Text
.
e
'i CLASSIFICATION EMERGENCY PROCEDURE A-04, REV. 3 Issue Date: 05/29/98 1.0 ' PURPOSE This procedure provides guidance for the categorization of an emergency situation as a
LOCAL
RESPONSE
- EVENT, ALERT Emergency or SITE AREA Emergency.
2.0 POLICY AND SCOPE To assure consistent and expedient action in the categorization, classification and resolution of emergency situations.
3.O REFERENCES 3.1-Replaces Emergency Procedure A-04, Rev. 2 3.2 EMERGENCY TELEPHONE DIRECTORY, Columbia Site 3.3 SITE EMERGENCY PLAN & PROCEDURES MANUAL 3.4 REGULATORY PROCEDURES 3.5 Hazardous Material Emergency Response and Best Management
.g Practices Plan (BMP)
\\
3.6 10CFR20.2202, 10CFR70.22, 10CFR70.23 3.7 Regulatory Guide 3.67 3.8 Information Notice 93.60 3.9 NRC Form 361A,
" FUEL CYCLE & MATERIALS EVENT NOTIFICATION WORKSHEET" 3.10 NRC Region II Form, " PROTECTIVE MEASURES STATUS" 4.0 TERMS AND DEFINITIONS:
NONE 1
5.0 -REGULATORY REQUIREMENTS This entire procedure is of regulatory significance.
i i
j 6.0 RESPONSIBILITIES 6.1 ACTIONS As necessary, the Emergency Coordinator will assess accident situations to determine response actions and will collaborate with the Emergency Director to determine the need (if any) i for event classification.
[. ()
Page 1 of 9 l
~~
9901260194 590118 PDR ADOCK 07001151 Q%blG C
PIMt _
-. - --.. - -. _ ~. ~ _ - -.- -
1 CLASSIFICATION EMERGENCY PROCEDURE A-04, Rev. 3, 05/29/98 7.O PROCEDURE i
7.1 The Emergency Coordinator will evaluate conditions to determine actions to be taken.
7.2 If an emergency event is declared, the Security Guard will i
make announcements detailing conditions as directed by the l
Emergency Coordinator.
7.3 The Site Emergency Response Organization will assume standby status and act on instructions from the Emergency Coordinator.
i 7.4 Evacuation of the plant (partial or complete) will be per instructions of the Emergency Coordinator.
7.5 The Emergency Coordinator will decide on classification of an event (or not) based on the guidelines in sections 7.11, 7.12 and 7.13.
7.6 When an event is classified an ALERT or SITE AREA emergency:
SC-DHEC, Nuclear Emergency Planning Section, must be notified within 15 minutes of classification; i
Richland County Department of Emergency Services must be notified immediately after SC-DHEC is notified; US-NRC must be notified immediately after the state and county are notified, and in any case within one hour of event classification.
7.7 An event should be reclascified if parameters noted in
'I I
sections 7.11, 7.12 or 7.13 should improve or deteriorate.
7.8 ALERT and SITE AREA emergencies require that the Emergency Director and Emergency Staff convene in the Emergency Operations Center (EOC) for resolution of the situation.
7.9 If an ALERT or SITE AREA emergency occurs on back shift or during non-routine working hours, manning the EOC may not be practical as the Emergency Director and Coordinator may be one in the same.
7.10 Various outside organizations (Fire Department, Sheriff, EMS, DOT, et.al.) may be called to render assistance regardless of the event category.
Page 2 of 9
l CLASSIFICATION I
EMERGENCY PROCEDURE A-04, Rev. 3, 05/29/98 7.11 LOCAL RESPONSE EVENT (non-classified event)
Any accident or minor emergency situation causing deviation from nonnal operations which can be managed within the confines of the plant and/or site.
CONTROL of the situation can be achieved in <15 minutes (<24 hours for powder / liquid spill);
no threat to the environment; no off-site release, consequence or response; partial or total mobilization of the Emergency Response Organization (ERO).
Examples:
CASUALTY TRANSFER (contaminated)
CIVIL DISORDER COMMUNICATION System Loss
]
(.
