ML20138Q580
| ML20138Q580 | |
| Person / Time | |
|---|---|
| Site: | Crystal River |
| Issue date: | 06/21/1985 |
| From: | Alberdi J, Kelly L FLORIDA POWER CORP. |
| To: | |
| Shared Package | |
| ML20138Q563 | List: |
| References | |
| TDP-201, NUDOCS 8512270303 | |
| Download: ML20138Q580 (42) | |
Text
~
(
[
TDP-201 Rev.3 Fk>rida NUCLEAR OPERATIONS TRAINING
.P.o...w..e...r.DEPARTMENT PROCEDURE DATE: 6/21/85 4
g Page 1 of 42 NON-LICENSED OPERATOR vucumum Ju N FO R M ATIO N O N LN 1.0 PURPOSE C. R. Nuclear The purpose of this procedure is to provide instructions for the implementation of the Non-Licensed Operator Training Program.
2.0 SCOPE This procedure shall apply to those persons within the Nuclear Operations Training Department assigned responsibilities for implementing the Non-Licensed Training Program and to those students in the Non-Licensed Training Program.
3.0 REFERENCES
3.1 Florida Power Corporation, Crystal River Unit 3, Final Safety Analysis Report (FSAR) l l3.2 Florida Power Corporation, Crystal River Unit 3, Technical Specifications 3.3 Institute of Nuclear Power Operationc Guideline GPG-04,
" Guidelines for Qualification Programs", March 1981 3.4 American National Standards Institute - ANSI N18.1 -
1971Property "ANSI code" (as page type) with input value "ANSI N18.1 -</br></br>1971" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process., " Selection and Training of Nuclear Power Plant Personnel" 3.5 Operations Section Implementation Manual (OSIM) 3.6 TDP-105, " Lesson Plan Preparation" 3.7 TDP-108, " Training Prcgram Evaluation" 3.8 TDP-109, " Training Records Management" 3.9 OSIM, Enclosure 25 REVIEW / CONCURRENCE
- APPROVAL Departnent Representative Date Dateh NTS/NOTSS l
Wit my.
Au.( } Meca.gnyer
/C &
////g now MSNOTS*7 I
8b i S
b 4/1//ff B512270303 851223 DSN0*
- As applicable PDR ADOCK 05000302 l
V PDR
r Florida NUCLEAR OPERATIONS TRAINING TDP-201 Rev.3
~
%f DEPARTMENT PROCEDURE DATE: s/21/as I
pano 9 ne a9 TITLE:
NON-LICENSED OPERATOR TRAINING PROGRAM 4.0 DEFINITIONS 4.1 ASSISTANT NUCLEAR AUXILIARY OPERATOR The Assistant Nuclear Auxiliary Operator are those persons who operate the support systems equipment on the secondary plant side of the Florida Power Corporation Crystal River Nuclear Plant.
4.2 NUCLEAR AUXILIARY OPERATOR The Nuclear Auxiliary Operators are those persons who operate the secondary plant side equipment of the Florida Power Corporation Crystal River Nuclear Plant.
4.3 ASSISTANT NUCLEAR OPERATOR The Assistant Nuclear Operators are those persons who operate the primary plant side equipment of the Florida Power Corporation Crystal River Nuclear Plant.
I I
5.0 RESPONSIBILITIES 5.1 OPERATIONS SUPERINTENDENT - Responsible for:
ensuring that annual evaluations are performed for all Non-Licensed Operators; review evaluations and recommend any special training as needed.
5.2 NUCLE'R SHIFT SUPERVISOR - Responsible for performing A
the Non-License Annual evaluations.
5.3 NUCLEAR OPERATIONS TRAINING SUPERVISOR (NOTS)
Responsible for the overall implementation and administration of the Non-Licensed Operator Training Program. The NOTS is also responsible for approving all Lesson Plans and for developing lesson plans that will provide feedback of operating experience to the students.
5.4 NON-LICENSED OPERATOR STUDENT
- Responsible for satisfactorily completing the Non-Licensed Operator Training Program.
I I
r m -2ol Rev.3 Florida NUCLEAR OPERATIONS TRAINING Mf DEPARTMENT PROCEDURE DATE: 6/21/85 4
Page 3 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM 6.0 ACTION
6.1 INTRODUCTION
6.1.1 The goal of the Non-Licensed Operator Training Program is to ensure that the Assistant Nuclear Auxiliary Operators, Nuclear Auxiliary Operators, and Assistant Nuclear Operators have the necessary knowledge and skills to operate the associated equipment of the Nuclear plant in a safe and competent manner.
6.1.2 The Non-Licensed Operator Training Program shall consist of three separate phases. These phases are:
1.
Assistant Nuclear Auxiliary Operator - ANAO 2.
Nuclear Auxiliary Operator
- NAO 3.
Assistant Nuclear Operator
- ANO 6.1.3 For each subject of course instruction in this program, an estimated time is stated as an indication of the
{
l instructional time required to achieve the desired depth of understanding.
6.2 TRAINING PROGRAM STRUCTURE 6.2.1 Classroom Training Classroom training will be the first part given for each " phase of the Non-Licensed Operator Training Program.
6.2.2 On-Shift Training Upon completion of classroom training associated with a phase of the Non-Licensed Operator Training Program the individual will be assigned on shift.
