From: Silko, Thomas B. [1]
Sent: Thursday, August 11, 2016 11:26 AM To: Parrott, Jack <Jack.Parrott@nrc.gov>
Subject:
[External_Sender] Response to NRC Questions dated 7 16 Jack, Based upon our conversation on Wednesday 8/3/16, VY agreed to provide a copy of the Part 61 analysis which was used to identify the radionuclide concentrations on the Torus water. Accordingly, please find attached a copy of the Part 61 report from GEL Laboratories, dated April 26, 2016.
In response to the Staffs second question, VY and the NRC discussed the process for sampling of material prior to making radioactive shipments.
VY procedure V
-EN-RW-102, Shipment of Radioactive Material, requires an isotopic be performed to ensure the material is appropriately classified per 10 CFR 61.55 requirements.
The isotopic is performed on a sample of the material (in this case a water sample) prior to completing the shipment manifest.
As such, VY is committed to sampling water prior to shipment to satisfy the requirements of 10CFR61.55.
In addition, Vermont Yankee commits to the following:
Vermont Yankee will perform a representative sample prior to each shipment of water and will confirm that the radionuclide concentrations result in doses that are equal to or less than, the doses delineated within the Summary of Project Alternative Disposal Dose Results, in our June 28, 2016 letter (BVY 16
-021; ADAMS Accession No. ML16182A035).
For example, the above could be satisfied in the following manner:
A representative sample is taken prior to a shipment and the radionuclide concentrations are verified to be equal to or less than those concentrations shown on the Data Input Worksheet, of our June 28, 2016 letter.
An alternative method to be used, such as when a radionuclide is identified as being slightly above the concentrations (while others may be lower), then sample radionuclide concentrations would be input into the Site Specific Dose Assessment Methodology (SSDA) used in our June 28, 2016 letter and the dose consequences verified to be equal to or less than that delineated within the Summary of Project Alternative Disposal Dose Results.
Please let me know if there are any further questions.
Thank You.
Tom Silko (802) 451
-3166
April 26, 2016
Mr. Mark Vandale Entergy Nuclear Operations, Inc., VY 530 Governor Hunt Road PO Box 250 Vernon, Vermont 05354
Re: Vermont Yankee Part 61 Work Order: 395827
Dear Mr. Vandale:
GEL Laboratories, LLC GEL appreciates the opportunity to provide the enclosed analytical results for the samples we received on April 21, 2016. This original data report has been prepared and reviewed in accordance with GEL's standard operating procedures.
Our policy is to provide high quality, personalized analytical services to enable you to meet your analytical needs on time every time. We trust that you will find everything in order and to your satisfaction. If you have any questions, please do not hesitate to call me at 843 556-8171, ext. 4504.
Sincerely, PM_SIGN_HERE Erin Trent Project Manager Purchase Order: 10287833 Enclosures Table of Contents Case Narrative......................................................................................1 Chain of Custody..................................................................................3
Laboratory Certifications......................................................................7
Radiological Analysis...........................................................................9 Case Narrative............................................................................10
Sample Data Summary...............................................................33
Quality Control Summary..........................................................37 Case Narrative Page 1 of 49 Case Narrative for Vermont Yankee, Entergy Nuclear Operations Inc.
SDG: 395827 April 26, 2016 Laboratory Identification:
GEL Laboratories LLC
2040 Savage Road
Charleston, South Carolina 29407
843 556-8171 Summary Sample Receipt The sample arrived at GEL Laboratories LLC, Charleston, South Carolina on April 21, 2016 for analysis. Chain of Custody form did not contain a relinquished signature. All sample containers arrived without
any visible signs of tampering or breakage. There are no additional comments concerning sample receipt.
Sample Identification The laboratory received the following sample:
Laboratory IDClient ID395827001 Torus Water #2 Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC GEL Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and
reduction are contained in the analytical case narratives in the enclosed data package.
Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, and data from the following fractions: Radiochemistry.
PM_SIGN_HERE Erin Trent
Project Manager Page 2 of 49 Chain of Custody Page 3 of 49 Page 4 of 49 Page 5 of 49 Page 6 of 49 Laboratory Certifications Page 7 of 49 StateCertification AlaskaArkansasCLIACalifornia ColoradoConnecticut DelawareDoD ELAP/ ISO17025 A2LA Florida NELAP Foreign Soils Permit GeorgiaGeorgia SDWA HawaiiIdaho Chemistry Idaho Radiochemistry Illinois NELAP IndianaKansas NELAP Kentucky SDWA Kentucky Wastewater Louisiana NELAP Louisiana SDWA MarylandMassachusetts MichiganMississippi NebraskaNevadaNew Hampshire NELAP New Jersey NELAP New Mexico New York NELAP North Carolina North Carolina SDWA North Dakota OklahomaPennsylvania NELAP S.Carolina Radchem South Carolina Chemistry Tennessee Texas NELAP Utah NELAP VermontVirginia NELAP Washington West Virginia UST-011088-065142D0904046 2940 SC00012PH-0169SC000122567.01E87156P330-15-00283, P330-15-00253 SC00012967SC00012SC00012SC00012200029C-SC-01E-10332901299012903046 (AI33904)
LA160006270M-SC0129976SC00012NE-OS-26-13 SC000122016-1 205415SC002SC000121150123345709R-158990468-004851012000210120001TN 02934T104704235-16-11 SC000122016-20 VT87156460202C780997404List of current GEL Certifications as of 26 April 2016 Page 8 of 49 Radiological Analysis Page 9 of 49 Case Narrative Page 10 of 49 Radiochemistry Technical Case Narrative Vermont Yankee, Entergy Nuclear Operations Inc. NTRG SDG #: 395827
Method/Analysis Information Product:
Alphaspec Pu242, Liquid Analytical Method:
DOE EML HASL-300, Pu-11-RC Modified Analytical Batch Number:
1562629Sample ID Client ID 395827001 Torus Water #2 1203535939 Method Blank MB 1203535941 Laboratory Control Sample LCS 1203535940 395827001Torus Water #2 Sample Duplicate DUP
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with
GL-RAD-A-011 REV# 26.
Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Standards Information
Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
QC Information
All of the QC samples met the required acceptance limits.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Page 11 of 49 Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Sample Re-prep/Re-analysis
None of the samples in this sample set required reprep or reanalysis.
