ML20031C459

From kanterella
Jump to navigation Jump to search

Forwards Application for Amend to License DPR-72,consisting of Tech Spec Change Request 75 to Require Monthly Exercise of All not-inserted Control Rods to Verify Absence of Significant Mechanical Obstructions.Class IV Amend Fee Encl
ML20031C459
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 09/24/1981
From: Hancock J
FLORIDA POWER CORP.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20031C460 List:
References
3-091-23, 3-91-23, TAC-46973, TAC-46975, NUDOCS 8110070170
Download: ML20031C459 (4)


Text

,

see ok EEitL,fk

<r

  • > O O L ' 0 0 =

o e

Florida m

g611 N',/ g Power S

C O R Fo m a t io N f

File:

3-0-3-a-3 G %((

September 24, 1981 OCT g

  1. 3-091 -23

.x x

w...

.v Director

[ j ' uY

Office of Nuclear Reacte-Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

Crystal River Unit 3 Docket No. 50-302 Operating License No. DPR-72 Technical Specification Change Request No. 75

Dear Sir:

Enclosed Technical Specification Change Request No. 75 requests an amendment to Appendix A of Operating License No. DPR-72.

As part of this request, proposed replacement pages for Appendix A are enclosed.

The change affects Crystal River Unit 3, Technical Specificatica 4.1.3.1.2.

This specification requires monthly exercise of all not-inserted control rods to verify the absence of significant mechanical obstructions which would affect i

rod insertion and drop times assumed in various safety analyses. A margin of

  • 25% is allowed on the frequency of st tests. The next scheduled test (including the +25% margin) would be required by September 25, 1981.

While attempting to perform this test on September 22, 1981, the seal leakoff i

from reactor coolant pump 3Al increased from 1.0 gpm to 1.9 gpm.

This is considered to be a result of RCS pressure ose'.1ations of around 20 psi due to theunitbeingcontrolledbyfeedwaterfiwvs.T,[rather.hanrodmotion ve T when the rods are taken into manual contro rather than automatic wontrol.

av Feedwater control has a much longer response time than rod motion control and, therefore, allows normal system oscillations to increase in magnitude.

Continual degradation of the reactor coolant pump seals is considered to be a potential j00,j safety concern; and, therefore, Florida Power Corporation is hereby requesting /7 an extension to the surveillance inM rval of 3 days until the beginning of our

.5 planned refueling outage on Septc ber 27, 1981.

w/c/s.ft 9110070170 810924-h Yooo.so PDR ADOCK 05000302 p

PDR.

General Office 3201 inirty fourth street soutn. P O Box 14042, St Petersburg Fionda 33733 813-866-5151

Page 2 Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission September 24, 1981 Florida Power Corporation considers Change Request No. 75 to be a Class IV amendment per 10CFR170.22.

The license fee in the amount or four thousand dollars ($4,000.00) and a signed copy of Certificate of Serv.cc for Technical Specification Change Request No. 75 to the Ch!.ef Executive of Citrus County, Florida, are enclosed.

Very truly yours, 7

FLO A POI CORPORATION j

k,{

J an A. Hancock

' ssistant Vice President Nuclear Operations KFP:cmd Enclosures

STATE OF FLORIDA j

COUNTY OF CITRUS J.A. Hancock states that he is the Assistant Vice President, Nuclear Operations of Florida Power Corporation; that he is authorized on the part of said company to sign and file with the Nuclear Regulatory Commission the information attached hereto; and that all such statements made and matters set forth therein are true and correct to the best of his knowledge, information and belief.

i v

.. Hancock i

Subscribed and sworn to before me, a Notary Public in and for the State and County above named, this 24th day of September,1981.

4 C

1) l W

Notary Public i

Notary Public, State of Florida at Large, My Commission Expires: September 16, 1983 JAH/LBNotary(DN-98)

D F


]

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION IN THE MATTER OF

)

)

DOCKET N0. 50-302 FLORIDA POWER CORPORATION

)

CERTIFICATE OF SERVICE J.A. Hancock deposes and says that the follawing has been served on the Chief Executive of Citia Cocnty, Florida by deposit in the United States mail, addressed as fo. lows:

Chairman, Board of County Commissioners of Citrus County Citrus County Courthouse Inverness, Florida 32650 An original copy of a letter submitting Technical Specification Change Request No. 75 v'equesting an amendment to Appendix A of Operating License No. DPR-72.

l FLORIDA POWER CORPORATION Y

a isat ce t

Nuclear Operations SWORN TO AND SUBSCRIBED BEFORE ME THIS 24TH DD OF SFPTEMBER, 1981.

WMb0 Notary Public Notary Public State of Florida at Large My Consnission expires: Septenher 16, 1983 (NOTARIALSEAL) i j

(Cert. Serv.D12) l -.. _, _,.

..