ES-401 Written Examination Review Worksheet Form ES-401-9 Q
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
Source (B/M/N)
- 7.
Status (U/E/S)
- 8. Explanation Stem Focus Cues T/F Cred.
Dist Partial Job-Link Minutia
- /Units Backward Q -
K/A SRO Only 1
H 1
N U
LOD1, replaced question 2
F 3
B E
Removed resulting in a reactor trip from stem 3
H 3
B S
4 H
3 N
S 5
H 3
N S
Changed stem to have applicant diagnose Loss of Offsite power instead of being told that here is a loss of offsite power. P13001 is lost 6
H 3
N S
7 H
3 N
S 8
H 3
X B
U A2 and C2 implausible and cued answer in stem..Rewrote stem to in the CCW system instead of into the CCW system.
Refer to Section D of ES-401 and Appendix B for additional information regarding each of the following concepts:
- 1.
Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.
- 2.
Enter the level of difficulty (LOD) of each question a 1 (easy) to 5 (difficult); questions with a difficulty between 2 and 4 are acceptable.
- 3.
Check the appropriate box if a psychometric flaw is identified:
Stem Focus: The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).
Cues: The stem or distractors contain cues (e.g., clues, specific determiners, phrasing, length).
T/F: The answer choices are a collection of unrelated true/false statements.
Cred. Dist.: The distractors are not credible; single implausible distractors should be repaired, and more than one is unacceptable.
Partial: One or more distractors are partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by the stem).
- 4.
Check the appropriate box if a job content flaw is identified:
Job Link: The question is not linked to the job requirements (i.e., the question has a valid K/A but, as written, is not operational in content).
Minutia: The question requires the recall of knowledge that is too specific for the closed-reference test mode (i.e., it is not required to be known from memory).
- /Units: The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).
Backward: The question requires reverse logic or application compared to the job requirements.
- 5.
Check questions that are sampled for conformance with the approved K/A and those K/As that are designated SRO-only. (K/A and license-level mismatches are unacceptable.)
- 6.
Enter questions source: (B)ank, (M)odified, or (N)ew. Verify that (M)odified questions meet the criteria of Form ES-401, Section D.2.f.
- 7.
Based on the reviewers judgment, is the question, as written, (U)nsatisfactory (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?
- 8.
At a minimum, explain any U status ratings (e.g., how the Appendix B psychometric attributes are not being met).
ES-401 2
Form ES-401-9 Q
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
Source (B/M/N)
- 7.
Status (U/E/S)
- 8. Explanation Stem Focus Cues T/F Cred.
Dist Partial Job-Link Minutia
- /Units Backward Q -
K/A SRO Only 9
H 2
X N
U A2 and C2 are implausible - Heater bank 2 handswitch is in OFF as stem indicated, so they cant auto energize.
Rewrote stem to describe a power supply failure to Prop Heater Bank #2 10 F
3 B
E Removed will mitigate the ATWS from stem Rewrote distractor C to change borate amount to more plausible number (2000 ppm) 11 F
2 B
S 12 F
2 B
E Changed stem to what sensor is used to differentiate 13 F
3 B
E Removed RO is verifying natural circulation Question is Low Cog, not Hi Cog 14 H
3 B
S 15 H
3 N
S 16 H
2 N
S 17 F
3 N
S 18 H
3 B
E Added to distractors B and D to have a heat removal strategy.
19 F
2 N
E Will change 4th bullet to describe one CEA (CEA #1) continues to withdraw 20 F
2 N
S 21 H
3 N
S 22 H
3 N
S 23 H
2 N
S 24 H
3 N
S
ES-401 3
Form ES-401-9 Q
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
Source (B/M/N)
- 7.
Status (U/E/S)
- 8. Explanation Stem Focus Cues T/F Cred.