Recounts Sample 395827001 Torus Water #2 was recounted due to a suspected false positive. The recount is reported.
Miscellaneous Information:
Data Exception DER Documentation
Data exception reports are generated to document any procedural anomalies that may deviate from referenced
SOP or contractual documents. A data exception report DER was not generated for this SDG.
Manual Integration
No manual integrations were performed on data in this batch.
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
Additional comments were not required for this sample set.
Qualifier Information
Manual qualifiers were not required.
Method/Analysis Information Product:
Alphaspec Am241, Cm, Liquid Analytical Method:
DOE EML HASL-300, Am-05-RC Modified Analytical Batch Number:
1562630Sample ID Client ID 395827001 Torus Water #2 1203535946 Method Blank MB 1203535948 Laboratory Control Sample LCS 1203535947 395827001Torus Water #2 Sample Duplicate DUP
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with Page 12 of 49 GL-RAD-A-011 REV# 26.
Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Standards Information
Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
QC Information
All of the QC samples met the required acceptance limits.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Sample Re-prep/Re-analysis
None of the samples in this sample set required reprep or reanalysis.
Recounts None of the samples in this sample set were recounted.
Miscellaneous Information:
Data Exception DER Documentation
Data exception reports are generated to document any procedural anomalies that may deviate from referenced
SOP or contractual documents. A data exception report DER was not generated for this SDG.
Manual Integration
No manual integrations were performed on data in this batch.
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
Additional comments were not required for this sample set.
Qualifier Information
Manual qualifiers were not required.
Page 13 of 49 Method/Analysis Information Product:
Alphaspec Np, Liquid Analytical Method:
ASTM C 1476-00 Modified Analytical Batch Number:
1562631Sample ID Client ID 395827001 Torus Water #2 1203535949 Method Blank MB 1203535951 Laboratory Control Sample LCS 1203535950 395827001Torus Water #2 Sample Duplicate DUP
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with
GL-RAD-A-032 REV# 20.
Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Standards Information
Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
QC Information
All of the QC samples met the required acceptance limits.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Sample Re-prep/Re-analysis Page 14 of 49 None of the samples in this sample set required reprep or reanalysis.
Recounts None of the samples in this sample set were recounted.
Miscellaneous Information:
Data Exception DER Documentation
Data exception reports are generated to document any procedural anomalies that may deviate from referenced
SOP or contractual documents. A data exception report DER was not generated for this SDG.
Manual Integration
No manual integrations were performed on data in this batch.
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
Additional comments were not required for this sample set.
Qualifier Information
Manual qualifiers were not required.
Method/Analysis Information Product:
Gammaspec, Gamma, Liquid Standard List Analytical Method:
EPA 901.1 Analytical Batch Number:
1561698Sample ID Client ID 395827001 Torus Water #2 1203533384 Method Blank MB 1203533386 Laboratory Control Sample LCS 1203533385 395827001Torus Water #2 Sample Duplicate DUP
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with
GL-RAD-A-013 REV# 25.
Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Page 15 of 49 Standards Information
Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
QC Information
All of the QC samples meet the required acceptance limits with the following exceptions: Refer to Data
Exception Report DER.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Sample Re-prep/Re-analysis
None of the samples in this sample set required reprep or reanalysis.
Recounts None of the samples in this sample set were recounted.
Miscellaneous Information:
Data Exception DER Documentation
Data exception reports are generated to document any procedural anomalies that may deviate from referenced
SOP or contractual documents. The following DER was generated for this SDG: DER 1513408 was generated
due to RDL less than MDA. The following RDLs in sample 395827001 were not achieved: Cs-134, Fe-59,
Nb-95 and Zr-95. The following RDLs in DUP 1203533385 were not achieved: Cs-134, Fe-59, Nb-95 and
Zr-95. Samples did not meet the required detection limit due to high sample activity. Reporting results.
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
Additional comments were not required for this sample set.
Qualifier Information
Manual qualifiers were not required.
Method/Analysis Information Page 16 of 49 Product:
Gamma I129, Liquid Analytical Method:
DOE EML HASL-300,I-01 Modified Analytical Batch Number:
1562602Sample ID Client ID 395827001 Torus Water #2 1203535843 Method Blank MB 1203535846 Laboratory Control Sample LCS 1203535844 395827001Torus Water #2 Sample Duplicate DUP 1203535845 395827001Torus Water #2 Matrix Spike MS The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with
GL-RAD-A-006 REV# 21.
Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Standards Information
Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
QC Information
All of the QC samples met the required acceptance limits.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Sample Re-prep/Re-analysis
None of the samples in this sample set required reprep or reanalysis.
Recounts None of the samples in this sample set were recounted.
Page 17 of 49 Miscellaneous Information:
Data Exception DER Documentation
Data exception reports are generated to document any procedural anomalies that may deviate from referenced
SOP or contractual documents. A data exception report DER was not generated for this SDG.
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
Additional comments were not required for this sample set.
Qualifier Information
Manual qualifiers were not required.
Method/Analysis Information Product:
Gamma Ni59, Liquid Analytical Method:
DOE RESL Ni-1 Analytical Batch Number:
1562693Sample ID Client ID 395827001 Torus Water #2 1203536149 Method Blank MB 1203536151 Laboratory Control Sample LCS 1203536150 395827001Torus Water #2 Sample Duplicate DUP
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with
GL-RAD-A-022 REV# 17.
Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Standards Information
Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Page 18 of 49 Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
QC Information
All of the QC samples met the required acceptance limits.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Sample Re-prep/Re-analysis
None of the samples in this sample set required reprep or reanalysis.
Chemical Recoveries
All chemical recoveries meet the required acceptance limits for this sample set.
Recounts None of the samples in this sample set were recounted.
Miscellaneous Information:
Data Exception DER Documentation
Data exception reports are generated to document any procedural anomalies that may deviate from referenced
SOP or contractual documents. A data exception report DER was not generated for this SDG.
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
Additional comments were not required for this sample set.
Qualifier Information
Manual qualifiers were not required.