6.2.2.1 During on-shift training the Non-Licensed Operator candidate will complete the appropriate Qualification Manual for the classroom phase he has just completed.
I l
r Florida NUCLEAR OPERATIONS TRAINING TDP-2ol Rev.3 J
DEPARTMENT PROCEDURE DATE: 6/21/8s Pano a nf d?
TITLE:
NON-LICENSED OPERATOR TRAINING PROGRAM 6.2.2.2 The Qualification Manuals for the Non-Licensed Operator are as follows:
1.
Assistant Nuclear Auxiliary Operator Qualification Manual 2.
Nuclear Auxiliary Operator Qualification Manual 3.
Assistant Nuclear Operator Qualification Checklist (Enclosure 17 of the OSIM) 6.2.2.3 Prior to entering the next phase of Non-Licensed Operator Training, the student must have the previous courses, and Qualification Manual / List completed.
6.2.3 Training Cycle 6.2.3.1 The steps to complete the Non-Licensed Operator Training Program shall be in the following order:
1.
ANAO - Classroom Training 2.
ANAO - On-Shift Training l
l 3.
NAO
- Classroom Training 4.
NAO
- On-Shift Training 5.
- Classroom Training 6.
- On-Shift Training 6.2.3.2 Authorization to alter or exempt part or all of the Non-Licensed Operator Training Program cycle steps must be obtained from the Nuclear Operations Training Super' visor.
6.3 PROGRAM CONTENT i.
6.3.1 Assistant Nuclear Auxiliary Operator Program (ANAO)
The ANAO classroom program summary depicting
- Topics, contact Hours and Lesson Plan Numbers is listed on of this procedure.
l l
t i
l l
l t
I
c T P-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING P. o...w.. e...f.'DEPARTMENT PROCEDURE DATE: 6/21/85 4
Page 5 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM 6.3.2 Nuclear Auxiliary Operator Program (NAO)
The NAO classroom program summary depicting Topics, Contact Hours and Lesson Plan Numbers is listed on of this procedure.
6.3.3 Assistant Nuclear Operator Program (ANO)
The ANO classroom program summary depicting Topics, Contact Hours and Lesson Plan Numbers is listed on of this procedure.
6.3.4 Special Training Program 6.3.4.1 The purpose of this program is to provide update information to Non-Licensed Operators.
6.3.4.2 Update information may include, but is not limited to, the following:
l I
a.
Applicable Procedure Changes b.
Plant Modifications c.
Licensee Event Reports d.
Industry Operating Experiences 6.4 STUDENT EVALUATION The purpose of the student evaluation is to ensure that the Non-Licensed Operator has acquired sufficient knowledge and skills to properly perform assigned tasks.
6.4.1 Written Examinations 6.4.1.1 Satisfactory completion of a written examination is met when the student attains, at a minimum, a score of 70%
for each individual category with an overall examination average of 80%.
l
Florida NUCLEAR OPERATIONS TRAINING TDP-201 Rev.3 DEPARTMENT PROCEDURE DATE: 6/21/85 vnna a me a, TITLE:
NON-LICENSED OPERATOR TRAINING PROGRAM 6.4.1.2 Advancement to the next phase or final completion of the Non-Licensed Operator Training Program requires that the student have final program phase averages of 70% in each category, and 80% overall.
6.4.2 Oral Examinations 6.4.2.1 Oral examinations will be administered to evaluate a
student's academic progress and ability to explain information verbally.
6.4.2.2 The grading scale for Oral Examinations will be as follows:
90 - 100 Excellent - answers are
- accurate, concise, complete.
80 - 89 Good - answers are
- accurate, partially complete.
70 - 79 Fair - answers are
- accurate, partially complete, needed some prompting.
{
l 0 - 69 Unsatisfactory - answers inaccurate, unable to
- answer, or answered only after much prompting.
6.4.2.3 Satisfactory completion of an oral examination is met when the student attains, at a minimum, a score o.*
70%
for each individual category with an overall examination average of 80%.
6.4.3 Remedial Training The Nuclear Non-Licensed Operator Training Supervisor shall determine any Remedial Training to be performed in the event of unsatisfactory student progress.
s
Florida NUCLEAR OPERATIONS TRAINING TDP-201 Rev.3 f
DEPARTMENT PROCEDURE DATE: 6/21/85 k
vnno, me to TITLE:
'.40N-LICENSED OPERATOR TRAINING PROGRAM 6.5 KEQUALIFICATION 6.5.1 All Non-Licensed Operators must attend the portions of the Licensed Operator requalification classroom sessions that app,1y to their job position.
These portions will be determined by the NOTS or his designee according to each non-licensed job skill matrix and noted on the Licensed Operator requalification schedule.
As a minimum, Non-Licensed Operators will participate in on-shift lectures that cover the following topics as they pcrtain to the Non-Licensed Operator positions:
o normal operating procedures o
abnormal operating procedures o
emergency operating procedures Note:
The above discussions will include operational limitations, precautions and set
{
points.
o emergency plan o
security procedures o
changes in plant design and operating procedures Additionally, the Non-Lic nsed Operators must attend pre-planned lectures on e gency shutdown systems and alarm and instrumentation systems and signals as part of the Licensed Operator Requalification Program as they pertain to the Non-Licensed Operator positions.
