I i
- 4 S i,XL,..SiTAl,,
fil.E COEY-
/
4
\\
l OCT 2 61967 Docke.t No. 50-275 Pacific Cas & Elet.tric Company 245 Market Street San Francisco, California 94106 Attention:
Mr. Richard H. Peterson Senior VI:e Presideot &
General Counsel Gentlemen:
This refers to your application for a construction permit and : facility license for a nucicar power plant to be located at *.he Diablo Canyon site. We have reviewed Supplements 1, 2 and 3 to your application which were submitted in response to our questions for additional infor-mation.
Further discussions on the proposed plant design vero held with representatives of your company, the Westinghouse Electric Company, the Division of Reactor Licensing, and the Advisory Commictee on Reactor Safeguards on October 3, 4, and 5, 1967.
As we have discussed with you, we densider the following major safety review areas as not completely resolved in terms of satisfactory documentation of the plant design and proposed operation:
(a) seismic design in terms of criteria for all Class I systens and components considering load combinations and allowable stresses or deformation.
(b) the instrumentation and control system in regard to the proposed increased core average power density including an evaluation for additional in-core monitoring capability in conjunction with the part-length control rods.
(c) a safety evaluation to support the adequacy of the proposed emergency core cooling system including consideration of the existence o? single pipe lines connecting various subsystems.
8808250331 000721
-li
.6 Pacific Cas &
2-Electric Company OCT % 61967 (d) a safety evaluation associated with the effects of seismic and blowdown forces acting on the reactor core to af fect reactivity.
He understand that you intend to submit additional information in November 1967 in response to our letter, dated August 31, 1967, This information relates to the research and development programs appropriate for the Diablo Canyon plant and the appropriate matters identified by an asterisk in the June 15, 1967 ACRS report on the Vermont Yankee Nuclear Power Station.
We also believe that supplemental inforuation related to a prelim-~
inary design and safety evaluation of the instrumentation and control system is required. The description and evaluation of the protection systems, submitted in the second and third supplements, which actuate reactor trip, containment isolation, emergency core cooling system, and other engineerinE safety features do not provide a sufficient technical basis upon which to make a safety evaluation.
An ovalua-tion of the protection systems based on this information would be little more than an evaluation of design criteria. We need the specific information requested in our questions, including a prelim-inary design, so we can evaluate the approach to implementation of the criteria.
In addition to this information, based on discussions at the recent meetings and review of the information available, we have found that further information is required to enable us to continue and complete our review. In this regard, we require the specific information detailed in the enclosed questions.
Distribution:
AEC Doc. Rm.
To complete our review and to prepare a report to the ACRS, we will SAN Doc. Rm.
require early submittal of complete and satisfactory replies to this LA Doc. Rm.
We shall be available to discuss and cisrify any of the Forms 1 request.
Suppl.
aspects of the foregoing with you.
REG Rdg.
Sincerely youro, DRL Rdg.
RPB-2 Rdg.
Orig: RLTedesco
/
/J P. A. Morris M. M. Mann Peter A. Morris, Director R. S. Boyd Division of Reactor Licensing L. Kornb'11th (2)
ORNL J. R. Buchanan, Enclosure S. Levine Request for Additional Information H. Steele srr ATTArnrn surrT vnn nTurn envenonrecre o.
c.,. ; _ 3. _ m.
u.
.....yest,inghop(sp. Atpm.ic_,P,o,,ger Division.
....DRL :P
..DRL.:RT...
. _ dry....
omct >
P. O. Box 355 RLTedes y>/dj p4]
... ittsburg).q,,Pennsylvan,ia,,15230
.RSBoyd..L
..Stev.ine.......rAv.or.r.is.
P sum m t>
.......__/2a6/6 7
..I....................................
10/26/674 10/
/. 67 10 out w rpyatn.
a Wrm AEC.389 (Rev.S.us y,
,g g g s
-n
i i
REQUEST FOR ADDITIONAL INFORMATION PACIFIC CAS & ELECTRIC COMPANY DOCKET NO. 50-27 5 We understand that modifications are to. be made to the reactor protection
)
1.
system to use a dif ferential signal derived from the upper and lowcr half In sections of the long ion chambers to reset the level trip setting.
this regard, please describe the proposed changes including a safety eval-untion and a preliminary design covering the significant aspects of the modifications.
Describe the results of a safety evaluation treating the effects of forces 2.
on the reactor core considering the movement of fuel rods and fuel pellets The evaluation should be broad in scope to include from damaged fuel rods.
the superposition of seismic loads and loss of coolant accident loads as Areas of well as each of these loading conditions acting independently.
interest include the reactivity effects due to fuel movements and the ability of the core to remain intact and coolable under these conditions.
j Our preliminary review of the piping systems proposed for the emergency 3.
core cooling system indicates the existence of single pipe lines connecting the various subsystems from the refueling water storage tank to the Auxil-isry 3uilding and then through the containment to the reactor primary systso Such an arrangement suggests with a return via the recirculation system.
a potential loss of core cooling capability in an unlikely event of any failure leading to excessive leakage from the proposed single line system.
