoria Rod Canister:
: h. Fuel Cladding I.D.:                     0.362 inches
A fuel post-irradiation cooling time 18 years and an average burnup 16,000 MWD/MTIHM.
: i. Fuel Pellet O.D.:                       0.358 inches
: f. Initial Heavy Metal Weight:
: j. Active Fuel Length:                     111 inches
27 kg/canister
: k. Canister Weight:                       550 lbs, including fuel Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                  2-15
: g. Fuel Cladding O.D.:
0.412 inches
: h. Fuel Cladding I.D.:
0.362 inches
: i. Fuel Pellet O.D.:
0.358 inches
: j. Active Fuel Length:
111 inches
: k. Canister Weight:
550 lbs, including fuel  


Approved Contents 2.0 Table 2.1-1 (page 10 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-16 Table 2.1-1 (page 10 of 30)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)
B. Quantity per MPC (up to a total of 68 assemblies):
B. Quantity per MPC (up to a total of 68 assemblies):
Line 188: Line 244:
: 5. Up to one (1) Dresden Unit 1 Thoria Rod Canister.
: 5. Up to one (1) Dresden Unit 1 Thoria Rod Canister.
C. Fuel assemblies with stainless steel channels are not authorized for loading in the MPC-68F.
C. Fuel assemblies with stainless steel channels are not authorized for loading in the MPC-68F.
D. Dresden Unit 1 fuel assemblies with one Antimony-Beryllium neutron source are authorized for loading in the MPC-68F. The Antimony-Beryllium source material shall be in a water rod location.
D. Dresden Unit 1 fuel assemblies with one Antimony-Beryllium neutron source are authorized for loading in the MPC-68F. The Antimony-Beryllium source material shall be in a water rod location.  
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-16


Approved Contents 2.0 Table 2.1-1 (page 11 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-17 Table 2.1-1 (page 11 of 30)
Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF A. Allowable Contents
Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF A. Allowable Contents
: 1. Uranium oxide or MOX BWR INTACT FUEL ASSEMBLIES listed in Table 2.1-3, with or without channels and meeting the following specifications:
: 1. Uranium oxide or MOX BWR INTACT FUEL ASSEMBLIES listed in Table 2.1-3, with or without channels and meeting the following specifications:
: a. Cladding Type:                             ZR or Stainless Steel (SS) as specified in Table 2.1-3 for the applicable fuel assembly array/class
: a. Cladding Type:
: b. Maximum PLANAR-AVERAGE                     As specified in Table 2.1-3 for the INITIAL ENRICHMENT:                        applicable fuel assembly array/class.
ZR or Stainless Steel (SS) as specified in Table 2.1-3 for the applicable fuel assembly array/class
: c. Initial Maximum Rod Enrichment             As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:
As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: c. Initial Maximum Rod Enrichment As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly
: i. Array/Classes 6x6A, 6x6B,       Cooling time 18 years and an average 6x6C, 7x7A, and 8x8A            burnup 30,000 MWD/MTU (or MWD/MTIHM).
: i. Array/Classes 6x6A, 6x6B, 6x6C, 7x7A, and 8x8A Cooling time 18 years and an average burnup 30,000 MWD/MTU (or MWD/MTIHM).
ii. Array/Class 8x8F               Cooling time 10 years and an average burnup 27,500 MWD/MTU.
ii. Array/Class 8x8F Cooling time 10 years and an average burnup 27,500 MWD/MTU.
iii. Array/Classes 10x10D           Cooling time 10 years and an average and 10x10E                      burnup 22,500 MWD/MTU.
iii. Array/Classes 10x10D and 10x10E Cooling time 10 years and an average burnup 22,500 MWD/MTU.
iv. All Other Array/Classes         As specified in Section 2.4.
iv. All Other Array/Classes As specified in Section 2.4.  
Certificate of Compliance No. 1014                                            Amendment No. 12 Appendix B                                        2-17


Approved Contents 2.0 Table 2.1-1 (page 12 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-18 Table 2.1-1 (page 12 of 30)
Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)
Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: e. Decay Heat Per Assembly
: e. Decay Heat Per Assembly
: i. Array/Classes 6x6A, 6X6B,       115 Watts 6x6C, 7x7A, and 8x8A ii. Array/Class 8x8F               183.5 Watts iii. Array/Classes 10x10D         95 Watts and 10x10E iv. All Other Array/Classes       As specified in Section 2.4.
: i. Array/Classes 6x6A, 6X6B, 6x6C, 7x7A, and 8x8A 115 Watts ii. Array/Class 8x8F 183.5 Watts iii. Array/Classes 10x10D and 10x10E 95 Watts iv. All Other Array/Classes As specified in Section 2.4.
: f. Fuel Assembly Length
: f. Fuel Assembly Length
: i. Array/Class 6x6A, 6x6B,         135.0 inches (nominal design) 6x6C, 7x7A, or 8x8A ii. All Other Array/Classes       176.5 inches (nominal design)
: i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 135.0 inches (nominal design) ii. All Other Array/Classes 176.5 inches (nominal design)
: g. Fuel Assembly Width
: g. Fuel Assembly Width
: i. Array/Class 6x6A, 6x6B,         4.70 inches (nominal design) 6x6C, 7x7A, or 8x8A ii. All Other Array/Classes       5.85 inches (nominal design)
: i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 4.70 inches (nominal design) ii. All Other Array/Classes 5.85 inches (nominal design)
: h. Fuel Assembly Weight
: h. Fuel Assembly Weight
: i. Array/Class 6x6A, 6x6B,         400 lbs, including channels 6x6C, 7x7A, or 8x8A ii. All Other Array/Classes       730 lbs, including channels Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-18
: i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 400 lbs, including channels ii. All Other Array/Classes 730 lbs, including channels  


Approved Contents 2.0 Table 2.1-1 (page 13 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-19 Table 2.1-1 (page 13 of 30)
Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)
Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: 2. Uranium oxide or MOX BWR DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, with or without channels, placed in DAMAGED FUEL CONTAINERS.
: 2. Uranium oxide or MOX BWR DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, with or without channels, placed in DAMAGED FUEL CONTAINERS.
Uranium oxide and MOX BWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS shall meet the criteria specified in Table 2.1-3, and meet the following specifications:
Uranium oxide and MOX BWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS shall meet the criteria specified in Table 2.1-3, and meet the following specifications:
: a. Cladding Type:                           ZR or Stainless Steel (SS) in accordance with Table 2.1-3 for the applicable fuel assembly array/class.
: a. Cladding Type:
ZR or Stainless Steel (SS) in accordance with Table 2.1-3 for the applicable fuel assembly array/class.
: b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:
: b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:
: i. Array/Classes 6x6A, 6x6B,     As specified in Table 2.1-3 for the 6x6C, 7x7A, and 8x8A.          applicable fuel assembly array/class.
: i. Array/Classes 6x6A, 6x6B, 6x6C, 7x7A, and 8x8A.
ii. All Other Array Classes       4.0 wt.% 235U.
As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: c. Initial Maximum Rod Enrichment           As specified in Table 2.1-3 for the applicable fuel assembly array/class.
ii. All Other Array Classes 4.0 wt.% 235U.
: c. Initial Maximum Rod Enrichment As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: i. Array/Class 6x6A, 6x6B,       Cooling time 18 years and an average 6x6C, 7x7A, or 8x8A            burnup 30,000 MWD/MTU (or MWD/MTIHM).
: i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A Cooling time 18 years and an average burnup 30,000 MWD/MTU (or MWD/MTIHM).
ii. Array/Class 8x8F             Cooling time 10 years and an average burnup 27,500 MWD/MTU.
ii. Array/Class 8x8F Cooling time 10 years and an average burnup 27,500 MWD/MTU.
iii. Array/Class 10x10D and       Cooling time 10 years and an average 10x10E                        burnup 22,500 MWD/MTU.
iii. Array/Class 10x10D and 10x10E Cooling time 10 years and an average burnup 22,500 MWD/MTU.
iv. All Other Array/Classes       As specified in Section 2.4.
iv. All Other Array/Classes As specified in Section 2.4.  
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      2-19


Approved Contents 2.0 Table 2.1-1 (page 14 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-20 Table 2.1-1 (page 14 of 30)
Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)
Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: e. Decay Heat Per Assembly
: e. Decay Heat Per Assembly
: i. Array/Class 6x6A, 6x6B,         115 Watts 6x6C, 7x7A, or 8x8A ii. Array/Class 8x8F               183.5 Watts iii. Array/Classes 10x10D         95 Watts and 10x10E iv. All Other Array/Classes       As specified in Section 2.4.
: i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 115 Watts ii. Array/Class 8x8F 183.5 Watts iii. Array/Classes 10x10D and 10x10E 95 Watts iv. All Other Array/Classes As specified in Section 2.4.
: f. Fuel Assembly Length
: f. Fuel Assembly Length
: i. Array/Class 6x6A, 6x6B,         135.0 inches (nominal design) 6x6C, 7x7A, or 8x8A ii. All Other Array/Classes       176.5 inches (nominal design)
: i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 135.0 inches (nominal design) ii. All Other Array/Classes 176.5 inches (nominal design)
: g. Fuel Assembly Width
: g. Fuel Assembly Width
: i. Array/Class 6x6A, 6x6B,         4.70 inches (nominal design) 6x6C, 7x7A, or 8x8A ii. All Other Array/Classes       5.85 inches (nominal design)
: i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 4.70 inches (nominal design) ii. All Other Array/Classes 5.85 inches (nominal design)
: h. Fuel Assembly Weight
: h. Fuel Assembly Weight
: i. Array/Class 6x6A, 6x6B,         550 lbs, including channels and DFC 6x6C, 7x7A, or 8x8A ii. All Other Array/Classes       830 lbs, including channels and DFC Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-20
: i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 550 lbs, including channels and DFC ii. All Other Array/Classes 830 lbs, including channels and DFC  


Approved Contents 2.0 Table 2.1-1 (page 15 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-21 Table 2.1-1 (page 15 of 30)
Fuel Assembly limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)
Fuel Assembly limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: 3. Thoria rods (ThO2 and UO2) placed in Dresden Unit 1 Thoria Rod Canisters and meeting the following specifications:
: 3. Thoria rods (ThO2 and UO2) placed in Dresden Unit 1 Thoria Rod Canisters and meeting the following specifications:
: a. Cladding type                           ZR
: a. Cladding type ZR
: b. Composition                             98.2 wt.% ThO2, 1.8 wt.% UO2 with an enrichment of 93.5 wt.% 235U.
: b. Composition 98.2 wt.% ThO2, 1.8 wt.% UO2 with an enrichment of 93.5 wt.% 235U.
OR 98.5 wt.% ThO2, 1.5 wt.% UO2 with an enrichment of 93.5% wt.% 235U
OR 98.5 wt.% ThO2, 1.5 wt.% UO2 with an enrichment of 93.5% wt.% 235U
: c. Number of Rods per Thoria Rod           18 Canister:
: c. Number of Rods per Thoria Rod Canister:
: d. Decay Heat Per Thoria Rod               115 Watts Canister:
18
: e. Post-irradiation Fuel Cooling Time     A fuel post-irradiation cooling time 18 and Average Burnup per Thoria          years and an average burnup 16,000 Rod Canister:                          MWD/MTIHM
: d. Decay Heat Per Thoria Rod Canister:
: f. Initial Heavy Metal Weight:             27 kg/canister
115 Watts
: g. Fuel Cladding O.D.:                     0.412 inches
: e. Post-irradiation Fuel Cooling Time and Average Burnup per Thoria Rod Canister:
: h. Fuel Cladding I.D.:                     0.362 inches
A fuel post-irradiation cooling time 18 years and an average burnup 16,000 MWD/MTIHM
: i. Fuel Pellet O.D.:                       0.358 inches
: f. Initial Heavy Metal Weight:
: j. Active Fuel Length:                     111 inches
27 kg/canister
: k. Canister Weight:                         550 lbs, including fuel Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                  2-21
: g. Fuel Cladding O.D.:
0.412 inches
: h. Fuel Cladding I.D.:
0.362 inches
: i. Fuel Pellet O.D.:
0.358 inches
: j. Active Fuel Length:
111 inches
: k. Canister Weight:
550 lbs, including fuel  


Approved Contents 2.0 Table 2.1-1 (page 16 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-22 Table 2.1-1 (page 16 of 30)
Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)
Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)
B. Quantity per MPC (up to a total of 68 assemblies)
B. Quantity per MPC (up to a total of 68 assemblies)
Line 268: Line 334:
Up to eight (8) DFCs containing FUEL DEBRIS from these array/classes may be stored.
Up to eight (8) DFCs containing FUEL DEBRIS from these array/classes may be stored.
: 2. For all other array/classes, up to sixteen (16) DFCs containing BWR DAMAGED FUEL ASSEMBLIES and/or up to eight (8) DFCs containing FUEL DEBRIS. DFCs shall be located only in fuel storage locations 1, 2, 3, 8, 9, 16, 25, 34, 35, 44, 53, 60, 61, 66, 67, and/or 68. The remaining fuel storage locations may be filled with fuel assemblies of the following type:
: 2. For all other array/classes, up to sixteen (16) DFCs containing BWR DAMAGED FUEL ASSEMBLIES and/or up to eight (8) DFCs containing FUEL DEBRIS. DFCs shall be located only in fuel storage locations 1, 2, 3, 8, 9, 16, 25, 34, 35, 44, 53, 60, 61, 66, 67, and/or 68. The remaining fuel storage locations may be filled with fuel assemblies of the following type:
: i. Uranium Oxide BWR INTACT FUEL ASSEMBLIES; or ii. MOX BWR INTACT FUEL ASSEMBLIES.
: i.
Uranium Oxide BWR INTACT FUEL ASSEMBLIES; or ii.
MOX BWR INTACT FUEL ASSEMBLIES.
: 3. Up to one (1) Dresden Unit 1 Thoria Rod Canister C. Dresden Unit 1 fuel assemblies with one Antimony-Beryllium neutron source are authorized for loading. The Antimony-Beryllium source material shall be in a water rod location.
: 3. Up to one (1) Dresden Unit 1 Thoria Rod Canister C. Dresden Unit 1 fuel assemblies with one Antimony-Beryllium neutron source are authorized for loading. The Antimony-Beryllium source material shall be in a water rod location.
D. Array/Class 10x10D and 10x10E fuel assemblies in stainless steel channels must be stored in fuel storage locations 19 - 22, 28 - 31, 38 -41, and/or 47 -
D. Array/Class 10x10D and 10x10E fuel assemblies in stainless steel channels must be stored in fuel storage locations 19 - 22, 28 - 31, 38 -41, and/or 47 -
50 (see Figure 2.1-4).
50 (see Figure 2.1-4).  
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-22


Approved Contents 2.0 Table 2.1-1 (page 17 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-23 Table 2.1-1 (page 17 of 30)
Fuel Assembly Limits IV. MPC MODEL: MPC-24E and MPC-24EF A. Allowable Contents
Fuel Assembly Limits IV. MPC MODEL: MPC-24E and MPC-24EF A. Allowable Contents
: 1. Uranium oxide, PWR INTACT FUEL ASSEMBLIES listed in Table 2.1-2, with or without NON-FUEL HARDWARE and meeting the following specifications (Note 1):
: 1.
: a. Cladding Type:                       ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class
Uranium oxide, PWR INTACT FUEL ASSEMBLIES listed in Table 2.1-2, with or without NON-FUEL HARDWARE and meeting the following specifications (Note 1):
: b. Initial Enrichment:                   As specified in Table 2.1-2 for the applicable fuel assembly array/class.
: a. Cladding Type:
ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class
: b. Initial Enrichment:
As specified in Table 2.1-2 for the applicable fuel assembly array/class.
: c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: i. Array/Classes 14x14D,         Cooling time 8 years and an average 14x14E, and 15x15G            burnup 40,000 MWD/MTU.
: i. Array/Classes 14x14D, 14x14E, and 15x15G Cooling time 8 years and an average burnup 40,000 MWD/MTU.
ii. All Other Array/Classes       As specified in Section 2.4.
ii. All Other Array/Classes As specified in Section 2.4.
iii. NON-FUEL HARDWARE           As specified in Table 2.1-8.
iii. NON-FUEL HARDWARE As specified in Table 2.1-8.  
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                    2-23


Approved Contents 2.0 Table 2.1-1 (page 18 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-24 Table 2.1-1 (page 18 of 30)
Fuel Assembly Limits IV. MPC MODEL: MPC-24E and MPC-24EF (continued)
Fuel Assembly Limits IV. MPC MODEL: MPC-24E and MPC-24EF (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: d. Decay Heat Per Fuel Storage Location:
: d. Decay Heat Per Fuel Storage Location:
: i. Array/Classes 14x14D,           710 Watts.
: i. Array/Classes 14x14D, 14x14E, and 15x15G 710 Watts.
14x14E, and 15x15G ii. All other Array/Classes       As specified in Section 2.4.
ii. All other Array/Classes As specified in Section 2.4.
: e. Fuel Assembly Length:                 176.8 inches (nominal design)
: e. Fuel Assembly Length:
: f. Fuel Assembly Width:                 8.54 inches (nominal design)
176.8 inches (nominal design)
: g. Fuel Assembly Weight:                 1,720 lbs (including NON-FUEL HARDWARE) for assemblies that do not require fuel spacers, otherwise, 1,680 lbs (including NON-FUEL HARDWARE)
: f. Fuel Assembly Width:
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-24
8.54 inches (nominal design)
: g. Fuel Assembly Weight:
1,720 lbs (including NON-FUEL HARDWARE) for assemblies that do not require fuel spacers, otherwise, 1,680 lbs (including NON-FUEL HARDWARE)  


Approved Contents 2.0 Table 2.1-1 (page 19 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-25 Table 2.1-1 (page 19 of 30)
Fuel Assembly Limits IV. MPC MODEL: MPC-24E and MPC-24EF (continued)
Fuel Assembly Limits IV. MPC MODEL: MPC-24E and MPC-24EF (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: 2. Uranium oxide, PWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS, with or without NON-FUEL HARDWARE, placed in DAMAGED FUEL CONTAINERS.
: 2. Uranium oxide, PWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS, with or without NON-FUEL HARDWARE, placed in DAMAGED FUEL CONTAINERS.
Uranium oxide PWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS shall meet the criteria specified in Table 2.1-2 and meet the following specifications (Note 1):
Uranium oxide PWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS shall meet the criteria specified in Table 2.1-2 and meet the following specifications (Note 1):
: a. Cladding Type:                       ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class
: a. Cladding Type:
: b. Initial Enrichment:                   As specified in Table 2.1-2 for the applicable fuel assembly array/class.
ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class
: b. Initial Enrichment:
As specified in Table 2.1-2 for the applicable fuel assembly array/class.
: c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: i. Array/Classes 14x14D,         Cooling time 8 years and an average 14x14E, and 15x15G            burnup 40,000 MWD/MTU.
: i. Array/Classes 14x14D, 14x14E, and 15x15G Cooling time 8 years and an average burnup 40,000 MWD/MTU.
ii. All Other Array/Classes       As specified in Section 2.4.
ii. All Other Array/Classes As specified in Section 2.4.
iii. NON-FUEL HARDWARE           As specified in Table 2.1-8.
iii. NON-FUEL HARDWARE As specified in Table 2.1-8.  
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                    2-25


Approved Contents 2.0 Table 2.1-1 (page 20 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-26 Table 2.1-1 (page 20 of 30)
Fuel Assembly Limits IV. MPC MODEL: MPC-24E and MPC-24EF (continued)
Fuel Assembly Limits IV. MPC MODEL: MPC-24E and MPC-24EF (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: d. Decay Heat Per Fuel Storage Location:
: d. Decay Heat Per Fuel Storage Location:
: i. Array/Classes 14x14D,           710 Watts.
: i. Array/Classes 14x14D, 14x14E, and 15x15G 710 Watts.
14x14E, and 15x15G ii. All Other Array/Classes       As specified in Section 2.4.
ii. All Other Array/Classes As specified in Section 2.4.
: e. Fuel Assembly Length                 176.8 inches (nominal design)
: e. Fuel Assembly Length 176.8 inches (nominal design)
: f. Fuel Assembly Width                   8.54 inches (nominal design)
: f. Fuel Assembly Width 8.54 inches (nominal design)
: g. Fuel Assembly Weight                 1,720 lbs (including NON-FUEL HARDWARE and DFC) for assemblies that do not require fuel spacers, otherwise, 1,680 lbs (including NON-FUEL HARDWARE and DFC)
: g. Fuel Assembly Weight 1,720 lbs (including NON-FUEL HARDWARE and DFC) for assemblies that do not require fuel spacers, otherwise, 1,680 lbs (including NON-FUEL HARDWARE and DFC)
B. Quantity per MPC: Up to four (4) DAMAGED FUEL ASSEMBLIES and/or FUEL DEBRIS in DAMAGED FUEL CONTAINERS, stored in fuel storage locations 3, 6, 19 and/or 22. The remaining fuel storage locations may be filled with PWR INTACT FUEL ASSEMBLIES meeting the applicable specifications.
B. Quantity per MPC: Up to four (4) DAMAGED FUEL ASSEMBLIES and/or FUEL DEBRIS in DAMAGED FUEL CONTAINERS, stored in fuel storage locations 3, 6, 19 and/or 22. The remaining fuel storage locations may be filled with PWR INTACT FUEL ASSEMBLIES meeting the applicable specifications.
C. One NSA is permitted for loading.
C. One NSA is permitted for loading.
Note 1: Fuel assemblies containing BPRAs, TPDs, WABAs, water displacement guide tube plugs, orifice rod assemblies, or vibration suppressor inserts, with or without ITTRs, may be stored in any fuel storage location. Fuel assemblies containing APSRs or NSAs may only be loaded in fuel storage locations 9, 10, 15, and/or 16 (see Figure 2.1-2). Fuel assemblies containing CRAs, RCCAs, or CEAs may only be stored in fuel storage locations 4, 5, 8 - 11, 14 - 17, 20 and/or 21 (see Figure 2.1-2). These requirements are in addition to any other requirements specified for uniform or regionalized fuel loading.
Note 1: Fuel assemblies containing BPRAs, TPDs, WABAs, water displacement guide tube plugs, orifice rod assemblies, or vibration suppressor inserts, with or without ITTRs, may be stored in any fuel storage location. Fuel assemblies containing APSRs or NSAs may only be loaded in fuel storage locations 9, 10, 15, and/or 16 (see Figure 2.1-2). Fuel assemblies containing CRAs, RCCAs, or CEAs may only be stored in fuel storage locations 4, 5, 8 - 11, 14 - 17, 20 and/or 21 (see Figure 2.1-2). These requirements are in addition to any other requirements specified for uniform or regionalized fuel loading.  
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                    2-26


Approved Contents 2.0 Table 2.1-1 (page 21 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-27 Table 2.1-1 (page 21 of 30)
Fuel Assembly Limits V. MPC MODEL: MPC-32 and MPC-32F A. Allowable Contents
Fuel Assembly Limits V. MPC MODEL: MPC-32 and MPC-32F A. Allowable Contents
: 1.     Uranium oxide, PWR INTACT FUEL ASSEMBLIES listed in Table 2.1-2, with or without NON-FUEL HARDWARE and meeting the following specifications (Note 1):
: 1.
: a. Cladding Type:                           ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class
Uranium oxide, PWR INTACT FUEL ASSEMBLIES listed in Table 2.1-2, with or without NON-FUEL HARDWARE and meeting the following specifications (Note 1):
: b. Initial Enrichment:                       As specified in Table 2.1-2 for the applicable fuel assembly array/class.
: a. Cladding Type:
ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class
: b. Initial Enrichment:
As specified in Table 2.1-2 for the applicable fuel assembly array/class.
: c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: i. Array/Classes 14x14D,         Cooling time 9 years and an average 14x14E, and 15x15G            burnup 30,000 MWD/MTU or cooling time 20 years and an average burnup 40,000 MWD/MTU.
: i. Array/Classes 14x14D, 14x14E, and 15x15G Cooling time 9 years and an average burnup 30,000 MWD/MTU or cooling time 20 years and an average burnup 40,000 MWD/MTU.
ii. All Other Array/Classes       As specified in Section 2.4.
ii. All Other Array/Classes As specified in Section 2.4.
iii. NON-FUEL HARDWARE           As specified in Table 2.1-8.
iii. NON-FUEL HARDWARE As specified in Table 2.1-8.  
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      2-27


Approved Contents 2.0 Table 2.1-1 (page 22 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-28 Table 2.1-1 (page 22 of 30)
Fuel Assembly Limits V. MPC MODEL: MPC-32 and MPC-32F (contd)
Fuel Assembly Limits V. MPC MODEL: MPC-32 and MPC-32F (contd)
A. Allowable Contents (contd)
A. Allowable Contents (contd)
: d. Decay Heat Per Fuel Storage Location:
: d. Decay Heat Per Fuel Storage Location:
: i. Array/Classes 14x14D,           500 Watts.
: i. Array/Classes 14x14D, 14x14E, and 15x15G 500 Watts.
14x14E, and 15x15G ii. All Other Array/Classes       As specified in Section 2.4.
ii. All Other Array/Classes As specified in Section 2.4.
: e. Fuel Assembly Length                 176.8 inches (nominal design)
: e. Fuel Assembly Length 176.8 inches (nominal design)
: f. Fuel Assembly Width                   8.54 inches (nominal design)
: f. Fuel Assembly Width 8.54 inches (nominal design)
: g. Fuel Assembly Weight                 1,720 lbs (including NON-FUEL HARDWARE) for assemblies that do not require fuel spacers, otherwise, 1,680 lbs (including NON-FUEL HARDWARE)
: g. Fuel Assembly Weight 1,720 lbs (including NON-FUEL HARDWARE) for assemblies that do not require fuel spacers, otherwise, 1,680 lbs (including NON-FUEL HARDWARE)  
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-28


Approved Contents 2.0 Table 2.1-1 (page 23 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-29 Table 2.1-1 (page 23 of 30)
Fuel Assembly Limits V. MPC MODEL: MPC-32 and MPC-32F (contd)
Fuel Assembly Limits V. MPC MODEL: MPC-32 and MPC-32F (contd)
A. Allowable Contents (contd)
A. Allowable Contents (contd)
: 2. Uranium oxide, PWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS, with or without NON-FUEL HARDWARE, placed in DAMAGED FUEL CONTAINERS. Uranium oxide PWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS shall meet the criteria specified in Table 2.1-2 and meet the following specifications (Note 1):
: 2.
: a. Cladding Type:                           ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class
Uranium oxide, PWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS, with or without NON-FUEL HARDWARE, placed in DAMAGED FUEL CONTAINERS. Uranium oxide PWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS shall meet the criteria specified in Table 2.1-2 and meet the following specifications (Note 1):
: b. Initial Enrichment:                       As specified in Table 2.1-2 for the applicable fuel assembly array/class.
: a. Cladding Type:
ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class
: b. Initial Enrichment:
As specified in Table 2.1-2 for the applicable fuel assembly array/class.
: c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: i. Array/Classes 14x14D,         Cooling time 9 years and an average 14x14E, and 15x15G            burnup 30,000 MWD/MTU or cooling time 20 years and an average burnup 40,000 MWD/MTU.
: i. Array/Classes 14x14D, 14x14E, and 15x15G Cooling time 9 years and an average burnup 30,000 MWD/MTU or cooling time 20 years and an average burnup 40,000 MWD/MTU.
ii. All Other Array/Classes       As specified in Section 2.4.
ii. All Other Array/Classes As specified in Section 2.4.
iii. NON-FUEL HARDWARE           As specified in Table 2.1-8.
iii. NON-FUEL HARDWARE As specified in Table 2.1-8.  
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      2-29


Approved Contents 2.0 Table 2.1-1 (page 24 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-30 Table 2.1-1 (page 24 of 30)
Fuel Assembly Limits V. MPC MODEL: MPC-32 and MPC-32F (contd)
Fuel Assembly Limits V. MPC MODEL: MPC-32 and MPC-32F (contd)
A. Allowable Contents (contd)
A. Allowable Contents (contd)
: d. Decay Heat Per Fuel Storage Location:
: d. Decay Heat Per Fuel Storage Location:
: i. Array/Classes 14x14D,           500 Watts.
: i. Array/Classes 14x14D, 14x14E, and 15x15G 500 Watts.
14x14E, and 15x15G ii. All Other Array/Classes       As specified in Section 2.4.
ii. All Other Array/Classes As specified in Section 2.4.
: e. Fuel Assembly Length                   176.8 inches (nominal design)
: e. Fuel Assembly Length 176.8 inches (nominal design)
: f. Fuel Assembly Width                   8.54 inches (nominal design)
: f. Fuel Assembly Width 8.54 inches (nominal design)
: g. Fuel Assembly Weight                   1,720 lbs (including NON-FUEL HARDWARE and DFC) for assemblies that do not require fuel spacers, otherwise, 1,680 lbs (including NON-FUEL HARDWARE and DFC)
: g. Fuel Assembly Weight 1,720 lbs (including NON-FUEL HARDWARE and DFC) for assemblies that do not require fuel spacers, otherwise, 1,680 lbs (including NON-FUEL HARDWARE and DFC)
B.       Quantity per MPC: Up to eight (8) DAMAGED FUEL ASSEMBLIES and/or FUEL DEBRIS in DAMAGED FUEL CONTAINERS, stored in fuel storage locations 1, 4, 5, 10, 23, 28, 29, and/or 32. The remaining fuel storage locations may be filled with PWR INTACT FUEL ASSEMBLIES meeting the applicable specifications.
B. Quantity per MPC: Up to eight (8) DAMAGED FUEL ASSEMBLIES and/or FUEL DEBRIS in DAMAGED FUEL CONTAINERS, stored in fuel storage locations 1, 4, 5, 10, 23, 28, 29, and/or 32. The remaining fuel storage locations may be filled with PWR INTACT FUEL ASSEMBLIES meeting the applicable specifications.
C.         One NSA is permitted for loading.
C.
Note 1: Fuel assemblies containing BPRAs, TPDs, WABAs, water displacement guide tube plugs, orifice rod assemblies, or vibration suppressor inserts, with or without ITTRs, may be stored in any fuel storage location. Fuel assemblies containing NSAs may only be loaded in fuel storage locations 13, 14, 19 and/or 20 (see Figure 2.1-3). Fuel assemblies containing CRAs, RCCAs, CEAs or APSRs may only be loaded in fuel storage locations 7, 8, 12-15, 18-21, 25 and/or 26 (see Figure 2.1-3). These requirements are in addition to any other requirements specified for uniform or regionalized fuel loading.
One NSA is permitted for loading.
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                    2-30
Note 1: Fuel assemblies containing BPRAs, TPDs, WABAs, water displacement guide tube plugs, orifice rod assemblies, or vibration suppressor inserts, with or without ITTRs, may be stored in any fuel storage location. Fuel assemblies containing NSAs may only be loaded in fuel storage locations 13, 14, 19 and/or 20 (see Figure 2.1-3). Fuel assemblies containing CRAs, RCCAs, CEAs or APSRs may only be loaded in fuel storage locations 7, 8, 12-15, 18-21, 25 and/or 26 (see Figure 2.1-3). These requirements are in addition to any other requirements specified for uniform or regionalized fuel loading.  


Approved Contents 2.0 Table 2.1-1 (page 25 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-31 Table 2.1-1 (page 25 of 30)
Fuel Assembly Limits VI. MPC MODEL: MPC-68M A. Allowable Contents
Fuel Assembly Limits VI. MPC MODEL: MPC-68M A. Allowable Contents
: 1. Uranium oxide BWR UNDAMAGED FUEL ASSEMBLIES listed in Table 2.1-3, with or without channels and meeting the following specifications:
: 1. Uranium oxide BWR UNDAMAGED FUEL ASSEMBLIES listed in Table 2.1-3, with or without channels and meeting the following specifications:
: a. Cladding Type:                           ZR
: a. Cladding Type:
: b. Maximum PLANAR-AVERAGE                   As specified in Table 2.1-3 for the INITIAL ENRICHMENT:                      applicable fuel assembly array/class.
ZR
: c. Initial Maximum Rod Enrichment           As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:
As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: c. Initial Maximum Rod Enrichment As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly
: i. Array/Class 8x8F               Cooling time 10 years and an average burnup 27,500 MWD/MTU.
: i. Array/Class 8x8F Cooling time 10 years and an average burnup 27,500 MWD/MTU.
ii. All Other Array/Classes       As specified in Section 2.4.
ii. All Other Array/Classes As specified in Section 2.4.  
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      2-31


Approved Contents 2.0 Table 2.1-1 (page 26 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-32 Table 2.1-1 (page 26 of 30)
Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)
Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: e. Decay Heat Per Assembly
: e. Decay Heat Per Assembly
: i. Array/Class 8x8F               183.5 Watts ii. All Other Array/Classes       As specified in Section 2.4.
: i. Array/Class 8x8F 183.5 Watts ii. All Other Array/Classes As specified in Section 2.4.
: f. Fuel Assembly Length                     176.5 inches (nominal design)
: f. Fuel Assembly Length 176.5 inches (nominal design)
: g. Fuel Assembly Width                     5.85 inches (nominal design)
: g. Fuel Assembly Width 5.85 inches (nominal design)
: h. Fuel Assembly Weight                     730 lbs, including channels Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-32
: h. Fuel Assembly Weight 730 lbs, including channels  


Approved Contents 2.0 Table 2.1-1 (page 27 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-33 Table 2.1-1 (page 27 of 30)
Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)
Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: 2. Uranium oxide BWR DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, with or without channels, placed in DAMAGED FUEL CONTAINERS. Uranium oxide BWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS shall meet the criteria specified in Table 2.1-3, and meet the following specifications:
: 2. Uranium oxide BWR DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, with or without channels, placed in DAMAGED FUEL CONTAINERS. Uranium oxide BWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS shall meet the criteria specified in Table 2.1-3, and meet the following specifications:
: a. Cladding Type:                           ZR
: a. Cladding Type:
: b. Maximum PLANAR-AVERAGE                   As specified in Table 2.1-3 for the INITIAL ENRICHMENT:                      applicable fuel assembly array/class.
ZR
: c. Initial Maximum Rod Enrichment           As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:
As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: c. Initial Maximum Rod Enrichment As specified in Table 2.1-3 for the applicable fuel assembly array/class.
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: d. Post-irradiation Cooling Time and Average Burnup Per Assembly:
: i. Array/Class 8x8F               Cooling time 10 years and an average burnup 27,500 MWD/MTU.
: i. Array/Class 8x8F Cooling time 10 years and an average burnup 27,500 MWD/MTU.
ii. All Other Array/Classes       As specified in Section 2.4.
ii. All Other Array/Classes As specified in Section 2.4.  
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      2-33


Approved Contents 2.0 Table 2.1-1 (page 28 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-34 Table 2.1-1 (page 28 of 30)
Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)
Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: e. Decay Heat Per Assembly
: e. Decay Heat Per Assembly
: i. Array/Class 8x8F               183.5 Watts ii. All Other Array/Classes       As specified in Section 2.4.
: i. Array/Class 8x8F 183.5 Watts ii. All Other Array/Classes As specified in Section 2.4.
: f. Fuel Assembly Length                     176.5 inches (nominal design)
: f. Fuel Assembly Length 176.5 inches (nominal design)
: g. Fuel Assembly Width                     5.85 inches (nominal design)
: g. Fuel Assembly Width 5.85 inches (nominal design)
: h. Fuel Assembly Weight                     830 lbs, including channels and DFC Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-34
: h. Fuel Assembly Weight 830 lbs, including channels and DFC  


Approved Contents 2.0 Table 2.1-1 (page 29 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-35 Table 2.1-1 (page 29 of 30)
Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)
Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)
A. Allowable Contents (continued)
A. Allowable Contents (continued)
: 3. Thoria rods (ThO2 and UO2) placed in Dresden Unit 1 Thoria Rod Canisters and meeting the following specifications:
: 3. Thoria rods (ThO2 and UO2) placed in Dresden Unit 1 Thoria Rod Canisters and meeting the following specifications:
: a. Cladding Type:                         ZR
: a. Cladding Type:
: b. Composition                           98.2 wt.% ThO2, 1.8 wt.% UO2 with an 235 enrichment of 93.5 wt.%       U OR 98.5 wt.% ThO2, 1.5 wt.% UO2 with an 235 enrichment of 93.5% wt.%       U
ZR
: c. Number of Rods per Thoria Rod           18 Canister:
: b. Composition 98.2 wt.% ThO2, 1.8 wt.% UO2 with an enrichment of 93.5 wt.%
: d. Decay Heat Per Thoria Rod               115 Watts Canister:
235U OR 98.5 wt.% ThO2, 1.5 wt.% UO2 with an enrichment of 93.5% wt.%
: e. Post-irradiation Fuel Cooling Time     A fuel post-irradiation cooling time 18 and Average Burnup per Thoria          years and an average burnup 16,000 Rod Canister:                          MWD/MTIHM
235U
: f. Initial Heavy Metal Weight:             27 kg/canister
: c. Number of Rods per Thoria Rod Canister:
: g. Fuel Cladding O.D.:                     0.412 inches
18
: h. Fuel Cladding I.D.:                     0.362 inches
: d. Decay Heat Per Thoria Rod Canister:
: i. Fuel Pellet O.D.:                       0.358 inches
115 Watts
: j. Active Fuel Length:                     111 inches
: e. Post-irradiation Fuel Cooling Time and Average Burnup per Thoria Rod Canister:
: k. Canister Weight:                         550 lbs, including fuel Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                    2-35
A fuel post-irradiation cooling time 18 years and an average burnup 16,000 MWD/MTIHM
: f. Initial Heavy Metal Weight:
27 kg/canister
: g. Fuel Cladding O.D.:
0.412 inches
: h. Fuel Cladding I.D.:
0.362 inches
: i. Fuel Pellet O.D.:
0.358 inches
: j. Active Fuel Length:
111 inches
: k. Canister Weight:
550 lbs, including fuel  


Approved Contents 2.0 Table 2.1-1 (page 30 of 30)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-36 Table 2.1-1 (page 30 of 30)
Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)
Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)
B. Quantity per MPC (up to a total of 68 assemblies)
B. Quantity per MPC (up to a total of 68 assemblies)
: 1. Up to sixteen (16) DFCs containing BWR DAMAGED FUEL ASSEMBLIES and/or up to eight (8) DFCs containing FUEL DEBRIS. DFCs shall be located only in fuel storage locations 1, 2, 3, 8, 9, 16, 25, 34, 35, 44, 53, 60, 61, 66, 67, and/or 68. The remaining fuel storage locations may be filled with Uranium Oxide BWR UNDAMAGED FUEL ASSEMBLIES.
: 1. Up to sixteen (16) DFCs containing BWR DAMAGED FUEL ASSEMBLIES and/or up to eight (8) DFCs containing FUEL DEBRIS. DFCs shall be located only in fuel storage locations 1, 2, 3, 8, 9, 16, 25, 34, 35, 44, 53, 60, 61, 66, 67, and/or 68. The remaining fuel storage locations may be filled with Uranium Oxide BWR UNDAMAGED FUEL ASSEMBLIES.
: 2. Up to one (1) Dresden Unit 1 Thoria Rod Canister.
: 2. Up to one (1) Dresden Unit 1 Thoria Rod Canister.  
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                    2-36


Approved Contents 2.0 Table 2.1-2 (page 1 of 5)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-37 Table 2.1-2 (page 1 of 5)
PWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
PWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
Fuel Assembly 14x14A       14x14B       14x14C     14x14D       14x14E Array/Class Clad Material             ZR           ZR           ZR         SS           SS Design Initial U 365          412          438      400        206 (kg/assy.) (Note 3)
Fuel Assembly Array/Class 14x14A 14x14B 14x14C 14x14D 14x14E Clad Material ZR ZR ZR SS SS Design Initial U (kg/assy.) (Note 3) 365 412 438 400 206 Initial Enrichment (MPC-24, 24E and 24EF without soluble boron credit) (wt % 235U)
Initial Enrichment (MPC-24, 24E and       4.6 (24)     4.6 (24)   4.6 (24)   4.0 (24)   5.0 (24) 24EF without soluble boron              5.0          5.0        5.0      5.0         5.0 credit) (wt % 235U)  (24E/24EF)   (24E/24EF)   (24E/24EF) (24E/24EF)   (24E/24EF)
(Note 7) 4.6 (24) 5.0 (24E/24EF) 4.6 (24) 5.0 (24E/24EF) 4.6 (24) 5.0 (24E/24EF) 4.0 (24) 5.0 (24E/24EF) 5.0 (24) 5.0 (24E/24EF)
(Note 7)
Initial Enrichment (MPC-24, 24E, 24EF, 32, or 32F with soluble boron credit - see Note 5)
Initial Enrichment (MPC-24, 24E, 24EF, 32, or 32F 5.0         5.0         5.0       5.0         5.0 with soluble boron credit - see Note 5)
(wt % 235U) 5.0 5.0 5.0 5.0 5.0 No. of Fuel Rod Locations (Note 11) 179 179 176 180 173 Fuel Rod Clad O.D. (in.)
(wt % 235U)
0.400 0.417 0.440 0.422 0.3415 Fuel Rod Clad I.D.
No. of Fuel Rod Locations                 179           179           176       180         173 (Note 11)
(in.)
Fuel Rod Clad 0.400       0.417       0.440     0.422       0.3415 O.D. (in.)
0.3514 0.3734 0.3880 0.3890 0.3175 Fuel Pellet Dia.
Fuel Rod Clad I.D.
(in.)(Note 8) 0.3444 0.3659 0.3805 0.3835 0.3130 Fuel Rod Pitch (in.)
0.3514       0.3734     0.3880   0.3890       0.3175 (in.)
0.556 0.556 0.580 0.556 Note 6 Active Fuel Length (in.)
Fuel Pellet Dia.
150 150 150 144 102 No. of Guide and/or Instrument Tubes 17 17 5 (Note 4) 16 0
0.3444       0.3659     0.3805   0.3835       0.3130 (in.)(Note 8)
Guide/Instrument Tube Thickness (in.)
Fuel Rod Pitch (in.)     0.556       0.556       0.580     0.556       Note 6 Active Fuel Length 150         150         150       144         102 (in.)
0.017 0.017 0.038 0.0145 N/A  
No. of Guide and/or Instrument         17           17       5 (Note 4)     16           0 Tubes Guide/Instrument Tube Thickness           0.017       0.017       0.038   0.0145       N/A (in.)
Certificate of Compliance No. 1014                                    Amendment No. 12 Appendix B                                    2-37


Approved Contents 2.0 Table 2.1-2 (page 2 of 5)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-38 Table 2.1-2 (page 2 of 5)
PWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
PWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
Fuel Assembly 15x15A     15x15B       15x15C     15x15D     15x15E     15x15F Array/Class Clad Material           ZR         ZR           ZR         ZR         ZR         ZR Design Initial U
Fuel Assembly Array/Class 15x15A 15x15B 15x15C 15x15D 15x15E 15x15F Clad Material ZR ZR ZR ZR ZR ZR Design Initial U (kg/assy.) (Note 3)
                          < 473       < 473       < 473       < 495       < 495       < 495 (kg/assy.) (Note 3)
< 473  
Initial Enrichment (MPC-24, 24E and     < 4.1 (24) < 4.1 (24)   < 4.1 (24) < 4.1 (24) < 4.1 (24) < 4.1 (24) 24EF without soluble boron credit)                 < 4.5      < 4.5         < 4.5      < 4.5       < 4.5      < 4.5 (wt % 235U)          (24E/24EF)  (24E/24EF)  (24E/24EF)  (24E/24EF)  (24E/24EF)  (24E/24EF)
< 473  
(Note 7)
< 473  
Initial Enrichment (MPC-24, 24E, 24EF, 32, or 32F
< 495  
                          < 5.0       < 5.0         < 5.0     < 5.0       < 5.0       < 5.0 with soluble boron credit - see Note 5)(wt % 235U)
< 495  
No. of Fuel Rod Locations               204         204           204       208         208         208 (Note 11)
< 495 Initial Enrichment (MPC-24, 24E and 24EF without soluble boron credit)
Fuel Rod Clad
(wt % 235U)
                        > 0.418     > 0.420     > 0.417     > 0.430     > 0.428     > 0.428 O.D. (in.)
(Note 7)
Fuel Rod Clad I.D.
< 4.1 (24)  
                        < 0.3660   < 0.3736     < 0.3640   < 0.3800   < 0.3790   < 0.3820 (in.)
< 4.5 (24E/24EF)  
Fuel Pellet Dia.
< 4.1 (24)  
                        < 0.3580   < 0.3671     < 0.3570   < 0.3735   < 0.3707   < 0.3742 (in.) (Note 8)
< 4.5 (24E/24EF)  
Fuel Rod Pitch
< 4.1 (24)  
                        < 0.550     < 0.563     < 0.563     < 0.568     < 0.568     < 0.568 (in.)
< 4.5 (24E/24EF)  
Active Fuel Length
< 4.1 (24)
                          < 150       < 150       < 150       < 150       < 150       < 150 (in.)
< 4.5 (24E/24EF)
No. of Guide and/or Instrument         21         21           21         17         17         17 Tubes Guide/Instrument Tube Thickness       > 0.0165     > 0.015     > 0.0165   > 0.0150   > 0.0140   > 0.0140 (in.)
< 4.1 (24)
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-38
< 4.5 (24E/24EF)
< 4.1 (24)
< 4.5 (24E/24EF)
Initial Enrichment (MPC-24, 24E, 24EF, 32, or 32F with soluble boron credit - see Note 5)(wt % 235U)
< 5.0  
< 5.0  
< 5.0  
< 5.0  
< 5.0  
< 5.0 No. of Fuel Rod Locations (Note 11) 204 204 204 208 208 208 Fuel Rod Clad O.D. (in.)
> 0.418  
> 0.420  
> 0.417  
> 0.430  
> 0.428  
> 0.428 Fuel Rod Clad I.D.
(in.)  
< 0.3660  
< 0.3736  
< 0.3640  
< 0.3800  
< 0.3790  
< 0.3820 Fuel Pellet Dia.
(in.) (Note 8)  
< 0.3580  
< 0.3671  
< 0.3570  
< 0.3735  
< 0.3707  
< 0.3742 Fuel Rod Pitch (in.)  
< 0.550  
< 0.563  
< 0.563  
< 0.568  
< 0.568  
< 0.568 Active Fuel Length (in.)  
< 150  
< 150  
< 150  
< 150  
< 150  
< 150 No. of Guide and/or Instrument Tubes 21 21 21 17 17 17 Guide/Instrument Tube Thickness (in.)
> 0.0165  
> 0.015  
> 0.0165  
> 0.0150  
> 0.0140  
> 0.0140  


Approved Contents 2.0 Table 2.1-2 (page 3 of 5)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-39 Table 2.1-2 (page 3 of 5)
PWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
PWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
Fuel Assembly                             15x15I 15x15G   15x15H               16x16A     16x16B     16x16C Array/ Class Clad Material         SS       ZR           ZR       ZR         ZR       ZR Design Initial U                           495
Fuel Assembly Array/ Class 15x15G 15x15H 15x15I 16x16A 16x16B 16x16C Clad Material SS ZR ZR ZR ZR ZR Design Initial U (kg/assy.)(Note 3)
                            < 420     < 495                 < 448     < 427     < 426 (kg/assy.)(Note 3)
< 420  
Initial Enrichment  < 4.0                 N/A
< 495 495
                                    < 3.8 (24)           < 4.6 (24) < 4.6 (24) < 4.6 (24)
< 448  
(24)                (Note 9)
< 427  
(MPC-24, 24E, and 24EF without soluble boron                < 4.2                  < 5.0     < 5.0    < 5.0
< 426 Initial Enrichment (MPC-24, 24E, and 24EF without soluble boron credit)(wt % 235U)
                            < 4.5 credit)(wt % 235U)         (24E/24E              (24E/24E  (24E/24E   (24E/24E (24E/24 (Note 7)                        F)                    F)        F)        F)
(Note 7)  
EF)
< 4.0 (24)  
Initial Enrichment                         5.0 (MPC-24, 24E,                           (Note 9) 24EF, 32, or 32F with soluble         < 5.0   < 5.0                 < 5.0     < 5.0     < 5.0 boron credit - see Note 5) (wt %
< 4.5 (24E/24 EF)  
235U)
< 3.8 (24)  
No. of Fuel Rod                             216 Locations             204     208                   236       236       235 (Note 11)
< 4.2 (24E/24E F)
Fuel Rod Clad                             0.413
N/A (Note 9)  
                          > 0.422   > 0.414               > 0.382   > 0.374   > 0.374 O.D. (in.)
< 4.6 (24)
Fuel Rod Clad          <                  0.367
< 5.0 (24E/24E F)
                                    < 0.3700             < 0.3350   < 0.3290   < 0.3290 I.D. (in.)         0.3890 Fuel Pellet Dia.       <                  0.360
< 4.6 (24)
                                    < 0.3622              < 0.3255   < 0.3225   < 0.3225 (in.) (Note 8)      0.3825 Fuel Rod Pitch                            0.550
< 5.0 (24E/24E F)
                          < 0.563   < 0.568               < 0.506   < 0.506   < 0.485 (in.)
< 4.6 (24)  
Active Fuel                                150
< 5.0 (24E/24E F)
                            < 144     < 150                 < 150     < 150     < 150 Length (in.)
Initial Enrichment (MPC-24, 24E, 24EF, 32, or 32F with soluble boron credit - see Note 5) (wt %
No. of Guide                                 9 and/or Instrument     21       17     (Note 10) 5 (Note 4) 5 (Note 4)     21 Tubes Guide/Instrument                         0.0140 Tube Thickness              > 0.0140             > 0.0350   > 0.0400   > 0.0157 0.0145 (in.)
235U)
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                    2-39
< 5.0  
< 5.0 5.0 (Note 9)
< 5.0  
< 5.0  
< 5.0 No. of Fuel Rod Locations (Note 11) 204 208 216 236 236 235 Fuel Rod Clad O.D. (in.)
> 0.422  
> 0.414 0.413
> 0.382  
> 0.374  
> 0.374 Fuel Rod Clad I.D. (in.)
0.3890
< 0.3700 0.367
< 0.3350  
< 0.3290  
< 0.3290 Fuel Pellet Dia.
(in.) (Note 8) 0.3825
< 0.3622 0.360  
< 0.3255  
< 0.3225  
< 0.3225 Fuel Rod Pitch (in.)  
< 0.563  
< 0.568 0.550
< 0.506  
< 0.506  
< 0.485 Active Fuel Length (in.)  
< 144  
< 150 150
< 150  
< 150  
< 150 No. of Guide and/or Instrument Tubes 21 17 9
(Note 10) 5 (Note 4) 5 (Note 4) 21 Guide/Instrument Tube Thickness (in.)
0.0145
> 0.0140 0.0140  
> 0.0350  
> 0.0400  
> 0.0157  


Approved Contents 2.0 Table 2.1-2 (page 4 of 5)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-40 Table 2.1-2 (page 4 of 5)
PWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
PWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
Fuel Assembly Array/ Class             17x17A         17x17B     17x17C Clad Material                           ZR               ZR         ZR Design Initial U (kg/assy.)(Note
Fuel Assembly Array/ Class 17x17A 17x17B 17x17C Clad Material ZR ZR ZR Design Initial U (kg/assy.)(Note
                                                < 433           < 474       < 480 3)
: 3)
                                              < 4.0 (24)      < 4.0 (24)  < 4.0 (24)
< 433  
Initial Enrichment (MPC-24, 24E, and 24EF without soluble boron credit)(wt % 235U) (Note
< 474  
                                                < 4.4            < 4.4     < 4.4 7)
< 480 Initial Enrichment (MPC-24, 24E, and 24EF without soluble boron credit)(wt % 235U) (Note
(24E/24EF)     (24E/24EF) (24E/24EF)
: 7)
Initial Enrichment (MPC-24, 24E, 24EF, 32, or 32F with
< 4.0 (24)
                                                < 5.0            < 5.0      < 5.0 soluble boron credit - see Note
< 4.4 (24E/24EF)
: 5) (wt % 235U)
< 4.0 (24)  
No. of Fuel Rod Locations 264              264        264 (Note 11)
< 4.4 (24E/24EF)  
Fuel Rod Clad O.D. (in.)               > 0.360         > 0.372     > 0.377 Fuel Rod Clad I.D. (in.)             < 0.3150         < 0.3310   < 0.3330 Fuel Pellet Dia. (in.) (Note 8)       < 0.3088         < 0.3232   < 0.3252 Fuel Rod Pitch (in.)                   < 0.496         < 0.496     < 0.502 Active Fuel Length (in.)               < 150           < 150       < 150 No. of Guide and/or Instrument 25             25         25 Tubes Guide/Instrument Tube
< 4.0 (24)  
                                              > 0.016         > 0.014     > 0.020 Thickness (in.)
< 4.4 (24E/24EF)
Certificate of Compliance No. 1014                                      Amendment No. 12 Appendix B                                        2-40
Initial Enrichment (MPC-24, 24E, 24EF, 32, or 32F with soluble boron credit - see Note
: 5) (wt % 235U)  
< 5.0
< 5.0
< 5.0 No. of Fuel Rod Locations (Note 11) 264 264 264 Fuel Rod Clad O.D. (in.)  
> 0.360  
> 0.372  
> 0.377 Fuel Rod Clad I.D. (in.)  
< 0.3150  
< 0.3310  
< 0.3330 Fuel Pellet Dia. (in.) (Note 8)  
< 0.3088  
< 0.3232  
< 0.3252 Fuel Rod Pitch (in.)  
< 0.496  
< 0.496  
< 0.502 Active Fuel Length (in.)  
< 150  
< 150  
< 150 No. of Guide and/or Instrument Tubes 25 25 25 Guide/Instrument Tube Thickness (in.)
> 0.016  
> 0.014  
> 0.020  


Approved Contents 2.0 Table 2.1-2 (page 5 of 5)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-41 Table 2.1-2 (page 5 of 5)
PWR FUEL ASSEMBLY CHARACTERISTICS Notes:
PWR FUEL ASSEMBLY CHARACTERISTICS Notes:
: 1. All dimensions are design nominal values. Maximum and minimum dimensions are specified to bound variations in design nominal values among fuel assemblies within a given array/class.
: 1. All dimensions are design nominal values. Maximum and minimum dimensions are specified to bound variations in design nominal values among fuel assemblies within a given array/class.
Line 527: Line 716:
: 9. This fuel assembly array/class can only be loaded in MPC-32.
: 9. This fuel assembly array/class can only be loaded in MPC-32.
: 10. One Instrument Tube and eight Guide Bars (Solid ZR).
: 10. One Instrument Tube and eight Guide Bars (Solid ZR).
: 11. Any number of fuel rods in an assembly can be replaced by irradiated or unirradiated Steel or Zirconia rods. If the rods are irradiated, the site specific dose and dose rate analyses performed under 10 CFR 72.212 should include considerations for the presence of such rods.
: 11. Any number of fuel rods in an assembly can be replaced by irradiated or unirradiated Steel or Zirconia rods. If the rods are irradiated, the site specific dose and dose rate analyses performed under 10 CFR 72.212 should include considerations for the presence of such rods.  
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-41


