Value/Impact Assessment for Reg Guide 1.28,Revision 2:QA Program Requirements,Design & Const
ML19212A216
Person / Time
Site: Trojan File:Portland General Electric icon.png
Issue date: 07/09/1979
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML19207B153 List:
References
REGGD-01.028, REGGD-1.028, NUDOCS 7908230504
Download: ML19212A216 (3)


Text

.

~

VALUE/ IMPACT ASSESSMENT FOR REGULATORY GUIDE 1.28, REVISION 2, " QUALITY ASSURANCE PROGRAM REQUIREMENTS (DESIGN AND CONSTRUCTICN)"

The final value/ impact assessment presented with the Background Information memorandum (G. A. Arlotto to R. 8. Minogue dated February 10, 1978, copy attached), Section C; Value/ Impact of the Proposed Action, is valid for the guide at this stage of development.

Public Comments resulted in only two changes other than editorial corrections.

The value/ impact of these changes is discussed below.

Value/Incact of Cha ges to Reculatory Position C.2.b and e Regulatory Position C.2 jrovides guidance on the guidelines of the endorsed standard which shou ~1 be treated as requirements by applicants who commit to the guide.

Pu lic comments indicated that the sections

~~

relating to when audits should be conducted were subjective and unenforce-abic. They also commented that requir.ing audits as specified would 'ead to conducting an audit to verify corrective action when other methods may be more acceptable. We agree that this may be unnecessary and, therefore, Regulatory Positions C.2.b and e wers deleted and a new section C.3 was added. This section specifies that the recommendations of the indicated se'ctions and the subject of audit scheduling is addressed in more detail in a separate regulatory guide.

The value of this change is to delete inadequate guidance from the regulatory position.

Scheduling of audits is properly addressed

' WUSSO e

1 g g g '2 3 09[

b

D

~

ave in WASH 1283, Revision 1, Guidance on Quality Assurance Requirements During Design and Procurement Phase of Nuclear Power Plants and WASH 1309, Guidance on Quality Assurance Requirements During the Construction Phase of Nuclear Power Plants. These documents contain Rev. 3, Draft 4 of a proposed standard N45.2.12, " Requirements ior Auditing of QL.ality Assurance Programs for Nuclear Power Plants." The approved standard, ANSI /ASME N45.2.12-1977, is the subject of a regulatory guide currentiy being prepared by the staff.

There is no impact on the staff.

As indicated, audit scheduling is addressed in other NRC documents in more detail.

No guidance will be lost due to the subject change.

The value of the change to industry is to eliminate subjective and potentially confusing guidance that could Saad to an unnecessary pro-liferation of audits. There is no impact,

industry as guidance is available in other documents.

Value/'moact of the Chance to Regulatorv Position C.2.d.

The subject section recommended preparction of an audit plan for each audit.

Public comments indicated that this may be unnecessary in some cases. The value of deleting this section is that an audit plan is not required for all audits, and the time required to review audit plans for a41 audits may be better used in other areas.

The impact on the staff is negligible.

The first paragraph of Section 19 of the standard requires that audits be performed in accordance with written procedures or checklists.

2 (642.93

rihether or not this documentation takes the form of an audit plan is not essential.

The value to industry is to remove the requirement for an audit P!:..

for each audit. There is no impact on industry.

9 3

-cen300

.