TAC:69131
From kanterella
Jump to navigation
Jump to search
Request for: Open | |
Initiation
| |
| From | |
MONTHYEARML20247E7151989-05-17017 May 1989
[table view]Forwards Request for Addl Info to Enable NRC & Contractor (Viking Sys Intl) to Continue Review of Responses to Generic Ltr 88-01 Re IGSCC in BWR Austenitic Stainless Steel Piping.Response Requested in 60 Days of Ltr Receipt NLS8900265, Responds to NRC 890517 Request for Addl Info Re Generic Ltr 88-01, IGSCC in BWR Austenitic Stainless Steel Piping. Accepts NRC Staff Positions on Processes,Water Chemistry, Weld Overlay,Clamping Devices & Sample Expansion1989-07-24024 July 1989 Responds to NRC 890517 Request for Addl Info Re Generic Ltr 88-01, IGSCC in BWR Austenitic Stainless Steel Piping. Accepts NRC Staff Positions on Processes,Water Chemistry, Weld Overlay,Clamping Devices & Sample Expansion ML20011E8921990-02-14014 February 1990 Advises That 890803,1219 & 0724 Responses to Generic Ltr 88-01 Acceptable W/Listed Exceptions.Safety Evaluation of Responses & Contractor Technical Evaluation Rept Also Encl. W/O Stated Encls NLS9100172, Requests Clarification Re Insp of RWCU Piping in NRC ,Per Generic Ltr 88-01.Util Revised Commitment to Replace All RWCU Piping & Welds W/Matls Resistant to IGSCC1991-03-14014 March 1991 Requests Clarification Re Insp of RWCU Piping in NRC ,Per Generic Ltr 88-01.Util Revised Commitment to Replace All RWCU Piping & Welds W/Matls Resistant to IGSCC 1989-07-24 | |