Rev 2 to Procedure CP-QP-2.6 Certification of Csts Personnel
ML20138P087
Person / Time
Site: Comanche Peak, 05000000
Issue date: 05/15/1984
From:
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
Shared Package
ML20138M609 List: ... further results
References
FOIA-85-59 CP-QP-2.6, NUDOCS 8511060385
Download: ML20138P087 (6)


Text

-

e PROCEDURE ISSUE REVISION TEXAS UTIUTIES GENERATING CO NUMBER CATE PAGE l

P-QP-2.6 2

I f6 M15Egf I

/

9

/

PREPARED d

(

CERTIFICATION OF

/

^

UATE j

CSTS PERSONNEL 7

APPROVED BY:

/ AA 6

mornmica MxPY vi

~

OATE '

VUlllW' "

"' ~

CONTROL No h4 CO1

1.0 REFERENCES

1-A CP-Q P-19.6, "Suneillance of Cons truction and Startup/

Turnover Activities" 1-8 CP-QP-2.1, " Training of Inspection Personnel" 1-C C P-Q P-2. 3,

" Documentation Within QA/QC Personnel Qualification File" 2.0 GENERAL 2.1 PURPOSE The purpose of this procedure is to establish the minimum requirements for training, qualification, and certification of personnel assigned to suneillance of construction and startup/ turnover activities in accordance with Reference 1-A.

3.0 PROCEDURE 3.1 EDUCATION AND EXPERIENCE Certification as a Surveillance Specialist requires:

a.

High school graduation plus six years experience in a technical field with at least two years experience in nuclear quality assurance; or:

b.

An associates degree fran an accredi ted institution in engineering, physical science, mathematics, or quality assu rance wi th at least four years of experience, two of which must be nuclear quality i

assurance; or:

I c.

Bachelors degree fram an accredi ted institution in engineering, physical

sciences, mathematics, or quali ty assurance with at least two years experience in nuclear quality assurance.

TUCCC CA g 10 g 5 851016 GARDE 85-59 PDR

j PROCEDURE ISSUE REVISION PAGE NUMBER DATE TEXAS UTILITIES GENERATING CO.

CMES CP-Q P-2.6 2

gay 15 ElH 2 of 6 l

3.2 INDOCTRINATION

]

Persons assigned to su rveillance of cons truction and i

startup/ turnover activities shall receive the following l

indoctrination as required by Reference 1-B:

a.

QA/QC orientation

" Introduction to Nuclear Power Codes i

and Standards," completion to be doctsnented by entry on.

b.

General knowledge of documents listed on Attachment 2 and a working knowledge of Reference 1-A Personnel shall also have a working knowledge of the following documents as ' applicable to their area of surveillance:

1). Operations Administrative Control and QA Plan 2). Station Administration Manual 3). TUGC0 Construction QA Procedures 4). Startup QA Plan 5). CPSES QA Plan 6). B&R QA Manual 7). CPSES Section XI Program Manual Completion of required s tudy is to be documented on.

3.3 TRAINING l

After completing the indoctrination program, each trainee shall be required to participate in at least two site suneillance activites conducted by certified surveillance l

1 personnel.

3.4 CERTIFICATION l

Upon completion of the training program, the trainee will i

be interviewed by the CSTS Supervisor or his designee to detennine the individual's qualifications in the following areas:

a.

Surveillance planning l

ruoco oA I _ _.. _ _... _,._,.__..__ _.___,

TEXAS UTILITIES GENERATING CO.

CP-Q P-2.6 2

MAY 1 5 684 3 of 6 4

t b.

Checklist preparation c.

Performance of surveillance activities d.

Follow-up and closeout of discrepancies Surveillance Certification (Attachment 3) qualified, the If it is detemined the trainee is QA will be signed by the CSTS Supervisor and approved by the TUGC0 Site QA Manager.

i Certification will be for a period of one year.

3.5 DOCUMENTATION Records of training and certification (Attachments 1, 2 and 3) will be filed and maintained in accordance with Reference 1-C.

I i

4 i

TUGCC CA p

m:

i

INSTRUCTION ISSUE REVISION PAGE NUMSER CATE i

TEXAS UTtuTIES GENERATING CO.

2 gay 15 W CP-QP-2.6 4 of 6 4

ATTACHMENT 1 C

u a

TRAINING RECORD C0fweE PEAK STEN 4 ELECTRIC STAf!CN CATE:

i l

M tsCER$1GNED ACKNDH. EDGE RECE!PT OF SPECIALIZED TPAINING IN:

I G!vEN SY:

(INSTRUCTOR) THis CATE, AT CDrW O E PEAK PROJECT.

i m ire??m) s tc?utTwc ejncE 1 y

i l

I I

1 1

i i

4

)

J l

I 1

}NSTRUCTOR'$ 5tGt;AftpE l b s$ OF TRAINltr L__

. lit _

l I

N" muun sem i I

INSTRUCTION ISSUE REVISION pagg NUMSER DATE TEXA8 UTtuTIES GENERATING CO.

CPSES g 15 CP-QP-2.6 2

5 of 6 ATTACHMENT 2 1

I i

COMANCHE PEAN STEAM ELECTRIC STATION CENERAL TRAINING OUTLINE TO BE COMP!.ETED BY:

l (60 Days Atter Espioyment)

J l

NAME DOCUMENTt l

1.

Final Safety Analysis Report Chapter (s) 17, 2.

Title 10 code of rederst Regulations Part $0, Appendix 3 and ANSI N45.2 l

3.

NRC Regulatory Guides (As Assigned)*

g e

i j

4.

Industry Standards (As Assignedl

  • g e

e 3.

CA/QC Procedures and Instructions l

(As Assigned)*

e e

i 4.

Title 10 code of rederst Regulations, 4

Part 21 and 10CFR50.55E 7

Other applicable documents as listed belows i

i i

VER!r!ED BY DATE OUT!.!NE APPROVED 8Y:

R. G. Tolson DATE

  • NOTE: If Item 'NOT APPLICABLE
  • so State on outline.

f MM f

.._- _.,. _ m._ _ _ _, _.. _. _,, _, _ _., _, _... - _. _ _. _,,

INSTRUCTION ISSUE REVISION NUMBER DATE PAGE

CPSES QI-QP-2.6 2

ny 5 684 6 of 6

)

ATTACHMENT 3

.i 1

1 1

TEXA5 UTILITIES GENERATING COMPANY 00ALITY ASSURANCE DEPAATMENT QA SURVEILLANCE CERTIFICATION 1

i MME:

DATE TUSCO PROCEDURE /INSTRUCITON Nv.

j TYPE OF EXAMINATION GIVEN:

ORAL WRITTEN PRACTICAL E SULTS OF EIAMINATION(s) l ComENTS:

l i

i i

i i

}

This certification will expire on I

3Weervil0F l

Approvai 1

+

i I

s I

I i

i TUSCO CA l

l m