ML18120A024
| ML18120A024 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 04/06/2018 |
| From: | Exelon Generation Co |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML18117A343 | List:
|
| References | |
| TMI-18-047 | |
| Download: ML18120A024 (9) | |
Text
ATTACHMENT 3-7A MANUAL ACTIONS REQUIRED FOR HOT SHUTDOWN IN APPENDIX R III.G.2 FIRE AREAS/ZONES (NOTE 5)
Page 1 FHAR Rev 27 (1)
System Function (2)
Condition which requires action (Equipment Failure):
(3)
Applicable Fire Area / Zones:
(4)
Action Required (Note 1):
(5)
Location where Action is Performed:
(6)
Time Requirement (7)
Time Requirement Bases (8)
Exemption Approval/SER (9)
Exemption Request (Applicable Fire Areas/Zones)
(10)
Emergency Light(s)
Required for Action EFW Control EF-V-30A spuriously closes due to hot short or loss of 2 Hr Backup IA CB-FA-2g, FH-FZ-5, IB-FZ-2, DG-FA-2 Establish local control of EF-V-30A IB-FZ-3 20 Min GPU memo 5520-85-0520 5211-87-3066 5211-87-2021 EL-L-8 EFW Control EF-V-30B spuriously closes due to hot short or loss of 2 Hr Backup IA CB-FA-2g, FH-FZ-5, IB-FZ-2, DG-FA-2 Establish local control of EF-V-30B IB-FZ-3 20 Min GPU memo 5520-85-0520 5211-87-3066 5211-87-2021 EL-L-83 EFW Control EF-V-30C spuriously closes due to hot short or loss of 2 Hr Backup IA CB-FA-2g, FH-FZ-5, IB-FZ-2, DG-FA-2 Establish local control of EF-V-30C IB-FZ-3 20 Min GPU memo 5520-85-0520 5211-87-3066 5211-87-2021 EL-L-83 EFW Control EF-V-30D spuriously closes due to hot short or loss of 2 Hr Backup IA CB-FA-2g, FH-FZ-5, IB-FZ-2, DG-FA-2 Establish local control of EF-V-30D IB-FZ-3 20 Min GPU memo 5520-85-0520 5211-87-3066 5211-87-2021 EL-L-8 EFW Control Loss of normal IA supply to EF-V-30A All fire areas/zones where a loss of normal Instrument Air is possible (See -0)
Establish local control of EF-V-30A IB-FZ-3 2 Hrs For IB-FZ-3 & IB-FZ-8, basis is maximum time available to restore EFW if HPI cooling is required For all other fire areas/zones, basis is maximum local IA supply capacity 5211-86-3333 5211-86-2124 (IB-FZ-3/8)
EL-L-8 C311-87-3066 5211-87-2021 (All others)
EFW Control Loss of normal IA supply to EF-V-30B All fire areas/zones where a loss of normal Instrument Air is possible (See -0)
Establish local control of EF-V-30B IB-FZ-3 2 Hrs For IB-FZ-3 & IB-FZ-8, basis is maximum time available to restore EFW if HPI cooling is required For all other fire areas/zones, basis is maximum local IA supply capacity 5211-86-3333 5211-86-2124 (IB-FZ-3/8)
EL-L-83 C311-87-3066 5211-87-2021 (All others)
EFW Control Loss of normal IA supply to EF-V-30C All fire areas/zones where a loss of normal Instrument Air is possible (See -0)