Approved Contents 2.0 Table 2.1-3 (page 1 of 6)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-42 Table 2.1-3 (page 1 of 6)
BWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
BWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
Fuel Assembly 6x6A       6x6B         6x6C     7x7A     7x7B     8x8A Array/Class Clad Material             ZR         ZR           ZR       ZR       ZR       ZR Design Initial U
Fuel Assembly Array/Class 6x6A 6x6B 6x6C 7x7A 7x7B 8x8A Clad Material ZR ZR ZR ZR ZR ZR Design Initial U (kg/assy.) (Note 3)
                          < 110     < 110       < 110   < 100   < 198     < 120 (kg/assy.) (Note 3)
< 110  
Maximum PLANAR-                          < 2.7 for AVERAGE                          the UO2 INITIAL                            rods.
< 110  
ENRICHMENT              < 2.7  See Note         < 2.7   < 2.7   < 4.2     < 2.7 (MPC-68, 68F,                      4 for and 68FF)                          MOX (wt.% 235U)                          rods (Note 14)
< 110  
Maximum PLANAR-AVERAGE INITIAL Note 18    Note 18      Note 18  Note 18    4.8  Note 18 ENRICHMENT (MPC-68M)
< 100  
< 198  
< 120 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68, 68F, and 68FF)
(wt.% 235U)
(Note 14)  
< 2.7
< 2.7 for the UO2 rods.
See Note 4 for MOX rods
< 2.7  
< 2.7  
< 4.2  
< 2.7 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68M)
(wt.% 235U)
(wt.% 235U)
(Note 16, 19)
(Note 16, 19)
Initial Maximum Rod Enrichment           < 4.0     < 4.0         < 4.0   < 5.5   < 5.0     < 4.0 (wt.% 235U)
Note 18 Note 18 Note 18 Note 18 4.8 Note 18 Initial Maximum Rod Enrichment (wt.% 235U)
No. of Fuel Rod                   35 or 36 Locations (Note 20)   35 or 36   (up to 9       36       49       49     63 or 64 MOX rods)
< 4.0  
Fuel Rod Clad O.D.
< 4.0  
                        > 0.5550   > 0.5625     > 0.5630 > 0.4860 > 0.5630 > 0.4120 (in.)
< 4.0  
Fuel Rod Clad I.D.
< 5.5  
                        < 0.5105   < 0.4945     < 0.4990 < 0.4204 < 0.4990 < 0.3620 (in.)
< 5.0  
Fuel Pellet Dia. (in.) < 0.4980   < 0.4820     < 0.4880 < 0.4110 < 0.4910 < 0.3580 Fuel Rod Pitch (in.)   < 0.710   < 0.710     < 0.740 < 0.631 < 0.738   < 0.523 Active Fuel Length
< 4.0 No. of Fuel Rod Locations (Note 20) 35 or 36 35 or 36 (up to 9 MOX rods) 36 49 49 63 or 64 Fuel Rod Clad O.D.
                          < 120     < 120       < 77.5   < 80   < 150     < 120 (in.)
(in.)
No. of Water Rods 1 or 0     1 or 0         0       0       0       1 or 0 (Note 11)
> 0.5550  
Water Rod
> 0.5625  
                            >0         >0           N/A     N/A     N/A       >0 Thickness (in.)
> 0.5630  
Channel Thickness
> 0.4860  
                          < 0.060   < 0.060     < 0.060 < 0.060 < 0.120   < 0.100 (in.)
> 0.5630  
Certificate of Compliance No. 1014                                    Amendment No. 12 Appendix B                                    2-42
> 0.4120 Fuel Rod Clad I.D.
(in.)
< 0.5105  
< 0.4945  
< 0.4990  
< 0.4204  
< 0.4990  
< 0.3620 Fuel Pellet Dia. (in.)  
< 0.4980  
< 0.4820  
< 0.4880  
< 0.4110  
< 0.4910  
< 0.3580 Fuel Rod Pitch (in.)  
< 0.710  
< 0.710  
< 0.740  
< 0.631  
< 0.738  
< 0.523 Active Fuel Length (in.)
< 120  
< 120  
< 77.5  
< 80  
< 150  
< 120 No. of Water Rods (Note 11) 1 or 0 1 or 0 0
0 0
1 or 0 Water Rod Thickness (in.)  
> 0  
> 0 N/A N/A N/A  
> 0 Channel Thickness (in.)  
< 0.060  
< 0.060  
< 0.060  
< 0.060  
< 0.120  
< 0.100  


Approved Contents 2.0 Table 2.1-3 (2 of 6)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-43 Table 2.1-3 (2 of 6)
BWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
BWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
Fuel Assembly 8x8B     8x8C         8x8D     8x8E     8x8F       9x9A Array/Class Clad Material             ZR       ZR           ZR       ZR       ZR         ZR Design Initial U
Fuel Assembly Array/Class 8x8B 8x8C 8x8D 8x8E 8x8F 9x9A Clad Material ZR ZR ZR ZR ZR ZR Design Initial U (kg/assy.) (Note 3)
                          < 192     < 190         < 190   < 190     < 191     < 180 (kg/assy.) (Note 3)
< 192  
Maximum PLANAR-AVERAGE INITIAL ENRICHMENT               < 4.2    < 4.2        < 4.2    < 4.2    < 4.0      < 4.2 (MPC-68, 68F, and 68FF)
< 190  
< 190  
< 190  
< 191  
< 180 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68, 68F, and 68FF)
(wt.% 235U)
(wt.% 235U)
(Note 14)
(Note 14)  
Maximum PLANAR-AVERAGE INITIAL                                                            4.5 4.8      4.8        4.8    4.8                4.8 ENRICHMENT                                                     (Note 15)
< 4.2
(MPC-68M)
< 4.2
< 4.2
< 4.2
< 4.0
< 4.2 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68M)
(wt.% 235U)
(wt.% 235U)
(Note 16, 19)
(Note 16, 19) 4.8 4.8 4.8 4.8 4.5 (Note 15) 4.8 Initial Maximum Rod Enrichment (wt.% 235U)
Initial Maximum Rod Enrichment           < 5.0     < 5.0       < 5.0   < 5.0   < 5.0     < 5.0 (wt.% 235U)
< 5.0  
No. of Fuel Rod                                                             74/66 Locations (Note 20)   63 or 64     62       60 or 61   59       64 (Note 5)
< 5.0  
< 5.0  
< 5.0  
< 5.0  
< 5.0 No. of Fuel Rod Locations (Note 20) 63 or 64 62 60 or 61 59 64 74/66 (Note 5)
Fuel Rod Clad O.D.
Fuel Rod Clad O.D.
                        > 0.4840 > 0.4830     > 0.4830 > 0.4930 > 0.4576   > 0.4400 (in.)
(in.)
Fuel Rod Clad I.D.
> 0.4840  
                        < 0.4295 < 0.4250     < 0.4230 < 0.4250 < 0.3996   < 0.3840 (in.)
> 0.4830  
Fuel Pellet Dia. (in.) < 0.4195 < 0.4160     < 0.4140 < 0.4160 < 0.3913   < 0.3760 Fuel Rod Pitch (in.)   < 0.642   < 0.641       < 0.640 < 0.640   < 0.609   < 0.566 Design Active Fuel
> 0.4830  
                          < 150     < 150         < 150   < 150     < 150     < 150 Length (in.)
> 0.4930  
No. of Water Rods                               1-4                N/A (Note 11)               1 or 0       2                    5                  2 (Note 7)         (Note 12)
> 0.4576  
Water Rod
> 0.4400 Fuel Rod Clad I.D.
                        > 0.034   > 0.00       > 0.00 > 0.034 > 0.0315   > 0.00 Thickness (in.)
(in.)
Channel Thickness
< 0.4295  
                        < 0.120   < 0.120       < 0.120 < 0.100   < 0.055   < 0.120 (in.)
< 0.4250  
Certificate of Compliance No. 1014                                Amendment No. 12 Appendix B                                  2-43
< 0.4230  
< 0.4250  
< 0.3996  
< 0.3840 Fuel Pellet Dia. (in.)  
< 0.4195  
< 0.4160  
< 0.4140  
< 0.4160  
< 0.3913  
< 0.3760 Fuel Rod Pitch (in.)  
< 0.642  
< 0.641  
< 0.640  
< 0.640  
< 0.609  
< 0.566 Design Active Fuel Length (in.)
< 150  
< 150  
< 150  
< 150  
< 150  
< 150 No. of Water Rods (Note 11) 1 or 0 2
1 - 4 (Note 7) 5 N/A (Note 12) 2 Water Rod Thickness (in.)
> 0.034  
> 0.00  
> 0.00  
> 0.034  
> 0.0315  
> 0.00 Channel Thickness (in.)  
< 0.120  
< 0.120  
< 0.120  
< 0.100  
< 0.055  
< 0.120  


Approved Contents 2.0 Table 2.1-3 (page 3 of 6)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-44 Table 2.1-3 (page 3 of 6)
BWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
BWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
Fuel Assembly             9x9B       9x9C         9x9D       9x9E     9x9F      9x9G Array/Class                                                (Note 13) (Note 13)
Fuel Assembly Array/Class 9x9B 9x9C 9x9D 9x9E (Note 13) 9x9F (Note 13) 9x9G Clad Material ZR ZR ZR ZR ZR ZR Design Initial U (kg/assy.)(Note 3)
Clad Material             ZR         ZR           ZR         ZR       ZR         ZR Design Initial U         < 180       < 182         < 182     < 183     < 183     < 164 (kg/assy.)(Note 3)
< 180  
Maximum PLANAR-AVERAGE INITIAL ENRICHMENT               < 4.2      < 4.2        < 4.2      < 4.0    < 4.0    < 4.2 (MPC-68, 68F, and 68FF)
< 182  
< 182  
< 183  
< 183  
< 164 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68, 68F, and 68FF)
(wt.% 235U)
(wt.% 235U)
(Note 14)
(Note 14)  
Maximum PLANAR-AVERAGE INITIAL                                                        4.5      4.5 4.8        4.8        4.8                            4.8 ENRICHMENT                                                 (Note 15) (Note 15)
< 4.2
(MPC-68M)
< 4.2
< 4.2
< 4.0
< 4.0
< 4.2 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68M)
(wt.% 235U)
(wt.% 235U)
(Note 16, 19)
(Note 16, 19) 4.8 4.8 4.8 4.5 (Note 15) 4.5 (Note 15) 4.8 Initial Maximum Rod Enrichment (wt.% 235U)
Initial Maximum           < 5.0       < 5.0       < 5.0       < 5.0     < 5.0     < 5.0 Rod Enrichment (wt.% 235U)
< 5.0  
No. of Fuel Rod           72         80           79         76       76         72 Locations (Note 20)
< 5.0  
Fuel Rod Clad O.D.     > 0.4330     > 0.4230     > 0.4240   > 0.4170 > 0.4430 > 0.4240 (in.)
< 5.0  
Fuel Rod Clad I.D.     < 0.3810     < 0.3640     < 0.3640   < 0.3640 < 0.3860 < 0.3640 (in.)
< 5.0  
Fuel Pellet Dia. (in.) < 0.3740     < 0.3565     < 0.3565   < 0.3530 < 0.3745 < 0.3565 Fuel Rod Pitch (in.)   < 0.572     < 0.572       < 0.572   < 0.572   < 0.572   < 0.572 Design Active Fuel       < 150       < 150         < 150     < 150     < 150     < 150 Length (in.)
< 5.0  
No. of Water Rods     1 (Note 6)       1             2         5         5     1 (Note 6)
< 5.0 No. of Fuel Rod Locations (Note 20) 72 80 79 76 76 72 Fuel Rod Clad O.D.
(Note 11)
(in.)
Water Rod                > 0.00     > 0.020     > 0.0300   > 0.0120 > 0.0120 > 0.0320 Thickness (in.)
> 0.4330  
Channel Thickness      < 0.120     < 0.100       < 0.100   < 0.120   < 0.120   < 0.120 (in.)
> 0.4230  
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-44
> 0.4240  
> 0.4170  
> 0.4430  
> 0.4240 Fuel Rod Clad I.D.
(in.)
< 0.3810  
< 0.3640  
< 0.3640  
< 0.3640  
< 0.3860  
< 0.3640 Fuel Pellet Dia. (in.)  
< 0.3740  
< 0.3565  
< 0.3565  
< 0.3530  
< 0.3745  
< 0.3565 Fuel Rod Pitch (in.)  
< 0.572  
< 0.572  
< 0.572  
< 0.572  
< 0.572  
< 0.572 Design Active Fuel Length (in.)
< 150  
< 150  
< 150  
< 150  
< 150  
< 150 No. of Water Rods (Note 11) 1 (Note 6) 1 2
5 5
1 (Note 6)
Water Rod Thickness (in.)  
> 0.00  
> 0.020  
> 0.0300  
> 0.0120  
> 0.0120  
> 0.0320 Channel Thickness (in.)  
< 0.120  
< 0.100  
< 0.100  
< 0.120  
< 0.120  
< 0.120  


Approved Contents 2.0 Table 2.1-3 (page 4 of 6)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-45 Table 2.1-3 (page 4 of 6)
BWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
BWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)
Fuel Assembly 10x10A   10x10B   10x10C   10x10D 10x10E   10x10F   10x10G Array/Class Clad Material               ZR       ZR       ZR     SS     SS       ZR         ZR Design Initial U (kg/assy.)               < 188   < 188     < 179   < 125   < 125     192     188 (Note 3)
Fuel Assembly Array/Class 10x10A 10x10B 10x10C 10x10D 10x10E 10x10F 10x10G Clad Material ZR ZR ZR SS SS ZR ZR Design Initial U (kg/assy.)
Maximum PLANAR-AVERAGE INITIAL ENRICHMENT(MPC-           < 4.2   < 4.2     < 4.2   < 4.0   < 4.0   Note 17   Note 17 68, 68F, and 68FF)
(Note 3)
(wt.% 235U) (Note 14)
< 188  
Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-                                                       4.7      4.75 4.8    4.8      4.8  Note 18 Note 18 68M)                                                                (Note 15) (Note 15)
< 188  
< 179  
< 125  
< 125 192 188 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT(MPC-68, 68F, and 68FF)
(wt.% 235U) (Note 14)
< 4.2  
< 4.2  
< 4.2  
< 4.0  
< 4.0 Note 17 Note 17 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68M)
(wt.% 235U)
(wt.% 235U)
(Note 16, 19)
(Note 16, 19) 4.8 4.8 4.8 Note 18 Note 18 4.7 (Note 15) 4.75 (Note 15)
Initial Maximum Rod
Initial Maximum Rod Enrichment (wt.% 235U)
                            < 5.0   < 5.0     < 5.0   < 5.0   < 5.0   < 5.0     < 5.0 Enrichment (wt.% 235U)
< 5.0  
No. of Fuel Rod           92/78    91/83                              92/78    96/84 96      100    96 Locations (Note 20)     (Note 8) (Note 9)                           (Note 8)
< 5.0  
Fuel Rod Clad O.D.           >        >                >      >
< 5.0  
                                            > 0.3780                  0.4035    0.387 (in.)                     0.4040   0.3957           0.3960 0.3940 Fuel Rod Clad I.D. (in.)     <        <                <      <
< 5.0  
                                            < 0.3294                  0.3570    0.340 0.3520  0.3480            0.3560  0.3500 Fuel Pellet Dia. (in.)       <        <                <      <
< 5.0  
                                            < 0.3224                  0.3500    0.334 0.3455  0.3420            0.3500 0.3430 Fuel Rod Pitch (in.)     < 0.510 < 0.510   < 0.488 < 0.565 < 0.557   0.510   0.512 Design Active Fuel
< 5.0  
                          < 150   < 150     < 150   < 83   < 83     150     150 Length (in.)
< 5.0 No. of Fuel Rod Locations (Note 20) 92/78 (Note 8) 91/83 (Note 9) 96 100 96 92/78 (Note 8) 96/84 Fuel Rod Clad O.D.
No. of Water Rods                     1        5                                  5 2                          0      4        2 (Note 11)                         (Note 6) (Note 10)                           (Note 10)
(in.)
Water Rod Thickness
0.4040 0.3957  
                          > 0.030 > 0.00   > 0.031   N/A   > 0.022   0.030   0.031 (in.)
> 0.3780 0.3960 0.3940 0.4035 0.387 Fuel Rod Clad I.D. (in.)
Channel Thickness
0.3520 0.3480
                          < 0.120 < 0.120   < 0.055 < 0.080 < 0.080   0.120   0.060 (in.)
< 0.3294 0.3560 0.3500 0.3570 0.340 Fuel Pellet Dia. (in.)
Certificate of Compliance No. 1014                                    Amendment No. 12 Appendix B                                    2-45
0.3455 0.3420
< 0.3224 0.3500 0.3430 0.3500 0.334 Fuel Rod Pitch (in.)  
< 0.510  
< 0.510  
< 0.488  
< 0.565  
< 0.557 0.510 0.512 Design Active Fuel Length (in.)
< 150  
< 150  
< 150  
< 83  
< 83 150 150 No. of Water Rods (Note 11) 2 1
(Note 6) 5 (Note 10) 0 4
2 5
(Note 10)
Water Rod Thickness (in.)
> 0.030  
> 0.00  
> 0.031 N/A  
> 0.022 0.030 0.031 Channel Thickness (in.)  
< 0.120  
< 0.120  
< 0.055  
< 0.080  
< 0.080 0.120 0.060  


Approved Contents 2.0 Table 2.1-3 (page 5 of 6)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-46 Table 2.1-3 (page 5 of 6)
BWR FUEL ASSEMBLY CHARACTERISTICS Notes:
BWR FUEL ASSEMBLY CHARACTERISTICS Notes:
: 1. All dimensions are design nominal values. Maximum and minimum dimensions are specified to bound variations in design nominal values among fuel assemblies within a given array/class.
: 1.
: 2. Deleted.
All dimensions are design nominal values. Maximum and minimum dimensions are specified to bound variations in design nominal values among fuel assemblies within a given array/class.
: 3. Design initial uranium weight is the nominal uranium weight specified for each assembly by the fuel manufacturer or reactor user. For each BWR fuel assembly, the total uranium weight limit specified in this table may be increased up to 1.5 percent for comparison with users fuel records.
: 2.
: 4. 0.635 wt. % 235U and 1.578 wt. % total fissile plutonium (239Pu and 241Pu),
Deleted.
: 3.
Design initial uranium weight is the nominal uranium weight specified for each assembly by the fuel manufacturer or reactor user. For each BWR fuel assembly, the total uranium weight limit specified in this table may be increased up to 1.5 percent for comparison with users fuel records.
: 4.
0.635 wt. % 235U and 1.578 wt. % total fissile plutonium (239Pu and 241Pu),
(wt. % of total fuel weight, i.e., UO2 plus PuO2).
(wt. % of total fuel weight, i.e., UO2 plus PuO2).
: 5. This assembly class contains 74 total rods; 66 full length rods and 8 partial length rods.
: 5.
: 6. Square, replacing nine fuel rods.
This assembly class contains 74 total rods; 66 full length rods and 8 partial length rods.
: 7. Variable.
: 6.
: 8. This assembly contains 92 total fuel rods; 78 full length rods and 14 partial length rods.
Square, replacing nine fuel rods.
: 9. This assembly class contains 91 total fuel rods; 83 full length rods and 8 partial length rods.
: 7.
Variable.
: 8.
This assembly contains 92 total fuel rods; 78 full length rods and 14 partial length rods.
: 9.
This assembly class contains 91 total fuel rods; 83 full length rods and 8 partial length rods.
: 10. One diamond-shaped water rod replacing the four center fuel rods and four rectangular water rods dividing the assembly into four quadrants.
: 10. One diamond-shaped water rod replacing the four center fuel rods and four rectangular water rods dividing the assembly into four quadrants.
: 11. These rods may also be sealed at both ends and contain Zr material in lieu of water.
: 11. These rods may also be sealed at both ends and contain Zr material in lieu of water.
Line 643: Line 1,017:
: 14. For MPC-68, 68F, and 68FF loaded with both INTACT FUEL ASSEMBLIES and DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, the maximum PLANAR AVERAGE INITIAL ENRICHMENT for the INTACT FUEL ASSEMBLIES is limited to 3.7 wt.% 235U, as applicable.
: 14. For MPC-68, 68F, and 68FF loaded with both INTACT FUEL ASSEMBLIES and DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, the maximum PLANAR AVERAGE INITIAL ENRICHMENT for the INTACT FUEL ASSEMBLIES is limited to 3.7 wt.% 235U, as applicable.
: 15. Fuel assemblies classified as damaged fuel assemblies are limited to 4.6 wt.%
: 15. Fuel assemblies classified as damaged fuel assemblies are limited to 4.6 wt.%
235U for the 10x10F and 10x10G arrays/classes and 4.0 wt.% 235U for the 8x8F, 9x9E and 9x9F arrays/classes.
235U for the 10x10F and 10x10G arrays/classes and 4.0 wt.% 235U for the 8x8F, 9x9E and 9x9F arrays/classes.  
Certificate of Compliance No. 1014                                      Amendment No. 12 Appendix B                                    2-46


Approved Contents 2.0 Table 2.1-3 (page 6 of 6)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-47 Table 2.1-3 (page 6 of 6)
BWR FUEL ASSEMBLY CHARACTERISTICS
BWR FUEL ASSEMBLY CHARACTERISTICS
: 16. For MPC-68M loaded with both UNDAMAGED FUEL ASSEMBLIES and DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, the maximum PLANAR AVERAGE INITIAL ENRICHMENT for the UNDAMAGED FUEL ASSEMBLIES is limited to the enrichment limit of the damaged assembly.
: 16. For MPC-68M loaded with both UNDAMAGED FUEL ASSEMBLIES and DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, the maximum PLANAR AVERAGE INITIAL ENRICHMENT for the UNDAMAGED FUEL ASSEMBLIES is limited to the enrichment limit of the damaged assembly.
Line 652: Line 1,025:
: 18. This fuel assembly array/class is not allowable contents in MPC-68M.
: 18. This fuel assembly array/class is not allowable contents in MPC-68M.
: 19. In accordance with the definition of UNDAMAGED FUEL ASSEMBLY, certain assemblies may be limited to up to 3.3 wt.% U-235. When loading these fuel assemblies, all other undamaged fuel assemblies in the MPC are limited to enrichments as specified in this table.
: 19. In accordance with the definition of UNDAMAGED FUEL ASSEMBLY, certain assemblies may be limited to up to 3.3 wt.% U-235. When loading these fuel assemblies, all other undamaged fuel assemblies in the MPC are limited to enrichments as specified in this table.
: 20. Any number of fuel rods in an assembly can be replaced by irradiated or unirradiated Steel or Zirconia rods. If the rods are irradiated, the site specific dose and dose rate analyses performed under 10 CFR 72.212 should include considerations for the presence of such rods.
: 20. Any number of fuel rods in an assembly can be replaced by irradiated or unirradiated Steel or Zirconia rods. If the rods are irradiated, the site specific dose and dose rate analyses performed under 10 CFR 72.212 should include considerations for the presence of such rods.  
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-47


Approved Contents 2.0
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-48
: 12. Table 2.1-8 NON-FUEL HARDWARE COOLING AND AVERAGE BURNUP (Notes 1, 2, 3, and 7)
: 12. Table 2.1-8 NON-FUEL HARDWARE COOLING AND AVERAGE BURNUP (Notes 1, 2, 3, and 7)
Post-            NSA with NFH                                NSA without            APSR irradiation                                                      NFH, GUIDE          BURNUP INSERTS Cooling Time                                                          TUBE            (MWD/MTU)
(Note 4)
(years)              BURNUP                                HARDWARE, or (MWD/MTU)                                    CONTROL COMPONENT (Note 5)
BURNUP (MWD/MTU) 3                  24,635                                NA (Note 6)            NA 4                  30,000                                      NA                NA 5                  36,748                                  630,000            45,000 6                  44,102                                      -              54,500 7                  52,900                                      -              68,000 8                  60,000                                      -              83,000 9                  79,784                                      -              111,000 10                101,826                                      -              180,000 11                141,982                                      -              630,000 12                360,000                                      -                  -
Notes: 1. Burnups for NON-FUEL HARDWARE are to be determined based on the burnup and uranium mass of the fuel assemblies in which the component was inserted during reactor operation.
Notes: 1. Burnups for NON-FUEL HARDWARE are to be determined based on the burnup and uranium mass of the fuel assemblies in which the component was inserted during reactor operation.
: 2. Linear interpolation between points is permitted, except that APSR burnups > 180,000 MWD/MTU and < 630,000 MWD/MTU must be cooled > 11 years.
: 2. Linear interpolation between points is permitted, except that APSR burnups > 180,000 MWD/MTU and < 630,000 MWD/MTU must be cooled > 11 years.
Line 668: Line 1,036:
: 6. NA means not authorized for loading at this cooling time.
: 6. NA means not authorized for loading at this cooling time.
: 7. Non-fuel hardware burnup and cooling times are not applicable to ITTRs since they are installed post irradiation.
: 7. Non-fuel hardware burnup and cooling times are not applicable to ITTRs since they are installed post irradiation.
Certificate of Compliance No. 1014                                                Amendment No. 12 Appendix B                                        2-48
Post-irradiation Cooling Time (years)
NSA with NFH INSERTS (Note 4)
BURNUP (MWD/MTU)
NSA without NFH, GUIDE TUBE HARDWARE, or CONTROL COMPONENT (Note 5)
BURNUP (MWD/MTU)
APSR BURNUP (MWD/MTU) 3 24,635 NA (Note 6)
NA 4
30,000 NA NA 5
36,748 630,000 45,000 6
44,102 54,500 7
52,900 68,000 8
60,000 83,000 9
79,784 111,000 10 101,826 180,000 11 141,982 630,000 12 360,000


Approved Contents 2.0 2.4     Decay Heat, Burnup, and Cooling Time Limits for ZR-Clad Fuel This section provides the limits on ZR-clad fuel assembly decay heat, burnup, and cooling time for storage in the HI-STORM 100 System. The method to calculate the limits and verify compliance, including examples, is provided in Chapter 12 of the HI-STORM 100 FSAR.
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-49 2.4 Decay Heat, Burnup, and Cooling Time Limits for ZR-Clad Fuel This section provides the limits on ZR-clad fuel assembly decay heat, burnup, and cooling time for storage in the HI-STORM 100 System. The method to calculate the limits and verify compliance, including examples, is provided in Chapter 12 of the HI-STORM 100 FSAR.
2.4.1 Uniform Fuel Loading Decay Heat Limits for ZR-clad fuel Table 2.4-1 provides the maximum allowable decay heat per fuel storage location for ZR-clad fuel in uniform fuel loading for each MPC model.
2.4.1 Uniform Fuel Loading Decay Heat Limits for ZR-clad fuel Table 2.4-1 provides the maximum allowable decay heat per fuel storage location for ZR-clad fuel in uniform fuel loading for each MPC model.
Table 2.4-1 Maximum Allowable Decay Heat per Fuel Storage Location (Uniform Loading, ZR-Clad)
Table 2.4-1 Maximum Allowable Decay Heat per Fuel Storage Location (Uniform Loading, ZR-Clad)
Decay Heat per Fuel Storage Location MPC Model                                      (kW)
MPC Model Decay Heat per Fuel Storage Location (kW)
Intact or Undamaged         Damaged Fuel Assemblies Fuel Assemblies               and Fuel Debris MPC-24                     < 1.416                   Not Permitted MPC-24E/24EF                     < 1.416                     < 1.114 MPC-32/32F                     < 1.062                     < 0.718 MPC-68/68FF/68M                   < 0.500                     < 0.393 Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-49
Intact or Undamaged Fuel Assemblies Damaged Fuel Assemblies and Fuel Debris MPC-24  
< 1.416 Not Permitted MPC-24E/24EF  
< 1.416  
< 1.114 MPC-32/32F  
< 1.062  
< 0.718 MPC-68/68FF/68M  
< 0.500  
< 0.393  


Approved Contents 2.0 2.4.2 Regionalized Fuel Loading Decay Heat Limits for ZR-Clad Fuel (Intact or Undamaged Fuel only)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-50 2.4.2 Regionalized Fuel Loading Decay Heat Limits for ZR-Clad Fuel (Intact or Undamaged Fuel only)
The maximum allowable decay heat per fuel storage location for intact fuel assemblies in regionalized loading is determined using the following equations:
The maximum allowable decay heat per fuel storage location for intact fuel assemblies in regionalized loading is determined using the following equations:
Q(X) = 2 x Q0 / (1 + Xy) y = 0.23 / X0.1 q2 = Q(X) / (n1 x X +n2) q1 = q2 x X Where:
Q(X) = 2 x Q0 / (1 + Xy) y = 0.23 / X0.1 q2 = Q(X) / (n1 x X +n2) q1 = q2 x X Where:
Q0 = Maximum uniform storage MPC decay heat (34 kW)
Q0 = Maximum uniform storage MPC decay heat (34 kW)
X = Inner region to outer region assembly decay heat ratio (0.5 X 3) n1 = Number of storage locations in inner region from Table 2.4-2.
X = Inner region to outer region assembly decay heat ratio (0.5 X 3) n1 = Number of storage locations in inner region from Table 2.4-2.
n2 = Number of storage locations in outer region from Table 2.4-2.
n2 = Number of storage locations in outer region from Table 2.4-2.
Allowable heat loads for Damaged Fuel and Fuel Debris in regionalized loading are shown in Table 2.4-5.
Allowable heat loads for Damaged Fuel and Fuel Debris in regionalized loading are shown in Table 2.4-5.
An optional regionalized loading pattern for MPC-68M is shown in Figure 2.4-1.
An optional regionalized loading pattern for MPC-68M is shown in Figure 2.4-1.  
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-50


Approved Contents 2.0 Table 2.4-2 Fuel Storage Regions per MPC MPC Model                 Number of Storage Locations         Number of Storage in Inner Region (Region 1)         Locations in Outer Region (Region 2)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-51 Table 2.4-2 Fuel Storage Regions per MPC MPC Model Number of Storage Locations in Inner Region (Region 1)
MPC-24 and MPC-24E/EF                           12                             12 MPC- 32/32F                               12                             20 MPC-68/68FF/68MNote1                           32                             36 Note 1: For an optional regionalized loading pattern for MPC-68M, see Figure 2.4-1.
Number of Storage Locations in Outer Region (Region 2)
Table 2.4-5 Allowable Heat Load for Damaged Fuel Assemblies and Fuel Debris under Regionalized Loading MPC Model               Maximum Per Cell Allowable Heat Load for Damaged Fuel Assemblies and Fuel Debris Note 1 MPC-24E/24EF                                   0.75*q2 MPC- 32/32F                                   0.65*q2 MPC-68/68FF/68MNote 2                               0.75*q2 Note 1: q2 is the maximum permissible heat load in Region 2 for intact fuel assemblies.
MPC-24 and MPC-24E/EF 12 12 MPC-32/32F 12 20 MPC-68/68FF/68MNote1 32 36 Note 1: For an optional regionalized loading pattern for MPC-68M, see Figure 2.4-1.
Note 2: An optional regionalized loading pattern for MPC-68M including Damaged Fuel and Fuel Debris is shown in Figure 2.4-1 Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      2-51
Table 2.4-5 Allowable Heat Load for Damaged Fuel Assemblies and Fuel Debris under Regionalized Loading MPC Model Maximum Per Cell Allowable Heat Load for Damaged Fuel Assemblies and Fuel Debris Note 1 MPC-24E/24EF 0.75*q2 MPC-32/32F 0.65*q2 MPC-68/68FF/68MNote 2 0.75*q2 Note 1: q2 is the maximum permissible heat load in Region 2 for intact fuel assemblies.
Note 2: An optional regionalized loading pattern for MPC-68M including Damaged Fuel and Fuel Debris is shown in Figure 2.4-1  


Approved Contents 2.0 2.4.3       Burnup Limits as a Function of Cooling Time for ZR-Clad Fuel The maximum allowable fuel assembly average burnup varies with the following parameters:
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-52 2.4.3 Burnup Limits as a Function of Cooling Time for ZR-Clad Fuel The maximum allowable fuel assembly average burnup varies with the following parameters:
* Minimum fuel assembly cooling time
* Minimum fuel assembly cooling time
* Maximum fuel assembly decay heat
* Maximum fuel assembly decay heat
* Minimum fuel assembly average enrichment The maximum allowable ZR-clad fuel assembly average burnup for a given MINIMUM ENRICHMENT is calculated as described below for minimum cooling times between 2 and 40 years using the maximum permissible decay heat determined in Section 2.4.1 or 2.4.2. Different fuel assembly average burnup limits may be calculated for different minimum enrichments (by individual fuel assembly) for use in choosing the fuel assemblies to be loaded into a given MPC.
* Minimum fuel assembly average enrichment The maximum allowable ZR-clad fuel assembly average burnup for a given MINIMUM ENRICHMENT is calculated as described below for minimum cooling times between 2 and 40 years using the maximum permissible decay heat determined in Section 2.4.1 or 2.4.2. Different fuel assembly average burnup limits may be calculated for different minimum enrichments (by individual fuel assembly) for use in choosing the fuel assemblies to be loaded into a given MPC.
2.4.3.1 Choose a fuel assembly minimum enrichment, E235.
2.4.3.1 Choose a fuel assembly minimum enrichment, E235.
2.4.3.2 Calculate the maximum allowable fuel assembly average burnup for a minimum cooling time between 2 and 40 years using the equation below.
2.4.3.2 Calculate the maximum allowable fuel assembly average burnup for a minimum cooling time between 2 and 40 years using the equation below.
Bu = (A x q) + (B x q2) + (C x q3) + [D x (E235)2] + (E x q x E235) + (F x q2 x E235) + G Where:
Bu = (A x q) + (B x q2) + (C x q3) + [D x (E235)2] + (E x q x E235) + (F x q2 x E235) + G Where:
Bu = Maximum allowable average burnup per fuel assembly (MWD/MTU) q=     Maximum allowable decay heat per fuel storage location determined in Section 2.4.1 or 2.4.2 (kW)
Bu = Maximum allowable average burnup per fuel assembly (MWD/MTU) q =
Maximum allowable decay heat per fuel storage location determined in Section 2.4.1 or 2.4.2 (kW)
E235 =Minimum fuel assembly average enrichment (wt. % 235U)
E235 =Minimum fuel assembly average enrichment (wt. % 235U)
(e.g., for 4.05 wt.%, use 4.05)
(e.g., for 4.05 wt.%, use 4.05)
A through G = Coefficients from Tables 2.4-3 and 2.4-4 for the applicable fuel assembly array/class and minimum cooling time 2.4.3.3 Calculated burnup limits shall be rounded down to the nearest integer.
A through G = Coefficients from Tables 2.4-3 and 2.4-4 for the applicable fuel assembly array/class and minimum cooling time 2.4.3.3 Calculated burnup limits shall be rounded down to the nearest integer.
2.4.3.4 Calculated burnup limits greater than 68,200 MWD/MTU for PWR fuel and 65,000 MWD/MTU for BWR must be reduced to be equal to these values.
2.4.3.4 Calculated burnup limits greater than 68,200 MWD/MTU for PWR fuel and 65,000 MWD/MTU for BWR must be reduced to be equal to these values.
2.4.3.5 Linear interpolation of calculated burnups between cooling times for a given fuel assembly maximum decay heat and minimum enrichment is permitted. For example, the allowable burnup for a cooling time of 4.5 years may be interpolated between those burnups calculated for 4 year and 5 years.
2.4.3.5 Linear interpolation of calculated burnups between cooling times for a given fuel assembly maximum decay heat and minimum enrichment is permitted. For example, the allowable burnup for a cooling time of 4.5 years may be interpolated between those burnups calculated for 4 year and 5 years.  
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-52


Approved Contents 2.0 2.4.3.6   Each ZR-clad fuel assembly to be stored must have a MINIMUM ENRICHMENT greater than or equal to the value used in Step 2.4.3.2.
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-53 2.4.3.6 Each ZR-clad fuel assembly to be stored must have a MINIMUM ENRICHMENT greater than or equal to the value used in Step 2.4.3.2.
2.4.4 When complying with the maximum fuel storage location decay heat limits, users must account for the decay heat from both the fuel assembly and any NON-FUEL HARDWARE, as applicable for the particular fuel storage location, to ensure the decay heat emitted by all contents in a storage location does not exceed the limit.
2.4.4 When complying with the maximum fuel storage location decay heat limits, users must account for the decay heat from both the fuel assembly and any NON-FUEL HARDWARE, as applicable for the particular fuel storage location, to ensure the decay heat emitted by all contents in a storage location does not exceed the limit.  
Certificate of Compliance No. 1014                                      Amendment No. 12 Appendix B                                  2-53


Approved Contents 2.0 Table 2.4-3 (Page 1 of 8)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-54 Table 2.4-3 (Page 1 of 8)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling                                     Array/Class 14x14A Time (years)          A         B           C           D           E       F         G 2.0         8716.89   1454.67     -91.96       -168.45     2047.50 -209.91   -738.51 2.25       10917.50   1441.49   -112.76       -162.14     2274.96 -266.46   -788.45 2.5       13452.90   1258.44   -119.69       -154.08     2491.83 -329.35   -760.18 2.75       16326.90     847.56   -100.72       -146.46     2680.07 -390.55   -727.50 3.0       19310.30     276.56     -59.30       -139.52     2851.81 -452.00   -614.85 4.0       33007.90   -4711.82   663.64       -117.16     3291.32 -622.31   -338.63 5.0       46306.70 -12448.80   2292.51       -113.20     3504.56 -662.41   -73.12 6.0       57461.80 -20693.50   4405.17       -121.14     3633.52 -614.82     1.66 7.0       66450.10 -28314.10   6635.00       -129.61     3706.00 -510.84   -113.74 8.0       73652.70 -34919.90   8759.36       -136.91     3752.43 -391.36   -311.56 9.0       79378.80 -40316.60   10606.30       -141.55     3784.66 -280.29   -485.97 10.0       84125.10 -44860.80   12239.70       -143.00     3777.62 -152.58   -635.70 11.0       88066.60 -48540.60   13594.30       -142.74     3758.54 -33.78   -726.86 12.0       91416.80 -51619.90   14789.00       -141.31     3742.31 64.80   -833.14 13.0       94657.90 -54579.30   15916.70       -137.14     3652.04 215.05   -967.41 14.0       97332.40 -56854.80   16823.50       -133.83     3610.21 315.79   -959.48 15.0       99866.10 -58816.70   17560.80       -128.68     3529.41 430.14   -991.32 16.0       102093.00 -60412.40   18171.30       -124.64     3469.67 535.07   -1078.73 17.0       104419.00 -62150.90   18846.80       -118.62     3363.97 674.13   -1092.27 18.0       106439.00 -63357.20   19259.50       -114.31     3300.43 769.38   -1137.26 19.0       108613.00 -64655.80   19660.70       -107.71     3182.61 904.63   -1084.05 20.0       110475.00 -65506.20   19883.50       -103.32     3125.81 988.08   -1062.86 22.0       114223.00 -66854.40   19969.00       -91.34     2899.19 1260.81 -1076.58 24.0       117822.00 -67556.70   19641.80       -79.56     2684.32 1499.23 -1011.23 26.0       121396.00 -67752.70   18783.80       -68.61     2465.91 1753.65   -940.82 28.0       125040.00 -67445.30   17353.90       -55.51     2184.99 2059.27   -883.36 30.0       128075.00 -65562.60   14994.70       -45.58     2003.10 2244.12   -819.25 35.0       136419.00 -58633.40   6027.48       -15.81     1354.94 2757.84   -687.83 40.0       144776.00 -48670.50   -4898.54         5.02       1019.97 2652.57   -507.64 Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-54
Cooling Time (years)
Array/Class 14x14A A
B C
D E
F G
2.0 8716.89 1454.67  
-91.96  
-168.45 2047.50  
-209.91  
-738.51 2.25 10917.50 1441.49  
-112.76  
-162.14 2274.96  
-266.46  
-788.45 2.5 13452.90 1258.44  
-119.69  
-154.08 2491.83  
-329.35  
-760.18 2.75 16326.90 847.56  
-100.72  
-146.46 2680.07  
-390.55  
-727.50 3.0 19310.30 276.56  
-59.30  
-139.52 2851.81  
-452.00  
-614.85 4.0 33007.90  
-4711.82 663.64  
-117.16 3291.32  
-622.31  
-338.63 5.0 46306.70  
-12448.80 2292.51  
-113.20 3504.56  
-662.41  
-73.12 6.0 57461.80  
-20693.50 4405.17  
-121.14 3633.52  
-614.82 1.66 7.0 66450.10  
-28314.10 6635.00  
-129.61 3706.00  
-510.84  
-113.74 8.0 73652.70  
-34919.90 8759.36  
-136.91 3752.43  
-391.36  
-311.56 9.0 79378.80  
-40316.60 10606.30  
-141.55 3784.66  
-280.29  
-485.97 10.0 84125.10  
-44860.80 12239.70  
-143.00 3777.62  
-152.58  
-635.70 11.0 88066.60  
-48540.60 13594.30  
-142.74 3758.54  
-33.78  
-726.86 12.0 91416.80  
-51619.90 14789.00  
-141.31 3742.31 64.80  
-833.14 13.0 94657.90  
-54579.30 15916.70  
-137.14 3652.04 215.05  
-967.41 14.0 97332.40  
-56854.80 16823.50  
-133.83 3610.21 315.79  
-959.48 15.0 99866.10  
-58816.70 17560.80  
-128.68 3529.41 430.14  
-991.32 16.0 102093.00  
-60412.40 18171.30  
-124.64 3469.67 535.07  
-1078.73 17.0 104419.00  
-62150.90 18846.80  
-118.62 3363.97 674.13  
-1092.27 18.0 106439.00  
-63357.20 19259.50  
-114.31 3300.43 769.38  
-1137.26 19.0 108613.00  
-64655.80 19660.70  
-107.71 3182.61 904.63  
-1084.05 20.0 110475.00  
-65506.20 19883.50  
-103.32 3125.81 988.08  
-1062.86 22.0 114223.00  
-66854.40 19969.00  
-91.34 2899.19 1260.81  
-1076.58 24.0 117822.00  
-67556.70 19641.80  
-79.56 2684.32 1499.23  
-1011.23 26.0 121396.00  
-67752.70 18783.80  
-68.61 2465.91 1753.65  
-940.82 28.0 125040.00  
-67445.30 17353.90  
-55.51 2184.99 2059.27  
-883.36 30.0 128075.00  
-65562.60 14994.70  
-45.58 2003.10 2244.12  
-819.25 35.0 136419.00  
-58633.40 6027.48  
-15.81 1354.94 2757.84  
-687.83 40.0 144776.00  
-48670.50  
-4898.54 5.02 1019.97 2652.57  
-507.64  


Approved Contents 2.0 Table 2.4-3 (Page 2 of 8)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-55 Table 2.4-3 (Page 2 of 8)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling                                     Array/Class 14x14B Time (years)          A         B           C             D           E       F       G 2.0       7962.04   1332.84     -83.96       -165.28     1836.65 -176.15 -859.65 2.25       10055.50   1296.32   -100.51       -156.80     2012.11 -217.67 -907.11 2.5       12332.50   1153.20   -110.56       -149.42     2185.46 -264.52 -845.06 2.75       15072.80   715.71     -82.42       -140.68     2336.22 -310.64 -833.26 3.0       18034.30     64.77     -24.88       -130.87     2450.80 -348.00 -857.34 4.0       30007.50   -4046.37     538.96       -110.22     2792.92 -469.98 -371.81 5.0       41033.00   -9824.17   1644.13       -108.10     2979.87 -509.22   122.91 6.0       50398.10 -16082.00   3115.79       -113.75     3084.72 -485.25   117.44 7.0       57782.60 -21657.00   4602.39       -121.19     3161.16 -433.49 -112.57 8.0       63670.20 -26431.00   6006.16       -127.70     3227.81 -382.20   -74.84 9.0       68390.50 -30359.70   7246.09       -131.82     3277.23 -336.08 -200.60 10.0       72284.50 -33630.50   8335.68       -132.71     3293.15 -279.98 -291.73 11.0       75584.30 -36387.10   9298.07       -132.38     3295.07 -227.50 -340.65 12.0       78425.20 -38681.30   10125.90       -130.36     3283.13 -176.12 -462.22 13.0       80928.60 -40624.70   10848.10       -127.28     3259.89 -127.73 -563.09 14.0       83136.90 -42279.70   11500.20       -124.50     3249.69 -97.40 -565.79 15.0       85398.00 -44023.70   12192.30       -119.64     3186.24 -30.11 -665.54 16.0       87257.50 -45137.70   12617.40       -113.94     3127.01 22.40   -678.95 17.0       89196.20 -46520.30   13209.90       -110.27     3091.45 63.17   -713.69 18.0       90991.80 -47570.50   13623.80       -104.55     3008.16 136.69 -772.63 19.0       92591.90 -48339.00   13957.70       -99.63     2967.34 161.34 -697.42 20.0       94285.30 -49165.00   14265.20       -93.25     2875.59 235.94 -721.92 22.0       97593.80 -50692.00   14904.40       -82.77     2745.24 324.79 -695.61 24.0       100677.00 -51565.30   15201.30       -71.53     2596.73 409.91 -701.93 26.0       103715.00 -52185.40   15380.80       -60.88     2445.30 499.31 -581.96 28.0       106669.00 -52197.30   15136.20       -49.42     2276.34 582.57 -547.22 30.0       109832.00 -52431.30   15114.20       -38.14     2103.73 641.34 -544.99 35.0       116933.00 -49435.10   12742.20       -10.82     1691.80 667.30 -388.35 40.0       123932.00 -43775.70   9268.80         15.25     1356.03 327.73 -339.10 Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-55
Cooling Time (years)
Array/Class 14x14B A
B C
D E
F G
2.0 7962.04 1332.84  
-83.96  
-165.28 1836.65  
-176.15  
-859.65 2.25 10055.50 1296.32  
-100.51  
-156.80 2012.11  
-217.67  
-907.11 2.5 12332.50 1153.20  
-110.56  
-149.42 2185.46  
-264.52  
-845.06 2.75 15072.80 715.71  
-82.42  
-140.68 2336.22  
-310.64  
-833.26 3.0 18034.30 64.77  
-24.88  
-130.87 2450.80  
-348.00  
-857.34 4.0 30007.50  
-4046.37 538.96  
-110.22 2792.92  
-469.98  
-371.81 5.0 41033.00  
-9824.17 1644.13  
-108.10 2979.87  
-509.22 122.91 6.0 50398.10  
-16082.00 3115.79  
-113.75 3084.72  
-485.25 117.44 7.0 57782.60  
-21657.00 4602.39  
-121.19 3161.16  
-433.49  
-112.57 8.0 63670.20  
-26431.00 6006.16  
-127.70 3227.81  
-382.20  
-74.84 9.0 68390.50  
-30359.70 7246.09  
-131.82 3277.23  
-336.08  
-200.60 10.0 72284.50  
-33630.50 8335.68  
-132.71 3293.15  
-279.98  
-291.73 11.0 75584.30  
-36387.10 9298.07  
-132.38 3295.07  
-227.50  
-340.65 12.0 78425.20  
-38681.30 10125.90  
-130.36 3283.13  
-176.12  
-462.22 13.0 80928.60  
-40624.70 10848.10  
-127.28 3259.89  
-127.73  
-563.09 14.0 83136.90  
-42279.70 11500.20  
-124.50 3249.69  
-97.40  
-565.79 15.0 85398.00  
-44023.70 12192.30  
-119.64 3186.24  
-30.11  
-665.54 16.0 87257.50  
-45137.70 12617.40  
-113.94 3127.01 22.40  
-678.95 17.0 89196.20  
-46520.30 13209.90  
-110.27 3091.45 63.17  
-713.69 18.0 90991.80  
-47570.50 13623.80  
-104.55 3008.16 136.69  
-772.63 19.0 92591.90  
-48339.00 13957.70  
-99.63 2967.34 161.34  
-697.42 20.0 94285.30  
-49165.00 14265.20  
-93.25 2875.59 235.94  
-721.92 22.0 97593.80  
-50692.00 14904.40  
-82.77 2745.24 324.79  
-695.61 24.0 100677.00  
-51565.30 15201.30  
-71.53 2596.73 409.91  
-701.93 26.0 103715.00  
-52185.40 15380.80  
-60.88 2445.30 499.31  
-581.96 28.0 106669.00  
-52197.30 15136.20  
-49.42 2276.34 582.57  
-547.22 30.0 109832.00  
-52431.30 15114.20  
-38.14 2103.73 641.34  
-544.99 35.0 116933.00  
-49435.10 12742.20  
-10.82 1691.80 667.30  
-388.35 40.0 123932.00  
-43775.70 9268.80 15.25 1356.03 327.73  
-339.10  


Approved Contents 2.0 Table 2.4-3 (Page 3 of 8)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-56 Table 2.4-3 (Page 3 of 8)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling                                     Array/Class 14x14C Time (years)          A           B           C           D           E       F       G 2.0       7910.49     1566.52   -112.06     -173.92     1975.67 -202.57 -1582.61 2.25       10090.40     1516.08   -132.53     -164.22     2144.71 -245.91 -1586.24 2.5       12672.30     1230.85   -127.98     -154.40     2293.68 -288.88 -1526.05 2.75       15404.70     785.48   -103.88     -146.02     2435.58 -333.58 -1526.92 3.0       18263.20     174.52     -57.73     -138.13     2539.97 -369.83 -1372.54 4.0       30052.40   -3931.93     484.14     -116.91     2815.30 -467.36   -710.84 5.0       40995.00   -9796.91   1583.72     -113.09     2900.21 -451.56   -204.87 6.0       49804.50   -15620.10   2905.31     -119.64     2970.21 -399.85   -228.44 7.0       56671.50   -20724.30   4228.04     -129.87     3058.54 -347.83   -244.26 8.0       62114.70   -24957.40   5410.68     -135.49     3080.42 -267.82   -216.83 9.0       66532.70   -28492.00   6458.64     -138.92     3102.21 -196.64   -343.21 10.0       70257.00   -31538.30   7424.54     -139.96     3109.64 -131.37   -466.58 11.0       73240.40   -33856.10   8182.60     -139.49     3113.36 -77.52   -528.62 12.0       75830.10   -35829.20   8857.54     -137.30     3097.43 -23.81   -597.83 13.0       78304.00   -37697.30   9499.38     -132.64     3034.49   60.52   -690.28 14.0       80401.00   -39162.40   10022.20     -129.04     3004.11 112.39   -819.41 15.0       82413.50   -40565.20   10547.80     -125.00     2972.01 159.60   -815.35 16.0       84138.60   -41575.10   10920.50     -121.03     2935.91 206.01   -844.59 17.0       85994.20   -42654.40   11295.20     -113.82     2848.12 279.72   -924.47 18.0       87721.10   -43657.50   11664.00     -108.56     2775.07 353.35   -960.97 19.0       89122.20   -44109.80   11806.40     -103.94     2740.54 384.66   -864.21 20.0       90678.60   -44723.70   11996.00       -97.44     2648.86 459.77   -907.84 22.0       93894.70   -46071.00   12444.30       -85.57     2487.47 593.03   -912.09 24.0       96742.60   -46597.20   12482.60       -75.19     2358.14 688.79   -833.76 26.0       99697.50   -47055.90   12472.30       -63.23     2185.39 810.10   -803.84 28.0       102343.00 -46639.70   11970.90       -52.13     2038.03 893.63   -704.66 30.0       105173.00 -46148.00   11326.10       -41.21     1856.73 1002.71   -620.51 35.0       111963.00 -42828.60   8640.91       -13.96     1473.64 1063.44   -455.86 40.0       118574.00 -36526.50   4330.66       12.00     1111.29 892.32   -351.40 Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-56
Cooling Time (years)
Array/Class 14x14C A
B C
D E
F G
2.0 7910.49 1566.52  
-112.06  
-173.92 1975.67  
-202.57  
-1582.61 2.25 10090.40 1516.08  
-132.53  
-164.22 2144.71  
-245.91  
-1586.24 2.5 12672.30 1230.85  
-127.98  
-154.40 2293.68  
-288.88  
-1526.05 2.75 15404.70 785.48  
-103.88  
-146.02 2435.58  
-333.58  
-1526.92 3.0 18263.20 174.52  
-57.73  
-138.13 2539.97  
-369.83  
-1372.54 4.0 30052.40  
-3931.93 484.14  
-116.91 2815.30  
-467.36  
-710.84 5.0 40995.00  
-9796.91 1583.72  
-113.09 2900.21  
-451.56  
-204.87 6.0 49804.50  
-15620.10 2905.31  
-119.64 2970.21  
-399.85  
-228.44 7.0 56671.50  
-20724.30 4228.04  
-129.87 3058.54  
-347.83  
-244.26 8.0 62114.70  
-24957.40 5410.68  
-135.49 3080.42  
-267.82  
-216.83 9.0 66532.70  
-28492.00 6458.64  
-138.92 3102.21  
-196.64  
-343.21 10.0 70257.00  
-31538.30 7424.54  
-139.96 3109.64  
-131.37  
-466.58 11.0 73240.40  
-33856.10 8182.60  
-139.49 3113.36  
-77.52  
-528.62 12.0 75830.10  
-35829.20 8857.54  
-137.30 3097.43  
-23.81  
-597.83 13.0 78304.00  
-37697.30 9499.38  
-132.64 3034.49 60.52  
-690.28 14.0 80401.00  
-39162.40 10022.20  
-129.04 3004.11 112.39  
-819.41 15.0 82413.50  
-40565.20 10547.80  
-125.00 2972.01 159.60  
-815.35 16.0 84138.60  
-41575.10 10920.50  
-121.03 2935.91 206.01  
-844.59 17.0 85994.20  
-42654.40 11295.20  
-113.82 2848.12 279.72  
-924.47 18.0 87721.10  
-43657.50 11664.00  
-108.56 2775.07 353.35  
-960.97 19.0 89122.20  
-44109.80 11806.40  
-103.94 2740.54 384.66  
-864.21 20.0 90678.60  
-44723.70 11996.00  
-97.44 2648.86 459.77  
-907.84 22.0 93894.70  
-46071.00 12444.30  
-85.57 2487.47 593.03  
-912.09 24.0 96742.60  
-46597.20 12482.60  
-75.19 2358.14 688.79  
-833.76 26.0 99697.50  
-47055.90 12472.30  
-63.23 2185.39 810.10  
-803.84 28.0 102343.00  
-46639.70 11970.90  
-52.13 2038.03 893.63  
-704.66 30.0 105173.00  
-46148.00 11326.10  
-41.21 1856.73 1002.71  
-620.51 35.0 111963.00  
-42828.60 8640.91  
-13.96 1473.64 1063.44  
-455.86 40.0 118574.00  
-36526.50 4330.66 12.00 1111.29 892.32  
-351.40  