CRITICALITY: controlled deterioration of nuclear criticality t.
safety barriers FIRE which does not and will not affect radioactive material, hazardous material (s) or safety systems POP: combustible gas pop, no threat to environment POWER / WATER LOSS RELEASE (controlled) of UF6 gas, toxic gas or hazardous material (s) where the source of release can be isolated, the source confined and no threat of further escalation RUPTURE of containment vessel or line SPILL of powder / liquid (radioactive, toxic or hazardous) which can be cleaned up in less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> VENTILATION FAILURE with no threat of release to environment WEATHER: hazardous weather warning io Page 3 of 9
l 9
CLASSIFICATION h('7 EMERGENCY PROCEDURE A-04, Rev. 3, 05/29/98 i
7.12 ALERT ExERGENCY (classified event) radioactive material, hazardous material (s) or safety systems might be affected; the situation CANNOT BE CONTROTJan in <15 minutes (<24 hours for powder / liquid spills);
threat of further escalation; possible impact on environment, off-site release actual or-possible, but no response required of off-site organizations to protect off-site personnel; partial or total mobilization of ERO required.
Examples:
AIRCRAFT CRASH into facility BOMB THREAT CIVIL DISORDER (security intrusion >15 minutes)
CRITICALITY:
uncontrolled deterioration of nuclear
("]
()
criticality safety barriers EXPLOSION which may have an effect on the. environment FIRE which might affect radioactive
- material, hazardous material (s) or safety systems I
RELEASE (uncontrolled) of UF6 gas, toxic gas or hazardous material (s) where the source of release cannot be isolated nor the source confined, and there is a threat of further escalation SPILL of powder / liquid (radioactive, toxic or hazardous) which cannot be cleaned up in less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> VENTILATION FAILURE which may impact the environment j
I UPGRADES from LOCAL RESPONSE category WEATHER: earthquake, flood, hurricane, hurricane force winds or tornado j
i
. )
Pags 4 of 9
. -.. - ~
Ih CLASSIFICATION EMERGENCY PROCEDURE A-04, Rev. 3, 05/29/98 7.13 SITE AREA ExERGENCY (classified event) radioactive material, hazardous material (s) or safety systems have been affected; OUT OF CONTROL situation, timely resolution not expected; radioactive, toxic or hazardous material threat to offsite environment or member (s) of the general public; response required of off-site organizations to protect the environment or persons off-site; precautionary notification or evacuation of members of the public; actual or imminent loss of physical control of the facility; total mobilization of ERO.
Examples:
CIVIL DISORDER causing imminent or actual loss of physical control of the facility CRITICALITY: confirmed O
,(j EXPLOSION involving off-site threat or loss of physical control of the far ~lity FIRE involving off-site threat or loss of physical control of the facility RELEASE of UF6
- gas, toxic gas or hazardous material (s) involving off-site threat or loss of physical control of the facility SPILL of powder / liquid (radioactive, toxic or hazardous) involving off-site threat or loss of physical control of the facility VENTILATION FAILURE concurrent with loss of containment and major SNM release WEATHER: earthquake, flood, hurricane, hurricane force winds or tornado which physically strike and/or impact the facility 8.0 CLASSIFICATION LOGIC FLOW CHARTS l
Pages 6, 7,
8&9 l
Page 5 of 9
. _. l CLASSIFICATION LOGIC FLOW CHART Emergency Procedure A44, Rev. 3,05/29/98 Criticality Accident, UF6 Release, Fire
.m l
Event iniheems l
)
Cowened Dessnareten er Nuesar Cnhably Edely semers No Aandantal Crenstly
.)
S l
i Uncanented Deannarsson of y,,
Nuoteer Crammaly Bassey No T
ammers E
R n.e.
ye, To Onseo Eremenmere or a
Mammer et v. Peac M
Co,,,,,,
a=' " 'a ' 5 -
A E
L j
(Assrostk.s woo Coened, No o
a O
No n ust w Fwther
{
M Escaissan C
E Ossee Reaper.o Roosed No y,,
p.
A R
*" '""'na's"e'"'
C Persons O e
L T
M j
Un,.,,,,,,
Cen1 De tenenned Wthin 15 Ves y,
termans (Appn.1 Sawco N C
- d. n== w F-a -
G E
E_., u rs w v.
