Finding | |
|---|---|
| Title | Failure to Ensure that 480V System Voltages do not Exceed Equipment Ratings |
| Description | The inspectors identified a finding of very low safety significance and associated NCV of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the licensees failure to ensure that voltages on the 480V system do not exceed equipment ratings. Specifically, the licensee increased the output voltage of the supply transformers to the 480V safety-related buses by 2.5 percent, but failed to ensure the resulting voltages would not exceed equipment ratings when the system is powered from the station power transformer or emergency diesel generator. The licensee entered this finding into their Correction Action Program and verified the operability of the affected equipment. The performance deficiency was determined to be more than minor, because it impacted the Design Control attribute of the Reactor Safety, Mitigating Systems Cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the licensee failed to verify or check the voltage increase on the 480V system to ensure the maximum allowable voltage would not exceed equipment ratings. The inspectors determined the finding was of very low safety significance (Green) because the affected SSCs maintained their operability and functionality. The inspectors did not identify a cross-cutting aspect associated with this finding, because the finding was not representative of the licensees present performance. |
| Site: | Palisades |
|---|---|
| Report | IR 05000255/2014008 Section 1R21 |
| Date counted | Dec 31, 2014 (2014Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | A Stone C Baron C Brown C Zoia H Leake J Corujo-Sandin L Rodriguez S Sheldon |
| Violation of: | 10 CFR 50 Appendix B Criterion III, Design Control |
| INPO aspect | |
| ' | |
Finding - Palisades - IR 05000255/2014008 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Palisades) @ 2014Q4
Self-Identified List (Palisades)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||