Method/Analysis Information Product:
GFPC, Sr89&Sr90, Liquid Analytical Method:
EPA 905.0 Modified/DOE RP501 Rev. 1 Modified Analytical Batch Number:
1562716Sample ID Client ID Page 19 of 49 395827001 Torus Water #2 1203536197 Method Blank MB 1203536199 Laboratory Control Sample LCS 1203536198 395827001Torus Water #2 Sample Duplicate DUP The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with
GL-RAD-A-004 REV# 17.
Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Standards Information
Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
QC Information
All of the QC samples met the required acceptance limits.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Sample Re-prep/Re-analysis
None of the samples in this sample set required reprep or reanalysis.
Chemical Recoveries
All chemical recoveries meet the required acceptance limits for this sample set.
Recounts Sample 1203536198 Torus Water #2DUP was recounted due to a suspected total strontium false positive. The
recount is reported.
Miscellaneous Information:
Data Exception DER Documentation
Data exception reports are generated to document any procedural anomalies that may deviate from referenced
SOP or contractual documents. A data exception report DER was not generated for this SDG.
Page 20 of 49
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
Additional comments were not required for this sample set.
Qualifier Information
Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Pu241, Liquid Analytical Method:
DOE EML HASL-300, Pu-11-RC Modified Analytical Batch Number:
1562632Sample ID Client ID 395827001 Torus Water #2 1203535952 Method Blank MB 1203535954 Laboratory Control Sample LCS 1203535953 395827001Torus Water #2 Sample Duplicate DUP
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with
GL-RAD-A-035 REV# 16.
Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Standards Information
Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
Page 21 of 49 QC Information All of the QC samples met the required acceptance limits.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Sample Re-prep/Re-analysis
None of the samples in this sample set required reprep or reanalysis.
Recounts Samples 1203535952 MB, 1203535953 Torus Water #2DUP and 395827001 Torus Water #2 were
recounted due to high MDCs. The recounts are reported.
Miscellaneous Information:
Data Exception DER Documentation
Data exception reports are generated to document any procedural anomalies that may deviate from referenced
SOP or contractual documents. A data exception report DER was not generated for this SDG.
Manual Integration
No manual integrations were performed on data in this batch.
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
Additional comments were not required for this sample set.
Qualifier Information
Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Fe55, Liquid Analytical Method:
DOE RESL Fe-1, Modified Analytical Batch Number:
1562672Sample ID Client ID 395827001 Torus Water #2 1203536076 Method Blank MB 1203536078 Laboratory Control Sample LCS 1203536077 395827001Torus Water #2 Sample Duplicate DUP Page 22 of 49 The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with
GL-RAD-A-040 REV# 12.
Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Standards Information
Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
QC Information
All of the QC samples met the required acceptance limits.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Sample Re-prep/Re-analysis
None of the samples in this sample set required reprep or reanalysis.
Recounts None of the samples in this sample set were recounted.
Miscellaneous Information:
Data Exception DER Documentation
Data exception reports are generated to document any procedural anomalies that may deviate from referenced
SOP or contractual documents. A data exception report DER was not generated for this SDG.
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
Additional comments were not required for this sample set.
Page 23 of 49 Qualifier Information Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Ni63, Liquid Analytical Method:
DOE RESL Ni-1, Modified Analytical Batch Number:
1562678Sample ID Client ID 395827001 Torus Water #2 1203536092 Method Blank MB 1203536094 Laboratory Control Sample LCS 1203536093 395827001Torus Water #2 Sample Duplicate DUP
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with
GL-RAD-A-022 REV# 17.
Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Standards Information
Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
QC Information
All of the QC samples met the required acceptance limits.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Page 24 of 49 Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Sample Re-prep/Re-analysis
None of the samples in this sample set required reprep or reanalysis.
Recounts None of the samples in this sample set were recounted.
Miscellaneous Information:
Data Exception DER Documentation
Data exception reports are generated to document any procedural anomalies that may deviate from referenced
SOP or contractual documents. A data exception report DER was not generated for this SDG.
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
Additional comments were not required for this sample set.
Qualifier Information
Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint Tc99, Liquid Analytical Method:
DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number:
1562683Sample ID Client ID 395827001 Torus Water #2 1203536111 Method Blank MB 1203536113 Laboratory Control Sample LCS 1203536112 395827001Torus Water #2 Sample Duplicate DUP
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with
GL-RAD-A-059 REV# 4.
Page 25 of 49 Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Standards Information
Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
QC Information
All of the QC samples meet the required acceptance limits with the following exceptions: Refer to Data
Exception Report DER.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Sample Re-prep/Re-analysis
None of the samples in this sample set required reprep or reanalysis.
Recounts Samples were recounted due to high relative percent difference/relative error ratio. The recount results are
similar to the original results. Original results are reported.
Miscellaneous Information:
Data Exception DER Documentation
A data exception report DER 1517546 was generated for samples in this SDG/batch. DER 1517546 was
generated due to Failed RPD for DUP. 1. Sample 395827001 and duplicate 1203536112 do not meet the relative
percent difference requirement or the relative error ratio requirement due to the matrix of the sample. 1.
Reporting results.
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
Additional comments were not required for this sample set.
Qualifier Information
Manual qualifiers were not required.
Page 26 of 49 Method/Analysis Information Product:
LSC, Tritium Dist, Liquid Analytical Method:
EPA 906.0 Modified Analytical Batch Number:
1562687Sample ID Client ID 395827001 Torus Water #2 1203536126 Method Blank MB 1203536129 Laboratory Control Sample LCS 1203536127 395827001Torus Water #2 Sample Duplicate DUP 1203536128 395827001Torus Water #2 Matrix Spike MS The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with
GL-RAD-A-002 REV# 21.
Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Standards Information
Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
QC Information
All of the QC samples meet the required acceptance limits with the following exceptions: The Matrix Spike
1203536128 Torus Water #2MS did not meet recovery requirements due to the sample activity being greater
than five times the spiked nominal concentration.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Page 27 of 49 Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Recounts Sample 1203536129 LCS was recounted due to low recovery. The recount is reported.
Miscellaneous Information:
Data Exception DER Documentation
Data exception reports are generated to document any procedural anomalies that may deviate from referenced
SOP or contractual documents. A data exception report DER was not generated for this SDG.
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
The matrix spike, 1203536128 Torus Water #2MS, aliquot was reduced to conserve sample volume.
Qualifier Information
Manual qualifiers were not required.
