=Text=
{{#Wiki_filter:May 13, 2021 Brian Seawright Licensing Engineer Holtec International 1 Holtec Boulevard Camden, NJ 08104
{{#Wiki_filter:Brian Seawright Licensing Engineer Holtec International 1 Holtec Boulevard Camden, NJ 08104


==SUBJECT:==
==SUBJECT:==
Line 25: Line 25:


==Dear Mr. Seawright:==
==Dear Mr. Seawright:==
By a {{letter dated|date=March 20, 2019|text=letter dated March 20, 2019}} (Agencywide Documents Access and Management System (ADAMS) Accession No. ML19092A192), and supplemented on September 16, 2019 (ADAMS Accession No. ML19277G818), April 28, 2020 (ADAMS Accession No. ML20128J292),
By a {{letter dated|date=March 20, 2019|text=letter dated March 20, 2019}} (Agencywide Documents Access and Management System (ADAMS) Accession No. ML19092A192), and supplemented on September 16, 2019 (ADAMS Accession No. ML19277G818), April 28, 2020 (ADAMS Accession No. ML20128J292),
May 15, 2020 (ADAMS Accession No. ML20128J292), June 12, 2020 (ADAMS Accession No. ML20164A294), June 22, 2020 (ADAMS Accession No. ML20174A397), July 30, 2020 (ADAMS Accession No. ML20213C679), August 14, 2020 (ADAMS Accession No. ML20229A001),
May 15, 2020 (ADAMS Accession No. ML20128J292), June 12, 2020 (ADAMS Accession No. ML20164A294), June 22, 2020 (ADAMS Accession No. ML20174A397), July 30, 2020 (ADAMS Accession No. ML20213C679), August 14, 2020 (ADAMS Accession No. ML20229A001),
September 1, 2020 (ADAMS Accession No. ML20245E463), and September 25, 2020 (ADAMS Accession No. ML20269A425), Holtec International (Holtec) submitted an application in accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 72 for an amendment to Certificate of Compliance (CoC) No. 1014 for the HI-STORM 100 Multipurpose Canister (MPC) Storage System. Amendment No. 15 revises the certificate and technical specifications to 1) add a new version of a transfer cask and its applicable MPCs; 2) include MPC-32M for storage in the HI-STORM 100 System; 3) include MPC-32 Version 1 and MPC-68 Version 1 for storage in the HI-STORM 100 System; 4) add a new overpack; 5) add three additional boiling water reactor (BWR) fuel types to the approved content for MPC-68M; 6) lower the allowed ambient temperature from 80°F to 70°F for Version E overpack; 7) add HI-DRIP and dry ice jacket (DIJ) ancillary system as additional cooling when the MPC is loaded in the HI-TRAC transfer cask; 8) allow for partial gadolinium credit for BWR fuel assemblies types 10x10 and 11x11 assembly classes in MPC-68M; 9) include allowance for canisters currently loaded under earlier amendments which had different helium leak test requirements; 10) update Drawing No. 7195 for the MPC-68M by removing dimensions which are not used in the safety analysis; 11) include DIJ as an optional alternate cooling method for short-term operation of the loaded HI-TRAC. Amendment No. 15 also makes several clarifications and editorial and minor changes.
September 1, 2020 (ADAMS Accession No. ML20245E463), and September 25, 2020 (ADAMS Accession No. ML20269A425), Holtec International (Holtec) submitted an application in accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 72 for an amendment to Certificate of Compliance (CoC) No. 1014 for the HI-STORM 100 Multipurpose Canister (MPC) Storage System. Amendment No. 15 revises the certificate and technical specifications to 1) add a new version of a transfer cask and its applicable MPCs; 2) include MPC-32M for storage in the HI-STORM 100 System; 3) include MPC-32 Version 1 and MPC-68 Version 1 for storage in the HI-STORM 100 System; 4) add a new overpack; 5) add three additional boiling water reactor (BWR) fuel types to the approved content for MPC-68M; 6) lower the allowed ambient temperature from 80°F to 70°F for Version E overpack; 7) add HI-DRIP and dry ice jacket (DIJ) ancillary system as additional cooling when the MPC is loaded in the HI-TRAC transfer cask; 8) allow for partial gadolinium credit for BWR fuel assemblies types 10x10 and 11x11 assembly classes in MPC-68M; 9) include allowance for canisters currently loaded under earlier amendments which had different helium leak test requirements; 10) update Drawing No. 7195 for the MPC-68M by removing dimensions which are not used in the safety analysis; 11) include DIJ as an optional alternate cooling method for short-term operation of the loaded HI-TRAC. Amendment No. 15 also makes several clarifications and editorial and minor changes.
As stated in the Federal Register (86 FR 16291, March 29, 2021), the effective date of Amendment No. 15 to CoC No. 1014 is June 14, 2021. Attached are CoC No. 1014, Amendment No. 15, and the corresponding technical specifications and final safety evaluation report. This certificate constitutes the approval and conditions for the use of the HI-STORM 100 MPC Storage System for the storage of spent nuclear fuel under the general licensing provisions of 10 CFR 72.210.
As stated in the Federal Register (86 FR 16291, March 29, 2021), the effective date of Amendment No. 15 to CoC No. 1014 is June 14, 2021. Attached are CoC No. 1014, Amendment No. 15, and the corresponding technical specifications and final safety evaluation report. This certificate constitutes the approval and conditions for the use of the HI-STORM 100 MPC Storage System for the storage of spent nuclear fuel under the general licensing provisions of 10 CFR 72.210.
May 13, 2021


