Industrial Use Scenario with Open Drinking Water Pathway: An Assessment of Impact on DCGL Values for Surface Soil Technical Support Document No.25-103 Revision 0 Prepared by: ______________________________________________________
Joseph Bisson, Technical Consultant Reviewed by:
William Parish, CHP, Sr. Health Physicist Approved by: ______________________________________________________
Christopher Messier, Sr. Director of Engineering and Strategic Development Radiation Safety & Control Services, Inc 93 Ledge Road, Seabrook, NH 03874 1-800-525-8339 (603) 778-2871 (Outside USA) www.radsafety.com Sept. 26, 2025 k RSCS Rad1at1or Safety & Cortrol Services RSCS Radiation Safety & Control Services
RSCS TSD 25-103 Revision 0 2
Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Contents 1
Introduction........................................................................................................................ 3 2
Input................................................................................................................................... 3 3
Results.............................................................................................................................. 14 4
References........................................................................................................................ 15
RSCS TSD 25-103 Revision 0 3
Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil 1 Introduction This report is an assessment of impact that an open drinking water exposure pathway under the Industrial Use (IU) scenario has on the DCGL values for site soil. A detailed description of the IU scenario and derivation of the input values for the RESRAD-Onsite parameters is provided in ENG-OCS-008 [1].
The IU scenario with an open drinking water pathway is considered a less likely but plausible exposure scenario for the OCNGS site for the following reasons:
The Lacey Ordinance #93-31, which requires the owner the site to connect to the town waterline and discontinue and disconnect any water service from a water well located on his or her property.
The groundwater Classification Exception Area (CEA) delineated across a major portion of the site.
The open drinking water pathway for the IU scenario assumes that (i) Lacy Ordinance #93-31 and CEA delineation are ignored, (ii) untreated contaminated site groundwater is the sole source of drinking water available to the hypothetical receptor (a site industrial worker) while onsite and (iii) the drinking water is drawn from a well located at the downstream edge of the contamination zone (i.e., the point of highest groundwater contamination).
The conceptual hydrological model for this IU scenario has three geological strata: (1) a contaminated zone (CZ), (2) an unsaturated zone (UZ), and (3) a saturated zone (SZ).
RESRAD-Onsite, v7.2, [2] was used to calculate probabilistic annual doses. The open exposure pathways are the following:
Direct external radiation exposure pathway Inhalation exposure pathway Aquatic food ingestion exposure pathway Inadvertent ingestion of contaminated soil Drinking water ingestion 2 Input A site-specific suite of potential radionuclides-of-concern (ROCs) has been identified for the OCNGS site [3]
and is listed in Table 1. RESRAD-Onsite 7.2 automatically accounts for progeny radionuclides with input for several of the ROCs. Progeny radionuclides are also listed in Table 1.
Table 1: Radionuclides of Concern Identified for the OCNGS Site ROC Progeny ROC Progeny Am-241 Np-237, Th-229, U-233 Nb-94 C-14 Ni-63 Cm-243 Ac-227, Am-243, Pa-231, Pu-239, U-235 Np-237 Th-229, U-233 Cm-244 Pu-240, Ra-228, Th-228, Th-232, U-236 Pu-238 Pb-210, Po-210, Ra-226, Th-230, U-234
RSCS TSD 25-103 Revision 0 4
Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Co-60 Pu-239 Ac-227, Pa-231, U-235 Cs-137 Pu-240 Ra-228, Th-228, Th-232, U-236 Eu-152 Gd-152 Pu-241 Am-241, Np-237, Th-229, U-233 Eu-154 Sb-125 Te-125m Fe-55 Sr-90 H-3 Tc-99 Mn-54 The CZ is assumed to be uncovered, equivalent in size to the OCS Protected Area (PA), 124,400 m2. The UZ, SZ, and groundwater are assumed initially uncontaminated. The thickness of the CZ and UZ are as documented in ENG-OCS-008.
Exposure time fractions (from ENG-OCS-008):
Fraction of calendar year the receptor is off-site (no exposure) = 0.77 Fraction of calendar year the receptor is outdoors while at the site (exposure) = 0.2 Fraction of calendar year the receptor is indoors while at the site (exposure) = 0.03 Input values for RESRAD-Onsite parameters and their basis are summarized in Table 2.