Method/Analysis Information Product:
Liquid Scint C14, Liquid Analytical Method:
EPA EERF C-01 Modified Analytical Batch Number:
1562691Sample ID Client ID 395827001 Torus Water #2 1203536141 Method Blank MB 1203536144 Laboratory Control Sample LCS 1203536142 395827001Torus Water #2 Sample Duplicate DUP 1203536143 395827001Torus Water #2 Matrix Spike MS
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference
Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as
Standard Operating Procedure SOP. The data discussed in this narrative has been analyzed in accordance with
GL-RAD-A-003 REV# 15.
Calibration Information:
Calibration Information
All initial and continuing calibration requirements have been met.
Page 28 of 49 Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used
before the expiration dates.
Sample Geometry
All counting sources were prepared in the same geometry as the calibration standards.
Quality Control QC Information:
Blank Information
The blank volume is representative of the sample volume in this batch.
QC Information
All of the QC samples met the required acceptance limits.
Designated QC
The following sample was used for QC: 395827001 Torus Water #2.
Technical Information:
Holding Time
All sample procedures for this sample set were performed within the required holding time.
Sample Re-prep/Re-analysis
None of the samples in this sample set required reprep or reanalysis.
Recounts None of the samples in this sample set were recounted.
Miscellaneous Information:
Data Exception DER Documentation
Data exception reports are generated to document any procedural anomalies that may deviate from referenced
SOP or contractual documents. A data exception report DER was not generated for this SDG.
Manual Integration
No manual integrations were performed on data in this batch.
Sample-Specific MDA/MDC
The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.
Additional Comments
Additional comments were not required for this sample set.
Qualifier Information
Manual qualifiers were not required.
Certification Statement
Where the analytical method has been performed under NELAP certification, the analysis has met all of the
requirements of the NELAC standard unless otherwise noted in the analytical case narrative.
Page 29 of 49 GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com VERM001 Vermont Yankee, Entergy Nuclear Operations Inc.
Client SDG: 395827 GEL Work Order: 395827 Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Erin Trent.
Reviewed by Sample(s) Contained within this report:
395827001Lab Sample IDClient Sample ID Sample Description Torus Water #2 N/ACollected 04/11/2016 09:10 Signature:
Name:Date:Title:05 MAY 2016 Theresa Austin Group Leader Page 30 of 49 1513408DER Report No.:
1Revision No.:
Spencer Collins Originator's Name:
22-APR-16 Shenise Gerideau
Data Validator/Group Leader:
22-APR-16 Instrument Type:
Client Code:
Quality Criteria:
GAMMA SPECTROMETER Specifications VERMType:ProcessDivision:
Radiochemistry Mo.Day Yr.
22-APR-16 GEL Laboratories LLC Form GEL-DER DATA EXCEPTION REPORT DER Disposition:
Samples did not meet the required detection limit due to high sample
activity. Reporting results.
Specification and Requirements
Exception
Description:
The following RDLs in sample 395827001 were not achieved: Cs-134,
Fe-59, Nb-95 and Zr-95.
The following RDLs in DUP 1203533385 were not achieved: Cs-134,
Fe-59, Nb-95 and Zr-95.
Application Issues:
RDL less than MDA Batch ID:
1561698Test / Method:
EPA 901.1 LiquidMatrix Type:
See Below
Sample Numbers:Potentially affected work order(s)(SDG):395827 Page 31 of 49 1517546DER Report No.:
2Revision No.:
Elizabeth Krouse Originator's Name:
05-MAY-16 Lyndsey Pace
Data Validator/Group Leader:
05-MAY-16 Instrument Type:
Client Code:
Quality Criteria:
LSCSpecifications VERMType:ProcessDivision:
Radiochemistry Mo.Day Yr.
05-MAY-16 GEL Laboratories LLC Form GEL-DER DATA EXCEPTION REPORT DER Disposition:
- 1. Reporting results.
Specification and Requirements
Exception
Description:
- 1. Sample 395827001 and duplicate 1203536112 do not meet the relative
percent difference requirement or the relative error ratio requirement due
to the matrix of the sample.
Application Issues:
Failed RPD for DUP Batch ID:
1562683Test / Method:
DOE EML HASL-300, Tc-02-RC ModifiedLiquidMatrix Type:
See Below
Sample Numbers:Potentially affected work order(s)(SDG):395827 Page 32 of 49 Sample Data Summary Page 33 of 49 GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Note(s):1. Calculated MDAs are a-posteriori values at the 95% confidence level.
- 2. Activity is reported on a dry weight basis unless otherwise indicated in the case narrativeand is decay corrected to the
sample collect date.
- 3. Results are statistically positive at the 95% confidence level. (activity is greater than or equal to the two sigma uncertainty)
U Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.