Establish local control of EF-V-30C IB-FZ-3 2 Hrs For IB-FZ-3 & IB-FZ-8, basis is maximum time available to restore EFW if HPI cooling is required For all other fire areas/zones, basis is maximum local IA supply capacity 5211-86-3333 5211-86-2124 (IB-FZ-3/8)
EL-L-83 C311-87-3066 5211-87-2021 (All others)
ATTACHMENT 3-7A MANUAL ACTIONS REQUIRED FOR HOT SHUTDOWN IN APPENDIX R III.G.2 FIRE AREAS/ZONES (NOTE 5)
Page 2 FHAR Rev 27 (1)
System Function (2)
Condition which requires action (Equipment Failure):
(3)
Applicable Fire Area / Zones:
(4)
Action Required (Note 1):
(5)
Location where Action is Performed:
(6)
Time Requirement (7)
Time Requirement Bases (8)
Exemption Approval/SER (9)
Exemption Request (Applicable Fire Areas/Zones)
(10)
Emergency Light(s)
Required for Action EFW Control Loss of normal IA supply to EF-V-30D All fire areas/zones where a loss of normal Instrument Air is possible (See -0)
Establish local control of EF-V-30D IB-FZ-3 2 Hrs For IB-FZ-3 & IB-FZ-8, basis is maximum time available to restore EFW if HPI cooling is required For all other fire areas/zones, basis is maximum local IA supply capacity 5211-86-3333 5211-86-2124 (IB-FZ-3/8)
EL-L-8 C311-87-3066 5211-87-2021 (All others)
Electrical Power /
Component Cooling EG-Y-1A is operating (Area ventilation (AH-E-29A) is inoperable)
CB-FA-1, CB-FA-2d, CB-FA-2f, IB-FZ-3, IB-FZ-5, DG-FA-2 Open Doors D106 & D107 DG-FA-1 1 Hr TDR 900 C311-88-3225 C311-88-2010 EL-L-5 Electrical Power /
Component Cooling EG-Y-1B is operating (Area ventilation (AH-E-29B) is inoperable)
CB-FA-1, CB-FA-2d, CB-FA-2f, IB-FZ-3, IB-FZ-5, DG-FA-2 Open Doors D101, SB157, SB145, and SB147 DG-FA-2 1 Hr TDR 900 C311-88-3225 C311-88-2010 EL-L-6 Electrical Power /
Component Cooling Loss of both trains of Control Building cooling (fans or chillers)
CB-FA-1, CB-FA-2d, CB-FA-2f Open CT-2 breakers E2, 6, E6 CB-FA-4b 1 Hr DR5375339A-2 TDR 900 5211-87-3066, C311-88-3225 C311-88-2010 EL-L-21A Electrical Power /
Component Cooling Loss of both trains of ISPH cooling (AH-E-27A/B)
CB-FA-3b, FH-FZ-1, ISPH-FZ-1, ISPH-FZ-2, ISPH-FZ-3 Establish Portable Ventilation ISPH-FZ-1, ISPH-FZ-2 4 Hrs ECR 08-00728.
5211-87-3066 5211-87-2033, 5211-87-2047, 5211-87-2175 EL-L-20 EL-L-35 Electrical power Maintain availability of vital bus VBA and VBC (Loss of 1A ES MCC)
CB-FA-2a, CB-FA-3a Cross tie DC system CB-FA-2c, CB-FA-2d, CB-FA-2e, CB-FA-2f, CB-FA-2g, CB-FA-4b 2 Hrs Battery design basis duty cycle is 2 Hrs ECR 05-00671 Not required per RG 1.189 Rev.2.
One train of required instruments remains available without this action Not Required.
EL-L-80A/B EL-L-15 EL-L-16 Electrical power Maintain availability of vital bus VBB and VBD (Loss of 1B ES MCC)
CB-FA-2b, CB-FA-3b Cross tie DC system CB-FA-2c, CB-FA-2d, CB-FA-2e, CB-FA-2f, CB-FA-2g, CB-FA-4b 2 Hrs Battery design basis duty cycle is 2 Hrs ECR 05-00671 Not required per RG 1.189 Rev.2.