Table 2: Input Values for RESRAD-Onsite Parameters Values and Bases for RESRAD-Onsite Parameters for DCGL Calculations Industrial Use Scenario with Drinking Water Pathway Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersa Median/
Mean 1
2 3
4 Soil Concentrations Basic radiation dose limit (mrem/y)
P 3
D 25 10 CFR 20.1402 NR NR NR NR Initial principal radionuclide (pCi/g)
P 2
D 1
Unit Value NR NR NR NR Distribution coefficients (sand soil type assigned to contaminated, unsaturated. and saturated zones) (cm3/g)
Ac-227 P
1 S
Truncated lognormal-n NUREG/CR-7267 7.44 1.1 0.001 0.999 1700 Am-241 P
1 D
S 3.7E+03 (CZ)
Truncated lognormal-n (UZ, SZ) 75th percentile ANL/EVS/TM-14/4 6.91 1.95 0.001 0.999 1000 Am-243 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 6.91 1.95 0.001 0.999 1000 C-14 P
1 D
S 6.2E+00 (UZ)
Truncated lognormal-n (CZ, SZ) 25th percentile NUREG/CR-7267 3.04 1.82 0.001 0.999 21 Cm-243 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 8.13 2.64 0.001 0.999 3400 Cm-244 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 8.13 2.64 0.001 0.999 3400 Co-60 P
1 D
S 1.8E+03 (CZ)
Truncated lognormal-n (UZ, SZ) 75th percentile ANL/EVS/TM-14/4 5.56 2.89 0.001 0.999 260 Cs-137 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 6.27 1.79 0.001 0.999 530 Eu-152 P
1 D
S 1.4E+04 (CZ)
Truncated lognormal-n (UZ,SZ) 75th percentile NUREG/CR-7267 6.86 4.01 0.001 0.999 955
RSCS TSD 25-103 Revision 0 5
Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Values and Bases for RESRAD-Onsite Parameters for DCGL Calculations Industrial Use Scenario with Drinking Water Pathway Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersa Median/
Mean 1
2 3
4 Eu-154 P
1 D
S 1.4E+04 (CZ)
Truncated lognormal-n (UZ,SZ) 75th percentile NUREG/CR-7267 6.86 4.01 0.001 0.999 955 Fe-55 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 5.77 0
0.001 0.999 320 Gd-152 P
1 S
Truncated lognormal-n NUREG/CR-7267 1.61 3.22 0.001 0.999 5
H-3 P
1 D
S 4.3E-02 (CZ)
Truncated lognormal-n (UZ,SZ) 25th percentile NUREG/CR-7267
-2.81 0.5 0.001 0.999 0.06 Mn-54 P
1 D
S 5.8E+03 (CZ)
Truncated lognormal-n (UZ,SZ) 75th percentile ANL/EVS/TM-14/4 6.89 2.64 0.001 0.999 980 Nb-94 P
1 S
Truncated lognormal-n NUREG/CR-7267 7.31 1.39 0.001 0.999 1500 Ni-63 P
1 D
S 6.1E+02 (CZ)
Truncated lognormal-n (UZ,SZ) 75th percentile ANL/EVS/TM-14/4 4.87 2.3 0.001 0.999 130 Np-237 P
1 D
S 3.6E+01 (CZ)
Truncated lognormal-n (UZ, SZ) 75th percentile ANL/EVS/TM-14/4 2.64 1.39 0.001 0.999 14 Pa-231 P
1 S
Truncated lognormal-n NUREG/CR-7267 7.6 1.1 0.001 0.999 2000 Pb-210 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 5.39 1.39 0.001 0.999 220 Po-210 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 4.61 1.79 0.001 0.999 100 Pu-238 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 5.99 1.39 0.001 0.999 400 Pu-239 P
1 D
S 1.0E+03 (CZ) 1.6E+02 (UZ)
Truncated lognormal-n (SZ) 75th percentile 25th percentile ANL/EVS/TM-14/4 5.99 1.39 0.001 0.999 400 Pu-240 P
1 D
D S
1.0E+03 (UZ) 1.6E+02 (SZ)
Truncated lognormal-n (CZ) 75th percentile 25th percentile ANL/EVS/TM-14/4 5.99 1.39 0.001 0.999 400 Pu-241 P
1 D
S 1.0E+03 (CZ)
Truncated lognormal-n (UZ, SZ) 75th percentile ANL/EVS/TM-14/4 5.99 1.39 0.001 0.999 400 Ra-226 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 8.04 2.08 0.001 0.999 3100 Ra-228 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 8.04 2.08 0.001 0.999 3100 Sb-125 P
1 D
S 5.6E+01 (CZ)
Truncated lognormal-n (UZ,SZ) 75th percentile ANL/EVS/TM-14/4 2.83 1.79 0.001 0.999 17 Sr-90 P
1 D
S 7.3E+01 (CZ)
Truncated lognormal-n (UZ.SZ) 75th percentile ANL/EVS/TM-14/4 3.09 1.79 0.001 0.999 22
RSCS TSD 25-103 Revision 0 6
Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Values and Bases for RESRAD-Onsite Parameters for DCGL Calculations Industrial Use Scenario with Drinking Water Pathway Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersa Median/
Mean 1
2 3
4 Tc-99 P
1 D
S 1.9E-02 (UZ)
Truncated lognormal-n (CZ, SZ) 25th percentile ANL/EVS/TM-14/4
-3.22 1.1 0.001 0.999 0.04 Te-125m P
1 S
Truncated lognormal-n NUREG/CR-7267 6.31 3.22 0.001 0.999 550 Th-228 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 6.55 2.4 0.001 0.999 700 Th-229 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 6.55 2.4 0.001 0.999 700 Th-230 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 6.55 2.4 0.001 0.999 700 Th-232 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 6.55 2.4 0.001 0.999 700 U-233 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 4.7 2.48 0.001 0.999 110 U-234 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 4.7 2.48 0.001 0.999 110 U-235 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 4.7 2.48 0.001 0.999 110 U-236 P
1 S
Truncated lognormal-n ANL/EVS/TM-14/4 4.7 2.48 0.001 0.999 110 Initial concentration of radionuclides present in groundwater (pCi/l)
P 3
D 0
Ground water uncontaminated NR NR NR NR Calculation Times Time since placement of material (y)
P 3
D 0
NR NR NR NR Time for calculations (y)
P 3
D 1, 3, 10, 30, 100, 300, 1000 RESRAD Default NR NR NR NR Contaminated Zone Area of contaminated zone (m2)
P 2
D 124,400 OCGS PA NR NR NR NR Thickness of contaminated zone (m)
P 2
D S
3.0E+00 Uniform 75th percentile value assigned to C-14, H-3 Site-specific distribution; assigned to all other ROCs 0.1524 3.96 2.06 Length parallel to aquifer flow (m)
P 2
D 398 Site-specific assumed diameter of a circle with an area = OCGS contaminated zone, 124,400 m2 NR NR NR NR Cover and Contaminated Zone Hydrological Data Cover depth (m)
P 2
D 0
No cover NR NR NR NR Density of contaminated zone (g/cm3)
P 1
S Bounded Normal NUREG/CR-7267 distribution for site soil type - sand.