Approved Contents 2.0 Table 2.4-3 (Page 4 of 8)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-57 Table 2.4-3 (Page 4 of 8)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling                                 Array/Class 15x15A/B/C Time (years)          A         B           C           D           E       F         G 2.0       6771.99   897.63     -45.95     -155.96     1478.91 -112.57   -571.21 2.25       8543.84   862.70     -53.16     -148.35     1638.47 -142.90   -603.00 2.5       10454.10   757.88     -56.51     -143.91     1802.08 -178.39   -613.38 2.75       12589.40   536.75     -50.58     -136.31     1939.28 -212.48   -598.75 3.0       15043.50   106.18     -18.51     -127.37     2049.65 -242.76   -584.58 4.0       25256.40   -2809.40   320.40     -108.47     2382.23 -339.78   -246.30 5.0       34995.70   -7157.77   1037.70     -104.27     2547.85 -373.57     64.26 6.0       43079.90 -11755.40   1968.81     -110.42     2669.55 -367.08   207.73 7.0       49495.50 -15880.10   2915.99     -117.70     2745.06 -335.00     79.17 8.0       54674.20 -19541.50   3863.26     -124.97     2823.26 -307.52   -139.52 9.0       58746.90 -22465.30   4666.71     -128.88     2870.36 -274.05   -284.74 10.0       62159.00 -24900.00   5358.04     -129.81     2882.28 -231.65   -307.41 11.0       64980.00 -26916.40   5974.92     -128.99     2890.02 -197.70   -320.91 12.0       67449.80 -28657.30   6533.20     -126.96     2889.14 -168.72   -358.64 13.0       69587.80 -30096.10   7005.49     -125.03     2881.70 -138.49   -417.57 14.0       71617.00 -31412.90   7443.05     -120.37     2839.04 -95.47   -497.72 15.0       73320.90 -32442.90   7811.27     -117.59     2836.73 -78.55   -582.44 16.0       75078.70 -33504.10   8184.69     -111.70     2773.08 -28.70   -569.58 17.0       76605.90 -34256.30   8446.38     -106.43     2722.31   10.58   -648.37 18.0       78201.90 -35135.30   8779.71     -102.00     2687.99   34.04   -637.10 19.0       79683.00 -35825.50   9024.65       -96.68     2626.60   78.21   -644.17 20.0       81040.00 -36264.40   9175.96       -90.42     2571.71 105.53   -621.79 22.0       83842.80 -37347.80   9582.93       -79.77     2452.81 179.87   -678.83 24.0       86457.20 -37934.30   9779.99       -69.09     2348.63 223.29   -555.43 26.0       89143.70 -38488.40   9965.70       -58.22     2222.80 276.21   -541.65 28.0       91552.10 -38289.80   9775.89       -47.03     2083.59 328.54   -483.47 30.0       93976.80 -37775.30   9380.97       -35.17     1933.91 367.06   -412.13 35.0       99743.70 -35109.80   7937.17       -10.10     1701.23 242.55   -292.95 40.0       105747.00 -30710.40   5734.70       16.14     1409.70 -19.63   -330.25 Certificate of Compliance No. 1014                                      Amendment No. 12 Appendix B                                  2-57
Cooling Time (years)
Array/Class 15x15A/B/C A
B C
D E
F G
2.0 6771.99 897.63  
-45.95  
-155.96 1478.91  
-112.57  
-571.21 2.25 8543.84 862.70  
-53.16  
-148.35 1638.47  
-142.90  
-603.00 2.5 10454.10 757.88  
-56.51  
-143.91 1802.08  
-178.39  
-613.38 2.75 12589.40 536.75  
-50.58  
-136.31 1939.28  
-212.48  
-598.75 3.0 15043.50 106.18  
-18.51  
-127.37 2049.65  
-242.76  
-584.58 4.0 25256.40  
-2809.40 320.40  
-108.47 2382.23  
-339.78  
-246.30 5.0 34995.70  
-7157.77 1037.70  
-104.27 2547.85  
-373.57 64.26 6.0 43079.90  
-11755.40 1968.81  
-110.42 2669.55  
-367.08 207.73 7.0 49495.50  
-15880.10 2915.99  
-117.70 2745.06  
-335.00 79.17 8.0 54674.20  
-19541.50 3863.26  
-124.97 2823.26  
-307.52  
-139.52 9.0 58746.90  
-22465.30 4666.71  
-128.88 2870.36  
-274.05  
-284.74 10.0 62159.00  
-24900.00 5358.04  
-129.81 2882.28  
-231.65  
-307.41 11.0 64980.00  
-26916.40 5974.92  
-128.99 2890.02  
-197.70  
-320.91 12.0 67449.80  
-28657.30 6533.20  
-126.96 2889.14  
-168.72  
-358.64 13.0 69587.80  
-30096.10 7005.49  
-125.03 2881.70  
-138.49  
-417.57 14.0 71617.00  
-31412.90 7443.05  
-120.37 2839.04  
-95.47  
-497.72 15.0 73320.90  
-32442.90 7811.27  
-117.59 2836.73  
-78.55  
-582.44 16.0 75078.70  
-33504.10 8184.69  
-111.70 2773.08  
-28.70  
-569.58 17.0 76605.90  
-34256.30 8446.38  
-106.43 2722.31 10.58  
-648.37 18.0 78201.90  
-35135.30 8779.71  
-102.00 2687.99 34.04  
-637.10 19.0 79683.00  
-35825.50 9024.65  
-96.68 2626.60 78.21  
-644.17 20.0 81040.00  
-36264.40 9175.96  
-90.42 2571.71 105.53  
-621.79 22.0 83842.80  
-37347.80 9582.93  
-79.77 2452.81 179.87  
-678.83 24.0 86457.20  
-37934.30 9779.99  
-69.09 2348.63 223.29  
-555.43 26.0 89143.70  
-38488.40 9965.70  
-58.22 2222.80 276.21  
-541.65 28.0 91552.10  
-38289.80 9775.89  
-47.03 2083.59 328.54  
-483.47 30.0 93976.80  
-37775.30 9380.97  
-35.17 1933.91 367.06  
-412.13 35.0 99743.70  
-35109.80 7937.17  
-10.10 1701.23 242.55  
-292.95 40.0 105747.00  
-30710.40 5734.70 16.14 1409.70  
-19.63  
-330.25  


Approved Contents 2.0 Table 2.4-3 (Page 5 of 8)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-58 Table 2.4-3 (Page 5 of 8)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling                                 Array/Class 15x15D/E/F/H/I Time (years)          A         B           C             D           E       F       G 2.0       6290.79   883.39     -49.29       -150.42     1348.67 -93.23   -194.84 2.25       7850.16   906.09     -62.37       -145.85     1507.07 -121.33   -234.20 2.5       9917.64   729.63     -57.61       -138.51     1649.34 -150.19   -389.61 2.75       12039.70   498.88     -50.28       -132.19     1776.46 -179.02   -384.86 3.0       14308.20   140.88     -27.37       -126.11     1896.47 -208.80   -424.35 4.0       24246.40   -2585.64   274.38       -105.96     2197.31 -292.15   -98.88 5.0       33660.00   -6672.88   931.23       -104.57     2380.99 -330.06   323.27 6.0       41534.90 -11039.20   1790.84       -111.20     2485.37 -318.04   436.06 7.0       47737.40 -14940.00   2668.46       -119.75     2572.84 -293.94   394.87 8.0       52510.40 -18097.60   3446.19       -126.75     2647.38 -274.16   310.51 9.0       56484.50 -20845.30   4162.00       -129.08     2662.71 -225.75   158.84 10.0       59692.00 -23093.90   4799.05       -130.53     2692.07 -199.57   18.86 11.0       62307.70 -24865.90   5320.34       -130.34     2710.88 -176.52   -96.66 12.0       64497.20 -26247.00   5725.38       -127.89     2691.98 -137.42   -152.99 13.0       66473.70 -27479.90   6111.71       -124.64     2678.39 -110.34   -220.62 14.0       68322.50 -28605.10   6471.87       -120.12     2648.26 -78.83   -317.16 15.0       69880.10 -29416.90   6732.96       -115.83     2620.06 -52.26   -351.02 16.0       71504.30 -30337.40   7046.36       -110.89     2583.27 -22.60   -386.91 17.0       72938.30 -31008.00   7269.02       -105.81     2541.55   5.22   -421.21 18.0       74306.50 -31601.90   7471.26       -100.67     2498.95   31.67   -421.69 19.0       75649.10 -32149.50   7661.36         -95.47     2449.77   61.38   -439.23 20.0       76868.40 -32525.30   7793.09         -90.99     2421.09   73.14   -450.75 22.0       79592.40 -33604.00   8197.86         -78.90     2293.07 142.14   -486.11 24.0       81996.10 -34015.70   8295.91         -67.98     2173.93 196.55   -435.49 26.0       84232.50 -34067.60   8271.85         -57.61     2083.11 215.81   -374.64 28.0       86620.60 -34049.50   8171.94         -45.82     1954.61 249.73   -400.41 30.0       88983.60 -33826.80   8026.95         -34.27     1835.41 255.33   -353.18 35.0       94579.10 -31817.80   7120.43         -8.81     1596.94 131.34   -263.56 40.0       100058.00 -27653.80   5318.64         17.12     1355.45 -187.62   -273.88 Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-58
Cooling Time (years)
Array/Class 15x15D/E/F/H/I A
B C
D E
F G
2.0 6290.79 883.39  
-49.29  
-150.42 1348.67  
-93.23  
-194.84 2.25 7850.16 906.09  
-62.37  
-145.85 1507.07  
-121.33  
-234.20 2.5 9917.64 729.63  
-57.61  
-138.51 1649.34  
-150.19  
-389.61 2.75 12039.70 498.88  
-50.28  
-132.19 1776.46  
-179.02  
-384.86 3.0 14308.20 140.88  
-27.37  
-126.11 1896.47  
-208.80  
-424.35 4.0 24246.40  
-2585.64 274.38  
-105.96 2197.31  
-292.15  
-98.88 5.0 33660.00  
-6672.88 931.23  
-104.57 2380.99  
-330.06 323.27 6.0 41534.90  
-11039.20 1790.84  
-111.20 2485.37  
-318.04 436.06 7.0 47737.40  
-14940.00 2668.46  
-119.75 2572.84  
-293.94 394.87 8.0 52510.40  
-18097.60 3446.19  
-126.75 2647.38  
-274.16 310.51 9.0 56484.50  
-20845.30 4162.00  
-129.08 2662.71  
-225.75 158.84 10.0 59692.00  
-23093.90 4799.05  
-130.53 2692.07  
-199.57 18.86 11.0 62307.70  
-24865.90 5320.34  
-130.34 2710.88  
-176.52  
-96.66 12.0 64497.20  
-26247.00 5725.38  
-127.89 2691.98  
-137.42  
-152.99 13.0 66473.70  
-27479.90 6111.71  
-124.64 2678.39  
-110.34  
-220.62 14.0 68322.50  
-28605.10 6471.87  
-120.12 2648.26  
-78.83  
-317.16 15.0 69880.10  
-29416.90 6732.96  
-115.83 2620.06  
-52.26  
-351.02 16.0 71504.30  
-30337.40 7046.36  
-110.89 2583.27  
-22.60  
-386.91 17.0 72938.30  
-31008.00 7269.02  
-105.81 2541.55 5.22  
-421.21 18.0 74306.50  
-31601.90 7471.26  
-100.67 2498.95 31.67  
-421.69 19.0 75649.10  
-32149.50 7661.36  
-95.47 2449.77 61.38  
-439.23 20.0 76868.40  
-32525.30 7793.09  
-90.99 2421.09 73.14  
-450.75 22.0 79592.40  
-33604.00 8197.86  
-78.90 2293.07 142.14  
-486.11 24.0 81996.10  
-34015.70 8295.91  
-67.98 2173.93 196.55  
-435.49 26.0 84232.50  
-34067.60 8271.85  
-57.61 2083.11 215.81  
-374.64 28.0 86620.60  
-34049.50 8171.94  
-45.82 1954.61 249.73  
-400.41 30.0 88983.60  
-33826.80 8026.95  
-34.27 1835.41 255.33  
-353.18 35.0 94579.10  
-31817.80 7120.43  
-8.81 1596.94 131.34  
-263.56 40.0 100058.00  
-27653.80 5318.64 17.12 1355.45  
-187.62  
-273.88  


Approved Contents 2.0 Table 2.4-3 (Page 6 of 8)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-59 Table 2.4-3 (Page 6 of 8)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling                                     Array/Class 16X16A Time (years)        A           B         C             D           E       F         G 2.0       7213.94     1062.48     -60.18       -163.16     1632.73 -137.39   -660.90 2.25       9068.86     1052.65     -73.90       -157.12     1812.61 -174.53   -682.57 2.5       11282.40     881.74     -74.10       -149.28     1970.43 -212.23   -710.99 2.75       13602.30     625.18     -68.06       -143.44     2124.68 -253.65   -734.52 3.0       16226.30     143.97     -32.51       -136.73     2255.52 -291.73   -699.79 4.0       27528.60   -3346.42     393.54       -115.66     2587.71 -397.43   -273.55 5.0       38357.70   -8605.59   1312.06       -110.58     2719.25 -409.35     60.77 6.0       47353.00   -14184.20   2511.45       -117.96     2810.98 -373.58     26.38 7.0       54492.70   -19227.40   3751.22       -126.74     2889.14 -321.58   -84.61 8.0       60159.30   -23487.00   4884.62       -133.44     2918.29 -242.53   -126.66 9.0       64663.30   -26994.20   5900.01       -137.02     2946.64 -181.25   -285.69 10.0       68346.00   -29851.40   6755.60       -138.49     2958.18 -120.30   -384.11 11.0       71361.10   -32184.10   7502.54       -138.40     2964.72 -68.91   -497.04 12.0       74014.20   -34136.30   8127.59       -135.73     2938.32   -7.78   -627.98 13.0       76326.40   -35820.10   8697.58       -132.72     2908.57   49.64   -715.32 14.0       78450.30   -37288.70   9197.21       -128.85     2871.70 104.32   -771.96 15.0       80439.10   -38636.00   9667.15       -124.14     2815.86 168.64   -851.14 16.0       82142.00   -39610.20   10013.20       -120.20     2790.66 203.72   -859.48 17.0       83886.70   -40590.10   10336.30       -114.04     2714.78 270.50   -870.62 18.0       85580.90   -41545.60   10677.80       -108.53     2648.66 332.69   -921.15 19.0       87028.10   -42030.60   10787.80       -102.57     2576.39 390.15   -880.17 20.0       88490.60   -42584.60   10956.70       -97.67     2529.96 430.91   -912.08 22.0       91586.50   -43770.60   11272.60       -85.21     2343.82 579.90   -878.01 24.0       94293.80   -44158.40   11248.70       -74.44     2224.40 656.22   -824.58 26.0       97086.50   -44420.30   11078.90       -62.82     2045.62 784.53   -737.98 28.0       99965.10   -44515.00   10777.60       -51.29     1871.32 897.77   -719.30 30.0     102352.00   -43418.60   9831.79       -40.46     1725.50 957.49   -626.62 35.0     109039.00   -40353.50   7075.81       -12.07     1286.03 1106.60   -531.72 40.0     115345.00   -34020.20   2448.15       13.49       928.92 963.44   -395.64 Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-59
Cooling Time (years)
Array/Class 16X16A A
B C
D E
F G
2.0 7213.94 1062.48  
-60.18  
-163.16 1632.73  
-137.39  
-660.90 2.25 9068.86 1052.65  
-73.90  
-157.12 1812.61  
-174.53  
-682.57 2.5 11282.40 881.74  
-74.10  
-149.28 1970.43  
-212.23  
-710.99 2.75 13602.30 625.18  
-68.06  
-143.44 2124.68  
-253.65  
-734.52 3.0 16226.30 143.97  
-32.51  
-136.73 2255.52  
-291.73  
-699.79 4.0 27528.60  
-3346.42 393.54  
-115.66 2587.71  
-397.43  
-273.55 5.0 38357.70  
-8605.59 1312.06  
-110.58 2719.25  
-409.35 60.77 6.0 47353.00  
-14184.20 2511.45  
-117.96 2810.98  
-373.58 26.38 7.0 54492.70  
-19227.40 3751.22  
-126.74 2889.14  
-321.58  
-84.61 8.0 60159.30  
-23487.00 4884.62  
-133.44 2918.29  
-242.53  
-126.66 9.0 64663.30  
-26994.20 5900.01  
-137.02 2946.64  
-181.25  
-285.69 10.0 68346.00  
-29851.40 6755.60  
-138.49 2958.18  
-120.30  
-384.11 11.0 71361.10  
-32184.10 7502.54  
-138.40 2964.72  
-68.91  
-497.04 12.0 74014.20  
-34136.30 8127.59  
-135.73 2938.32  
-7.78  
-627.98 13.0 76326.40  
-35820.10 8697.58  
-132.72 2908.57 49.64  
-715.32 14.0 78450.30  
-37288.70 9197.21  
-128.85 2871.70 104.32  
-771.96 15.0 80439.10  
-38636.00 9667.15  
-124.14 2815.86 168.64  
-851.14 16.0 82142.00  
-39610.20 10013.20  
-120.20 2790.66 203.72  
-859.48 17.0 83886.70  
-40590.10 10336.30  
-114.04 2714.78 270.50  
-870.62 18.0 85580.90  
-41545.60 10677.80  
-108.53 2648.66 332.69  
-921.15 19.0 87028.10  
-42030.60 10787.80  
-102.57 2576.39 390.15  
-880.17 20.0 88490.60  
-42584.60 10956.70  
-97.67 2529.96 430.91  
-912.08 22.0 91586.50  
-43770.60 11272.60  
-85.21 2343.82 579.90  
-878.01 24.0 94293.80  
-44158.40 11248.70  
-74.44 2224.40 656.22  
-824.58 26.0 97086.50  
-44420.30 11078.90  
-62.82 2045.62 784.53  
-737.98 28.0 99965.10  
-44515.00 10777.60  
-51.29 1871.32 897.77  
-719.30 30.0 102352.00  
-43418.60 9831.79  
-40.46 1725.50 957.49  
-626.62 35.0 109039.00  
-40353.50 7075.81  
-12.07 1286.03 1106.60  
-531.72 40.0 115345.00  
-34020.20 2448.15 13.49 928.92 963.44  
-395.64  


Approved Contents 2.0 Table 2.4-3 (Page 7 of 8)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-60 Table 2.4-3 (Page 7 of 8)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling                               Array/Class 17x17A/16x16B/C Time (years)        A         B           C             D           E       F       G 2.0       7482.84     749.18     -32.06       -153.69     1490.54 -111.64   -301.94 2.25       9138.06     783.14     -45.73       -148.43     1678.27 -147.42   -271.38 2.5       11115.90   682.88     -49.46       -143.38     1855.10 -184.65   -248.90 2.75       13492.40   392.81     -34.32       -137.63     2018.42 -224.60   -364.95 3.0       15985.10     3.54       -9.05       -128.84     2149.50 -260.42   -263.00 4.0       27326.30   -3316.13   388.73       -110.89     2545.62 -376.10   -60.44 5.0       38630.20   -8729.17   1335.65       -109.86     2754.84 -407.49   244.70 6.0       48364.20 -14788.30   2652.90       -117.55     2878.88 -375.72   252.15 7.0       56144.10 -20415.70   4068.96       -128.12     2970.68 -312.43   -145.42 8.0       62319.20 -25122.10   5332.37       -133.94     2986.20 -212.65   -192.32 9.0       67097.40 -28916.30   6441.26       -139.07     3028.70 -142.12   -304.90 10.0       71141.80 -32210.80   7461.17       -140.60     3037.68 -63.75   -484.40 11.0       74293.50 -34623.40   8214.63       -140.16     3026.35   11.71   -567.89 12.0       77101.60 -36783.10   8922.19       -138.37     3008.48   83.17   -677.97 13.0       79705.10 -38760.90   9576.13       -134.21     2949.33 173.71   -820.83 14.0       81840.20 -40208.40 10063.30       -130.61     2915.99 236.79   -867.80 15.0       83845.30 -41560.10 10535.80       -126.12     2867.51 306.60   -940.08 16.0       85751.10 -42671.70 10876.60       -120.77     2799.15 386.28   -990.12 17.0       87613.20 -43744.30 11214.60       -114.75     2722.88 466.15 -1028.96 18.0       89198.60 -44487.50 11451.40       -110.00     2673.61 522.32   -974.28 19.0       90843.80 -45204.50 11637.70       -103.89     2591.93 602.99 -1048.14 20.0       92361.20 -45701.20 11710.50         -98.45     2507.40 689.65 -1034.50 22.0       95455.20 -46715.70 11886.10         -86.86     2353.10 835.28 -1006.44 24.0       98319.40 -46988.20 11622.80         -74.63     2169.86 995.06   -941.81 26.0       101240.00 -47039.80 11136.00         -62.32     1971.79 1168.97   -907.73 28.0       103863.00 -46243.10 10186.30         -51.51     1822.28 1270.39   -758.20 30.0       106638.00 -45299.90   9011.04         -39.38     1598.42 1447.93   -698.69 35.0       113059.00 -40056.10   4113.55         -12.17     1169.02 1660.44   -557.52 40.0       119131.00 -30799.70   -3521.78       14.35       791.94 1564.09   -401.82 Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    2-60
Cooling Time (years)
Array/Class 17x17A/16x16B/C A
B C
D E
F G
2.0 7482.84 749.18  
-32.06  
-153.69 1490.54  
-111.64  
-301.94 2.25 9138.06 783.14  
-45.73  
-148.43 1678.27  
-147.42  
-271.38 2.5 11115.90 682.88  
-49.46  
-143.38 1855.10  
-184.65  
-248.90 2.75 13492.40 392.81  
-34.32  
-137.63 2018.42  
-224.60  
-364.95 3.0 15985.10 3.54  
-9.05  
-128.84 2149.50  
-260.42  
-263.00 4.0 27326.30  
-3316.13 388.73  
-110.89 2545.62  
-376.10  
-60.44 5.0 38630.20  
-8729.17 1335.65  
-109.86 2754.84  
-407.49 244.70 6.0 48364.20  
-14788.30 2652.90  
-117.55 2878.88  
-375.72 252.15 7.0 56144.10  
-20415.70 4068.96  
-128.12 2970.68  
-312.43  
-145.42 8.0 62319.20  
-25122.10 5332.37  
-133.94 2986.20  
-212.65  
-192.32 9.0 67097.40  
-28916.30 6441.26  
-139.07 3028.70  
-142.12  
-304.90 10.0 71141.80  
-32210.80 7461.17  
-140.60 3037.68  
-63.75  
-484.40 11.0 74293.50  
-34623.40 8214.63  
-140.16 3026.35 11.71  
-567.89 12.0 77101.60  
-36783.10 8922.19  
-138.37 3008.48 83.17  
-677.97 13.0 79705.10  
-38760.90 9576.13  
-134.21 2949.33 173.71  
-820.83 14.0 81840.20  
-40208.40 10063.30  
-130.61 2915.99 236.79  
-867.80 15.0 83845.30  
-41560.10 10535.80  
-126.12 2867.51 306.60  
-940.08 16.0 85751.10  
-42671.70 10876.60  
-120.77 2799.15 386.28  
-990.12 17.0 87613.20  
-43744.30 11214.60  
-114.75 2722.88 466.15  
-1028.96 18.0 89198.60  
-44487.50 11451.40  
-110.00 2673.61 522.32  
-974.28 19.0 90843.80  
-45204.50 11637.70  
-103.89 2591.93 602.99  
-1048.14 20.0 92361.20  
-45701.20 11710.50  
-98.45 2507.40 689.65  
-1034.50 22.0 95455.20  
-46715.70 11886.10  
-86.86 2353.10 835.28  
-1006.44 24.0 98319.40  
-46988.20 11622.80  
-74.63 2169.86 995.06  
-941.81 26.0 101240.00  
-47039.80 11136.00  
-62.32 1971.79 1168.97  
-907.73 28.0 103863.00  
-46243.10 10186.30  
-51.51 1822.28 1270.39  
-758.20 30.0 106638.00  
-45299.90 9011.04  
-39.38 1598.42 1447.93  
-698.69 35.0 113059.00  
-40056.10 4113.55  
-12.17 1169.02 1660.44  
-557.52 40.0 119131.00  
-30799.70  
-3521.78 14.35 791.94 1564.09  
-401.82  


Approved Contents 2.0 Table 2.4-3 (Page 8 of 8)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-61 Table 2.4-3 (Page 8 of 8)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling                                   Array/Class 17x17B/C Time (years)        A           B         C             D         E         F       G 2.0       6766.33     744.89     -33.96       -154.11     1387.05 -99.30   -455.94 2.25       8406.78     735.84     -42.13       -148.76     1546.40 -127.76   -412.22 2.5       10326.00   618.40     -42.67       -140.84     1696.17 -158.83   -428.21 2.75       12425.70   400.95     -35.11       -134.79     1833.92 -190.65   -448.69 3.0       14787.40     16.36     -8.09       -128.41     1953.16 -221.24   -426.08 4.0       25076.00   -2855.35   319.19       -107.73     2268.19 -307.82   -118.54 5.0       34842.80   -7144.52   1015.11       -107.42     2457.65 -342.14   294.08 6.0       43259.40 -11920.40   1970.81       -113.08     2547.52 -316.78   82.08 7.0       49884.40 -16230.60   2962.56       -122.92     2650.94 -291.11   127.95 8.0       55105.20 -19804.80   3845.74       -128.64     2682.52 -232.47   -61.87 9.0       59268.90 -22820.00   4674.45       -133.56     2742.72 -203.91   -265.03 10.0       62653.20 -25227.80   5347.65       -134.19     2744.28 -150.34   -229.28 11.0       65528.50 -27328.80   5990.85       -134.07     2759.67 -117.12   -349.73 12.0       67925.00 -28930.10   6470.25       -131.66     2738.04 -69.75   -467.93 13.0       70014.00 -30295.30   6903.21       -128.41     2714.49 -27.74   -580.42 14.0       71939.40 -31542.90   7318.09       -124.70     2688.09   8.93   -630.83 15.0       73678.50 -32578.30   7669.57       -120.41     2659.19   41.04   -637.54 16.0       75313.80 -33488.20   7973.96       -115.46     2610.74   86.53   -708.01 17.0       76870.20 -34276.40   8238.11       -110.15     2563.22 123.29   -739.52 18.0       78338.30 -34971.50   8477.60       -104.26     2505.00 166.49   -731.14 19.0       79849.90 -35703.80   8726.57       -99.14     2447.13 211.29   -756.38 20.0       81109.20 -36047.10   8827.48       -93.99     2404.21 235.46   -751.74 22.0       83793.40 -36898.90   9088.73       -82.74     2281.57 313.80   -704.73 24.0       86424.70 -37453.70   9205.18       -70.11     2134.35 393.96   -654.44 26.0       88971.30 -37671.00   9134.01       -58.64     1983.82 478.46   -659.93 28.0       91497.60 -37723.60   9032.79       -47.61     1861.20 520.75   -564.47 30.0       93706.20 -36961.70   8512.11       -37.17     1743.83 543.52   -523.93 35.0       99798.50 -34670.70   6911.55         -9.53     1376.43 593.61   -406.67 40.0       105384.00 -29185.20   3708.34         16.92     1086.25 354.06   -343.59 Certificate of Compliance No. 1014                                      Amendment No. 12 Appendix B                                  2-61
Cooling Time (years)
Array/Class 17x17B/C A
B C
D E
F G
2.0 6766.33 744.89  
-33.96  
-154.11 1387.05  
-99.30  
-455.94 2.25 8406.78 735.84  
-42.13  
-148.76 1546.40  
-127.76  
-412.22 2.5 10326.00 618.40  
-42.67  
-140.84 1696.17  
-158.83  
-428.21 2.75 12425.70 400.95  
-35.11  
-134.79 1833.92  
-190.65  
-448.69 3.0 14787.40 16.36  
-8.09  
-128.41 1953.16  
-221.24  
-426.08 4.0 25076.00  
-2855.35 319.19  
-107.73 2268.19  
-307.82  
-118.54 5.0 34842.80  
-7144.52 1015.11  
-107.42 2457.65  
-342.14 294.08 6.0 43259.40  
-11920.40 1970.81  
-113.08 2547.52  
-316.78 82.08 7.0 49884.40  
-16230.60 2962.56  
-122.92 2650.94  
-291.11 127.95 8.0 55105.20  
-19804.80 3845.74  
-128.64 2682.52  
-232.47  
-61.87 9.0 59268.90  
-22820.00 4674.45  
-133.56 2742.72  
-203.91  
-265.03 10.0 62653.20  
-25227.80 5347.65  
-134.19 2744.28  
-150.34  
-229.28 11.0 65528.50  
-27328.80 5990.85  
-134.07 2759.67  
-117.12  
-349.73 12.0 67925.00  
-28930.10 6470.25  
-131.66 2738.04  
-69.75  
-467.93 13.0 70014.00  
-30295.30 6903.21  
-128.41 2714.49  
-27.74  
-580.42 14.0 71939.40  
-31542.90 7318.09  
-124.70 2688.09 8.93  
-630.83 15.0 73678.50  
-32578.30 7669.57  
-120.41 2659.19 41.04  
-637.54 16.0 75313.80  
-33488.20 7973.96  
-115.46 2610.74 86.53  
-708.01 17.0 76870.20  
-34276.40 8238.11  
-110.15 2563.22 123.29  
-739.52 18.0 78338.30  
-34971.50 8477.60  
-104.26 2505.00 166.49  
-731.14 19.0 79849.90  
-35703.80 8726.57  
-99.14 2447.13 211.29  
-756.38 20.0 81109.20  
-36047.10 8827.48  
-93.99 2404.21 235.46  
-751.74 22.0 83793.40  
-36898.90 9088.73  
-82.74 2281.57 313.80  
-704.73 24.0 86424.70  
-37453.70 9205.18  
-70.11 2134.35 393.96  
-654.44 26.0 88971.30  
-37671.00 9134.01  
-58.64 1983.82 478.46  
-659.93 28.0 91497.60  
-37723.60 9032.79  
-47.61 1861.20 520.75  
-564.47 30.0 93706.20  
-36961.70 8512.11  
-37.17 1743.83 543.52  
-523.93 35.0 99798.50  
-34670.70 6911.55  
-9.53 1376.43 593.61  
-406.67 40.0 105384.00  
-29185.20 3708.34 16.92 1086.25 354.06  
-343.59  


Approved Contents 2.0 Table 2.4-4 (Page 1 of 10)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-62 Table 2.4-4 (Page 1 of 10)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling Time                                 Array/Class 7x7B & 10x10F (years)          A           B           C             D           E       F         G 2.0       15761.10   10171.40   -1983.74       -180.41     4533.44 -1035.69 -1020.71 2.25       20683.90   10100.50   -2362.96       -171.37     4924.21 -1259.16 -1149.28 2.5       25710.50   9847.51   -2788.08       -162.18     5329.88 -1548.05 -1048.31 2.75       31858.60   7767.18   -2661.83       -154.93     5675.76 -1804.31   -992.87 3.0       38703.40   4333.22   -2101.88       -144.94     5898.42 -1990.59 -1030.87 4.0       65948.40 -16991.70     3924.57       -118.43     6390.16 -2406.62   -614.30 5.0       90881.20 -47264.90   16771.40       -112.75     6498.93 -2241.12   -192.49 6.0       111776.00 -79261.50   33399.20       -115.32     6416.04 -1620.07   -84.57 7.0       127348.00 -107023.00   50534.70       -139.25     6848.43 -1458.29   -14.89 8.0       140072.00 -130028.00   65223.10       -144.93     6836.24 -857.79   -99.75 9.0       150749.00 -150213.00   79005.50       -147.77     6773.51 -231.87   -331.15 10.0       158943.00 -167178.00   92612.70       -164.66     7287.36 -461.83   -382.12 11.0       165714.00 -179168.00   101557.00       -164.07     7241.92   -45.10   -521.50 12.0       171975.00 -190727.00   110548.00       -161.09     7166.19   380.43   -589.16 13.0       177624.00 -200947.00   118921.00       -158.82     7131.17   664.17   -667.75 14.0       182802.00 -210117.00   126526.00       -154.60     7016.50 1083.45   -747.88 15.0       186884.00 -214518.00   128584.00       -147.82     6809.36 1591.41   -783.35 16.0       191316.00 -221293.00   134071.00       -142.04     6646.92 2019.29   -841.16 17.0       195369.00 -231600.00   147624.00       -158.43     7404.40   946.55   -820.02 18.0       199404.00 -236224.00   150408.00       -148.69     7053.70 1655.35   -883.27 19.0       203726.00 -243272.00   157476.00       -143.31     6936.71 1903.09   -895.71 20.0       206861.00 -245479.00   159023.00       -137.13     6829.41 2091.47   -903.40 22.0       213325.00 -250875.00   163825.00       -127.55     6623.17 2500.20   -800.98 24.0       220063.00 -255065.00   166460.00       -114.40     6330.37 2896.83   -803.85 26.0       226903.00 -262541.00   177379.00       -115.77     6627.51 2189.72   -651.65 28.0       234964.00 -270961.00   187677.00       -102.37     6255.46 2595.08   -735.34 30.0       241796.00 -272482.00   188002.00       -88.80     5779.54 3315.93   -731.24 35.0       257457.00 -265751.00   183333.00       -71.68     5676.93 1648.24   -511.23 40.0       282525.00 -292276.00   240288.00       -43.47     4948.25   152.96   -833.96 Certificate of Compliance No. 1014                                            Amendment No. 12 Appendix B                                      2-62
Cooling Time (years)
Array/Class 7x7B & 10x10F A
B C
D E
F G
2.0 15761.10 10171.40  
-1983.74  
-180.41 4533.44  
-1035.69  
-1020.71 2.25 20683.90 10100.50  
-2362.96  
-171.37 4924.21  
-1259.16  
-1149.28 2.5 25710.50 9847.51  
-2788.08  
-162.18 5329.88  
-1548.05  
-1048.31 2.75 31858.60 7767.18  
-2661.83  
-154.93 5675.76  
-1804.31  
-992.87 3.0 38703.40 4333.22  
-2101.88  
-144.94 5898.42  
-1990.59  
-1030.87 4.0 65948.40  
-16991.70 3924.57  
-118.43 6390.16  
-2406.62  
-614.30 5.0 90881.20  
-47264.90 16771.40  
-112.75 6498.93  
-2241.12  
-192.49 6.0 111776.00  
-79261.50 33399.20  
-115.32 6416.04  
-1620.07  
-84.57 7.0 127348.00  
-107023.00 50534.70  
-139.25 6848.43  
-1458.29  
-14.89 8.0 140072.00  
-130028.00 65223.10  
-144.93 6836.24  
-857.79  
-99.75 9.0 150749.00  
-150213.00 79005.50  
-147.77 6773.51  
-231.87  
-331.15 10.0 158943.00  
-167178.00 92612.70  
-164.66 7287.36  
-461.83  
-382.12 11.0 165714.00  
-179168.00 101557.00  
-164.07 7241.92  
-45.10  
-521.50 12.0 171975.00  
-190727.00 110548.00  
-161.09 7166.19 380.43  
-589.16 13.0 177624.00  
-200947.00 118921.00  
-158.82 7131.17 664.17  
-667.75 14.0 182802.00  
-210117.00 126526.00  
-154.60 7016.50 1083.45  
-747.88 15.0 186884.00  
-214518.00 128584.00  
-147.82 6809.36 1591.41  
-783.35 16.0 191316.00  
-221293.00 134071.00  
-142.04 6646.92 2019.29  
-841.16 17.0 195369.00  
-231600.00 147624.00  
-158.43 7404.40 946.55  
-820.02 18.0 199404.00  
-236224.00 150408.00  
-148.69 7053.70 1655.35  
-883.27 19.0 203726.00  
-243272.00 157476.00  
-143.31 6936.71 1903.09  
-895.71 20.0 206861.00  
-245479.00 159023.00  
-137.13 6829.41 2091.47  
-903.40 22.0 213325.00  
-250875.00 163825.00  
-127.55 6623.17 2500.20  
-800.98 24.0 220063.00  
-255065.00 166460.00  
-114.40 6330.37 2896.83  
-803.85 26.0 226903.00  
-262541.00 177379.00  
-115.77 6627.51 2189.72  
-651.65 28.0 234964.00  
-270961.00 187677.00  
-102.37 6255.46 2595.08  
-735.34 30.0 241796.00  
-272482.00 188002.00  
-88.80 5779.54 3315.93  
-731.24 35.0 257457.00  
-265751.00 183333.00  
-71.68 5676.93 1648.24  
-511.23 40.0 282525.00  
-292276.00 240288.00  
-43.47 4948.25 152.96  
-833.96  


Approved Contents 2.0 Table 2.4-4 (Page 2 of 10)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-63 Table 2.4-4 (Page 2 of 10)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling Time                                     Array/Class 8x8B (years)          A           B           C           D           E       F         G 2.0       15913.80   11664.70   -2480.99     -179.56     4694.73 -1100.00 -1003.87 2.25       20652.00   12023.80   -3025.66     -174.12     5204.92 -1412.29   -979.17 2.5       26986.10   10399.30   -3032.60     -163.94     5594.88 -1694.85 -1213.71 2.75       33074.30   8670.65   -3129.69     -156.84     5959.94 -1975.74 -1054.90 3.0       39987.50   5388.94   -2722.03     -146.15     6189.85 -2184.18 -1039.58 4.0       68821.60 -18071.10     4016.97     -119.21     6655.64 -2578.72   -677.77 5.0       95032.70 -50959.00   18228.50     -113.67     6737.08 -2341.46   -253.74 6.0       117864.00 -88879.60   39468.80     -128.75     6937.68 -1918.61   -203.01 7.0       133919.00 -117151.00   56431.30     -139.69     6960.80 -1212.83   -123.38 8.0       147621.00 -142952.00   73246.80     -143.67     6879.18 -441.73   -342.11 9.0       158036.00 -165478.00   90946.70     -167.32     7480.35 -551.45   -378.22 10.0       166796.00 -181378.00   101771.00     -165.98     7346.03   114.50   -504.04 11.0       174312.00 -195869.00   112810.00     -165.26     7291.07   642.48   -648.03 12.0       180736.00 -207916.00   122412.00     -163.34     7243.01 1055.04   -742.81 13.0       187002.00 -219945.00   132127.00     -159.70     7084.08 1641.84   -903.88 14.0       192382.00 -229413.00   139613.00     -156.32     7001.62 2085.84   -972.60 15.0       196087.00 -233618.00   142299.00     -151.48     6860.06 2570.55   -883.73 16.0       202268.00 -249608.00   159974.00     -162.80     7359.57 1999.93 -1048.13 17.0       206376.00 -256109.00   166401.00     -159.20     7309.03 2257.68 -1062.93 18.0       209117.00 -255071.00   162389.00     -151.82     7125.28 2596.49   -891.61 19.0       213124.00 -261295.00   168674.00     -146.82     7004.96 2966.11   -951.40 20.0       217047.00 -267281.00   175609.00     -141.96     6943.62 3118.99 -1012.59 22.0       223569.00 -268761.00   171389.00     -127.42     6436.52 4175.11   -877.23 24.0       233533.00 -291046.00   200512.00     -131.73     6830.33 3613.57   -988.74 26.0       238557.00 -284966.00   188216.00     -118.63     6424.02 4316.86   -862.50 28.0       245385.00 -285588.00   185055.00     -105.51     6116.61 4651.69   -844.39 30.0       254559.00 -295608.00   196106.00     -100.36     6027.39 4465.31   -886.90 35.0       272231.00 -295589.00   203313.00       -71.05     5259.94 4464.18   -744.47 40.0       290782.00 -286198.00   204311.00       -50.38     4868.38 2364.75   -614.59 Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      2-63
Cooling Time (years)
Array/Class 8x8B A
B C
D E
F G
2.0 15913.80 11664.70  
-2480.99  
-179.56 4694.73  
-1100.00  
-1003.87 2.25 20652.00 12023.80  
-3025.66  
-174.12 5204.92  
-1412.29  
-979.17 2.5 26986.10 10399.30  
-3032.60  
-163.94 5594.88  
-1694.85  
-1213.71 2.75 33074.30 8670.65  
-3129.69  
-156.84 5959.94  
-1975.74  
-1054.90 3.0 39987.50 5388.94  
-2722.03  
-146.15 6189.85  
-2184.18  
-1039.58 4.0 68821.60  
-18071.10 4016.97  
-119.21 6655.64  
-2578.72  
-677.77 5.0 95032.70  
-50959.00 18228.50  
-113.67 6737.08  
-2341.46  
-253.74 6.0 117864.00  
-88879.60 39468.80  
-128.75 6937.68  
-1918.61  
-203.01 7.0 133919.00  
-117151.00 56431.30  
-139.69 6960.80  
-1212.83  
-123.38 8.0 147621.00  
-142952.00 73246.80  
-143.67 6879.18  
-441.73  
-342.11 9.0 158036.00  
-165478.00 90946.70  
-167.32 7480.35  
-551.45  
-378.22 10.0 166796.00  
-181378.00 101771.00  
-165.98 7346.03 114.50  
-504.04 11.0 174312.00  
-195869.00 112810.00  
-165.26 7291.07 642.48  
-648.03 12.0 180736.00  
-207916.00 122412.00  
-163.34 7243.01 1055.04  
-742.81 13.0 187002.00  
-219945.00 132127.00  
-159.70 7084.08 1641.84  
-903.88 14.0 192382.00  
-229413.00 139613.00  
-156.32 7001.62 2085.84  
-972.60 15.0 196087.00  
-233618.00 142299.00  
-151.48 6860.06 2570.55  
-883.73 16.0 202268.00  
-249608.00 159974.00  
-162.80 7359.57 1999.93  
-1048.13 17.0 206376.00  
-256109.00 166401.00  
-159.20 7309.03 2257.68  
-1062.93 18.0 209117.00  
-255071.00 162389.00  
-151.82 7125.28 2596.49  
-891.61 19.0 213124.00  
-261295.00 168674.00  
-146.82 7004.96 2966.11  
-951.40 20.0 217047.00  
-267281.00 175609.00  
-141.96 6943.62 3118.99  
-1012.59 22.0 223569.00  
-268761.00 171389.00  
-127.42 6436.52 4175.11  
-877.23 24.0 233533.00  
-291046.00 200512.00  
-131.73 6830.33 3613.57  
-988.74 26.0 238557.00  
-284966.00 188216.00  
-118.63 6424.02 4316.86  
-862.50 28.0 245385.00  
-285588.00 185055.00  
-105.51 6116.61 4651.69  
-844.39 30.0 254559.00  
-295608.00 196106.00  
-100.36 6027.39 4465.31  
-886.90 35.0 272231.00  
-295589.00 203313.00  
-71.05 5259.94 4464.18  
-744.47 40.0 290782.00  
-286198.00 204311.00  
-50.38 4868.38 2364.75  
-614.59  


Approved Contents 2.0 Table 2.4-4 (Page 3 of 10)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-64 Table 2.4-4 (Page 3 of 10)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling Time                                   Array/Class 8x8C/D/E (years)          A           B           C             D           E       F         G 2.0       16663.00   10889.80   -2211.52       -182.17     4831.25 -1175.27 -1260.49 2.25       21598.90   10980.20   -2691.18       -176.65     5300.72 -1453.46 -1219.04 2.5       27348.40   10071.30   -2967.33       -165.41     5680.31 -1735.86 -1252.79 2.75       33467.10   8232.39   -2999.52       -158.56     6061.56 -2033.93 -1086.98 3.0       40382.30   4849.42   -2525.53       -148.53     6314.10 -2257.89 -1075.95 4.0       68954.10 -18263.30     4048.93       -123.13     6850.62 -2734.70   -652.59 5.0       96324.30 -53730.10   19778.60       -114.90     6841.59 -2381.30   -353.71 6.0       118229.00 -89906.60   39997.30       -134.45     7190.60 -2120.86   -143.41 7.0       134948.00 -119919.00   58227.10       -143.18     7200.03 -1397.69   -170.37 8.0       149092.00 -147517.00   76590.50       -149.16     7110.00 -528.97   -313.19 9.0       159771.00 -170139.00   93968.00       -170.19     7649.69 -595.38   -403.04 10.0       168715.00 -187828.00   107088.00       -172.19     7651.82   -46.57   -555.81 11.0       176169.00 -201821.00   117349.00       -170.83     7550.84   552.84   -651.76 12.0       182662.00 -214445.00   127628.00       -169.36     7519.56   997.32   -756.73 13.0       189114.00 -227085.00   137699.00       -166.11     7388.07 1583.27   -844.97 14.0       195273.00 -239345.00   148361.00       -160.79     7228.22 2124.28 -1017.11 15.0       199939.00 -249862.00   159949.00       -174.10     7782.47 1566.35 -1026.32 16.0       204899.00 -258274.00   166856.00       -167.77     7534.06 2227.05 -1070.51 17.0       209356.00 -265290.00   173458.00       -161.96     7463.49 2386.89 -1040.14 18.0       213546.00 -272476.00   180667.00       -158.41     7387.49 2763.66 -1098.37 19.0       217506.00 -277100.00   183949.00       -150.21     7155.18 3240.82 -1107.07 20.0       219837.00 -275266.00   179705.00       -145.05     7009.96 3638.55 -1007.16 22.0       228092.00 -285272.00   186688.00       -133.55     6672.08 4473.64 -1122.87 24.0       237213.00 -304032.00   211958.00       -136.95     7000.92 4086.48 -1049.61 26.0       242060.00 -297359.00   199620.00       -125.83     6734.22 4465.79   -972.10 28.0       249432.00 -299622.00   196900.00       -111.26     6222.03 5440.43   -914.71 30.0       263307.00 -334844.00   247655.00       -111.83     6452.32 4775.31 -1191.53 35.0       273393.00 -291765.00   178985.00       -83.84     5736.80 4650.87   -621.35 40.0       293153.00 -283353.00   175255.00       -57.06     4937.79 3684.27   -559.25 Certificate of Compliance No. 1014                                            Amendment No. 12 Appendix B                                      2-64
Cooling Time (years)
Array/Class 8x8C/D/E A
B C
D E
F G
2.0 16663.00 10889.80  
-2211.52  
-182.17 4831.25  
-1175.27  
-1260.49 2.25 21598.90 10980.20  
-2691.18  
-176.65 5300.72  
-1453.46  
-1219.04 2.5 27348.40 10071.30  
-2967.33  
-165.41 5680.31  
-1735.86  
-1252.79 2.75 33467.10 8232.39  
-2999.52  
-158.56 6061.56  
-2033.93  
-1086.98 3.0 40382.30 4849.42  
-2525.53  
-148.53 6314.10  
-2257.89  
-1075.95 4.0 68954.10  
-18263.30 4048.93  
-123.13 6850.62  
-2734.70  
-652.59 5.0 96324.30  
-53730.10 19778.60  
-114.90 6841.59  
-2381.30  
-353.71 6.0 118229.00  
-89906.60 39997.30  
-134.45 7190.60  
-2120.86  
-143.41 7.0 134948.00  
-119919.00 58227.10  
-143.18 7200.03  
-1397.69  
-170.37 8.0 149092.00  
-147517.00 76590.50  
-149.16 7110.00  
-528.97  
-313.19 9.0 159771.00  
-170139.00 93968.00  
-170.19 7649.69  
-595.38  
-403.04 10.0 168715.00  
-187828.00 107088.00  
-172.19 7651.82  
-46.57  
-555.81 11.0 176169.00  
-201821.00 117349.00  
-170.83 7550.84 552.84  
-651.76 12.0 182662.00  
-214445.00 127628.00  
-169.36 7519.56 997.32  
-756.73 13.0 189114.00  
-227085.00 137699.00  
-166.11 7388.07 1583.27  
-844.97 14.0 195273.00  
-239345.00 148361.00  
-160.79 7228.22 2124.28  
-1017.11 15.0 199939.00  
-249862.00 159949.00  
-174.10 7782.47 1566.35  
-1026.32 16.0 204899.00  
-258274.00 166856.00  
-167.77 7534.06 2227.05  
-1070.51 17.0 209356.00  
-265290.00 173458.00  
-161.96 7463.49 2386.89  
-1040.14 18.0 213546.00  
-272476.00 180667.00  
-158.41 7387.49 2763.66  
-1098.37 19.0 217506.00  
-277100.00 183949.00  
-150.21 7155.18 3240.82  
-1107.07 20.0 219837.00  
-275266.00 179705.00  
-145.05 7009.96 3638.55  
-1007.16 22.0 228092.00  
-285272.00 186688.00  
-133.55 6672.08 4473.64  
-1122.87 24.0 237213.00  
-304032.00 211958.00  
-136.95 7000.92 4086.48  
-1049.61 26.0 242060.00  
-297359.00 199620.00  
-125.83 6734.22 4465.79  
-972.10 28.0 249432.00  
-299622.00 196900.00  
-111.26 6222.03 5440.43  
-914.71 30.0 263307.00  
-334844.00 247655.00  
-111.83 6452.32 4775.31  
-1191.53 35.0 273393.00  
-291765.00 178985.00  
-83.84 5736.80 4650.87  
-621.35 40.0 293153.00  
-283353.00 175255.00  
-57.06 4937.79 3684.27  
-559.25  


Approved Contents 2.0 Table 2.4-4 (Page 4 of 10)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-65 Table 2.4-4 (Page 4 of 10)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling Time                                     Array/Class 9x9A (years)          A           B           C           D           E       F         G 2.0       16564.30   12063.20   -2586.67     -184.87     4976.49 -1228.06   -894.91 2.25       22071.80   11834.70   -3015.91     -174.88     5443.22 -1518.94 -1014.33 2.5       27866.60   10993.50   -3286.54     -168.71     5965.88 -1909.06 -1027.88 2.75       34375.10   9004.62   -3367.62     -158.97     6305.05 -2182.06   -933.24 3.0       41566.50   5392.11   -2800.23     -149.79     6613.45 -2462.36   -904.38 4.0       72006.50 -20264.40     4921.01     -123.85     7211.86 -3004.62   -603.22 5.0       100197.00 -57315.80   21669.60     -118.72     7356.33 -2796.24   -243.52 6.0       124367.00 -99348.10   46264.80     -136.71     7648.05 -2394.38   -67.58 7.0       143009.00 -134740.00   68824.10     -143.35     7544.90 -1403.30   -173.80 8.0       157479.00 -165996.00   92255.30     -168.05     8114.30 -1315.88   -266.71 9.0       169636.00 -191379.00   110928.00     -172.50     8069.55 -500.37   -450.57 10.0       179282.00 -211202.00   125969.00     -172.12     7976.57   283.36   -617.13 11.0       187512.00 -228637.00   140325.00     -172.16     7928.03   894.69   -760.39 12.0       195321.00 -245580.00   154682.00     -170.38     7824.20 1596.02   -863.97 13.0       202110.00 -263050.00   173293.00     -187.18     8470.09 1003.55   -953.17 14.0       208171.00 -274758.00   183332.00     -179.75     8249.83 1717.21 -1103.07 15.0       213590.00 -284590.00   191650.00     -175.64     8098.33 2289.04 -1165.13 16.0       218091.00 -292503.00   199557.00     -171.84     8035.82 2659.38 -1119.03 17.0       223491.00 -302449.00   208733.00     -164.92     7833.36 3192.21 -1255.80 18.0       226523.00 -304524.00   209895.00     -162.71     7829.04 3410.57 -1091.33 19.0       231702.00 -312496.00   215730.00     -153.73     7552.13 4052.91 -1189.12 20.0       236531.00 -324776.00   232293.00     -164.72     8073.05 3368.73 -1233.57 22.0       244888.00 -335452.00   241932.00     -150.44     7566.26 4642.58 -1160.69 24.0       252171.00 -340795.00   244542.00     -141.18     7321.23 5355.16 -1142.40 26.0       259438.00 -343494.00   244340.00     -129.66     7094.56 5645.82 -1119.92 28.0       268823.00 -359239.00   266068.00     -130.16     7204.93 5605.85 -1064.30 30.0       277221.00 -363922.00   268930.00     -116.96     6799.84 6219.78 -1037.79 35.0       294285.00 -351643.00   245914.00       -99.35     6404.25 5923.44   -713.23 40.0       324174.00 -389397.00   319233.00       -77.68     5933.52 3992.56 -1188.62 Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      2-65
Cooling Time (years)
Array/Class 9x9A A
B C
D E
F G
2.0 16564.30 12063.20  
-2586.67  
-184.87 4976.49  
-1228.06  
-894.91 2.25 22071.80 11834.70  
-3015.91  
-174.88 5443.22  
-1518.94  
-1014.33 2.5 27866.60 10993.50  
-3286.54  
-168.71 5965.88  
-1909.06  
-1027.88 2.75 34375.10 9004.62  
-3367.62  
-158.97 6305.05  
-2182.06  
-933.24 3.0 41566.50 5392.11  
-2800.23  
-149.79 6613.45  
-2462.36  
-904.38 4.0 72006.50  
-20264.40 4921.01  
-123.85 7211.86  
-3004.62  
-603.22 5.0 100197.00  
-57315.80 21669.60  
-118.72 7356.33  
-2796.24  
-243.52 6.0 124367.00  
-99348.10 46264.80  
-136.71 7648.05  
-2394.38  
-67.58 7.0 143009.00  
-134740.00 68824.10  
-143.35 7544.90  
-1403.30  
-173.80 8.0 157479.00  
-165996.00 92255.30  
-168.05 8114.30  
-1315.88  
-266.71 9.0 169636.00  
-191379.00 110928.00  
-172.50 8069.55  
-500.37  
-450.57 10.0 179282.00  
-211202.00 125969.00  
-172.12 7976.57 283.36  
-617.13 11.0 187512.00  
-228637.00 140325.00  
-172.16 7928.03 894.69  
-760.39 12.0 195321.00  
-245580.00 154682.00  
-170.38 7824.20 1596.02  
-863.97 13.0 202110.00  
-263050.00 173293.00  
-187.18 8470.09 1003.55  
-953.17 14.0 208171.00  
-274758.00 183332.00  
-179.75 8249.83 1717.21  
-1103.07 15.0 213590.00  
-284590.00 191650.00  
-175.64 8098.33 2289.04  
-1165.13 16.0 218091.00  
-292503.00 199557.00  
-171.84 8035.82 2659.38  
-1119.03 17.0 223491.00  
-302449.00 208733.00  
-164.92 7833.36 3192.21  
-1255.80 18.0 226523.00  
-304524.00 209895.00  
-162.71 7829.04 3410.57  
-1091.33 19.0 231702.00  
-312496.00 215730.00  
-153.73 7552.13 4052.91  
-1189.12 20.0 236531.00  
-324776.00 232293.00  
-164.72 8073.05 3368.73  
-1233.57 22.0 244888.00  
-335452.00 241932.00  
-150.44 7566.26 4642.58  
-1160.69 24.0 252171.00  
-340795.00 244542.00  
-141.18 7321.23 5355.16  
-1142.40 26.0 259438.00  
-343494.00 244340.00  
-129.66 7094.56 5645.82  
-1119.92 28.0 268823.00  
-359239.00 266068.00  
-130.16 7204.93 5605.85  
-1064.30 30.0 277221.00  
-363922.00 268930.00  
-116.96 6799.84 6219.78  
-1037.79 35.0 294285.00  
-351643.00 245914.00  
-99.35 6404.25 5923.44  
-713.23 40.0 324174.00  
-389397.00 319233.00  
-77.68 5933.52 3992.56  
-1188.62  


