Ti 2515-193 Summary of Findings
ML21306A344
Person / Time
Issue date: 11/10/2021
From: Aron Lewin
NRC/NRR/DRO/IRIB
To:
Aron Lewin, NRR/DRO/IRIB, 415-2259
References
TI 2515-193
Download: ML21306A344 (1)


Text

Temporary Instruction (TI) 2515/193 Summary of Findings Site Region Inspection Report Date of Issuance Inspection Report ADAMS #

NRC Documented Findings Finding Summary FitzPatrick I

12/10/19 ML19345D572 None Hope Creek I

6/20/19 ML19171A136 One Green Finding Failure to ensure that Severe Accident Water Addition (SAWA) flow indicators would be reliable or functional to provide proper flow indication during an extended loss of alternating current power (ELAP) event.

Limerick I

9/22/20 ML20266G286 None Nine Mile Point I

10/21/19 ML19295E729 None Peach Bottom I

9/9/20 ML20253A254 None Susquehanna I

8/16/19 ML19228A095 None Browns Ferry II 8/24/21 ML21236A028 One Green Finding Failure to perform required surveillances within periodicity for the Hardened Containment Vent System (HCVS).

Brunswick II 10/22/21 ML21298A002 One Green Finding Failure to perform required surveillances within periodicity for the Hardened Containment Vent System (HCVS).

Hatch II 7/15/21 ML21197A000 None Dresden III 7/30/18 ML18211A542 None Duane Arnold III 10/1/19 ML19275D598 None Fermi III 9/10/23 ML19253D015 None LaSalle III 11/29/19 ML19333B843 None Monticello III 5/26/20 ML20147A637 None Quad Cities III 5/17/19 ML19140A084 None Columbia IV 3/24/20 ML20085F489 None Cooper IV 9/23/19 ML19266A571 None