MONTHYEARHNP-11-001, Request for License Amendment, Measurement Uncertainty Recapture Power Uprate2011-04-28028 April 2011 Request for License Amendment, Measurement Uncertainty Recapture Power Uprate Project stage: Request ML11165A1862011-06-10010 June 2011 NRR E-mail Capture - FW: Acceptance Review for Harris 1 Measurment Uncertainity Recapture (MUR) TAC ME6169 Project stage: Acceptance Review ML11206A4962011-06-29029 June 2011 NRR E-mail Capture - Draft RAI Questions to Support Harris MUR Review (ME6169) Project stage: Draft RAI ML11181A0162011-07-0101 July 2011 Acceptance for Review of Measurement Uncertainty Recapture Power Uprate License Amendment Request Project stage: Acceptance Review ML11208C5092011-07-27027 July 2011 NRR E-mail Capture - Request for Additional Information Shearon Harris Unit 1, License Amendment Request Measurement Uncertainty Recapture Power Uprate Project stage: RAI ML1122001162011-07-29029 July 2011 NRR E-mail Capture - Shearon Harris Unit 1 - Measurement Uncertainty Recapture - MUR RAI (Cont/Vent) ME6169 Project stage: RAI ML11213A0002011-07-29029 July 2011 NRR E-mail Capture - Measurement Uncertainty Recapture Power Uprate - MUR RAI (HP-HPB)(ME6169) Project stage: RAI HNP-11-073, Response to Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate License Amendment Request2011-08-0303 August 2011 Response to Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate License Amendment Request Project stage: Response to RAI ML11213A1792011-08-0505 August 2011 Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate Project stage: RAI ML11214A0792011-08-0505 August 2011 Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate Project stage: RAI ML11214A1742011-08-0505 August 2011 Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate Project stage: RAI ML11222A1492011-08-0808 August 2011 NRR E-mail Capture - Measurement Uncertainty Recapture Power Uprate - MUR RAI (Mat)(ME6169) Project stage: RAI ML11222A1482011-08-0808 August 2011 NRR E-mail Capture - Measurement Uncertainty Recapture Power Uprate - MUR RAI (EMCB)(ME6169) Project stage: RAI HNP-11-076, Response to Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate License Amendment Request2011-08-15015 August 2011 Response to Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate License Amendment Request Project stage: Response to RAI HNP-11-034, Revision to Reactor Vessel Surveillance Capsule Withdrawal Schedule2011-08-16016 August 2011 Revision to Reactor Vessel Surveillance Capsule Withdrawal Schedule Project stage: Request HNP-11-079, Response to Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate License Amendment2011-08-31031 August 2011 Response to Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate License Amendment Project stage: Response to RAI ML11256A0262011-09-0606 September 2011 Response to Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate License Amendment Request Project stage: Response to RAI HNP-11-082, Response to Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate License Amendment Request2011-09-0707 September 2011 Response to Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate License Amendment Request Project stage: Response to RAI ML11271A1652011-09-28028 September 2011 NRR E-mail Capture - Additional MUR RAI (EEB)(ME6169) Project stage: RAI ML11272A0652011-09-28028 September 2011 NRR E-mail Capture - Additional MUR RAI (Emcb Part 2)(ME6169) Project stage: RAI ML11276A1872011-09-30030 September 2011 NRR E-mail Capture - MUR RAI (Cvib)( ME6169) Project stage: RAI ML1127300822011-09-30030 September 2011 Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate Project stage: RAI ML11276A1022011-10-14014 October 2011 Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate Project stage: RAI ML11276A1052011-10-14014 October 2011 Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate Project stage: RAI ML11278A1702011-10-14014 October 2011 Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate Project stage: RAI ML11276A1072011-10-18018 October 2011 Request for Additional Information Regarding Measurement Uncertainty Recapture Project stage: RAI HNP-11-094, Response to Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate (RAI 8)2011-10-20020 October 2011 Response