Approved Contents 2.0 Table 2.4-4 (Page 5 of 10)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-66 Table 2.4-4 (Page 5 of 10)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling Time                                     Array/Class 9x9B (years)          A           B           C           D           E       F         G 2.0       17186.80   11657.20   -2441.58     -183.45     5049.98 -1246.51 -1156.40 2.25       21800.20   12295.50   -3074.77     -180.94     5660.86 -1631.58 -1064.82 2.5       28010.00   11198.70   -3349.88     -169.84     6074.18 -1943.73 -1220.46 2.75       34607.80   9092.75   -3327.98     -161.55     6476.70 -2279.47 -1090.70 3.0       41425.40   6300.12   -3202.59     -151.95     6782.84 -2566.85 -1000.46 4.0       71942.80 -18734.90     3920.65     -125.38     7367.52 -3119.27   -631.75 5.0       101151.00 -57291.00   21182.10     -118.05     7377.24 -2721.50   -361.88 6.0       125823.00 -99944.80   45636.60     -136.47     7588.00 -2124.69   -262.67 7.0       144638.00 -135378.00   67687.60     -143.88     7447.72 -995.76   -340.94 8.0       159872.00 -168383.00   91921.20     -168.66     7933.70 -673.04   -395.74 9.0       172305.00 -194121.00   110332.00     -172.16     7831.09   301.31   -634.37 10.0       181683.00 -213140.00   124418.00     -173.36     7740.03 1165.16   -753.12 11.0       190922.00 -232977.00   140095.00     -171.28     7581.53 2053.29 -1027.00 12.0       198213.00 -248066.00   152236.00     -170.70     7492.96 2781.03 -1087.99 13.0       205947.00 -268590.00   173240.00     -187.42     8096.44 2390.78 -1199.48 14.0       211867.00 -280583.00   184192.00     -183.14     8023.23 2903.27 -1325.04 15.0       217071.00 -289407.00   190649.00     -177.77     7760.30 3819.17 -1355.68 16.0       221340.00 -294404.00   193178.00     -173.59     7653.54 4235.81 -1282.26 17.0       227205.00 -306489.00   204027.00     -164.96     7309.81 5290.73 -1440.44 18.0       231085.00 -310612.00   206608.00     -160.03     7176.88 5715.32 -1383.11 19.0       236345.00 -320398.00   215697.00     -153.84     7020.00 6284.82 -1522.44 20.0       240125.00 -328538.00   227545.00     -170.25     7836.24 5008.11 -1382.77 22.0       245672.00 -325279.00   216287.00     -158.18     7517.98 5919.63 -1187.15 24.0       256479.00 -345503.00   236771.00     -144.07     6970.57 7508.12 -1317.75 26.0       260950.00 -331434.00   205388.00     -130.57     6497.58 8638.70 -1076.78 28.0       269984.00 -343628.00   218366.00     -134.58     6861.68 8165.52 -1062.58 30.0       278259.00 -348285.00   221391.00     -123.31     6538.19 8720.28 -1076.88 35.0       297697.00 -344053.00   202586.00     -105.06     6094.38 9194.58   -852.15 40.0       331243.00 -401432.00   313358.00       -81.82     5561.33 7636.50 -1470.42 Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      2-66
Cooling Time (years)
Array/Class 9x9B A
B C
D E
F G
2.0 17186.80 11657.20  
-2441.58  
-183.45 5049.98  
-1246.51  
-1156.40 2.25 21800.20 12295.50  
-3074.77  
-180.94 5660.86  
-1631.58  
-1064.82 2.5 28010.00 11198.70  
-3349.88  
-169.84 6074.18  
-1943.73  
-1220.46 2.75 34607.80 9092.75  
-3327.98  
-161.55 6476.70  
-2279.47  
-1090.70 3.0 41425.40 6300.12  
-3202.59  
-151.95 6782.84  
-2566.85  
-1000.46 4.0 71942.80  
-18734.90 3920.65  
-125.38 7367.52  
-3119.27  
-631.75 5.0 101151.00  
-57291.00 21182.10  
-118.05 7377.24  
-2721.50  
-361.88 6.0 125823.00  
-99944.80 45636.60  
-136.47 7588.00  
-2124.69  
-262.67 7.0 144638.00  
-135378.00 67687.60  
-143.88 7447.72  
-995.76  
-340.94 8.0 159872.00  
-168383.00 91921.20  
-168.66 7933.70  
-673.04  
-395.74 9.0 172305.00  
-194121.00 110332.00  
-172.16 7831.09 301.31  
-634.37 10.0 181683.00  
-213140.00 124418.00  
-173.36 7740.03 1165.16  
-753.12 11.0 190922.00  
-232977.00 140095.00  
-171.28 7581.53 2053.29  
-1027.00 12.0 198213.00  
-248066.00 152236.00  
-170.70 7492.96 2781.03  
-1087.99 13.0 205947.00  
-268590.00 173240.00  
-187.42 8096.44 2390.78  
-1199.48 14.0 211867.00  
-280583.00 184192.00  
-183.14 8023.23 2903.27  
-1325.04 15.0 217071.00  
-289407.00 190649.00  
-177.77 7760.30 3819.17  
-1355.68 16.0 221340.00  
-294404.00 193178.00  
-173.59 7653.54 4235.81  
-1282.26 17.0 227205.00  
-306489.00 204027.00  
-164.96 7309.81 5290.73  
-1440.44 18.0 231085.00  
-310612.00 206608.00  
-160.03 7176.88 5715.32  
-1383.11 19.0 236345.00  
-320398.00 215697.00  
-153.84 7020.00 6284.82  
-1522.44 20.0 240125.00  
-328538.00 227545.00  
-170.25 7836.24 5008.11  
-1382.77 22.0 245672.00  
-325279.00 216287.00  
-158.18 7517.98 5919.63  
-1187.15 24.0 256479.00  
-345503.00 236771.00  
-144.07 6970.57 7508.12  
-1317.75 26.0 260950.00  
-331434.00 205388.00  
-130.57 6497.58 8638.70  
-1076.78 28.0 269984.00  
-343628.00 218366.00  
-134.58 6861.68 8165.52  
-1062.58 30.0 278259.00  
-348285.00 221391.00  
-123.31 6538.19 8720.28  
-1076.88 35.0 297697.00  
-344053.00 202586.00  
-105.06 6094.38 9194.58  
-852.15 40.0 331243.00  
-401432.00 313358.00  
-81.82 5561.33 7636.50  
-1470.42  


Approved Contents 2.0 Table 2.4-4 (Page 6 of 10)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-67 Table 2.4-4 (Page 6 of 10)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling Time                                   Array/Class 9x9C/D (years)          A           B           C             D           E       F         G 2.0       16691.80   11823.60   -2447.14       -185.99     5008.36 -1243.90 -1059.30 2.25       21740.60   12301.10   -3136.66       -173.22     5422.51 -1511.79 -1061.56 2.5       27709.70   11300.00   -3398.46       -167.10     5898.90 -1850.17 -1171.40 2.75       33988.10   9774.59   -3696.16       -158.15     6268.38 -2155.04   -974.14 3.0       41117.20   6515.41   -3381.03       -148.32     6548.78 -2413.74   -948.98 4.0       71428.60 -18297.80     3576.44       -123.51     7125.21 -2923.50   -632.21 5.0       100397.00 -56458.80   20611.70       -115.75     7125.58 -2528.06   -313.97 6.0       124283.00 -97234.10   43750.10       -135.36     7393.89 -2038.45   -178.07 7.0       142677.00 -131502.00   64937.90       -142.42     7276.64 -994.67   -255.89 8.0       158111.00 -164750.00   89150.00       -165.13     7682.79 -614.18   -382.56 9.0       169539.00 -187815.00   105688.00       -170.16     7701.54   95.21   -536.66 10.0       179168.00 -207560.00   120407.00       -172.05     7615.14   907.40   -757.15 11.0       187428.00 -224318.00   133228.00       -170.11     7472.64 1710.47   -885.30 12.0       195546.00 -241540.00   147050.00       -166.19     7281.30 2560.85 -1135.94 13.0       202256.00 -258699.00   164971.00       -182.40     7906.42 2044.37 -1182.19 14.0       207838.00 -268927.00   173192.00       -178.93     7770.91 2703.98 -1224.09 15.0       213979.00 -281611.00   184781.00       -172.75     7552.21 3409.13 -1276.86 16.0       217809.00 -285839.00   187221.00       -168.56     7458.11 3805.42 -1317.69 17.0       223749.00 -297214.00   196642.00       -160.86     7141.47 4676.19 -1362.21 18.0       226075.00 -295937.00   193130.00       -157.66     7127.19 4895.03 -1291.13 19.0       230997.00 -304670.00   201281.00       -150.53     6907.85 5558.32 -1353.07 20.0       238022.00 -324930.00   227066.00       -158.32     7284.25 5103.45 -1464.16 22.0       243676.00 -322706.00   217208.00       -147.77     6978.74 5979.30 -1239.05 24.0       251683.00 -332524.00   227486.00       -137.48     6744.91 6651.45 -1261.39 26.0       256408.00 -321812.00   204514.00       -125.79     6394.39 7373.18 -1135.32 28.0       264537.00 -330729.00   215269.00       -131.03     6864.20 6415.84 -1014.55 30.0       273958.00 -341208.00   225146.00       -115.29     6196.43 7947.39 -1073.39 35.0       292385.00 -333153.00   204415.00       -98.00     5956.86 7222.98   -860.79 40.0       329247.00 -419504.00   371883.00       -71.42     4943.73 7633.01 -1618.27 Certificate of Compliance No. 1014                                            Amendment No. 12 Appendix B                                      2-67
Cooling Time (years)
Array/Class 9x9C/D A
B C
D E
F G
2.0 16691.80 11823.60  
-2447.14  
-185.99 5008.36  
-1243.90  
-1059.30 2.25 21740.60 12301.10  
-3136.66  
-173.22 5422.51  
-1511.79  
-1061.56 2.5 27709.70 11300.00  
-3398.46  
-167.10 5898.90  
-1850.17  
-1171.40 2.75 33988.10 9774.59  
-3696.16  
-158.15 6268.38  
-2155.04  
-974.14 3.0 41117.20 6515.41  
-3381.03  
-148.32 6548.78  
-2413.74  
-948.98 4.0 71428.60  
-18297.80 3576.44  
-123.51 7125.21  
-2923.50  
-632.21 5.0 100397.00  
-56458.80 20611.70  
-115.75 7125.58  
-2528.06  
-313.97 6.0 124283.00  
-97234.10 43750.10  
-135.36 7393.89  
-2038.45  
-178.07 7.0 142677.00  
-131502.00 64937.90  
-142.42 7276.64  
-994.67  
-255.89 8.0 158111.00  
-164750.00 89150.00  
-165.13 7682.79  
-614.18  
-382.56 9.0 169539.00  
-187815.00 105688.00  
-170.16 7701.54 95.21  
-536.66 10.0 179168.00  
-207560.00 120407.00  
-172.05 7615.14 907.40  
-757.15 11.0 187428.00  
-224318.00 133228.00  
-170.11 7472.64 1710.47  
-885.30 12.0 195546.00  
-241540.00 147050.00  
-166.19 7281.30 2560.85  
-1135.94 13.0 202256.00  
-258699.00 164971.00  
-182.40 7906.42 2044.37  
-1182.19 14.0 207838.00  
-268927.00 173192.00  
-178.93 7770.91 2703.98  
-1224.09 15.0 213979.00  
-281611.00 184781.00  
-172.75 7552.21 3409.13  
-1276.86 16.0 217809.00  
-285839.00 187221.00  
-168.56 7458.11 3805.42  
-1317.69 17.0 223749.00  
-297214.00 196642.00  
-160.86 7141.47 4676.19  
-1362.21 18.0 226075.00  
-295937.00 193130.00  
-157.66 7127.19 4895.03  
-1291.13 19.0 230997.00  
-304670.00 201281.00  
-150.53 6907.85 5558.32  
-1353.07 20.0 238022.00  
-324930.00 227066.00  
-158.32 7284.25 5103.45  
-1464.16 22.0 243676.00  
-322706.00 217208.00  
-147.77 6978.74 5979.30  
-1239.05 24.0 251683.00  
-332524.00 227486.00  
-137.48 6744.91 6651.45  
-1261.39 26.0 256408.00  
-321812.00 204514.00  
-125.79 6394.39 7373.18  
-1135.32 28.0 264537.00  
-330729.00 215269.00  
-131.03 6864.20 6415.84  
-1014.55 30.0 273958.00  
-341208.00 225146.00  
-115.29 6196.43 7947.39  
-1073.39 35.0 292385.00  
-333153.00 204415.00  
-98.00 5956.86 7222.98  
-860.79 40.0 329247.00  
-419504.00 371883.00  
-71.42 4943.73 7633.01  
-1618.27  


Approved Contents 2.0 Table 2.4-4 (Page 7 of 10)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-68 Table 2.4-4 (Page 7 of 10)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling Time                                   Array/Class 9x9E/F (years)          A           B           C             D           E       F         G 2.0       16854.60   11084.70   -2322.04       -181.73     4769.99 -1147.12   -810.29 2.25       21630.80   11546.20   -2940.96       -172.49     5228.13 -1436.00   -839.61 2.5       27849.90   10029.20   -2985.66       -164.15     5650.51 -1736.59 -1040.92 2.75       34540.60   7548.11   -2786.62       -154.38     5990.92 -2013.50   -935.15 3.0       41307.10   4337.80   -2362.16       -146.82     6295.85 -2275.82   -884.96 4.0       70768.40 -20480.20     5197.61       -121.39     6876.47 -2797.83   -537.40 5.0       98180.80 -56583.30   21720.10       -115.24     7004.63 -2612.66   -168.15 6.0       120573.00 -94683.40   43765.30       -134.45     7390.91 -2400.88   20.85 7.0       138493.00 -128353.00   65326.00       -141.23     7368.45 -1657.87     2.12 8.0       151304.00 -154813.00   84923.70       -165.48     7997.42 -1799.73   -3.75 9.0       162835.00 -178601.00   102770.00       -169.20     8012.87 -1222.27   -178.21 10.0       173089.00 -200396.00   119704.00       -169.43     7906.04 -489.94   -481.35 11.0       180227.00 -213998.00   130552.00       -169.48     7924.61 -143.28   -537.04 12.0       188058.00 -230819.00   144797.00       -165.45     7782.15   482.35   -705.69 13.0       193490.00 -240795.00   153382.00       -163.80     7756.04   834.76   -753.66 14.0       199338.00 -255751.00   170303.00       -178.59     8424.78   16.81   -795.55 15.0       204471.00 -264530.00   177215.00       -172.61     8186.47   708.91   -873.25 16.0       209807.00 -275635.00   189071.00       -167.97     8087.71 1042.99   -936.73 17.0       214452.00 -282609.00   194830.00       -159.86     7819.12 1616.41   -906.17 18.0       217197.00 -283928.00   195786.00       -157.56     7869.81 1568.69   -890.15 19.0       221266.00 -288837.00   199363.00       -149.64     7592.40 2213.50   -965.82 20.0       225737.00 -295774.00   205279.00       -143.23     7337.40 2875.11   -876.23 22.0       234598.00 -314227.00   231133.00       -148.51     7825.76 2021.35   -879.15 24.0       242046.00 -320606.00   235951.00       -134.75     7367.58 2926.98   -913.50 26.0       247960.00 -318479.00   229552.00       -123.51     7133.33 3171.11   -783.22 28.0       261521.00 -352854.00   278305.00       -120.41     7120.21 3024.72 -1121.44 30.0       264913.00 -340198.00   263913.00       -111.92     6968.28 2888.33   -788.23 35.0       288082.00 -360268.00   293412.00       -86.40     6220.44 2894.70   -961.02 40.0       298948.00 -303570.00   215523.00       -55.72     5417.82   785.23   -415.39 Certificate of Compliance No. 1014                                            Amendment No. 12 Appendix B                                      2-68
Cooling Time (years)
Array/Class 9x9E/F A
B C
D E
F G
2.0 16854.60 11084.70  
-2322.04  
-181.73 4769.99  
-1147.12  
-810.29 2.25 21630.80 11546.20  
-2940.96  
-172.49 5228.13  
-1436.00  
-839.61 2.5 27849.90 10029.20  
-2985.66  
-164.15 5650.51  
-1736.59  
-1040.92 2.75 34540.60 7548.11  
-2786.62  
-154.38 5990.92  
-2013.50  
-935.15 3.0 41307.10 4337.80  
-2362.16  
-146.82 6295.85  
-2275.82  
-884.96 4.0 70768.40  
-20480.20 5197.61  
-121.39 6876.47  
-2797.83  
-537.40 5.0 98180.80  
-56583.30 21720.10  
-115.24 7004.63  
-2612.66  
-168.15 6.0 120573.00  
-94683.40 43765.30  
-134.45 7390.91  
-2400.88 20.85 7.0 138493.00  
-128353.00 65326.00  
-141.23 7368.45  
-1657.87 2.12 8.0 151304.00  
-154813.00 84923.70  
-165.48 7997.42  
-1799.73  
-3.75 9.0 162835.00  
-178601.00 102770.00  
-169.20 8012.87  
-1222.27  
-178.21 10.0 173089.00  
-200396.00 119704.00  
-169.43 7906.04  
-489.94  
-481.35 11.0 180227.00  
-213998.00 130552.00  
-169.48 7924.61  
-143.28  
-537.04 12.0 188058.00  
-230819.00 144797.00  
-165.45 7782.15 482.35  
-705.69 13.0 193490.00  
-240795.00 153382.00  
-163.80 7756.04 834.76  
-753.66 14.0 199338.00  
-255751.00 170303.00  
-178.59 8424.78 16.81  
-795.55 15.0 204471.00  
-264530.00 177215.00  
-172.61 8186.47 708.91  
-873.25 16.0 209807.00  
-275635.00 189071.00  
-167.97 8087.71 1042.99  
-936.73 17.0 214452.00  
-282609.00 194830.00  
-159.86 7819.12 1616.41  
-906.17 18.0 217197.00  
-283928.00 195786.00  
-157.56 7869.81 1568.69  
-890.15 19.0 221266.00  
-288837.00 199363.00  
-149.64 7592.40 2213.50  
-965.82 20.0 225737.00  
-295774.00 205279.00  
-143.23 7337.40 2875.11  
-876.23 22.0 234598.00  
-314227.00 231133.00  
-148.51 7825.76 2021.35  
-879.15 24.0 242046.00  
-320606.00 235951.00  
-134.75 7367.58 2926.98  
-913.50 26.0 247960.00  
-318479.00 229552.00  
-123.51 7133.33 3171.11  
-783.22 28.0 261521.00  
-352854.00 278305.00  
-120.41 7120.21 3024.72  
-1121.44 30.0 264913.00  
-340198.00 263913.00  
-111.92 6968.28 2888.33  
-788.23 35.0 288082.00  
-360268.00 293412.00  
-86.40 6220.44 2894.70  
-961.02 40.0 298948.00  
-303570.00 215523.00  
-55.72 5417.82 785.23  
-415.39  


Approved Contents 2.0 Table 2.4-4 (Page 8 of 10)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-69 Table 2.4-4 (Page 8 of 10)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling Time                                     Array/Class 9x9G (years)          A           B           C             D           E       F         G 2.0       18157.70   12664.10   -2736.69       -182.35     5344.31 -1383.11   -916.79 2.25       23646.70   12752.10   -3248.16       -178.95     5971.94 -1793.73   -925.78 2.5       29660.10   12309.80   -3821.64       -169.21     6473.09 -2183.65   -879.92 2.75       36525.80   10358.80   -3962.11       -162.46     6968.29 -2613.38   -863.49 3.0       44006.40   7030.85   -3698.49       -153.38     7336.54 -2971.63   -809.92 4.0       77288.30 -21207.50     4543.15       -125.70     8058.78 -3705.78   -537.87 5.0       110686.00 -69960.20   29062.30       -130.54     8442.77 -3626.36   -336.85 6.0       137786.00 -118830.00   58088.00       -136.52     8339.36 -2532.48   -201.40 7.0       160795.00 -169293.00   94340.50       -161.16     8672.27 -1671.25   -379.07 8.0       177763.00 -207034.00   122389.00       -170.18     8619.96 -400.24   -562.99 9.0       193108.00 -243101.00   150849.00       -171.94     8368.05 1156.18   -881.11 10.0       205042.00 -275555.00   181997.00       -195.35     9071.69 1098.87 -1083.51 11.0       215280.00 -300568.00   204362.00       -194.55     8934.09 2200.13 -1266.10 12.0       223585.00 -319189.00   220301.00       -191.69     8775.21 3201.84 -1325.62 13.0       230947.00 -335777.00   234994.00       -189.96     8659.97 4110.52 -1472.39 14.0       239135.00 -355478.00   253619.00       -183.93     8406.36 5194.67 -1726.13 15.0       245572.00 -374776.00   278406.00       -203.34     9278.36 4194.86 -1666.34 16.0       251881.00 -387322.00   288544.00       -193.80     8836.24 5557.89 -1689.56 17.0       257861.00 -401610.00   304798.00       -189.68     8737.81 6220.47 -1840.71 18.0       262232.00 -408488.00   311370.00       -185.11     8602.16 6925.67 -1728.75 19.0       265329.00 -406025.00   301388.00       -178.52     8347.70 7730.36 -1689.95 20.0       271234.00 -419055.00   315509.00       -171.72     8067.36 8751.47 -1705.40 22.0       283895.00 -451199.00   356261.00       -175.40     8389.72 8926.87 -1890.66 24.0       288388.00 -437401.00   323902.00       -164.80     8075.31 9968.86 -1575.02 26.0       299757.00 -459004.00   349014.00       -154.15     7793.16 11086.10 -1690.60 28.0       312233.00 -487890.00   389532.00       -156.41     8001.62 11248.70 -1695.28 30.0       317451.00 -470929.00   352843.00       -144.12     7616.90 12129.50 -1519.49 35.0       340908.00 -472938.00   320383.00       -126.33     6958.19 14189.40 -1265.87 40.0       355826.00 -406707.00   181832.00       -109.88     6567.54 13350.90   -690.33 Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      2-69
Cooling Time (years)
Array/Class 9x9G A
B C
D E
F G
2.0 18157.70 12664.10  
-2736.69  
-182.35 5344.31  
-1383.11  
-916.79 2.25 23646.70 12752.10  
-3248.16  
-178.95 5971.94  
-1793.73  
-925.78 2.5 29660.10 12309.80  
-3821.64  
-169.21 6473.09  
-2183.65  
-879.92 2.75 36525.80 10358.80  
-3962.11  
-162.46 6968.29  
-2613.38  
-863.49 3.0 44006.40 7030.85  
-3698.49  
-153.38 7336.54  
-2971.63  
-809.92 4.0 77288.30  
-21207.50 4543.15  
-125.70 8058.78  
-3705.78  
-537.87 5.0 110686.00  
-69960.20 29062.30  
-130.54 8442.77  
-3626.36  
-336.85 6.0 137786.00  
-118830.00 58088.00  
-136.52 8339.36  
-2532.48  
-201.40 7.0 160795.00  
-169293.00 94340.50  
-161.16 8672.27  
-1671.25  
-379.07 8.0 177763.00  
-207034.00 122389.00  
-170.18 8619.96  
-400.24  
-562.99 9.0 193108.00  
-243101.00 150849.00  
-171.94 8368.05 1156.18  
-881.11 10.0 205042.00  
-275555.00 181997.00  
-195.35 9071.69 1098.87  
-1083.51 11.0 215280.00  
-300568.00 204362.00  
-194.55 8934.09 2200.13  
-1266.10 12.0 223585.00  
-319189.00 220301.00  
-191.69 8775.21 3201.84  
-1325.62 13.0 230947.00  
-335777.00 234994.00  
-189.96 8659.97 4110.52  
-1472.39 14.0 239135.00  
-355478.00 253619.00  
-183.93 8406.36 5194.67  
-1726.13 15.0 245572.00  
-374776.00 278406.00  
-203.34 9278.36 4194.86  
-1666.34 16.0 251881.00  
-387322.00 288544.00  
-193.80 8836.24 5557.89  
-1689.56 17.0 257861.00  
-401610.00 304798.00  
-189.68 8737.81 6220.47  
-1840.71 18.0 262232.00  
-408488.00 311370.00  
-185.11 8602.16 6925.67  
-1728.75 19.0 265329.00  
-406025.00 301388.00  
-178.52 8347.70 7730.36  
-1689.95 20.0 271234.00  
-419055.00 315509.00  
-171.72 8067.36 8751.47  
-1705.40 22.0 283895.00  
-451199.00 356261.00  
-175.40 8389.72 8926.87  
-1890.66 24.0 288388.00  
-437401.00 323902.00  
-164.80 8075.31 9968.86  
-1575.02 26.0 299757.00  
-459004.00 349014.00  
-154.15 7793.16 11086.10  
-1690.60 28.0 312233.00  
-487890.00 389532.00  
-156.41 8001.62 11248.70  
-1695.28 30.0 317451.00  
-470929.00 352843.00  
-144.12 7616.90 12129.50  
-1519.49 35.0 340908.00  
-472938.00 320383.00  
-126.33 6958.19 14189.40  
-1265.87 40.0 355826.00  
-406707.00 181832.00  
-109.88 6567.54 13350.90  
-690.33  


Approved Contents 2.0 Table 2.4-4 (Page 9 of 10)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-70 Table 2.4-4 (Page 9 of 10)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling Time                                   Array/Class 10x10A/B/G (years)          A           B           C             D           E       F         G 2.0       16284.00   11316.60   -2373.42       -183.95     4757.49 -1129.72   -908.53 2.25       21494.10   11161.90   -2738.06       -174.87     5233.98 -1435.08 -1029.88 2.5       27378.90   10122.70   -3001.13       -163.37     5590.72 -1687.18 -1133.76 2.75       33997.50     7667.21   -2796.85       -154.59     5934.47 -1960.21 -1063.93 3.0       40669.30     4604.85   -2427.68       -146.64     6233.46 -2224.40 -1023.08 4.0       69456.60   -19048.60     4510.80       -121.07     6769.53 -2693.26   -595.32 5.0       96363.50   -53810.50   20060.80       -115.15     6852.01 -2455.28   -235.29 6.0       118075.00   -89649.00   40101.30       -135.03     7207.34 -2199.03   -31.82 7.0       135465.00 -121448.00   59891.00       -141.81     7176.22 -1464.52   -84.35 8.0       149172.00 -147759.00   77477.10       -146.29     7123.94 -720.75   -270.69 9.0       160098.00 -171854.00   96698.30       -168.49     7716.07 -861.33   -341.94 10.0       168703.00 -188210.00   108590.00       -170.65     7707.01 -369.98   -413.26 11.0       176895.00 -205123.00   122221.00       -167.56     7590.63   267.07   -597.28 12.0       183500.00 -217775.00   132403.00       -165.29     7503.92   748.16   -696.44 13.0       189527.00 -229054.00   141757.00       -162.77     7481.92 1050.96   -848.98 14.0       195892.00 -241671.00   152138.00       -155.37     7192.81 1854.09   -983.23 15.0       199561.00 -249322.00   161820.00       -172.75     7962.69   824.80   -863.19 16.0       204447.00 -258563.00   171271.00       -167.33     7839.02 1163.01   -928.77 17.0       209187.00 -266807.00   178586.00       -160.49     7588.94 1870.46   -983.28 18.0       212908.00 -270532.00   180865.00       -155.48     7487.99 2077.63   -955.84 19.0       216478.00 -274912.00   185127.00       -150.92     7417.63 2302.50   -949.30 20.0       219761.00 -276790.00   185299.00       -144.53     7207.71 2794.21   -860.04 22.0       230330.00 -297894.00   208958.00       -142.95     7317.84 2710.62 -1141.54 24.0       235204.00 -296597.00   207242.00       -136.96     7299.78 2658.68   -881.02 26.0       243035.00 -302622.00   210474.00       -120.72     6753.85 3686.66   -891.14 28.0       250446.00 -307503.00   216130.00       -107.51     6366.92 4185.55   -863.84 30.0       265199.00 -348982.00   280458.00       -107.22     6539.80 3562.03 -1192.36 35.0       273468.00 -298369.00   203934.00       -79.97     5875.23 3082.40   -627.85 40.0       292898.00 -285148.00   187876.00       -50.41     4835.07 2436.15   -509.94 Certificate of Compliance No. 1014                                            Amendment No. 12 Appendix B                                      2-70
Cooling Time (years)
Array/Class 10x10A/B/G A
B C
D E
F G
2.0 16284.00 11316.60  
-2373.42  
-183.95 4757.49  
-1129.72  
-908.53 2.25 21494.10 11161.90  
-2738.06  
-174.87 5233.98  
-1435.08  
-1029.88 2.5 27378.90 10122.70  
-3001.13  
-163.37 5590.72  
-1687.18  
-1133.76 2.75 33997.50 7667.21  
-2796.85  
-154.59 5934.47  
-1960.21  
-1063.93 3.0 40669.30 4604.85  
-2427.68  
-146.64 6233.46  
-2224.40  
-1023.08 4.0 69456.60  
-19048.60 4510.80  
-121.07 6769.53  
-2693.26  
-595.32 5.0 96363.50  
-53810.50 20060.80  
-115.15 6852.01  
-2455.28  
-235.29 6.0 118075.00  
-89649.00 40101.30  
-135.03 7207.34  
-2199.03  
-31.82 7.0 135465.00  
-121448.00 59891.00  
-141.81 7176.22  
-1464.52  
-84.35 8.0 149172.00  
-147759.00 77477.10  
-146.29 7123.94  
-720.75  
-270.69 9.0 160098.00  
-171854.00 96698.30  
-168.49 7716.07  
-861.33  
-341.94 10.0 168703.00  
-188210.00 108590.00  
-170.65 7707.01  
-369.98  
-413.26 11.0 176895.00  
-205123.00 122221.00  
-167.56 7590.63 267.07  
-597.28 12.0 183500.00  
-217775.00 132403.00  
-165.29 7503.92 748.16  
-696.44 13.0 189527.00  
-229054.00 141757.00  
-162.77 7481.92 1050.96  
-848.98 14.0 195892.00  
-241671.00 152138.00  
-155.37 7192.81 1854.09  
-983.23 15.0 199561.00  
-249322.00 161820.00  
-172.75 7962.69 824.80  
-863.19 16.0 204447.00  
-258563.00 171271.00  
-167.33 7839.02 1163.01  
-928.77 17.0 209187.00  
-266807.00 178586.00  
-160.49 7588.94 1870.46  
-983.28 18.0 212908.00  
-270532.00 180865.00  
-155.48 7487.99 2077.63  
-955.84 19.0 216478.00  
-274912.00 185127.00  
-150.92 7417.63 2302.50  
-949.30 20.0 219761.00  
-276790.00 185299.00  
-144.53 7207.71 2794.21  
-860.04 22.0 230330.00  
-297894.00 208958.00  
-142.95 7317.84 2710.62  
-1141.54 24.0 235204.00  
-296597.00 207242.00  
-136.96 7299.78 2658.68  
-881.02 26.0 243035.00  
-302622.00 210474.00  
-120.72 6753.85 3686.66  
-891.14 28.0 250446.00  
-307503.00 216130.00  
-107.51 6366.92 4185.55  
-863.84 30.0 265199.00  
-348982.00 280458.00  
-107.22 6539.80 3562.03  
-1192.36 35.0 273468.00  
-298369.00 203934.00  
-79.97 5875.23 3082.40  
-627.85 40.0 292898.00  
-285148.00 187876.00  
-50.41 4835.07 2436.15  
-509.94  


Approved Contents 2.0 Table 2.4-4 (Page 10 of 10)
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-71 Table 2.4-4 (Page 10 of 10)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)
Cooling Time                                     Array/Class 10x10C (years)          A           B           C             D           E       F         G 2.0       17325.30   11490.30     -2423.96       -183.30     5030.60 -1243.75 -1042.41 2.25       22130.00   11951.30     -2993.28       -179.73     5638.45 -1641.98 -1049.38 2.5       28141.40   10893.00     -3249.42       -171.97     6092.80 -1970.42 -1042.25 2.75       35001.90     8485.77     -3132.08       -161.49     6464.02 -2288.54 -1064.03 3.0       41817.40     5588.18     -2935.15       -152.37     6778.27 -2580.33   -960.42 4.0       72503.80   -20126.90     4676.40       -126.12     7389.26 -3161.51   -598.75 5.0       101686.00   -58844.80     22172.30       -118.88     7430.83 -2824.08   -314.90 6.0       125964.00 -100714.00     46115.40       -137.38     7670.65 -2280.40   -139.13 7.0       145279.00 -138063.00     69971.00       -145.81     7593.29 -1239.47   -240.17 8.0       160736.00 -171770.00     94922.90       -169.48     8074.18 -936.98   -413.14 9.0       173109.00 -198050.00   114195.00       -173.24     7952.04   107.22   -587.69 10.0       183348.00 -219689.00   130706.00       -174.38     7886.25   887.26   -747.19 11.0       192349.00 -239413.00   146643.00       -173.03     7738.68 1801.89   -960.79 12.0       198722.00 -251849.00   156661.00       -174.40     7779.41 2247.21 -1024.32 13.0       206317.00 -271870.00   177242.00       -191.21     8405.58 1825.60 -1138.70 14.0       212647.00 -284224.00   187282.00       -183.63     8103.28 2759.09 -1219.61 15.0       218920.00 -297923.00   200391.00       -179.50     7978.82 3335.37 -1313.57 16.0       223379.00 -304963.00   206476.00       -175.76     7922.23 3689.54 -1328.16 17.0       228676.00 -314595.00   214380.00       -168.29     7569.76 4728.35 -1384.57 18.0       233175.00 -321606.00   220636.00       -164.63     7582.84 4872.65 -1394.73 19.0       238334.00 -334048.00   236292.00       -170.69     7886.97 4618.40 -1403.78 20.0       242429.00 -340497.00   242818.00       -172.36     8094.92 4434.37 -1437.97 22.0       251428.00 -353397.00   253878.00       -156.59     7500.41 6060.21 -1412.04 24.0       257957.00 -354461.00   249954.00       -147.71     7305.10 6634.39 -1346.94 26.0       272010.00 -391459.00   299301.00       -145.25     7227.25 7258.81 -1619.05 28.0       273995.00 -368436.00   261102.00       -136.90     7071.78 7562.48 -1159.20 30.0       279666.00 -356857.00   232864.00       -125.34     6696.43 8273.08   -973.58 35.0       297242.00 -340805.00   191056.00       -108.66     6404.77 8127.91   -777.55 40.0       330405.00 -398218.00   299749.00       -84.01     5531.03 7980.06 -1232.79 Certificate of Compliance No. 1014                                              Amendment No. 12 Appendix B                                        2-71
Cooling Time (years)
Array/Class 10x10C A
B C
D E
F G
2.0 17325.30 11490.30  
-2423.96  
-183.30 5030.60  
-1243.75  
-1042.41 2.25 22130.00 11951.30  
-2993.28  
-179.73 5638.45  
-1641.98  
-1049.38 2.5 28141.40 10893.00  
-3249.42  
-171.97 6092.80  
-1970.42  
-1042.25 2.75 35001.90 8485.77  
-3132.08  
-161.49 6464.02  
-2288.54  
-1064.03 3.0 41817.40 5588.18  
-2935.15  
-152.37 6778.27  
-2580.33  
-960.42 4.0 72503.80  
-20126.90 4676.40  
-126.12 7389.26  
-3161.51  
-598.75 5.0 101686.00  
-58844.80 22172.30  
-118.88 7430.83  
-2824.08  
-314.90 6.0 125964.00  
-100714.00 46115.40  
-137.38 7670.65  
-2280.40  
-139.13 7.0 145279.00  
-138063.00 69971.00  
-145.81 7593.29  
-1239.47  
-240.17 8.0 160736.00  
-171770.00 94922.90  
-169.48 8074.18  
-936.98  
-413.14 9.0 173109.00  
-198050.00 114195.00  
-173.24 7952.04 107.22  
-587.69 10.0 183348.00  
-219689.00 130706.00  
-174.38 7886.25 887.26  
-747.19 11.0 192349.00  
-239413.00 146643.00  
-173.03 7738.68 1801.89  
-960.79 12.0 198722.00  
-251849.00 156661.00  
-174.40 7779.41 2247.21  
-1024.32 13.0 206317.00  
-271870.00 177242.00  
-191.21 8405.58 1825.60  
-1138.70 14.0 212647.00  
-284224.00 187282.00  
-183.63 8103.28 2759.09  
-1219.61 15.0 218920.00  
-297923.00 200391.00  
-179.50 7978.82 3335.37  
-1313.57 16.0 223379.00  
-304963.00 206476.00  
-175.76 7922.23 3689.54  
-1328.16 17.0 228676.00  
-314595.00 214380.00  
-168.29 7569.76 4728.35  
-1384.57 18.0 233175.00  
-321606.00 220636.00  
-164.63 7582.84 4872.65  
-1394.73 19.0 238334.00  
-334048.00 236292.00  
-170.69 7886.97 4618.40  
-1403.78 20.0 242429.00  
-340497.00 242818.00  
-172.36 8094.92 4434.37  
-1437.97 22.0 251428.00  
-353397.00 253878.00  
-156.59 7500.41 6060.21  
-1412.04 24.0 257957.00  
-354461.00 249954.00  
-147.71 7305.10 6634.39  
-1346.94 26.0 272010.00  
-391459.00 299301.00  
-145.25 7227.25 7258.81  
-1619.05 28.0 273995.00  
-368436.00 261102.00  
-136.90 7071.78 7562.48  
-1159.20 30.0 279666.00  
-356857.00 232864.00  
-125.34 6696.43 8273.08  
-973.58 35.0 297242.00  
-340805.00 191056.00  
-108.66 6404.77 8127.91  
-777.55 40.0 330405.00  
-398218.00 299749.00  
-84.01 5531.03 7980.06  
-1232.79  


Approved Contents 2.0 1       2 0.5*     0.5*
Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-72 1
3       4     5       6         7         8 0.5*     0.5   1.2     1.2     0.5       0.5*
2 0.5*
9       10     11     12       13       14       15       16 0.5*   0.5     1.2   0.4     0.4     1.2       0.5     0.5*
0.5*
17     18     19     20       21       22       23       24 0.5     1.2     0.4   0.4     0.4     0.4       1.2     0.5 25         26     27     28     29       30       31       32       33   34 0.5*       1.2     0.4     0.4   0.4     0.4     0.4       0.4     1.2   0.5*
3 4
35         36     37     38     39       40       41       42       43   44 0.5*       1.2     0.4     0.4   0.4     0.4     0.4       0.4     1.2   0.5*
5 6
45     46     47     48       49       50       51       52 0.5     1.2     0.4   0.4     0.4     0.4       1.2     0.5 53     54     55     56       57       58       59       60 0.5*   0.5     1.2   0.4     0.4     1.2       0.5     0.5*
7 8
61     62     63       64       65       66 0.5*     0.5   1.2     1.2     0.5       0.5*
0.5*
Cell ID                               67       68 Heat Load                             0.5*     0.5*
0.5 1.2 1.2 0.5 0.5*
(kW)
9 10 11 12 13 14 15 16 0.5*
* When DAMAGED FUEL or FUEL DEBRIS is stored in this location (in a DFC), the allowable heat load of the cell is limited to 0.35 kW Figure 2.4-1 Per Cell Allowable Heat Loads (kW) - MPC-68M Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                  2-72
0.5 1.2 0.4 0.4 1.2 0.5 0.5*
17 18 19 20 21 22 23 24 0.5 1.2 0.4 0.4 0.4 0.4 1.2 0.5 25 26 27 28 29 30 31 32 33 34 0.5*
1.2 0.4 0.4 0.4 0.4 0.4 0.4 1.2 0.5*
35 36 37 38 39 40 41 42 43 44 0.5*
1.2 0.4 0.4 0.4 0.4 0.4 0.4 1.2 0.5*
45 46 47 48 49 50 51 52 0.5 1.2 0.4 0.4 0.4 0.4 1.2 0.5 53 54 55 56 57 58 59 60 0.5*
0.5 1.2 0.4 0.4 1.2 0.5 0.5*
61 62 63 64 65 66 0.5*
0.5 1.2 1.2 0.5 0.5*
Cell ID 67 68 Heat Load (kW) 0.5*
0.5*
* When DAMAGED FUEL or FUEL DEBRIS is stored in this location (in a DFC), the allowable heat load of the cell is limited to 0.35 kW Figure 2.4-1 Per Cell Allowable Heat Loads (kW) - MPC-68M  


Design Features 3.0 3.0   DESIGN FEATURES 3.1   Site 3.1.1   Site Location The HI-STORM 100 Cask System is authorized for general use by 10 CFR Part 50 license holders at various site locations under the provisions of 10 CFR 72, Subpart K.
Design Features 3.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-1 3.0 DESIGN FEATURES 3.1 Site 3.1.1 Site Location The HI-STORM 100 Cask System is authorized for general use by 10 CFR Part 50 license holders at various site locations under the provisions of 10 CFR 72, Subpart K.
3.2   Design Features Important for Criticality Control 3.2.1   MPC-24
3.2 Design Features Important for Criticality Control 3.2.1 MPC-24
: 1.     Flux trap size: 1.09 in.
: 1.
: 2.     10B loading in the neutron absorbers: 0.0267 g/cm2 (Boral) and 0.0223 g/cm2 (METAMIC) 3.2.2   MPC-68 and MPC-68FF
Flux trap size: 1.09 in.
: 1.     Fuel cell pitch: 6.43 in.
: 2.
: 2.     10B loading in the neutron absorbers: 0.0372 g/cm2 (Boral) and 0.0310 g/cm2 (METAMIC) 3.2.3   MPC-68F
10B loading in the neutron absorbers: 0.0267 g/cm2 (Boral) and 0.0223 g/cm2 (METAMIC) 3.2.2 MPC-68 and MPC-68FF
: 1. Fuel cell pitch: 6.43 in.
: 1.
: 2. 10B loading in the Boral neutron absorbers: 0.01 g/cm2 3.2.4   MPC-24E and MPC-24EF
Fuel cell pitch: 6.43 in.
: 1. Flux trap size:
: 2.
: i. Cells 3, 6, 19, and 22: 0.776 inch ii. All Other Cells: 1.076 inches
10B loading in the neutron absorbers: 0.0372 g/cm2 (Boral) and 0.0310 g/cm2 (METAMIC) 3.2.3 MPC-68F
: 2. 10B loading in the neutron absorbers: 0.0372 g/cm2 (Boral) and 0.0310 g/cm2 (METAMIC) 3.2.5   MPC-32 and MPC-32F
: 1.
: 1. Fuel cell pitch: 9.158 inches
Fuel cell pitch: 6.43 in.
: 2. 10B loading in the neutron absorbers: 0.0372 g/cm2 (Boral) and 0.0310 g/cm2 (METAMIC)
: 2.
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                      3-1
10B loading in the Boral neutron absorbers: 0.01 g/cm2 3.2.4 MPC-24E and MPC-24EF
: 1.
Flux trap size:
: i. Cells 3, 6, 19, and 22: 0.776 inch ii. All Other Cells: 1.076 inches
: 2.
10B loading in the neutron absorbers: 0.0372 g/cm2 (Boral) and 0.0310 g/cm2 (METAMIC) 3.2.5 MPC-32 and MPC-32F
: 1.
Fuel cell pitch: 9.158 inches
: 2.
10B loading in the neutron absorbers: 0.0372 g/cm2 (Boral) and 0.0310 g/cm2 (METAMIC)


Design Features 3.0 DESIGN FEATURES (continued) 3.2   Design features Important for Criticality Control (contd) 3.2.6   MPC-68M
Design Features 3.0 DESIGN FEATURES (continued)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-2 3.2 Design features Important for Criticality Control (contd) 3.2.6 MPC-68M
: 1. Basket Cell wall thickness 0.4 in. (nom.)
: 1. Basket Cell wall thickness 0.4 in. (nom.)
: 2. B4C content in METAMIC-HT shall be 10 wt. %
: 2. B4C content in METAMIC-HT shall be 10 wt. %
3.2.7   Fuel spacers shall be sized to ensure that the active fuel region of intact or undamaged fuel assemblies remains within the neutron poison region of the MPC basket with water in the MPC.
3.2.7 Fuel spacers shall be sized to ensure that the active fuel region of intact or undamaged fuel assemblies remains within the neutron poison region of the MPC basket with water in the MPC.
3.2.8   The B4C content in METAMIC shall be 33.0 wt.%.
3.2.8 The B4C content in METAMIC shall be 33.0 wt.%.
3.2.9   Neutron Absorber Tests Boral and Metamic Classic Section 9.1.5.3 of the HI-STORM 100 FSAR is hereby incorporated by reference into the HI-STORM 100 CoC. For each MPC model specified in Sections 3.2.1 through 3.2.5 above, the neutron absorber shall meet the minimum requirements for 10B areal density or B4C content, as applicable.
3.2.9 Neutron Absorber Tests Boral and Metamic Classic Section 9.1.5.3 of the HI-STORM 100 FSAR is hereby incorporated by reference into the HI-STORM 100 CoC. For each MPC model specified in Sections 3.2.1 through 3.2.5 above, the neutron absorber shall meet the minimum requirements for 10B areal density or B4C content, as applicable.
Metamic-HT (Section 3.2.6 above)
Metamic-HT (Section 3.2.6 above)
: 1. The weight percentage of the boron carbide must be confirmed to be greater than or equal to 10% in each lot of Al/B4C powder.
: 1. The weight percentage of the boron carbide must be confirmed to be greater than or equal to 10% in each lot of Al/B4C powder.
Line 820: Line 3,091:
: 3. If the B-10 areal density criterion in the tested panels fails to meet the specific minimum, then the manufacturer has the option to reject the entire lot or to test a statistically significant number of panels and perform statistical analysis for acceptance.
: 3. If the B-10 areal density criterion in the tested panels fails to meet the specific minimum, then the manufacturer has the option to reject the entire lot or to test a statistically significant number of panels and perform statistical analysis for acceptance.
: 4. All test procedures used in demonstrating compliance with the above requirements shall conform to the cask designers QA program which has been approved by the USNRC under docket number 71-0784.
: 4. All test procedures used in demonstrating compliance with the above requirements shall conform to the cask designers QA program which has been approved by the USNRC under docket number 71-0784.
3.3   Codes and Standards The American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code), 1995 Edition with Addenda through 1997, is the governing Code for the HI-STORM 100 System MPCs, OVERPACKs, and TRANSFER CASKs, as clarified in Specification 3.3.1 below, except for Code Sections V and IX. The latest effective editions of ASME Code Sections V and IX, including addenda, may be used for activities governed by those sections, provided a written reconciliation of the later edition against the 1995 Edition, including addenda, is performed by the certificate holder. American Concrete Institute (ACI) 349-85 is the governing Code for plain concrete as clarified in Appendix 1.D of the Final Safety Analysis Report for the HI-STORM 100 Cask System.
3.3 Codes and Standards The American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code), 1995 Edition with Addenda through 1997, is the governing Code for the HI-STORM 100 System MPCs, OVERPACKs, and TRANSFER CASKs, as clarified in Specification 3.3.1 below, except for Code Sections V and IX. The latest effective editions of ASME Code Sections V and IX, including addenda, may be used for activities governed by those sections, provided a written reconciliation of the later edition against the 1995 Edition, including addenda, is performed by the certificate holder. American Concrete Institute (ACI) 349-85 is the governing Code for plain concrete as clarified in Appendix 1.D of the Final Safety Analysis Report for the HI-STORM 100 Cask System.  
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    3-2


Design Features 3.0 DESIGN FEATURES (continued) 3.3.1   Alternatives to Codes, Standards, and Criteria Table 3-1 lists approved alternatives to the ASME Code for the design of the MPCs, OVERPACKs, and TRANSFER CASKs of the HI-STORM 100 Cask System.
Design Features 3.0 DESIGN FEATURES (continued)
3.3.2   Construction/Fabrication Alternatives to Codes, Standards, and Criteria Proposed alternatives to the ASME Code, Sections II and III, 1995 Edition with Addenda through 1997 including modifications to the alternatives allowed by Specification 3.3.1 may be used on a case-specific basis when authorized by the Director of the Office of Nuclear Material Safety and Safeguards or designee. The request for such alternative should demonstrate that:
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-3 3.3.1 Alternatives to Codes, Standards, and Criteria Table 3-1 lists approved alternatives to the ASME Code for the design of the MPCs, OVERPACKs, and TRANSFER CASKs of the HI-STORM 100 Cask System.
: 1. The proposed alternatives would provide an acceptable level of quality and safety, or
3.3.2 Construction/Fabrication Alternatives to Codes, Standards, and Criteria Proposed alternatives to the ASME Code, Sections II and III, 1995 Edition with Addenda through 1997 including modifications to the alternatives allowed by Specification 3.3.1 may be used on a case-specific basis when authorized by the Director of the Office of Nuclear Material Safety and Safeguards or designee. The request for such alternative should demonstrate that:
: 2. Compliance with the specified requirements of the ASME Code, Section III, 1995 Edition with Addenda through 1997, would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.
: 1.
The proposed alternatives would provide an acceptable level of quality and safety, or
: 2.
Compliance with the specified requirements of the ASME Code, Section III, 1995 Edition with Addenda through 1997, would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.
Requests for alternatives shall be submitted in accordance with 10 CFR 72.4.
Requests for alternatives shall be submitted in accordance with 10 CFR 72.4.
(continued)
(continued)  
Certificate of Compliance No. 1014                                      Amendment No. 12 Appendix B                                    3-3


Design Features 3.0 DESIGN FEATURES (continued)
Design Features 3.0 DESIGN FEATURES (continued)
Table 3-1 (page 1 of 9)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-4 Table 3-1 (page 1 of 9)
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component       Reference             Code           Alternative, Justification & Compensatory ASME Code        Requirement                          Measures Section/Article MPC, MPC       Subsection     General             Because       the   MPC,     OVERPACK,       and basket        NCA            Requirements.        TRANSFER CASK are not ASME Code stamped assembly,                      Requires            vessels, none of the specifications, reports, HI-STORM                      preparation of a    certificates, or other general requirements OVERPACK                      Design              specified by NCA are required. In lieu of a Design steel                          Specification,      Specification and Design Report, the HI-STORM structure,                    Design Report,      FSAR includes the design criteria, service and HI-                        Overpressure        conditions, and load combinations for the design TRAC                          Protection Report,  and operation of the HI-STORM 100 System as TRANSFER                      Certification of    well as the results of the stress analyses to CASK steel                    Construction        demonstrate that applicable Code stress limits structure                      Report, Data        are met. Additionally, the fabricator is not Report, and other    required to have an ASME-certified QA program.
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC, MPC basket
administrative      All important-to-safety activities are governed by controls for an      the NRC-approved Holtec QA program.
: assembly, HI-STORM OVERPACK steel structure, and HI-TRAC TRANSFER CASK steel structure Subsection NCA General Requirements.
ASME Code stamped vessel.      Because the cask components are not certified to the Code, the terms Certificate Holder and Inspector are not germane to the manufacturing of NRC-certified cask components. To eliminate ambiguity, the responsibilities assigned to the Certificate Holder in the various articles of Subsections NB, NG, and NF of the Code, as applicable, shall be interpreted to apply to the NRC Certificate of Compliance (CoC) holder (and by extension, to the component fabricator) if the requirement must be fulfilled. The Code term Inspector means the QA/QC personnel of the CoC holder and its vendors assigned to oversee and inspect the manufacturing process.
Requires preparation of a Design Specification, Design Report, Overpressure Protection Report, Certification of Construction Report, Data Report, and other administrative controls for an ASME Code stamped vessel.
MPC           NB-1100         Statement of         MPC enclosure vessel is designed and will be requirements for    fabricated in accordance with ASME Code, Code stamping of    Section III, Subsection NB to the maximum components.          practical extent, but Code stamping is not required.
Because the
Certificate of Compliance No. 1014                                                Amendment No. 12 Appendix B                                      3-4
: MPC, OVERPACK, and TRANSFER CASK are not ASME Code stamped vessels, none of the specifications, reports, certificates, or other general requirements specified by NCA are required. In lieu of a Design Specification and Design Report, the HI-STORM FSAR includes the design criteria, service conditions, and load combinations for the design and operation of the HI-STORM 100 System as well as the results of the stress analyses to demonstrate that applicable Code stress limits are met. Additionally, the fabricator is not required to have an ASME-certified QA program.
All important-to-safety activities are governed by the NRC-approved Holtec QA program.
Because the cask components are not certified to the Code, the terms Certificate Holder and Inspector are not germane to the manufacturing of NRC-certified cask components. To eliminate ambiguity, the responsibilities assigned to the Certificate Holder in the various articles of Subsections NB, NG, and NF of the Code, as applicable, shall be interpreted to apply to the NRC Certificate of Compliance (CoC) holder (and by extension, to the component fabricator) if the requirement must be fulfilled. The Code term Inspector means the QA/QC personnel of the CoC holder and its vendors assigned to oversee and inspect the manufacturing process.
MPC NB-1100 Statement of requirements for Code stamping of components.
MPC enclosure vessel is designed and will be fabricated in accordance with ASME Code, Section III, Subsection NB to the maximum practical extent, but Code stamping is not required.  


