I A CMS Energy Company August 29, 1997 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D~C 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT Thoma* t:. BordlaB Manager.
Licensing SPECIAL REPORT ON 1996 INSERVICE INSPECTION OF STEAM GENERA TOR TUBES Enclosed is a Special Report on the Palisades steam generator tube inservice inspection which was completed on November 28, 1996. Palisades Technical Specification 6.6.9b requires that this report be submitted to the Nuclear Regulatory Commision within 12 months following completion.
Our letter dated December 6, 1996, reported that four tubes were plugged in Steam Generator E-50A and no tubes were plugged in Steam Generator E-50B as a result of the inspection.
SUMMARY
OF COMMITMENTS This letter contains no new commitments and no revisions to existing commitments.
h-~rY~
Thomas C. Berdine Manager, Licensing cc Administrator, Region Ill, USNRC Project Manager, NRR,* USNRC NRG Resident Inspector - Palisades
[
1111m 1rn 1m1 11m !llD 1m11~fi l!fi 1 En~~~~~50163 -qj'Q02~;-:1
- . y*rf1 PDR ADOCK 05000255 '
.//
G PDR I
ri111saaes Nuc1ear nant
- 27180 Blue St,ar Memorial Highway
- Covliil, Ml 49043
- Tel: 616164 2913
- Fax: 616164 2490