CAC:001208, (Approved, Closed) EPID:L-2023-LLA-0110, License Amendment Request to Revise ISFSI Technical Specification 4.4 to Allow Use of a Code Alternative to ASME Code, NB-5130, Examination of Weld Edge Preparation Surfaces, for the TN-40HT (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance
Results
Other: ML19158A272, ML19158A273, ML19158A274, ML19158A275, ML19158A276, ML20295A413, ML20295A415, ML20295A416, ML20295A417, ML20295A418, ML20295A419, ML20295A420, ML20295A421, ML20329A323, ML21118A864, ML21118A865, ML21118A866, ML21118A867, ML21118A868, ML21118A869, ML21118A870, ML21168A352, ML21168A353, ML21168A354, ML21168A355, ML21168A356, ML21168A357, ML21168A358, ML21168A359, ML21168A361, ML21168A362, ML21168A363, ML21168A364, ML21237A177, ML23074A102, ML24010A058, ML24010A061, ML24095A040, ML24095A041, ML24095A042, ML24095A043, ML24095A044, ML24095A045, ML24095A046, ML24095A047, ML24179A264, ML24179A265, ML24179A266, ML24179A267, ML24179A268... further results
|
MONTHYEARML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18134A1112018-05-15015 May 2018 Enclosure 1: Rsi (Non-Proprietary) (Letter to J. Bondre Acceptance Review of Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 1 to NUHOMS Eos System (Docket No. 72-1042, CAC No. 001028, EPID: L-2018-LLA-0043 Project stage: Acceptance Review ML18134A1102018-05-15015 May 2018 Letter to J. Bondre Acceptance Review of Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 1 to NUHOMS Eos System (Docket No. 72-1042, CAC No. 001028, EPID: L-2018-LLA-0043) - Request for Supplemental Informa Project stage: Acceptance Review ML18179A1042018-06-15015 June 2018 Attachment 1 - Summary of Proposed Changes - LAR 1032-5 Project stage: Request ML18213A0382018-08-0101 August 2018 Enclosursi (Letter to P. Narayanan Acceptance Review (Continued) of Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 1 to NUHOMS Eos System (Docket No. 72-1042, CAC No. 001028, EPID: L-2018-LLA-0043) Project stage: Acceptance Review ML18213A0372018-08-0101 August 2018 Letter to P. Narayanan Acceptance Review (Continued) of Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 1 to NUHOMS Eos System (Docket No. 72-1042, CAC No. 001028, EPID: L-2018-LLA-0043) - Request for Suppl Project stage: Acceptance Review ML18268A1392018-09-20020 September 2018 Modification to Requested Changes on HI-STORM FW Amendment 5 Request Project stage: Request ML18355A8632018-12-21021 December 2018 Letter to P. Narayanan Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 1, to NUHOMS Eos System (Docket No. 72-1042, CAC No. 001028, EPID: L-2018-LLA-0043) - Request for Additional Information Project stage: RAI ML18355A8642018-12-21021 December 2018 Enclosure 1 - RAI (Non-Proprietary) (Letter to P. Narayanan Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 1, to NUHOMS Eos System (Docket No. 72-1042, CAC No. 001028, EPID: L-2018-LLA-0043) - Request for Project stage: RAI ML19046A0642019-02-13013 February 2019 Letter to J. Tomlinson Acceptance Review of Request for Amendment No. 5 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Cask System (W/Enclosure) Project stage: Acceptance Review ML19178A1242019-06-28028 June 2019 Enclosure 1: Rsi (non-proprietary) (Letter to P. Narayanan Acceptance Review of Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 2 NUHOMS Eos System (Dkt: 72-1042, CAC: 001028, EPID: L-2019-LLA-0078)) Project stage: Acceptance Review ML19178A1232019-06-28028 June 2019 Letter to P. Narayanan Acceptance Review of Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 2 NUHOMS Eos System (Dkt: 72-1042, CAC: 001028, EPID: L-2019-LLA-0078) Request for Supplemental Information Project stage: Acceptance Review ML19182A0602019-07-0909 July 2019 Letter to J. Tomlinson Acceptance Review of Request for Amendment No. 15 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System - Request for Supplemental Information (W/Enclosure) Project stage: Acceptance Review ML19247B7182019-09-0303 September 2019 Letter to J. Tomlinson Amendment No. 5 to Certificate of Compliance No. 1023 for the HI-STORM Flood/Wind Multipurpose Canister Storage System - Request for Additional Information (W/Enclosure 1) Project stage: RAI ML19158A2742019-12-20020 December 2019 Enclosure 2: Proposed CoC 1032 Amendment No. 4 Appendix a (Memorandum to J. Cai User Need for Rule Making for the Holtec HI-STORM Flood-Wind Multipurpose Canister Storage System, Amendment No. 4) Project stage: Other ML19158A2732019-12-20020 December 2019 Enclosure 1: Proposed CoC 1032 Amendment No. 4 (Memorandum to J. Cai User Need for Rule Making for the Holtec HI-STORM Flood-Wind Multipurpose Canister Storage System, Amendment No. 4) Project stage: Other ML19158A2762019-12-20020 December 2019 Enclosure 4: Preliminary CoC 1032 Amendment No. 4 SER (Memorandum to J. Cai User Need for Rule Making for the Holtec HI-STORM Flood-Wind Multipurpose Canister Storage System, Amendment No. 4) Project stage: