Forwards Insp Repts 50-315/78-25 & 50-316/78-23 on 780710-0818 & Notice of Violation
ML17317A680
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 09/21/1978
From: Fiorelli G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Dolan J
INDIANA MICHIGAN POWER CO.
Shared Package
ML17317A681 List:
References
NUDOCS 7810270385
Download: ML17317A680 (2)


See also: IR 05000315/1978025

Text

CGio7 IPQFi)gw

~p,R RECII(

Wp

>>>>*4I'NITED

STATES

NUCLEAR

REGULATOR Y COMMISSION

REGION III

799 ROOSEVELT ROAD

GLEN ELLYN, ILLINOIS 60137

sEPP 8$

Dockec No. 50-315//8

Docket No. 50-316

American Electric Power Service

Corporation

Indiana

and Michigan Power

Company

ATTN:

Mr. John E. Dolan, Senior

Executive Vice President

Engineering

2 Broadway

New York, NY

10004

Gentlemen:

This refers to the inspection

conducted

by Mr. K. R. Baker of this

office on July 10, 12,

14,

17, 19-21,

24, 26-28; August 9-10,

14,

and 16-18,

1978, of activities at Donald

C.

Cook Nuclear Plant,

Units 1 and

2 authorized

by NRC Operating Licenses

No.

DPR-58 and

No. DPR-74 and to the discussion of our findings with Mr. D. Shaller

at the conclusion of the inspection.

The enclosed

copy of our inspection report identifies areas

examined during the inspection.

Within these areas,

the

inspection consisted of a selective

examination of procedures

and representative

records,

observations,

and interviews with

personnel.

During this inspection,

certain of your activities appeared

to be in noncompliance with NRC requirements,

as described

in the enclosed

Appendix A.

This notice is sent to you pursuant

to the provisions of

Section

2.201 of the NRC's "Rules of Practice," Part

2, Title

10,

Code of Pederal Regulations.

Section

2.201 requires

you

to submit to this office within twenty days of your receipt

of this notice

a written statement

or explanation in reply,

including for each item of noncompliance:

(1) corrective

action taken

and the results

achieved;

(2) corrective action

to be taken to avoid further noncompliance;

and (3) the date

when full compliance will be achieved.

Tn accordance

with Section'.790 of the NRC's "Rules of

Practice," Part

2, Title 10,

Code of Federal Regulations,

a

American Electric Power

Service Corporation

PEP Yl STs

copy of this letter, the enclosures,

and your response

to

this letter will be placed in the NRC's Public Document Room,

except

as follows. If the enclosures

contain information

,that you or your contractors believe to be proprietary,

you

must apply in writing to this office, within twenty days of

your receipt of this letter, to withhold such information

from public disclosure.

The application must include a full

statement of the reasons for which the information is con-

sidered proprietary,

and should be prepared

so that proprietary

information identified in the application is contained in an

enclosure to the application.

Re will gladly discuss

any questions

you have concerning this

inspection.

Sincerely,

Gaston Fiorelli9 Chief

Reactor Operations

and

Nuclear Support Branch

Enclosures:

l.

Appendix A, Notice

of Violation

2.

IE Inspection Rpts No.

50-. 315/78-25

and No.

50-316/78-23

cc w/encls:

D. V. Shaller, Plant Manager

Central Piles

Reproduction Unit NRC 20b

PDR

Local PDR

NSIC

TIC

Ronald Callen, Michigan Public

Service Commission

David D. Comey, Executive

Director, Citizens for a

Better Environment

OFFICEi

SURNAME~

RIII ~d/P)

-f

Baker/dec

RIII

Warnick

RIII

$h

acher

RIII

Fish

RI

Fiorell'i

oAT~ 9/19/78

NRC Form 3188 (RZZZ) (1-78) NRCM 0240

~U. S. GOVERNMENTPAINTINOOI'VICKI 1975

255.5IT