ML21278A116
Text
Rev. 18 A
REACTOR COOLANT PUMP FLOW TEST INSTRUMENTATION
~RSCHEL TYPE 24" x 17 1/2'~ VENTURI
.-~~~~~~~~~~
BARTON MOD 200..._ _
No. I, 0-20 psi t 0.5% F.S.
BARTON MOD 2 No.~ 0-20 psi
- 0.5% F.S.
BARTON MOD 200 No.4, 0-15 psi
+/-0.5% F.S.
BARTON MOD 200 No.33898, 0-15 psi..._ _
+/-0.5% F.S.
ROYLYN No. 5 0-3000 psi
- O. 25o/o...
- BARTON MOD 227 1o----i 0-150 psid i: 0.5% F.S.
CROSBY No. 4 0-3000 psi t 0.5% F.S.
BALTIMORE GAS & ELECTRIC CO.
Calvert Cliffs Nuclear Power Plant REACTOR COOLANT PUMP FLOW TEST INSTRUMENTATION Figure A Rev.18
Rev. 18 B
ERROR IN ESTABLISHMENT OF FLOW TRUE PUMP CASE AP MEASURED TEST LOOP AP
+ 0.5% FS =
+ 0. 75 PSI AP* 85 PSI AP.. 85
- 6. p INDIVIDUAL PUMP
.__._!o1oo1~ CURVE I
I I
I I
I I
I I
I
'f \\
92 500
.)
94, 940
~
I
!::. p = 85 - (Q.005) 85 PSI TRUE TEST LOOP FLOW" TRUE.
REACTOR COOLANT SYSTEM FLOW VENTURI t::.P
+ 1%0F THEORETICAL MEASURED VENTURI AP
- !: 2.5%
OF READING t
. CALCULATED TEST LOOP FLOW ALLOWANCE FOR PUMP CASE AREA VARIATION 840 GPM APPARENT REACTOR COOLANT SYSTEM FLOW, WORST CASE ERRORS MEASURED PUMP A P IN REACTOR COOLANT SYSTEM
- !: 0.5% OF READING t::.Pmin 84.57 PSI'------~
Q = 92,500 ~PM t::,. Pc( 8. 64 x 109
+ (. 02518. 64 xl09 A Pm~x B. 86 x 109 Q=./4E T
Q.)s.86x109 qr.ax 94, 100 GPM Offiax94, 940 GPM 0niax = 96,100 GPM Figure B BALTIMORE GAS & ELECTRIC CO.
Calvert Cliffs Nuclear Power Plant ERROR IN ESTABLISHMENT OF FLOW Rev. 18