05000361/LER-1982-114, Forwards LER 82-114/01T-0.Detailed Event Analysis Submitted

From kanterella
Jump to navigation Jump to search
Forwards LER 82-114/01T-0.Detailed Event Analysis Submitted
ML20027C956
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 10/19/1982
From: Ray H
SOUTHERN CALIFORNIA EDISON CO.
To: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
Shared Package
ML20027C957 List:
References
NUDOCS 8210280080
Download: ML20027C956 (2)


LER-1982-114, Forwards LER 82-114/01T-0.Detailed Event Analysis Submitted
Event date:
Report date:
3611982114R00 - NRC Website

text

)

s l

D

/*2 Ocr SLC 3

Southern California Edison Company y

S AN ONOPRE NUC LE A R GENER A TING S T A TION P.O. BOX 120 S AN CLEMENT E. C ALIFORNI A 92672 H. B. R AY vrtspwoNE sinvioN M AN AQt R "I

I' ' "

U. S. Nuclear Regulatory Commission Of fice of Inspection and Enforcement Regfon V 1450 Maria Lane, Suite 210 Walnut Creek, CA 945965368 Attention:

Mr. R. H. Engelken, Regional Administrator

Dear Sir:

4

Subject:

Docket No.30-361 Prompt Report and 14-Day Foilow-up Report Licensee Event Report No.82-114 San Onof re Nuclear Generating Station, Unit 2 This submittal is in accordance with the reporting requirements of Technical-Specifications 6.9.1.12.b to Operating License NPF-10 for San Onofre, Unit 2, and confirms our October 18, 1982 prompt notification to the NRC of a reportable occurrence involving Limiting Condition for Operations (LCO) 3.6.2.3 associated with the Containment Cooling System (CCS). This letter also represents the required follow-up report and forwards the associated Licensee Event Report (LER).

On ' October 17, 1982 while in Mode 4 during surveillance t'esting of containment cooling f ans in 'accordance with S023-3-3.13, containment cooling fan 2E-402 (Train B) failed to start after several attempts and was declared inoperable at 2000. At this time, both containment spray pumps were out of service for flushing of the system.

LCO 3.6.2.3 requires two_ independent groups of containment cooling fans to be operable in Mode 4.

The Action Statements associated with LCO 3.6.2.3 assume operability of the Containment Spray System (CSS),

contrary to LCO 3.6.2.1, which is applicable in Modes 1, 2 and 3 only.

Since LCO 3.6.2.3 and its ' associated Action Statements do not address the event of October 17,1982, LCO 3.0.3 was invoked.

8210280090 821019 78 -d{cQ PDR ADOCK 05000361 l

4 R. H. Engelken October 19, 1982 CCS Train A was returned to service at 2025 on October 17, 1982 allowing entry into LCO 3.6.2.3, Action Statement c.

Action Statement c requires that the Inoperable group of cooling -fans' be restored to operable status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or that plant cooldown be initiated. Fan 2E-402 was restored to operable status at 0900 on October 18, 1982, satisfying the LCO 3.6.2.3.

Investigation revealed that the cause of inoperability of containmeni cooling fan 2E-402 was a faulty breaker. Corrective action included replacement of the breaker.

In addition, a proposed change to the Technical Specifications is being initiated to make consistent the mode applicability for Technical Specifications 3.6.2.1 and 3.6.2.3. This was an isolated incident and no other corrective action is necessary. LER 82-114 addresses this event.

Public health and safety was not affected during this event, if there are any questions regarding the above, please contact me.

Sincerely, F6 In m