Design Features 3.0 DESIGN FEATURES (continued)
Design Features 3.0 DESIGN FEATURES (continued)
Table 3-1 (page 2 of 9)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-5 Table 3-1 (page 2 of 9)
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component         Reference             Code             Alternative, Justification & Compensatory ASME Code          Requirement                              Measures Section/Article MPC basket       NB-1130         NB-1132.2(d)         The MPC basket supports (nonpressure-supports                        requires that the     retaining structural attachments)and lift lugs and lift lugs                    first connecting     (nonstructural attachments (relative to the weld of a             function of lifting a loaded MPC) that are used nonpressure-         exclusively for lifting an empty MPC) are welded retaining structural to the inside of the pressure-retaining MPC attachment to a       shell, but are not designed in accordance with component shall       Subsection NB. The basket supports and be considered part   associated attachment welds are designed to of the component     satisfy the stress limits of Subsection NG and unless the weld is   the lift lugs and associated attachment welds more than 2t from     are designed to satisfy the stress limits of the pressure-         Subsection NF, as a minimum. These retaining portion of attachments and their welds are shown by the component,       analysis to meet the respective stress limits for where t is the       their service conditions. Likewise, non-structural nominal thickness     items, such as shield plugs, spacers, etc. if of the pressure-     used, can be attached to pressure-retaining retaining material. parts in the same manner.
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC basket supports and lift lugs NB-1130 NB-1132.2(d) requires that the first connecting weld of a nonpressure-retaining structural attachment to a component shall be considered part of the component unless the weld is more than 2t from the pressure-retaining portion of the component, where t is the nominal thickness of the pressure-retaining material.
NB-1132.2(e) requires that the first connecting weld of a welded nonstructural attachment to a component shall conform to NB-4430 if the connecting weld is within 2t from the pressure-retaining portion of the component.
NB-1132.2(e) requires that the first connecting weld of a welded nonstructural attachment to a component shall conform to NB-4430 if the connecting weld is within 2t from the pressure-retaining portion of the component.
MPC             NB-2000         Requires materials   Materials will be supplied by Holtec-approved to be supplied by    suppliers with Certified Material Test Reports ASME-approved        (CMTRs) in accordance with NB-2000 material supplier. requirements.
The MPC basket supports (nonpressure-retaining structural attachments)and lift lugs (nonstructural attachments (relative to the function of lifting a loaded MPC) that are used exclusively for lifting an empty MPC) are welded to the inside of the pressure-retaining MPC shell, but are not designed in accordance with Subsection NB. The basket supports and associated attachment welds are designed to satisfy the stress limits of Subsection NG and the lift lugs and associated attachment welds are designed to satisfy the stress limits of Subsection NF, as a minimum. These attachments and their welds are shown by analysis to meet the respective stress limits for their service conditions. Likewise, non-structural items, such as shield plugs, spacers, etc. if used, can be attached to pressure-retaining parts in the same manner.
MPC             NB-2121         Provides permitted   Certain duplex stainless steels are not included material              in Section II, Part D, Tables 2A and 2B. UNS specification for    S31803 duplex stainless steel alloy is evaluated pressure-retaining    in the HI-STORM 100 FSAR and meets the material, which      required design criteria for use in the HI-STORM must conform to      100 system per ASME Code Case N-635-1.
MPC NB-2000 Requires materials to be supplied by ASME-approved material supplier.
Section II, Part D, Tables 2A and 2B Certificate of Compliance No. 1014                                                    Amendment No. 12 Appendix B                                          3-5
Materials will be supplied by Holtec-approved suppliers with Certified Material Test Reports (CMTRs) in accordance with NB-2000 requirements.
MPC NB-2121 Provides permitted material specification for pressure-retaining material, which must conform to Section II, Part D, Tables 2A and 2B Certain duplex stainless steels are not included in Section II, Part D, Tables 2A and 2B. UNS S31803 duplex stainless steel alloy is evaluated in the HI-STORM 100 FSAR and meets the required design criteria for use in the HI-STORM 100 system per ASME Code Case N-635-1.  


Design Features 3.0 DESIGN FEATURES (continued)
Design Features 3.0 DESIGN FEATURES (continued)
Table 3-1 (page 3 of 9)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-6 Table 3-1 (page 3 of 9)
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component       Reference           Code           Alternative, Justification & Compensatory ASME Code        Requirement                            Measures Section/Article MPC, MPC       NB-3100         Provides             These requirements are not applicable. The HI-basket        NG-3100        requirements for    STORM FSAR, serving as the Design assembly,      NF-3100        determining          Specification, establishes the service conditions HI-STORM                      design loading      and load combinations for the storage system.
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC, MPC basket
OVERPACK                      conditions, such and HI-                        as pressure, TRAC                          temperature, and TRANSFER                      mechanical loads.
: assembly, HI-STORM OVERPACK and HI-TRAC TRANSFER CASK NB-3100 NG-3100 NF-3100 Provides requirements for determining design loading conditions, such as pressure, temperature, and mechanical loads.
CASK MPC           NB-3350         NB-3352.3           Due     to     MPC       basket-to-shell   interface requires, for        requirements, the MPC shell-to-baseplate weld Category C joints,  joint design (designated Category C) does not that the minimum    include a reinforcing fillet weld or a bevel in the dimensions of the    MPC baseplate, which makes it different than any welds and throat    of the representative configurations depicted in thickness shall be  Figure NB-4243-1. The transverse thickness of as shown in Figure  this weld is equal to the thickness of the adjoining NB-4243-1.          shell (1/2 inch). The weld is designed as a full penetration weld that receives VT and RT or UT, as well as final surface PT examinations.
These requirements are not applicable. The HI-STORM FSAR, serving as the Design Specification, establishes the service conditions and load combinations for the storage system.
MPC NB-3350 NB-3352.3 requires, for Category C joints, that the minimum dimensions of the welds and throat thickness shall be as shown in Figure NB-4243-1.
Due to MPC basket-to-shell interface requirements, the MPC shell-to-baseplate weld joint design (designated Category C) does not include a reinforcing fillet weld or a bevel in the MPC baseplate, which makes it different than any of the representative configurations depicted in Figure NB-4243-1. The transverse thickness of this weld is equal to the thickness of the adjoining shell (1/2 inch). The weld is designed as a full penetration weld that receives VT and RT or UT, as well as final surface PT examinations.
Because the MPC shell design thickness is considerably larger than the minimum thickness required by the Code, a reinforcing fillet weld that would intrude into the MPC cavity space is not included. Not including this fillet weld provides for a higher quality radiographic examination of the full penetration weld.
Because the MPC shell design thickness is considerably larger than the minimum thickness required by the Code, a reinforcing fillet weld that would intrude into the MPC cavity space is not included. Not including this fillet weld provides for a higher quality radiographic examination of the full penetration weld.
From the standpoint of stress analysis, the fillet weld serves to reduce the local bending stress (secondary stress) produced by the gross structural discontinuity defined by the flat plate/shell junction. In the MPC design, the shell and baseplate thicknesses are well beyond that required to meet their respective membrane stress intensity limits.
From the standpoint of stress analysis, the fillet weld serves to reduce the local bending stress (secondary stress) produced by the gross structural discontinuity defined by the flat plate/shell junction. In the MPC design, the shell and baseplate thicknesses are well beyond that required to meet their respective membrane stress intensity limits.  
Certificate of Compliance No. 1014                                                Amendment No. 12 Appendix B                                      3-6


Design Features 3.0 DESIGN FEATURES (continued)
Design Features 3.0 DESIGN FEATURES (continued)
Table 3-1 (page 4 of 9)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-7 Table 3-1 (page 4 of 9)
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component       Reference             Code             Alternative, Justification & Compensatory ASME Code          Requirement                            Measures Section/Article MPC, MPC       NB-4120         NB-4121.2, NG-       In-shop operations of short duration that apply Basket        NG-4120        4121.2, and NF-      heat to a component, such as plasma cutting of Assembly,      NF-4120        4121.2 provide        plate stock, welding, machining, coating, and HI-STORM                      requirements for      pouring of lead are not, unless explicitly stated by OVERPACK                      repetition of tensile the Code, defined as heat treatment operations.
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC, MPC Basket
steel                          or impact tests for structure,                    material subjected    For the steel parts in the HI-STORM 100 and HI-                        to heat treatment    System components, the duration for which a TRAC                          during fabrication    part exceeds the off-normal temperature limit TRANSFER                      or installation.      defined in Chapter 2 of the FSAR shall be CASK steel                                          limited to 24 hours in a particular manufacturing structure                                            process (such as the HI-TRAC lead pouring process).
: Assembly, HI-STORM OVERPACK steel structure, and HI-TRAC TRANSFER CASK steel structure NB-4120 NG-4120 NF-4120 NB-4121.2, NG-4121.2, and NF-4121.2 provide requirements for repetition of tensile or impact tests for material subjected to heat treatment during fabrication or installation.
MPC, MPC       NB-4220         Requires certain     The cylindricity measurements on the rolled basket        NF-4220        forming tolerances    shells are not specifically recorded in the shop assembly,                      to be met for        travelers, as would be the case for a Code-HI-STORM                      cylindrical, conical, stamped pressure vessel. Rather, the OVERPACK                      or spherical shells  requirements on inter-component clearances steel                          of a vessel.          (such as the MPC-to-TRANSFER CASK) are structure,                                          guaranteed through fixture-controlled and HI-                                              manufacturing. The fabrication specification TRAC                                                and shop procedures ensure that all TRANSFER                                            dimensional design objectives, including inter-CASK steel                                          component annular clearances are satisfied.
In-shop operations of short duration that apply heat to a component, such as plasma cutting of plate stock, welding, machining, coating, and pouring of lead are not, unless explicitly stated by the Code, defined as heat treatment operations.
structure                                            The dimensions required to be met in fabrication are chosen to meet the functional requirements of the dry storage components. Thus, although the post-forming Code cylindricity requirements are not evaluated for compliance directly, they are indirectly satisfied (actually exceeded) in the final manufactured components.
For the steel parts in the HI-STORM 100 System components, the duration for which a part exceeds the off-normal temperature limit defined in Chapter 2 of the FSAR shall be limited to 24 hours in a particular manufacturing process (such as the HI-TRAC lead pouring process).
MPC Lid       NB-4243         Full penetration     MPC lid and closure ring are not full penetration and Closure                    welds required for    welds. They are welded independently to Ring Welds                    Category C Joints    provide a redundant seal. Additionally, a weld (flat head to main    efficiency factor of 0.45 has been applied to the shell per NB-        analyses of these welds.
MPC, MPC basket
3352.3).
: assembly, HI-STORM OVERPACK steel structure, and HI-TRAC TRANSFER CASK steel structure NB-4220 NF-4220 Requires certain forming tolerances to be met for cylindrical, conical, or spherical shells of a vessel.
Certificate of Compliance No. 1014                                                  Amendment No. 12 Appendix B                                        3-7
The cylindricity measurements on the rolled shells are not specifically recorded in the shop travelers, as would be the case for a Code-stamped pressure vessel. Rather, the requirements on inter-component clearances (such as the MPC-to-TRANSFER CASK) are guaranteed through fixture-controlled manufacturing. The fabrication specification and shop procedures ensure that all dimensional design objectives, including inter-component annular clearances are satisfied.
The dimensions required to be met in fabrication are chosen to meet the functional requirements of the dry storage components. Thus, although the post-forming Code cylindricity requirements are not evaluated for compliance directly, they are indirectly satisfied (actually exceeded) in the final manufactured components.
MPC Lid and Closure Ring Welds NB-4243 Full penetration welds required for Category C Joints (flat head to main shell per NB-3352.3).
MPC lid and closure ring are not full penetration welds. They are welded independently to provide a redundant seal. Additionally, a weld efficiency factor of 0.45 has been applied to the analyses of these welds.  


Design Features 3.0 DESIGN FEATURES (continued)
Design Features 3.0 DESIGN FEATURES (continued)
Table 3-1 (page 5 of 9)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-8 Table 3-1 (page 5 of 9)
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component       Reference             Code           Alternative, Justification & Compensatory ASME Code        Requirement                            Measures Section/Article MPC Lid to     NB-5230         Radiographic (RT)   Only UT or multi-layer liquid penetrant (PT)
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC Lid to Shell Weld NB-5230 Radiographic (RT) or ultrasonic (UT) examination required Only UT or multi-layer liquid penetrant (PT) examination is permitted. If PT alone is used, at a minimum, it will include the root and final weld layers and each approximately 3/8 inch of weld depth.
Shell Weld                    or ultrasonic (UT)  examination is permitted. If PT alone is used, at examination          a minimum, it will include the root and final weld required            layers and each approximately 3/8 inch of weld depth.
MPC Closure Ring, Vent and Drain Cover Plate Welds NB-5230 Radiographic (RT) or ultrasonic (UT) examination required Root (if more than one weld pass is required) and final liquid penetrant examination to be performed in accordance with NB-5245. The closure ring provides independent redundant closure for vent and drain cover plates.
MPC           NB-5230         Radiographic (RT)   Root (if more than one weld pass is required)
MPC Enclosure Vessel and Lid NB-6111 All completed pressure retaining systems shall be pressure tested.
Closure                        or ultrasonic (UT)  and final liquid penetrant examination to be Ring, Vent                    examination          performed in accordance with NB-5245. The and Drain                      required            closure ring provides independent redundant Cover Plate                                        closure for vent and drain cover plates.
The MPC enclosure vessel is seal welded in the field following fuel assembly loading. The MPC enclosure vessel shall then be pressure tested as defined in Chapter 9. Accessibility for leakage inspections precludes a Code compliant pressure test. Since the shell welds of the MPC cannot be checked for leakage during this pressure test, the shop leakage test to 10-7 ref-cc/sec provides reasonable assurance as to its leak tightness. All MPC enclosure vessel welds (except closure ring and vent/drain cover plate) are inspected by volumetric examination, except the MPC lid-to-shell weld shall be verified by volumetric or multi-layer PT examination. If PT alone is used, at a minimum, it must include the root and final layers and each approximately 3/8 inch of weld depth. For either UT or PT, the maximum undetectable flaw size must be demonstrated to be less than the critical flaw size. The critical flaw size must be determined in accordance with ASME Section XI methods.
Welds MPC           NB-6111         All completed       The MPC enclosure vessel is seal welded in the Enclosure                      pressure retaining  field following fuel assembly loading. The MPC Vessel and                    systems shall be    enclosure vessel shall then be pressure tested Lid                            pressure tested. as defined in Chapter 9. Accessibility for leakage inspections precludes a Code compliant pressure test. Since the shell welds of the MPC cannot be checked for leakage during this pressure test, the shop leakage test to 10-7 ref-cc/sec provides reasonable assurance as to its leak tightness. All MPC enclosure vessel welds (except closure ring and vent/drain cover plate) are inspected by volumetric examination, except the MPC lid-to-shell weld shall be verified by volumetric or multi-layer PT examination. If PT alone is used, at a minimum, it must include the root and final layers and each approximately 3/8 inch of weld depth. For either UT or PT, the maximum undetectable flaw size must be demonstrated to be less than the critical flaw size. The critical flaw size must be determined in accordance with ASME Section XI methods.
The critical flaw size shall not cause the primary stress limits of NB-3000 to be exceeded.
The critical flaw size shall not cause the primary stress limits of NB-3000 to be exceeded.
The inspection results, including relevant findings (indications), shall be made a permanent part of the users records by video, photographic, or other means which provide an equivalent retrievable record of weld integrity.
The inspection results, including relevant findings (indications), shall be made a permanent part of the users records by video, photographic, or other means which provide an equivalent retrievable record of weld integrity.
The video or photographic records should be taken during the final interpretation period described in ASME Section V, Article 6, T-676.
The video or photographic records should be taken during the final interpretation period described in ASME Section V, Article 6, T-676.
The vent/drain cover plate and the closure ring welds are confirmed by liquid penetrant examination. The inspection of the weld must be performed by qualified personnel and shall meet the acceptance requirements of ASME Code Section III, NB-5350 for PT or NB-5332 for UT.
The vent/drain cover plate and the closure ring welds are confirmed by liquid penetrant examination. The inspection of the weld must be performed by qualified personnel and shall meet the acceptance requirements of ASME Code Section III, NB-5350 for PT or NB-5332 for UT.  
Certificate of Compliance No. 1014                                                Amendment No. 12 Appendix B                                      3-8


Design Features 3.0 DESIGN FEATURES (continued)
Design Features 3.0 DESIGN FEATURES (continued)
Table 3-1 (page 6 of 9)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-9 Table 3-1 (page 6 of 9)
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component       Reference           Code           Alternative, Justification & Compensatory ASME Code        Requirement                          Measures Section/Article MPC           NB-7000         Vessels are         No overpressure protection is provided. The Enclosure                      required to have    function of the MPC enclosure vessel is to Vessel                        overpressure        contain the radioactive contents under normal, protection          off-normal, and accident conditions. The MPC vessel is designed to withstand maximum internal pressure considering 100% fuel rod failure and maximum accident temperatures.
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC Enclosure Vessel NB-7000 Vessels are required to have overpressure protection No overpressure protection is provided. The function of the MPC enclosure vessel is to contain the radioactive contents under normal, off-normal, and accident conditions. The MPC vessel is designed to withstand maximum internal pressure considering 100% fuel rod failure and maximum accident temperatures.
MPC           NB-8000         States               The HI-STORM100 System is to be marked and Enclosure                      requirements for    identified in accordance with 10CFR71 and Vessel                        nameplates,          10CFR72 requirements. Code stamping is not stamping and        required. QA data package to be in accordance reports per NCA-    with Holtec approved QA program.
MPC Enclosure Vessel NB-8000 States requirements for nameplates, stamping and reports per NCA-8000.
8000.
The HI-STORM100 System is to be marked and identified in accordance with 10CFR71 and 10CFR72 requirements. Code stamping is not required. QA data package to be in accordance with Holtec approved QA program.
MPC Basket     NG-2000         Requires materials   Materials will be supplied by Holtec-approved Assembly                      to be supplied by    supplier with CMTRs in accordance with ASME-approved        NG-2000 requirements.
MPC Basket Assembly NG-2000 Requires materials to be supplied by ASME-approved material supplier.
material supplier.
Materials will be supplied by Holtec-approved supplier with CMTRs in accordance with NG-2000 requirements.  
Certificate of Compliance No. 1014                                              Amendment No. 12 Appendix B                                      3-9


Design Features 3.0 DESIGN FEATURES (continued)
Design Features 3.0 DESIGN FEATURES (continued)
Table 3-1 (page 7 of 9)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-10 Table 3-1 (page 7 of 9)
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component       Reference             Code             Alternative, Justification & Compensatory ASME Code          Requirement                              Measures Section/Article MPC basket     NG-4420         NG-4427(a) allows     Modify the Code requirement (intended for core assembly                      a fillet weld in any  support structures) with the following text single continuous      prepared to accord with the geometry and stress weld to be less        analysis imperatives for the fuel basket: For the than the specified    longitudinal MPC basket fillet welds, the following fillet weld            criteria apply: 1) The specified fillet weld throat dimension by not      dimension must be maintained over at least 92 more than 1/16        percent of the total weld length. All regions of inch, provided that    undersized weld must be less than 3 inches long the total undersize    and separated from each other by at least 9 portion of the weld    inches. 2) Areas of undercuts and porosity does not exceed        beyond that allowed by the applicable ASME 10 percent of the      Code shall not exceed 1/2 inch in weld length.
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC basket assembly NG-4420 NG-4427(a) allows a fillet weld in any single continuous weld to be less than the specified fillet weld dimension by not more than 1/16 inch, provided that the total undersize portion of the weld does not exceed 10 percent of the length of the weld.
length of the weld. The total length of undercut and porosity over any Individual            1-foot length shall not exceed 2 inches. 3) The undersize weld        total weld length in which items (1) and (2) apply portions shall not    shall not exceed a total of 10 percent of the exceed 2 inches in    overall weld length. The limited access of the length.                MPC basket panel longitudinal fillet welds makes it difficult to perform effective repairs of these welds and creates the potential for causing additional damage to the basket assembly (e.g.,
Individual undersize weld portions shall not exceed 2 inches in length.
Modify the Code requirement (intended for core support structures) with the following text prepared to accord with the geometry and stress analysis imperatives for the fuel basket: For the longitudinal MPC basket fillet welds, the following criteria apply: 1) The specified fillet weld throat dimension must be maintained over at least 92 percent of the total weld length. All regions of undersized weld must be less than 3 inches long and separated from each other by at least 9 inches. 2) Areas of undercuts and porosity beyond that allowed by the applicable ASME Code shall not exceed 1/2 inch in weld length.
The total length of undercut and porosity over any 1-foot length shall not exceed 2 inches. 3) The total weld length in which items (1) and (2) apply shall not exceed a total of 10 percent of the overall weld length. The limited access of the MPC basket panel longitudinal fillet welds makes it difficult to perform effective repairs of these welds and creates the potential for causing additional damage to the basket assembly (e.g.,
to the neutron absorber and its sheathing) if repairs are attempted. The acceptance criteria provided in the foregoing have been established to comport with the objectives of the basket design and preserve the margins demonstrated in the supporting stress analysis.
to the neutron absorber and its sheathing) if repairs are attempted. The acceptance criteria provided in the foregoing have been established to comport with the objectives of the basket design and preserve the margins demonstrated in the supporting stress analysis.
From the structural standpoint, the weld acceptance criteria are established to ensure that any departure from the ideal, continuous fillet weld seam would not alter the primary bending stresses on which the design of the fuel baskets is predicated. Stated differently, the permitted weld discontinuities are limited in size to ensure that they remain classifiable as local stress elevators (peak stress, F, in the ASME Code for which specific stress intensity limits do not apply).
From the structural standpoint, the weld acceptance criteria are established to ensure that any departure from the ideal, continuous fillet weld seam would not alter the primary bending stresses on which the design of the fuel baskets is predicated. Stated differently, the permitted weld discontinuities are limited in size to ensure that they remain classifiable as local stress elevators (peak stress, F, in the ASME Code for which specific stress intensity limits do not apply).
MPC Basket     NG-8000         States                 The HI-STORM100 System is to be marked and Assembly                      requirements for      identified in accordance with 10CFR71 and nameplates,            10CFR72 requirements. Code stamping is not stamping and          required. The MPC basket data package to be reports per            in accordance with Holtec approved QA NCA-8000.              program.
MPC Basket Assembly NG-8000 States requirements for nameplates, stamping and reports per NCA-8000.
OVERPACK       NF-2000         Requires materials     Materials will be supplied by Holtec-approved Steel                          to be supplied by      supplier with CMTRs in accordance with Structure                      ASME-approved          NF-2000 requirements.
The HI-STORM100 System is to be marked and identified in accordance with 10CFR71 and 10CFR72 requirements. Code stamping is not required. The MPC basket data package to be in accordance with Holtec approved QA program.
material supplier.
OVERPACK Steel Structure NF-2000 Requires materials to be supplied by ASME-approved material supplier.
Certificate of Compliance No. 1014                                                  Amendment No. 12 Appendix B                                        3-10
Materials will be supplied by Holtec-approved supplier with CMTRs in accordance with NF-2000 requirements.  


Design Features 3.0 DESIGN FEATURES (continued)
Design Features 3.0 DESIGN FEATURES (continued)
Table 3-1 (page 8 of 9)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-11 Table 3-1 (page 8 of 9)
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component       Reference             Code           Alternative, Justification & Compensatory ASME Code        Requirement                            Measures Section/Article TRANSFER       NF-2000         Requires materials   Materials will be supplied by Holtec-approved CASK Steel                    to be supplied by    supplier with CMTRs in accordance with Structure                      ASME-approved        NF-2000 requirements.
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures TRANSFER CASK Steel Structure NF-2000 Requires materials to be supplied by ASME-approved material supplier.
material supplier.
Materials will be supplied by Holtec-approved supplier with CMTRs in accordance with NF-2000 requirements.
OVERPACK       NF-4441         Requires special     The margins of safety in these welds under Baseplate                      examinations or      loads experienced during lifting operations or and Lid Top                    requirements for    accident conditions are quite large. The Plate                          welds where a        OVERPACK baseplate welds to the inner shell, primary member of    pedestal shell, and radial plates are only loaded thickness 1 inch or  during lifting conditions and have large safety greater is loaded    factors during lifting. Likewise, the top lid plate to transmit loads in to lid shell weld has a large structural margin the through          under the inertia loads imposed during a non-thickness            mechanistic tipover event.
OVERPACK Baseplate and Lid Top Plate NF-4441 Requires special examinations or requirements for welds where a primary member of thickness 1 inch or greater is loaded to transmit loads in the through thickness direction.
direction.
The margins of safety in these welds under loads experienced during lifting operations or accident conditions are quite large. The OVERPACK baseplate welds to the inner shell, pedestal shell, and radial plates are only loaded during lifting conditions and have large safety factors during lifting. Likewise, the top lid plate to lid shell weld has a large structural margin under the inertia loads imposed during a non-mechanistic tipover event.
OVERPACK       NF-3256         Provides             Welds for which no structural credit is taken are Steel          NF-3266        requirements for    identified as Non-NF welds in the design Structure                      welded joints.      drawings. These non-structural welds are specified in accordance with the pre-qualified welds of AWS D1.1. These welds shall be made by welders and weld procedures qualified in accordance with AWS D1.1 or ASME Section IX.
OVERPACK Steel Structure NF-3256 NF-3266 Provides requirements for welded joints.
Welds for which structural credit is taken in the safety analyses shall meet the stress limits for NF-3256.2, but are not required to meet the joint configuration requirements specified in these Code articles. The geometry of the joint designs in the cask structures are based on the fabricability and accessibility of the joint, not generally contemplated by this Code section governing supports.
Welds for which no structural credit is taken are identified as Non-NF welds in the design drawings. These non-structural welds are specified in accordance with the pre-qualified welds of AWS D1.1. These welds shall be made by welders and weld procedures qualified in accordance with AWS D1.1 or ASME Section IX.
Certificate of Compliance No. 1014                                                Amendment No. 12 Appendix B                                      3-11
Welds for which structural credit is taken in the safety analyses shall meet the stress limits for NF-3256.2, but are not required to meet the joint configuration requirements specified in these Code articles. The geometry of the joint designs in the cask structures are based on the fabricability and accessibility of the joint, not generally contemplated by this Code section governing supports.  


Design Features 3.0 DESIGN FEATURES (continued)
Design Features 3.0 DESIGN FEATURES (continued)
Table 3-1 (page 9 of 9)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-12 Table 3-1 (page 9 of 9)
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component       Reference             Code           Alternative, Justification & Compensatory ASME Code        Requirement                            Measures Section/Article HI-STORM       NF-3320         NF-3324.6 and       These Code requirements are applicable to linear OVERPACK      NF-4720        NF-4720 provide      structures wherein bolted joints carry axial, and HI-                        requirements for    shear, as well as rotational (torsional) loads. The TRAC                          bolting              OVERPACK and TRANSFER CASK bolted TRANSFER                                            connections in the structural load path are CASK                                                qualified by design based on the design loadings defined in the FSAR. Bolted joints in these components see no shear or torsional loads under normal storage conditions. Larger clearances between bolts and holes may be necessary to ensure shear interfaces located elsewhere in the structure engage prior to the bolts experiencing shear loadings (which occur only during side impact scenarios).
LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures HI-STORM OVERPACK and HI-TRAC TRANSFER CASK NF-3320 NF-4720 NF-3324.6 and NF-4720 provide requirements for bolting These Code requirements are applicable to linear structures wherein bolted joints carry axial, shear, as well as rotational (torsional) loads. The OVERPACK and TRANSFER CASK bolted connections in the structural load path are qualified by design based on the design loadings defined in the FSAR. Bolted joints in these components see no shear or torsional loads under normal storage conditions.
Larger clearances between bolts and holes may be necessary to ensure shear interfaces located elsewhere in the structure engage prior to the bolts experiencing shear loadings (which occur only during side impact scenarios).
Bolted joints that are subject to shear loads in accident conditions are qualified by appropriate stress analysis. Larger bolt-to-hole clearances help ensure more efficient operations in making these bolted connections, thereby minimizing time spent by operations personnel in a radiation area. Additionally, larger bolt-to-hole clearances allow interchangeability of the lids from one particular fabricated cask to another.
Bolted joints that are subject to shear loads in accident conditions are qualified by appropriate stress analysis. Larger bolt-to-hole clearances help ensure more efficient operations in making these bolted connections, thereby minimizing time spent by operations personnel in a radiation area. Additionally, larger bolt-to-hole clearances allow interchangeability of the lids from one particular fabricated cask to another.
HI-STORM       Section II, SA- Table 1 -           All SA-516 material used in the HI-STORM 100 OVERPACK      516/516A        Chemical            system is required to meet the material and HI-                        requirements        composition described in ASME Code Section TRAC                                                II, 2007 edition. This edition allows for a TRANSFER                                            different manganese content from the 1995 CASK                                                edition, but does not change the structural or thermal properties of the material.
HI-STORM OVERPACK and HI-TRAC TRANSFER CASK Section II, SA-516/516A Table 1 -
Certificate of Compliance No. 1014                                                Amendment No. 12 Appendix B                                      3-12
Chemical requirements All SA-516 material used in the HI-STORM 100 system is required to meet the material composition described in ASME Code Section II, 2007 edition. This edition allows for a different manganese content from the 1995 edition, but does not change the structural or thermal properties of the material.  


Design Features 3.0 DESIGN FEATURES (continued) 3.4     Site-Specific Parameters and Analyses Site-specific parameters and analyses that will require verification by the system user are, as a minimum, as follows:
Design Features 3.0 DESIGN FEATURES (continued)
: 1.     The temperature of 80o F is the maximum average yearly temperature.
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-13 3.4 Site-Specific Parameters and Analyses Site-specific parameters and analyses that will require verification by the system user are, as a minimum, as follows:
: 2.     The allowed temperature extremes, averaged over a 3-day period, shall be greater than -40o F and less than 125o F.
: 1.
: 3.             a.       For storage in freestanding OVERPACKs, the resultant horizontal acceleration (vectorial sum of two horizontal Zero Period Accelerations (ZPAs) at a three-dimensional seismic site), GH, and vertical ZPA, GV, on the top surface of the ISFSI pad, expressed as fractions of g, shall satisfy the following inequality:
The temperature of 80o F is the maximum average yearly temperature.
GH + &#xb5;GV &#xb5; where &#xb5; is either the Coulomb friction coefficient for the cask/ISFSI pad interface or the ratio r/h, where r is the radius of the cask and h is the height of the cask center-of-gravity above the ISFSI pad surface. The above inequality must be met for both definitions of &#xb5;,
: 2.
The allowed temperature extremes, averaged over a 3-day period, shall be greater than -40o F and less than 125o F.
: 3.
: a.
For storage in freestanding OVERPACKs, the resultant horizontal acceleration (vectorial sum of two horizontal Zero Period Accelerations (ZPAs) at a three-dimensional seismic site), GH, and vertical ZPA, GV, on the top surface of the ISFSI pad, expressed as fractions of g, shall satisfy the following inequality:
GH + &#xb5;GV &#xb5; where &#xb5; is either the Coulomb friction coefficient for the cask/ISFSI pad interface or the ratio r/h, where r is the radius of the cask and h is the height of the cask center-of-gravity above the ISFSI pad surface. The above inequality must be met for both definitions of &#xb5;,
but only applies to ISFSIs where the casks are deployed in a freestanding configuration. Unless demonstrated by appropriate testing that a higher coefficient of friction value is appropriate for a specific ISFSI, the value used shall be 0.53. If acceleration time-histories on the ISFSI pad surface are available, GH and GV may be the coincident values of the instantaneous net horizontal and vertical accelerations. If instantaneous accelerations are used, the inequality shall be evaluated at each time step in the acceleration time history over the total duration of the seismic event.
but only applies to ISFSIs where the casks are deployed in a freestanding configuration. Unless demonstrated by appropriate testing that a higher coefficient of friction value is appropriate for a specific ISFSI, the value used shall be 0.53. If acceleration time-histories on the ISFSI pad surface are available, GH and GV may be the coincident values of the instantaneous net horizontal and vertical accelerations. If instantaneous accelerations are used, the inequality shall be evaluated at each time step in the acceleration time history over the total duration of the seismic event.
If this static equilibrium based inequality cannot be met, a dynamic analysis of the cask/ISFSI pad assemblage with appropriate recognition of soil/structure interaction effects shall be performed to ensure that the casks will not tip over or undergo excessive sliding under the sites Design Basis Earthquake.
If this static equilibrium based inequality cannot be met, a dynamic analysis of the cask/ISFSI pad assemblage with appropriate recognition of soil/structure interaction effects shall be performed to ensure that the casks will not tip over or undergo excessive sliding under the sites Design Basis Earthquake.
(continued)
(continued)  
Certificate of Compliance No. 1014                                            Amendment No. 12 Appendix B                                      3-13


Design Features 3.0 DESIGN FEATURES (continued) 3.4     Site-Specific Parameters and Analyses (continued)
Design Features 3.0 DESIGN FEATURES (continued)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-14 3.4 Site-Specific Parameters and Analyses (continued)
: b. For free-standing casks, under environmental conditions that may degrade the pad/cask interface friction (such as due to icing) the response of the casks under the sites Design Basis Earthquake shall be established using the best estimate of the friction coefficient in an appropriate analysis model. The analysis should demonstrate that the earthquake will not result in cask tipover or cause a cask to fall off the pad. In addition, impact between casks should be precluded, or should be considered an accident for which the maximum g-load experienced by the stored fuel shall be limited to 45 gs.
: b. For free-standing casks, under environmental conditions that may degrade the pad/cask interface friction (such as due to icing) the response of the casks under the sites Design Basis Earthquake shall be established using the best estimate of the friction coefficient in an appropriate analysis model. The analysis should demonstrate that the earthquake will not result in cask tipover or cause a cask to fall off the pad. In addition, impact between casks should be precluded, or should be considered an accident for which the maximum g-load experienced by the stored fuel shall be limited to 45 gs.
: c. For those ISFSI sites with design basis seismic acceleration values that may overturn or cause excessive sliding of free-standing casks, the HI-STORM 100 System OVERPACKs shall be anchored to the ISFSI pad. The site seismic characteristics and the anchorage system shall meet the following requirements:
: c.
: i. The site acceleration response spectra at the top of the ISFSI pad shall have ZPAs that meet the following inequalities:
For those ISFSI sites with design basis seismic acceleration values that may overturn or cause excessive sliding of free-standing casks, the HI-STORM 100 System OVERPACKs shall be anchored to the ISFSI pad. The site seismic characteristics and the anchorage system shall meet the following requirements:
GH 2.12 AND GV 1.5 Where:
: i.
The site acceleration response spectra at the top of the ISFSI pad shall have ZPAs that meet the following inequalities:
GH 2.12 AND GV 1.5 Where:
GH is the vectorial sum of the two horizontal ZPAs at a three-dimensional seismic site (or the horizontal ZPA at a two-dimensional site) and GV is the vertical ZPA.
GH is the vectorial sum of the two horizontal ZPAs at a three-dimensional seismic site (or the horizontal ZPA at a two-dimensional site) and GV is the vertical ZPA.
ii. Each HI-STORM 100 dry storage cask shall be anchored with twenty-eight (28), 2-inch diameter studs and compatible nuts of material suitable for the expected ISFSI environment. The studs shall meet the following requirements:
ii.
Yield Strength at Ambient Temperature: 80 ksi Ultimate Strength at Ambient Temperature: 125 ksi Initial Tensile Pre-Stress: 55 ksi AND 65 ksi (continued)
Each HI-STORM 100 dry storage cask shall be anchored with twenty-eight (28), 2-inch diameter studs and compatible nuts of material suitable for the expected ISFSI environment. The studs shall meet the following requirements:
Certificate of Compliance No. 1014                                      Amendment No. 12 Appendix B                                    3-14
Yield Strength at Ambient Temperature: 80 ksi Ultimate Strength at Ambient Temperature: 125 ksi Initial Tensile Pre-Stress: 55 ksi AND 65 ksi (continued)  


Design Features 3.0 DESIGN FEATURES (continued) 3.4   Site-Specific Parameters and Analyses (continued)
Design Features 3.0 DESIGN FEATURES (continued)
NOTE: The above anchorage specifications are required for the seismic spectra defined in item 3.4.3.c.i. Users may use fewer studs or those of different diameter to account for site-specific seismic spectra less severe than those specified above. The embedment design shall comply with Appendix B of ACI-349-97. A later edition of this Code may be used, provided a written reconciliation is performed.
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-15 3.4 Site-Specific Parameters and Analyses (continued)
iii. Embedment Concrete Compressive Strength: 4,000 psi at 28 days
NOTE:
: 4.     The analyzed flood condition of 15 fps water velocity and a height of 125 feet of water (full submergence of the loaded cask) are not exceeded.
The above anchorage specifications are required for the seismic spectra defined in item 3.4.3.c.i. Users may use fewer studs or those of different diameter to account for site-specific seismic spectra less severe than those specified above. The embedment design shall comply with Appendix B of ACI-349-97. A later edition of this Code may be used, provided a written reconciliation is performed.
: 5.     The potential for fire and explosion while handling a loaded OVERPACK or TRANSFER CASK shall be addressed, based on site-specific considerations. The user shall demonstrate that the site-specific potential for fire is bounded by the fire conditions analyzed by the Certificate Holder, or an analysis of the site-specific fire considerations shall be performed.
iii. Embedment Concrete Compressive Strength: 4,000 psi at 28 days
: 6.     a.     For freestanding casks, the ISFSI pad shall be verified by analysis to limit cask deceleration during design basis drop and non-mechanistic tip-over events to 45 gs at the top of the MPC fuel basket. Analyses shall be performed using methodologies consistent with those described in the HI-STORM 100 FSAR. A restriction on the lift and/or drop height is not required if the cask is lifted with a device designed in accordance with applicable stress limits from ANSI N14.6, and/or NUREG-0612, and has redundant drop protection features.
: 4.
: b. For anchored casks, the ISFSI pad shall be designed to meet the embedment requirements of the anchorage design. A cask tip-over event for an anchored cask is not credible. The ISFSI pad shall be verified by analysis to limit cask deceleration during a design basis drop event to 45 gs at the top of the MPC fuel basket, except as provided for in this paragraph below. Analyses shall be performed using methodologies consistent with those described in the HI-STORM 100 FSAR. A restriction on the lift and/or drop height is not required to be established if the cask is lifted with a device designed in accordance with applicable stress limits from ANSI N14.6, and/or NUREG-0612, and has redundant drop protection features.
The analyzed flood condition of 15 fps water velocity and a height of 125 feet of water (full submergence of the loaded cask) are not exceeded.
(continued)
: 5.
Certificate of Compliance No. 1014                                            Amendment No. 12 Appendix B                                        3-15
The potential for fire and explosion while handling a loaded OVERPACK or TRANSFER CASK shall be addressed, based on site-specific considerations. The user shall demonstrate that the site-specific potential for fire is bounded by the fire conditions analyzed by the Certificate Holder, or an analysis of the site-specific fire considerations shall be performed.
: 6.
: a.
For freestanding casks, the ISFSI pad shall be verified by analysis to limit cask deceleration during design basis drop and non-mechanistic tip-over events to 45 gs at the top of the MPC fuel basket. Analyses shall be performed using methodologies consistent with those described in the HI-STORM 100 FSAR. A restriction on the lift and/or drop height is not required if the cask is lifted with a device designed in accordance with applicable stress limits from ANSI N14.6, and/or NUREG-0612, and has redundant drop protection features.
: b.
For anchored casks, the ISFSI pad shall be designed to meet the embedment requirements of the anchorage design. A cask tip-over event for an anchored cask is not credible. The ISFSI pad shall be verified by analysis to limit cask deceleration during a design basis drop event to 45 gs at the top of the MPC fuel basket, except as provided for in this paragraph below. Analyses shall be performed using methodologies consistent with those described in the HI-STORM 100 FSAR. A restriction on the lift and/or drop height is not required to be established if the cask is lifted with a device designed in accordance with applicable stress limits from ANSI N14.6, and/or NUREG-0612, and has redundant drop protection features.
(continued)  


Design Features 3.0 DESIGN FEATURES (continued) 3.4   Site-Specific Parameters and Analyses (continued)
Design Features 3.0 DESIGN FEATURES (continued)
: 7.     In cases where engineered features (i.e., berms and shield walls) are used to ensure that the requirements of 10CFR72.104(a) are met, such features are to be considered important to safety and must be evaluated to determine the applicable quality assurance category.
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-16 3.4 Site-Specific Parameters and Analyses (continued)
: 8.     LOADING OPERATIONS, TRANSPORT OPERATIONS, and UNLOADING OPERATIONS shall only be conducted with working area ambient temperatures 0o F for all MPC heat loads, and
: 7.
: a.     90oF (averaged over a 3-day period) for operations subjected to direct solar heating
In cases where engineered features (i.e., berms and shield walls) are used to ensure that the requirements of 10CFR72.104(a) are met, such features are to be considered important to safety and must be evaluated to determine the applicable quality assurance category.
: b.     110oF (averaged over a 3-day period) for operations not subjected to direct solar heating for all MPC heat loads.
: 8.
: 9.     For those users whose site-specific design basis includes an event or events (e.g., flood) that result in the blockage of any OVERPACK inlet or outlet air ducts for an extended period of time (i.e, longer than the total Completion Time of LCO 3.1.2), an analysis or evaluation may be performed to demonstrate adequate heat removal is available for the duration of the event. Adequate heat removal is defined as fuel cladding temperatures remaining below the short term temperature limit. If the analysis or evaluation is not performed, or if fuel cladding temperature limits are unable to be demonstrated by analysis or evaluation to remain below the short term temperature limit for the duration of the event, provisions shall be established to provide alternate means of cooling to accomplish this objective.
LOADING OPERATIONS, TRANSPORT OPERATIONS, and UNLOADING OPERATIONS shall only be conducted with working area ambient temperatures 0o F for all MPC heat loads, and
: 10. Users shall establish procedural and/or mechanical barriers to ensure that during LOADING OPERATIONS and UNLOADING OPERATIONS, either the fuel cladding is covered by water, or the MPC is filled with an inert gas.
: a.
: 11. Site ambient temperature under HI-TRAC TRANSPORT OPERATIONS shall be evaluated in accordance with Section 3.9 requirements.
90oF (averaged over a 3-day period) for operations subjected to direct solar heating
(continued)
: b.
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                    3-16
110oF (averaged over a 3-day period) for operations not subjected to direct solar heating for all MPC heat loads.
: 9.
For those users whose site-specific design basis includes an event or events (e.g., flood) that result in the blockage of any OVERPACK inlet or outlet air ducts for an extended period of time (i.e, longer than the total Completion Time of LCO 3.1.2), an analysis or evaluation may be performed to demonstrate adequate heat removal is available for the duration of the event. Adequate heat removal is defined as fuel cladding temperatures remaining below the short term temperature limit. If the analysis or evaluation is not performed, or if fuel cladding temperature limits are unable to be demonstrated by analysis or evaluation to remain below the short term temperature limit for the duration of the event, provisions shall be established to provide alternate means of cooling to accomplish this objective.
: 10.
Users shall establish procedural and/or mechanical barriers to ensure that during LOADING OPERATIONS and UNLOADING OPERATIONS, either the fuel cladding is covered by water, or the MPC is filled with an inert gas.
: 11.
Site ambient temperature under HI-TRAC TRANSPORT OPERATIONS shall be evaluated in accordance with Section 3.9 requirements.
(continued)  


Design Features 3.0 DESIGN FEATURES (continued) 3.5   Cask Transfer Facility (CTF) 3.5.1   TRANSFER CASK and MPC Lifters Lifting of a loaded TRANSFER CASK and MPC using devices that are not integral to structures governed by 10 CFR Part 50 shall be performed with a CTF that is designed, operated, fabricated, tested, inspected, and maintained in accordance with the guidelines of NUREG-0612, Control of Heavy Loads at Nuclear Power Plants, as applicable, and the below clarifications. The CTF Structure requirements below do not apply to heavy loads bounded by the regulations of 10 CFR Part 50 or to the loading of an OVERPACK in a belowground restraint system which permits MPC TRANSFER near grade level and does not require an aboveground CTF.
Design Features 3.0 DESIGN FEATURES (continued)
3.5.2   CTF Structure Requirements 3.5.2.1 Cask Transfer Station and Stationary Lifting Devices
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-17 3.5 Cask Transfer Facility (CTF) 3.5.1 TRANSFER CASK and MPC Lifters Lifting of a loaded TRANSFER CASK and MPC using devices that are not integral to structures governed by 10 CFR Part 50 shall be performed with a CTF that is designed, operated, fabricated, tested, inspected, and maintained in accordance with the guidelines of NUREG-0612, Control of Heavy Loads at Nuclear Power Plants, as applicable, and the below clarifications. The CTF Structure requirements below do not apply to heavy loads bounded by the regulations of 10 CFR Part 50 or to the loading of an OVERPACK in a belowground restraint system which permits MPC TRANSFER near grade level and does not require an aboveground CTF.
: 1. The metal weldment structure of the CTF structure shall be designed to comply with the stress limits of ASME Section III, Subsection NF, Class 3 for linear structures. The applicable loads, load combinations, and associated service condition definitions are provided in Table 3-2. All compression loaded members shall satisfy the buckling criteria of ASME Section III, Subsection NF.
3.5.2 CTF Structure Requirements 3.5.2.1 Cask Transfer Station and Stationary Lifting Devices
: 2. If a portion of the CTF structure is constructed of reinforced concrete, then the factored load combinations set forth in ACI-318 (89) for the loads defined in Table 3-2 shall apply.
: 1.
: 3. The TRANSFER CASK and MPC lifting device used with the CTF shall be designed, fabricated, operated, tested, inspected and maintained in accordance with NUREG-0612, Section 5.1.
The metal weldment structure of the CTF structure shall be designed to comply with the stress limits of ASME Section III, Subsection NF, Class 3 for linear structures. The applicable loads, load combinations, and associated service condition definitions are provided in Table 3-2. All compression loaded members shall satisfy the buckling criteria of ASME Section III, Subsection NF.
: 4. The CTF shall be designed, constructed, and evaluated to ensure that if the MPC is dropped during inter-cask transfer operations, its confinement boundary would not be breached. This requirement applies to CTFs with either stationary or mobile lifting devices.
: 2.
(continued)
If a portion of the CTF structure is constructed of reinforced concrete, then the factored load combinations set forth in ACI-318 (89) for the loads defined in Table 3-2 shall apply.
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      3-17
: 3.
The TRANSFER CASK and MPC lifting device used with the CTF shall be designed, fabricated, operated, tested, inspected and maintained in accordance with NUREG-0612, Section 5.1.
: 4.
The CTF shall be designed, constructed, and evaluated to ensure that if the MPC is dropped during inter-cask transfer operations, its confinement boundary would not be breached. This requirement applies to CTFs with either stationary or mobile lifting devices.
(continued)  


Design Features 3.0 DESIGN FEATURES (continued) 3.5   Cask Transfer Facility (CTF) (continued) 3.5.2.2   Mobile Lift Devices If a mobile lifting device is used as the lifting device, in lieu of a stationary lifting device, it shall meet the guidelines of NUREG-0612, Section 5.1, with the following clarifications:
Design Features 3.0 DESIGN FEATURES (continued)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-18 3.5 Cask Transfer Facility (CTF) (continued) 3.5.2.2 Mobile Lift Devices If a mobile lifting device is used as the lifting device, in lieu of a stationary lifting device, it shall meet the guidelines of NUREG-0612, Section 5.1, with the following clarifications:
: 1. Mobile lifting devices shall have a minimum safety factor of two over the allowable load table for the lifting device in accordance with the guidance of NUREG-0612, Section 5.1.6(1)(a) and shall be capable of stopping and holding the load during a Design Basis Earthquake (DBE) event.
: 1. Mobile lifting devices shall have a minimum safety factor of two over the allowable load table for the lifting device in accordance with the guidance of NUREG-0612, Section 5.1.6(1)(a) and shall be capable of stopping and holding the load during a Design Basis Earthquake (DBE) event.
: 2. Mobile lifting devices shall conform to meet the requirements of ANSI B30.5, Mobile and Locomotive Cranes, in lieu of the requirements of ANSI B30.2, Overhead and Gantry Cranes.
: 2. Mobile lifting devices shall conform to meet the requirements of ANSI B30.5, Mobile and Locomotive Cranes, in lieu of the requirements of ANSI B30.2, Overhead and Gantry Cranes.
: 3. Mobile cranes are not required to meet the requirements of NUREG-0612, Section 5.1.6(2) for new cranes.
: 3. Mobile cranes are not required to meet the requirements of NUREG-0612, Section 5.1.6(2) for new cranes.
: 4. Horizontal movements of the TRANSFER CASK and MPC using a mobile crane are prohibited.
: 4. Horizontal movements of the TRANSFER CASK and MPC using a mobile crane are prohibited.
(continued)
(continued)  
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                    3-18


Design Features 3.0 DESIGN FEATURES (continued) 3.5     Cask Transfer Facility (CTF)(continued)
Design Features 3.0 DESIGN FEATURES (continued)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-19 3.5 Cask Transfer Facility (CTF)(continued)
Table 3-2 Load Combinations and Service Condition Definitions for the CTF Structure (Note 1)
Table 3-2 Load Combinations and Service Condition Definitions for the CTF Structure (Note 1)
Load Combination           ASME III Service Condition                 Comment for Definition of Allowable Stress D*                                                 All primary load bearing Level A                          members must satisfy Level A D+S                                                  stress limits D + M + W (Note 2)
Load Combination ASME III Service Condition for Definition of Allowable Stress Comment D*
D+F               Level D                           Factor of safety against overturning shall be 1.1 D+E D+Y D = Dead load D* = Apparent dead load S = Snow and ice load for the CTF site M = Tornado missile load for the CTF site W = Tornado wind load for the CTF site F = Flood load for the CTF site E = Seismic load for the CTF site Y = Tsunami load for the CTF site Notes:     1. The reinforced concrete portion of the CTF structure shall also meet the factored combinations of loads set forth in ACI-318(89).
D + S Level A All primary load bearing members must satisfy Level A stress limits D + M + W (Note 2)
: 2. Tornado missile load may be reduced or eliminated based on a PRA for the CTF site.
D + F D + E D + Y Level D Factor of safety against overturning shall be 1.1 D = Dead load D* = Apparent dead load S = Snow and ice load for the CTF site M = Tornado missile load for the CTF site W = Tornado wind load for the CTF site F = Flood load for the CTF site E = Seismic load for the CTF site Y = Tsunami load for the CTF site Notes:
Certificate of Compliance No. 1014                                           Amendment No. 12 Appendix B                                     3-19
: 1.
The reinforced concrete portion of the CTF structure shall also meet the factored combinations of loads set forth in ACI-318(89).
: 2.
Tornado missile load may be reduced or eliminated based on a PRA for the CTF site.  
 
Design Features 3.0 DESIGN FEATURES (continued)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-20 3.6 Forced Helium Dehydration System 3.6.1


Design Features 3.0 DESIGN FEATURES (continued) 3.6    Forced Helium Dehydration System 3.6.1    System Description Use of a forced helium dehydration (FHD) system, (a closed-loop system) is an alternative to vacuum drying the MPC for moderate burnup fuel (
===System Description===
Use of a forced helium dehydration (FHD) system, (a closed-loop system) is an alternative to vacuum drying the MPC for moderate burnup fuel (
45,000 MWD/MTU) with lower MPC heat load and mandatory for drying MPCs containing one or more high burnup fuel assemblies or higher MPC heat loads as indicated in Appendix A Table 3-1. The FHD system shall be designed for normal operation (i.e., excluding startup and shutdown ramps) in accordance with the criteria in Section 3.6.2.
45,000 MWD/MTU) with lower MPC heat load and mandatory for drying MPCs containing one or more high burnup fuel assemblies or higher MPC heat loads as indicated in Appendix A Table 3-1. The FHD system shall be designed for normal operation (i.e., excluding startup and shutdown ramps) in accordance with the criteria in Section 3.6.2.
3.6.2   Design Criteria 3.6.2.1 The temperature of the helium gas in the MPC shall be at least 15oF higher than the saturation temperature at coincident pressure.
3.6.2 Design Criteria 3.6.2.1 The temperature of the helium gas in the MPC shall be at least 15oF higher than the saturation temperature at coincident pressure.
3.6.2.2 The pressure in the MPC cavity space shall be 60.3 psig (75 psia) during drying. Backfill pressures shall be as described in Appendix A.
3.6.2.2 The pressure in the MPC cavity space shall be 60.3 psig (75 psia) during drying. Backfill pressures shall be as described in Appendix A.
3.6.2.3 The hourly recirculation rate of helium shall be 10 times the nominal helium mass backfilled into the MPC for fuel storage operations.
3.6.2.3 The hourly recirculation rate of helium shall be 10 times the nominal helium mass backfilled into the MPC for fuel storage operations.
3.6.2.4 The partial pressure of the water vapor in the MPC cavity will not exceed 3 torr. The limit is met if the gas temperature at the demoisturizer outlet is verified by measurement to remain 21oF for a period of 30 minutes or if the dew point of the gas exiting the MPC is verified by measurement to remain 22.9oF for 30 minutes.
3.6.2.4 The partial pressure of the water vapor in the MPC cavity will not exceed 3 torr. The limit is met if the gas temperature at the demoisturizer outlet is verified by measurement to remain 21oF for a period of 30 minutes or if the dew point of the gas exiting the MPC is verified by measurement to remain 22.9oF for 30 minutes.
3.6.2.5 The condensing module shall be designed to de-vaporize the recirculating helium gas to a dew point 120oF.
3.6.2.5 The condensing module shall be designed to de-vaporize the recirculating helium gas to a dew point 120oF.
3.6.2.6 The demoisturizing module shall be configured to be introduced into its helium conditioning function after the condensing module has been operated for the required length of time to assure that the bulk moisture vaporization in the MPC (defined as Phase 1 in FSAR Appendix 2.B) has been completed.
3.6.2.6 The demoisturizing module shall be configured to be introduced into its helium conditioning function after the condensing module has been operated for the required length of time to assure that the bulk moisture vaporization in the MPC (defined as Phase 1 in FSAR Appendix 2.B) has been completed.
3.6.2.7 The helium circulator shall be sized to effect the minimum flow rate of circulation required by these design criteria.
3.6.2.7 The helium circulator shall be sized to effect the minimum flow rate of circulation required by these design criteria.
3.6.2.8 The pre-heater module shall be engineered to ensure that the temperature of the helium gas in the MPC meets these design criteria.
3.6.2.8 The pre-heater module shall be engineered to ensure that the temperature of the helium gas in the MPC meets these design criteria.  
Certificate of Compliance No. 1014                                          Amendment No. 12 Appendix B                                      3-20


Design Features 3.0 DESIGN FEATURES (continued) 3.6   Forced Helium Dehydration System (continued) 3.6.3   Fuel Cladding Temperature A steady-state thermal analysis of the MPC under the forced helium flow scenario shall be performed using the methodology described in HI-STORM 100 FSAR Section 4.4, with due recognition of the forced convection process during FHD system operation. This analysis shall demonstrate that the peak temperature of the fuel cladding, under the most adverse condition of FHD system operation, is below the peak cladding temperature limit for normal conditions of storage for the applicable fuel type (PWR or BWR) and cooling time at the start of dry storage.
Design Features 3.0 DESIGN FEATURES (continued)
3.6.4   Pressure Monitoring During FHD Malfunction During an FHD malfunction event, described in HI-STORM 100 FSAR Chapter 11 as a loss of helium circulation, the system pressure must be monitored to ensure that the conditions listed therein are met.
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-21 3.6 Forced Helium Dehydration System (continued) 3.6.3 Fuel Cladding Temperature A steady-state thermal analysis of the MPC under the forced helium flow scenario shall be performed using the methodology described in HI-STORM 100 FSAR Section 4.4, with due recognition of the forced convection process during FHD system operation. This analysis shall demonstrate that the peak temperature of the fuel cladding, under the most adverse condition of FHD system operation, is below the peak cladding temperature limit for normal conditions of storage for the applicable fuel type (PWR or BWR) and cooling time at the start of dry storage.
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                  3-21
3.6.4 Pressure Monitoring During FHD Malfunction During an FHD malfunction event, described in HI-STORM 100 FSAR Chapter 11 as a loss of helium circulation, the system pressure must be monitored to ensure that the conditions listed therein are met.  