1.5105 0.159 1.019 2.002 1.5105 Contaminated zone erosion rate (m/y)
P 2
D 6E-04 NUREG/CR-7267; assumed erosion rate for site with shallow slope (i.e.,
relatively level)
NR NR NR NR Contaminated zone total porosity P
2 S
Bounded Normal NUREG/CR-7267 distribution for site soil type - sand 0.43 0.06 0.2446 0.6154 0.43 Contaminated zone field capacity P
3 D
0.18 Value based on site-specific soil type (sand); calculated using equation in NUREG/CR-7267 NR NR NR NR
RSCS TSD 25-103 Revision 0 7
Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Values and Bases for RESRAD-Onsite Parameters for DCGL Calculations Industrial Use Scenario with Drinking Water Pathway Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersa Median/
Mean 1
2 3
4 Contaminated zone hydraulic conductivity (m/y)
P 2
D 2741 2017 Hydrogeologic Investigation Report NR NR NR NR Contaminated zone b parameter P
2 S
Bounded Log Normal n NUREG/CR-7267 distribution for site soil type - sand
- 0.0253 0.216 0.501 1.90 0.975 Humidity in air (g/m3)
P 3
D 6.6 Figure 1 in Regional and Site-Specific Absolute Humidity Data for Use in Tritium Dose Calculations (figure provide below)
NR NR NR NR Evapotranspiration coefficient P
2 D
S 6.9E-01 Uniform 75th percentile assigned to H-3 NUREG/CR-7267 assigned to all other ROCs 0.5 0.75 0.625 Average annual wind speed (m/s)
P 2
D 3.13 Internet search:
https://www.windfinder.c om/windstatistics/oyster_c reek_barnegat_bay NR NR NR NR Precipitation (m/y)
P 2
D 1.4 Annual Report on the Meteorological Program at Oyster Creek Generating Station - average annual precipitation for 2015 through 2020 NR NR NR NR Irrigation (m/y)
B 3
D 0.2 RESRAD default NR NR NR NR Irrigation mode B
3 D
Overhead Overhead irrigation is common practice for crops in U.S.
NR NR NR NR Runoff coefficient P
2 D
0.2 Value determined using methodology described in Data Collection Handbook and NUREG/CR-7267 NR NR NR NR Watershed area for nearby stream or pond (m2)
P 3
D 1.01E+08 NJ-GeoWeb (NJDEP BGIS)
NR NR NR NR Accuracy for water/soil computations 3
D 1.00E-03 RESRAD Default NR NR NR NR Saturated Zone Hydrological Data Density of saturated zone (g/cm3)
P 1
S Bounded Normal NUREG/CR-7267 Table C-1, distribution for site soil type - sand 1.5105 0.159 1.019 2.002 1.5105 Saturated zone total porosity P
1 S
Bounded Normal NUREG/CR-7267 distribution for site soil type - sand 0.43 0.06 0.2446 0.6154 0.43 Saturated zone effective porosity P
1 D
0.25 2017 Hydrogeologic Investigation Report NR NR NR NR Saturated zone field capacity P
3 D
0.18 Value based on site-specific soil type (sand); calculated using equation in NUREG/CR-7267 NR NR NR NR
RSCS TSD 25-103 Revision 0 8
Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Values and Bases for RESRAD-Onsite Parameters for DCGL Calculations Industrial Use Scenario with Drinking Water Pathway Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersa Median/
Mean 1
2 3
4 Saturated zone hydraulic conductivity (m/y)
P 1
D 2741 2017 Hydrogeologic Investigation Report NR NR NR NR Saturated zone hydraulic gradient P
2 S
Uniform 2017 Hydrogeologic Investigation Report (section 5.1.4) 0.01 0.04 0.025 Saturated zone b
parameter P
2 S
Bounded Log Normal n NUREG/CR-7267 distribution for site soil type - sand
- 0.0253 0.216 0.501 1.90 0.975 Water table drop rate (m/y)
P 3
D 1.00E-03 RESRAD Default NR NR NR NR Well pump intake depth (m
below water table)
P 2
D 10 RESRAD Default NR NR NR NR Model:
Nondispersion (ND) or Mass-Balance (MB)
P 3
D ND ND model recommended for contaminant areas
>1,000 m2 NR NR NR NR Well pumping rate (m3/y)
P 2
D 1.64 NUREG/CR-7267.