One train of required instruments remains available without this action Not required EL-L-80A/B EL-L-15 EL-L-16 Letdown Letdown is required (NOTE 2)
RB-FZ-2, CB-FA-1, FH-FZ-5 Locally open MU-V-1A or MU-V-1B to lineup one letdown cooler RB-FZ-1c 4 Hrs Historical NRC approved time limit to restore letdown 5211-86-3333 5211-86-2124 (RB-FZ-2, FH-FZ-5)
EL-L-109 (portable)
ATTACHMENT 3-7A MANUAL ACTIONS REQUIRED FOR HOT SHUTDOWN IN APPENDIX R III.G.2 FIRE AREAS/ZONES (NOTE 5)
Page 3 FHAR Rev 27 (1)
System Function (2)
Condition which requires action (Equipment Failure):
(3)
Applicable Fire Area / Zones:
(4)
Action Required (Note 1):
(5)
Location where Action is Performed:
(6)
Time Requirement (7)
Time Requirement Bases (8)
Exemption Approval/SER (9)
Exemption Request (Applicable Fire Areas/Zones)
(10)
Emergency Light(s)
Required for Action (MU-V-1A and MU-V-1B are closed, and are remotely inoperable)
C311-88-3225 5211-87-2175 (CB-FA-1)
Letdown Letdown is required (NOTE 2)
(MU-V-2A and MU-V-2B are closed, and are remotely inoperable)
CB-FA-1, CB-FA-2b, CB-FA-2c, FH-FZ-5 Locally open MU-V-2A or MU-V-2B to lineup one letdown cooler RB-FZ-1c 4 Hrs Historical NRC approved time limit to restore letdown 5211-87-3066 5211-87-2021 (CB-FA-2c)
EL-L-109 (portable)
C311-88-3225 5211-87-2175 (CB-FA-1) 5211-86-3333 5211-86-2124 (CB-FA-2b, FH-FZ-5)
Letdown Letdown is required (NOTE 2)
(MU-V-3 is closed and is remotely inoperable)
CB-FA-1, CB-FA-2b, FH-FZ-5, PLUS (due to loss of normal Instrument Air only):
IB-FZ-3, IB-FZ-8, TB-FA-1 Locally open MU-V-3 AB-FZ-4 4 Hrs Historical NRC approved time limit to restore letdown 5211-87-3066 5211-87-2021 (CB-FA-1)
EL-L-293 C311-88-3225 5211-87-2175 (FH-FZ-5 and all loss of IA) 5211-86-3333 5211-86-2124 (CB-FA-2b)
Letdown Letdown is required (NOTE 2)
(MU-V-4 is closed and is remotely inoperable)
CB-FA-1 PLUS (due to loss of normal Instrument Air only):
IB-FZ-3, IB-FZ-8, TB-FA-1 Locally open MU-V-98 AB-FZ-3 4 Hrs Historical NRC approved time limit to restore letdown 5211-86-3333 5211-86-2124 (CB-FA-1)
EL-L-89A C311-88-3225 5211-87-2175 (All loss of IA)
Letdown Letdown is required (NOTE 2)
(MU-V-5 is closed and is remotely inoperable)
CB-FA-1, FH-FZ-5 PLUS (due to loss of normal Instrument Air only):
IB-FZ-3, IB-FZ-8, TB-FA-1 Locally open MU-V-98 AB-FZ-3 4 Hrs Historical NRC approved time limit to restore letdown 5211-86-3333 5211-86-2124 (CB-FA-1, FH-FZ-5)
EL-L-89A C311-88-3225 5211-87-2175 (All loss of IA)
Letdown Letdown is required (NOTE 2)
(MU-V-6A and MU-V-6B are closed, and are remotely inoperable)
FH-FZ-5 PLUS (due to loss of normal Instrument Air only):
CB-FA-1, IB-FZ-3, IB-FZ-8, TB-FA-1 Locally open MU-V-70A AB-FZ-6 4 Hrs Historical NRC approved time limit to restore letdown 5211-86-3333 5211-86-2124 (FH-FZ-5)
EL-L-94 C311-88-3225 5211-87-2175 (All loss of IA)
Letdown Letdown is required (NOTE 2)
FH-FZ-5 PLUS (due to loss of normal Instrument Locally open MU-V-110 AB-FZ-5 4 Hrs Historical NRC approved time limit to restore letdown 5211-86-3333 5211-86-2124 (FH-FZ-5)
EL-L-88A
ATTACHMENT 3-7A MANUAL ACTIONS REQUIRED FOR HOT SHUTDOWN IN APPENDIX R III.G.2 FIRE AREAS/ZONES (NOTE 5)
Page 4 FHAR Rev 27 (1)
System Function (2)
Condition which requires action (Equipment Failure):
(3)
Applicable Fire Area / Zones:
(4)
Action Required (Note 1):
(5)
Location where Action is Performed:
(6)
Time Requirement (7)
Time Requirement Bases (8)
Exemption Approval/SER (9)
Exemption Request (Applicable Fire Areas/Zones)
(10)
Emergency Light(s)
Required for Action (MU-V-11A and MU-V-11B are closed, and are remotely inoperable)
Air only):
IB-FZ-3, IB-FZ-8, TB-FA-1 C311-88-3225 5211-87-2175 (All loss of IA)
Makeup Loss of all NR pumps ISPH-FZ-1 Transfer NR-P-1C control to RSD panel and start NR-P-1C CB-FA-2b, CB-FA-2c 30 Min See Note 3.