The Non-Licensed Operator will receive retraining on general safety, first aid, and radiation safety as part of General Employee Retraining.
6.5.2 All ANO's and any other Non-Licensed operators performing as stepped up ANO's shall have biannual retraining in the Operation of Radioactive Waste Systems.
I
T P-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING f
DEPARTMENT PROCEDURE DATE: 6/21/85 4
Paqo 8 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM 6.5.3 In addition, special training will be provided to the Non-Licensed Operators in areas identified by the NOTS or his designeo.
Section 6.3.4 provides guidance for special training topics.
6.5.4 The Non-Licensed Operators will be evaluated annually in the performance of assigned duties including operation of selected auxiliary systems important to overall plant safety.
The Nuclear Shift Supervisor or the Assistant Nuclear Shift Supervisor will perform this ovaluation using Enclosure 25 of the OSIM.
The Nuclear Shift Supervisor will forward the completed OSIM Enclosure 25 to the Operations Superintendent. The Operations Superintendent will review the evaluations and recommend any special training as
- needed, and date/ sign the evaluation and forward it to the NOTS with the recommendations.
6.6 LESSON PLANS I
I
.6.1 All Lesson Plans used and material developed must be 6
completed in accordance with TDP-105,
" Lesson Plan Preparation". Exemptions to this policy will be allowed for vendor supplied training.
6.6.2 The NOTS is responsible for approving all Lesson Plans and for developing lesson plans that will provide feedback of operating experience to the students.
6.7 PROGRAM EVALUATirN 6.7.1 The Non-Licensed Operator Training Program will be evaluated in accordance with TDP-108, " Training Program Evaluation".
6.8 EXAMINATION PREPARATION 6.8.1 All examinations must be prepared, administered and graded in accordance with procedure TDP-10G,
" Examination Preparation, Administration and Evaluation".
I l
c P-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING DEPARTMENT PROCEDURE DATE: 6/21/85 4
Page 9 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM 6.9 INSTRUCTOR QUALIFICATION 6.9.1 The Instructors who teach or otherwise conduct training for this program must meet the requirements of TDP-111, " Instructor Development Program".
7.0 ATTACHMENTS A17D APPENDICES 7.1 Appendix A-Assistant Nuclear Auxiliary Operator Program Description 7.2 Appendix B Nuclear Auxiliary Operator Program Description Assistant Nuclear Operator Program 7.3 Appendix C Description 8.0 QUALITY RECORDS,
8.1 The following records are quality records and shall I
be maintained in accordanco with TDP-109
" Training Program Documentation".
8.1.1 Non-Licensed Operator Training Program description for each class.
8.1.2 Non-Licensed Operator Training Program schedule for each class.
8.1.3 Each Lesson Plan used.
8.1.4 Class attendance list. This record must also show who the Instructor is for each lesson.
8.1.5 Copy of each examination with answer key.
8.1.6 Class examination summary (TDP-106 Attachment 4).
9
, ~. -
Florida NUCLEAR OPERATIONS TRAINING TDP-201 Rev.3 M
DEPARTMENT PROCEDURE DATE: 6/21/85 pnno in nr 49 TITLE NON-LICENSED OPERATOR TRAINING PROGRAM 8.2 The following individual student records shall be kept as part of each student's file.
8.2.1 Each written examination and corresponding answers.
8.2.2 The results of each oral examination.
8.2.3 Any remedial training program description and results.
8.2.4 Any training program waivers.
8.2.5 Completed qualification manuals.
9.0 INTERPRETATION CONTACT Nuclear Operations Training Supervisor 10.0 REVISION HISTORY
{
l Revision 0 Date: 10/01/81 Original Release Revision 1 Date: 09/15/83 Complete Revision Revision 2 Date: 01/10/85 Partial Revision Revision 3 Date: 06/21/85 Complete Revision 11.0 REVIEN HISTORY Date Person Conducting Review Comments l
I s
TDP-2ol Rev.3 Florida NUCLEAR OPERATIONS TRAINING DEPARTMENT PROCEDURE DATE: 6/21/85 Page 11 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 1 Assictant Nuclear Auxiliary Operator Program CONTACT IIOURS LESSON NUMBER TOPIC 2
ANAO-1 Accident Provention Manual 12 ANAO-2 First Aid 8
ANAO-3 Cardiopulmonary Ronuncitation 4
ANAO-4 Administration Introduction Emergency Plan OSIM POQAM STS-ETS Logkooping Good !!ounokooping 8
ANAO-5 Prints Flow Diagrama Print Readings MARS Aporturo Card / Microfilm Index ANAO-6 Doloted 8
ANAO-7 Valvos
==
Introduction:==
Purpono Typen Applications i
i
TDP-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING DEPARTMENT PROCEDURE DATE: 6/21/85 Paco 12 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 1 (Continued)
Assistant Nuclear Auxiliary Operator Program CONTACT HOURS LESSON NUMBER TOPIC 4
ANAO-8 Pumpo
==
Introduction:==
Purpose Types Applications 2
ANAO-9 Traps, Strainoro,and Filtorn 12 ANAO-10 HTFF
==
Introduction:==
Enorgy conversion Proportion and l
Fluid Flow Prosauro Tomparaturo and Hoat 2
ANAO-ll Mausuring Dovicon
==
Introduction:==
Tomparaturo Pronouro Flow Lovel l
Fkwida NUCLEAR OPERATIONS TRAINING TDP-2ol Rev.3 DEPARTMENT PROCEDURE L' ATE : 6/21/85 I
ran.