Unsaturated Zone Hydrological Data Number of unsaturated zone strata P
3 D
1 2017 Hydrogeologic Investigation Report (Figures 5.7 & 5.8)
NR NR NR NR Unsat.
zone 1,
thickness (m)
P 1
S Uniform Distribution developed from depth range for site groundwater, 5 ft - 20 ft (2017 Hydrogeologic Investigation Report (section 2.4.3) and minimum thickness of CZ (0.5 ft) 1.37 5.94 3.65 Unsat. zone 1, soil density (g/cm3)
P 2
S Bounded Normal NUREG/CR-7267 distribution for site soil type - sand 1.5105 0.159 1.019 2.002 1.5105 Unsat. zone 1, total porosity P
2 S
Bounded Normal NUREG/CR-7267 distribution for site soil type - sand 0.43 0.06 0.2446 0.6154 0.43 Unsat.
zone 1,
effective porosity P
2 D
0.25 2017 Hydrogeologic Investigation Report NR NR NR NR Unsat. zone 1, field capacity P
3 D
0.18 Value based on site-specific soil type (sand); calculated using equation in NUREG/CR-7267 NR NR NR NR Unsat.
zone 1,
hydraulic conductivity (m/y)
P 2
D 2741 2017 Hydrogeologic Investigation Report NR NR NR NR Unsat. zone 1, soil-specific b parameter P
2 S
Bounded Log Normal n NUREG/CR-7267 distribution for site soil type - sand
- 0.0253 0.216 0.501 1.90 0.975 Occupancy
RSCS TSD 25-103 Revision 0 9
Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Values and Bases for RESRAD-Onsite Parameters for DCGL Calculations Industrial Use Scenario with Drinking Water Pathway Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersa Median/
Mean 1
2 3
4 Inhalation rate (m3/y)
B 3
D S
9.9E+03 Triangular 75th percentile value assigned to Am-241, Cm-243, Cm-244, Fe-55, H-3, Pu-238 NUREG/CR-7267 assigned to all other ROCs 4380 8400 13000 8593 Mass loading for inhalation (g/m3)
P 2
D S
2.9E-05 Continuous linear 75th percentile value assigned to Am-241, Cm-243, Cm-244, Fe-55, Np-237, Pu-238, Pu-241 NUREG/CR-7267 assigned to all other ROCs 2.3E-5 Exposure duration B
3 D
30 RESRAD Default Indoor dust filtration factor P
2 S
Uniform NUREG/CR-7267 0.15 0.95 0.55 Shielding
- factor, external gamma P
2 D
S 4.0E-01 Bounded lognormal-n 75th percentile assigned to Cm-243, Co-60, Cs-137, Eu-152, Eu-154, Mn-54, Nb-94, Np-237, Sb-125, Sr-90 NUREG/CR-7267 assigned to all other ROCs
-1.3 0.59 0.044 1
0.2725 Fraction of time spent indoors B
3 D
0.03 Fraction of calendar year assuming 1h/work day for daily work breaks Fraction of time spent outdoors B
3 D
0.2 Fraction of calendar year assuming 7h/work day for outside tasks Shape factor
- flag, external gamma P
3 D
Circular RESRAD Default - Circular contaminated zone assumed Ingestion, Dietary
- Fruits, vegetables, grain consumption (kg/y)
B 2
D N/A Input not required - plant ingestion pathway inactive Leafy vegetable consumption (kg/y)
B 3
D N/A Input not required - plant ingestion pathway inactive NR NR NR NR Milk consumption (L/y)
B 2
D N/A Input not required - milk ingestion pathway inactive NR NR NR NR Meat and poultry consumption (kg/y)
B 3
D N/A Input not required - meat ingestion pathway inactive NR NR NR NR Fish consumption (kg/y)
B 3
D 20.6 NUREG/CR-5512, Vol. 3 NR NR NR NR Other seafood consumption (kg/y)
B 3
D 0.9 RESRAD Default NR NR NR NR Soil & dust ingestion rate (g/yr)
B 2
D S
2.4E+01 Triangular 75th percentile value assigned to Am-241, Cm-243, Cm-244, Fe-55, Ni-63, Np-237, Pu-238, Pu-239, Pu-240, Pu-241, Sr-90 NUREG/CR-7267 assigned to all other ROCs 0
18.3 36.5 18.3
RSCS TSD 25-103 Revision 0 10 Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Values and Bases for RESRAD-Onsite Parameters for DCGL Calculations Industrial Use Scenario with Drinking Water Pathway Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersa Median/
Mean 1
2 3
4 Drinking water intake (L/y)
B 2
D 478.5 NUREG/CR-5512 Contamination fraction of drinking water P
3 1.0 Assume DW from GW Contamination fraction of household water P
3 N/A Input not required - water pathway inactive Contamination fraction of livestock water P
3 N/A Input not required drinking water/ingestion pathways inactive Contamination fraction of irrigation water P
3 N/A Input not required - plant ingestion pathway inactive Contamination fraction of aquatic food P
2 D
S 6.1E-01 Triangular 75th percentile assigned to Tc-99 NUREG/CR-7267 assigned to all other ROCs 0
0.39 1
0.45 Contamination fraction of plant food P
3 N/A Input not required - plant ingestion pathway inactive Contamination fraction of meat P
3 N/A Input not required - meat ingestion pathway inactive Contamination fraction of milk P
3 N/A Input not required - milk ingestion pathway inactive Ingestion, Non-Dietary Livestock fodder intake for meat (kg/d)
M 3
N/A Input not required - meat ingestion pathway inactive Livestock fodder intake for milk (kg/d)
M 3
N/A Input not required - milk ingestion pathway inactive Livestock water intake for meat (L/d)
M 3