Other ML19158A2722019-12-20020 December 2019 Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM Flood-Wind Multipurpose Canister Storage System, Amendment No. 4 Project stage: Other ML19158A2752019-12-20020 December 2019 Enclosure 3: Proposed CoC 1032 Amendment No. 4 Appendix B (Memorandum to J. Cai User Need for Rule Making for the Holtec HI-STORM Flood-Wind Multipurpose Canister Storage System, Amendment No. 4) Project stage: Other ML20128J2922020-04-27027 April 2020, 28 April 2020 International, Submittal of Responses to Nrc,S 1st Round RAIs for HI-STORM 100 Amendment Number 15 Project stage: Request ML20128J2932020-04-28028 April 2020 International, Submittal of Responses to Nrc,S 1st Round RAIs for HI-STORM 100 Amendment Number 15 Project stage: Request ML20136A4752020-05-15015 May 2020 Holtec International Submittal of Responses to Nrc'S RAIs 3-1 and 3-6 for HI-STORM 100 Amendment Number 15 Project stage: Request ML20164A2942020-06-12012 June 2020 International Submittal of Supplemental Information to RAI 8-1 Response for HI-STORM 100 Amendment Number 15 Project stage: Request ML20245E4632020-09-0101 September 2020 International - Submittal of Supplemental Information on HI-STORM 100 Amendment 15 Project stage: Request ML20269A4252020-09-25025 September 2020 International - Submittal of Supplemental Information on HI-STORM 100 Amendment 15 Project stage: Request ML20318A3212020-11-13013 November 2020 Submittal of Clarification RAI Responses on HI-STAR 100 License Renewal Project stage: Request ML20329A3232020-11-24024 November 2020 International, Clarification RAI Responses on HI-STAR 100 License Renewal Updated Project stage: Other ML20295A4182021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 Appendix C Project stage: Other ML20295A4222021-01-27027 January 2021 Preliminary CoC 1014 Amendment No. 15 Safety Evaluation Report Project stage: Approval ML20295A4162021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 Appendix a Project stage: Other ML20295A4192021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 Appendix D Project stage: Other ML20295A4172021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 Appendix B Project stage: Other ML20295A4202021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 Appendix A-100U Project stage: Other ML20295A4152021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 for Holtec Intl Project stage: Other ML20295A4212021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 Appendix B-100U Project stage: Other ML20295A4132021-01-27027 January 2021 User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 15 Project stage: Other ML21068A3612021-03-0909 March 2021 International, Submittal of HI-STORM 100 Multipurpose Canister Storage System Amendment 16 Request Project stage: Request ML21118A8662021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15, Appendix B, Approved Contents and Design Features for the Hi-Storm 100 Cask System Project stage: Other ML21118A8642021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15 Project stage: Other ML21118A8652021-05-13013 May 2021 Certificate of Compliance 1014, Amendment No. 15, Appendix a Technical Specifications for the Hi-Storm 100 Cask System Project stage: Other ML21118A8672021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15, Appendix C, Technical Specifications for the Hi-Storm 100S Version E Cask Project stage: Other ML21118A8702021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15, Appendix B-100U Approved Contents and Design Features for the Hi-Storm 100 Cask System (Model No. 100U Addition) Project stage: Other ML21118A8632021-05-13013 May 2021 Issuance of Certificate of Compliance No. 1014, Amendment No. 15 for the HI-STORM 100 Multipurpose Canister Storage System Project stage: Approval ML21118A8712021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15. Final Safety Evaluation Report Project stage: Approval ML21118A8682021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15, Appendix D, Approved Contents and Design Features for the Hi-Storm 100S Version E Cask and Hi-Trac Ms Project stage: Other ML21118A8692021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15, Appendix A-100U Technical Specifications for the Hi-Storm 100 Cask System (Model N. 100U Addition) Project stage: Other ML21168A3522021-06-28028 June 2021 User Need Memo for Renewal of CoC No. 1008 (HI-STAR 100) Project stage: Other ML21168A3512021-06-28028 June 2021, 9 September 2021 Rulemaking for the Renewal of CoC No. 1008, HI-STAR 100 Cask System Project stage: Request ML21179A1792021-07-12012 July 2021 Acceptance Review of Request for Amendment No. 16 to Certificate of Compliance No. 1014 for HI-STORM 100 Multipurpose Canister Storage System, Request for Supplemental Information Project stage: Acceptance Review 2020-11-13
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 5, 2024 Thomas A. Conboy, Site Vice President Prairie Island Nuclear Generating Co.