5211-87-3066 5211-87-2021 EL-L-78 EL-L-79B Letdown Support Letdown is required (Note 2)
(Loss of 1T 480V SWGR)
CB-FA-2b Swap breakers to supply NR-P-1B from 1R 480V ISPH-FZ-1 ISPH-FZ-2 4 Hrs Tech Eval 09-00030 NRC letter dated March 30, 2009 5928-08-20023 TMI-09-008 EL-L-20 EL-L-35 Letdown Support Letdown is required.
(Note 2)
(NR-V-15A spuriously closes and NR-V-15B fails closed)
IB-FZ-8, TB-FA-1, CB-FA-2b Locally throttle NR-V-15A or NR-V-15B AB-FZ-1 4 Hrs Historical NRC approved time limit to restore letdown 5211-87-3066 5211-87-2021 EL-L-93 Letdown Support Letdown is required.
(Note 2)
(IC-V-2 spurious closure due to hot short)
CB-FA-2b, CB-FA-2c Locally open IC-V-2 RB-FZ-1c 4 Hrs Historical NRC approved time limit to restore letdown 5211-87-3066 5211-86-2124 (CB-FA-2b)
EL-L-109 (Portable) 5211-87-3066 5211-87-2021 (CB-FA-2c)
Letdown Support Letdown is required.
(Note 2)
(IC-V-3 closes due to loss of IA OR due to a hot short)
Due to loss of normal Instrument Air only:
CB-FA-1, IB-FZ-3, IB-FZ-8, TB-FA-1 Locally open IC-V-3 AB-FZ-4 4 Hrs Historical NRC approved time limit to restore letdown C311-88-3225 5211-87-2175 (All loss of IA for fire areas/zones where letdown is required)
EL-L-91 EL-L-91A Letdown Support Letdown is required.
(Note 2)
(IC-V-3 spurious closure due to hot short)
CB-FA-2b Open 1E Panel Switch #15 to fail open IC-V-3 CB-FA-2d 4 Hrs Historical NRC approved time limit to restore letdown 5211-86-3333 5211-86-2124 EL-L-80 Letdown Support Letdown is required.
(Note 2)
(IC-V-4 closes due to loss of IA OR due to a hot short)
Due to loss of normal Instrument Air only:
CB-FA-1, IB-FZ-3, IB-FZ-8, TB-FA-1 Locally open IC-V-4 AB-FZ-7 4 Hrs Historical NRC approved time limit to restore letdown C311-88-3225 5211-87-2175 (All loss of IA for fire areas/zones where letdown is required)
EL-L-307 Letdown Support Letdown is required.