1, ne n TITLE NON-LICENSED OPERATOR TRAINI!TG PROGRAM ATTACHMENT 1 (Continued)
Assistant Nuclear Auxiliary Operator Progr g CONTACT HOURS LESSON NUMBER TOPIC 4
ANAO-12 Primary Systems Introductions Reactor Coolant Makeup and Purification Nuclear Services Cooling Decay Hoat Removal Decay Heat Closed Cycle Cooling
{
l Docay Hoat and Nuclear Sorvices Raw Water Core Flood Spont Fuol Cooling 4
ANAO-13 Secondary Systems Introduction Main Steam Auxiliary Steam Rohoat and Extraction Steam Main Turbino Main Condonsor condannato Foodwater Emorgency Foodwater Circulating Water Secondary Servicos Cooling l
l
Florida NUCLEAR OPERATIONS TRAINING TOP-201 Rev.3
~
DEPARTMENT PROCEDURE DATE: 6/21/8s I
n,no la ne ao TITLEi NON-LICENSED OPERATOR TRAINING PROGRAM 1.rTACHMENT 1 (Ccntinued)
Annistant Nuclear Auxiliary Operator Program CONTACT HOURS LESSON NUMBER TOPIC 4
ANAO-14 Electrical Distribution
==
Introduction:==
Switchyard 6,900 Volt Switchgoar 4,160 Volt Switchgoar 400 Volt Switchgoar Emergency Dional Generator 2
ANAO-15 Chemintry
==
Introduction:==
Atomic Structuro Periodic Table Water Purity and Quality
{
}
Water Softoning 2
ANAO-16 Chemistry
==
Introduction:==
Ion Exchange Neutralization 2
ANAO-17 Chemintry
==
Introduction:==
Danorating Diotilling 2
ANAO-18 Radiation Protection
==
Introduction:==
Typen Biological Effects Limito l
l 1
P-2ol Rw.3 Florida NUCLEAR OPERATIONS TRAINING DEPARTMENT PROCEDURE DATE: 6/21/85 4
Page 15 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACNMENT 1 (Continued)
Annistant Nuclear Auxiliary Operator Program CONTACT NOURS LESSON NUMBER T_0PIC 2
ANAO-19 Nuclear Plant Nuclear Energy 2
ANAO-20 Nuclear Plant The Nuclear Power Plant 2
ANAO-21 Nuclear Plant Nuclear Power Plant Construction and Liconning I
I 2
ANAO-22 Nuclear Plant Nuclear Power Plant Operations 2
ANAO-23 Nuclear Plant Cyntal River Nuclear Plant Orientation and Layout 2
ANAO-24 Plant Communication System 4
ANAO-25 Scroon Wanh Syntom 4
ANAO-26 Domontic Wator Syntom 2
ANAO-27 Dominoralized Water Syntom 4
ANAO-20 circulating Water Syntom l
l
TDP-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING DEPARTMENT PROCEDURE DATE: 6/21/85 Pago 16 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 1 (Continued)
Assistant Nuclear Auxiliary Operator Program CONTACT HOURS LESSON NUMBER TOPIC 2
ANAO-29 Wator Box Priming System ANAO-30 Deleted 2
ANAO-31 Main Condonsor Air Removal System 4
ANAO-32 Secondary Services closed cycle Cooling System 2
ANAO-33 Secondary Chemical Sampling and Addition System 2
ANAO-34
==
Introduction:==
Condensato and Main l
l Foodwater Systemn 4
ANAO-35 Station Air and Instrument Air System 4
ANAO-36 Ventilation Systems Turbine Building Firo Pump House NaOH Tank Area Office Building 2
ANAO-37 CO2-N2-H2 Storago System 2
ANAO-30 Turbine Building and out Building Drains and Sumps 8
ANAO-39 Fire Protection and Detection System
TDP-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING M
DEPARTMENT PROCEDURE DATE: 6/21/85 Paco 17 of 42 TITLE:
NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 1 (Continued)
Assistant Nuclear Auxiliary Operator Program CONTACT HOURS LESSON NUMBER TOPIC 2
ANAO-40 Emergency Support Facilition Technical Support Cantor Emergency Operations Facility Corporate Command Contor 2
ANAO-41 Motocrological Tower Syntom 2
ANAO-42 011 Water Separator and Puriflor Systemn 4
ANAO-43 SP-300/301 l
TDP-201 Rw.3 Florida NUCLEAR OPERATIONS TRAINING DEPARTMENT PROCEDURE DATE: 6/21/85 y
Page la of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 2 Nuclear Auxiliary Operator Program CONTACT ljoURS LESSON NUMBER TOPIC NAO-1 Deleted NAO-2 Deleted 2
NAO-3 Math Whole Numborn Fractions 2
NAO-4 Math Decimals Porcentagos l
I Arithmatic Operationn 2
NAO-5 Math Exponents Powers Radicals 2
NAO-6 Math Scientific Notation 2
NAO-7&
Math NAO-O Logarithmo l
I
TDP-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING DJ DEPARTMENT PROCEDURE DATE: 6/21/85 l
)
Paco 19 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 2 (Continued)