10 CFR Part 50/61 Certificate of Analysis GEL Sample ID:
Matrix:Geometry Received:
Client:Collect Date:
Receive Date:
Client Sample ID:
395827001 WaterVermont Yankee, Entergy Nuclear Operatio April 11, 2016 April 21, 2016 Torus Water #2 Report Date:
May 05, 2016AnalyteRun Date ActivityMDAQualifier 2 SigmaUncertainty RL Alpha Spec Gamma Spec H-3C-14Fe-55Ni-63Sr-89Sr-90Tc-99Pu-241Np-237Pu-238Pu-239/240 Pu-242Am-241Cm-242Cm-243/244 Be-7Na-22K-40Cr-51Mn-54Fe-59Co-56Co-57 Co-58Co-60Ni-59Zn-65Y-88Zr-95Nb-94Nb-95Ru-106Ag-110mSn-11304/29/1605/03/1604/28/1604/29/1605/02/1605/02/1605/03/1605/04/1604/30/1605/02/1605/02/1605/02/1604/30/1604/30/1604/30/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/16 04/21/1604/21/1604/28/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/16 1.70E+06 1.49E+01 9.53E+01 7.94E+02 1.08E+00 3.31E-01 3.89E+03 7.38E+00
-1.66E-01 1.96E-02
4.85E-02 1.91E-01 4.31E-02 0.00E+00
-5.11E-03 3.92E+01
6.07E+00 1.14E+01 3.07E+01 4.71E+02 2.87E+01 7.28E+00 3.24E+00
9.00E+01 2.07E+04 5.85E+00 1.95E+03
-1.32E+00 2.37E+01
-7.62E+00 6.97E+00 3.19E+01
-4.46E+00 9.02E+00 3.33E+04 2.41E+01 6.05E+01 7.12E+01 1.29E+00 9.80E-01 9.37E+01 1.13E+01 3.14E-01 2.14E-01 2.13E-01 2.99E-01 7.39E-02 4.66E-02 4.41E-02 9.40E+01 7.93E+00 5.16E+01 9.82E+01 2.43E+01 3.55E+01 1.52E+01 7.66E+00
2.06E+01 7.10E+01 6.40E+00 6.85E+01 5.08E+00 2.40E+01 1.13E+01 1.34E+01 1.04E+02 2.14E+01 1.28E+01 1.75E+03 4.08E+01 8.07E+01 7.04E+01 2.18E+00 2.66E+00 4.26E+01 1.91E+01 9.68E-01 4.50E-01 3.86E-01 4.10E-01 6.47E-02 6.93E-02 1.02E-01 1.59E+02 1.35E+01 8.56E+01 1.69E+02 2.38E+01 6.01E+01 2.61E+01 1.28E+01
2.46E+01 1.26E+01 1.01E+01 5.59E+01 8.67E+00 4.17E+01 1.84E+01 2.31E+01 1.72E+02 3.65E+01 2.19E+01 2.00E+03 5.00E+01 1.10E+02 5.30E+02 2.30E+01 3.50E+00 5.00E+01 2.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 3.00E+01 1.50E+01 1.50E+01 2.00E+01 3.00E+01 3.00E+01
1.50E+01 3U33U U3UUUUUUUUUUUU3UUU33U3U UUUUUU12pCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/L pCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LUnitsPage 34 of 49 GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Note(s):1. Calculated MDAs are a-posteriori values at the 95% confidence level.
- 2. Activity is reported on a dry weight basis unless otherwise indicated in the case narrativeand is decay corrected to the
sample collect date.
- 3. Results are statistically positive at the 95% confidence level. (activity is greater than or equal to the two sigma uncertainty)
U Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.
10 CFR Part 50/61 Certificate of Analysis GEL Sample ID:
Matrix:Geometry Received:
Client:Collect Date:
Receive Date:
Client Sample ID:
395827001 WaterVermont Yankee, Entergy Nuclear Operatio April 11, 2016 April 21, 2016 Torus Water #2 Report Date:
May 05, 2016AnalyteRun Date ActivityMDAQualifier 2 SigmaUncertainty RLSb-124Sb-125I-129Cs-134Cs-136Cs-137Ba-133Ba-140Ce-139Ce-141Ce-144Nd-147Pm-144Pm-146Eu-152Eu-154Eu-155Ir-192Hg-203Tl-208Pb-210Pb-212Pb-214 Bi-212Bi-214Ra-228Ac-228Th-234U-235U-238Np-239Am-24104/21/1604/21/1604/27/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/16 04/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/1604/21/16 -3.65E+00 8.30E+00
-3.73E-02
-1.30E+01 5.93E+00
1.13E+03
-7.26E+00
-1.12E+01
-8.99E+00
-9.12E+00 3.42E+01
-8.63E+01 1.21E+00
4.46E+00 1.35E+01 1.78E+01 1.43E+01
-2.79E+00 8.62E+00 8.75E+00 9.04E+02
-1.47E+00
-6.77E+00
-6.90E+01
-1.64E+00 4.22E+01
4.22E+01 3.77E+02
-3.80E+01 3.77E+02 7.01E+01
-2.43E+01 1.09E+01
2.74E+01 8.59E-01 1.47E+01 3.45E+01 2.43E+01 1.32E+01 6.57E+01 8.66E+00 1.67E+01 5.98E+01 1.33E+02 1.14E+01 1.29E+01 2.86E+01 2.25E+01 3.04E+01 9.96E+00 1.07E+01 1.20E+01 1.07E+03 1.92E+01 2.15E+01
1.77E+02 2.21E+01 6.30E+01 6.30E+01 3.56E+02 5.95E+01 3.56E+02 7.43E+01 4.16E+01 1.88E+01 4.64E+01 1.51E+00 2.52E+01 5.84E+01 2.06E+01 2.09E+01 1.10E+02 1.42E+01 2.77E+01 9.96E+01 2.22E+02 1.88E+01 2.19E+01 4.91E+01 3.83E+01 5.10E+01 1.71E+01 1.86E+01 1.91E+01 1.84E+03 3.09E+01 3.65E+01
2.89E+02 3.64E+01 1.08E+02 1.08E+02 5.78E+02 9.77E+01 5.78E+02 1.32E+02 7.09E+01 2.00E+00 1.50E+01 1.80E+01 UUUUU3UUUUUUUUUUUUUUUUU UUUU3,UU3,UUU12pCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/L pCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LUnitsPage 35 of 49 GEL LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com 10 CFR Part 50/61 Isotope Abundance Report GEL Sample ID:
Matrix:Client:Collect Date:
Receive Date:
Client Sample ID:
395827001 WaterVermont Yankee, Entergy Nuclear Operations Inc.
April 11, 2016 April 21, 2016 Torus Water #2 AnalyteActivity Alpha Spec Gamma Spec Ni-63Tc-99 H-3Cs-137Co-60Mn-54Zn-65 7.94E+02 3.89E+03
1.70E+06 1.13E+03 2.07E+04 4.71E+02 1.95E+03 pCi/LpCi/L pCi/LpCi/LpCi/LpCi/LpCi/LUnits% Abundance 000.05 000.22 098.31 000.07 001.20 000.03 000.11Total Activity: 1.73E+06Total % Abundance: 100.00 Page 36 of 49 Quality Control SummaryPage 37 of 49 QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Alpha Spec 15626291562630Batch BatchPlutonium-238 Plutonium-239/240
Plutonium-242 Plutonium-238 Plutonium-239/240
Plutonium-242 Plutonium-238 Plutonium-239/240
Plutonium-242 Americium-241 Curium-242 Curium-243/244 Americium-241 Curium-242
Curium-243/244 Americium-241 Curium-242 ParmnameMr. Mark Vandale Contact:Entergy Nuclear Operations, Inc., VY 530 Governor Hunt Road Vernon, Vermont May 5, 2016 Report Date:
Units pCi/LpCi/L pCi/LpCi/LpCi/L pCi/LpCi/LpCi/L pCi/LpCi/LpCi/L pCi/LpCi/LpCi/LpCi/LpCi/LpCi/LAnlstDateTimeMXS2MXS204/30/16 11:03 04/30/16 11:03 04/30/16 11:05 04/30/16 11:05 04/30/16 11:08 04/30/16 11:05 QC0.1320.08240.07630.04755.710.05450.0605-0.01350.02150.07650.000.02525.270.01446.220.0246-0.00542NOMSample0.01960.04850.1910.04310.00-0.00511RangeN/A N/A N/A(75%-125%)
N/AN/AN/A(75%-125%)
(75%-125%)
QualUU UUUUU UUUU UUQC1203535940 395827001 QC1203535941 QC1203535939 QC1203535947 395827001 QC1203535948 QC1203535946 N/AN/AN/A16.6N/AN/AREC%11610794.14.94 4.936.61DUPLCSMBDUPLCS MB395827Workorder:
PO Box 250 UUUUU U+/-0.214
+/-0.213+/-0.299+/-0.0739
+/-0.0466
+/-0.0441
+/-0.142
+/-0.113+/-0.113+/-0.107+/-0.770
+/-0.108+/-0.0977
+/-0.0611
+/-0.0828
+/-0.101+/-0.055+/-0.0707
+/-0.623+/-0.0539
+/-0.671+/-0.0949
+/-0.0468 RPD%Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 1 of 12 Page 38 of 49 QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Alpha Spec Rad Gamma Spec 1562630156263115626321561698BatchBatchBatchBatchCurium-243/244 Neptunium-237 Neptunium-237
Neptunium-237 Plutonium-241 Plutonium-241 Plutonium-241 Actinium-228 Americium-241 Antimony-124
Antimony-125
Barium-133
Barium-140 Beryllium-7 Bismuth-212
Bismuth-214
Cerium-139 ParmnameUnits pCi/LpCi/LpCi/L pCi/LpCi/LpCi/L pCi/LpCi/LpCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LAnlstDateTimeMXS2MXS2MJH104/30/16 10:57 04/30/16 10:59
04/30/16 10:57 05/04/16 15:25 05/03/16 14:19 05/04/16 13:54 04/22/16 06:34 QC0.006290.22591.80.0941-1.65216-1.4-83.9-30.21.84-5.76-11.255.051.4 27.2 1.581.86NOMSample-0.1667.3842.2-24.3-3.658.30-7.26
-11.239.2-69-1.64-8.99RangeN/A(75%-125%)
N/A(75%-125%)
N/A N/AN/A N/A N/A N/AN/AN/A N/A N/AQualUUUUUUUUU U
U U
UUUQC1203535950 395827001 QC1203535951
QC1203535949 QC1203535953 395827001 QC1203535954 QC1203535952 QC1203533385 395827001 N/AN/AN/AN/A N/A N/A N/AN/AN/A N/A N/A N/AREC%10311189.3194DUPLCSMBDUPLCSMBDUP395827Workorder:
UUUU U
U UUU U
U U+/-0.314+/-11.3+/-63.0+/-41.6
+/-10.9
+/-27.4
+/-13.2+/-65.7+/-94.0+/-177+/-22.1
+/-8.66+/-0.0657
+/-0.654+/-6.94+/-0.422+/-7.13+/-27.4
+/-7.62+/-95.8+/-50.5
+/-15.8
+/-41.9
+/-20.8+/-103
+/-144
+/-257+/-34.0
+/-12.7RPD%Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Page 2 of 12 Page 39 of 49 QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698BatchCerium-141 Cerium-144 Cesium-134 Cesium-136
Chromium-51
Cobalt-56 Cobalt-57 Cobalt-58
Europium-152
Europium-154 Europium-155 Iridium-192
Iron-59 Lead-210 Lead-212Lead-214Manganese-54
Mercury-203
Neodymium-147
Neptunium-239 ParmnameUnits pCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/LAnlstDateTimeMJH104/22/16 06:34 QC-1216.8-8.32
-39.411503.78 5.84 6.90 89.120400-7.8117.7 20.9-2.06-55.9-4140.3657.394810.957-52.1-65.9NOMSample-9.1234.2-135.93113030.7 7.28 3.24 90.02070013.5 17.8 14.3-2.7928.7904-1.47
-6.774718.62-86.370.1RangeN/A N/AN/AN/A(0%-20%)N/A N/AN/A(0% - 100%)
(0%-20%)N/AN/AN/AN/A N/A N/A N/AN/A(0%-20%)N/AN/A N/AQualU U
UUUU UUU UUU U
U UUU UN/AN/AN/A N/A2.28N/AN/AN/A0.9821.55N/AN/AN/A N/A N/A N/AN/AN/A1.95N/A N/AN/AREC%395827Workorder:
U UU UUUUUUU U
U UUUUUU+/-16.7
+/-59.8+/-14.7
+/-34.5
+/-24.3
+/-98.2+/-15.2+/-7.66
+/-20.6
+/-71.0
+/-28.6+/-22.5+/-30.4
+/-9.96
+/-35.5+/-1070+/-19.2
+/-21.5
+/-24.3
+/-10.7+/-133+/-74.3+/-24.6+/-87.5+/-22.6
+/-53.9
+/-36.7+/-147+/-23.3
+/-12.0
+/-28.7+/-103+/-42.7+/-31.6+/-44.2
+/-15.4
+/-53.1+/-1020+/-26.2
+/-32.0
+/-36.4
+/-15.9+/-208+/-115RPD%Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty Page 3 of 12 Page 40 of 49 QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698BatchNiobium-94 Niobium-95 Potassium-40 Promethium-144
Promethium-146
Radium-228
Ruthenium-106 Silver-110m Sodium-22
Thallium-208
Thorium-234
Tin-113Uranium-235 Uranium-238
Yttrium-88
Zinc-65 Zirconium-95 Actinium-228 Americium-241
Antimony-124
Antimony-125
