Text

4 4

BIC ROCK POINT SEMI ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT (Revised)

JULY - DECEMBER 1981 This report provides information relating to the radioactive effluent releases and solid radioactive waste disposal operations of Big Rock Point during the period of July - December 1987. Format for this report is contained in Technical Specification 6.9.2.2.

Big Rock was on-line for most of this reporting period with the exceptions of the following "mini-outage" datest July 24-268 September 6-10, November 9-14, November 21-23 and December 2-7.

Reasons for the maintenance outages were due to minor steam leaks.

1.

Supplemental Information A.

Batch Releases Information relating to continuous and batch releases of gaseous and liquid effluents is provided in Table HP 10.3-1.

B.

Abnormal Releases None.

2.

Caseous Effluents Table HP 10.3-2 lists and summarizes s11 gaseous radioactive effluents released during the reporting period. The unidentified beta was y

3.45E-06% of the total release. The maximum noble gas release rate for the third and fourth quarters was 3.69E+02 and 3.65E+02 pCl/second, respectively.

3.

Liquid Effluents Table HP 10.3-3 lists and summarizes all liquid radioactive effluents released during the reporting period. The unidentified beta was 15.7%

of the total release.

The maximum liquid ef fluent release concen-tration for the third and fourth quarters was 1.36E-06 and 1.14E-07 pCi/al, respectively.

4.

Solid Waste Solid radwaste classification, sources, volume shipped, curie and nuclide content are detailed in Table HP 10.3-4.

The one radwaste shipment was sent to Richland, Washington for burial.

8909140347 080031

~

POR ADOCK 05000155 R

PDR IC0888-0172A-HP01 12 L

TABLE HP 10.3-2 BIC ROCK POINT SEMI ANNUAL RADI0 ACTIVE EFFLUENT RELEASE REPORT (Revised) i i

CASEQUS EFFLUENTS - SUMMATION OF RELEASES JULY 1987 to DECEMBER 1987 Est Total A.

FISSION AND ACTIVATION CASES UMITS 3rd QUARTER 4th QUARTER Error 1 1.

Total release Ci 2.99E+03 2.33E+03 2.

Averste release rate for period uCi/see 3.76E+02 2.93E+02 4.91 3.

Percent of annual ava MPC 1.04E-01 8.11E-02 B.

IODINES 1.

Total Todine ci 6.79E-03 8.07E-03 2.

Aversae release rate for period uct/sec 8.54E-04 1.02E-03 5.51*

3.

Percent of annual ava MPC 1

2.63E-05 2.68E-05 C.

P ARTI CU LATE S 1.

Particulates with half-life >

8 days Cl 9.17E-04 7.34E*04 2.

Averste release rate for period uCi/see 1.1SE-04 9.86E-05 3.

Percent of annual avn MPC 1

7.46E-06 2.31E-06 10.8 1

4 Cross alpha radioactivity Ci E.30E-07 8.50E-07 5.

Cross alpha release rate for period uCl/see 1.04E-07 1.07E-07 D.

TRITIUM 1.

Total release ci 1.3E+00 1.3E+00 i

2.

Averane release rate for period uCI/see 1.6E-01 1.6E-01 3.

Percent of annual ava MPC 1

7.4 E-06 1.4E-06 I

i "E.

1.

Sesa air dose at site boundary due i

to Noble Cases (TS 13.1.4.2a) mRads 1.83E-02

_1.42E-02 2.

Percent l i mi_ t 1

1483E-01 1.42E-01 3.

Camma cir dose at site boundary due t o No bl e Ca se s ( T S 13.,1.4. 2 a )

mRads 3.05E-02 2.33E-02 4

Peretnt limit t

6.1CE-01 4.66E-01 1.

Maximum organ dose to public based

~~

based on critical receptors l

(TS 13.1.4.34) mrem 1.36E-02 5.77E-03 2.

Percent of lielt t

1.81E-01 7.69E-02

  • Notet Data is reported for I-131 and I-133 only 1

i IC0888-0172A-HP01 13

~

TABLE HP 10.3-2 i

BIC ROCK POINT SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT (Revised)

CASE 00S EFFLUENTS JULY 1987 to DECEMBER 1987 3.