Nuclear Auxiliary Operator Program CONTACT HOURS LESSON NUMBER TOPIC 2
NAO-9 Math Algebraic Operations I 2
NAO-10 Math Algebraic Operations II 2
NAO-11 Matl1 Algebraic Problems 2
NAO-12 Math l
I Syntoms of Equations 2
!!AO-13 Math Quadratic Equationo 2
NAO-14 Math Exponential Equations 2
NAO-15 Math Applications of Equations to Phynical Syntoma 2
NAO-16 Math Graphing l
I
TDP-2ol Rn.3 Florida NUCLEAR OPERATIONS TRAINING M
DEPARTMENT PROCEDURE DATE: 6/21/85 4
Page 20 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 2 (Continued)
Nuclear Auxiliary Operator Program CONTACT HOURS LESSON NUMBER TOPIC 2
NAO-17 Math Goometry 2
NAO-18 Math Trigonomotry 2
NAO-19&
Math 2
NAO-20 Derivativen and Differentials 2
NAO-21 Math Integrals and Summations 2
NAO-22 Chemistry Atoms and Electrons Danio Model Bohr's Modol 2
NAO-23 Chemistry Electron Dintribution Typon of Bondo 9
Top-2ol Rev.3 Florida NUCLEAR OPERATIONS TRAINING
,M DEPARTMENT PROCEDURE DATE: 6/21/85 Dann 91 nr 49 TITLE:
lion-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 2 (Continued)
Nuclear Auxiliary operator Program CONTACT !!OURS LESSON NUMBER TOPIC 2
NAO-24 Chemintry State of Mattor Roactionn 2
NAO-25 Chemintry Periodic Tablo 2
NAO-26 Chemintry Acido Danon l
l pli 2
NAO-27 Chemintry Purpoco of Water Chomintry Controln Chomicals Centrola 2
NAO-20 Chemintry Effects of Impurition Types of Corronion 2
NAO-29 Chemintry Analysis p!!
Conductivity Ronistivity Total Dianolved Solido l
I
m -201 Rov.3 Florida NUCLEAR OPERATIONS TRAINING DEPARTMENT PROCEDURE DATE: 6/21/85 Parfo 22 of 42
!!ON-LICEllSED OPERATOR TRAINING PROGRM4 ATTACllMEllT 2 (Continued)
Nuclear Auxiliary Operator Progran CONTACT IIOURS LESSoli NUMBER TOPIC 2
NAO-30 Chemistry Analysin:
Chloridon Fluoridon Silica 2
NAO-31 chemistry OTSG Chemistry Limita 0
NAO-32 Valvon l
I Typon components oporatorn Charactorintico 2
!!AO-3 3 Turbinon Introduction Typen Applicationn 2
NAO-34 Turbinon Nozzlan/Diadon Rotorn/ Caning 2
NAU-35 Turbinon Ratoau Curtins l
m -201 Rev.3 NUCLEAR OPERATIONS TRAINING DEPARTMENT PROCEDURE DATE G/21/85 Pago 23 of 42
!!O!!-LICEllSED OPERATOR TRAIllIliG PROGRAM ATTACIIMEllT 2 (Continued)
!!ucionr Auxiliary Operator Program ColiTACT llOURS LESSOli ITUMBER TOPIC 2
!!AO-37 Turbinen l
Compounding P - V Steam Flown 2
flAO-30 Turbinns Turbine Safoty llazards 2
liAO-39 Pumpn Purpone Typos I
Applicationn 2
IIAO-40 Pumpn Contrifugal Pumpo 2
IIAO-41 Pumpo Ponitive Dinplacomont Pumpo 2
IIAO-42 Pumpn Rotary Pumpo I
Top-2ol Rev.3 NUCLEAR OPERATIONS TRAINING DEPARTMENT PROCEDURE DATE: 6/21/85 Parro 24 of 42 NO!!-LICEllSED OPERATOR TRAIllING PROGRAM ATTACl!MEllT 2 (Continued) lluclear Auxiliary Operator Program CollTACT !!OURS LES!!O!! liUMDER TOPIC 4
ffAO-4 3 Comprenners Purpono Types Operation 1.pplicationn 2
liAO-4 4 Lubrication Principles of Lubrication 2
!!AO-45
_ Lubrication l
I Lubricant Charactorintico 2
IIAO-46 Lubrication Additivos, Lubricating Action and Doaring Lubrication 2
IIAO-47 Lubrication Oils and Applicationn 2
ffAO-40 f,ubrication Croacco 2
IfAO-49 J,ubrication Lubricating Compounda l
I
T P-2oi Rev.3 NUCLEAR OPERATIONS TRAINING DEPARTMENT PROCEDURE DATE: 6/21/85 4
Pago 25 of 42 liOff-LICEliNED OPERATOR TRAIllIliG PROGRAM A T T A CIIM E ll T 2, (Continued) lluclear Auxiliary oporator Program CollTACT ll00RS LESS03 It"HDER TOPIC 4
!!AO-50
!!!E The Steam Power Cyclo 4
!!AO-51 IITFF Thormodynamico
!! oat at Work 4
ffAO-52
!!TFF Steam Boilern 4
liAO-53
!!TFF Turbine conorator 4
ITAO-54 flTFF Condonnor 4
IIAO-55 IITFF Pumps and Fluid Flow 4
IIAO-56 IITFF Steam Plant Calculations 4
IIAO-57
!!TFF Roaote,r Thormal and Ilydraulic Performanco O
Floricia NUCLEAR OPERATIONS TRAINING Top-2oI Rev.3 DEPARTMENT PROCEDURE DATE: 6/21/as vann ne nr 1,
TITLE NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 2 (Continued)
Nuclear Auxiliary Operator Program CONTACT HOURS LESSON NUMBER TOPIC 4
NAO-50 HTFF Roactor Fuo) and Coro Danign (PWR) 4 NAO-59 HTFF PWR Performanco 1