(Note 2)
(IC-V-4 closes due to a hot short)
CB-FA-2b Open 1M Panel Switch #5 to fail valve open CB-FA-2c 4 Hrs Historical NRC approved time limit to restore letdown 5211-86-3333 5211-86-2124 (CB-FA-2b)
EL-L-79A
ATTACHMENT 3-7A MANUAL ACTIONS REQUIRED FOR HOT SHUTDOWN IN APPENDIX R III.G.2 FIRE AREAS/ZONES (NOTE 5)
Page 5 FHAR Rev 27 (1)
System Function (2)
Condition which requires action (Equipment Failure):
(3)
Applicable Fire Area / Zones:
(4)
Action Required (Note 1):
(5)
Location where Action is Performed:
(6)
Time Requirement (7)
Time Requirement Bases (8)
Exemption Approval/SER (9)
Exemption Request (Applicable Fire Areas/Zones)
(10)
Emergency Light(s)
Required for Action Letdown Support Letdown is required.
(Note 2)
CB-FA-2b Place 69/IC-P-1A in the EMERG position CB-FA-2e 4 Hrs Historical NRC approved time limit to restore letdown 5211-86-3333 5211-86-2124 EL-L-76A Makeup Pump Protection Maintain MU pump minimum flow path (MU-V-36 spuriously closes and loss of IA to MU-V-20)
AB-FZ-6 Open 1P 480V switchgear Unit 4C and locally open MU-V-36 CB-FA-2a AB-FZ-3 40 Min ECR 07-00792 NRC ADAMS ML101310113 NRC ADAMS ML090630134 ML100750093 EL-L-76B EL-L-89B Makeup Pump Protection Maintain MU pump minimum flow path (MU-V-36 spuriously closes due to hot short)
CB-FA-2b Locally open MU-V-36 AB-FZ-3 2 Hrs (See Att. 3-3 Note 6)
Letter from pump manufacturer indicates seal injection flow is adequate to maintain pump minimum flow.
5211-86-3333 5211-86-2124 EL-L-89B 5211-87-3066 5211-86-2021 (Corrected time from original exemption from 1 Hr. to 2 Hrs.)
Makeup Pump Protection Maintain MU pump minimum flow path (MU-V-37 spuriously closes due to hot short)
AB-FZ-2c, AB-FZ-6a, CB-FA-2b, CB-FA-2c, CB-FA-2e, CB-FA-2g, CB-FA-3b Locally open MU-V-37 AB-FZ-3 2 Hrs (See Att. 3-3 Note 6)
Letter from pump manufacturer indicates seal injection flow is adequate to maintain pump minimum flow.
C311-88-3225 5211-87-2175 (CB-FA-3b)
EL-L-89B 5211-86-3333 5211-86-2124 (AB-FZ-6a, CB-FA-2b) 5211-87-3066 5211-87-2021 (All others and corrected time to 2 Hrs)
RCS Heat Removal MS-V-4A spurious closure due to hot short or loss of IA All fire areas/zones where a loss of normal Instrument Air is possible (See -0) PLUS CB-FA-2d, CB-FA-3a, CB-FA-3b, IB-FZ-2, IB-FZ-6, TB-FA-1 Locally operate MS-V-4A to control OTSG pressure IB-FZ-2 3 Hrs Historical NRC approved time limit to establish ADV control 5211-86-3333 5211-86-2124 (IB-FZ-2/6, CB-FA-2d/3a/3b, TB-FA-1)
EL-L-84A C311-88-3225 5211-87-2175 (All loss of IA plus CB-FA-2c)
RCS Heat Removal MS-V-4B spurious closure due to hot short or loss of IA All fire areas/zones where a loss of normal Instrument Air is possible (See -0) PLUS CB-FA-2b, CB-FA-2c, CB-FA-2d, CB-FA-3a, CB-FA-3b, FH-FZ-5, IB-FZ-2, IB-FZ-3, IB-FZ-6, TB-FA-1 Locally operate MS-V-4B to control OTSG pressure IB-FZ-2 3 Hrs Historical NRC approved time limit to establish ADV control 5211-86-3333 5211-86-2124 (IB-FZ-2/3/6, CB-FA-2c/2d/3a/3b, FH-FZ-5, TB-FA-1)