N/A Input not required - water ingestion pathway inactive Livestock water intake for milk (L/d)
M 3
N/A Input not required - milk ingestion pathway inactive Livestock soil intake (kg/d)
M 3
N/A Input not required - meat ingestion pathway inactive Mass loading for foliar deposition (g/m3)
P 3
N/A Input not required - plant ingestion pathway inactive Depth of soil mixing layer (m)
P 2
D 0.15 RESRAD Default Depth of roots (m)
P 1
N/A Input not required - plant ingestion pathway inactive Drinking water fraction from ground water P
3 D
1.0 All drinking water assumed from groundwater Household water fraction from ground water (if used)
P 3
N/A Input not required drinking water pathway inactive Livestock water fraction from ground water P
3 N/A Input not required drinking water/meat ingestion pathways inactive Irrigation fraction from ground water P
3 N/A Input not required drinking water pathway inactive
RSCS TSD 25-103 Revision 0 11 Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Values and Bases for RESRAD-Onsite Parameters for DCGL Calculations Industrial Use Scenario with Drinking Water Pathway Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersa Median/
Mean 1
2 3
4 Wet weight crop yield for Non-Leafy (kg/m2)
P 2
N/A Input not required - plant ingestion pathway inactive Wet weight crop yield for Leafy (kg/m2)
P 3
N/A Input not required - plant ingestion pathway inactive Wet weight crop yield for Fodder (kg/m2)
P 3
N/A Input not required - meat ingestion pathway inactive Growing Season for Non-Leafy (y)
P 3
N/A Input not required - plant ingestion pathway inactive Growing Season for Leafy (y)
P 3
N/A Input not required - plant ingestion pathway inactive Growing Season for Fodder (y)
P 3
N/A Input not required - meat ingestion pathway inactive Translocation Factor for Non-Leafy P
3 N/A Input not required - plant ingestion pathway inactive Translocation Factor for Leafy P
3 N/A Input not required - plant ingestion pathway inactive Translocation Factor for Fodder P
3 N/A Input not required - meat ingestion pathway inactive Weathering Removal Constant for Vegetation (1/y)
P 2
N/A Input not required - plant ingestion pathway inactive Wet Foliar Interception Fraction for Non-Leafy P
3 N/A Input not required - plant ingestion pathway inactive Wet Foliar Interception Fraction for Leafy P
2 N/A Input not required - plant ingestion pathway inactive Wet Foliar Interception Fraction for Fodder P
3 N/A Input not required - meat ingestion pathway inactive Dry Foliar Interception Fraction for Non-Leafy P
3 N/A Input not required - plant ingestion pathway inactive Dry Foliar Interception Fraction for Leafy P
3 N/A Input not required - plant ingestion pathway inactive Dry Foliar Interception Fraction for Fodder P
3 N/A Input not required - meat ingestion pathway inactive Storage times of contaminated foodstuffs (days)
- Fruits, non-leafy vegetables, and grain B
3 N/A Input not required - plant ingestion pathway inactive Leafy vegetables B
3 N/A Input not required - plant ingestion pathway inactive Milk B
3 N/A Input not required - milk ingestion pathway inactive Meat and poultry B
3 N/A Input not required - meat ingestion pathway inactive Fish B
3 D
7 RESRAD Default Crustacea and mollusks B
3 D
7 RESRAD Default Well water B
3 1.0 RESRAD default Surface water B
3 N/A Input not required drinking water pathway inactive
RSCS TSD 25-103 Revision 0 12 Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Values and Bases for RESRAD-Onsite Parameters for DCGL Calculations Industrial Use Scenario with Drinking Water Pathway Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersa Median/
Mean 1
2 3
4 Livestock fodder B
3 N/A Input not required - meat ingestion pathway inactive Special Radionuclides (C-14)
C-12 concentration in water (g/cm3)
P 3
D 2.00E-05 RESRAD Default C-12 concentration in contaminated soil (g/g)
P 3
D 3.00E-02 RESRAD Default Fraction of vegetation carbon from soil P
3 D
2.00E-02 RESRAD Default Fraction of vegetation carbon from air P
3 D
9.80E-01 RESRAD Default C-14 evasion layer thickness in soil (m)
P 2
D 0.3 RESRAD Default C-14 evasion flux rate from soil (1/s)
P 3
D 7.00E-07 RESRAD Default C-12 evasion flux rate from soil (1/s)
P 3
D 1.00E-10 RESRAD Default Fraction of grain in beef cattle feed B
3 D
0.8 RESRAD Default Fraction of grain in milk cow feed B
3 D
0.2 RESRAD Default Inhalation Dose Conversion Factors (mrem/pCi inhaled) from FGR11 (contained in RESRAD Dose Conversion Library)
Ingestion Dose Conversion Factors (mrem/pCi ingested) from FGR11 (contained in RESRAD Dose Conversion Library)
Plant Transfer Factors (pCi/g plant)/(pCi/g soil) Note: Plant ingestion pathway closed - input for plant transfer factors not required for Industrial Use dose calculations.