NAO-60&
Instrumentation and controln 1
NAO-61 Pressure Sonning Instruments Temperature Sonning Instrumento Lovel Sanning Instrumento
{
}
Flow Sanning Instrumonto 3
NAO-62&
Instrumentation and controln 3
NAO-63 Pneumatic Control Instrumonto Proportional controllern Proportional Plus Intogral Controllars Proportional Plun Integral Plus Renot controllorn 4
NAO-64 Electrical Theory, Introduction conductors and Innulatorn Voltage I
l
T P-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING DEPARTMENT PROCEDURE DATE: 6/21/85 Page 27 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 2 (Continued)
Nuclear Auxiliary Operator! Program
_ CONTACT HOURS LESSON NUMBER TOPIC 4
NAO-65 Electrical Theory Electrical Units OHM'S Law Basic Circuits DC Power 4
NAO-66 Electrical Theory Characteristics of AC and DC Current Current Flow in a Circuit Circuit Types Series and Parallel Circuits l
I Kirchoff's Law Open and Short circuits 4
NAO-67 Electrical Theory Magnets and Magnetism Motion-Flux-Current Induced Voltage Induction Capacitors and Inductors Reactance Impedence Power Factor Power Triangle i
P-2ol Rev.3 Florida NUCLEAR OPERATIONS TRAINING
,%f DEPARTMENT PROCEDURE DATE: 6/21/85 4
l Page 28 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 2 (Continued)
Nuclear Auxiliary Operator Program CONTACT HOURS ESSON IM!BER TOPIC 4
NAO-68 Electrical Theory Three-Phase Systems Wye and Delta Connections Three-Phase Power Transformers Basic Motor Construction and Operation Generators Relays Switchgear NAO-69 Deleted NAO-70 Deleted NAO-71 Deleted NAO-72 Deleted 4
NAO-73 Nuclear Theory The Atom 2
NAO-74 Nuclear Theory Equivalence of Mass and Energy l
2 NAO-75 Nuclear Theory Radiation 2
NAO-76 Nuclear Theory Interaction of Radiation with Matter i
1 1
TDP-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING DEPARTMENT PROCEDURE DATE: 6/21/85 Pace 29 of 42 TITLE:
NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 2 (Continued)
Nuclear Auxiliary Operator Program CONTACT HOURS LESSON NUMBER TOPIC 2
NAO-77 Nuclear Theory Number of Atoms 2
NAO-78 Nuclear Theory Radioactive Decay 2
NAO-79 Nuclear Theory Induced Nuclear Reactions 2
NAO-80 Nuclear Theory Nuclear Fission 4
NAO-81 Secondary Plant Start-up and Heat-up 4
NAO-82 Secondary Plant Shutdown and Cooldown
P-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING Mf DEPARTMENT PROCEDURE DATE: 6/21/85 Page 30 of 42 b
NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 2 (Continued)
Nuclear Auxiliary Operator Program CONTACT HOURS LESSON NUMBER TOPIC 8
NAO-83 Main Steam System 4
NAO-84 Main Turbine Protection Devices 8
NAO-85 Main and Plant Lube Oil System / Lube Oil Transfer and Purification 8
NAO-86 EHC System 4
NAO-87 Auxiliary Steam System 4
NAO-88 Moisture Separator and Reheat Steam System 4
NAO-89 Extraction Steam System 2
NAO-90 Gland Seal System 2
NAO-91 Gland Water / Condensate Injection System 2
NAO-92 Condensate System 1
NAO-93&
Condensate Heaters and Drains System 1
NAO-94 4
NAO-95 Condensate System l
2 NAO-96 Main Feedwater System 2
NAO-97 Main Feedwater Pump System l
I
DP-201 Rev.3
~'
Florida NUCLEAR OPERATIONS TRAINING D,J DEPARTMENT PROCEDURE DATE: 6/21/85 g
Page 31 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 2 (Continued)
Nuclear Auxiliary Operator Program 1
CONTACT HOURS LESSON NUMBER TOPIC 2
NAO-98 Main Feedwater Pump Lube Oil System 4
NAO-99 Main Feedwater Heaters and Drains System NAO-100 Deleted 2
NAO-101 Cycle Start-Up System 2
NAO-102 Main Generator System 2
NAO-103 Main Generator Exciter System 2
NAO-104 Main Generator and Bus Duct Cooling System 4
NAO-105 Main Generator Seal Oil System 2
NAO-106 Main Transformer and Switchyard System 2
NAO-107 6,900 Volt Bus Distribution System l
2 NAO-108 4,160 Volt Unit Bus Distribution System i
2 NAO-109 480 Volt Unit Bus Distribution System 2
NAO-110 Industrial Cooling System 2
NAO-111 Secondary Ventilation Systems 8
NAO-112 Main Turbine Construction and operation 4
NAO-ll3 OTSG - Secondary Side l