Dist Partial Job-Link Minutia
- /Units Backward Q -
K/A SRO Only 25 F
3 N
S 26 H
3 N
S 27 F
2 N
S 28 H
3 B
E Shortened to 2 cases, and removed Column B 29 H
2 N
S 30 F
1 N
S 31 H
3 B
S 32 F
2 N
S 33 F
2 B
S 34 H
2 B
S 35 F
2 N
S 36 H
2 N
S 37 F
2 B
S 38 H
2 N
E Add has/ to have in part 2 of the stem.
39 H
3 B
S 40 H
3 N
E Removed second to last sentence in stem stating With the given conditions..
Separate distractors into two numbered parts.
ES-401 4
Form ES-401-9 Q
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
Source (B/M/N)
- 7.
Status (U/E/S)
- 8. Explanation Stem Focus Cues T/F Cred.
Dist Partial Job-Link Minutia
- /Units Backward Q -
K/A SRO Only 41 H
3 N
S 42 F
3 N
S 43 H
3 X
B E
Added to stem per Caution in OI-8E 44 F
3 B
S 45 H
3 N
S 46 F
2 N
S 47 F
3 B
S 48 F
2 N
S 49 H
3 B
S 50 F
3 B
S 51 H
2 B
S 52 F
2 B
S 53 H
3 B
S 54 F
2 N
S 55 H
3 B
S 56 H
3 N
E Wrote out PZR 57 H
2 B
S
ES-401 5
Form ES-401-9 Q
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
Source (B/M/N)
- 7.
Status (U/E/S)
- 8. Explanation Stem Focus Cues T/F Cred.
Dist Partial Job-Link Minutia
- /Units Backward Q -
K/A SRO Only 58 H
2 N
E Added what the failure was. Edited plausibility statement.
59 H
3 M
S 60 H
3 B
S 61 H
3 B
S 62 H
2 M
S 63 F
3 N
S 64 H
3 N
S 65 F
3 N
S 66 F
2 N
E Removed first sentence in stem 67 F
3 N
S 68 F
2 B
E Added details to stem about RO and what his responsibilities are to better match KA 69 F
2 F
S 70 F
2 B
S 71 H
3 B
S 72 F
3 B
S 73 F
2 B
S 74 F
3 N
S
ES-401 6
Form ES-401-9 Q
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
Source (B/M/N)
- 7.
Status (U/E/S)
- 8. Explanation Stem Focus Cues T/F Cred.
Dist Partial Job-Link Minutia
- /Units Backward Q -
K/A SRO Only 75 F
2 B
S 76 H
3 N
S 77 H
1 X
N E
The TS is provided as a reference, as well as which TS to use is listed in the stem. Question is borderline DLU and as a result, LOD1.
78 F
2 B
E Change 150% to 125% to make more plausible in B2 and C2 79 H
3 B
E A2 and B2, made chargers plural 80 H
3 B
S 81 H
3 N
S 82 H
3 B
S 83 H
3 N
E A1 and D1 are implausible since stem says what is the expected effect. A1 and D1 describe no effect.
Added if any to effect in stem 84 F
2 N
S 85 H
3 B
S 86 F
3 N
E Added LCO(s) so it doesnt imply plural only.
87 F
3 N
S 88 H
3 N
S 89 F
3 N
S 90 H
2 N
S
ES-401 7
Form ES-401-9 Q
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
Source (B/M/N)
- 7.
Status (U/E/S)
- 8. Explanation Stem Focus Cues T/F Cred.
Dist Partial Job-Link Minutia
- /Units Backward Q -
K/A SRO Only 91 H
1 N
E Part 2 of stem (was) cues that there is only one TS required component inop, therefore C and D are implausible.
Added were to part 2 of stem.
92 H
2 B
S 93 H
2 B
S 94 F
2 N
E Changed warehouse workers to equipment operator in stem 95 F
3 N
E Removed first sentence in stem Removed capitalized audits in stem 96 H
3 N
S 97 F
2 N
S 98 F
3 N
S 99 F
2 N
S 100 F
3 N
E Removed first sentence in stem