ML20138F303
| ML20138F303 | |
| Person / Time | |
|---|---|
| Site: | Saint Lucie |
| Issue date: | 09/05/1996 |
| From: | Essig T NRC (Affiliation Not Assigned) |
| To: | Hebdon F NRC (Affiliation Not Assigned) |
| Shared Package | |
| ML20136C539 | List:
|
| References | |
| FOIA-96-485 NUDOCS 9609110078 | |
| Download: ML20138F303 (3) | |
Text
. _. _ _ _ _ _._.. _._. _ _. _..._
Septembar 5, 1996 f
MEMORAIERM T0:
Frederick J. Hebdon, Director Project Ofrectorate II-3 i
Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation FROM:
Thomas H. Essig, Chief original signed by:
Emergency Preparedness and Environmental r
Health Physics Section Emergency Preparedness and Radiation Protection Branch i
Division of Reactor Project Management Office of Nuclear Reactor Regulation e
SUBJECT:
SAFETY EVALUATION 0F FLORIDh POWER Ale LIGHT COMPANY (FPL)
PROPOSED EMERGENCY ACTION LEVEL REVISION FOR THE ST. LUCIE I
PLANT l
Sy letter dated July 25, 1996, FPL proposed a revision to Table 3-1 of their Emergency Plan. They requested approval, prior to implementation, of a change to an Emergency Action Level (EAL) regarding reactor coolant system (RCS) l 1eakage. The proposed change revises the declaration threshold for the EAL of an Unusual Event involving RCS leakage.
The Emergency Preparedness and Environmental Health Physics Section has completed its review and found that the proposed EAL asets the requirements of 10 CFR 50.47(b)(4) and Appendix E to 10 CFR 50 for emergency classification and action level schemes. Based upon our evaluation, we recommend that the licensee be authorized to implement this change to their plan.
Docket Nos. 50-335 and 389
Attachment:
Safety evaluation for proposed emergency action level CONTACT: Lawrence K. Cohen, NRR/0 RPM /PER8 415-2923 DISTRIBUT ON Decket F1 e BKGrimes TTMartin PERB READING FILE KP8arr, RII CMiller RWeins, PM D0CIMENT NAME: G:STLUCIE.EAL l
To receive a copy of this document, indicate in the box:
"C" - Copy without attachment / enclosure "E" - Copy with attachment / enclosure
- N" = No copy 0FFICE PERS:NRR Ii PERS:NR44 J E.
I I
I NAME LKCohen A TEssig ' R t DATE 9/ 4 /96 9/ 6 /96 OFFICIdL RECORD COPY 3q g
3g, ih
(%o9ilont DFW
~
NRC FR.E CENTER COPY
,g
Septcaber 5, 1996
'I MEMORAELM 70:
Frederick J. Hebdon, Director
/.
Project Directorate II-3 Division of Reactor Projects - I/I!
Office of Nuclear Reactor Regulation FReM:
Thomas H. Essig, Chief original si Emergency Preparedness and EnvironmentaTed by:
4 Health Physics Section i
Emergency Preparedness and Radiation Protection Branch l
Division of Reactor Project Management Offlce of Nuclear Reactor Regulation
SUBJECT:
SAFETY EVALUATION 0F FLORIDA POWER A m LIGHT COMPANY (FPL)
PROPOSED EMERGENCY ACTION LEVEL REVISION FOR THE ST. LUCIE 1
PLANT 1
i By letter dated July 25, 1996 FPL proposed a revision to Table 3-1 of their Emergency Plan. They requested approval, prior to implementation, of a change 3
to an Emergency Action Level (EAL) regarding reactor coolant system (RCS) leakage. "he proposed change revises the declaration threshold for the EAL of an Unusual Event involving RCS leakage.
The Emergency Preparedness and Environmental Health Physics Section has completed its review and found that the proposed EAL meets the requirements of 10 CFR 50.47(b)(4) and Appendix E to 10 CFR 50 for emergency classification and action level schemes. Based upon our evaluation, we recommend that the licensee be authorized to implement this change to their plan.
Docket Nos. 50 *J5 and 389
Attachment:
Safety evaluation for proposed emergency action level CONTACT: Lawrence K. cohen, NRR/DRPN/FERS 415-2923 DISTRIBUTION Docket File BKGrimes 1TNartin PER8 READING FILE KP8arr, RII CMiller RWeins, PM 00CLMENT NAME: G:STLUCIE.EAL To receive a copy of this document, indicate in the box:
'C' = copy without attachment / enclosure "E" = Copy with attachment / enclosure
'N' = No copy 0FFICE PER8:NRR Id PERS: NRM JE l
l l
l' NAME LKCohen A TEssig % t i
DATE 9/ 4 /96 9/ 6 /96 l'
0FFICIA RECORD COPY 2
w,---_
""~~,
le p%,k j
f UNITO STATES r
y, -
NUCLEAR REGULATORY COMMISSION e,
WASNINGTON. D.C. seneHeet s
\\,,,,,
September 5, 1996 j.
MEMORAfGM T0:
Frederick J. Hebdon, Of rector Project Directorate 11-3 Division of Reactor Projects - I/II office of Nuclear Reactor Regulation t
FROM:
Thomas H. Essig, Chief p
gEmergencyPreparednessandEnvironmental Health Physics Section Emergency Preparedness and Radiation i
Protection Bran:h Division of Reactor Project Management Office of Nuclear Reactor Regulation
SUBJECT:
SAFETY EVALUATION OF FLORIDA POWER A W LIGHT COMPANY (FPL PROPOSED EMERGENCY ACTION LEVEL REVISION FOR THE ST. LUCIE PLANT By letter dated July 25, 1996 FPL proposed a revision to Table 3-1 of their Emergency Plan. They requested approval, prior to implementation, of a change to an Emergency Action Level (EAL) regarding reactor coolant system (RCS) leakage. The proposed change revises the declaration threshold for the EAL of an Unusual Event involving RCS leakage.
The Emergency Preparedness and Environmental Health Physics Section has completed its review and found that the proposed EAL meets the requirements of 10 CFR 50.47(b)(4) and Ap and action level schemes.pendix E to 10 CFR 50 for emergency classification Based upon our evaluation, we recommend that the Ilconsee be authorized to laplement this change to their plan.
Docket Nos. 50-335 and 389
Attachment:
Safety evaluation for proposed emergency action level CONTACT: Lawrence K. cohen, NRR/DRPM/PER8 415-2923
. -.