Finding | |
|---|---|
| Title | |
| Description | The inspectors identified a finding of very low safety significance and an associated non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensee's failure to maintain a containment "trash" gate closed and pinned while the area was unattended and the unit was in Mode 3. Specifically, the inspectors identified Trash Gate 3, as referenced by plant procedure DB-OP-03013, Containment Daily Inspection and Containment Closeout Inspection, as being unpinned and open on February 1, 2014, when it should have been closed and pinned. The finding was determined to be of more than minor significance because it was associated with the Mitigating Systems Cornerstone and directly impacted the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, failure to have the trash gate closed and pinned could allow debris generated during certain design basis accidents to degrade the capability of the Emergency Core Cooling System (ECCS) recirculation sump. The inspectors used Exhibit 2 Mitigating Systems Screening Questions for mitigating systems, structures, components and functionality. The finding screened out to be of very low safety significance because it was associated with a deficiency affecting the design or qualification of a mitigating system, structure, or component that did not result in a loss of operability or functionality. Specifically, the licensee had performed an analysis that concluded that the ECCS recirculation sump remained operable even with assuming additional debris reaching the upper sump screening in a post-accident environment. This finding has a cross-cutting aspect in the area of Problem Identification and Resolution (PI&R) because the licensee's corrective actions for a previous issue were less than fully effective; the inspectors identified exactly the same issue under very similar circumstances in 2011 (see NCV 05000346/2011002-02 for additional details). |
| Site: | Davis Besse |
|---|---|
| Report | IR 05000346/2014002 Section 1R20 |
| Date counted | Mar 31, 2014 (2014Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.2 |
| Inspectors (proximate) | D Kimble J Cameron J Neurauter J Rutkowski M Marshfield M Mitchell T Briley |
| Violation of: | 10 CFR 50 Appendix B Criterion V |
| CCA | P.3, Resolution |
| INPO aspect | PI.3 |
| ' | |
Finding - Davis Besse - IR 05000346/2014002 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Davis Besse) @ 2014Q1
Self-Identified List (Davis Besse)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||