ML20138E629

From kanterella
Jump to navigation Jump to search
Forwards INEL-94/0147, TER on Second 10-Yr Interval ISI Program Plan:Fpl,St Lucie Nuclear Plant,Unit 2
ML20138E629
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 03/30/1995
From: Beth Brown
IDAHO NATIONAL ENGINEERING & ENVIRONMENTAL LABORATORY
To: Mclellan T
NRC (Affiliation Not Assigned), NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20136C539 List: ... further results
References
CON-FIN-L-2556, FOIA-96-485 BWB-14-95, NUDOCS 9504040251
Download: ML20138E629 (1)


Text

.

i%.O..$ /

W I. N E k :*

sense N.;'w.etto,o, es,eiesmewy j

s i

March 30, 1995 Mr. Thomas K. McLellan, Project Officer j

c/o Document Control Desk

}

Civil Engineering & Geosciences Branch Division of Engineering 4

U.S. Nuclear Regulatory Commission -

Washington, DC 20555 TRANSMITTAL OF TECHNICAL EVALUATION REPORT INEL-94/0147, ON THE SECOND 10-YEAR INTERVAL INSERVICE INSPECTION PROGRAM PLAN FOR ST. LUCIE NUCLEAR PLANT, UNIT 2 j

- BWB-14-95

Reference:

NRC Form 189, " Technical Assistance in Support of the NRC l

Inservice Inspection Program" (FIN-L2556, Task Order 20, NRC TAC No. M87208)

Dear Mr. McLellan:

i The subject report documents our review of the St. Lucie Nuclear Plant, Unit 2,.Second 10-Year Interval Inservice Inspection Program Plan, Revision 0, as submitted by Florida Power and Light Company, August 4, 1993. This report also includes evaluation of the requests for relief from the American Society of Mechanical Engineers (ASME) Boller and Pressure Vessel Code Section XI-j requirements that the licensee has determined to be impractical, i

This report completes the work under Task Assignment 20 of NRC FIN-L2556 for NRC TAC No. M87208.

i Sincerely.

C B. W. Brown, INEL Principal Investigater NDE Engineering Analysis and Applications BWB

Enclosure:

As Stated j

cc:

S. F. Armour, DOE-ID, MS 1219 I

G. Bagcht, NRR, MS 7H15 (w/o Enc 1)

D. Terao, NRR, MS 7H15 (w/o Encl)

'40 4

O40115 4Locleeed h

I

}lJ) 9 Idaho Technologies Company P. O. Box 1625 Idaho falls, ID 8341S

8. ".6.0 4' O yD 2s22M I

i