On this basis, please describe the protection provided in terne of leakage detection and isolation capability that will be provided to detect such failures to assure core cooling.
Our Design Criteria, which were published for comment on July 11, 1967, 4.
includes a criterion (number 44) for providing at least two independent Our review of the proposed emergency core cooling core cooling sys tems.
indicates the existence of single subsystems (even though redundancy has '
been provided in certain of the active components as well as for tha accumulators) to provide core cooling capability over the entire pri-On this basis, please describe in mary system piping break spectrum.
detail the results of your safety evaluation of the proposed core cooling system in consideration of meeting the objectives stated in Criterion 44, Provide a detailed sketch showing the piping,onfiguration from the c
5.
containment sump to the RNR system as indicated in Figure VI D 3 of Supplement 3.
Emphasis should be given to the guard pipe design leading from the contaionent sump to Auxiliary Building.
i m >
s-
,-e
,v.-<
,-v vw.
p-,v,-
--y v
,g
-,g-
,w-ww
,wv pr,-
1 The proposed diesel fuel storage capacity as stated on page 135 of Supplement 6.
Describe the evaluation conducted that leads to the conclusion 3 is 5 days.
that a 5-day supply is adequate.
Include a discussion related to obtaining additional fuel from nearby sources.
Describe the results of your safety evaluation of the containment penetra-7.
tion design for the main s team lines.
Indicate the design criteria for these penetrations which should include the local effects of jet impinge-ment and thrust loads for assurance of maintaining containment integrity.
Describe the results of a safety evaluation regarding the safety aspects 8.
of a seismic scram trip for the proposed facility.
Describe the design provisions including e safety evaluation regarding the 9.
capability of control rod cluster insertion to make the reactor subcritical considering the combined loading effects resulting from earthquake and blow-Include a discussion concerning provisions in the design of down forces.
the reactor internals to assure that the control rods would be inserted into the core by gravitational forces under combined effects of seismic and accident forces.
For the piping, vessels, supports, and reactor vessel internals, separately, 10.
provide the following criteria type information:
(a) the loading combinations to be employed in the designs and the reasoning for selection of the loading combinations (b) the stress or deformation limits for each case (a)
(c) the margin of ssfety between (b) and the expected collapse or failure condition.
For particular cases where calculations of maximum limits of deformation 11.
or stress (at which inability to function occurs) have been made, please supply such dets. Also in such cases supply the maximum design limit value, and the expected deformation or stress where this has been calcu-In all such cases the applicable loading combination should be lated.
identified, and any amplifying discussion of the margin of safety presented.
In cases where only stress intensity criteria are to be employed, as out-12.
lined in WCAP-5890-1, provide a realistic estimate of the strain, based on appropriate material properties at the applicable temperature, in order that an estimate of the margin of safety can be made.
Especially for those cases which fall outside the code-based "boxes" and in the region between the boxes and the limit curves it is imperative that the margin of safety
1 l
9 1
Confirmatory test data should also be supplied, if available, be identified.
With regard to WCAP-5890-1, provide addi-with interpretative discussion.
tional discussion regarding the applicability of the derivations in the report to the strain hardening domain.
In connection with the above, provide information that will permit eval-uation of the ef fect of welds, irradiation, corrosion, material imperfections (flaws), etc., in the design approach.
To the extent available, supply criteria or specific information on the 13.
interaction forces, deformation and stresses connected with the relative motions between the reactor vessel, steam generators or other large Indicate how these relative motions will be controlled by components.
snubbers or other means, and what reaction forces (and corresponding stresses) will be transmitted to the pipes.
The containment structure will be founded on bedrock and surrounded by 14.
Describe how the forces arising from any some 30 feet of overburden.
soil-structure interaction arising from normal and seismic loading will be evaluated and handled in the design.
Provide the actual and the simplified stress-strain curves for:
15.
The two materials used in recent limit analysis testa (a) per formed by Wes tinghouse.
The piping, vessel, and internals materials for which you (b) intend to use the limit analysis method outlined in WCAP-5890-1.
For materials listed in (b) above, provide also, if available, the stress-strain curves obtained from tests using larger test specimens than those I
Discuss the thickness effect on the shape of the l
specified by the ASME.
stress-s train curve, and es timate the maximum material thickness for which the limit curves given in the WCAP-5890-1 are applicable.
i l
l l