EL-L-84A Or EL-L-84B C311-88-3225 5211-87-2175 (All loss of IA plus CB-FA-2b)
ATTACHMENT 3-7A MANUAL ACTIONS REQUIRED FOR HOT SHUTDOWN IN APPENDIX R III.G.2 FIRE AREAS/ZONES (NOTE 5)
Page 6 FHAR Rev 27 (1)
System Function (2)
Condition which requires action (Equipment Failure):
(3)
Applicable Fire Area / Zones:
(4)
Action Required (Note 1):
(5)
Location where Action is Performed:
(6)
Time Requirement (7)
Time Requirement Bases (8)
Exemption Approval/SER (9)
Exemption Request (Applicable Fire Areas/Zones)
(10)
Emergency Light(s)
Required for Action RCS Inventory Control Loss of all RCP seal cooling AND RCP and 6900V swgr remote trip unavailable CB-FA-1 Locally trip RCPs at 6900V Switchgear TB-FA-1 30 Min Design Specification for Flowserve N-9000 RCP Seals SP-1101-12-170 Rev. 0 NRC letter dated March 30, 2009 (Historical -
based on previous RCP seal design)
NOTE 5 5928-08-20023 TMI-09-008 (Historical -
based on previous RCP seal design)
EL-L-72A EL-L-72B RCS Inventory Control Maintain RCS makeup capability (All MU-Pumps shutdown, and MU-P-1A/C are not operable)
AB-FZ-5, AB-FZ-7, ISPH-FZ-1, ISPH-FZ-2 Select MU-P-1B for ES at 1E 4160V switchgear and start from CR CB-FA-3b 1 Hr 86-9101191-001 (Loss of makeup with a loss of all RCP seal cooling)
Not required per RG 1.189 Rev.2.
Action utilizing equipment specifically designed with local controls is not considered an operator manual action.
Not required EL-L-25A RCS Inventory Control RCS makeup is required to maintain pressurizer level (Normal makeup lost AND MU-V-16A/B fail closed AND MU-P-1C unavailable)
AB-FZ-6 Open 1P 480V switchgear Unit 4C breaker AND Locally throttle MU-V-16B CB-FA-2a AB-FZ-4 1 Hr 86-9101191-001 (Loss of makeup with a loss of all RCP seal cooling)
NRC ADAMS ML101310113 NRC ADAMS ML090630134 ML100750093 EL-L-76B EL-L-293 2 Hrs Historical NRC approved time limit to restore makeup with RCP seal cooling available 5211-86-3333 5211-86-2124 RCS Inventory Control Maintain RCS makeup capability (MU-V-14A or MU-V-14B cannot be remotely opened)
AB-FZ-4 Locally open MU-V-14A or MU-V-14B AB-FZ-4 2 Hrs Historical NRC approved time limit to restore makeup with RCP seal cooling available 5211-86-3333 5211-86-2124 EL-L-90 RCP Seal Cooling MU-V-20 spurious closure due to hot short or loss of IA AB-FA-1, AB-FZ-10, AB-FZ-2, AB-FZ-5, AB-FZ-7, AB-FZ-9, CB-FA-1, CB-FA-2b, CB-FA-2d, CB-FA-2f, CB-FA-3a, DG-FA-2, FH-FZ-1, FH-FZ-3, FH-FZ-4, FH-FZ-6, IB-FZ-1, IB-FZ-2, IB-FZ-3, IB-FZ-4, IB-FZ-5, IB-FZ-6, IB-FZ-8, ISPH-FZ-1, ISPH-FZ-2, ISPH-FZ-3, TB-FA-1 Ensure MU-V-20 is open under local control FH-FZ-2 1 Hr Tech Eval 14-00408 NOTE 5 NOTE 5 EL-L-292 AB-FZ-3, AB-FZ-4, AB-FZ-6, FH-FZ-2 When accessible, ensure MU-V-20 is open under local control 2..5 Hr RCP Seal Cooling MU-P-1A or MU-P-1B is not available CB-FA-1, CB-FA-2a, CB-FA-2d, CB-FA-2f, CB-FA-3a, DG-FA-1, FH-FZ-1, FH-FZ-6 Open MU-V-76A and MU-V-76B AB-FZ-3 1 Hr Tech Eval 14-00408 NOTE 5 NOTE 5 EL-L-89B AB-FZ-3 When accessible, Open MU-V-76A and MU-V-76B 2.5 Hr
