ML100690308

From kanterella
Jump to navigation Jump to search

R. E. Ginna Nuclear Power Plant - Commitment Associated with Technical Specification LCO 3.4.14 RCS Pressure Isolation Valve (PIV) Leakeage
ML100690308
Person / Time
Site: Ginna Constellation icon.png
Issue date: 03/02/2010
From: Harding T
Constellation Energy Group, EDF Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML100690308 (3)


Text

Thomas L. Harding Director - Licensing R.E. Ginna Nuclear Power Plant, LLC 1503 Lake Road Ontario, New York 14519-9364 585.771.5219 Thomas.HardingJr@cengllc.com CENG

a joint venture of

.F*Oo*telation

.,eDF March,2, 2010 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

SUBJECT:

Document Control Desk R.E. Ginna Nuclear Power Plant Docket No. 50-244 Commitment Associated with Technical Specification LCO 3.4.14 RCS Pressure Isolation Valve (PiV) Leakage

Reference:

(1)

Letter from P. Swift, Ginna LLC, to NRC Document Control Desk,

Subject:

Fifth Ten-Year Inservice Test Program for Safety-Related Pumps and Valves, dated September 11, 2009.

On September 11, 2009 R.E. Ginna Nuclear Power Plant, LLC (Ginna LLC) submitted the fifth ten-year Inservice Test Program for safety-related pumps and valves (Reference 1). Within the referenced letter, Ginna LLC submitted a number of requests for relief from the provisions of 10 CFR 50.55a. One of the requests for relief, GR-0 1, was associated with reactor coolant system (RCS) pressure isolation valve (PIV) leakage testing.

As part of the staff review of the GR-0 1 relief request it was noted that the Ginna Technical Specification LCO (3.4.14) and associated Bases could be further clarified to address prior NRC approval of testing of specific check valve pairs as a single isolation valve. Attachment 1 provides the regulatory commitments associated with these clarifications.

If you should have any questions regarding this submittal, please contact Mr. Thomas Harding at (585) 771-5219 or Thomas.HardinaJracengllc.com.

Thomas Harding : List of Regulatory Commitments cc:

S. J. Collins, NRC D. V. Pickett, NRC Resident Inspector, NRC 6/LN1 C _-Oo9R (o (o NOOI NJr2(<

ATTACHMENT 1 List of Regulatory Commitments

ATTACHMENT 1 List of Regulatory Commitments The following table identifies those actions committed to by Ginna LLC in this document. Any other statements made in this licensing submittal are provided for informational purposes only and are not to be considered regulatory commitments. Please direct any questions you have in this matter to Mr. Thomas Harding at (585)771-5219.

COMMITMENT COMPLETION DATE The Technical Specification April 30, 2010 Bases for SR 3.4.14.2 will be clarified to clearly state that the NRC staff has previously approved testing check valve pairs as a single valve.

A footnote will be inserted in The next time the Technical Technical Specification SR Specification page is updated 3.4.14.2 to clarify testing check valve pairs as a single valve.