N C
Fro Wum Cai to Y
Yes Emnguened h Less The 15 N.
uramme (Approm.) and No n== =,. En.oron-.
j n nr.ni or Aaum toes e v.,
No Pnysom C w a l
Fechty Fro Wum Care to i
EJerqNuned m Lane The 15 Ye8 No Mrsans (Agipram.) and Threat er Fwther Eaussmann i
l 3,
ir 1r 1r l'
l implement Corrective / Remedial Actions 1,
T O.
\\
Ratwn To Nonnel l
esso e or e
i +
CLASSFICATION LOGIC FLOW CHART Emergency Procedure A44, Rev. 3,05/29/98 1
Powder / Liquid Spill, Ventilation Problem, Explosion t
Powdertamed Epis Whom j
Yes Cm be C4emed Neun N Howe (Approm) and No Ttreet To Erwronmaru I
Rochoedwo MosenW 7 tron No To O.nese E,nwonment or M.
- p.
- S Powder & head Spa Whnm Cerft Be Cleaned Whn N Vee No T
News (Approm ) and l
Ttweetens The Erwronmart E
Onnes Respoies Rooned y,,
To Protect Erwrerynert er A
-~
R v~ ~
E L
^
ve, (No fivest of Ratesse To M
No O
L A
C E
E_, Merr,. " '"
E A
R
=
L T
M
,~
Veniseman Fakse Whum May Y/
Have M Imped On The No Erwronmers G
.r.r
- r..r =
- E v.
Physcal Can.W at the N
rear C
,os Co,.m.N one w u
Where There N No Ttwest Of No I
Re. nee To The Erwrorvnert No Espioman Whum May Have y,,
M impact On The Erwronmers No q,
ir ir 1r 1r implement Corrective / Remedial Actions l
l
[
1r l f\\lV
- To Normai Page 7 at 9
I~
CLASSIFICATION LOGIC FLOW CHART l
Emergency Procedure A44, Rev. 3,05f29198 l e Hazardous Weather, Civil Disorder, Contaminated Casualty I
![
l Event inhetes l
\\
4
\\
\\m/
>w w =e.r Va.
j!srgg;
)
(Tomado. tesnumis. Flood, i
M l
Redma.ceve Ideeenel Threat y,,
94o To O.me Emerimers or m== e pume g
l
.= __
P, r
v.
Mhch Thressen.
T
,'a Envuonmore O
as e as e.
,s.
To Pnned Envvenment er
\\
m o T,.e.
A E
L O
L A
C E
e-,-
v" E
A R
euni=.
L T
M A
E lJ TJo"e.""
R G
.nen,.,e., - u.
E v
w cor.w a v.
r-v N
C Y
v
ui e -
o l
\\
vu cornemr a cam.nr i
Trun.6er to Ho.p el I
l l
ir 5,
1,
ir Implement Corrective / Remedial Actions l
l ie i
Roun To Dearmel i
Operspan.
Page 8 of 9
CLASSIFICATION LOGIC FLOW CHART Em:rgency Procedure A44, Rev. 3,05/29/98 l e Hazardous Material Release / Spill, Power Loss, Rupture, Bomb Threat l
l l
Event initetes l
1 J Conirobed Hasensous Man.isl h*
Yee leolated Wehm 15 Mnutes (approth Some Cardnad No Thuit W Fwgier
)
Eeceleken I
h Messnel Tweet y,e 88 o To Onese E.rwrunm.ent or Me, e S
uno oind l
N=. deus Meien.
Corn Be lealeted wishn No 15 Mrmese tapprom L.Sauros Not Cadnad Two 8 r-urgier E G
Onsee Respunes Roosed y
To Protect Enemmert er A
- oas.
R L
A E
o e.e-or - s.,
O L
A C
E A
R L"'"*"' " "
E L
T M
l E
(
Co e.irne,. vanaw No o
or tria n
G E
---a v-en,-w c m =
"r N
C Y
.o, Two.
No l
implement Corrective / Remedial Actions u
- To Page 9,9
,