ATTACHMENT 3-7A MANUAL ACTIONS REQUIRED FOR HOT SHUTDOWN IN APPENDIX R III.G.2 FIRE AREAS/ZONES (NOTE 5)
Page 7 FHAR Rev 27 (1)
System Function (2)
Condition which requires action (Equipment Failure):
(3)
Applicable Fire Area / Zones:
(4)
Action Required (Note 1):
(5)
Location where Action is Performed:
(6)
Time Requirement (7)
Time Requirement Bases (8)
Exemption Approval/SER (9)
Exemption Request (Applicable Fire Areas/Zones)
(10)
Emergency Light(s)
Required for Action RCP Seal Cooling Loss of remote control of MU-V-32 CB-FA-1, CB-FA-2d, CB-FA-2f, FH-FZ-1, FH-FZ-5 Close MU-V-89A and Throttle MU-V-90 AB-FZ-3 1 Hr Tech Eval 14-00408 NOTE 5 NOTE 5 EL-L-89B AB-FZ-3, FH-FZ-2 When accessible, Close MU-V-89A and Throttle MU-V-90 2.5 Hr RCS Pressure Control /
Makeup Pump Protection Prevent excessive RCS pressure and maintain MU pump minimum flow path (MU-V-16A/B spurious opening and MU-V-36/37 spurious closure due to inadvertent ESAS.)
AB-FZ-6, CB-FA-1, CB-FA-2a, CB-FA-2d, CB-FA-2f, FH-FZ-1 Locally close MU-V-16A/B and Ensure MU-V-36/37 are open prior to closure AB-FZ-3 AB-FZ-4 1 Hr 86-9101191-001 (Uncontrolled RCS Injection)
Not required per RG 1.189 Rev.2.
Spurious ESAS causing overfill is not part of SSD success path.
Not Required.
EL-L-293 EL-L-89B RCS Pressure Control /
Makeup Pump Protection Prevent excessive RCS pressure and maintain MU pump minimum flow path (MU-V-16C/D spurious opening and MU-V-36/37 spurious closure due to inadvertent ESAS.)
CB-FA-2b, CB-FA-2c, CB-FA-2e, CB-FA-2g, CB-FA-3b, FH-FZ-5 Locally close MU-V-16C/D and Ensure MU-V-36/37 are open prior to closure AB-FZ-3 AB-FZ-6 1 Hr 86-9101191-001 (Uncontrolled RCS Injection)
Not required per RG 1.189 Rev.2.
Spurious ESAS causing overfill is not part of SSD success path.
Not Required.
EL-L-89B EL-L-292 RCS Pressure Control Prevent excessive RCS pressure (MU-V-217 spuriously opens OR MU-V-17 fails open)
AND MU-V-18 fails open CB-FA-2d, CB-FA-2e Locally close IA-V-1227 to fail closed MU-V-18 AB-FZ-4 1 Hr 86-9101191-001 (Uncontrolled RCS Injection)
C311-88-3271 C311-88-2057 EL-L-293 EFW Inventory CO-V-111A spuriously opens AND loss of IA fails open CO-V-7 & 8 AND CO-V-13 is not available CB-FA-1, FH-FZ-1, IB-FZ-3, IB-FZ4, IB-FZ-8 Locally CLOSE CO-V-8 and CO-V-108 TB-FA-1 1 Hr ECR 07-00702 NOTE 5 NOTE 5 EL-L-328A
ATTACHMENT 3-7A MANUAL ACTIONS REQUIRED FOR HOT SHUTDOWN IN APPENDIX R III.G.2 FIRE AREAS/ZONES (NOTE 5)
Page 8 FHAR Rev 27 Column Heading Notes (1) System Function:
The system function that the manual action supports.