to Request for Additional Information Regarding Measurement Uncertainty Recapture Power Uprate (RAI 8) Project stage: Response to RAI HNP-11-095, Request for License Amendment Measurement Uncertainty Recapture Power Uprate Response to Request for Additional Information (RAI 9)2011-10-21021 October 2011 Request for License Amendment Measurement Uncertainty Recapture Power Uprate Response to Request for Additional Information (RAI 9) Project stage: Response to RAI HNP-11-096, Request for License Amendment Measurement Uncertainty Recapture Power Uprate Response to Request for Additional Information (RAI 10)2011-10-28028 October 2011 Request for License Amendment Measurement Uncertainty Recapture Power Uprate Response to Request for Additional Information (RAI 10) Project stage: Response to RAI HNP-11-107, Supplement to Request for License Amendment Measurement Uncertainty Recapture Power Update2011-11-28028 November 2011 Supplement to Request for License Amendment Measurement Uncertainty Recapture Power Update Project stage: Supplement ML11340A0812011-12-0909 December 2011 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance HNP-11-097, Request for License Amendment - Measurement Uncertainty Recapture Power Uprate Supplemental Information2011-12-20020 December 2011 Request for License Amendment - Measurement Uncertainty Recapture Power Uprate Supplemental Information Project stage: Supplement ML11356A1592012-02-0808 February 2012 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML11356A1542012-02-0808 February 2012 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance HNP-12-002, Request for License Amendment Measurement Uncertainty Recapture Power Uprate Supplemental Information2012-02-0909 February 2012 Request for License Amendment Measurement Uncertainty Recapture Power Uprate Supplemental Information Project stage: Supplement HNP-12-044, Response to Request for Additional Information on License Amendment Request - Measurement Uncertainty Recapture Power Uprate2012-03-26026 March 2012 Response to Request for Additional Information on License Amendment Request - Measurement Uncertainty Recapture Power Uprate Project stage: Response to RAI HNP-12-065, CFR 50.46 Annual Report of Changes to LOCA Analyses2012-05-30030 May 2012 CFR 50.46 Annual Report of Changes to LOCA Analyses Project stage: Request ML11356A0962012-05-30030 May 2012 Issuance of License Amendment Regarding Measurement Uncertainty Recapture Power Uprate Project stage: Approval HNP-12-069, Request for License Amendment Measurement Uncertainty Recapture Power Uprate Comments Re Amendment 1392012-06-0505 June 2012 Request for License Amendment Measurement Uncertainty Recapture Power Uprate Comments Re Amendment 139 Project stage: Request ML12157A2812012-06-11011 June 2012 Correction to Issuance of Amendment No. 139 Measurement Uncertainty Recapture Power Uprate Project stage: Approval 2011-08-15
[Table View] |
Text
1 NRR-PMDAPEm Resource From:
Mozafari, Brenda Sent:
Wednesday, September 28, 2011 6:24 PM To:
Caves, John Cc:
Saba, Farideh
Subject:
Additional MUR RAI (EMCB part 2)( ME6169).docx Importance:
High
- John, By letter dated April 28, 2011 (Agencywide Documents Access and Management System Accession No. ML11124A180), Carolina Power & Light Company requested approval from the U.S. Nuclear Regulatory Commission (NRC) to increase the core thermal power level of Shearon Harris Nuclear Power Plant, Unit 1 from 2,900 megawatts thermal (MWt) to 2,948 MWt, an increase of approximately 1.66% over the present licensed power level and to change the power plant technical specifications accordingly.
The NRC staff has reviewed the supplemental information provided by the licensee in letter dated September 6, 2011. Based on our review of the response, the staff requests the following additional information:
RAI 1
In response to an NRC staff request for additional information (RAI), regarding the design code of record used in the evaluation of the reactor vessel internals (RVIs) to support the implementation of a measurement uncertainty recapture (MUR) power uprate at Shearon Harris Nuclear Power Plant, Unit 1 (HNP), it was stated in Reference 2 that the HNP RVIs are not American Society of Mechanical Engineers (ASME) Code internals.