Meat Transfer Factors (pCi/kg)/(pCi/d) Note: Meat ingestion pathway closed - input for meat transfer factors not required for Industrial Use dose calculations.
Milk Transfer Factors (pCi/L)/(pCi/d) Note: Milk ingestion pathway closed - input for milk transfer factors not required for Industrial Use dose calculations.
Bioaccumulation Factors for Fish ((pCi/kg)/(pCi/L))
Ac-227 P
2 S
Lognormal-n NUREG/CR-7267 3.2 1.1 Am-241 P
2 S
Lognormal-n NUREG/CR-7267 5.5 1.1 Am-243 P
2 S
Lognormal-n NUREG/CR-7267 5.5 1.1 C-14 P
2 S
Lognormal-n NUREG/CR-7267 13.0 1.1 Cm-243 P
2 S
Lognormal-n NUREG/CR-7267 3.4 1.1 Cm-244 P
2 S
Lognormal-n NUREG/CR-7267 3.4 1.1 Co-60 P
2 S
Lognormal-n NUREG/CR-7267 4.3 0.9 7.4E+01 Cs-137 P
2 S
Lognormal-n NUREG/CR-7267 7.8 0.9 2.4E+03 Eu-152 P
2 S
Lognormal-n NUREG/CR-7267 4.9 1.6 1.3E+02 Eu-154 P
2 S
Lognormal-n NUREG/CR-7267 4.9 1.6 1.3E+02 Fe-55 P
2 S
Lognormal-n NUREG/CR-7267 5.1 1.9 1.6E+02 Gd-152 P
2 S
Lognormal-n NUREG/CR-7267 3.4 1.1 3.0E+01 H-3 P
2 S
Lognormal-n NUREG/CR-7267 0
0.1 1.0E+00 Mn-54 P
2 S
Lognormal-n NUREG/CR-7267 5.5 1.9 2.4E+02 Nb-94 P
2 S
Lognormal-n NUREG/CR-7267 5.7 1.1 3.0E+02
RSCS TSD 25-103 Revision 0 13 Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Values and Bases for RESRAD-Onsite Parameters for DCGL Calculations Industrial Use Scenario with Drinking Water Pathway Parameter (unit)
Type Priority Treatment Value/Distribution Basis Distribution's Statistical Parametersa Median/
Mean 1
2 3
4 Ni-63 P
2 S
Lognormal-n NUREG/CR-7267 3.0 0.6 2.0E+01 Np-237 P
2 S
Lognormal-n NUREG/CR-7267 3.0 1.1 2.0E+01 Pa-231 P
2 S
Lognormal-n NUREG/CR-7267 2.3 1.1 1.0E+01 Pb-210 P
2 S
Lognormal-n NUREG/CR-7267 3.2 1.1 2.5E+02 Po-210 P
2 S
Lognormal-n NUREG/CR-7267 3.6 1.5 3.7E+01 Pu-238 P
2 S
Lognormal-n NUREG/CR-7267 10.0 1.0 2.2E+04 Pu-239 P
2 S
Lognormal-n NUREG/CR-7267 10.0 1.0 2.2E+04 Pu-240 P
2 S
Lognormal-n NUREG/CR-7267 10.0 1.0 2.2E+04 Pu-241 P
2 S
Lognormal-n NUREG/CR-7267 10.0 1.0 2.2E+04 Ra-226 P
2 S
Lognormal-n NUREG/CR-7267 1.4 1.9 4.1E+00 Ra-228 P
2 S
Lognormal-n NUREG/CR-7267 1.4 1.9 4.1E+00 Sb-125 P
2 S
Lognormal-n NUREG/CR-7267 3.6 1.5 3.7E+01 Sr-90 P
2 S
Lognormal-n NUREG/CR-7267 1.1 1.4 3.0E+00 Tc-99 P
2 D
4.2E+01 75th percentile Te-125m P
2 S
Lognormal-n NUREG/CR-7267 5.0 0.4 1.5E+02 Th-228 P
2 S
Lognormal-n NUREG/CR-7267 4.6 1.1 9.9E+01 Th-229 P
2 S
Lognormal-n NUREG/CR-7267 4.6 1.1 9.9E+01 Th-230 P
2 S
Lognormal-n NUREG/CR-7267 4.6 1.1 9.9E+01 Th-232 P
2 S
Lognormal-n NUREG/CR-7267 4.6 1.1 9.9E+01 U-233 P
2 S
Lognormal-n NUREG/CR-7267 0.0 2.5 1.0E+00 U-234 P
2 S
Lognormal-n NUREG/CR-7267 0.0 2.5 1.0E+00 U-235 P
2 S
Lognormal-n NUREG/CR-7267 0.0 2.5 1.0E+00 U-236 P
2 S
Lognormal-n NUREG/CR-7267 0.0 2.5 1.0E+00 Bioaccumulation Factors for Crustacea/ Mollusks ((pCi/kg)/(pCi/L)) RESRAD default value for each radionuclide applied Graphics Parameters Number of points 32 RESRAD Default Spacing log RESRAD Default Time integration parameters Maximum number of points for dose 17 RESRAD Default a Distributions Statistical Parameters:
Lognormal-n: 1= mean, 2 = standard deviation Bounded lognormal-n: 1= mean, 2 = standard deviation, 3 = minimum, 4 = maximum Truncated lognormal-n: 1= mean, 2 = standard deviation, 3 = lower quantile, 4 = upper quantile Bounded normal: 1 = mean, 2 = standard deviation, 3 = minimum, 4 = maximum Triangular: 1 = minimum, 2 = mode, 3 = maximum Uniform: 1 = minimum, 2 = maximum
RSCS TSD 25-103 Revision 0 14 Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil 3 Results The peak of the mean (POM) doses from RESRAD-Onsite probabilistic code executions are used to develop DGL values that correspond to the NRC unrestricted release criterion (25 mrem/y) as follows:
DCGL value, pCi/g = (25 mrem/y)/(POM dose, mrem/y per 1pCi/g)
Table 3 provides the RESRAD-Onsite results and DCGL values with an open DW pathway by ROC.
Table 3. DCGL Values with Open DW Pathway ROC POM Dose (mrem/y)
DCGL (pCi/g)
ROC POM Dose (mrem/y)
DCGL (pCi/g)