Design Features 3.0 DESIGN FEATURES (continued) 3.7   Supplemental Cooling System 3.7.1   System Description A supplemental cooling system (SCS) is an external system for cooling the MPC inside the HI-TRAC transfer cask during on-site transport. The SCS is required for transport of high burnup fuel under certain heat load conditions defined in Table 3-3. The SCS shall be designed for normal operation (i.e., excluding startup and shutdown ramps) in accordance with the criteria in Section 3.7.2.
Design Features 3.0 DESIGN FEATURES (continued)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-22 3.7 Supplemental Cooling System 3.7.1  
 
===System Description===
A supplemental cooling system (SCS) is an external system for cooling the MPC inside the HI-TRAC transfer cask during on-site transport. The SCS is required for transport of high burnup fuel under certain heat load conditions defined in Table 3-3. The SCS shall be designed for normal operation (i.e., excluding startup and shutdown ramps) in accordance with the criteria in Section 3.7.2.
3.7.2 Design Criteria 3.7.2.1 Not Used.
3.7.2 Design Criteria 3.7.2.1 Not Used.
3.7.2.2 If water is used as the coolant, the system shall be sized to limit the coolant temperature to below 180&#xba;F under steady-state conditions for the design basis heat load at an ambient air temperature of 110&#xba;F. Any electric motors shall have a backup power supply for uninterrupted operation.
3.7.2.2 If water is used as the coolant, the system shall be sized to limit the coolant temperature to below 180&#xba;F under steady-state conditions for the design basis heat load at an ambient air temperature of 110&#xba;F. Any electric motors shall have a backup power supply for uninterrupted operation.
Line 1,003: Line 3,319:
3.7.2.4 All passive components such as tubular heat exchangers, manually operated valves and fittings shall be designed to applicable standards (TEMA, ANSI).
3.7.2.4 All passive components such as tubular heat exchangers, manually operated valves and fittings shall be designed to applicable standards (TEMA, ANSI).
3.7.2.5 The heat dissipation capacity of the SCS shall be equal to or greater than the minimum necessary to ensure that the peak cladding temperature is below 400&#xba;C (752&#xba;F). All heat transfer surfaces in heat exchangers shall be assumed to be fouled to the maximum limits specified in a widely used heat exchange equipment standard such as the Standards of Tubular Exchanger Manufacturers Association.
3.7.2.5 The heat dissipation capacity of the SCS shall be equal to or greater than the minimum necessary to ensure that the peak cladding temperature is below 400&#xba;C (752&#xba;F). All heat transfer surfaces in heat exchangers shall be assumed to be fouled to the maximum limits specified in a widely used heat exchange equipment standard such as the Standards of Tubular Exchanger Manufacturers Association.
3.7.2.6 The coolant utilized to extract heat from the MPC shall be high purity water or air. Antifreeze may be used to prevent water from freezing if warranted by operating conditions. (continued)
3.7.2.6 The coolant utilized to extract heat from the MPC shall be high purity water or air. Antifreeze may be used to prevent water from freezing if warranted by operating conditions. (continued)  
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                      3-22


Design Features 3.0 DESIGN FEATURES (continued) 3.7     Supplemental Cooling System (continued) 3.7.2.7 All pressure boundaries (as defined in the ASME Boiler and Pressure Vessel Code, Section VIII Division 1) shall have pressure ratings that are greater than the maximum system operating pressure by at least 15 psi.
Design Features 3.0 DESIGN FEATURES (continued)
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-23 3.7 Supplemental Cooling System (continued) 3.7.2.7 All pressure boundaries (as defined in the ASME Boiler and Pressure Vessel Code, Section VIII Division 1) shall have pressure ratings that are greater than the maximum system operating pressure by at least 15 psi.
3.7.2.8 All ASME Code components shall comply with Section VIII Division 1 of the ASME Boiler and Pressure Vessel Code.
3.7.2.8 All ASME Code components shall comply with Section VIII Division 1 of the ASME Boiler and Pressure Vessel Code.
3.7.2.9 All gasketed and packed joints shall have a minimum design pressure rating of the pump shut-off pressure plus 15 psi.
3.7.2.9 All gasketed and packed joints shall have a minimum design pressure rating of the pump shut-off pressure plus 15 psi.  
Certificate of Compliance No. 1014                                      Amendment No. 12 Appendix B                                  3-23


Design Features 3.0 DESIGN FEATURES (continued)
Design Features 3.0 DESIGN FEATURES (continued)
Table 3-3 Requirements for Supplemental Cooling System Criteria for use of SCS                       Requirement MPC-68M                                 Not required MPC containing one or more high Burnup fuel assemblies (> 45,000 MWD/MTU) and                                     Yes Heat loads more than 90% of maximum permissible heat loads defined in Section 2.4 under higher helium backfill limits in Table 3-2 of Appendix A MPC containing one or more high Burnup                         Yes fuel assemblies (> 45,000 MWD/MTU) and Heat loads more than 90% of heat load limits in Tables 3-3 or 3-4 of Appendix A under lower helium backfill limits in Table 3-2 of Appendix A Certificate of Compliance No. 1014                                    Amendment No. 12 Appendix B                                    3-24
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-24 Table 3-3 Requirements for Supplemental Cooling System Criteria for use of SCS Requirement MPC-68M Not required MPC containing one or more high Burnup fuel assemblies (> 45,000 MWD/MTU) and Heat loads more than 90% of maximum permissible heat loads defined in Section 2.4 under higher helium backfill limits in Table 3-2 of Appendix A Yes MPC containing one or more high Burnup fuel assemblies (> 45,000 MWD/MTU) and Heat loads more than 90% of heat load limits in Tables 3-3 or 3-4 of Appendix A under lower helium backfill limits in Table 3-2 of Appendix A Yes


Design Features 3.0 DESIGN FEATURES (continued) 3.8     Combustible Gas Monitoring During MPC Lid Welding and Cutting During MPC lid-to-shell welding and cutting operations, combustible gas monitoring of the space under the MPC lid is required, to ensure that there is no combustible mixture present.
Design Features 3.0 DESIGN FEATURES (continued)
3.9     Environmental Temperature Requirements Short term operations involving the HI-TRAC transfer cask can be carried out if the reference ambient temperature (three day average around the cask) is below the Threshold Temperature of 110 deg. F ambient temperature, applicable during HI-TRAC transfer operations inside the 10 CFR Part 50 or 10 CFR Part 52 structural boundary and 90 deg. F outside of it. The determination of the Threshold Temperature compliance shall be made based on the best available thermal data for the site.
Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-25 3.8 Combustible Gas Monitoring During MPC Lid Welding and Cutting During MPC lid-to-shell welding and cutting operations, combustible gas monitoring of the space under the MPC lid is required, to ensure that there is no combustible mixture present.
3.9 Environmental Temperature Requirements Short term operations involving the HI-TRAC transfer cask can be carried out if the reference ambient temperature (three day average around the cask) is below the Threshold Temperature of 110 deg. F ambient temperature, applicable during HI-TRAC transfer operations inside the 10 CFR Part 50 or 10 CFR Part 52 structural boundary and 90 deg. F outside of it. The determination of the Threshold Temperature compliance shall be made based on the best available thermal data for the site.
If the reference ambient temperature exceeds the corresponding Threshold Temperature then a site specific analysis shall be performed using the actual heat load and reference ambient temperature equal to the three day average to ensure that the steady state peak fuel cladding temperature will remain below the 400&deg;C limit. If the peak fuel cladding temperature exceeds 400&deg;C limit then the operation of a Supplemental Cooling System (SCS) in accordance with LCO 3.1.4 is mandatory.
If the reference ambient temperature exceeds the corresponding Threshold Temperature then a site specific analysis shall be performed using the actual heat load and reference ambient temperature equal to the three day average to ensure that the steady state peak fuel cladding temperature will remain below the 400&deg;C limit. If the peak fuel cladding temperature exceeds 400&deg;C limit then the operation of a Supplemental Cooling System (SCS) in accordance with LCO 3.1.4 is mandatory.
SCS operation is mandatory if site data is not available or if a user elects to deploy Supplemental Cooling in lieu of site ambient temperature evaluation.
SCS operation is mandatory if site data is not available or if a user elects to deploy Supplemental Cooling in lieu of site ambient temperature evaluation.}}
Certificate of Compliance No. 1014                                        Amendment No. 12 Appendix B                                  3-25}}

Latest revision as of 04:52, 6 January 2025

Enclosure 3: Proposed CoC 1014 Amendment 12 Appendix B: (Memorandum to K. Morgan-Butler User Need for Rulemaking for the Holtec Hi-Storm 100 Cask System, Amendment No. 12)
ML18087A059
Person / Time
Site: Holtec
Issue date: 12/12/2018
From: John Mckirgan
Spent Fuel Licensing Branch
To:
Chen Y
Shared Package
ML18087A055 List:
References
CAC 001028, EPID L-2017-LLA-0028
Download: ML18087A059 (100)


Text

PROPOSED CERTIFICATE OF COMPLIANCE NO. 1014 APPENDIX B APPROVED CONTENTS AND DESIGN FEATURES FOR THE HI-STORM 100 CASK SYSTEM

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B i

TABLE OF CONTENTS 1.0 DEFINITIONS...................................................................................................................1-1 2.0 APPROVED CONTENTS.................................................................................................2-1 2.1 Fuel Specification and Loading Conditions...................................................................2-1 2.2 Violations......................................................................................................................2-2 2.3 Not Used.......................................................................................................................2-2 2.4 Decay Heat, Burnup & Cooling Time Limits for ZR Clad Fuel..................................... 2-48 Figure 2.1-1 Fuel Loading Regions - MPC-24..................................................................2-3 Figure 2.1-2 Fuel Loading Regions - MPC-24E/24EF......................................................2-4 Figure 2.1-3 Fuel Loading Regions - MPC-32/32F...........................................................2-5 Figure 2.1-4 Fuel Loading Regions - MPC-68/68FF/68M.................................................2-6 Figure 2.4-1 Per Cell Allowable Heat Loads (kW) - MPC-68M........................................ 2-71 Table 2.1-1 Fuel Assembly Limits....................................................................................2-7 Table 2.1-2 PWR Fuel Assembly Characteristics.......................................................... 2-37 Table 2.1-3 BWR Fuel Assembly Characteristics.......................................................... 2-42 Table 2.1-4 Table Deleted....................................................................................................

Table 2.1-5 Table Deleted....................................................................................................

Table 2.1-6 Table Deleted....................................................................................................

Table 2.1-7 Table Deleted....................................................................................................

Table 2.1-8 Non-Fuel Hardware Cooling and Average Burnup...................................... 2-47 Table 2.4-1 Maximum Allowable Decay Heat per Fuel Storage Location....................... 2-48 Table 2.4-2 Fuel Storage Locations per MPC................................................................ 2-50 Table 2.4-3 PWR Fuel Assembly Cooling Time-Dependent Coefficients....................... 2-53 Table 2.4-4 BWR Fuel Assembly Cooling Time-Dependent Coefficients....................... 2-61 Table 2.4-5 Heat Load for Damaged Fuel Assemblies and Fuel Debris under Regionalized Loading..................................................................................2-50 3.0 DESIGN FEATURES........................................................................................................3-1 3.1 Site...............................................................................................................................3-1 3.2 Design Features Important for Criticality Control..........................................................3-1 3.3 Codes and Standards...................................................................................................3-2 3.4 Site Specific Parameters and Analyses...................................................................... 3-13 3.5 Cask Transfer Facility (CTF)....................................................................................... 3-17 3.6 Forced Helium Dehydration System........................................................................... 3-20 3.7 Supplemental Cooling System.................................................................................... 3-22 3.8 Combustible Gas Monitoring During MPC Lid Welding and Cutting............................ 3-25 3.9 Environmental Temperature Requirements................................................................ 3-25 Table 3-1 List of ASME Code Alternatives for HI-STORM 100 Cask System....................3-4 Table 3-2 Load Combinations and Service Condition Definitions for the CTF Structure................................................................................................. 3-19 Table 3-3 Requirements for Supplemental Cooling System............................................ 3-24

Definitions 1.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 1-1 1.0 Definitions Refer to Appendix A for Definitions.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-1 2.0 APPROVED CONTENTS 2.1 Fuel Specifications and Loading Conditions 2.1.1 Fuel To Be Stored In The HI-STORM 100 SFSC System

a.

INTACT FUEL ASSEMBLIES, UNDAMAGED FUEL ASSEMBLIES, DAMAGED FUEL ASSEMBLIES, FUEL DEBRIS, and NON-FUEL HARDWARE meeting the limits specified in Table 2.1-1 and other referenced tables may be stored in the HI-STORM 100 SFSC System.

b.

For MPCs partially loaded with stainless steel clad fuel assemblies, all remaining fuel assemblies in the MPC shall meet the decay heat generation limit for the stainless steel clad fuel assemblies.

c.

For MPCs partially loaded with array/class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A fuel assemblies, all remaining ZR clad INTACT FUEL ASSEMBLIES in the MPC shall meet the decay heat generation limits for the 6x6A, 6x6B, 6x6C, 7x7A and 8x8A fuel assemblies.

d.

All BWR fuel assemblies may be stored with or without ZR channels with the exception of array/class 10x10D and 10x10E fuel assemblies, which may be stored with or without ZR or stainless steel channels.

2.1.2 Uniform Fuel Loading Any authorized fuel assembly may be stored in any fuel storage location, subject to other restrictions related to DAMAGED FUEL, FUEL DEBRIS, and NON-FUEL HARDWARE specified in the CoC.

(continued)

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-2 2.0 Approved Contents 2.1 Fuel Specifications and Loading Conditions (contd) 2.1.3 Regionalized Fuel Loading Users may choose to store fuel using regionalized loading in lieu of uniform loading to allow higher heat emitting fuel assemblies to be stored than would otherwise be able to be stored using uniform loading. Figures 2.1-1 through 2.1-4 define the regions for the MPC-24, MPC-24E, MPC-24EF, MPC-32, MPC-32F, MPC-68, MPC-68FF, and MPC-68M models, respectively1. Fuel assemblydecay heat limits for regionalized loading are specified in Section 2.4.2. Fuel assemblies used in regionalized loading shall meet all other applicable limits specified in Tables 2.1-1 through 2.1-3.

2.2 Violations If any Fuel Specifications or Loading Conditions of 2.1 are violated, the following actions shall be completed:

2.2.1 The affected fuel assemblies shall be placed in a safe condition.

2.2.2 Within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, notify the NRC Operations Center.

2.2.3 Within 30 days, submit a special report which describes the cause of the violation, and actions taken to restore compliance and prevent recurrence.

2.3 Not Used 1

These figures are only intended to distinguish the fuel loading regions. Other details of the basket design are illustrative and may not reflect the actual basket design details.

The design drawings should be consulted for basket design details.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-3 Figure 2.1-1 Fuel Loading Regions - MPC-24

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-4 Figure 2.1-2 Fuel Loading Regions - MPC-24E/24EF

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-5 Figure 2.1-3 Fuel Loading Regions - MPC-32/32F

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-6 Figure 2.1-4 Fuel Loading Regions - MPC-68/68FF/68M

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-7 Table 2.1-1 (page 1 of 30)

Fuel Assembly Limits I. MPC MODEL: MPC-24 A. Allowable Contents

1. Uranium oxide, PWR INTACT FUEL ASSEMBLIES listed in Table 2.1-2, with or without NON-FUEL HARDWARE and meeting the following specifications (Note 1):
a. Cladding Type:

ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class.

b. Initial Enrichment:

As specified in Table 2.1-2 for the applicable fuel assembly array/class.

c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
i. Array/Classes 14x14D,14x14E, and 15x15G Cooling time 8 years and an average burnup 40,000 MWD/MTU.

ii. All Other Array/Classes Cooling time and average burnup as specified in Section 2.4.

ii. NON-FUEL HARDWARE As specified in Table 2.1-8.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-8 Table 2.1-1 (page 2 of 30)

Fuel Assembly Limits I. MPC MODEL: MPC-24 (continued)

A. Allowable Contents (continued)

d. Decay Heat Per Fuel Storage Location:
i. Array/Classes 14x14D, 14x14E, and 15x15G 710 Watts ii. All Other Array/Classes As specified in Section 2.4.
e. Fuel Assembly Length:

176.8 inches (nominal design)

f. Fuel Assembly Width:

8.54 inches (nominal design)

g. Fuel Assembly Weight:

1720 lbs (including NON-FUEL HARDWARE) for assemblies that do not require fuel spacers, otherwise 1680 lbs (including NON-FUEL HARDWARE)

B. Quantity per MPC: Up to 24 fuel assemblies.

C. Deleted.

D. DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS are not authorized for loading into the MPC-24.

E. One NSA is authorized for loading into the MPC-24.

Note 1:

Fuel assemblies containing BPRAs, TPDs, WABAs, water displacement guide tube plugs, orifice rod assemblies, or vibration suppressor inserts with or without ITTRs, may be stored in any fuel storage location. Fuel assemblies containing APSRs or NSAs may only be loaded in fuel storage locations 9, 10, 15, and/or 16. Fuel assemblies containing CRAs, RCCAs, CEAs may only be stored in fuel storage locations 4, 5, 8 - 11, 14 - 17, 20 and/or 21 (see Figure 2.1-1). These requirements are in addition to any other requirements specified for uniform or regionalized fuel loading.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-9 Table 2.1-1 (page 3 of 30)

Fuel Assembly Limits II. MPC MODEL: MPC-68F A. Allowable Contents

1. Uranium oxide, BWR INTACT FUEL ASSEMBLIES, with or without ZR channels. Uranium oxide BWR INTACT FUEL ASSEMBLIES shall meet the criteria specified in Table 2.1-3 for fuel assembly array class 6x6A, 6x6C, 7x7A or 8x8A, and meet the following specifications:
a. Cladding Type:

ZR

b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:

As specified in Table 2.1-3 for the applicable fuel assembly array/class.

c. Initial Maximum Rod Enrichment:

As specified in Table 2.1-3 for the applicable fuel assembly array/class.

d. Post-irradiation Cooling Time and Average Burnup Per Assembly:

Cooling time 18 years and an average burnup 30,000 MWD/MTU.

e. Decay Heat Per Assembly 115 Watts
f. Fuel Assembly Length:

135.0 inches (nominal design)

g. Fuel Assembly Width:

4.70 inches (nominal design)

h. Fuel Assembly Weight:

400 lbs, including channels

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-10 Table 2.1-1 (page 4 of 30)

Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)

A. Allowable Contents (continued)

2. Uranium oxide, BWR DAMAGED FUEL ASSEMBLIES, with or without ZR channels, placed in DAMAGED FUEL CONTAINERS. Uranium oxide BWR DAMAGED FUEL ASSEMBLIES shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6A, 6x6C, 7x7A, or 8x8A, and meet the following specifications:
a. Cladding Type:

ZR

b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:

As specified in Table 2.1-3 for the applicable fuel assembly array/class.

c. Initial Maximum Rod Enrichment:

As specified in Table 2.1-3 for the applicable fuel assembly array/class.

d. Post-irradiation Cooling Time and Average Burnup Per Assembly:

Cooling time 18 years and an average burnup 30,000 MWD/MTU.

e. Decay Heat Per Assembly:

115 Watts

f. Fuel Assembly Length:

135.0 inches (nominal design)

g. Fuel Assembly Width:

4.70 inches (nominal design)

h. Fuel Assembly Weight:

550 lbs, including channels and DFC

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-11 Table 2.1-1 (page 5 of 30)

Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)

A. Allowable Contents (continued)

3. Uranium oxide, BWR FUEL DEBRIS, with or without ZR channels, placed in DAMAGED FUEL CONTAINERS. The original fuel assemblies for the uranium oxide BWR FUEL DEBRIS shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6A, 6x6C, 7x7A, or 8x8A, and meet the following specifications:
a. Cladding Type:

ZR

b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:

As specified in Table 2.1-3 for the applicable original fuel assembly array/class.

c. Initial Maximum Rod Enrichment:

As specified in Table 2.1-3 for the applicable original fuel assembly array/class.

d. Post-irradiation Cooling Time and Average Burnup Per Assembly Cooling time 18 years and an average burnup 30,000 MWD/MTU for the original fuel assembly.
e. Decay Heat Per Assembly 115 Watts
f. Original Fuel Assembly Length 135.0 inches (nominal design)
g. Original Fuel Assembly Width 4.70 inches (nominal design)
h. Fuel Debris Weight 550 lbs, including channels and DFC

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-12 Table 2.1-1 (page 6 of 30)

Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)

A. Allowable Contents (continued)

4. Mixed oxide (MOX), BWR INTACT FUEL ASSEMBLIES, with or without ZR channels. MOX BWR INTACT FUEL ASSEMBLIES shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6B, and meet the following specifications:
a. Cladding Type:

ZR

b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:

As specified in Table 2.1-3 for fuel assembly array/class 6x6B.

c. Initial Maximum Rod Enrichment:

As specified in Table 2.1-3 for fuel assembly array/class 6x6B.

d. Post-irradiation Cooling Time and Average Burnup Per Assembly:

Cooling time 18 years and an average burnup 30,000 MWD/MTIHM.

e. Decay Heat Per Assembly 115 Watts
f. Fuel Assembly Length:

135.0 inches (nominal design)

g. Fuel Assembly Width:

4.70 inches (nominal design)

h. Fuel Assembly Weight:

400 lbs, including channels

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-13 Table 2.1-1 (page 7 of 30)

Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)

A. Allowable Contents (continued)

5. Mixed oxide (MOX), BWR DAMAGED FUEL ASSEMBLIES, with or without ZR channels, placed in DAMAGED FUEL CONTAINERS. MOX BWR DAMAGED FUEL ASSEMBLIES shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6B, and meet the following specifications:
a. Cladding Type:

ZR

b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:

As specified in Table 2.1-3 for fuel assembly array/class 6x6B.

c. Initial Maximum Rod Enrichment:

As specified in Table 2.1-3 for fuel assembly array/class 6x6B.

d. Post-irradiation Cooling Time and Average Burnup Per Assembly:

Cooling time 18 years and an average burnup 30,000 MWD/MTIHM.

e. Decay Heat Per Assembly 115 Watts
f. Fuel Assembly Length:

135.0 inches (nominal design)

g. Fuel Assembly Width:

4.70 inches (nominal design)

h. Fuel Assembly Weight:

550 lbs, including channels and DFC

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-14 Table 2.1-1 (page 8 of 30)

Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)

A. Allowable Contents (continued)

6. Mixed Oxide (MOX), BWR FUEL DEBRIS, with or without ZR channels, placed in DAMAGED FUEL CONTAINERS. The original fuel assemblies for the MOX BWR FUEL DEBRIS shall meet the criteria specified in Table 2.1-3 for fuel assembly array/class 6x6B, and meet the following specifications:
a. Cladding Type:

ZR

b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:

As specified in Table 2.1-3 for original fuel assembly array/class 6x6B.

c. Initial Maximum Rod Enrichment:

As specified in Table 2.1-3 for original fuel assembly array/class 6x6B.

d. Post-irradiation Cooling Time and Average Burnup Per Assembly:

Cooling time 18 years and an average burnup 30,000 MWD/MTIHM for the original fuel assembly.

e. Decay Heat Per Assembly 115 Watts
f. Original Fuel Assembly Length:

135.0 inches (nominal design)

g. Original Fuel Assembly Width:

4.70 inches (nominal design)

h. Fuel Debris Weight:

550 lbs, including channels and DFC

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-15 Table 2.1-1 (page 9 of 30)

Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)

A. Allowable Contents (continued)

7. Thoria rods (ThO2 and UO2) placed in Dresden Unit 1 Thoria Rod Canisters and meeting the following specifications:
a. Cladding Type:

ZR

b. Composition:

98.2 wt.% ThO2, 1.8 wt. % UO2 with an enrichment of 93.5 wt. % 235U.

OR 98.5 wt.% ThO2, 1.5 wt.% UO2 with an enrichment of 93.5 wt.% 235U

c. Number of Rods Per Thoria Rod Canister:

18

d. Decay Heat Per Thoria Rod Canister:

115 Watts

e. Post-irradiation Fuel Cooling Time and Average Burnup Per Thoria Rod Canister:

A fuel post-irradiation cooling time 18 years and an average burnup 16,000 MWD/MTIHM.

f. Initial Heavy Metal Weight:

27 kg/canister

g. Fuel Cladding O.D.:

0.412 inches

h. Fuel Cladding I.D.:

0.362 inches

i. Fuel Pellet O.D.:

0.358 inches

j. Active Fuel Length:

111 inches

k. Canister Weight:

550 lbs, including fuel

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-16 Table 2.1-1 (page 10 of 30)

Fuel Assembly Limits II. MPC MODEL: MPC-68F (continued)

B. Quantity per MPC (up to a total of 68 assemblies):

(All fuel assemblies must be array/class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A):

Up to four (4) DFCs containing uranium oxide BWR FUEL DEBRIS or MOX BWR FUEL DEBRIS. The remaining MPC-68F fuel storage locations may be filled with fuel assemblies of the following type, as applicable:

1. Uranium oxide BWR INTACT FUEL ASSEMBLIES;
2. MOX BWR INTACT FUEL ASSEMBLIES;
3. Uranium oxide BWR DAMAGED FUEL ASSEMBLIES placed in DFCs;
4. MOX BWR DAMAGED FUEL ASSEMBLIES placed in DFCs; or
5. Up to one (1) Dresden Unit 1 Thoria Rod Canister.

C. Fuel assemblies with stainless steel channels are not authorized for loading in the MPC-68F.

D. Dresden Unit 1 fuel assemblies with one Antimony-Beryllium neutron source are authorized for loading in the MPC-68F. The Antimony-Beryllium source material shall be in a water rod location.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-17 Table 2.1-1 (page 11 of 30)

Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF A. Allowable Contents

1. Uranium oxide or MOX BWR INTACT FUEL ASSEMBLIES listed in Table 2.1-3, with or without channels and meeting the following specifications:
a. Cladding Type:

ZR or Stainless Steel (SS) as specified in Table 2.1-3 for the applicable fuel assembly array/class

b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:

As specified in Table 2.1-3 for the applicable fuel assembly array/class.

c. Initial Maximum Rod Enrichment As specified in Table 2.1-3 for the applicable fuel assembly array/class.
d. Post-irradiation Cooling Time and Average Burnup Per Assembly
i. Array/Classes 6x6A, 6x6B, 6x6C, 7x7A, and 8x8A Cooling time 18 years and an average burnup 30,000 MWD/MTU (or MWD/MTIHM).

ii. Array/Class 8x8F Cooling time 10 years and an average burnup 27,500 MWD/MTU.

iii. Array/Classes 10x10D and 10x10E Cooling time 10 years and an average burnup 22,500 MWD/MTU.

iv. All Other Array/Classes As specified in Section 2.4.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-18 Table 2.1-1 (page 12 of 30)

Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)

A. Allowable Contents (continued)

e. Decay Heat Per Assembly
i. Array/Classes 6x6A, 6X6B, 6x6C, 7x7A, and 8x8A 115 Watts ii. Array/Class 8x8F 183.5 Watts iii. Array/Classes 10x10D and 10x10E 95 Watts iv. All Other Array/Classes As specified in Section 2.4.
f. Fuel Assembly Length
i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 135.0 inches (nominal design) ii. All Other Array/Classes 176.5 inches (nominal design)
g. Fuel Assembly Width
i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 4.70 inches (nominal design) ii. All Other Array/Classes 5.85 inches (nominal design)
h. Fuel Assembly Weight
i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 400 lbs, including channels ii. All Other Array/Classes 730 lbs, including channels

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-19 Table 2.1-1 (page 13 of 30)

Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)

A. Allowable Contents (continued)

2. Uranium oxide or MOX BWR DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, with or without channels, placed in DAMAGED FUEL CONTAINERS.

Uranium oxide and MOX BWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS shall meet the criteria specified in Table 2.1-3, and meet the following specifications:

a. Cladding Type:

ZR or Stainless Steel (SS) in accordance with Table 2.1-3 for the applicable fuel assembly array/class.

b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:
i. Array/Classes 6x6A, 6x6B, 6x6C, 7x7A, and 8x8A.

As specified in Table 2.1-3 for the applicable fuel assembly array/class.

ii. All Other Array Classes 4.0 wt.% 235U.

c. Initial Maximum Rod Enrichment As specified in Table 2.1-3 for the applicable fuel assembly array/class.
d. Post-irradiation Cooling Time and Average Burnup Per Assembly:
i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A Cooling time 18 years and an average burnup 30,000 MWD/MTU (or MWD/MTIHM).

ii. Array/Class 8x8F Cooling time 10 years and an average burnup 27,500 MWD/MTU.

iii. Array/Class 10x10D and 10x10E Cooling time 10 years and an average burnup 22,500 MWD/MTU.

iv. All Other Array/Classes As specified in Section 2.4.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-20 Table 2.1-1 (page 14 of 30)

Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)

A. Allowable Contents (continued)

e. Decay Heat Per Assembly
i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 115 Watts ii. Array/Class 8x8F 183.5 Watts iii. Array/Classes 10x10D and 10x10E 95 Watts iv. All Other Array/Classes As specified in Section 2.4.
f. Fuel Assembly Length
i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 135.0 inches (nominal design) ii. All Other Array/Classes 176.5 inches (nominal design)
g. Fuel Assembly Width
i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 4.70 inches (nominal design) ii. All Other Array/Classes 5.85 inches (nominal design)
h. Fuel Assembly Weight
i. Array/Class 6x6A, 6x6B, 6x6C, 7x7A, or 8x8A 550 lbs, including channels and DFC ii. All Other Array/Classes 830 lbs, including channels and DFC

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-21 Table 2.1-1 (page 15 of 30)

Fuel Assembly limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)

A. Allowable Contents (continued)

3. Thoria rods (ThO2 and UO2) placed in Dresden Unit 1 Thoria Rod Canisters and meeting the following specifications:
a. Cladding type ZR
b. Composition 98.2 wt.% ThO2, 1.8 wt.% UO2 with an enrichment of 93.5 wt.% 235U.

OR 98.5 wt.% ThO2, 1.5 wt.% UO2 with an enrichment of 93.5% wt.% 235U

c. Number of Rods per Thoria Rod Canister:

18

d. Decay Heat Per Thoria Rod Canister:

115 Watts

e. Post-irradiation Fuel Cooling Time and Average Burnup per Thoria Rod Canister:

A fuel post-irradiation cooling time 18 years and an average burnup 16,000 MWD/MTIHM

f. Initial Heavy Metal Weight:

27 kg/canister

g. Fuel Cladding O.D.:

0.412 inches

h. Fuel Cladding I.D.:

0.362 inches

i. Fuel Pellet O.D.:

0.358 inches

j. Active Fuel Length:

111 inches

k. Canister Weight:

550 lbs, including fuel

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-22 Table 2.1-1 (page 16 of 30)

Fuel Assembly Limits III. MPC MODEL: MPC-68 and MPC-68FF (continued)

B. Quantity per MPC (up to a total of 68 assemblies)

1. For fuel assembly array/classes 6x6A, 6X6B, 6x6C, 7x7A, or 8x8A, up to 68 BWR INTACT FUEL ASSEMBLIES and/or DAMAGED FUEL ASSEMBLIES.

Up to eight (8) DFCs containing FUEL DEBRIS from these array/classes may be stored.

2. For all other array/classes, up to sixteen (16) DFCs containing BWR DAMAGED FUEL ASSEMBLIES and/or up to eight (8) DFCs containing FUEL DEBRIS. DFCs shall be located only in fuel storage locations 1, 2, 3, 8, 9, 16, 25, 34, 35, 44, 53, 60, 61, 66, 67, and/or 68. The remaining fuel storage locations may be filled with fuel assemblies of the following type:
i.

Uranium Oxide BWR INTACT FUEL ASSEMBLIES; or ii.

MOX BWR INTACT FUEL ASSEMBLIES.

3. Up to one (1) Dresden Unit 1 Thoria Rod Canister C. Dresden Unit 1 fuel assemblies with one Antimony-Beryllium neutron source are authorized for loading. The Antimony-Beryllium source material shall be in a water rod location.

D. Array/Class 10x10D and 10x10E fuel assemblies in stainless steel channels must be stored in fuel storage locations 19 - 22, 28 - 31, 38 -41, and/or 47 -

50 (see Figure 2.1-4).

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-23 Table 2.1-1 (page 17 of 30)

Fuel Assembly Limits IV. MPC MODEL: MPC-24E and MPC-24EF A. Allowable Contents

1.

Uranium oxide, PWR INTACT FUEL ASSEMBLIES listed in Table 2.1-2, with or without NON-FUEL HARDWARE and meeting the following specifications (Note 1):

a. Cladding Type:

ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class

b. Initial Enrichment:

As specified in Table 2.1-2 for the applicable fuel assembly array/class.

c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
i. Array/Classes 14x14D, 14x14E, and 15x15G Cooling time 8 years and an average burnup 40,000 MWD/MTU.

ii. All Other Array/Classes As specified in Section 2.4.

iii. NON-FUEL HARDWARE As specified in Table 2.1-8.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-24 Table 2.1-1 (page 18 of 30)

Fuel Assembly Limits IV. MPC MODEL: MPC-24E and MPC-24EF (continued)

A. Allowable Contents (continued)

d. Decay Heat Per Fuel Storage Location:
i. Array/Classes 14x14D, 14x14E, and 15x15G 710 Watts.

ii. All other Array/Classes As specified in Section 2.4.

e. Fuel Assembly Length:

176.8 inches (nominal design)

f. Fuel Assembly Width:

8.54 inches (nominal design)

g. Fuel Assembly Weight:

1,720 lbs (including NON-FUEL HARDWARE) for assemblies that do not require fuel spacers, otherwise, 1,680 lbs (including NON-FUEL HARDWARE)

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-25 Table 2.1-1 (page 19 of 30)

Fuel Assembly Limits IV. MPC MODEL: MPC-24E and MPC-24EF (continued)

A. Allowable Contents (continued)

2. Uranium oxide, PWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS, with or without NON-FUEL HARDWARE, placed in DAMAGED FUEL CONTAINERS.

Uranium oxide PWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS shall meet the criteria specified in Table 2.1-2 and meet the following specifications (Note 1):

a. Cladding Type:

ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class

b. Initial Enrichment:

As specified in Table 2.1-2 for the applicable fuel assembly array/class.

c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
i. Array/Classes 14x14D, 14x14E, and 15x15G Cooling time 8 years and an average burnup 40,000 MWD/MTU.

ii. All Other Array/Classes As specified in Section 2.4.

iii. NON-FUEL HARDWARE As specified in Table 2.1-8.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-26 Table 2.1-1 (page 20 of 30)

Fuel Assembly Limits IV. MPC MODEL: MPC-24E and MPC-24EF (continued)

A. Allowable Contents (continued)

d. Decay Heat Per Fuel Storage Location:
i. Array/Classes 14x14D, 14x14E, and 15x15G 710 Watts.

ii. All Other Array/Classes As specified in Section 2.4.

e. Fuel Assembly Length 176.8 inches (nominal design)
f. Fuel Assembly Width 8.54 inches (nominal design)
g. Fuel Assembly Weight 1,720 lbs (including NON-FUEL HARDWARE and DFC) for assemblies that do not require fuel spacers, otherwise, 1,680 lbs (including NON-FUEL HARDWARE and DFC)

B. Quantity per MPC: Up to four (4) DAMAGED FUEL ASSEMBLIES and/or FUEL DEBRIS in DAMAGED FUEL CONTAINERS, stored in fuel storage locations 3, 6, 19 and/or 22. The remaining fuel storage locations may be filled with PWR INTACT FUEL ASSEMBLIES meeting the applicable specifications.

C. One NSA is permitted for loading.

Note 1: Fuel assemblies containing BPRAs, TPDs, WABAs, water displacement guide tube plugs, orifice rod assemblies, or vibration suppressor inserts, with or without ITTRs, may be stored in any fuel storage location. Fuel assemblies containing APSRs or NSAs may only be loaded in fuel storage locations 9, 10, 15, and/or 16 (see Figure 2.1-2). Fuel assemblies containing CRAs, RCCAs, or CEAs may only be stored in fuel storage locations 4, 5, 8 - 11, 14 - 17, 20 and/or 21 (see Figure 2.1-2). These requirements are in addition to any other requirements specified for uniform or regionalized fuel loading.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-27 Table 2.1-1 (page 21 of 30)

Fuel Assembly Limits V. MPC MODEL: MPC-32 and MPC-32F A. Allowable Contents

1.

Uranium oxide, PWR INTACT FUEL ASSEMBLIES listed in Table 2.1-2, with or without NON-FUEL HARDWARE and meeting the following specifications (Note 1):

a. Cladding Type:

ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class

b. Initial Enrichment:

As specified in Table 2.1-2 for the applicable fuel assembly array/class.

c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
i. Array/Classes 14x14D, 14x14E, and 15x15G Cooling time 9 years and an average burnup 30,000 MWD/MTU or cooling time 20 years and an average burnup 40,000 MWD/MTU.

ii. All Other Array/Classes As specified in Section 2.4.

iii. NON-FUEL HARDWARE As specified in Table 2.1-8.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-28 Table 2.1-1 (page 22 of 30)

Fuel Assembly Limits V. MPC MODEL: MPC-32 and MPC-32F (contd)

A. Allowable Contents (contd)

d. Decay Heat Per Fuel Storage Location:
i. Array/Classes 14x14D, 14x14E, and 15x15G 500 Watts.

ii. All Other Array/Classes As specified in Section 2.4.

e. Fuel Assembly Length 176.8 inches (nominal design)
f. Fuel Assembly Width 8.54 inches (nominal design)
g. Fuel Assembly Weight 1,720 lbs (including NON-FUEL HARDWARE) for assemblies that do not require fuel spacers, otherwise, 1,680 lbs (including NON-FUEL HARDWARE)

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-29 Table 2.1-1 (page 23 of 30)

Fuel Assembly Limits V. MPC MODEL: MPC-32 and MPC-32F (contd)

A. Allowable Contents (contd)

2.

Uranium oxide, PWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS, with or without NON-FUEL HARDWARE, placed in DAMAGED FUEL CONTAINERS. Uranium oxide PWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS shall meet the criteria specified in Table 2.1-2 and meet the following specifications (Note 1):

a. Cladding Type:

ZR or Stainless Steel (SS) as specified in Table 2.1-2 for the applicable fuel assembly array/class

b. Initial Enrichment:

As specified in Table 2.1-2 for the applicable fuel assembly array/class.

c. Post-irradiation Cooling Time and Average Burnup Per Assembly:
i. Array/Classes 14x14D, 14x14E, and 15x15G Cooling time 9 years and an average burnup 30,000 MWD/MTU or cooling time 20 years and an average burnup 40,000 MWD/MTU.

ii. All Other Array/Classes As specified in Section 2.4.

iii. NON-FUEL HARDWARE As specified in Table 2.1-8.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-30 Table 2.1-1 (page 24 of 30)

Fuel Assembly Limits V. MPC MODEL: MPC-32 and MPC-32F (contd)

A. Allowable Contents (contd)

d. Decay Heat Per Fuel Storage Location:
i. Array/Classes 14x14D, 14x14E, and 15x15G 500 Watts.

ii. All Other Array/Classes As specified in Section 2.4.

e. Fuel Assembly Length 176.8 inches (nominal design)
f. Fuel Assembly Width 8.54 inches (nominal design)
g. Fuel Assembly Weight 1,720 lbs (including NON-FUEL HARDWARE and DFC) for assemblies that do not require fuel spacers, otherwise, 1,680 lbs (including NON-FUEL HARDWARE and DFC)

B. Quantity per MPC: Up to eight (8) DAMAGED FUEL ASSEMBLIES and/or FUEL DEBRIS in DAMAGED FUEL CONTAINERS, stored in fuel storage locations 1, 4, 5, 10, 23, 28, 29, and/or 32. The remaining fuel storage locations may be filled with PWR INTACT FUEL ASSEMBLIES meeting the applicable specifications.

C.

One NSA is permitted for loading.

Note 1: Fuel assemblies containing BPRAs, TPDs, WABAs, water displacement guide tube plugs, orifice rod assemblies, or vibration suppressor inserts, with or without ITTRs, may be stored in any fuel storage location. Fuel assemblies containing NSAs may only be loaded in fuel storage locations 13, 14, 19 and/or 20 (see Figure 2.1-3). Fuel assemblies containing CRAs, RCCAs, CEAs or APSRs may only be loaded in fuel storage locations 7, 8, 12-15, 18-21, 25 and/or 26 (see Figure 2.1-3). These requirements are in addition to any other requirements specified for uniform or regionalized fuel loading.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-31 Table 2.1-1 (page 25 of 30)

Fuel Assembly Limits VI. MPC MODEL: MPC-68M A. Allowable Contents

1. Uranium oxide BWR UNDAMAGED FUEL ASSEMBLIES listed in Table 2.1-3, with or without channels and meeting the following specifications:
a. Cladding Type:

ZR

b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:

As specified in Table 2.1-3 for the applicable fuel assembly array/class.

c. Initial Maximum Rod Enrichment As specified in Table 2.1-3 for the applicable fuel assembly array/class.
d. Post-irradiation Cooling Time and Average Burnup Per Assembly
i. Array/Class 8x8F Cooling time 10 years and an average burnup 27,500 MWD/MTU.

ii. All Other Array/Classes As specified in Section 2.4.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-32 Table 2.1-1 (page 26 of 30)

Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)

A. Allowable Contents (continued)

e. Decay Heat Per Assembly
i. Array/Class 8x8F 183.5 Watts ii. All Other Array/Classes As specified in Section 2.4.
f. Fuel Assembly Length 176.5 inches (nominal design)
g. Fuel Assembly Width 5.85 inches (nominal design)
h. Fuel Assembly Weight 730 lbs, including channels

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-33 Table 2.1-1 (page 27 of 30)

Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)

A. Allowable Contents (continued)

2. Uranium oxide BWR DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, with or without channels, placed in DAMAGED FUEL CONTAINERS. Uranium oxide BWR DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS shall meet the criteria specified in Table 2.1-3, and meet the following specifications:
a. Cladding Type:

ZR

b. Maximum PLANAR-AVERAGE INITIAL ENRICHMENT:

As specified in Table 2.1-3 for the applicable fuel assembly array/class.

c. Initial Maximum Rod Enrichment As specified in Table 2.1-3 for the applicable fuel assembly array/class.
d. Post-irradiation Cooling Time and Average Burnup Per Assembly:
i. Array/Class 8x8F Cooling time 10 years and an average burnup 27,500 MWD/MTU.

ii. All Other Array/Classes As specified in Section 2.4.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-34 Table 2.1-1 (page 28 of 30)

Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)

A. Allowable Contents (continued)

e. Decay Heat Per Assembly
i. Array/Class 8x8F 183.5 Watts ii. All Other Array/Classes As specified in Section 2.4.
f. Fuel Assembly Length 176.5 inches (nominal design)
g. Fuel Assembly Width 5.85 inches (nominal design)
h. Fuel Assembly Weight 830 lbs, including channels and DFC

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-35 Table 2.1-1 (page 29 of 30)

Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)

A. Allowable Contents (continued)

3. Thoria rods (ThO2 and UO2) placed in Dresden Unit 1 Thoria Rod Canisters and meeting the following specifications:
a. Cladding Type:

ZR

b. Composition 98.2 wt.% ThO2, 1.8 wt.% UO2 with an enrichment of 93.5 wt.%

235U OR 98.5 wt.% ThO2, 1.5 wt.% UO2 with an enrichment of 93.5% wt.%

235U

c. Number of Rods per Thoria Rod Canister:

18

d. Decay Heat Per Thoria Rod Canister:

115 Watts

e. Post-irradiation Fuel Cooling Time and Average Burnup per Thoria Rod Canister:

A fuel post-irradiation cooling time 18 years and an average burnup 16,000 MWD/MTIHM

f. Initial Heavy Metal Weight:

27 kg/canister

g. Fuel Cladding O.D.:

0.412 inches

h. Fuel Cladding I.D.:

0.362 inches

i. Fuel Pellet O.D.:

0.358 inches

j. Active Fuel Length:

111 inches

k. Canister Weight:

550 lbs, including fuel

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-36 Table 2.1-1 (page 30 of 30)

Fuel Assembly Limits VI. MPC MODEL: MPC-68M (continued)

B. Quantity per MPC (up to a total of 68 assemblies)

1. Up to sixteen (16) DFCs containing BWR DAMAGED FUEL ASSEMBLIES and/or up to eight (8) DFCs containing FUEL DEBRIS. DFCs shall be located only in fuel storage locations 1, 2, 3, 8, 9, 16, 25, 34, 35, 44, 53, 60, 61, 66, 67, and/or 68. The remaining fuel storage locations may be filled with Uranium Oxide BWR UNDAMAGED FUEL ASSEMBLIES.
2. Up to one (1) Dresden Unit 1 Thoria Rod Canister.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-37 Table 2.1-2 (page 1 of 5)

PWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)

Fuel Assembly Array/Class 14x14A 14x14B 14x14C 14x14D 14x14E Clad Material ZR ZR ZR SS SS Design Initial U (kg/assy.) (Note 3) 365 412 438 400 206 Initial Enrichment (MPC-24, 24E and 24EF without soluble boron credit) (wt % 235U)

(Note 7) 4.6 (24) 5.0 (24E/24EF) 4.6 (24) 5.0 (24E/24EF) 4.6 (24) 5.0 (24E/24EF) 4.0 (24) 5.0 (24E/24EF) 5.0 (24) 5.0 (24E/24EF)

Initial Enrichment (MPC-24, 24E, 24EF, 32, or 32F with soluble boron credit - see Note 5)

(wt % 235U) 5.0 5.0 5.0 5.0 5.0 No. of Fuel Rod Locations (Note 11) 179 179 176 180 173 Fuel Rod Clad O.D. (in.)

0.400 0.417 0.440 0.422 0.3415 Fuel Rod Clad I.D.

(in.)

0.3514 0.3734 0.3880 0.3890 0.3175 Fuel Pellet Dia.

(in.)(Note 8) 0.3444 0.3659 0.3805 0.3835 0.3130 Fuel Rod Pitch (in.)

0.556 0.556 0.580 0.556 Note 6 Active Fuel Length (in.)

150 150 150 144 102 No. of Guide and/or Instrument Tubes 17 17 5 (Note 4) 16 0

Guide/Instrument Tube Thickness (in.)

0.017 0.017 0.038 0.0145 N/A

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-38 Table 2.1-2 (page 2 of 5)

PWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)

Fuel Assembly Array/Class 15x15A 15x15B 15x15C 15x15D 15x15E 15x15F Clad Material ZR ZR ZR ZR ZR ZR Design Initial U (kg/assy.) (Note 3)

< 473

< 473

< 473

< 495

< 495

< 495 Initial Enrichment (MPC-24, 24E and 24EF without soluble boron credit)

(wt % 235U)

(Note 7)

< 4.1 (24)

< 4.5 (24E/24EF)

< 4.1 (24)

< 4.5 (24E/24EF)

< 4.1 (24)

< 4.5 (24E/24EF)

< 4.1 (24)

< 4.5 (24E/24EF)

< 4.1 (24)

< 4.5 (24E/24EF)

< 4.1 (24)

< 4.5 (24E/24EF)

Initial Enrichment (MPC-24, 24E, 24EF, 32, or 32F with soluble boron credit - see Note 5)(wt % 235U)

< 5.0

< 5.0

< 5.0

< 5.0

< 5.0

< 5.0 No. of Fuel Rod Locations (Note 11) 204 204 204 208 208 208 Fuel Rod Clad O.D. (in.)

> 0.418

> 0.420

> 0.417

> 0.430

> 0.428

> 0.428 Fuel Rod Clad I.D.

(in.)

< 0.3660

< 0.3736

< 0.3640

< 0.3800

< 0.3790

< 0.3820 Fuel Pellet Dia.

(in.) (Note 8)

< 0.3580

< 0.3671

< 0.3570

< 0.3735

< 0.3707

< 0.3742 Fuel Rod Pitch (in.)

< 0.550

< 0.563

< 0.563

< 0.568

< 0.568

< 0.568 Active Fuel Length (in.)

< 150

< 150

< 150

< 150

< 150

< 150 No. of Guide and/or Instrument Tubes 21 21 21 17 17 17 Guide/Instrument Tube Thickness (in.)

> 0.0165

> 0.015

> 0.0165

> 0.0150

> 0.0140

> 0.0140

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-39 Table 2.1-2 (page 3 of 5)

PWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)

Fuel Assembly Array/ Class 15x15G 15x15H 15x15I 16x16A 16x16B 16x16C Clad Material SS ZR ZR ZR ZR ZR Design Initial U (kg/assy.)(Note 3)

< 420

< 495 495

< 448

< 427

< 426 Initial Enrichment (MPC-24, 24E, and 24EF without soluble boron credit)(wt % 235U)

(Note 7)

< 4.0 (24)

< 4.5 (24E/24 EF)

< 3.8 (24)

< 4.2 (24E/24E F)

N/A (Note 9)

< 4.6 (24)

< 5.0 (24E/24E F)

< 4.6 (24)

< 5.0 (24E/24E F)

< 4.6 (24)

< 5.0 (24E/24E F)

Initial Enrichment (MPC-24, 24E, 24EF, 32, or 32F with soluble boron credit - see Note 5) (wt %

235U)

< 5.0

< 5.0 5.0 (Note 9)

< 5.0

< 5.0

< 5.0 No. of Fuel Rod Locations (Note 11) 204 208 216 236 236 235 Fuel Rod Clad O.D. (in.)

> 0.422

> 0.414 0.413

> 0.382

> 0.374

> 0.374 Fuel Rod Clad I.D. (in.)

0.3890

< 0.3700 0.367

< 0.3350

< 0.3290

< 0.3290 Fuel Pellet Dia.

(in.) (Note 8) 0.3825

< 0.3622 0.360

< 0.3255

< 0.3225

< 0.3225 Fuel Rod Pitch (in.)

< 0.563

< 0.568 0.550

< 0.506

< 0.506

< 0.485 Active Fuel Length (in.)

< 144

< 150 150

< 150

< 150

< 150 No. of Guide and/or Instrument Tubes 21 17 9

(Note 10) 5 (Note 4) 5 (Note 4) 21 Guide/Instrument Tube Thickness (in.)

0.0145

> 0.0140 0.0140

> 0.0350

> 0.0400

> 0.0157

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-40 Table 2.1-2 (page 4 of 5)

PWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)

Fuel Assembly Array/ Class 17x17A 17x17B 17x17C Clad Material ZR ZR ZR Design Initial U (kg/assy.)(Note

3)

< 433

< 474

< 480 Initial Enrichment (MPC-24, 24E, and 24EF without soluble boron credit)(wt % 235U) (Note

7)

< 4.0 (24)

< 4.4 (24E/24EF)

< 4.0 (24)

< 4.4 (24E/24EF)

< 4.0 (24)

< 4.4 (24E/24EF)

Initial Enrichment (MPC-24, 24E, 24EF, 32, or 32F with soluble boron credit - see Note

5) (wt % 235U)

< 5.0

< 5.0

< 5.0 No. of Fuel Rod Locations (Note 11) 264 264 264 Fuel Rod Clad O.D. (in.)

> 0.360

> 0.372

> 0.377 Fuel Rod Clad I.D. (in.)

< 0.3150

< 0.3310

< 0.3330 Fuel Pellet Dia. (in.) (Note 8)

< 0.3088

< 0.3232

< 0.3252 Fuel Rod Pitch (in.)

< 0.496

< 0.496

< 0.502 Active Fuel Length (in.)

< 150

< 150

< 150 No. of Guide and/or Instrument Tubes 25 25 25 Guide/Instrument Tube Thickness (in.)

> 0.016

> 0.014

> 0.020

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-41 Table 2.1-2 (page 5 of 5)

PWR FUEL ASSEMBLY CHARACTERISTICS Notes:

1. All dimensions are design nominal values. Maximum and minimum dimensions are specified to bound variations in design nominal values among fuel assemblies within a given array/class.
2. Deleted.
3. Design initial uranium weight is the nominal uranium weight specified for each assembly by the fuel manufacturer or reactor user. For each PWR fuel assembly, the total uranium weight limit specified in this table may be increased up to 2.0 percent for comparison with users fuel records.
4. Each guide tube replaces four fuel rods.
5. Soluble boron concentration per LCO 3.3.1.
6. This fuel assembly array/class includes only the Indian Point Unit 1 fuel assembly.