B. Seawright                                   If you have any questions regarding this certificate, please contact Yen-Ju Chen of my staff at (301) 415-1018.
B. Seawright If you have any questions regarding this certificate, please contact Yen-Ju Chen of my staff at (301) 415-1018.
Sincerely, Signed by McKirgan, John on 05/13/21 John B. McKirgan, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1014 CAC No.: 001208 EPID: L-2019-LLA-0059
Sincerely, John B. McKirgan, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1014 CAC No.: 001208 EPID: L-2019-LLA-0059


==Enclosures:==
==Enclosures:==
Line 42: Line 42:
: 6. CoC 1014, A15, App C
: 6. CoC 1014, A15, App C
: 7. CoC 1014, A15, App D
: 7. CoC 1014, A15, App D
: 8. CoC 1014, A15, Final SER
: 8. CoC 1014, A15, Final SER Signed by McKirgan, John on 05/13/21


ML21118A862; Ltr ML21118A863
ML21118A862; Ltr ML21118A863 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB*
* via email OFFICE               NMSS/DFM/STLB       NMSS/DFM/STLB*     NMSS/DFM/STLB       NMSS/DFM/STLB NAME                 YChen           YC WWheatley       WW JMcKirgan         JM YChen         YC DATE                 Apr 30, 2021         May 6, 2021       May 6, 2021         May 11, 2021 OFFICE               NMSS/DFM/STLB NAME                 JMcKirgan       JM DATE                 May 13, 2021}}
NMSS/DFM/STLB NMSS/DFM/STLB NAME YChen WWheatley JMcKirgan YChen DATE Apr 30, 2021 May 6, 2021 May 6, 2021 May 11, 2021 OFFICE NMSS/DFM/STLB NAME JMcKirgan DATE May 13, 2021}}

Latest revision as of 09:34, 29 November 2024

Issuance of Certificate of Compliance No. 1014, Amendment No. 15 for the HI-STORM 100 Multipurpose Canister Storage System
ML21118A863
Person / Time
Site: Holtec
Issue date: 05/13/2021
From: John Mckirgan
Storage and Transportation Licensing Branch
To: Seawright B
Holtec
YJChen NMSS/DFM/STL 301.415.1018
Shared Package
ML21118A862 List:
References
CAC 001208, EPID L-2019-LLA-0059
Download: ML21118A863 (3)