(2) Condition which requires action (Equipment Failure):
This is the condition that requires compensatory action to achieve safe shutdown. Some actions are performed based on an observed equipment failure but some are proactive. Proactive actions are performed based on the condition described. The reason for the action (potential equipment failure) may be identified in parentheses.
(3) Applicable Fire Areas/Zones:
List all of the fire zones where this manual action (item 4) is required for a successful safe shutdown strategy.
(4) Action Required (Note 1):
This is a single action or group of actions, which are performed together if the condition exists. For example, cross tie DC buses is a single line item because these steps would be done together for a single common purpose.
(5) Location where Action is Performed:
List the Fire Areas (or Zones) where the actions are performed. A more detailed description may be identified in parentheses.
(6) Time Requirement:
Describes the maximum acceptable time for completion of the action. The starting time is the condition in column (2) unless otherwise noted.
(7) Time Requirement Basis:
References the technical basis or document for the time requirement.
(8) Exemption Approval/SER:
The NRC exemption or SER that approves the manual action.
(9) Exemption Request (Applicable Fire Areas/Zones):
The exemption request submitted to the NRC for approval of the manual action. The fire zones that are addressed by the exemption request are included in parenthesis.
(10) Emergency Light(s) Required for Action:
The lights required at the location where the action is required are identified. Pathway lighting to a component is not included.
Notes
- 1. For all MOVs, it is assumed that the breaker for the locally operated valve will be opened prior to valve operation. This is part of the required manual action.
- 2. Letdown is desired to maintain pressurizer level within the normal range, and enhance RCS inventory control. Letdown restoration and actions required to support letdown restoration (i.e., re-establishing NR or NS) are only required if (1) HPI cooling was used for decay heat removal or (2) Group 8 and Group 9 pressurizer heaters were lost and cannot be restored (including repairs Att. 3-7C).
- 3. The original basis of 30 minutes is based on the time required to support restoration of thermal barrier cooling. This function is no longer required. The NR system is only required for MU-P-1B and letdown cooling, however letdown restoration is not required for ISPH-FZ-1. Calculation 86-9101191-001 provides a time of at least 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to support restoration of makeup on a loss of all RCP seal cooling. Therefore, a minimum time of 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> exists to start MU-P-1B and thus provide MU-P-1B required cooling. However, 30 minutes will be used for conservatism per the existing exemption.
- 4. Additional conservatism was added when the RCP seals were replaced. 86-9101191-001 time is based on RCS losses with Westinghouse RCP Seals.
- 5. This table includes ALL actions that require an exemption. (i.e. Any action required outside of the control room to achieve hot shutdown for a fire in a III.G.2 fire area to maintain a safe shutdown success path). After NRC Reg.
Guide 1.189 Rev. 2 was issued, orange box manual actions do not require exemptions.
ATTACHMENT 3-7A MANUAL ACTIONS REQUIRED FOR HOT SHUTDOWN IN APPENDIX R III.G.2 FIRE AREAS/ZONES (NOTE 5)
Page 9 FHAR Rev 27 Exemption Request / Exemption Key Exemption Request NRC Exemption 5211-86-2124 (July 22, 1986) 5211-86-3333 (December 30, 1986) 5211-87-2021 (February 2, 1987),
5211-87-2033 (February 11, 1987),
5211-87-2047 (February 28, 1987),
5211-87-2059 (March 10, 1987) 5211-87-3066 (March 19, 1987) 5211-87-2175 (October 16, 1987)
C311-88-3225 (September 7, 1988)
C311-88-2057 (May 21, 1988),
C311-88-2010 (May 5, 1988)
C311-88-3271 (November 2, 1988) 5928-08-20023 (February 4, 2008)
TMI-09-008 (January 28, 2009)
NRC ADAMS ML090830708 (March 30, 2009)
NRC ADAMS ML090630134 (March 3, 2009)
NRC ADAMS ML100750093 (March 15, 2010)
NRC ADAMS ML101310113 (June 28, 2010)