Other: ML043230163, ML043500645, ML043510279, ML043650296, ML050050111, ML050050112, ML050050116, ML050050466, ML050050470, ML050060022, ML050060025, ML050060041, ML050060054, ML050060074, ML050060110, ML050060114, ML050060252, ML050060256, ML050060384, ML050060387, ML050120255, ML050120303, ML050140232, ML050140236, ML050140245, ML050140247, ML050140253, ML050140298
|
MONTHYEARML0500600411995-12-26026 December 1995 H-1-BB-MEE-1050 Hope Creek Recirculation System Large Bore Pipe Cracking Resolution, 12/26/1995 Project stage: Other ML0501402362002-07-12012 July 2002 Reactor Coolant Pump Shaft Cracking, July 12, 2002 Project stage: Other ML0500600252003-04-15015 April 2003 CR 70029861 Hope Creek B Recirculation Pump Excessive Seal Leakage Condition Report, 03/01/2003 Project stage: Other ML0501402982003-05-0707 May 2003 Drawing 1 of 2, M-43-1 P&Id, Reactor Recirculation System Project stage: Other ML0501402532004-04-29029 April 2004 HC-04Q-301 Hope Creek Extended Power Uprate Piping Vibration Monitoring, 4/29/2004 Project stage: Other ML0500603842004-09-0707 September 2004 C-0031 Piping Code Compliance, 9/7/2004 Project stage: Other ML0500600542004-10-19019 October 2004 Design Change Package 80062466 Revision 1 Extended Power Uprate Piping Vibration Monitoring Installation Package, 10/19/2004 Project stage: Other ML0501402452004-10-26026 October 2004 Flowserve RAL-7482 Rev 0 Design Modification Report Assy 93-15122, 10/26/2004 Project stage: Other ML0501402472004-10-26026 October 2004 Flowserve RAL-7483 Rev 0 Design Modification Report Assy 93-14347, 10/26/2004 Project stage: Other ML0500603872004-10-29029 October 2004 H1BC-1-BC-V183 (CR 20208920) Handwheel Operator Spins Freely, 11/08/2004 Project stage: Other ML0500501122004-10-30030 October 2004 HC.OP-SO.BB-0002(Q) Rev 50A Reactor Recirculation System Operating Procedures, 10/30/2004 Project stage: Other ML0500501162004-10-30030 October 2004 HC-OP-AR.ZZ-0008(Q), Rev 25A, Overhead Annunciator Window Box C1, Operations Alarm Response Procedure, 10/30/2004 Project stage: Other ML0500600742004-11-0303 November 2004 Structural Integrity Associates, Inc. HC-06-301 Hope Creek Recirculation System Vibration Testing (Vtd 326747) 11/03/2004 Project stage: Other ML0432301632004-11-18018 November 2004 Expected Task Interface Agreement to Review B Recirculation Pump High Vibration Report Project stage: Other ML0500601102004-12-10010 December 2004 Design Change Package 80062466 Revision 2 Extended Power Uprate Piping Vibration Monitoring Installation Package, 12/10/2004 Project stage: Other ML0500501112004-12-12012 December 2004 H-1-FD-CEE-1879, Hope Creek HPCI Exhaust Piping Supports Analysis Reported Damage in RF12 Project stage: Other ML0501402322004-12-12012 December 2004 H-1-BB-MEE-1878, Rev 0, Hope Creek B Recirculation Pump Vibration Analysis, 12/12/2004 Project stage: Other ML0434801642004-12-13013 December 2004 Questions Regarding B Recirculation Pump High Vibrations and High Pressure Coolant Injection System Exhaust Damage Project stage: Request ML0435102792004-12-16016 December 2004 PSEG Preliminary Responses to NRC Staff Questions Project stage: Other ML0500504702004-12-16016 December 2004 H-1-BB-MEE-1878, Hope Creek B Recirculation Pump Vibration Analysis, Revision 1 Project stage: Other ML0435006452004-12-16016 December 2004 PSEGs Preliminary Responses to NRC Staff Questions Regarding B Recirculation Pump Vibration Project stage: Other ML0502100682004-12-17017 December 2004 Summary of Meeting with PSEG to Discuss B Recirculation Pump High Vibrations (TAC MC5111), Attendance Sheet Project stage: Meeting ML0500601142004-12-23023 December 2004 Design Change Package 80062466 Revision 3 Extended Power Uprate Piping Vibration Monitoring, Installation Package, 12/23/2004 Project stage: Other ML0500504662004-12-29029 December 2004 Startup Readiness Project stage: Other