l
- t T P-2ol Rev.3 Rorida NUCLEAR OPERATIONS TRAINING DJ DEPARTMENT PROCEDURE DATE: 6/21/85 Page 32 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 3 Assistant Nuclear Operator Program CONTACT HOURS LESSON NUMBER TOPIC ANO-1 Deleted ANO-2 Deleted 2
ANO-3 Math Review:
Simple Equations and Their Solutions Real Numbers Mononomials and Polynomials 2
ANO-4 Math l
l Review:
Equations and Inequalities of the First Degree in One Variable Geometry and Formulas coordinate Geometry: Graphing Linear Equations and Linear Inequalities 2
ANO-5 Math Review:
Systems of Linear Equations and Linear Inequalities in Two Variables Problem Solving Special Products and Factoring 2
ANO-6 Math Review:
Fractions and Rational Expressions Roots and Radicals Quadratic Equations in One Variable l
I
l
" -2 1 **"'
Florida NUCLEAR OPERATIONS TRAINING g
%f DEPARTMENT PROCEDURE DATE: 6/21/85 Page 33 of 42 TITLE:
NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 3 (Continued)
Assistant Nuclear Operator Program CONTACT HOURS LESSON NUMBER TOPIC 2
ANO-7 Math Review:
Indirect Measurement Laws of Pythagoras, Proportions and similar Triangles 2
ANO-8 Math Logarithms Power, Exponential and Logarithmic Curves 2
ANO-9 Math Angles and Arc Length 2
ANO-10 Math General Angle
~
2 ANO-11 Math Acute Angle 2
ANO-12 Math Tables ANO-13 through 25 Deleted (OJ
TDP-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING f
DEPARTMENT PROCEDURE DATE: 6/21/85 Pace 34 of 42 TITLE:
NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 3 (Continued)
Assistant Nuclear Operator Program CONTACT HOURS LESSON NUMBER TOPIC 4
ANO-26 Nuclear Theory Review:
The Atom Equivalence of Mass and Energy 4
ANO-27 Nuclear Theory Review:
Radiation Interaction of Radiation With Matter 4
ANO-28 Nuclear Theory Review:
Number of Atoms Radioactive Decay 4
ANO-29 Nuclear Theory Review:
Induced Nuclear Reactions Nuclear Fission 4
ANO-30 Nuclear Theory Microscopic Cross Section 4
ANO-31 Nuclear Theory Macroscopic Cross Section and Neutron Flux l
I i
TDP-2ol Rev.3 Florida NUCLEAR OPERATIONS TRAINING j
Mf DEPARTMENT PROCEDURE DATE: 6/21/85 l
Page 35 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM 1
ATTACHMENT 3 (Continued)
Assistant Nuclear Operator Program CONTACT HOURS LESSON NUMBER TOPIC 4
ANO-32 Nuclear Theory Neutron Interactions With Reactor Materials 4
ANO-33 Nuclear Theory Neutron Moderation and Diffusion 4
ANO-34 Nuclear Theory Neutron Multiplication l
4 ANO-35 Nuclear Theory Multiplication Factors I 4
ANO-36 Nuclear Theory Multiplication Factors II 4
ANO-37 Nuclear Theory Reactor Flux Distribution 4
ANO-38 Nuclear Theory Neutron Kinetics 4
ANO-39 Nuclear Theory Reactor Kinetics l
TDP-2ol Rev.3
~
Florida NUCLEAR OPERATIONS TRAINING DJ DEPARTMENT PROCEDURE DATE: 6/21/85 g
Page 36 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 3 (Continued)
Assistant Nuclear Operator Program CONTACT HOURS LESSON NUMBER TOPIC 4
ANO-41 Nuclear Theory Coefficients and Control 4
ANO-42 Nuclear Theory Reactivity Variations 4
ANO-43 Nuclear Theory Fission Product Poisons 4
ANO-44 Nuclear Theory Reactor Core Characteristics 4
ANO-45 Nuclear Theory Fuel Loading and Start-Up 4
ANO-46 Nuclear Theory Power Operation 4
ANO-47 Nuclear Theory Reactor Shutdown l
i 4
ANO-48 Radiation Protection l
Biological Effects of Radiation I
l lI
TDP-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING
%f DEPARTMENT PROCEDURE DATE: 6/21/85 Pace 37 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACEMENT 3 (Continued)
Assistant Nuclear Operator Program CONTACT HOURS LESSON NUMBER TOPIC 4
ANO-49 Radiation Protection Units, Guides and Limits 4
ANO-50 Radiation Protection Protection Techniques 4
ANO-51 Radiation Protection Contamination 4
ANO-52 Radiation Protection Radiation Detection 4
ANO-53 Radiation Protection Detection and Personnel Monitoring 4
ANO-54 Radiation Protection Survey Techniques 4
ANO-55 Radiation Protection In-Plant Monitors 4
ANO-56 Radiation Protection Radioactive Material Control 9
