HOLTEC INTERNATIONAL September 16, 201 9 Yen Chen, Project Manager Division of Spent Fuel Management Holtec Center, One Holtec Drive, Marlton, NJ 08053 Telephone (856) 797-0900 Fax(856)797-0909 Office of Nuclear Material Safety and Safeguards 72-- Jolt/
U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
Subject:
Reference:
HI-STORM 100 Amendment 15 Responses to Requests for Supplemental Information
[1] Holtec Letter 5014867, "HI-STORM 100 Multipurpose Canister Storage System Amendment 15 Request," dated March 20, 2019, from J. Tomlinson (Holtec) to J. McKirgan (NRC)
[2] NRC Letter, "Acceptance Review of Request for Amendment No. 15 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System (Docket No. 72-1014, CAC No. 001028, EPID: L-2019-LLA-0059) - Request for Supplement Information," dated July 9, 2019, from Y. Chen (NRC) to J. Tomlinson (Holtec)
Dear Ms. Chen,
Holtec appreciates the NRC staff review ofHoltec's application for Amendment No. 15 to the HI-STORM 100 System [1] and understands that supplemental information is needed [2]. This letter provides the responses to those requests in Attachment 1. Changes needed to the CoC and appendices as a result of these RSis are included as Attachments 2 through 6. Changes to the FSAR made as a result of these RSis are included in proprietary and non-proprietary versions as Attachments 7 and 8. Attachments 9 through 13 contain proprietary technical information to support the responses. Attachment 14 is an affidavit prepared in accordance with 10 CFR 2.390 requesting information contained in Attachments 7 and 9 through 13 be withheld from public disclosure.
In addition to the requested information, CoC Appendix B Table 2.1-3 and FSAR Table 2.Ill.3 were revised to correct the fuel pellet diameter, fuel rod pitch and channel thickness for the 1 OX 1 OJ fuel type.
If you have any questions, please contact me at (856)-797-0900 ext. 3765.
Document ID: 5014878 Page I of2
HOLTEC INTERNATIONAL Sincerely, Joyce Tomlinson Adjunct Licensing Manager Holtec International Holtec Center, One Holtec Drive, Marlton, NJ 08053 Telephone (856) 797 -0900 Fax (856) 797-0909 : HI-STORM 100 Amendment 15 RSI Responses (Non-proprietary) : HI-STORM 100 Amendment 15 Revised CoC (Non-proprietary) : HI-STORM 100 Amendment 15 Revised CoC Appendix A(Non-proprietary) : HI-STORM 100 Amendment 15 Revised CoC Appendix B(Non-proprietary) : HI-STORM 100 Amendment 15 Revised CoC Appendix C(Non-proprietary) : HI-STORM I 00 Amendment 15 Revised CoC Appendix D(Non-proprietary) : HI-STORM 100 FSAR PR 17.A, changed pages (Proprietary) : HI-STORM 100 FSAR PR 17.A, changed pages (Non-proprietary) : Holtec Report HI-2033039 Rev.5, "Critical Experiment Benchmark" (Proprietary) 0: Holtec Report Hl-2033039 Rev.5, "Critical Experiment Benchmark" Input/
Output files (Proprietary) 1: Holtec Report Hl-2043317 Rev. 36, "HI-STORM Themrnl-Hydraulic Analyses Supporting Up to 36.9 kW High Heat Load Amendment" (Proprietary) 2: Holtec Report HI-2188253 Rev.1, "HI-STORM lOOS Version E Shielding Analysis" (Proprietary) 3: Holtec Report HJ-2188480 Rev.0, "Lower Bound Fuel Enrichment Based on Industry Data" (Proprietary) 4: Affidavit Pursuant to 10 CFR 2.390 to Withhold Information from Public Disclosure cc (via email): Mike Layton, USNRC John McKirgan, USNRC Christian Jacobs, USNRC Document ID: 5014878 Page 2 of 2
U.S. Nuclear Regulatory Commission Document ID 5014878 Non-Proprietary Attachment 14 AFFIDAVIT PURSUANT TO 10 CFR 2.390 I, Kimberly Manzione, being duly sworn, depose and state as follows:
( 1)
I have reviewed the infonnation described in paragraph (2) which is sought to be withheld, and am authorized to apply for its withholding.
(2)
The information sought to be withheld is information provided in Attachments 7 and Attachments 9 through 13 to Holtec Letter 5014878. These enclosures contain Holtec Proprietary information.
(3)
In making this application for withholding of proprietary information of which it is the owner, Holtec International relies upon the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC Sec. 552(b)(4) and the Trade Secrets Act, 18 USC Sec. 1905, and NRC regulations 10CFR Part 9.17(a)(4), 2.390(a)(4), and 2.390(b)(l) for "trade secrets and commercial or financial information obtained from a person and privileged or confidential" (Exemption 4 ). The material for which exemption from disclosure is here sought is all "confidential commercial information", and some portions also qualify under the narrower definition of "trade secret",
within the meanings assigned to those terms for purposes ofFOIA Exemption 4 in, respectively, Critical Mass Energy Project v. Nuclear Regulatory Commission, 975F2d871 (DC Cir. 1992), and Public Citizen Health Research Group v. FDA, 704F2dl280 (DC Cir. 1983).
