Finding | |
|---|---|
| Title | Failure to Adequately Evaluate the Required Minimum Level in the Borated Water Storage Tank |
| Description | The inspectors identified a noncited violation of 10 CFR 50 Appendix B Criterion III for failure to verify and check the adequacy of design by performance of design reviews, alternate calculations, or a suitable testing program. Specifically, the licensee did not adequately evaluate the required minimum level in the Borated Water Storage Tank to ensure adequate net positive suction head for Emergency Core Cooling System pumps and prevent gas entrainment due to vortex formation. The licensee performed an immediate operability evaluation and concluded that there was sufficient margin in the level to maintain operability. The licensee entered this issue into their corrective action program as Condition Report CR-ANO-1-2011-1407 and CR-ANO-1-2011-1440. The failure to adequately evaluate the minimum level in the Borated Water Storage Tanks to ensure adequate net positive suction head for Emergency Core Cooling System pumps and prevent vortex formation is a performance deficiency. The performance deficiency is more than minor because it is associated with the design control attribute of the Mitigating Systems cornerstone and adversely affects the objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the licensee did not adequately ensure that the design of the Borated Water Storage Tank was sufficient to avoid loss of net positive suction head and prevent air entrainment in the Emergency Core Cooling System pumps. The inspector performed a Phase 1 screening, in accordance with Inspection Manual Chapter 0609, Attachment 4, Phase 1 Initial Screening and Characterization of Findings, and determined that the finding was of very low safety significance (Green), because the finding was confirmed not to result in a loss of operability. The finding was determined to have no cross-cutting aspect because the performance deficiency occurred in 2004, and is not indicative of current plant performance. |
| Site: | Arkansas Nuclear |
|---|---|
| Report | IR 05000313/2011004 Section 4OA5 |
| Date counted | Sep 30, 2011 (2011Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | |
| Inspectors (proximate) | A Sanchez J Rotton K Clayton L Ricketson R Azua R Kumana W Schaup |
| INPO aspect | |
| ' | |
Finding - Arkansas Nuclear - IR 05000313/2011004 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Arkansas Nuclear) @ 2011Q3
Self-Identified List (Arkansas Nuclear)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||