As such, it was stated that no code of record is applicable to the original design and construction of the RVIs and that the structural integrity of the RVIs were originally using different design codes. Furthermore, it was stated that the 2004 Edition of the ASME Boiler and Pressure Vessel (B&PV) Code,Section III, Subsection NG, Core Support Structures, was used to evaluate the RVIs for acceptability at the conditions which will exist after MUR implementation.
Section 3.9.5.4 of the HNP Final Safety Analysis Report (FSAR) states that the intent of Subsection NG of the ASME B&PV Code was utilized in the evaluation of the RVIs, with respect to the allowable stresses used in the design basis analyses of the RVIs. The HNP FSAR also states that the allowable stress limits during the design basis accident are based on the 1973 draft of Subsection NG and the criteria for faulted conditions specified in the Code. Specifically, the FSAR cites the limits provided in Figure NG-3221-1 of the Code for the Normal and Upset Conditions, and NG-3224-1 of the Code for Emergency Conditions as those used in the evaluation of the RVIs. Faulted loading conditions were stated to have been evaluated in accordance with Appendix F of the Code.
Confirm that the stress limits cited in the HNP FSAR were utilized in the evaluation of the RVIs to support the proposed MUR power uprate at HNP and confirm that these limits will remain satisfied following MUR implementation. Additionally, please provide a technical justification regarding the use of the provisions in the 2004 Edition of the ASME B&PV Code,Section III, Subsection NG, in lieu of the design basis acceptance criteria cited in the HNP FSAR. This justification should include, but not be limited to, a confirmation that the criteria used in the design basis analyses of the RVIs (i.e., FSAR limits) have been reconciled to the criteria of the 2004 Edition of the ASME B&PV Code,Section III, Subsection NG.
RAI 2
In response to an NRC staff RAI, regarding the structural evaluation of the HNP baffle-former bolts to determine their adequacy at the proposed MUR power level, a qualitative discussion was provided which
2 compared the HNP baffle-former bolts to the baffle-former bolts at Almaraz Unit 2. As indicated in response to RAI 3 in Reference 2, the only loads used in the design of the HNP RVIs which are affected by the proposed MUR power uprate are those loads due to heat generation rates. It was stated that the HNP baffle-former bolts (a RVI component) were acceptable for operation at MUR conditions based on the fact that the Almaraz Unit 2 baffle-former bolts were structurally qualified under its current conditions, given the similarities in the geometries, operating parameters, design transients and heat generation rates between each facility.
Provide a quantitative summary of the information described above, which qualitatively compared the HNP and Almaraz Unit 2 baffle-former bolts, to demonstrate the structural qualification of these components at MUR conditions. Include a quantitative summary of the effects of the higher heat generation rates on the analysis of record for the baffle-former bolts, including the effects of the higher heat generation rates on the stresses and fatigue usage factors. Further, compare the expected stresses and fatigue usage factors in the baffle-former bolts to the HNP design basis acceptance criteria for these components such that an explicit determination, that the components will continue to meet their design basis requirements following MUR implementation, can be made.
It is requested that your RAI response be provided by October 21, 2011, as discussed with your staff on September 28, 2011. If more time is needed to respond to the RAl, your request for additional time should include a basis for the need for an extension.
Brenda L. Mozafari Senior Project Manager, NRR/DORL U.S. Nuclear Regulatory Commission 301-415-2020 email: brenda.mozafari@nrc.gov
Hearing Identifier:
NRR_PMDA Email Number:
158 Mail Envelope Properties (Brenda.Mozafari@nrc.gov20110928182400)
Subject:
Additional MUR RAI (EMCB part 2)( ME6169).docx Sent Date:
9/28/2011 6:24:12 PM Received Date:
9/28/2011 6:24:00 PM From:
Mozafari, Brenda Created By:
Brenda.Mozafari@nrc.gov Recipients:
"Saba, Farideh" <Farideh.Saba@nrc.gov>
Tracking Status: None "Caves, John" <john.caves@pgnmail.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 5314 9/28/2011 6:24:00 PM Options Priority:
High Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received:
ZZZ