Am-241 3.42E-02 7.30E+02 Nb-94 2.01E+00 1.25E+01 C-14 1.23E-02 2.03E+03 Ni-63 4.56E-06 5.48E+06 Cm-243 1.38E-01 1.81E+02 Np-237 6.08E+00 4.11E+00 Cm-244 1.37E-02 1.82E+03 Pu-238 2.20E-02 1.14E+03 Co-60 3.15E+00 7.94E+00 Pu-239 1.40E-01 1.79E+02 Cs-137 6.99E-01 3.58E+01 Pu-240 1.16E-01 2.16E+02 Eu-152 1.42E+00 1.76E+01 Pu-241 1.00E-03 2.49E+04 Eu-154 1.53E+00 1.63E+01 Sb-125 4.50E-01 5.56E+01 Fe-55 2.98E-06 8.39E+06 Sr-90 1.13E-02 2.22E+03 H-3 7.94E-03 3.15E+03 Tc-99 3.98E-01 6.29E+01 Mn-54 7.34E-01 3.41E+01 An open DW pathway lowers the DCGL values for several ROCs as shown in Table 4.
Table 4. Surface Soil DCGL Values Without and With an Open DW Pathway ROC IU DCGL Value (pCi/g)
Without DW With DW Am-241 7.31E+02 7.30E+02 C-14 2.07E+03 2.03E+03 Cm-243 1.81E+02 1.81E+02 Cm-244 1.82E+03 1.82E+03 Co-60 7.94E+00 7.94E+00 Cs-137 3.58E+01 3.58E+01 Eu-152 1.76E+01 1.76E+01 Eu-154 1.63E+01 1.63E+01 Fe-55 8.39E+06 8.39E+06 H-3 5.02E+04 3.15E+03 Mn-54 3.41E+01 3.41E+01 Nb-94 1.25E+01 1.25E+01 Ni-63 7.74E+06 5.48E+06
RSCS TSD 25-103 Revision 0 15 Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil ROC IU DCGL Value (pCi/g)
Without DW With DW Np-237 5.75E+01 4.11E+00 Pu-238 1.14E+03 1.14E+03 Pu-239 3.06E+02 1.79E+02 Pu-240 2.92E+02 2.16E+02 Pu-241 2.50E+04 2.49E+04 Sb-125 5.56E+01 5.56E+01 Sr-90 4.24E+03 2.22E+03 Tc-99 1.37E+04 6.29E+01 4 References
- 1. ENG-OCS-008, Derived Concentration Guideline Levels Values for Soil - Industrial Use Scenario, July 26, 2023
- 2. ANL/EVS/TM-18/1, Users Guide for RESRAD-Onsite Code, Version 7.2, March 2018
- 3. TSD 25-032, Radionuclides of Concern in Support of the Oyster Creek Station License Termination Plan, Revision 0
RSCS TSD 25-103 Revision 0 16 Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Pages from the RESRAD-Onsite reports showing the POM dose values by radionuclide:
Am-241 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 17:06 Page 20 Probabilistic results summary : OCNGS Industrial Use_DW_Soil_DCGL_Am241 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\AM241\\OC_IU_DW_SOIL_AM241.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 0.000E+00 3.423E-02 C-14 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 11:25 Page 20 Probabilistic results summary : OCNGS Industrial Use_DW_Soil_DCGL_C14 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\C14\\OC_IU_DW_SOIL_C-14.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 4.125E+01 1.231E-02 CM-243 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 20:03 Page 20 Probabilistic results summary : OCNGS Industrial Use_DW_Soil_Cm243 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\CM243\\OC_IU_DW_SOIL_CM243.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 0.000E+00 1.379E-01 Cm-244 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 21:20 Page 20 Probabilistic results summary : OCNGS Industrial Use_DW_Soil_Cm244 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\CM244\\OC_IU_DW_SOIL_CM244.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 0.000E+00 1.371E-02 Co-60 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 12:38 Page 20 Probabilistic results summary : OC_IU_DW_Soil_Co60 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\CO60\\OC_IU_DW_SOIL_CO60.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 0.000E+00 3.148E+00 Cs-137 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 13:09 Page 20 Probabilistic results summary : OCNGS Industrial Use_DW_Soil_Cs137 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\CS137\\OC_IU_DW_SOIL_CS137.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 0.000E+00 6.992E-01 Eu-152 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 13:35 Page 20 Probabilistic results summary : OCNGS Industrial Use_DW_Soil_Eu152 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\EU152\\OC_IU_DW_SOIL_EU152.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 0.000E+00 1.417E+00