Barium-133 ParmnameUnits pCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/LpCi/LpCi/L pCi/LpCi/LpCi/LAnlstDateTimeMJH104/22/16 06:34 04/22/16 06:39 QC14.9 22.9 16.1 1.11-18.9
-83.913640.9 6.22-15.11550.62216.4155-5.551870-5.381223970015.9-15727.6NOMSample-7.626.97 11.4 1.214.4642.2 31.9-4.466.078.753779.02-38377-1.32195023.7RangeN/AN/AN/AN/A N/A N/A N/AN/AN/A N/A N/A N/AN/AN/A N/A(0%-20%)N/A(75%-125%)
QualU U
UUU U
U UUU U
U UUUUUUU UQC1203533386 N/AN/AN/A N/A N/A N/AN/AN/A N/A N/A N/AN/AN/A N/A N/A3.98N/AREC%11534400LCS395827Workorder:
UUU U
U UUU U
U UUU U
UU+/-11.3+/-13.4+/-51.6
+/-11.4
+/-12.9
+/-63.0+/-104+/-21.4
+/-7.93
+/-12.0+/-356+/-12.8
+/-59.5+/-356+/-5.08
+/-68.5+/-24.0+/-16.4
+/-23.5+/-69.1
+/-16.5
+/-19.7
+/-95.8+/-159+/-33.1
+/-11.1
+/-19.0+/-425+/-19.4
+/-85.7+/-425+/-7.20
+/-96.7+/-36.8+/-399+/-1740+/-46.1+/-241RPD%Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty Uncertainty Page 4 of 12 Page 41 of 49 QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698BatchBarium-140 Beryllium-7 Bismuth-212
Bismuth-214
Cerium-139
Cerium-141 Cerium-144 Cesium-134
Cesium-136
Chromium-51 Cobalt-56 Cobalt-57
Cobalt-58
Europium-152 Europium-154 Europium-155
Iron-59 Lead-210ParmnameUnits pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/LAnlstDateTimeMJH104/22/16 06:39 QC153-119540-68.543.7-75.7-26823.7-66.413700-19981.9267-46.914200-10143.314657.9 45.34.51E+05NOMSampleRange(75%-125%)
(75%-125%)
QualUUUU U
U UUUUUUUUUU UREC%10210313500 13800395827Workorder:
+/-103+/-282+/-768+/-1080+/-142+/-66.4+/-112
+/-478+/-94.4+/-158
+/-354+/-630+/-88.7+/-108+/-87.5+/-408
+/-237+/-136
+/-300+/-74.3+/-199+/-50700RPD%Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty Page 5 of 12 Page 42 of 49 QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698BatchLead-212Lead-214Manganese-54 Mercury-203
Neodymium-147
Neptunium-239
Niobium-94 Niobium-95 Potassium-40
Promethium-144
Promethium-146
Radium-228 Ruthenium-106 Silver-110m
Sodium-22
Thallium-208
Thorium-234 Tin-113Uranium-235
Uranium-238
Yttrium-88
Zinc-65ParmnameUnits pCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/LAnlstDateTimeMJH104/22/16 06:39 QC-41.7
-66.522.0-25.5-2593569.74 28.1-26.76.91-31.7122 16678.214.5-13.8-1950-66.5147-1950-3.091030NOMSampleRangeQualUU UUU U
U UUU U
U UUU U
U UUU UREC%395827Workorder:
+/-143+/-183+/-87.1+/-77.1+/-538
+/-781+/-68.8
+/-77.3+/-253+/-68.5+/-124+/-399+/-727
+/-140+/-47.5
+/-73.8+/-5510+/-108
+/-479+/-5510+/-28.7+/-363RPD%Uncertainty
Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty Page 6 of 12 Page 43 of 49 QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698BatchZirconium-95 Actinium-228 Americium-241 Antimony-124
Antimony-125
Barium-133
Barium-140 Beryllium-7 Bismuth-212
Bismuth-214
Cerium-139
Cerium-141 Cerium-144 Cesium-134
Cesium-136
Chromium-51 Cobalt-56 Cobalt-57
Cobalt-58
Europium-152 ParmnameUnits pCi/LpCi/LpCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/LAnlstDateTimeMJH104/22/16 06:34 QC31.9-7.16
-1.73-0.03870.9600.347-0.895-8.8614.21.92-0.5332.38 5.240.137-1.240.1341.840.706-0.1720.6801.03 1.98NOMSampleRangeQualUUUUU U
U U
UUU U
U UUU U
U UUU UQC1203533384 REC%MB395827Workorder:
+/-141+/-8.38
+/-9.55
+/-2.87
+/-4.35
+/-2.37+/-6.51+/-12.3
+/-25.1
+/-4.84
+/-1.59+/-2.53+/-10.6
+/-1.84
+/-2.06
+/-1.80+/-13.4+/-1.49
+/-1.53
+/-1.64
+/-1.93RPD%Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Page 7 of 12 Page 44 of 49 QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698BatchEuropium-154 Europium-155 Iridium-192
Iron-59 Lead-210 Lead-212Lead-214Manganese-54
Mercury-203
Neodymium-147
Neptunium-239 Niobium-94 Niobium-95
Potassium-40
Promethium-144
Promethium-146 Radium-228 Ruthenium-106
Silver-110m
Sodium-22
Thallium-208 ParmnameUnits pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/L pCi/L pCi/LpCi/LpCi/L pCi/LAnlstDateTimeMJH104/22/16 06:34 QC-0.771-2.76-0.3172.12-1321.26 1.93-0.121.53-3.95-0.573
-0.765-0.074314.30.643 0.158-7.16
-15.7-0.238
-0.342-2.26NOMSampleRangeQualU UUU U
U UUU U
U UUU U
U UUU U
UREC%395827Workorder:
+/-4.87+/-4.66+/-6.43
+/-1.62
+/-2.97+/-275+/-4.97
+/-5.83
+/-1.62
+/-1.59
+/-11.0+/-14.9+/-1.67
+/-1.40
+/-24.8
+/-1.79+/-2.18+/-8.38
+/-18.9
+/-1.98
+/-1.62+/-2.16RPD%Uncertainty Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty Page 8 of 12 Page 45 of 49 QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Rad Gas Flow 1561698156260215626931562716BatchBatchBatchBatchThorium-234 Tin-113Uranium-235 Uranium-238
Yttrium-88
Zinc-65 Zirconium-95 Iodine-129 Iodine-129 Iodine-129
Iodine-129 Nickel-59 Nickel-59
Nickel-59 Strontium-89 Strontium-90 Strontium-89 ParmnameUnits pCi/LpCi/L pCi/L pCi/LpCi/LpCi/L pCi/LpCi/LpCi/L pCi/L pCi/LpCi/LpCi/L pCi/LpCi/LpCi/LpCi/LAnlstDateTimeMJH1MJH1CXS7KSD104/22/16 06:34
04/27/16 09:20 04/27/16 11:04 04/27/16 09:19
04/27/16 09:20 04/28/16 15:36 04/29/16 06:45