1 of 5
U.S. Nuclear Regulatory Commission Document ID 5014878 Non-Proprietary Attachment 14 AFFIDAVIT PURSUANT TO 10 CFR 2.390
( 4)
Some examples of categories of infonnation which fit into the definition of proprietary infonnation are:
- a.
Information that discloses a process, method, or apparatus, including supporting data and analyses, where prevention of its use by Holtec's competitors without license from Holtec International constitutes a competitive economic advantage over other companies;
- b.
Information which, if used by a competitor, would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product.
- c.
Information which reveals cost or price information, production, capacities, budget levels, or commercial strategies of Holtec International, its customers, or its suppliers;
- d.
Information which reveals aspects of past, present, or future Holtec International customer-funded development plans and programs of potential commercial value to Holtec International;
- e.
Information which discloses patentable subject matter for which it may be desirable to obtain patent protection.
The information sought to be withheld is considered to be proprietary for the reasons set forth in paragraphs 4.a, 4.b, and 4.e above.
( 5)
The information sought to be withheld is being submitted to the NRC in confidence. The information (including that compiled from many sources) is of a sort customarily held in confidence by Holtec International, and is in fact so held. The information sought to be withheld has, to the best of my knowledge and belief, consistently been held in confidence by Holtec International. No public disclosure has been made, and it is not available in public sources. All disclosures to third parties, including any required transmittals to the NRC, have been made, or must be made, pursuant to regulatory provisions or proprietary agreements which provide for 2 of 5
U.S. Nuclear Regulatory Commission Document ID 5014878 Non-Proprietary Attachment 14 AFFIDAVIT PURSUANT TO 10 CFR 2.390 maintenance of the information in confidence. Its initial designation as proprietary information, and the subsequent steps taken to prevent its unauthorized disclosure, are as set forth in paragraphs ( 6) and (7) following.
( 6)
Initial approval of proprietary treatment of a document is made by the manager of the originating component, the person most likely to be acquainted with the value and sensitivity of the information in relation to industry knowledge. Access to such documents within Holtec International is limited on a "need to know" basis.
(7)
The procedure for approval of external release of such a document typically requires review by the staff manager, project manager, principal scientist or other equivalent authority, by the manager of the cognizant marketing function ( or his designee ), and by the Legal Operation, for technical content, competitive effect, and determination of the accuracy of the proprietary designation. Disclosures outside Holtec International are limited to regulatory bodies, customers, and potential customers, and their agents, suppliers, and licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or proprietary agreements.
(8)
The information classified as proprietary was developed and compiled by Holtec International at a significant cost to Holtec International. This information is classified as proprietary because it contains detailed descriptions of analytical approaches and methodologies not available elsewhere. This information would provide other parties, including competitors, with information from Holtec Intemational's technical database and the results of evaluations performed by Holtec International. A substantial effort has been expended by Holtec International to develop this information.
Release of this information would improve a competitor's position because it would enable Holtec's competitor to copy our technology and offer it for sale in competition with our company, causing us financial injury.
3 of 5
U.S. Nuclear Regulatory Commission Document ID 5014878 Non-Proprietary Attachment 14 AFFIDAVIT PURSUANT TO 10 CFR 2.390 (9)
Public disclosure of the information sought to be withheld is likely to cause substantial harm to Holtec International's competitive position and foreclose or reduce the availability of profit-making opportunities. The infonnation is part of Holtec International's comprehensive spent fuel storage technology base, and its commercial value extends beyond the original development cost.
The value of the technology base goes beyond the extensive physical database and analytical methodology, and includes development of the expertise to determine and apply the appropriate evaluation process.
The research, development, engineering, and analytical costs comprise a substantial investment of time and money by Holtec International.
The precise value of the expertise to devise an evaluation process and apply the correct analytical methodology is difficult to quantify, but it clearly is substantial.
Holtec International's competitive advantage will be lost if its competitors are able to use the results of the Holtec International experience to normalize or verify their own process or if they are able to claim an equivalent understanding by demonstrating that they can arrive at the same or similar conclusions.
The value of this information to Holtec International would be lost if the information were disclosed to the public. Making such information available to competitors without their having been required to undertake a similar expenditure of resources would unfairly provide competitors with a windfall, and deprive Holtec International of the opportunity to exercise its competitive advantage to seek an adequate return on its large investment in developing these very valuable analytical tools.
4 of5
U.S. Nuclear Regulatory Commission Document ID 5014878 Non-Proprietary Attachment 14 AFFIDAVIT PURSUANT TO 10 CFR 2.390 ST A TE OF NEW JERSEY COUNTY OF CAMDEN
)
)
)
ss:
Kimberly Manzione, being duly sworn, deposes and says:
That she has read the foregoing affidavit and the matters stated therein are true and correct to the best of her knowledge, information, and belief.
Executed at Camden, New Jersey, this 16th day of September, 2019.
5 of 5 lj~
Kimberly Manzione Licensing Manager Holtec International Erika randrimo NOTARY PUBLIC ST<\\TE OF NEW JERSEY 7 '>Q11
\\ 1Y C0\\1\\11SS\\ON EXPIRES January I, ~ ~-
- ---- ----