RSCS TSD 25-103 Revision 0 17 Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Eu-154 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 14:12 Page 20 Probabilistic results summary : OCNGS Industrial Use_DW_Soil_Eu154 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\EU154\\OC_IU_DW_SOIL_EU154.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 0.000E+00 1.531E+00 Fe-55 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 14:30 Page 20 Probabilistic results summary : OCNGS Industrial Use_DW_Soil_Fe55 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\FE55\\OC_IU_DW_SOIL_FE55.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 0.000E+00 2.981E-06 H-3 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 14:48 Page 20 Probabilistic results summary : OCNGS Industrial Use_DW_Soil_H3 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\H3\\OC_IU_DW_SOIL_H3.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 2.219E+00 7.941E-03 Mn-54 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 15:16 Page 20 Probabilistic results summary : OCNGS Industrial Use_DW_Soil_Mn54 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\MN54\\OC_IU_DW_SOIL_MN54.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 0.000E+00 7.335E-01 Nb-94 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 15:38 Page 20 Probabilistic results summary : OC_IU_DW_Soil_Nb94 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\NB94\\OC_IU_DW_SOIL_NB94.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 0.000E+00 2.008E+00 Ni-63 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 15:57 Page 20 Probabilistic results summary : OC_IU_DW_Soil_Ni63 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\NI63\\OC_IU_DW_SOIL_NI63.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 9.152E+01 4.560E-06 Np-237 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 17:32 Page 20 Probabilistic results summary : OC_IU_DW_Soil_Np237 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\NP237\\OC_IU_DW_SOIL_NP237.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 2.031E+02 6.082E+00 Pu-238 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 18:56 Page 20 Probabilistic results summary : OC_IU_DW_Soil_Pu238 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\PU238\\OC_IU_DW_SOIL_PU238.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose
RSCS TSD 25-103 Revision 0 18 Industrial Use Scenario with Open Drinking Water Pathway:
An Assessment of Impact on DCGL Values for Surface Soil Years mrem/yr 1 0.000E+00 2.202E-02 Pu-239 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 19:18 Page 20 Probabilistic results summary : OC_IU_DW_Soil_Pu239 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\PU239\\OC_IU_DW_SOIL_PU239.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 1.000E+03 1.398E-01 Pu-240 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/26/2025 13:52 Page 20 Probabilistic results summary : OC_IU_DW_Soil_Pu240 with DW File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\PU240 IU SOIL W DW\\OC_IU_DW_SOIL_PU240.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 1.000E+03 1.156E-01 Pu-241 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 17:57 Page 20 Probabilistic results summary : OC_IU_DW_Soil_Pu241 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\PU241\\OC_IU_DW_SOIL_PU241.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 5.380E+01 1.003E-03 Sb-125 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 16:17 Page 20 Probabilistic results summary : OC_IU_DW_Soil_Sb-125 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\SB125\\OC_IU_DW_SOIL_SB125.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 0.000E+00 4.500E-01 Sr-90 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 16:33 Page 20 Probabilistic results summary : OC_IU_DW_Soil_Sr-90 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\SR90\\OC_IU_DW_SOIL_SR90.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 4.125E+01 1.125E-02 Tc-99 1RESRAD-ONSITE, Version 7.2 T<< Limit = 30 days 02/19/2025 16:54 Page 20 Probabilistic results summary : OC_IU_DW_Soil_Tc-99 File : C:\\RESRAD_FAMILY\\ONSITE\\7.2\\USERFILES\\RESRAD OC FILES\\SOIL\\INDUSTRIAL USE\\IU WITH DW PATHWAY\\TC99\\OC_IU_DW_SOIL_TC99.RAD Peak of the mean dose (averaged over observations) at graphical times Repetition Time of peak mean dose Peak mean dose Years mrem/yr 1 1.701E+00 3.977E-01