04/28/16 15:36 05/02/16 16:24 05/02/16 16:24 QC60.30.153-0.38860.3-0.7980.806-1.70.38850.2-0.1757.53.143722.87-1.39-0.222550NOMSample-0.0373-0.03735.851.080.331RangeN/A(75%-125%)
(75%-125%)
N/A(75%-125%)
N/AN/A(75%-125%)
QualU U
UUU U
UUUUUUUQC1203535844 395827001 QC1203535846 QC1203535843 QC1203535845 395827001 QC1203536150 395827001 QC1203536151
QC1203536149 QC1203536198 395827001 QC1203536199 N/AN/AN/AN/AREC%96.411188.810552.052.0419522DUPLCSMBMSDUPLCSMBDUPLCS395827Workorder:
UUUUU+/-0.859+/-0.859+/-6.40+/-1.29+/-0.980+/-140+/-2.10+/-13.5+/-140+/-1.85
+/-3.61+/-2.56+/-1.13+/-6.44+/-0.835+/-6.83+/-2.49+/-26.7
+/-5.02+/-1.93+/-1.22RPD%Uncertainty
Uncertainty
Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty
Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty Uncertainty Uncertainty Page 9 of 12 Page 46 of 49 QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gas Flow Rad Liquid Scintillation 1562716156267215626781562683 1562687BatchBatchBatchBatch BatchStrontium-90 Strontium-89 Strontium-90 Iron-55Iron-55 Iron-55Nickel-63 Nickel-63
Nickel-63 Technetium-99 Technetium-99
Technetium-99 TritiumTritiumParmnameUnits pCi/L pCi/LpCi/LpCi/LpCi/L pCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LpCi/LAnlstDateTimeKSD1CXS7CXS7MYM1GXR105/02/16 16:24 05/02/16 16:27 04/28/16 23:26 04/29/16 00:13
04/28/16 22:39 04/29/16 14:53 04/29/16 15:09
04/29/16 14:37 05/03/16 15:12 05/03/16 15:28
05/03/16 14:55 04/29/16 23:11 04/30/16 11:54 QC445-1.50.11691.21440-42.58402090-6.46254841-11.41.72E+062410NOMSample95.379438901.70E+06Range(75%-125%)
(0% - 100%)
(75%-125%)
(0%-20%)(75%-125%)
(0%-20%)(75%-125%)
(0%-20%)(75%-125%)
QualUUUU UQC1203536197 QC1203536077 395827001 QC1203536078
QC1203536076 QC1203536093 395827001 QC1203536094
QC1203536092 QC1203536112 395827001 QC1203536113
QC1203536111 QC1203536127 395827001 QC1203536129 4.425.651751.36REC%8386.812497.71025361660 16908612350MBDUPLCSMBDUPLCS MBDUPLCS MBDUPLCS395827Workorder:
+/-60.5+/-71.2
+/-93.7+/-33300+/-13.0+/-10.4+/-1.18+/-1.00+/-58.8+/-86.2
+/-58.1+/-71.1+/-101+/-37.6
+/-33.3+/-48.9
+/-24.1+/-33700+/-461*RPD%Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty Uncertainty Uncertainty
Uncertainty Uncertainty Uncertainty Page 10 of 12 Page 47 of 49 QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Liquid Scintillation 15626871562691Batch BatchTritiumTritiumCarbon-14 Carbon-14
Carbon-14 ParmnameUnits pCi/LpCi/LpCi/LpCi/LpCi/L pCi/LAnlstDateTimeGXR1TXJ104/29/16 22:55
04/29/16 23:13 05/03/16 17:23 05/03/16 18:26
05/03/16 16:51
05/03/16 17:54 QC1361.62E+0628.01310-4.591400NOMSample1.70E+0614.914.9Range(75%-125%)
N/A(75%-125%)
(75%-125%)
QualUUUQC1203536126 QC1203536128 395827001 QC1203536142 395827001 QC1203536144
QC1203536141
QC1203536143 395827001 The Qualifiers in this report are defined as follows:
N/AREC%N/A103111471012601260MBMSDUPLCSMBMS395827Workorder:
- <
>
BDFAH J
KLM MN/AN1 ND NJQR UAnalyte is a Tracer compound
Result is less than value reported
Result is greater than value reported Results are either below the MDC or tracer recovery is low Failed analysis.
Analytical holding time was exceeded
Value is estimated Analyte present. Reported value may be biased high. Actual value is expected to be lower.
Analyte present. Reported value may be biased low. Actual value is expected to be higher.
M if above MDC and less than LLD
REMP Result > MDC/CL and < RDL RPD or %Recovery limits do not apply.
See case narrative
Analyte concentration is not detected above the detection limit Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier One or more quality control criteria have not been met. Refer to the applicable narrative or DER.
Sample results are rejected
Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.
UU+/-33300+/-24.1+/-24.1+/-301+/-31600+/-24.9+/-47.0
+/-23.6
+/-49.8RPD%Uncertainty
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Notes:Counting Uncertainty is calculated at the 95% confidence level (1.96-sigma).
Page 11 of 12 Page 48 of 49 QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com ParmnamePage 12 of 12 Units AnlstDateTimeQCNOMSampleRangeQualREC%395827Workorder:
UIUJUL X
Y^hGamma Spectroscopy--Uncertain identification Gamma Spectroscopy--Uncertain identification Not considered detected. The associated number is the reported concentration, which may be inaccurate due to a low bias.
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Other specific qualifiers were required to properly define the results. Consult case narrative.
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.
Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more or %RPD not applicable.
^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptance criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.
- Indicates that a Quality Control parameter was not within specifications.
For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.
RPD%Page 49 of 49