I
05000387/LER-2016-019, Regarding Pressure Boundary Leakage from an Inadequate Weld Repair in Small Bore Pump Seal Vent Piping +, 05000387/LER-2016-020, Regarding Reactor Coolant Pressure Boundary Leakage at LPRM Housing as a Result of IGSCC +, 05000387/LER-2016-018, Regarding Inoperability of RCIC Due to an Oil Leak +
05000259/LER-2016-002, Regarding High Pressure Coolant Injection Safety System Functional Failure Due to Inoperability of Primary Containment Isolation Valve +, 05000260/LER-2016-002, Regarding High Pressure Coolant Injection System Failure Due to Stuck Contactor +, 05000260/LER-2016-001, Regarding High Pressure Coolant Injection Safety System Functional Failure Due to a Blown Fuse and a Failed Relay +, …
05000285/LER-2012-009, Regarding Inoperable Equipment Due to Lack of Environmental Qualifications +, 05000285/LER-2013-019, Regarding Non-Seismic Circulating Water Pipe Could Disable Raw Water Pumps +, 05000285/LER-2014-004, Regarding Unqualified Limit Switches Render Safety Equipment Inoperable +, …
05000348/LER-2016-006, Regarding Manual Reactor Trip Due to Loss of Speed Control on 1A Steam Generator Feed Pump +, 05000348/LER-2016-003, Regarding Pressurizer Safety Valve Setpoint Pressure Outside of Technical Specification Tolerance Band +, 05000348/LER-2016-002, Regarding Automatic Reactor Trip and Safety Injection Due to Closure of Main Steam Isolation Valve +
05000458/LER-2015-008, Of River Bend Station, Unit 1, Regarding Loss of Safety Function of High Pressure Core Spray Due to Failure of Main Control Building Ventilation Chiller +, 05000458/LER-2015-007, Unit 1 Regarding Potential Loss of Safety Function of High Pressure Core Spray Due to Failure of Main Control Building Ventilation Chiller +
05000315/LER-2015-004, Regarding Power Operated Relief Valve Technical Specification 3.4.11 Violation +, 05000315/LER-2016-002, Regarding Rod Position Indication Inoperable Longer than Allowed by Technical Specifications +, 05000316/LER-2016-001, Regarding Manual Reactor Trip Due to Moisture Separator Heater Expansion Joint Failure +, …
05000341/LER-2017-002, Regarding High Water Level Indications at Low Reactor Pressures Causes Some Functions of High Pressure Coolant Injection System and Reactor Core Isolation Cooling System to Be Inoperable +, 05000341/LER-2016-015, Regarding Secondary Containment Pressure Exceeded Technical Specification During Reactor Building HVAC Restart Due to High Winds +, 05000341/LER-2016-016, Regarding Secondary Containment Pressure Exceeded Technical Specification Due to Adverse Weather +, …
05000528/LER-2012-004, Regarding Essential Spray Pond Pump Actuation Due to a Control Room Essential Filtration Actuation Signal +, 05000529/LER-2012-003, Regarding Entry Into Mode 3 with One Auxiliary Feedwater Train Inoperable +, 05000529/LER-2012-002, Regarding Condition Prohibited by Technical Specification Due to Low Pressure Safety Injection System Drain Pipe Leak +, …