This fuel assembly has two pitches in different sectors of the assembly. These pitches are 0.441 inches and 0.453 inches.

7. For those MPCs loaded with both INTACT FUEL ASSEMBLIES and DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, the maximum initial enrichment of the INTACT FUEL ASSEMBLIES, DAMAGED FUEL ASSEMBLIES and FUEL DEBRIS is 4.0 wt.% 235U.
8. Annular fuel pellets are allowed in the top and bottom 12" of the active fuel length.
9. This fuel assembly array/class can only be loaded in MPC-32.
10. One Instrument Tube and eight Guide Bars (Solid ZR).
11. Any number of fuel rods in an assembly can be replaced by irradiated or unirradiated Steel or Zirconia rods. If the rods are irradiated, the site specific dose and dose rate analyses performed under 10 CFR 72.212 should include considerations for the presence of such rods.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-42 Table 2.1-3 (page 1 of 6)

BWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)

Fuel Assembly Array/Class 6x6A 6x6B 6x6C 7x7A 7x7B 8x8A Clad Material ZR ZR ZR ZR ZR ZR Design Initial U (kg/assy.) (Note 3)

< 110

< 110

< 110

< 100

< 198

< 120 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68, 68F, and 68FF)

(wt.% 235U)

(Note 14)

< 2.7

< 2.7 for the UO2 rods.

See Note 4 for MOX rods

< 2.7

< 2.7

< 4.2

< 2.7 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68M)

(wt.% 235U)

(Note 16, 19)

Note 18 Note 18 Note 18 Note 18 4.8 Note 18 Initial Maximum Rod Enrichment (wt.% 235U)

< 4.0

< 4.0

< 4.0

< 5.5

< 5.0

< 4.0 No. of Fuel Rod Locations (Note 20) 35 or 36 35 or 36 (up to 9 MOX rods) 36 49 49 63 or 64 Fuel Rod Clad O.D.

(in.)

> 0.5550

> 0.5625

> 0.5630

> 0.4860

> 0.5630

> 0.4120 Fuel Rod Clad I.D.

(in.)

< 0.5105

< 0.4945

< 0.4990

< 0.4204

< 0.4990

< 0.3620 Fuel Pellet Dia. (in.)

< 0.4980

< 0.4820

< 0.4880

< 0.4110

< 0.4910

< 0.3580 Fuel Rod Pitch (in.)

< 0.710

< 0.710

< 0.740

< 0.631

< 0.738

< 0.523 Active Fuel Length (in.)

< 120

< 120

< 77.5

< 80

< 150

< 120 No. of Water Rods (Note 11) 1 or 0 1 or 0 0

0 0

1 or 0 Water Rod Thickness (in.)

> 0

> 0 N/A N/A N/A

> 0 Channel Thickness (in.)

< 0.060

< 0.060

< 0.060

< 0.060

< 0.120

< 0.100

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-43 Table 2.1-3 (2 of 6)

BWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)

Fuel Assembly Array/Class 8x8B 8x8C 8x8D 8x8E 8x8F 9x9A Clad Material ZR ZR ZR ZR ZR ZR Design Initial U (kg/assy.) (Note 3)

< 192

< 190

< 190

< 190

< 191

< 180 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68, 68F, and 68FF)

(wt.% 235U)

(Note 14)

< 4.2

< 4.2

< 4.2

< 4.2

< 4.0

< 4.2 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68M)

(wt.% 235U)

(Note 16, 19) 4.8 4.8 4.8 4.8 4.5 (Note 15) 4.8 Initial Maximum Rod Enrichment (wt.% 235U)

< 5.0

< 5.0

< 5.0

< 5.0

< 5.0

< 5.0 No. of Fuel Rod Locations (Note 20) 63 or 64 62 60 or 61 59 64 74/66 (Note 5)

Fuel Rod Clad O.D.

(in.)

> 0.4840

> 0.4830

> 0.4830

> 0.4930

> 0.4576

> 0.4400 Fuel Rod Clad I.D.

(in.)

< 0.4295

< 0.4250

< 0.4230

< 0.4250

< 0.3996

< 0.3840 Fuel Pellet Dia. (in.)

< 0.4195

< 0.4160

< 0.4140

< 0.4160

< 0.3913

< 0.3760 Fuel Rod Pitch (in.)

< 0.642

< 0.641

< 0.640

< 0.640

< 0.609

< 0.566 Design Active Fuel Length (in.)

< 150

< 150

< 150

< 150

< 150

< 150 No. of Water Rods (Note 11) 1 or 0 2

1 - 4 (Note 7) 5 N/A (Note 12) 2 Water Rod Thickness (in.)

> 0.034

> 0.00

> 0.00

> 0.034

> 0.0315

> 0.00 Channel Thickness (in.)

< 0.120

< 0.120

< 0.120

< 0.100

< 0.055

< 0.120

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-44 Table 2.1-3 (page 3 of 6)

BWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)

Fuel Assembly Array/Class 9x9B 9x9C 9x9D 9x9E (Note 13) 9x9F (Note 13) 9x9G Clad Material ZR ZR ZR ZR ZR ZR Design Initial U (kg/assy.)(Note 3)

< 180

< 182

< 182

< 183

< 183

< 164 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68, 68F, and 68FF)

(wt.% 235U)

(Note 14)

< 4.2

< 4.2

< 4.2

< 4.0

< 4.0

< 4.2 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68M)

(wt.% 235U)

(Note 16, 19) 4.8 4.8 4.8 4.5 (Note 15) 4.5 (Note 15) 4.8 Initial Maximum Rod Enrichment (wt.% 235U)

< 5.0

< 5.0

< 5.0

< 5.0

< 5.0

< 5.0 No. of Fuel Rod Locations (Note 20) 72 80 79 76 76 72 Fuel Rod Clad O.D.

(in.)

> 0.4330

> 0.4230

> 0.4240

> 0.4170

> 0.4430

> 0.4240 Fuel Rod Clad I.D.

(in.)

< 0.3810

< 0.3640

< 0.3640

< 0.3640

< 0.3860

< 0.3640 Fuel Pellet Dia. (in.)

< 0.3740

< 0.3565

< 0.3565

< 0.3530

< 0.3745

< 0.3565 Fuel Rod Pitch (in.)

< 0.572

< 0.572

< 0.572

< 0.572

< 0.572

< 0.572 Design Active Fuel Length (in.)

< 150

< 150

< 150

< 150

< 150

< 150 No. of Water Rods (Note 11) 1 (Note 6) 1 2

5 5

1 (Note 6)

Water Rod Thickness (in.)

> 0.00

> 0.020

> 0.0300

> 0.0120

> 0.0120

> 0.0320 Channel Thickness (in.)

< 0.120

< 0.100

< 0.100

< 0.120

< 0.120

< 0.120

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-45 Table 2.1-3 (page 4 of 6)

BWR FUEL ASSEMBLY CHARACTERISTICS (Note 1)

Fuel Assembly Array/Class 10x10A 10x10B 10x10C 10x10D 10x10E 10x10F 10x10G Clad Material ZR ZR ZR SS SS ZR ZR Design Initial U (kg/assy.)

(Note 3)

< 188

< 188

< 179

< 125

< 125 192 188 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT(MPC-68, 68F, and 68FF)

(wt.% 235U) (Note 14)

< 4.2

< 4.2

< 4.2

< 4.0

< 4.0 Note 17 Note 17 Maximum PLANAR-AVERAGE INITIAL ENRICHMENT (MPC-68M)

(wt.% 235U)

(Note 16, 19) 4.8 4.8 4.8 Note 18 Note 18 4.7 (Note 15) 4.75 (Note 15)

Initial Maximum Rod Enrichment (wt.% 235U)

< 5.0

< 5.0

< 5.0

< 5.0

< 5.0

< 5.0

< 5.0 No. of Fuel Rod Locations (Note 20) 92/78 (Note 8) 91/83 (Note 9) 96 100 96 92/78 (Note 8) 96/84 Fuel Rod Clad O.D.

(in.)

0.4040 0.3957

> 0.3780 0.3960 0.3940 0.4035 0.387 Fuel Rod Clad I.D. (in.)

0.3520 0.3480

< 0.3294 0.3560 0.3500 0.3570 0.340 Fuel Pellet Dia. (in.)

0.3455 0.3420

< 0.3224 0.3500 0.3430 0.3500 0.334 Fuel Rod Pitch (in.)

< 0.510

< 0.510

< 0.488

< 0.565

< 0.557 0.510 0.512 Design Active Fuel Length (in.)

< 150

< 150

< 150

< 83

< 83 150 150 No. of Water Rods (Note 11) 2 1

(Note 6) 5 (Note 10) 0 4

2 5

(Note 10)

Water Rod Thickness (in.)

> 0.030

> 0.00

> 0.031 N/A

> 0.022 0.030 0.031 Channel Thickness (in.)

< 0.120

< 0.120

< 0.055

< 0.080

< 0.080 0.120 0.060

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-46 Table 2.1-3 (page 5 of 6)

BWR FUEL ASSEMBLY CHARACTERISTICS Notes:

1.

All dimensions are design nominal values. Maximum and minimum dimensions are specified to bound variations in design nominal values among fuel assemblies within a given array/class.

2.

Deleted.

3.

Design initial uranium weight is the nominal uranium weight specified for each assembly by the fuel manufacturer or reactor user. For each BWR fuel assembly, the total uranium weight limit specified in this table may be increased up to 1.5 percent for comparison with users fuel records.

4.

0.635 wt. % 235U and 1.578 wt. % total fissile plutonium (239Pu and 241Pu),

(wt. % of total fuel weight, i.e., UO2 plus PuO2).

5.

This assembly class contains 74 total rods; 66 full length rods and 8 partial length rods.

6.

Square, replacing nine fuel rods.

7.

Variable.

8.

This assembly contains 92 total fuel rods; 78 full length rods and 14 partial length rods.

9.

This assembly class contains 91 total fuel rods; 83 full length rods and 8 partial length rods.

10. One diamond-shaped water rod replacing the four center fuel rods and four rectangular water rods dividing the assembly into four quadrants.
11. These rods may also be sealed at both ends and contain Zr material in lieu of water.
12. This assembly is known as QUAD+. It has four rectangular water cross segments dividing the assembly into four quadrants.
13. For the SPC 9x9-5 fuel assembly, each fuel rod must meet either the 9x9E or the 9x9F set of limits for clad O.D., clad I.D., and pellet diameter.
14. For MPC-68, 68F, and 68FF loaded with both INTACT FUEL ASSEMBLIES and DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, the maximum PLANAR AVERAGE INITIAL ENRICHMENT for the INTACT FUEL ASSEMBLIES is limited to 3.7 wt.% 235U, as applicable.
15. Fuel assemblies classified as damaged fuel assemblies are limited to 4.6 wt.%

235U for the 10x10F and 10x10G arrays/classes and 4.0 wt.% 235U for the 8x8F, 9x9E and 9x9F arrays/classes.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-47 Table 2.1-3 (page 6 of 6)

BWR FUEL ASSEMBLY CHARACTERISTICS

16. For MPC-68M loaded with both UNDAMAGED FUEL ASSEMBLIES and DAMAGED FUEL ASSEMBLIES or FUEL DEBRIS, the maximum PLANAR AVERAGE INITIAL ENRICHMENT for the UNDAMAGED FUEL ASSEMBLIES is limited to the enrichment limit of the damaged assembly.
17. This fuel assembly array/class is not allowable contents in MPC-68, 68F, or 68FF.
18. This fuel assembly array/class is not allowable contents in MPC-68M.
19. In accordance with the definition of UNDAMAGED FUEL ASSEMBLY, certain assemblies may be limited to up to 3.3 wt.% U-235. When loading these fuel assemblies, all other undamaged fuel assemblies in the MPC are limited to enrichments as specified in this table.
20. Any number of fuel rods in an assembly can be replaced by irradiated or unirradiated Steel or Zirconia rods. If the rods are irradiated, the site specific dose and dose rate analyses performed under 10 CFR 72.212 should include considerations for the presence of such rods.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-48

12. Table 2.1-8 NON-FUEL HARDWARE COOLING AND AVERAGE BURNUP (Notes 1, 2, 3, and 7)

Notes: 1. Burnups for NON-FUEL HARDWARE are to be determined based on the burnup and uranium mass of the fuel assemblies in which the component was inserted during reactor operation.

2. Linear interpolation between points is permitted, except that APSR burnups > 180,000 MWD/MTU and < 630,000 MWD/MTU must be cooled > 11 years.
3. Applicable to uniform loading and regionalized loading.
4. Includes Burnable Poison Rod Assemblies (BPRAs), Wet Annular Burnable Absorbers (WABAs), vibration suppressor inserts and Neutron Source Assemblies (NSAs) in combination with other control components (i.e. BPRAs, TPDs, and/or RCCAs).
5. Includes Thimble Plug Devices (TPDs), water displacement guide tube plugs, orifice rod assemblies, Control Rod Assemblies (CRAs), Control Element Assemblies (CEAs), Rod Cluster Control Assemblies (RCCAs) and NSAs without other forms of control components.
6. NA means not authorized for loading at this cooling time.
7. Non-fuel hardware burnup and cooling times are not applicable to ITTRs since they are installed post irradiation.

Post-irradiation Cooling Time (years)

NSA with NFH INSERTS (Note 4)

BURNUP (MWD/MTU)

NSA without NFH, GUIDE TUBE HARDWARE, or CONTROL COMPONENT (Note 5)

BURNUP (MWD/MTU)

APSR BURNUP (MWD/MTU) 3 24,635 NA (Note 6)

NA 4

30,000 NA NA 5

36,748 630,000 45,000 6

44,102 54,500 7

52,900 68,000 8

60,000 83,000 9

79,784 111,000 10 101,826 180,000 11 141,982 630,000 12 360,000

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-49 2.4 Decay Heat, Burnup, and Cooling Time Limits for ZR-Clad Fuel This section provides the limits on ZR-clad fuel assembly decay heat, burnup, and cooling time for storage in the HI-STORM 100 System. The method to calculate the limits and verify compliance, including examples, is provided in Chapter 12 of the HI-STORM 100 FSAR.

2.4.1 Uniform Fuel Loading Decay Heat Limits for ZR-clad fuel Table 2.4-1 provides the maximum allowable decay heat per fuel storage location for ZR-clad fuel in uniform fuel loading for each MPC model.

Table 2.4-1 Maximum Allowable Decay Heat per Fuel Storage Location (Uniform Loading, ZR-Clad)

MPC Model Decay Heat per Fuel Storage Location (kW)

Intact or Undamaged Fuel Assemblies Damaged Fuel Assemblies and Fuel Debris MPC-24

< 1.416 Not Permitted MPC-24E/24EF

< 1.416

< 1.114 MPC-32/32F

< 1.062

< 0.718 MPC-68/68FF/68M

< 0.500

< 0.393

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-50 2.4.2 Regionalized Fuel Loading Decay Heat Limits for ZR-Clad Fuel (Intact or Undamaged Fuel only)

The maximum allowable decay heat per fuel storage location for intact fuel assemblies in regionalized loading is determined using the following equations:

Q(X) = 2 x Q0 / (1 + Xy) y = 0.23 / X0.1 q2 = Q(X) / (n1 x X +n2) q1 = q2 x X Where:

Q0 = Maximum uniform storage MPC decay heat (34 kW)

X = Inner region to outer region assembly decay heat ratio (0.5 X 3) n1 = Number of storage locations in inner region from Table 2.4-2.

n2 = Number of storage locations in outer region from Table 2.4-2.

Allowable heat loads for Damaged Fuel and Fuel Debris in regionalized loading are shown in Table 2.4-5.

An optional regionalized loading pattern for MPC-68M is shown in Figure 2.4-1.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-51 Table 2.4-2 Fuel Storage Regions per MPC MPC Model Number of Storage Locations in Inner Region (Region 1)

Number of Storage Locations in Outer Region (Region 2)

MPC-24 and MPC-24E/EF 12 12 MPC-32/32F 12 20 MPC-68/68FF/68MNote1 32 36 Note 1: For an optional regionalized loading pattern for MPC-68M, see Figure 2.4-1.

Table 2.4-5 Allowable Heat Load for Damaged Fuel Assemblies and Fuel Debris under Regionalized Loading MPC Model Maximum Per Cell Allowable Heat Load for Damaged Fuel Assemblies and Fuel Debris Note 1 MPC-24E/24EF 0.75*q2 MPC-32/32F 0.65*q2 MPC-68/68FF/68MNote 2 0.75*q2 Note 1: q2 is the maximum permissible heat load in Region 2 for intact fuel assemblies.

Note 2: An optional regionalized loading pattern for MPC-68M including Damaged Fuel and Fuel Debris is shown in Figure 2.4-1

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-52 2.4.3 Burnup Limits as a Function of Cooling Time for ZR-Clad Fuel The maximum allowable fuel assembly average burnup varies with the following parameters:

  • Minimum fuel assembly cooling time
  • Maximum fuel assembly decay heat
  • Minimum fuel assembly average enrichment The maximum allowable ZR-clad fuel assembly average burnup for a given MINIMUM ENRICHMENT is calculated as described below for minimum cooling times between 2 and 40 years using the maximum permissible decay heat determined in Section 2.4.1 or 2.4.2. Different fuel assembly average burnup limits may be calculated for different minimum enrichments (by individual fuel assembly) for use in choosing the fuel assemblies to be loaded into a given MPC.

2.4.3.1 Choose a fuel assembly minimum enrichment, E235.

2.4.3.2 Calculate the maximum allowable fuel assembly average burnup for a minimum cooling time between 2 and 40 years using the equation below.

Bu = (A x q) + (B x q2) + (C x q3) + [D x (E235)2] + (E x q x E235) + (F x q2 x E235) + G Where:

Bu = Maximum allowable average burnup per fuel assembly (MWD/MTU) q =

Maximum allowable decay heat per fuel storage location determined in Section 2.4.1 or 2.4.2 (kW)

E235 =Minimum fuel assembly average enrichment (wt. % 235U)

(e.g., for 4.05 wt.%, use 4.05)

A through G = Coefficients from Tables 2.4-3 and 2.4-4 for the applicable fuel assembly array/class and minimum cooling time 2.4.3.3 Calculated burnup limits shall be rounded down to the nearest integer.

2.4.3.4 Calculated burnup limits greater than 68,200 MWD/MTU for PWR fuel and 65,000 MWD/MTU for BWR must be reduced to be equal to these values.

2.4.3.5 Linear interpolation of calculated burnups between cooling times for a given fuel assembly maximum decay heat and minimum enrichment is permitted. For example, the allowable burnup for a cooling time of 4.5 years may be interpolated between those burnups calculated for 4 year and 5 years.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-53 2.4.3.6 Each ZR-clad fuel assembly to be stored must have a MINIMUM ENRICHMENT greater than or equal to the value used in Step 2.4.3.2.

2.4.4 When complying with the maximum fuel storage location decay heat limits, users must account for the decay heat from both the fuel assembly and any NON-FUEL HARDWARE, as applicable for the particular fuel storage location, to ensure the decay heat emitted by all contents in a storage location does not exceed the limit.

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-54 Table 2.4-3 (Page 1 of 8)

PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 14x14A A

B C

D E

F G

2.0 8716.89 1454.67

-91.96

-168.45 2047.50

-209.91

-738.51 2.25 10917.50 1441.49

-112.76

-162.14 2274.96

-266.46

-788.45 2.5 13452.90 1258.44

-119.69

-154.08 2491.83

-329.35

-760.18 2.75 16326.90 847.56

-100.72

-146.46 2680.07

-390.55

-727.50 3.0 19310.30 276.56

-59.30

-139.52 2851.81

-452.00

-614.85 4.0 33007.90

-4711.82 663.64

-117.16 3291.32

-622.31

-338.63 5.0 46306.70

-12448.80 2292.51

-113.20 3504.56

-662.41

-73.12 6.0 57461.80

-20693.50 4405.17

-121.14 3633.52

-614.82 1.66 7.0 66450.10

-28314.10 6635.00

-129.61 3706.00

-510.84

-113.74 8.0 73652.70

-34919.90 8759.36

-136.91 3752.43

-391.36

-311.56 9.0 79378.80

-40316.60 10606.30

-141.55 3784.66

-280.29

-485.97 10.0 84125.10

-44860.80 12239.70

-143.00 3777.62

-152.58

-635.70 11.0 88066.60

-48540.60 13594.30

-142.74 3758.54

-33.78

-726.86 12.0 91416.80

-51619.90 14789.00

-141.31 3742.31 64.80

-833.14 13.0 94657.90

-54579.30 15916.70

-137.14 3652.04 215.05

-967.41 14.0 97332.40

-56854.80 16823.50

-133.83 3610.21 315.79

-959.48 15.0 99866.10

-58816.70 17560.80

-128.68 3529.41 430.14

-991.32 16.0 102093.00

-60412.40 18171.30

-124.64 3469.67 535.07

-1078.73 17.0 104419.00

-62150.90 18846.80

-118.62 3363.97 674.13

-1092.27 18.0 106439.00

-63357.20 19259.50

-114.31 3300.43 769.38

-1137.26 19.0 108613.00

-64655.80 19660.70

-107.71 3182.61 904.63

-1084.05 20.0 110475.00

-65506.20 19883.50

-103.32 3125.81 988.08

-1062.86 22.0 114223.00

-66854.40 19969.00

-91.34 2899.19 1260.81

-1076.58 24.0 117822.00

-67556.70 19641.80

-79.56 2684.32 1499.23

-1011.23 26.0 121396.00

-67752.70 18783.80

-68.61 2465.91 1753.65

-940.82 28.0 125040.00

-67445.30 17353.90

-55.51 2184.99 2059.27

-883.36 30.0 128075.00

-65562.60 14994.70

-45.58 2003.10 2244.12

-819.25 35.0 136419.00

-58633.40 6027.48

-15.81 1354.94 2757.84

-687.83 40.0 144776.00

-48670.50

-4898.54 5.02 1019.97 2652.57

-507.64

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-55 Table 2.4-3 (Page 2 of 8)

PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 14x14B A

B C

D E

F G

2.0 7962.04 1332.84

-83.96

-165.28 1836.65

-176.15

-859.65 2.25 10055.50 1296.32

-100.51

-156.80 2012.11

-217.67

-907.11 2.5 12332.50 1153.20

-110.56

-149.42 2185.46

-264.52

-845.06 2.75 15072.80 715.71

-82.42

-140.68 2336.22

-310.64

-833.26 3.0 18034.30 64.77

-24.88

-130.87 2450.80

-348.00

-857.34 4.0 30007.50

-4046.37 538.96

-110.22 2792.92

-469.98

-371.81 5.0 41033.00

-9824.17 1644.13

-108.10 2979.87

-509.22 122.91 6.0 50398.10

-16082.00 3115.79

-113.75 3084.72

-485.25 117.44 7.0 57782.60

-21657.00 4602.39

-121.19 3161.16

-433.49

-112.57 8.0 63670.20

-26431.00 6006.16

-127.70 3227.81

-382.20

-74.84 9.0 68390.50

-30359.70 7246.09

-131.82 3277.23

-336.08

-200.60 10.0 72284.50

-33630.50 8335.68

-132.71 3293.15

-279.98

-291.73 11.0 75584.30

-36387.10 9298.07

-132.38 3295.07

-227.50

-340.65 12.0 78425.20

-38681.30 10125.90

-130.36 3283.13

-176.12

-462.22 13.0 80928.60

-40624.70 10848.10

-127.28 3259.89

-127.73

-563.09 14.0 83136.90

-42279.70 11500.20

-124.50 3249.69

-97.40

-565.79 15.0 85398.00

-44023.70 12192.30

-119.64 3186.24

-30.11

-665.54 16.0 87257.50

-45137.70 12617.40

-113.94 3127.01 22.40

-678.95 17.0 89196.20

-46520.30 13209.90

-110.27 3091.45 63.17

-713.69 18.0 90991.80

-47570.50 13623.80

-104.55 3008.16 136.69

-772.63 19.0 92591.90

-48339.00 13957.70

-99.63 2967.34 161.34

-697.42 20.0 94285.30

-49165.00 14265.20

-93.25 2875.59 235.94

-721.92 22.0 97593.80

-50692.00 14904.40

-82.77 2745.24 324.79

-695.61 24.0 100677.00

-51565.30 15201.30

-71.53 2596.73 409.91

-701.93 26.0 103715.00

-52185.40 15380.80

-60.88 2445.30 499.31

-581.96 28.0 106669.00

-52197.30 15136.20

-49.42 2276.34 582.57

-547.22 30.0 109832.00

-52431.30 15114.20

-38.14 2103.73 641.34

-544.99 35.0 116933.00

-49435.10 12742.20

-10.82 1691.80 667.30

-388.35 40.0 123932.00

-43775.70 9268.80 15.25 1356.03 327.73

-339.10

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-56 Table 2.4-3 (Page 3 of 8)

PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 14x14C A

B C

D E

F G

2.0 7910.49 1566.52

-112.06

-173.92 1975.67

-202.57

-1582.61 2.25 10090.40 1516.08

-132.53

-164.22 2144.71

-245.91

-1586.24 2.5 12672.30 1230.85

-127.98

-154.40 2293.68

-288.88

-1526.05 2.75 15404.70 785.48

-103.88

-146.02 2435.58

-333.58

-1526.92 3.0 18263.20 174.52

-57.73

-138.13 2539.97

-369.83

-1372.54 4.0 30052.40

-3931.93 484.14

-116.91 2815.30

-467.36

-710.84 5.0 40995.00

-9796.91 1583.72

-113.09 2900.21

-451.56

-204.87 6.0 49804.50

-15620.10 2905.31

-119.64 2970.21

-399.85

-228.44 7.0 56671.50

-20724.30 4228.04

-129.87 3058.54

-347.83

-244.26 8.0 62114.70

-24957.40 5410.68

-135.49 3080.42

-267.82

-216.83 9.0 66532.70

-28492.00 6458.64

-138.92 3102.21

-196.64

-343.21 10.0 70257.00

-31538.30 7424.54

-139.96 3109.64

-131.37

-466.58 11.0 73240.40

-33856.10 8182.60

-139.49 3113.36

-77.52

-528.62 12.0 75830.10

-35829.20 8857.54

-137.30 3097.43

-23.81

-597.83 13.0 78304.00

-37697.30 9499.38

-132.64 3034.49 60.52

-690.28 14.0 80401.00

-39162.40 10022.20

-129.04 3004.11 112.39

-819.41 15.0 82413.50

-40565.20 10547.80

-125.00 2972.01 159.60

-815.35 16.0 84138.60

-41575.10 10920.50

-121.03 2935.91 206.01

-844.59 17.0 85994.20

-42654.40 11295.20

-113.82 2848.12 279.72

-924.47 18.0 87721.10

-43657.50 11664.00

-108.56 2775.07 353.35

-960.97 19.0 89122.20

-44109.80 11806.40

-103.94 2740.54 384.66

-864.21 20.0 90678.60

-44723.70 11996.00

-97.44 2648.86 459.77

-907.84 22.0 93894.70

-46071.00 12444.30

-85.57 2487.47 593.03

-912.09 24.0 96742.60

-46597.20 12482.60

-75.19 2358.14 688.79

-833.76 26.0 99697.50

-47055.90 12472.30

-63.23 2185.39 810.10

-803.84 28.0 102343.00

-46639.70 11970.90

-52.13 2038.03 893.63

-704.66 30.0 105173.00

-46148.00 11326.10

-41.21 1856.73 1002.71

-620.51 35.0 111963.00

-42828.60 8640.91

-13.96 1473.64 1063.44

-455.86 40.0 118574.00

-36526.50 4330.66 12.00 1111.29 892.32

-351.40

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-57 Table 2.4-3 (Page 4 of 8)

PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 15x15A/B/C A

B C

D E

F G

2.0 6771.99 897.63

-45.95

-155.96 1478.91

-112.57

-571.21 2.25 8543.84 862.70

-53.16

-148.35 1638.47

-142.90

-603.00 2.5 10454.10 757.88

-56.51

-143.91 1802.08

-178.39

-613.38 2.75 12589.40 536.75

-50.58

-136.31 1939.28

-212.48

-598.75 3.0 15043.50 106.18

-18.51

-127.37 2049.65

-242.76

-584.58 4.0 25256.40

-2809.40 320.40

-108.47 2382.23

-339.78

-246.30 5.0 34995.70

-7157.77 1037.70

-104.27 2547.85

-373.57 64.26 6.0 43079.90

-11755.40 1968.81

-110.42 2669.55

-367.08 207.73 7.0 49495.50

-15880.10 2915.99

-117.70 2745.06

-335.00 79.17 8.0 54674.20

-19541.50 3863.26

-124.97 2823.26

-307.52

-139.52 9.0 58746.90

-22465.30 4666.71

-128.88 2870.36

-274.05

-284.74 10.0 62159.00

-24900.00 5358.04

-129.81 2882.28

-231.65

-307.41 11.0 64980.00

-26916.40 5974.92

-128.99 2890.02

-197.70

-320.91 12.0 67449.80

-28657.30 6533.20

-126.96 2889.14

-168.72

-358.64 13.0 69587.80

-30096.10 7005.49

-125.03 2881.70

-138.49

-417.57 14.0 71617.00

-31412.90 7443.05

-120.37 2839.04

-95.47

-497.72 15.0 73320.90

-32442.90 7811.27

-117.59 2836.73

-78.55

-582.44 16.0 75078.70

-33504.10 8184.69

-111.70 2773.08

-28.70

-569.58 17.0 76605.90

-34256.30 8446.38

-106.43 2722.31 10.58

-648.37 18.0 78201.90

-35135.30 8779.71

-102.00 2687.99 34.04

-637.10 19.0 79683.00

-35825.50 9024.65

-96.68 2626.60 78.21

-644.17 20.0 81040.00

-36264.40 9175.96

-90.42 2571.71 105.53

-621.79 22.0 83842.80

-37347.80 9582.93

-79.77 2452.81 179.87

-678.83 24.0 86457.20

-37934.30 9779.99

-69.09 2348.63 223.29

-555.43 26.0 89143.70

-38488.40 9965.70

-58.22 2222.80 276.21

-541.65 28.0 91552.10

-38289.80 9775.89

-47.03 2083.59 328.54

-483.47 30.0 93976.80

-37775.30 9380.97

-35.17 1933.91 367.06

-412.13 35.0 99743.70

-35109.80 7937.17

-10.10 1701.23 242.55

-292.95 40.0 105747.00

-30710.40 5734.70 16.14 1409.70

-19.63

-330.25

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-58 Table 2.4-3 (Page 5 of 8)

PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 15x15D/E/F/H/I A

B C

D E

F G

2.0 6290.79 883.39

-49.29

-150.42 1348.67

-93.23

-194.84 2.25 7850.16 906.09

-62.37

-145.85 1507.07

-121.33

-234.20 2.5 9917.64 729.63

-57.61

-138.51 1649.34

-150.19

-389.61 2.75 12039.70 498.88

-50.28

-132.19 1776.46

-179.02

-384.86 3.0 14308.20 140.88

-27.37

-126.11 1896.47

-208.80

-424.35 4.0 24246.40

-2585.64 274.38

-105.96 2197.31

-292.15

-98.88 5.0 33660.00

-6672.88 931.23

-104.57 2380.99

-330.06 323.27 6.0 41534.90

-11039.20 1790.84

-111.20 2485.37

-318.04 436.06 7.0 47737.40

-14940.00 2668.46

-119.75 2572.84

-293.94 394.87 8.0 52510.40

-18097.60 3446.19

-126.75 2647.38

-274.16 310.51 9.0 56484.50

-20845.30 4162.00

-129.08 2662.71

-225.75 158.84 10.0 59692.00

-23093.90 4799.05

-130.53 2692.07

-199.57 18.86 11.0 62307.70

-24865.90 5320.34

-130.34 2710.88

-176.52

-96.66 12.0 64497.20

-26247.00 5725.38

-127.89 2691.98

-137.42

-152.99 13.0 66473.70

-27479.90 6111.71

-124.64 2678.39

-110.34

-220.62 14.0 68322.50

-28605.10 6471.87

-120.12 2648.26

-78.83

-317.16 15.0 69880.10

-29416.90 6732.96

-115.83 2620.06

-52.26

-351.02 16.0 71504.30

-30337.40 7046.36

-110.89 2583.27

-22.60

-386.91 17.0 72938.30

-31008.00 7269.02

-105.81 2541.55 5.22

-421.21 18.0 74306.50

-31601.90 7471.26

-100.67 2498.95 31.67

-421.69 19.0 75649.10

-32149.50 7661.36

-95.47 2449.77 61.38

-439.23 20.0 76868.40

-32525.30 7793.09

-90.99 2421.09 73.14

-450.75 22.0 79592.40

-33604.00 8197.86

-78.90 2293.07 142.14

-486.11 24.0 81996.10

-34015.70 8295.91

-67.98 2173.93 196.55

-435.49 26.0 84232.50

-34067.60 8271.85

-57.61 2083.11 215.81

-374.64 28.0 86620.60

-34049.50 8171.94

-45.82 1954.61 249.73

-400.41 30.0 88983.60

-33826.80 8026.95

-34.27 1835.41 255.33

-353.18 35.0 94579.10

-31817.80 7120.43

-8.81 1596.94 131.34

-263.56 40.0 100058.00

-27653.80 5318.64 17.12 1355.45

-187.62

-273.88

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-59 Table 2.4-3 (Page 6 of 8)

PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 16X16A A

B C

D E

F G

2.0 7213.94 1062.48

-60.18

-163.16 1632.73

-137.39

-660.90 2.25 9068.86 1052.65

-73.90

-157.12 1812.61

-174.53

-682.57 2.5 11282.40 881.74

-74.10

-149.28 1970.43

-212.23

-710.99 2.75 13602.30 625.18

-68.06

-143.44 2124.68

-253.65

-734.52 3.0 16226.30 143.97

-32.51

-136.73 2255.52

-291.73

-699.79 4.0 27528.60

-3346.42 393.54

-115.66 2587.71

-397.43

-273.55 5.0 38357.70

-8605.59 1312.06

-110.58 2719.25

-409.35 60.77 6.0 47353.00

-14184.20 2511.45

-117.96 2810.98

-373.58 26.38 7.0 54492.70

-19227.40 3751.22

-126.74 2889.14

-321.58

-84.61 8.0 60159.30

-23487.00 4884.62

-133.44 2918.29

-242.53

-126.66 9.0 64663.30

-26994.20 5900.01

-137.02 2946.64

-181.25

-285.69 10.0 68346.00

-29851.40 6755.60

-138.49 2958.18

-120.30

-384.11 11.0 71361.10

-32184.10 7502.54

-138.40 2964.72

-68.91

-497.04 12.0 74014.20

-34136.30 8127.59

-135.73 2938.32

-7.78

-627.98 13.0 76326.40

-35820.10 8697.58

-132.72 2908.57 49.64

-715.32 14.0 78450.30

-37288.70 9197.21

-128.85 2871.70 104.32

-771.96 15.0 80439.10

-38636.00 9667.15

-124.14 2815.86 168.64

-851.14 16.0 82142.00

-39610.20 10013.20

-120.20 2790.66 203.72

-859.48 17.0 83886.70

-40590.10 10336.30

-114.04 2714.78 270.50

-870.62 18.0 85580.90

-41545.60 10677.80

-108.53 2648.66 332.69

-921.15 19.0 87028.10

-42030.60 10787.80

-102.57 2576.39 390.15

-880.17 20.0 88490.60

-42584.60 10956.70

-97.67 2529.96 430.91

-912.08 22.0 91586.50

-43770.60 11272.60

-85.21 2343.82 579.90

-878.01 24.0 94293.80

-44158.40 11248.70

-74.44 2224.40 656.22

-824.58 26.0 97086.50

-44420.30 11078.90

-62.82 2045.62 784.53

-737.98 28.0 99965.10

-44515.00 10777.60

-51.29 1871.32 897.77

-719.30 30.0 102352.00

-43418.60 9831.79

-40.46 1725.50 957.49

-626.62 35.0 109039.00

-40353.50 7075.81

-12.07 1286.03 1106.60

-531.72 40.0 115345.00

-34020.20 2448.15 13.49 928.92 963.44

-395.64

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-60 Table 2.4-3 (Page 7 of 8)

PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 17x17A/16x16B/C A

B C

D E

F G

2.0 7482.84 749.18

-32.06

-153.69 1490.54

-111.64

-301.94 2.25 9138.06 783.14

-45.73

-148.43 1678.27

-147.42

-271.38 2.5 11115.90 682.88

-49.46

-143.38 1855.10

-184.65

-248.90 2.75 13492.40 392.81

-34.32

-137.63 2018.42

-224.60

-364.95 3.0 15985.10 3.54

-9.05

-128.84 2149.50

-260.42

-263.00 4.0 27326.30

-3316.13 388.73

-110.89 2545.62

-376.10

-60.44 5.0 38630.20

-8729.17 1335.65

-109.86 2754.84

-407.49 244.70 6.0 48364.20

-14788.30 2652.90

-117.55 2878.88

-375.72 252.15 7.0 56144.10

-20415.70 4068.96

-128.12 2970.68

-312.43

-145.42 8.0 62319.20

-25122.10 5332.37

-133.94 2986.20

-212.65

-192.32 9.0 67097.40

-28916.30 6441.26

-139.07 3028.70

-142.12

-304.90 10.0 71141.80

-32210.80 7461.17

-140.60 3037.68

-63.75

-484.40 11.0 74293.50

-34623.40 8214.63

-140.16 3026.35 11.71

-567.89 12.0 77101.60

-36783.10 8922.19

-138.37 3008.48 83.17

-677.97 13.0 79705.10

-38760.90 9576.13

-134.21 2949.33 173.71

-820.83 14.0 81840.20

-40208.40 10063.30

-130.61 2915.99 236.79

-867.80 15.0 83845.30

-41560.10 10535.80

-126.12 2867.51 306.60

-940.08 16.0 85751.10

-42671.70 10876.60

-120.77 2799.15 386.28

-990.12 17.0 87613.20

-43744.30 11214.60

-114.75 2722.88 466.15

-1028.96 18.0 89198.60

-44487.50 11451.40

-110.00 2673.61 522.32

-974.28 19.0 90843.80

-45204.50 11637.70

-103.89 2591.93 602.99

-1048.14 20.0 92361.20

-45701.20 11710.50

-98.45 2507.40 689.65

-1034.50 22.0 95455.20

-46715.70 11886.10

-86.86 2353.10 835.28

-1006.44 24.0 98319.40

-46988.20 11622.80

-74.63 2169.86 995.06

-941.81 26.0 101240.00

-47039.80 11136.00

-62.32 1971.79 1168.97

-907.73 28.0 103863.00

-46243.10 10186.30

-51.51 1822.28 1270.39

-758.20 30.0 106638.00

-45299.90 9011.04

-39.38 1598.42 1447.93

-698.69 35.0 113059.00

-40056.10 4113.55

-12.17 1169.02 1660.44

-557.52 40.0 119131.00

-30799.70

-3521.78 14.35 791.94 1564.09

-401.82

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-61 Table 2.4-3 (Page 8 of 8)

PWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 17x17B/C A

B C

D E

F G

2.0 6766.33 744.89

-33.96

-154.11 1387.05

-99.30

-455.94 2.25 8406.78 735.84

-42.13

-148.76 1546.40

-127.76

-412.22 2.5 10326.00 618.40

-42.67

-140.84 1696.17

-158.83

-428.21 2.75 12425.70 400.95

-35.11

-134.79 1833.92

-190.65

-448.69 3.0 14787.40 16.36

-8.09

-128.41 1953.16

-221.24

-426.08 4.0 25076.00

-2855.35 319.19

-107.73 2268.19

-307.82

-118.54 5.0 34842.80

-7144.52 1015.11

-107.42 2457.65

-342.14 294.08 6.0 43259.40

-11920.40 1970.81

-113.08 2547.52

-316.78 82.08 7.0 49884.40

-16230.60 2962.56

-122.92 2650.94

-291.11 127.95 8.0 55105.20

-19804.80 3845.74

-128.64 2682.52

-232.47

-61.87 9.0 59268.90

-22820.00 4674.45

-133.56 2742.72

-203.91

-265.03 10.0 62653.20

-25227.80 5347.65

-134.19 2744.28

-150.34

-229.28 11.0 65528.50

-27328.80 5990.85

-134.07 2759.67

-117.12

-349.73 12.0 67925.00

-28930.10 6470.25

-131.66 2738.04

-69.75

-467.93 13.0 70014.00

-30295.30 6903.21

-128.41 2714.49

-27.74

-580.42 14.0 71939.40

-31542.90 7318.09

-124.70 2688.09 8.93

-630.83 15.0 73678.50

-32578.30 7669.57

-120.41 2659.19 41.04

-637.54 16.0 75313.80

-33488.20 7973.96

-115.46 2610.74 86.53

-708.01 17.0 76870.20

-34276.40 8238.11

-110.15 2563.22 123.29

-739.52 18.0 78338.30

-34971.50 8477.60

-104.26 2505.00 166.49

-731.14 19.0 79849.90

-35703.80 8726.57

-99.14 2447.13 211.29

-756.38 20.0 81109.20

-36047.10 8827.48

-93.99 2404.21 235.46

-751.74 22.0 83793.40

-36898.90 9088.73

-82.74 2281.57 313.80

-704.73 24.0 86424.70

-37453.70 9205.18

-70.11 2134.35 393.96

-654.44 26.0 88971.30

-37671.00 9134.01

-58.64 1983.82 478.46

-659.93 28.0 91497.60

-37723.60 9032.79

-47.61 1861.20 520.75

-564.47 30.0 93706.20

-36961.70 8512.11

-37.17 1743.83 543.52

-523.93 35.0 99798.50

-34670.70 6911.55

-9.53 1376.43 593.61

-406.67 40.0 105384.00

-29185.20 3708.34 16.92 1086.25 354.06

-343.59

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-62 Table 2.4-4 (Page 1 of 10)

BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 7x7B & 10x10F A

B C

D E

F G

2.0 15761.10 10171.40

-1983.74

-180.41 4533.44

-1035.69

-1020.71 2.25 20683.90 10100.50

-2362.96

-171.37 4924.21

-1259.16

-1149.28 2.5 25710.50 9847.51

-2788.08

-162.18 5329.88

-1548.05

-1048.31 2.75 31858.60 7767.18

-2661.83

-154.93 5675.76

-1804.31

-992.87 3.0 38703.40 4333.22

-2101.88

-144.94 5898.42

-1990.59

-1030.87 4.0 65948.40

-16991.70 3924.57

-118.43 6390.16

-2406.62

-614.30 5.0 90881.20

-47264.90 16771.40

-112.75 6498.93

-2241.12

-192.49 6.0 111776.00

-79261.50 33399.20

-115.32 6416.04

-1620.07

-84.57 7.0 127348.00

-107023.00 50534.70

-139.25 6848.43

-1458.29

-14.89 8.0 140072.00

-130028.00 65223.10

-144.93 6836.24

-857.79

-99.75 9.0 150749.00

-150213.00 79005.50

-147.77 6773.51

-231.87

-331.15 10.0 158943.00

-167178.00 92612.70

-164.66 7287.36

-461.83

-382.12 11.0 165714.00

-179168.00 101557.00

-164.07 7241.92

-45.10

-521.50 12.0 171975.00

-190727.00 110548.00

-161.09 7166.19 380.43

-589.16 13.0 177624.00

-200947.00 118921.00

-158.82 7131.17 664.17

-667.75 14.0 182802.00

-210117.00 126526.00

-154.60 7016.50 1083.45

-747.88 15.0 186884.00

-214518.00 128584.00

-147.82 6809.36 1591.41

-783.35 16.0 191316.00

-221293.00 134071.00

-142.04 6646.92 2019.29

-841.16 17.0 195369.00

-231600.00 147624.00

-158.43 7404.40 946.55

-820.02 18.0 199404.00

-236224.00 150408.00

-148.69 7053.70 1655.35

-883.27 19.0 203726.00

-243272.00 157476.00

-143.31 6936.71 1903.09

-895.71 20.0 206861.00

-245479.00 159023.00

-137.13 6829.41 2091.47

-903.40 22.0 213325.00

-250875.00 163825.00

-127.55 6623.17 2500.20

-800.98 24.0 220063.00

-255065.00 166460.00

-114.40 6330.37 2896.83

-803.85 26.0 226903.00

-262541.00 177379.00

-115.77 6627.51 2189.72

-651.65 28.0 234964.00

-270961.00 187677.00

-102.37 6255.46 2595.08

-735.34 30.0 241796.00

-272482.00 188002.00

-88.80 5779.54 3315.93

-731.24 35.0 257457.00

-265751.00 183333.00

-71.68 5676.93 1648.24

-511.23 40.0 282525.00

-292276.00 240288.00

-43.47 4948.25 152.96

-833.96

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-63 Table 2.4-4 (Page 2 of 10)

BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 8x8B A

B C

D E

F G

2.0 15913.80 11664.70

-2480.99

-179.56 4694.73

-1100.00

-1003.87 2.25 20652.00 12023.80

-3025.66

-174.12 5204.92

-1412.29

-979.17 2.5 26986.10 10399.30

-3032.60

-163.94 5594.88

-1694.85

-1213.71 2.75 33074.30 8670.65

-3129.69

-156.84 5959.94

-1975.74

-1054.90 3.0 39987.50 5388.94

-2722.03

-146.15 6189.85

-2184.18

-1039.58 4.0 68821.60

-18071.10 4016.97

-119.21 6655.64

-2578.72

-677.77 5.0 95032.70

-50959.00 18228.50

-113.67 6737.08

-2341.46

-253.74 6.0 117864.00

-88879.60 39468.80

-128.75 6937.68

-1918.61

-203.01 7.0 133919.00

-117151.00 56431.30

-139.69 6960.80

-1212.83

-123.38 8.0 147621.00

-142952.00 73246.80

-143.67 6879.18

-441.73

-342.11 9.0 158036.00

-165478.00 90946.70

-167.32 7480.35

-551.45

-378.22 10.0 166796.00

-181378.00 101771.00

-165.98 7346.03 114.50

-504.04 11.0 174312.00

-195869.00 112810.00

-165.26 7291.07 642.48

-648.03 12.0 180736.00

-207916.00 122412.00

-163.34 7243.01 1055.04

-742.81 13.0 187002.00

-219945.00 132127.00

-159.70 7084.08 1641.84

-903.88 14.0 192382.00

-229413.00 139613.00

-156.32 7001.62 2085.84

-972.60 15.0 196087.00

-233618.00 142299.00

-151.48 6860.06 2570.55

-883.73 16.0 202268.00

-249608.00 159974.00

-162.80 7359.57 1999.93

-1048.13 17.0 206376.00

-256109.00 166401.00

-159.20 7309.03 2257.68

-1062.93 18.0 209117.00

-255071.00 162389.00

-151.82 7125.28 2596.49

-891.61 19.0 213124.00

-261295.00 168674.00

-146.82 7004.96 2966.11

-951.40 20.0 217047.00

-267281.00 175609.00

-141.96 6943.62 3118.99

-1012.59 22.0 223569.00

-268761.00 171389.00

-127.42 6436.52 4175.11

-877.23 24.0 233533.00

-291046.00 200512.00

-131.73 6830.33 3613.57

-988.74 26.0 238557.00

-284966.00 188216.00

-118.63 6424.02 4316.86

-862.50 28.0 245385.00

-285588.00 185055.00

-105.51 6116.61 4651.69

-844.39 30.0 254559.00

-295608.00 196106.00

-100.36 6027.39 4465.31

-886.90 35.0 272231.00

-295589.00 203313.00

-71.05 5259.94 4464.18

-744.47 40.0 290782.00

-286198.00 204311.00

-50.38 4868.38 2364.75

-614.59

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-64 Table 2.4-4 (Page 3 of 10)

BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 8x8C/D/E A

B C

D E

F G

2.0 16663.00 10889.80

-2211.52

-182.17 4831.25

-1175.27

-1260.49 2.25 21598.90 10980.20

-2691.18

-176.65 5300.72

-1453.46

-1219.04 2.5 27348.40 10071.30

-2967.33

-165.41 5680.31

-1735.86

-1252.79 2.75 33467.10 8232.39

-2999.52

-158.56 6061.56

-2033.93

-1086.98 3.0 40382.30 4849.42

-2525.53

-148.53 6314.10

-2257.89

-1075.95 4.0 68954.10

-18263.30 4048.93

-123.13 6850.62

-2734.70

-652.59 5.0 96324.30

-53730.10 19778.60

-114.90 6841.59

-2381.30

-353.71 6.0 118229.00

-89906.60 39997.30

-134.45 7190.60

-2120.86

-143.41 7.0 134948.00

-119919.00 58227.10

-143.18 7200.03

-1397.69

-170.37 8.0 149092.00

-147517.00 76590.50

-149.16 7110.00

-528.97

-313.19 9.0 159771.00

-170139.00 93968.00

-170.19 7649.69

-595.38

-403.04 10.0 168715.00

-187828.00 107088.00

-172.19 7651.82

-46.57

-555.81 11.0 176169.00

-201821.00 117349.00

-170.83 7550.84 552.84

-651.76 12.0 182662.00

-214445.00 127628.00

-169.36 7519.56 997.32

-756.73 13.0 189114.00

-227085.00 137699.00

-166.11 7388.07 1583.27

-844.97 14.0 195273.00

-239345.00 148361.00

-160.79 7228.22 2124.28

-1017.11 15.0 199939.00

-249862.00 159949.00

-174.10 7782.47 1566.35

-1026.32 16.0 204899.00

-258274.00 166856.00

-167.77 7534.06 2227.05

-1070.51 17.0 209356.00

-265290.00 173458.00

-161.96 7463.49 2386.89

-1040.14 18.0 213546.00

-272476.00 180667.00

-158.41 7387.49 2763.66

-1098.37 19.0 217506.00

-277100.00 183949.00

-150.21 7155.18 3240.82

-1107.07 20.0 219837.00

-275266.00 179705.00

-145.05 7009.96 3638.55

-1007.16 22.0 228092.00

-285272.00 186688.00

-133.55 6672.08 4473.64

-1122.87 24.0 237213.00

-304032.00 211958.00

-136.95 7000.92 4086.48

-1049.61 26.0 242060.00

-297359.00 199620.00

-125.83 6734.22 4465.79

-972.10 28.0 249432.00

-299622.00 196900.00

-111.26 6222.03 5440.43

-914.71 30.0 263307.00

-334844.00 247655.00

-111.83 6452.32 4775.31

-1191.53 35.0 273393.00

-291765.00 178985.00

-83.84 5736.80 4650.87

-621.35 40.0 293153.00

-283353.00 175255.00

-57.06 4937.79 3684.27

-559.25

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-65 Table 2.4-4 (Page 4 of 10)

BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 9x9A A

B C

D E

F G

2.0 16564.30 12063.20

-2586.67

-184.87 4976.49

-1228.06

-894.91 2.25 22071.80 11834.70

-3015.91

-174.88 5443.22

-1518.94

-1014.33 2.5 27866.60 10993.50

-3286.54

-168.71 5965.88

-1909.06

-1027.88 2.75 34375.10 9004.62

-3367.62

-158.97 6305.05

-2182.06

-933.24 3.0 41566.50 5392.11

-2800.23

-149.79 6613.45

-2462.36

-904.38 4.0 72006.50

-20264.40 4921.01

-123.85 7211.86

-3004.62

-603.22 5.0 100197.00

-57315.80 21669.60

-118.72 7356.33

-2796.24

-243.52 6.0 124367.00

-99348.10 46264.80

-136.71 7648.05

-2394.38

-67.58 7.0 143009.00

-134740.00 68824.10

-143.35 7544.90

-1403.30

-173.80 8.0 157479.00

-165996.00 92255.30

-168.05 8114.30

-1315.88

-266.71 9.0 169636.00

-191379.00 110928.00

-172.50 8069.55

-500.37

-450.57 10.0 179282.00

-211202.00 125969.00

-172.12 7976.57 283.36

-617.13 11.0 187512.00

-228637.00 140325.00

-172.16 7928.03 894.69

-760.39 12.0 195321.00

-245580.00 154682.00

-170.38 7824.20 1596.02

-863.97 13.0 202110.00

-263050.00 173293.00

-187.18 8470.09 1003.55

-953.17 14.0 208171.00

-274758.00 183332.00

-179.75 8249.83 1717.21

-1103.07 15.0 213590.00

-284590.00 191650.00

-175.64 8098.33 2289.04

-1165.13 16.0 218091.00

-292503.00 199557.00

-171.84 8035.82 2659.38

-1119.03 17.0 223491.00

-302449.00 208733.00

-164.92 7833.36 3192.21

-1255.80 18.0 226523.00

-304524.00 209895.00

-162.71 7829.04 3410.57

-1091.33 19.0 231702.00

-312496.00 215730.00

-153.73 7552.13 4052.91

-1189.12 20.0 236531.00

-324776.00 232293.00

-164.72 8073.05 3368.73

-1233.57 22.0 244888.00

-335452.00 241932.00

-150.44 7566.26 4642.58

-1160.69 24.0 252171.00

-340795.00 244542.00

-141.18 7321.23 5355.16

-1142.40 26.0 259438.00

-343494.00 244340.00

-129.66 7094.56 5645.82

-1119.92 28.0 268823.00

-359239.00 266068.00

-130.16 7204.93 5605.85

-1064.30 30.0 277221.00

-363922.00 268930.00

-116.96 6799.84 6219.78

-1037.79 35.0 294285.00

-351643.00 245914.00

-99.35 6404.25 5923.44

-713.23 40.0 324174.00

-389397.00 319233.00

-77.68 5933.52 3992.56

-1188.62

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-66 Table 2.4-4 (Page 5 of 10)

BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 9x9B A

B C

D E

F G

2.0 17186.80 11657.20

-2441.58

-183.45 5049.98

-1246.51

-1156.40 2.25 21800.20 12295.50

-3074.77

-180.94 5660.86

-1631.58

-1064.82 2.5 28010.00 11198.70

-3349.88

-169.84 6074.18

-1943.73

-1220.46 2.75 34607.80 9092.75

-3327.98

-161.55 6476.70

-2279.47

-1090.70 3.0 41425.40 6300.12

-3202.59

-151.95 6782.84

-2566.85

-1000.46 4.0 71942.80

-18734.90 3920.65

-125.38 7367.52

-3119.27

-631.75 5.0 101151.00

-57291.00 21182.10

-118.05 7377.24

-2721.50

-361.88 6.0 125823.00

-99944.80 45636.60

-136.47 7588.00

-2124.69

-262.67 7.0 144638.00

-135378.00 67687.60

-143.88 7447.72

-995.76

-340.94 8.0 159872.00

-168383.00 91921.20

-168.66 7933.70

-673.04

-395.74 9.0 172305.00

-194121.00 110332.00

-172.16 7831.09 301.31

-634.37 10.0 181683.00

-213140.00 124418.00

-173.36 7740.03 1165.16

-753.12 11.0 190922.00

-232977.00 140095.00

-171.28 7581.53 2053.29

-1027.00 12.0 198213.00

-248066.00 152236.00

-170.70 7492.96 2781.03

-1087.99 13.0 205947.00

-268590.00 173240.00

-187.42 8096.44 2390.78

-1199.48 14.0 211867.00

-280583.00 184192.00

-183.14 8023.23 2903.27

-1325.04 15.0 217071.00

-289407.00 190649.00

-177.77 7760.30 3819.17

-1355.68 16.0 221340.00

-294404.00 193178.00

-173.59 7653.54 4235.81

-1282.26 17.0 227205.00

-306489.00 204027.00

-164.96 7309.81 5290.73

-1440.44 18.0 231085.00

-310612.00 206608.00

-160.03 7176.88 5715.32

-1383.11 19.0 236345.00

-320398.00 215697.00

-153.84 7020.00 6284.82

-1522.44 20.0 240125.00

-328538.00 227545.00

-170.25 7836.24 5008.11

-1382.77 22.0 245672.00

-325279.00 216287.00

-158.18 7517.98 5919.63

-1187.15 24.0 256479.00

-345503.00 236771.00

-144.07 6970.57 7508.12

-1317.75 26.0 260950.00

-331434.00 205388.00

-130.57 6497.58 8638.70

-1076.78 28.0 269984.00

-343628.00 218366.00

-134.58 6861.68 8165.52

-1062.58 30.0 278259.00

-348285.00 221391.00

-123.31 6538.19 8720.28

-1076.88 35.0 297697.00

-344053.00 202586.00

-105.06 6094.38 9194.58

-852.15 40.0 331243.00

-401432.00 313358.00

-81.82 5561.33 7636.50

-1470.42

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-67 Table 2.4-4 (Page 6 of 10)

BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 9x9C/D A

B C

D E

F G

2.0 16691.80 11823.60

-2447.14

-185.99 5008.36

-1243.90

-1059.30 2.25 21740.60 12301.10

-3136.66

-173.22 5422.51

-1511.79

-1061.56 2.5 27709.70 11300.00

-3398.46

-167.10 5898.90

-1850.17

-1171.40 2.75 33988.10 9774.59

-3696.16

-158.15 6268.38

-2155.04

-974.14 3.0 41117.20 6515.41

-3381.03

-148.32 6548.78

-2413.74

-948.98 4.0 71428.60

-18297.80 3576.44

-123.51 7125.21

-2923.50

-632.21 5.0 100397.00

-56458.80 20611.70

-115.75 7125.58

-2528.06

-313.97 6.0 124283.00

-97234.10 43750.10

-135.36 7393.89

-2038.45

-178.07 7.0 142677.00

-131502.00 64937.90

-142.42 7276.64

-994.67

-255.89 8.0 158111.00

-164750.00 89150.00

-165.13 7682.79

-614.18

-382.56 9.0 169539.00

-187815.00 105688.00

-170.16 7701.54 95.21

-536.66 10.0 179168.00

-207560.00 120407.00

-172.05 7615.14 907.40

-757.15 11.0 187428.00

-224318.00 133228.00

-170.11 7472.64 1710.47

-885.30 12.0 195546.00

-241540.00 147050.00

-166.19 7281.30 2560.85

-1135.94 13.0 202256.00

-258699.00 164971.00

-182.40 7906.42 2044.37

-1182.19 14.0 207838.00

-268927.00 173192.00

-178.93 7770.91 2703.98

-1224.09 15.0 213979.00

-281611.00 184781.00

-172.75 7552.21 3409.13

-1276.86 16.0 217809.00

-285839.00 187221.00

-168.56 7458.11 3805.42

-1317.69 17.0 223749.00

-297214.00 196642.00

-160.86 7141.47 4676.19

-1362.21 18.0 226075.00

-295937.00 193130.00

-157.66 7127.19 4895.03

-1291.13 19.0 230997.00

-304670.00 201281.00

-150.53 6907.85 5558.32

-1353.07 20.0 238022.00

-324930.00 227066.00

-158.32 7284.25 5103.45

-1464.16 22.0 243676.00

-322706.00 217208.00

-147.77 6978.74 5979.30

-1239.05 24.0 251683.00

-332524.00 227486.00

-137.48 6744.91 6651.45

-1261.39 26.0 256408.00

-321812.00 204514.00

-125.79 6394.39 7373.18

-1135.32 28.0 264537.00

-330729.00 215269.00

-131.03 6864.20 6415.84

-1014.55 30.0 273958.00

-341208.00 225146.00

-115.29 6196.43 7947.39

-1073.39 35.0 292385.00

-333153.00 204415.00

-98.00 5956.86 7222.98

-860.79 40.0 329247.00

-419504.00 371883.00

-71.42 4943.73 7633.01

-1618.27

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-68 Table 2.4-4 (Page 7 of 10)

BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 9x9E/F A

B C

D E

F G

2.0 16854.60 11084.70

-2322.04

-181.73 4769.99

-1147.12

-810.29 2.25 21630.80 11546.20

-2940.96

-172.49 5228.13

-1436.00

-839.61 2.5 27849.90 10029.20

-2985.66

-164.15 5650.51

-1736.59

-1040.92 2.75 34540.60 7548.11

-2786.62

-154.38 5990.92

-2013.50

-935.15 3.0 41307.10 4337.80

-2362.16

-146.82 6295.85

-2275.82

-884.96 4.0 70768.40

-20480.20 5197.61

-121.39 6876.47

-2797.83

-537.40 5.0 98180.80

-56583.30 21720.10

-115.24 7004.63

-2612.66

-168.15 6.0 120573.00

-94683.40 43765.30

-134.45 7390.91

-2400.88 20.85 7.0 138493.00

-128353.00 65326.00

-141.23 7368.45

-1657.87 2.12 8.0 151304.00

-154813.00 84923.70

-165.48 7997.42

-1799.73

-3.75 9.0 162835.00

-178601.00 102770.00

-169.20 8012.87

-1222.27

-178.21 10.0 173089.00

-200396.00 119704.00

-169.43 7906.04

-489.94

-481.35 11.0 180227.00

-213998.00 130552.00

-169.48 7924.61

-143.28

-537.04 12.0 188058.00

-230819.00 144797.00

-165.45 7782.15 482.35

-705.69 13.0 193490.00

-240795.00 153382.00

-163.80 7756.04 834.76

-753.66 14.0 199338.00

-255751.00 170303.00

-178.59 8424.78 16.81

-795.55 15.0 204471.00

-264530.00 177215.00

-172.61 8186.47 708.91

-873.25 16.0 209807.00

-275635.00 189071.00

-167.97 8087.71 1042.99

-936.73 17.0 214452.00

-282609.00 194830.00

-159.86 7819.12 1616.41

-906.17 18.0 217197.00

-283928.00 195786.00

-157.56 7869.81 1568.69

-890.15 19.0 221266.00

-288837.00 199363.00

-149.64 7592.40 2213.50

-965.82 20.0 225737.00

-295774.00 205279.00

-143.23 7337.40 2875.11

-876.23 22.0 234598.00

-314227.00 231133.00

-148.51 7825.76 2021.35

-879.15 24.0 242046.00

-320606.00 235951.00

-134.75 7367.58 2926.98

-913.50 26.0 247960.00

-318479.00 229552.00

-123.51 7133.33 3171.11

-783.22 28.0 261521.00

-352854.00 278305.00

-120.41 7120.21 3024.72

-1121.44 30.0 264913.00

-340198.00 263913.00

-111.92 6968.28 2888.33

-788.23 35.0 288082.00

-360268.00 293412.00

-86.40 6220.44 2894.70

-961.02 40.0 298948.00

-303570.00 215523.00

-55.72 5417.82 785.23

-415.39

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-69 Table 2.4-4 (Page 8 of 10)

BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 9x9G A

B C

D E

F G

2.0 18157.70 12664.10

-2736.69

-182.35 5344.31

-1383.11

-916.79 2.25 23646.70 12752.10

-3248.16

-178.95 5971.94

-1793.73

-925.78 2.5 29660.10 12309.80

-3821.64

-169.21 6473.09

-2183.65

-879.92 2.75 36525.80 10358.80

-3962.11

-162.46 6968.29

-2613.38

-863.49 3.0 44006.40 7030.85

-3698.49

-153.38 7336.54

-2971.63

-809.92 4.0 77288.30

-21207.50 4543.15

-125.70 8058.78

-3705.78

-537.87 5.0 110686.00

-69960.20 29062.30

-130.54 8442.77

-3626.36

-336.85 6.0 137786.00

-118830.00 58088.00

-136.52 8339.36

-2532.48

-201.40 7.0 160795.00

-169293.00 94340.50

-161.16 8672.27

-1671.25

-379.07 8.0 177763.00

-207034.00 122389.00

-170.18 8619.96

-400.24

-562.99 9.0 193108.00

-243101.00 150849.00

-171.94 8368.05 1156.18

-881.11 10.0 205042.00

-275555.00 181997.00

-195.35 9071.69 1098.87

-1083.51 11.0 215280.00

-300568.00 204362.00

-194.55 8934.09 2200.13

-1266.10 12.0 223585.00

-319189.00 220301.00

-191.69 8775.21 3201.84

-1325.62 13.0 230947.00

-335777.00 234994.00

-189.96 8659.97 4110.52

-1472.39 14.0 239135.00

-355478.00 253619.00

-183.93 8406.36 5194.67

-1726.13 15.0 245572.00

-374776.00 278406.00

-203.34 9278.36 4194.86

-1666.34 16.0 251881.00

-387322.00 288544.00

-193.80 8836.24 5557.89

-1689.56 17.0 257861.00

-401610.00 304798.00

-189.68 8737.81 6220.47

-1840.71 18.0 262232.00

-408488.00 311370.00

-185.11 8602.16 6925.67

-1728.75 19.0 265329.00

-406025.00 301388.00

-178.52 8347.70 7730.36

-1689.95 20.0 271234.00

-419055.00 315509.00

-171.72 8067.36 8751.47

-1705.40 22.0 283895.00

-451199.00 356261.00

-175.40 8389.72 8926.87

-1890.66 24.0 288388.00

-437401.00 323902.00

-164.80 8075.31 9968.86

-1575.02 26.0 299757.00

-459004.00 349014.00

-154.15 7793.16 11086.10

-1690.60 28.0 312233.00

-487890.00 389532.00

-156.41 8001.62 11248.70

-1695.28 30.0 317451.00

-470929.00 352843.00

-144.12 7616.90 12129.50

-1519.49 35.0 340908.00

-472938.00 320383.00

-126.33 6958.19 14189.40

-1265.87 40.0 355826.00

-406707.00 181832.00

-109.88 6567.54 13350.90

-690.33

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-70 Table 2.4-4 (Page 9 of 10)

BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 10x10A/B/G A

B C

D E

F G

2.0 16284.00 11316.60

-2373.42

-183.95 4757.49

-1129.72

-908.53 2.25 21494.10 11161.90

-2738.06

-174.87 5233.98

-1435.08

-1029.88 2.5 27378.90 10122.70

-3001.13

-163.37 5590.72

-1687.18

-1133.76 2.75 33997.50 7667.21

-2796.85

-154.59 5934.47

-1960.21

-1063.93 3.0 40669.30 4604.85

-2427.68

-146.64 6233.46

-2224.40

-1023.08 4.0 69456.60

-19048.60 4510.80

-121.07 6769.53

-2693.26

-595.32 5.0 96363.50

-53810.50 20060.80

-115.15 6852.01

-2455.28

-235.29 6.0 118075.00

-89649.00 40101.30

-135.03 7207.34

-2199.03

-31.82 7.0 135465.00

-121448.00 59891.00

-141.81 7176.22

-1464.52

-84.35 8.0 149172.00

-147759.00 77477.10

-146.29 7123.94

-720.75

-270.69 9.0 160098.00

-171854.00 96698.30

-168.49 7716.07

-861.33

-341.94 10.0 168703.00

-188210.00 108590.00

-170.65 7707.01

-369.98

-413.26 11.0 176895.00

-205123.00 122221.00

-167.56 7590.63 267.07

-597.28 12.0 183500.00

-217775.00 132403.00

-165.29 7503.92 748.16

-696.44 13.0 189527.00

-229054.00 141757.00

-162.77 7481.92 1050.96

-848.98 14.0 195892.00

-241671.00 152138.00

-155.37 7192.81 1854.09

-983.23 15.0 199561.00

-249322.00 161820.00

-172.75 7962.69 824.80

-863.19 16.0 204447.00

-258563.00 171271.00

-167.33 7839.02 1163.01

-928.77 17.0 209187.00

-266807.00 178586.00

-160.49 7588.94 1870.46

-983.28 18.0 212908.00

-270532.00 180865.00

-155.48 7487.99 2077.63

-955.84 19.0 216478.00

-274912.00 185127.00

-150.92 7417.63 2302.50

-949.30 20.0 219761.00

-276790.00 185299.00

-144.53 7207.71 2794.21

-860.04 22.0 230330.00

-297894.00 208958.00

-142.95 7317.84 2710.62

-1141.54 24.0 235204.00

-296597.00 207242.00

-136.96 7299.78 2658.68

-881.02 26.0 243035.00

-302622.00 210474.00

-120.72 6753.85 3686.66

-891.14 28.0 250446.00

-307503.00 216130.00

-107.51 6366.92 4185.55

-863.84 30.0 265199.00

-348982.00 280458.00

-107.22 6539.80 3562.03

-1192.36 35.0 273468.00

-298369.00 203934.00

-79.97 5875.23 3082.40

-627.85 40.0 292898.00

-285148.00 187876.00

-50.41 4835.07 2436.15

-509.94

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-71 Table 2.4-4 (Page 10 of 10)

BWR Fuel Assembly Cooling Time-Dependent Coefficients (ZR-Clad Fuel)

Cooling Time (years)

Array/Class 10x10C A

B C

D E

F G

2.0 17325.30 11490.30

-2423.96

-183.30 5030.60

-1243.75

-1042.41 2.25 22130.00 11951.30

-2993.28

-179.73 5638.45

-1641.98

-1049.38 2.5 28141.40 10893.00

-3249.42

-171.97 6092.80

-1970.42

-1042.25 2.75 35001.90 8485.77

-3132.08

-161.49 6464.02

-2288.54

-1064.03 3.0 41817.40 5588.18

-2935.15

-152.37 6778.27

-2580.33

-960.42 4.0 72503.80

-20126.90 4676.40

-126.12 7389.26

-3161.51

-598.75 5.0 101686.00

-58844.80 22172.30

-118.88 7430.83

-2824.08

-314.90 6.0 125964.00

-100714.00 46115.40

-137.38 7670.65

-2280.40

-139.13 7.0 145279.00

-138063.00 69971.00

-145.81 7593.29

-1239.47

-240.17 8.0 160736.00

-171770.00 94922.90

-169.48 8074.18

-936.98

-413.14 9.0 173109.00

-198050.00 114195.00

-173.24 7952.04 107.22

-587.69 10.0 183348.00

-219689.00 130706.00

-174.38 7886.25 887.26

-747.19 11.0 192349.00

-239413.00 146643.00

-173.03 7738.68 1801.89

-960.79 12.0 198722.00

-251849.00 156661.00

-174.40 7779.41 2247.21

-1024.32 13.0 206317.00

-271870.00 177242.00

-191.21 8405.58 1825.60

-1138.70 14.0 212647.00

-284224.00 187282.00

-183.63 8103.28 2759.09

-1219.61 15.0 218920.00

-297923.00 200391.00

-179.50 7978.82 3335.37

-1313.57 16.0 223379.00

-304963.00 206476.00

-175.76 7922.23 3689.54

-1328.16 17.0 228676.00

-314595.00 214380.00

-168.29 7569.76 4728.35

-1384.57 18.0 233175.00

-321606.00 220636.00

-164.63 7582.84 4872.65

-1394.73 19.0 238334.00

-334048.00 236292.00

-170.69 7886.97 4618.40

-1403.78 20.0 242429.00

-340497.00 242818.00

-172.36 8094.92 4434.37

-1437.97 22.0 251428.00

-353397.00 253878.00

-156.59 7500.41 6060.21

-1412.04 24.0 257957.00

-354461.00 249954.00

-147.71 7305.10 6634.39

-1346.94 26.0 272010.00

-391459.00 299301.00

-145.25 7227.25 7258.81

-1619.05 28.0 273995.00

-368436.00 261102.00

-136.90 7071.78 7562.48

-1159.20 30.0 279666.00

-356857.00 232864.00

-125.34 6696.43 8273.08

-973.58 35.0 297242.00

-340805.00 191056.00

-108.66 6404.77 8127.91

-777.55 40.0 330405.00

-398218.00 299749.00

-84.01 5531.03 7980.06

-1232.79

Approved Contents 2.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 2-72 1

2 0.5*

0.5*

3 4

5 6

7 8

0.5*

0.5 1.2 1.2 0.5 0.5*

9 10 11 12 13 14 15 16 0.5*

0.5 1.2 0.4 0.4 1.2 0.5 0.5*

17 18 19 20 21 22 23 24 0.5 1.2 0.4 0.4 0.4 0.4 1.2 0.5 25 26 27 28 29 30 31 32 33 34 0.5*

1.2 0.4 0.4 0.4 0.4 0.4 0.4 1.2 0.5*

35 36 37 38 39 40 41 42 43 44 0.5*

1.2 0.4 0.4 0.4 0.4 0.4 0.4 1.2 0.5*

45 46 47 48 49 50 51 52 0.5 1.2 0.4 0.4 0.4 0.4 1.2 0.5 53 54 55 56 57 58 59 60 0.5*

0.5 1.2 0.4 0.4 1.2 0.5 0.5*

61 62 63 64 65 66 0.5*

0.5 1.2 1.2 0.5 0.5*

Cell ID 67 68 Heat Load (kW) 0.5*

0.5*

  • When DAMAGED FUEL or FUEL DEBRIS is stored in this location (in a DFC), the allowable heat load of the cell is limited to 0.35 kW Figure 2.4-1 Per Cell Allowable Heat Loads (kW) - MPC-68M

Design Features 3.0 Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-1 3.0 DESIGN FEATURES 3.1 Site 3.1.1 Site Location The HI-STORM 100 Cask System is authorized for general use by 10 CFR Part 50 license holders at various site locations under the provisions of 10 CFR 72, Subpart K.

3.2 Design Features Important for Criticality Control 3.2.1 MPC-24

1.

Flux trap size: 1.09 in.

2.

10B loading in the neutron absorbers: 0.0267 g/cm2 (Boral) and 0.0223 g/cm2 (METAMIC) 3.2.2 MPC-68 and MPC-68FF

1.

Fuel cell pitch: 6.43 in.

2.

10B loading in the neutron absorbers: 0.0372 g/cm2 (Boral) and 0.0310 g/cm2 (METAMIC) 3.2.3 MPC-68F

1.

Fuel cell pitch: 6.43 in.

2.

10B loading in the Boral neutron absorbers: 0.01 g/cm2 3.2.4 MPC-24E and MPC-24EF

1.

Flux trap size:

i. Cells 3, 6, 19, and 22: 0.776 inch ii. All Other Cells: 1.076 inches
2.

10B loading in the neutron absorbers: 0.0372 g/cm2 (Boral) and 0.0310 g/cm2 (METAMIC) 3.2.5 MPC-32 and MPC-32F

1.

Fuel cell pitch: 9.158 inches

2.

10B loading in the neutron absorbers: 0.0372 g/cm2 (Boral) and 0.0310 g/cm2 (METAMIC)

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-2 3.2 Design features Important for Criticality Control (contd) 3.2.6 MPC-68M

1. Basket Cell wall thickness 0.4 in. (nom.)
2. B4C content in METAMIC-HT shall be 10 wt. %

3.2.7 Fuel spacers shall be sized to ensure that the active fuel region of intact or undamaged fuel assemblies remains within the neutron poison region of the MPC basket with water in the MPC.

3.2.8 The B4C content in METAMIC shall be 33.0 wt.%.

3.2.9 Neutron Absorber Tests Boral and Metamic Classic Section 9.1.5.3 of the HI-STORM 100 FSAR is hereby incorporated by reference into the HI-STORM 100 CoC. For each MPC model specified in Sections 3.2.1 through 3.2.5 above, the neutron absorber shall meet the minimum requirements for 10B areal density or B4C content, as applicable.

Metamic-HT (Section 3.2.6 above)

1. The weight percentage of the boron carbide must be confirmed to be greater than or equal to 10% in each lot of Al/B4C powder.
2. The areal density of the B-10 isotope corresponding to the 10% min.

weight density in the manufactured Metamic-HT panels shall be independently confirmed by the neutron attenuation test method by testing at least one coupon from a randomly selected panel in each lot.

3. If the B-10 areal density criterion in the tested panels fails to meet the specific minimum, then the manufacturer has the option to reject the entire lot or to test a statistically significant number of panels and perform statistical analysis for acceptance.
4. All test procedures used in demonstrating compliance with the above requirements shall conform to the cask designers QA program which has been approved by the USNRC under docket number 71-0784.

3.3 Codes and Standards The American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code), 1995 Edition with Addenda through 1997, is the governing Code for the HI-STORM 100 System MPCs, OVERPACKs, and TRANSFER CASKs, as clarified in Specification 3.3.1 below, except for Code Sections V and IX. The latest effective editions of ASME Code Sections V and IX, including addenda, may be used for activities governed by those sections, provided a written reconciliation of the later edition against the 1995 Edition, including addenda, is performed by the certificate holder. American Concrete Institute (ACI) 349-85 is the governing Code for plain concrete as clarified in Appendix 1.D of the Final Safety Analysis Report for the HI-STORM 100 Cask System.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-3 3.3.1 Alternatives to Codes, Standards, and Criteria Table 3-1 lists approved alternatives to the ASME Code for the design of the MPCs, OVERPACKs, and TRANSFER CASKs of the HI-STORM 100 Cask System.

3.3.2 Construction/Fabrication Alternatives to Codes, Standards, and Criteria Proposed alternatives to the ASME Code, Sections II and III, 1995 Edition with Addenda through 1997 including modifications to the alternatives allowed by Specification 3.3.1 may be used on a case-specific basis when authorized by the Director of the Office of Nuclear Material Safety and Safeguards or designee. The request for such alternative should demonstrate that:

1.

The proposed alternatives would provide an acceptable level of quality and safety, or

2.

Compliance with the specified requirements of the ASME Code,Section III, 1995 Edition with Addenda through 1997, would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.

Requests for alternatives shall be submitted in accordance with 10 CFR 72.4.

(continued)

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-4 Table 3-1 (page 1 of 9)

LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC, MPC basket

assembly, HI-STORM OVERPACK steel structure, and HI-TRAC TRANSFER CASK steel structure Subsection NCA General Requirements.

Requires preparation of a Design Specification, Design Report, Overpressure Protection Report, Certification of Construction Report, Data Report, and other administrative controls for an ASME Code stamped vessel.

Because the

MPC, OVERPACK, and TRANSFER CASK are not ASME Code stamped vessels, none of the specifications, reports, certificates, or other general requirements specified by NCA are required. In lieu of a Design Specification and Design Report, the HI-STORM FSAR includes the design criteria, service conditions, and load combinations for the design and operation of the HI-STORM 100 System as well as the results of the stress analyses to demonstrate that applicable Code stress limits are met. Additionally, the fabricator is not required to have an ASME-certified QA program.

All important-to-safety activities are governed by the NRC-approved Holtec QA program.

Because the cask components are not certified to the Code, the terms Certificate Holder and Inspector are not germane to the manufacturing of NRC-certified cask components. To eliminate ambiguity, the responsibilities assigned to the Certificate Holder in the various articles of Subsections NB, NG, and NF of the Code, as applicable, shall be interpreted to apply to the NRC Certificate of Compliance (CoC) holder (and by extension, to the component fabricator) if the requirement must be fulfilled. The Code term Inspector means the QA/QC personnel of the CoC holder and its vendors assigned to oversee and inspect the manufacturing process.

MPC NB-1100 Statement of requirements for Code stamping of components.

MPC enclosure vessel is designed and will be fabricated in accordance with ASME Code,Section III, Subsection NB to the maximum practical extent, but Code stamping is not required.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-5 Table 3-1 (page 2 of 9)

LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC basket supports and lift lugs NB-1130 NB-1132.2(d) requires that the first connecting weld of a nonpressure-retaining structural attachment to a component shall be considered part of the component unless the weld is more than 2t from the pressure-retaining portion of the component, where t is the nominal thickness of the pressure-retaining material.

NB-1132.2(e) requires that the first connecting weld of a welded nonstructural attachment to a component shall conform to NB-4430 if the connecting weld is within 2t from the pressure-retaining portion of the component.

The MPC basket supports (nonpressure-retaining structural attachments)and lift lugs (nonstructural attachments (relative to the function of lifting a loaded MPC) that are used exclusively for lifting an empty MPC) are welded to the inside of the pressure-retaining MPC shell, but are not designed in accordance with Subsection NB. The basket supports and associated attachment welds are designed to satisfy the stress limits of Subsection NG and the lift lugs and associated attachment welds are designed to satisfy the stress limits of Subsection NF, as a minimum. These attachments and their welds are shown by analysis to meet the respective stress limits for their service conditions. Likewise, non-structural items, such as shield plugs, spacers, etc. if used, can be attached to pressure-retaining parts in the same manner.

MPC NB-2000 Requires materials to be supplied by ASME-approved material supplier.

Materials will be supplied by Holtec-approved suppliers with Certified Material Test Reports (CMTRs) in accordance with NB-2000 requirements.

MPC NB-2121 Provides permitted material specification for pressure-retaining material, which must conform to Section II, Part D, Tables 2A and 2B Certain duplex stainless steels are not included in Section II, Part D, Tables 2A and 2B. UNS S31803 duplex stainless steel alloy is evaluated in the HI-STORM 100 FSAR and meets the required design criteria for use in the HI-STORM 100 system per ASME Code Case N-635-1.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-6 Table 3-1 (page 3 of 9)

LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC, MPC basket

assembly, HI-STORM OVERPACK and HI-TRAC TRANSFER CASK NB-3100 NG-3100 NF-3100 Provides requirements for determining design loading conditions, such as pressure, temperature, and mechanical loads.

These requirements are not applicable. The HI-STORM FSAR, serving as the Design Specification, establishes the service conditions and load combinations for the storage system.

MPC NB-3350 NB-3352.3 requires, for Category C joints, that the minimum dimensions of the welds and throat thickness shall be as shown in Figure NB-4243-1.

Due to MPC basket-to-shell interface requirements, the MPC shell-to-baseplate weld joint design (designated Category C) does not include a reinforcing fillet weld or a bevel in the MPC baseplate, which makes it different than any of the representative configurations depicted in Figure NB-4243-1. The transverse thickness of this weld is equal to the thickness of the adjoining shell (1/2 inch). The weld is designed as a full penetration weld that receives VT and RT or UT, as well as final surface PT examinations.

Because the MPC shell design thickness is considerably larger than the minimum thickness required by the Code, a reinforcing fillet weld that would intrude into the MPC cavity space is not included. Not including this fillet weld provides for a higher quality radiographic examination of the full penetration weld.

From the standpoint of stress analysis, the fillet weld serves to reduce the local bending stress (secondary stress) produced by the gross structural discontinuity defined by the flat plate/shell junction. In the MPC design, the shell and baseplate thicknesses are well beyond that required to meet their respective membrane stress intensity limits.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-7 Table 3-1 (page 4 of 9)

LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC, MPC Basket

Assembly, HI-STORM OVERPACK steel structure, and HI-TRAC TRANSFER CASK steel structure NB-4120 NG-4120 NF-4120 NB-4121.2, NG-4121.2, and NF-4121.2 provide requirements for repetition of tensile or impact tests for material subjected to heat treatment during fabrication or installation.

In-shop operations of short duration that apply heat to a component, such as plasma cutting of plate stock, welding, machining, coating, and pouring of lead are not, unless explicitly stated by the Code, defined as heat treatment operations.

For the steel parts in the HI-STORM 100 System components, the duration for which a part exceeds the off-normal temperature limit defined in Chapter 2 of the FSAR shall be limited to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in a particular manufacturing process (such as the HI-TRAC lead pouring process).

MPC, MPC basket

assembly, HI-STORM OVERPACK steel structure, and HI-TRAC TRANSFER CASK steel structure NB-4220 NF-4220 Requires certain forming tolerances to be met for cylindrical, conical, or spherical shells of a vessel.

The cylindricity measurements on the rolled shells are not specifically recorded in the shop travelers, as would be the case for a Code-stamped pressure vessel. Rather, the requirements on inter-component clearances (such as the MPC-to-TRANSFER CASK) are guaranteed through fixture-controlled manufacturing. The fabrication specification and shop procedures ensure that all dimensional design objectives, including inter-component annular clearances are satisfied.

The dimensions required to be met in fabrication are chosen to meet the functional requirements of the dry storage components. Thus, although the post-forming Code cylindricity requirements are not evaluated for compliance directly, they are indirectly satisfied (actually exceeded) in the final manufactured components.

MPC Lid and Closure Ring Welds NB-4243 Full penetration welds required for Category C Joints (flat head to main shell per NB-3352.3).

MPC lid and closure ring are not full penetration welds. They are welded independently to provide a redundant seal. Additionally, a weld efficiency factor of 0.45 has been applied to the analyses of these welds.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-8 Table 3-1 (page 5 of 9)

LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC Lid to Shell Weld NB-5230 Radiographic (RT) or ultrasonic (UT) examination required Only UT or multi-layer liquid penetrant (PT) examination is permitted. If PT alone is used, at a minimum, it will include the root and final weld layers and each approximately 3/8 inch of weld depth.

MPC Closure Ring, Vent and Drain Cover Plate Welds NB-5230 Radiographic (RT) or ultrasonic (UT) examination required Root (if more than one weld pass is required) and final liquid penetrant examination to be performed in accordance with NB-5245. The closure ring provides independent redundant closure for vent and drain cover plates.

MPC Enclosure Vessel and Lid NB-6111 All completed pressure retaining systems shall be pressure tested.

The MPC enclosure vessel is seal welded in the field following fuel assembly loading. The MPC enclosure vessel shall then be pressure tested as defined in Chapter 9. Accessibility for leakage inspections precludes a Code compliant pressure test. Since the shell welds of the MPC cannot be checked for leakage during this pressure test, the shop leakage test to 10-7 ref-cc/sec provides reasonable assurance as to its leak tightness. All MPC enclosure vessel welds (except closure ring and vent/drain cover plate) are inspected by volumetric examination, except the MPC lid-to-shell weld shall be verified by volumetric or multi-layer PT examination. If PT alone is used, at a minimum, it must include the root and final layers and each approximately 3/8 inch of weld depth. For either UT or PT, the maximum undetectable flaw size must be demonstrated to be less than the critical flaw size. The critical flaw size must be determined in accordance with ASME Section XI methods.

The critical flaw size shall not cause the primary stress limits of NB-3000 to be exceeded.

The inspection results, including relevant findings (indications), shall be made a permanent part of the users records by video, photographic, or other means which provide an equivalent retrievable record of weld integrity.

The video or photographic records should be taken during the final interpretation period described in ASME Section V, Article 6, T-676.

The vent/drain cover plate and the closure ring welds are confirmed by liquid penetrant examination. The inspection of the weld must be performed by qualified personnel and shall meet the acceptance requirements of ASME Code Section III, NB-5350 for PT or NB-5332 for UT.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-9 Table 3-1 (page 6 of 9)

LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC Enclosure Vessel NB-7000 Vessels are required to have overpressure protection No overpressure protection is provided. The function of the MPC enclosure vessel is to contain the radioactive contents under normal, off-normal, and accident conditions. The MPC vessel is designed to withstand maximum internal pressure considering 100% fuel rod failure and maximum accident temperatures.

MPC Enclosure Vessel NB-8000 States requirements for nameplates, stamping and reports per NCA-8000.

The HI-STORM100 System is to be marked and identified in accordance with 10CFR71 and 10CFR72 requirements. Code stamping is not required. QA data package to be in accordance with Holtec approved QA program.

MPC Basket Assembly NG-2000 Requires materials to be supplied by ASME-approved material supplier.

Materials will be supplied by Holtec-approved supplier with CMTRs in accordance with NG-2000 requirements.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-10 Table 3-1 (page 7 of 9)

LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures MPC basket assembly NG-4420 NG-4427(a) allows a fillet weld in any single continuous weld to be less than the specified fillet weld dimension by not more than 1/16 inch, provided that the total undersize portion of the weld does not exceed 10 percent of the length of the weld.

Individual undersize weld portions shall not exceed 2 inches in length.

Modify the Code requirement (intended for core support structures) with the following text prepared to accord with the geometry and stress analysis imperatives for the fuel basket: For the longitudinal MPC basket fillet welds, the following criteria apply: 1) The specified fillet weld throat dimension must be maintained over at least 92 percent of the total weld length. All regions of undersized weld must be less than 3 inches long and separated from each other by at least 9 inches. 2) Areas of undercuts and porosity beyond that allowed by the applicable ASME Code shall not exceed 1/2 inch in weld length.

The total length of undercut and porosity over any 1-foot length shall not exceed 2 inches. 3) The total weld length in which items (1) and (2) apply shall not exceed a total of 10 percent of the overall weld length. The limited access of the MPC basket panel longitudinal fillet welds makes it difficult to perform effective repairs of these welds and creates the potential for causing additional damage to the basket assembly (e.g.,

to the neutron absorber and its sheathing) if repairs are attempted. The acceptance criteria provided in the foregoing have been established to comport with the objectives of the basket design and preserve the margins demonstrated in the supporting stress analysis.

From the structural standpoint, the weld acceptance criteria are established to ensure that any departure from the ideal, continuous fillet weld seam would not alter the primary bending stresses on which the design of the fuel baskets is predicated. Stated differently, the permitted weld discontinuities are limited in size to ensure that they remain classifiable as local stress elevators (peak stress, F, in the ASME Code for which specific stress intensity limits do not apply).

MPC Basket Assembly NG-8000 States requirements for nameplates, stamping and reports per NCA-8000.

The HI-STORM100 System is to be marked and identified in accordance with 10CFR71 and 10CFR72 requirements. Code stamping is not required. The MPC basket data package to be in accordance with Holtec approved QA program.

OVERPACK Steel Structure NF-2000 Requires materials to be supplied by ASME-approved material supplier.

Materials will be supplied by Holtec-approved supplier with CMTRs in accordance with NF-2000 requirements.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-11 Table 3-1 (page 8 of 9)

LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures TRANSFER CASK Steel Structure NF-2000 Requires materials to be supplied by ASME-approved material supplier.

Materials will be supplied by Holtec-approved supplier with CMTRs in accordance with NF-2000 requirements.

OVERPACK Baseplate and Lid Top Plate NF-4441 Requires special examinations or requirements for welds where a primary member of thickness 1 inch or greater is loaded to transmit loads in the through thickness direction.

The margins of safety in these welds under loads experienced during lifting operations or accident conditions are quite large. The OVERPACK baseplate welds to the inner shell, pedestal shell, and radial plates are only loaded during lifting conditions and have large safety factors during lifting. Likewise, the top lid plate to lid shell weld has a large structural margin under the inertia loads imposed during a non-mechanistic tipover event.

OVERPACK Steel Structure NF-3256 NF-3266 Provides requirements for welded joints.

Welds for which no structural credit is taken are identified as Non-NF welds in the design drawings. These non-structural welds are specified in accordance with the pre-qualified welds of AWS D1.1. These welds shall be made by welders and weld procedures qualified in accordance with AWS D1.1 or ASME Section IX.

Welds for which structural credit is taken in the safety analyses shall meet the stress limits for NF-3256.2, but are not required to meet the joint configuration requirements specified in these Code articles. The geometry of the joint designs in the cask structures are based on the fabricability and accessibility of the joint, not generally contemplated by this Code section governing supports.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-12 Table 3-1 (page 9 of 9)

LIST OF ASME CODE ALTERNATIVES FOR HI-STORM 100 CASK SYSTEM Component Reference ASME Code Section/Article Code Requirement Alternative, Justification & Compensatory Measures HI-STORM OVERPACK and HI-TRAC TRANSFER CASK NF-3320 NF-4720 NF-3324.6 and NF-4720 provide requirements for bolting These Code requirements are applicable to linear structures wherein bolted joints carry axial, shear, as well as rotational (torsional) loads. The OVERPACK and TRANSFER CASK bolted connections in the structural load path are qualified by design based on the design loadings defined in the FSAR. Bolted joints in these components see no shear or torsional loads under normal storage conditions.

Larger clearances between bolts and holes may be necessary to ensure shear interfaces located elsewhere in the structure engage prior to the bolts experiencing shear loadings (which occur only during side impact scenarios).

Bolted joints that are subject to shear loads in accident conditions are qualified by appropriate stress analysis. Larger bolt-to-hole clearances help ensure more efficient operations in making these bolted connections, thereby minimizing time spent by operations personnel in a radiation area. Additionally, larger bolt-to-hole clearances allow interchangeability of the lids from one particular fabricated cask to another.

HI-STORM OVERPACK and HI-TRAC TRANSFER CASK Section II, SA-516/516A Table 1 -

Chemical requirements All SA-516 material used in the HI-STORM 100 system is required to meet the material composition described in ASME Code Section II, 2007 edition. This edition allows for a different manganese content from the 1995 edition, but does not change the structural or thermal properties of the material.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-13 3.4 Site-Specific Parameters and Analyses Site-specific parameters and analyses that will require verification by the system user are, as a minimum, as follows:

1.

The temperature of 80o F is the maximum average yearly temperature.

2.

The allowed temperature extremes, averaged over a 3-day period, shall be greater than -40o F and less than 125o F.

3.
a.

For storage in freestanding OVERPACKs, the resultant horizontal acceleration (vectorial sum of two horizontal Zero Period Accelerations (ZPAs) at a three-dimensional seismic site), GH, and vertical ZPA, GV, on the top surface of the ISFSI pad, expressed as fractions of g, shall satisfy the following inequality:

GH + µGV µ where µ is either the Coulomb friction coefficient for the cask/ISFSI pad interface or the ratio r/h, where r is the radius of the cask and h is the height of the cask center-of-gravity above the ISFSI pad surface. The above inequality must be met for both definitions of µ,

but only applies to ISFSIs where the casks are deployed in a freestanding configuration. Unless demonstrated by appropriate testing that a higher coefficient of friction value is appropriate for a specific ISFSI, the value used shall be 0.53. If acceleration time-histories on the ISFSI pad surface are available, GH and GV may be the coincident values of the instantaneous net horizontal and vertical accelerations. If instantaneous accelerations are used, the inequality shall be evaluated at each time step in the acceleration time history over the total duration of the seismic event.

If this static equilibrium based inequality cannot be met, a dynamic analysis of the cask/ISFSI pad assemblage with appropriate recognition of soil/structure interaction effects shall be performed to ensure that the casks will not tip over or undergo excessive sliding under the sites Design Basis Earthquake.

(continued)

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-14 3.4 Site-Specific Parameters and Analyses (continued)

b. For free-standing casks, under environmental conditions that may degrade the pad/cask interface friction (such as due to icing) the response of the casks under the sites Design Basis Earthquake shall be established using the best estimate of the friction coefficient in an appropriate analysis model. The analysis should demonstrate that the earthquake will not result in cask tipover or cause a cask to fall off the pad. In addition, impact between casks should be precluded, or should be considered an accident for which the maximum g-load experienced by the stored fuel shall be limited to 45 gs.
c.

For those ISFSI sites with design basis seismic acceleration values that may overturn or cause excessive sliding of free-standing casks, the HI-STORM 100 System OVERPACKs shall be anchored to the ISFSI pad. The site seismic characteristics and the anchorage system shall meet the following requirements:

i.

The site acceleration response spectra at the top of the ISFSI pad shall have ZPAs that meet the following inequalities:

GH 2.12 AND GV 1.5 Where:

GH is the vectorial sum of the two horizontal ZPAs at a three-dimensional seismic site (or the horizontal ZPA at a two-dimensional site) and GV is the vertical ZPA.

ii.

Each HI-STORM 100 dry storage cask shall be anchored with twenty-eight (28), 2-inch diameter studs and compatible nuts of material suitable for the expected ISFSI environment. The studs shall meet the following requirements:

Yield Strength at Ambient Temperature: 80 ksi Ultimate Strength at Ambient Temperature: 125 ksi Initial Tensile Pre-Stress: 55 ksi AND 65 ksi (continued)

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-15 3.4 Site-Specific Parameters and Analyses (continued)

NOTE:

The above anchorage specifications are required for the seismic spectra defined in item 3.4.3.c.i. Users may use fewer studs or those of different diameter to account for site-specific seismic spectra less severe than those specified above. The embedment design shall comply with Appendix B of ACI-349-97. A later edition of this Code may be used, provided a written reconciliation is performed.

iii. Embedment Concrete Compressive Strength: 4,000 psi at 28 days

4.

The analyzed flood condition of 15 fps water velocity and a height of 125 feet of water (full submergence of the loaded cask) are not exceeded.

5.

The potential for fire and explosion while handling a loaded OVERPACK or TRANSFER CASK shall be addressed, based on site-specific considerations. The user shall demonstrate that the site-specific potential for fire is bounded by the fire conditions analyzed by the Certificate Holder, or an analysis of the site-specific fire considerations shall be performed.

6.
a.

For freestanding casks, the ISFSI pad shall be verified by analysis to limit cask deceleration during design basis drop and non-mechanistic tip-over events to 45 gs at the top of the MPC fuel basket. Analyses shall be performed using methodologies consistent with those described in the HI-STORM 100 FSAR. A restriction on the lift and/or drop height is not required if the cask is lifted with a device designed in accordance with applicable stress limits from ANSI N14.6, and/or NUREG-0612, and has redundant drop protection features.

b.

For anchored casks, the ISFSI pad shall be designed to meet the embedment requirements of the anchorage design. A cask tip-over event for an anchored cask is not credible. The ISFSI pad shall be verified by analysis to limit cask deceleration during a design basis drop event to 45 gs at the top of the MPC fuel basket, except as provided for in this paragraph below. Analyses shall be performed using methodologies consistent with those described in the HI-STORM 100 FSAR. A restriction on the lift and/or drop height is not required to be established if the cask is lifted with a device designed in accordance with applicable stress limits from ANSI N14.6, and/or NUREG-0612, and has redundant drop protection features.

(continued)

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-16 3.4 Site-Specific Parameters and Analyses (continued)

7.

In cases where engineered features (i.e., berms and shield walls) are used to ensure that the requirements of 10CFR72.104(a) are met, such features are to be considered important to safety and must be evaluated to determine the applicable quality assurance category.

8.

LOADING OPERATIONS, TRANSPORT OPERATIONS, and UNLOADING OPERATIONS shall only be conducted with working area ambient temperatures 0o F for all MPC heat loads, and

a.

90oF (averaged over a 3-day period) for operations subjected to direct solar heating

b.

110oF (averaged over a 3-day period) for operations not subjected to direct solar heating for all MPC heat loads.

9.

For those users whose site-specific design basis includes an event or events (e.g., flood) that result in the blockage of any OVERPACK inlet or outlet air ducts for an extended period of time (i.e, longer than the total Completion Time of LCO 3.1.2), an analysis or evaluation may be performed to demonstrate adequate heat removal is available for the duration of the event. Adequate heat removal is defined as fuel cladding temperatures remaining below the short term temperature limit. If the analysis or evaluation is not performed, or if fuel cladding temperature limits are unable to be demonstrated by analysis or evaluation to remain below the short term temperature limit for the duration of the event, provisions shall be established to provide alternate means of cooling to accomplish this objective.

10.

Users shall establish procedural and/or mechanical barriers to ensure that during LOADING OPERATIONS and UNLOADING OPERATIONS, either the fuel cladding is covered by water, or the MPC is filled with an inert gas.

11.

Site ambient temperature under HI-TRAC TRANSPORT OPERATIONS shall be evaluated in accordance with Section 3.9 requirements.

(continued)

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-17 3.5 Cask Transfer Facility (CTF) 3.5.1 TRANSFER CASK and MPC Lifters Lifting of a loaded TRANSFER CASK and MPC using devices that are not integral to structures governed by 10 CFR Part 50 shall be performed with a CTF that is designed, operated, fabricated, tested, inspected, and maintained in accordance with the guidelines of NUREG-0612, Control of Heavy Loads at Nuclear Power Plants, as applicable, and the below clarifications. The CTF Structure requirements below do not apply to heavy loads bounded by the regulations of 10 CFR Part 50 or to the loading of an OVERPACK in a belowground restraint system which permits MPC TRANSFER near grade level and does not require an aboveground CTF.

3.5.2 CTF Structure Requirements 3.5.2.1 Cask Transfer Station and Stationary Lifting Devices

1.

The metal weldment structure of the CTF structure shall be designed to comply with the stress limits of ASME Section III, Subsection NF, Class 3 for linear structures. The applicable loads, load combinations, and associated service condition definitions are provided in Table 3-2. All compression loaded members shall satisfy the buckling criteria of ASME Section III, Subsection NF.

2.

If a portion of the CTF structure is constructed of reinforced concrete, then the factored load combinations set forth in ACI-318 (89) for the loads defined in Table 3-2 shall apply.

3.

The TRANSFER CASK and MPC lifting device used with the CTF shall be designed, fabricated, operated, tested, inspected and maintained in accordance with NUREG-0612, Section 5.1.

4.

The CTF shall be designed, constructed, and evaluated to ensure that if the MPC is dropped during inter-cask transfer operations, its confinement boundary would not be breached. This requirement applies to CTFs with either stationary or mobile lifting devices.

(continued)

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-18 3.5 Cask Transfer Facility (CTF) (continued) 3.5.2.2 Mobile Lift Devices If a mobile lifting device is used as the lifting device, in lieu of a stationary lifting device, it shall meet the guidelines of NUREG-0612, Section 5.1, with the following clarifications:

1. Mobile lifting devices shall have a minimum safety factor of two over the allowable load table for the lifting device in accordance with the guidance of NUREG-0612, Section 5.1.6(1)(a) and shall be capable of stopping and holding the load during a Design Basis Earthquake (DBE) event.
2. Mobile lifting devices shall conform to meet the requirements of ANSI B30.5, Mobile and Locomotive Cranes, in lieu of the requirements of ANSI B30.2, Overhead and Gantry Cranes.
3. Mobile cranes are not required to meet the requirements of NUREG-0612, Section 5.1.6(2) for new cranes.
4. Horizontal movements of the TRANSFER CASK and MPC using a mobile crane are prohibited.

(continued)

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-19 3.5 Cask Transfer Facility (CTF)(continued)

Table 3-2 Load Combinations and Service Condition Definitions for the CTF Structure (Note 1)

Load Combination ASME III Service Condition for Definition of Allowable Stress Comment D*

D + S Level A All primary load bearing members must satisfy Level A stress limits D + M + W (Note 2)

D + F D + E D + Y Level D Factor of safety against overturning shall be 1.1 D = Dead load D* = Apparent dead load S = Snow and ice load for the CTF site M = Tornado missile load for the CTF site W = Tornado wind load for the CTF site F = Flood load for the CTF site E = Seismic load for the CTF site Y = Tsunami load for the CTF site Notes:

1.

The reinforced concrete portion of the CTF structure shall also meet the factored combinations of loads set forth in ACI-318(89).

2.

Tornado missile load may be reduced or eliminated based on a PRA for the CTF site.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-20 3.6 Forced Helium Dehydration System 3.6.1

System Description

Use of a forced helium dehydration (FHD) system, (a closed-loop system) is an alternative to vacuum drying the MPC for moderate burnup fuel (

45,000 MWD/MTU) with lower MPC heat load and mandatory for drying MPCs containing one or more high burnup fuel assemblies or higher MPC heat loads as indicated in Appendix A Table 3-1. The FHD system shall be designed for normal operation (i.e., excluding startup and shutdown ramps) in accordance with the criteria in Section 3.6.2.

3.6.2 Design Criteria 3.6.2.1 The temperature of the helium gas in the MPC shall be at least 15oF higher than the saturation temperature at coincident pressure.

3.6.2.2 The pressure in the MPC cavity space shall be 60.3 psig (75 psia) during drying. Backfill pressures shall be as described in Appendix A.

3.6.2.3 The hourly recirculation rate of helium shall be 10 times the nominal helium mass backfilled into the MPC for fuel storage operations.

3.6.2.4 The partial pressure of the water vapor in the MPC cavity will not exceed 3 torr. The limit is met if the gas temperature at the demoisturizer outlet is verified by measurement to remain 21oF for a period of 30 minutes or if the dew point of the gas exiting the MPC is verified by measurement to remain 22.9oF for 30 minutes.

3.6.2.5 The condensing module shall be designed to de-vaporize the recirculating helium gas to a dew point 120oF.

3.6.2.6 The demoisturizing module shall be configured to be introduced into its helium conditioning function after the condensing module has been operated for the required length of time to assure that the bulk moisture vaporization in the MPC (defined as Phase 1 in FSAR Appendix 2.B) has been completed.

3.6.2.7 The helium circulator shall be sized to effect the minimum flow rate of circulation required by these design criteria.

3.6.2.8 The pre-heater module shall be engineered to ensure that the temperature of the helium gas in the MPC meets these design criteria.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-21 3.6 Forced Helium Dehydration System (continued) 3.6.3 Fuel Cladding Temperature A steady-state thermal analysis of the MPC under the forced helium flow scenario shall be performed using the methodology described in HI-STORM 100 FSAR Section 4.4, with due recognition of the forced convection process during FHD system operation. This analysis shall demonstrate that the peak temperature of the fuel cladding, under the most adverse condition of FHD system operation, is below the peak cladding temperature limit for normal conditions of storage for the applicable fuel type (PWR or BWR) and cooling time at the start of dry storage.

3.6.4 Pressure Monitoring During FHD Malfunction During an FHD malfunction event, described in HI-STORM 100 FSAR Chapter 11 as a loss of helium circulation, the system pressure must be monitored to ensure that the conditions listed therein are met.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-22 3.7 Supplemental Cooling System 3.7.1

System Description

A supplemental cooling system (SCS) is an external system for cooling the MPC inside the HI-TRAC transfer cask during on-site transport. The SCS is required for transport of high burnup fuel under certain heat load conditions defined in Table 3-3. The SCS shall be designed for normal operation (i.e., excluding startup and shutdown ramps) in accordance with the criteria in Section 3.7.2.

3.7.2 Design Criteria 3.7.2.1 Not Used.

3.7.2.2 If water is used as the coolant, the system shall be sized to limit the coolant temperature to below 180ºF under steady-state conditions for the design basis heat load at an ambient air temperature of 110ºF. Any electric motors shall have a backup power supply for uninterrupted operation.

3.7.2.3 The system shall utilize a contamination-free fluid medium in contact with the external surfaces of the MPC and inside surfaces of the HI -TRAC transfer cask to minimize corrosion.

3.7.2.4 All passive components such as tubular heat exchangers, manually operated valves and fittings shall be designed to applicable standards (TEMA, ANSI).

3.7.2.5 The heat dissipation capacity of the SCS shall be equal to or greater than the minimum necessary to ensure that the peak cladding temperature is below 400ºC (752ºF). All heat transfer surfaces in heat exchangers shall be assumed to be fouled to the maximum limits specified in a widely used heat exchange equipment standard such as the Standards of Tubular Exchanger Manufacturers Association.

3.7.2.6 The coolant utilized to extract heat from the MPC shall be high purity water or air. Antifreeze may be used to prevent water from freezing if warranted by operating conditions. (continued)

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-23 3.7 Supplemental Cooling System (continued) 3.7.2.7 All pressure boundaries (as defined in the ASME Boiler and Pressure Vessel Code,Section VIII Division 1) shall have pressure ratings that are greater than the maximum system operating pressure by at least 15 psi.

3.7.2.8 All ASME Code components shall comply with Section VIII Division 1 of the ASME Boiler and Pressure Vessel Code.

3.7.2.9 All gasketed and packed joints shall have a minimum design pressure rating of the pump shut-off pressure plus 15 psi.

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-24 Table 3-3 Requirements for Supplemental Cooling System Criteria for use of SCS Requirement MPC-68M Not required MPC containing one or more high Burnup fuel assemblies (> 45,000 MWD/MTU) and Heat loads more than 90% of maximum permissible heat loads defined in Section 2.4 under higher helium backfill limits in Table 3-2 of Appendix A Yes MPC containing one or more high Burnup fuel assemblies (> 45,000 MWD/MTU) and Heat loads more than 90% of heat load limits in Tables 3-3 or 3-4 of Appendix A under lower helium backfill limits in Table 3-2 of Appendix A Yes

Design Features 3.0 DESIGN FEATURES (continued)

Certificate of Compliance No. 1014 Amendment No. 12 Appendix B 3-25 3.8 Combustible Gas Monitoring During MPC Lid Welding and Cutting During MPC lid-to-shell welding and cutting operations, combustible gas monitoring of the space under the MPC lid is required, to ensure that there is no combustible mixture present.

3.9 Environmental Temperature Requirements Short term operations involving the HI-TRAC transfer cask can be carried out if the reference ambient temperature (three day average around the cask) is below the Threshold Temperature of 110 deg. F ambient temperature, applicable during HI-TRAC transfer operations inside the 10 CFR Part 50 or 10 CFR Part 52 structural boundary and 90 deg. F outside of it. The determination of the Threshold Temperature compliance shall be made based on the best available thermal data for the site.

If the reference ambient temperature exceeds the corresponding Threshold Temperature then a site specific analysis shall be performed using the actual heat load and reference ambient temperature equal to the three day average to ensure that the steady state peak fuel cladding temperature will remain below the 400°C limit. If the peak fuel cladding temperature exceeds 400°C limit then the operation of a Supplemental Cooling System (SCS) in accordance with LCO 3.1.4 is mandatory.

SCS operation is mandatory if site data is not available or if a user elects to deploy Supplemental Cooling in lieu of site ambient temperature evaluation.