TDP-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING
.P. o...w.. e...f'DEPARTMENT PROCEDURE DATE: 6/21/05 Pace 38 of 42 I TITLE:
NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 3 (Continued)
Assistant Nuclear Operator Program CONTACT HOURS LESSON NUMBER TOPIC 4
ANO-57 Radiation Protection Environmental Considerations and Emergency Planning 4
ANO-58 Chemistry Basic Concepts 4
ANO-59 Chemistry Corrosion of Plant Materials l
l 4
ANO-60 Chemistry Effects of Nuclear Operations 4
ANO-61 Chemistry Chemistry Control Equipment
^
4 ANO-62 Chemistry PWR Primary Water Chemistry 4
ANO-63 Chemistry l
PWR Secondary System Water Chemistry l
l 4
ANO-64 Waste Treatment i
Radioactive Waste 1
l l
- O T P-2ol Rev.3 Florida NUCLEAR OPERATIONS TRAINING DJ DEPARTMENT PROCEDURE DATE: 6/21/85 Page 39 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 3 (Continued)
Assistant _ Nuclear Operator Program CONTACT HOURS LESSON NUMBER TOPIC 4
ANO-65 Waste Treatment Radwaste Discharge 2
ANO-66 Metallurgy Properties of Metals 2
ANO-67 Metallurgy Composition of Alloys 2
ANO-68 Metallurgy Heat Treatment of Metals 2
ANO-69 Metallurgy Brittle Fracture and Metal Damage 2
ANO-70 Metallurgy Testing of Metals 6
ANO-71 Metallurgy Pressure / Temperature Effects (Pressurized Thermal Shock) 2 ANO-72 Metallurgy Irradiation Effects I
I
k TDP-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING DJ DEPARTMENT PROCEDURE DATE: 6/21/85 4
Page 40 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 3 (Continued)
Assistant Nuclear Operator Program CONTACT HOURS LESSON NUHBER TOPIC 4
ANO-73 Plant Start-Uo and Heat-Up 4
ANO-74 Plant Shutdown and Cooldown 2
ANO-75 Reactor Containment and Penetrations System 2
ANO-76 Reactor Containment Ventilation Systems 8
ANO-77 Reactor Vessel and Internals, Fuel and Control Components 2
ANO-78 Reactor Coolant Pump and Motor 2
ANO-79 Pressurizer and System Parameters 2
ANO-80 Once-Through Steam Generator System 4
ANO-81 Reactor Coolant System 4
ANO-82 Make-Up and Purification System 2
ANO-83 Nuclear Services and Decay Heat Raw Water System 4
ANO-84 Nuclear Services Closed Cycle Cooling System 2
ANO-85 Decay Heat Closed Cycle Cooling System 2
ANO-86 Decay Heat Removal System l
I
]
TDP-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING
,DJ DEPARTMENT PROCEDURE DATE: 6/21/85 Page 41 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM l
l ATTACHMENT 3 (Continued)
Assistant Nuclear Operator Program CONTACT HOURS LESSON NUMBER TOPIC 2
ANO-87 Boric Acid System 4
ANO-88 Primary Chemical Addition and Sampling System 4
ANO-89 Emergency Core Cooling System 2
ANO-90 Reactor Building Spray System 2
ANO-91 Reactor Building Isolation and Cooling System 4'
ANO-92 Waste Evaporators 4
ANO-93 Liquid Waste System 4
ANO-94 Gas Waste System 2
ANO-95 Solid Waste System 2
ANO-96
!!2_ Supply 4
ANO-97 Spent Fuel Storage and Cooling System 4
ANO-98 Auxiliary Building Fuel Handling System 4
ANO-99 Reactor Building Fuel Handling System 2
ANO-100 Leak Rate Test System 2
ANO-101 Auxiliary Building Ventilation System l
- 9 TDP-201 Rev.3 Florida NUCLEAR OPERATIONS TRAINING
(
f DEPARTMENT PROCEDURE DATE: 6/21/85 Page 42 of 42 NON-LICENSED OPERATOR TRAINING PROGRAM ATTACHMENT 3 (Continued)
Assistant Nuclear Operator Program CONTACT HOURS LESSON NUMBER TOPIC 2
ANO-102 Control Complex Chiller System 2
ANO-103 Control Complex Ventilation System 4
ANO-104 Radiation Monitoring System 4
ANO-105 Emergency Diesel System Engine 4
ANO-106 Emergency Diesel System Generator 2
ANO-107 Reactor / Auxiliary Building Drains and Sumps 2
ANO-108 4,160 Volt ES Bus Distribution System 2
ANO-109 480 Volt ES Bus Distribution System ANO-llo Station Battery System 2
2 ANO-111 250/125 Volt DC Distribution System 2
ANO-112 120 Volt Vital Bus Distribution System 4
ANO-113 Emergency Feedwater System 2
ANO-114 Electrical Heat System 4
ANO-ll5 Post Accident Sampling System and H2 Monitoring 8
ANO-ll6 Plant Transients and Integrated Plant O
--