ML0436502962004-12-30030 December 2004 Public Availability and Docketing of Documents Project stage: Other ML0500600222004-12-30030 December 2004 B Recirculation Pump Stuffing Box Measurements Summary Project stage: Other ML0500602522004-12-30030 December 2004 Summary of Hope Creek Vibration Issues and Planned Actions Project stage: Other ML0500602562004-12-30030 December 2004 B Reactor Recirculation Pump Vibration Troubleshooting Summary Project stage: Other ML0501202552005-01-12012 January 2005 Response to Task Interface Agreement - TIA 2004-006, Request for Evaluation of Sargent and Lundy Report on Hope Creek B Reactor Recirculation Pump and PSEG Nuclear LLC Evaluation of High Pressure Coolant Injection System Exhaust Snubbers Project stage: Other ML0501203032005-01-12012 January 2005 Flowserve Response to NRC Questions Station B Recirculation Pump Project stage: Other ML0500301602005-01-19019 January 2005 Summary of Meeting with PSEG to Discuss B Recirculation Pump High Vibrations Project stage: Meeting 2004-12-10
[Table View] |
Text
December 16, 2004 MEMORANDUM TO: Darrell J. Roberts, Chief, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation FROM:
Daniel S. Collins, Senior Project Manager, Section Project Directorate I
/RA by R. Fretz for/
Division of Licensing Project Management Office of Nuclear Reactor Regulation
SUBJECT:
HOPE CREEK GENERATING STATION - PSEGS PRELIMINARY RESPONSES TO NRC STAFF QUESTIONS REGARDING B RECIRCULATION PUMP VIBRATION (TAC MC5111)
On December 17, 2004, NRC staff will be conducting a public meeting with representatives of PSEG, the licensed owner and operator of the Hope Creek Generating Station. The purpose of the meeting is to discuss PSEGs responses to NRC staff questions regarding Hope Creek B recirculation pump high vibrations and high pressure coolant injection system exhaust pipe damage issues. The document attached to this memo was provided informally by the licensee to assist the NRC staff in its inspection activities regarding the pump vibration issue and to facilitate technical discussions between NRC and PSEG. The document provides preliminary responses to NRC staff questions that had been verbally transmitted to the licensee. This memorandum and the attachment do not convey a formal response by the licensee or represent an NRC staff position.
Docket No. 50-354
Attachment:
As stated CONTACT: D. Collins, NRR 301-415-1427
December 17, 2004 MEMORANDUM TO: Darrell J. Roberts, Chief, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation FROM:
Daniel S. Collins, Senior Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation
SUBJECT:
HOPE CREEK GENERATING STATION - PSEGS PRELIMINARY RESPONSES TO NRC STAFF QUESTIONS REGARDING B RECIRCULATION PUMP VIBRATION (TAC MC5111)
On December 17, 2004, NRC staff will be conducting a public meeting with representatives of PSEG, the licensed owner and operator of the Hope Creek Generating Station. The purpose of the meeting is to discuss PSEGs responses to NRC staff questions regarding Hope Creek B recirculation pump high vibrations and high pressure coolant injection system exhaust pipe damage issues. The document attached to this memo was provided informally by the licensee to assist the NRC staff in its inspection activities regarding the pump vibration issue and to facilitate technical discussions between NRC and PSEG. The document provides preliminary responses to NRC staff questions that had been verbally transmitted to the licensee. This memorandum and the attachment do not convey a formal response by the licensee or represent an NRC staff position.
Docket No. 50-354
Attachment:
As stated CONTACT: D. Collins, NRR 301-415-1427 DISTRIBUTION PUBLIC PDI-2 R/F D. Collins C. Raynor Accession No: ML043500645 Office PDI-2/LA PDI-2/PM PDI-2/SC Name CRaynor RFretz for DCollins DRoberts Date 12/16/04 12/16/04 12/16/04 OFFICIAL RECORD COPY