PARTICULATES*

Units I

3rd QUARTER 4th QUARTER l

chromium-51 Cl 4.45E-05 1.43E-04 Manaanese-54 Ci 9.40E-06 1.15E-05 Cobalt-58 Cl Wone None Cobalt-60 Ci 2.70E-05 4.20E-05 Zine-65 C1 1.30E-06 1.00E-05 j

Barlum-140 CI 4.44 E-04 2.360-04 r

Cesium-134 Ci 3.55E-05 6.69E-05 Ceslum-137 CI 9.70E-05

)

1.56E-04 3

Wiobium-95 Ci None 2.87E-07 S11ver-110m Cl 1.30E-06 1.2SE-05 l

i S t r on t i um-91*

  • Ci 6.60E-03 3.69E-03 i

Lanthanum-140**

Cl 1.33E-03 7.10E-04 Bremine-82**

Ci 5.43E-03 3.11E-03 5odlum-24**

Ci No,ne 2.52E-05 M ol ybde num-99 **

Ci 6.50E-06 3.14E-05 i

Westunium-239**

Ci None 1.85E-05 Strontium-89***

Ci 9.6E-05 8.1E-05 i

St~ontlum-90***

Cl 1.1E-06 1.3E-06 i

Net unidentified beta ci 1.60E-04 2.37E-05 i

t Total Ci 9.17E-04 7.84E-04

  • Particulates with half-lives >8 days.

1

    • Particulates with half-lives (8 dayst not reflected in overall isotopic totals.

l

      • Calculated from vendor analysis of monthly stack ass filters. Reported net beta and vendor analyzed Sr-89/90 results were input to CASPAR code as Sr-90 to yield conservative dose estimates.

IC0888-0172A-HP01 14

.~

TABLE HP 10.3-3 (Revised) 4 BIC ROCK POINT SEMI ANNUAL RADI0 ACTIVE EFFLUENT RELEASE REPORT LIQUID EFFLUENTS - SUMHATION OF RELEASES JULY 1987 to DECEMBdR 1987 Est Total A._

FISSION AND ACTIVATION PRODUCTS UNITS 3rd QUARTER 4 t h QU ARTER Error %_

1.

Total release (not including I

tritium, asses, alpha)

Cl 1.00E-01 6.48E-03 2.

Averagt diluted concentration durina period uct/mi 3.89E-09 2.60E-10 4.27 j

3.

Percent of MPC 1

4.49E-01, 4.77E-03 J

B.

TRITIUM j

1..

Total rolese)

Ci 9.52E-02 1.54E-02 l

2.

Average diluted concentration durina period uCl/ml 3.69E-09 6.18E-10 6.16 3

3.

Percent,of MPC 1

1.23E-04 2.06E-05 C.

DISSOLVED AND ENTRAINED CASES 1.

Total Release Ci None None 1

2.

Average diluted concentration durina period uCi/ml None None None 3.

Percent of MPC 1

None None l

I q

D.

GROSS ALPHA RADIOACTIVITY (Total R61 ease)

Ci 2.28E-06 2.00E-07 i

1.

Average diluted concentration during period uCl/ml 8.84E-14 8.03E-15 i

l E.

VOLUME OF WASTE PELEASED

-(Prior to Dilution)

Liters 5.11E+04 3.36E+04 I

i F.

VOLUME OF DILUTION WATER USED DURING PERIOD Liters 2.58E+10 2.49E+10 C.

MAXIMUM DOSE COMMITMENT - WHOLEBODY mrem 4.65E-02 7.22E-03 3

Percent of TS 3.24.4.la limit 1

3.10E00 4.81E-01 j

1 1

8 j

H.

M AXIM UM DOS E COMM ITMENT - ORG AN mrem 1.00E-01 1.15E-02 j

Percent of TS 3.24.4.la limit 1

2.00E00 2.30E-01 4

i 1

1 4

i IC0888-0172A-HP01 15 l

TABLE HP 10.3-3 (Revised)

B!C ROCK POINT SEMIANNUAL RADI0 ACTIVE EFFLUENT RELEASE REPORT i

LIQUID EFFLUENTS JULY 1987 to DECEMBER 1987 1.

NUCLIDES RELEASED Units 3rd QUARTER 4th QUARTER I

Cesium-137 Cl 1.27E-02 2.70E-03 Cobalt-58 Ci 7.40E-04 None Manaanese-54 Cl 2.79E-02

1. 00 E-03 Cobalt-60 Ci 2.01E-02 2.10E-03 Cesium-134 Ci 8.80E-04 3.40E-04 Iron-59 C1 2.28E-03 None

[

Chromium-51 Cl 5.00E-04 None Zinc-65 Cl 6.10E-04 hone i

i 511ver-110m Ci 3.30E-04 None l

l Iodine-121 C1 2.00E-05 None i

Strontium-89**

Cl 1.8E-04 2.3E-05 l

Strontium-90**

Ci 2.7E-04 3.5E-05 i

Net Unidentified f

Beta C1 3.39E-02 2.42E-04 l

Fission & Activation i

Product Total (Above)

Ci 1.00E-01 6.48E-03 Xenon-133 Ci None None Tritium Cl 9.52E-02 1.54E-62 Crand Total Cl 1.95E-01 2.19E-02

    • Notel Calculated from vendor analysis of monthly radweste composite samples.

Reported not beta and vendor analysed Sr 89/90 results were input to LADTAP code as Sr-90 to yield conservative dose estimates.

IC0888-0172A-HP01 16

-