Northern States Power Co. - Minnesota 1717 Wakonade Drive East Welch, MN 55089-9642
SUBJECT:
AMENDMENT NO. 12 TO MATERIALS LICENSE NO. SPECIAL NUCLEAR MATERIAL-2506 FOR THE PRAIRIE ISLAND INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ENTERPRISE PROJECT IDENTIFIER NO. L-2023-LLA-0110)
Dear Thomas Conboy:
By [[letter::L-PI-23-018, License Amendment Request to Revise ISFSI Technical Specification 4.4 to Allow Use of a Code Alternative to ASME Code, NB-5130, Examination of Weld Edge Preparation Surfaces, for the TN-40HT|letter dated July 14, 2023]], Northern States Power Company (NSPM) submitted proposed Amendment No. 12 to Special Nuclear Materials (SNM) License No. 2506 for the Prairie Island Independent Spent Fuel Storage Installation. The application proposed to amend the technical specifications (TS) of SNM License No. 2506, to allow use of a code alternate needed to provide additional non-destructive examination options during fabrication of the TN-40HT casks at the PI ISFSI by allowing use of an equivalent method for examination of weld edge preparation surfaces.
The U.S. Nuclear Regulatory Commission (NRC) staff reviewed the NSPM application and finds reasonable assurance that: (i) the activities authorized by the amended license can be conducted without endangering the health and safety of the public, and (ii) these activities will be conducted in compliance with the applicable regulations. The NRC staff further finds the issuance of the amendment will not be inimical to the common defense and security. In addition, the staff determined that issuance of Amendment No. 12 meets the criteria for a categorical exclusion in Title 10 of the Code of Federal Regulations (10 CFR) Section 51.22(c)(11).
Therefore, the staff will not prepare an environmental assessment or environmental impact statement.
The NRC staff approved the requested license amendment and revised section 4, Design Features, of the TS. The attached amended license supersedes License No. SNM-2506 dated October 29, 2020. Changes made to the attached license and TS pages are indicated by vertical lines in the right margin. The safety evaluation report and the draft Federal Register notice of issuance for the amended license are also attached.
In accordance with 10 CFR 2.390, Public inspections, exemptions, requests for withholding, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room (PDR) or from the Publicly Available Records component of the NRCs Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html. The PDR is open by appointment. To make an appointment to visit the PDR, please send an email to
T. Conboy 2
PDR.Resource@nrc.gov or call 1-800-397-4209 or 301-415-4737, between 8 a.m. and 4 p.m.
eastern time (ET), Monday through Friday, except Federal holidays.
If you have any questions regarding this matter, you may contact me at (301) 415-8064 or you may contact John-Chau Nguyen of my staff at (301) 415-0262.
Sincerely, Yoira Diaz-Sanabria, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-10 CAC No.: 001028 EPID No.: L-2023-LLA-0110
Enclosures:
- 1. Materials License No. SNM-2506 Amendment No. 12
- 2. PI ISFSI Technical Specifications, Section 4
- 3. Safety Evaluation Report
- 4. Draft Federal Register Notice of Issuance of Amendment Signed by Diaz-Sanabria, Yoira on 03/05/24
ML24008A128 (pkg); ML24010A058 (ltr); ML24008A130 (encl 1);
ML24008A129 (encl 2); ML24008A131 (encl 3); ML24010A061 (encl 4: draft FRN)
OFFICE DFM DFM DFM DFM NAME JNguyen WWheatley LHowe ELove DATE 1/22/2024 1/25/2024 2/6/2024 1/25/2024 OFFICE DFM DFM OGC DFM NAME TBoyce HRodriguez EDuncan YDiaz-Sabrania DATE 2/7/2024 2/9/2024 3/4/2024 3/5/2024