Text

Brian Seawright Licensing Engineer Holtec International 1 Holtec Boulevard Camden, NJ 08104

SUBJECT:

ISSUANCE OF CERTIFICATE OF COMPLIANCE NO. 1014, AMENDMENT NO. 15 FOR THE HI-STORM 100 MULTIPURPOSE CANISTER STORAGE SYSTEM (DOCKET NO. 72-1014, CAC NO. 001028, EPID: L-2019-LLA-0059)

Dear Mr. Seawright:

By a letter dated March 20, 2019 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML19092A192), and supplemented on September 16, 2019 (ADAMS Accession No. ML19277G818), April 28, 2020 (ADAMS Accession No. ML20128J292),

May 15, 2020 (ADAMS Accession No. ML20128J292), June 12, 2020 (ADAMS Accession No. ML20164A294), June 22, 2020 (ADAMS Accession No. ML20174A397), July 30, 2020 (ADAMS Accession No. ML20213C679), August 14, 2020 (ADAMS Accession No. ML20229A001),

September 1, 2020 (ADAMS Accession No. ML20245E463), and September 25, 2020 (ADAMS Accession No. ML20269A425), Holtec International (Holtec) submitted an application in accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 72 for an amendment to Certificate of Compliance (CoC) No. 1014 for the HI-STORM 100 Multipurpose Canister (MPC) Storage System. Amendment No. 15 revises the certificate and technical specifications to 1) add a new version of a transfer cask and its applicable MPCs; 2) include MPC-32M for storage in the HI-STORM 100 System; 3) include MPC-32 Version 1 and MPC-68 Version 1 for storage in the HI-STORM 100 System; 4) add a new overpack; 5) add three additional boiling water reactor (BWR) fuel types to the approved content for MPC-68M; 6) lower the allowed ambient temperature from 80°F to 70°F for Version E overpack; 7) add HI-DRIP and dry ice jacket (DIJ) ancillary system as additional cooling when the MPC is loaded in the HI-TRAC transfer cask; 8) allow for partial gadolinium credit for BWR fuel assemblies types 10x10 and 11x11 assembly classes in MPC-68M; 9) include allowance for canisters currently loaded under earlier amendments which had different helium leak test requirements; 10) update Drawing No. 7195 for the MPC-68M by removing dimensions which are not used in the safety analysis; 11) include DIJ as an optional alternate cooling method for short-term operation of the loaded HI-TRAC. Amendment No. 15 also makes several clarifications and editorial and minor changes.

As stated in the Federal Register (86 FR 16291, March 29, 2021), the effective date of Amendment No. 15 to CoC No. 1014 is June 14, 2021. Attached are CoC No. 1014, Amendment No. 15, and the corresponding technical specifications and final safety evaluation report. This certificate constitutes the approval and conditions for the use of the HI-STORM 100 MPC Storage System for the storage of spent nuclear fuel under the general licensing provisions of 10 CFR 72.210.

May 13, 2021

B. Seawright If you have any questions regarding this certificate, please contact Yen-Ju Chen of my staff at (301) 415-1018.

Sincerely, John B. McKirgan, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1014 CAC No.: 001208 EPID: L-2019-LLA-0059

Enclosures:

1. CoC 1014, A15, CoC
2. CoC 1014, A15, App A
3. CoC 1014, A15, App B
4. CoC 1014, A15, App A-100U
5. CoC 1014, A15, App B-100U
6. CoC 1014, A15, App C
7. CoC 1014, A15, App D
8. CoC 1014, A15, Final SER Signed by McKirgan, John on 05/13/21

ML21118A862; Ltr ML21118A863 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB*

NMSS/DFM/STLB NMSS/DFM/STLB NAME YChen WWheatley JMcKirgan YChen DATE Apr 30, 2021 May 6, 2021 May 6, 2021 May 11, 2021 OFFICE NMSS/DFM/STLB NAME JMcKirgan DATE May 13, 2021