Letter Sequence Other |
|---|
|
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, ... further results|Request]]
- Acceptance, Acceptance
- Supplement, Supplement
Results
Other: ML17153A285, ML17156A093, ML17157B367, ML17180A077, ML17187A035, ML17240A332, ML17262A200, ML17269A051, ML17279A874, ML17298B174, ML17348B167, ML18002A369, ML18003A047, ML18037A836, ML18155A331, ML18155A333, ML18158A335, ML18162A063, ML18162A065, ML18162A066, ML18162A074, ML18173A169, ML18178A152, ML18179A155, ML18183A445, ML18186A088, ML18193B074, ML18197A294, ML18204A079, ML18204A088, ML18204A119, ML18204A129, ML18204A133, ML18204A140, ML18204A146, ML18204A185, ML18213A435, ML18214A146, ML18219A101, ML18219A165, ML18233A182, ML18247A502, ML18247A509, ML18353A835, ML19221B583, ML19295E426, ML19295E427, ML19295F527, ML19309F859
|
MONTHYEARML17153A2852017-05-25025 May 2017 License Renewal Application Project stage: Other ML17156A0932017-06-20020 June 2017 Receipt and Availability of the License Renewal Application for River Bend Station, Unit 1 Project stage: Other ML17186A1592017-07-10010 July 2017 License Renewal Application - Supplemental Information Needed for Acceptance of Requested Licensing Action, Regarding the Application from Entergy Operations, Inc. for Renewal of the Operating License for River Bend Station, Unit 1 Project stage: Acceptance Review ML17180A0772017-07-27027 July 2017 Correction Letter for the Receipt and Availability of the License Renewal Application for the River Bend Station, Unit 1 Project stage: Other ML17157B3672017-07-31031 July 2017 License Renewal Application Online Reference Portal Project stage: Other ML17187A0462017-08-0202 August 2017 License Renewal Pre- Application Coordination Meeting 1 River Bend Nuclear Generating Station Unit 1 - Summary of Meeting Held on April 25, 2017 Project stage: Meeting ML17187A0272017-08-0202 August 2017 License Renewal Application, NRC Presentation Summary of Meeting Held on May 25, 2017 Project stage: Meeting ML17187A0352017-08-0707 August 2017 Determination of Acceptability and Sufficiency for Docketing and Proposed Review Schedule Regarding the Application from Entergy Operations, Inc. for Renewal of the Operating License for River Bend Station, Unit 1 (CAC No. MF9747 and MF9778 Project stage: Other ML17187A0372017-08-0909 August 2017 Summary of Meeting Between the U.S. Nuclear Regulatory Commission Staff and Entergy Operations, Inc. Representatives to Discuss the River Bend Station, Unit 1 License Renewal Application Project stage: Meeting ML17180A1362017-08-0909 August 2017 Summary of Meeting Between the U.S. Nuclear Regulatory Commission Staff and Entergy Operations, Inc. Representatives to Discuss the River Bend Station, Unit 1 License Renewal Application Project stage: Meeting ML17173A1332017-08-0909 August 2017 FRN River Bend Acceptability for Docketing and Opportunity to Request a Hearing and to Petition for Leave to Intervene Project stage: Request ML17240A3322017-09-0707 September 2017 License Renewal Application Review Status Letter Project stage: Other ML17262A2002017-09-25025 September 2017 Plan for the Operating Experience Review Regarding the River Bend Station, Unit 1 License Renewal Application Review Project stage: Other ML17269A0512017-10-10010 October 2017 Plan for the Aging Management Program Regulatory Audit Regarding the River Bend Station, Unit 1 License Renewal Application Review Project stage: Other ML17279A8742017-10-11011 October 2017 Plan for the Scoping and Screening Methodology Regulatory Audit Regarding the License Renewal Application Review Project stage: Other ML17298B1742017-10-31031 October 2017 Audit Plan for the Onsite Aging Management Program Regulatory Audit for the River Bend Station, Unit 1 License Renewal Application Review Project stage: Other ML18004A0662017-12-20020 December 2017 Entergy - Anchor Darling Double Disc Gate Valve Information and Status Project stage: Request ML17348B1672018-01-0404 January 2018 Status Letter - December Project stage: Other ML18002A3692018-01-0808 January 2018 Extension Letter Request Response Project stage: Other L-2018-004, Enclosure 2 - Applications for Withholding Proprietary Information from Public Disclosure Pursuant to 10 CFR 2.3902018-01-30030 January 2018 Enclosure 2 - Applications for Withholding Proprietary Information from Public Disclosure Pursuant to 10 CFR 2.390 Project stage: Request ML18037A8362018-01-31031 January 2018 Appendix E - Turkey Point Nuclear Plant Units 3 and 4 Environmental Report Subsequent Operating License Renewal Stage Project stage: Other Press Release-18-009, NRC Makes Available First Subsequent License Renewal Application from Turkey Point Nuclear Power Plant2018-03-22022 March 2018 Press Release-18-009: NRC Makes Available First Subsequent License Renewal Application from Turkey Point Nuclear Power Plant Project stage: Request L-2018-086, Subsequent License Renewal Application Appendix E Environmental Report Supplemental Information2018-04-10010 April 2018 Subsequent License Renewal Application Appendix E Environmental Report Supplemental Information Project stage: Supplement ML18003A0472018-04-26026 April 2018 Determination of Acceptability and Sufficiency for Docketing, Proposed Review Schedule, and Opportunity for a Hearing Regarding the Application from FPL for Subsequent Renewal of the Turkey Point Units 3 and 4 Project stage: Other ML18155A3292018-05-27027 May 2018 Comment (1) of Matthew Cook on Florida Power & Light Company; Turkey Point Nuclear Plant Units 3 and 4 Project stage: Request ML18155A3312018-05-28028 May 2018 Comment (2) of Hannah Gardiner Supporting License Renewal for Turkey Point Nuclear Plant Units 3 and 4 Project stage: Other ML18155A3322018-05-30030 May 2018 Comment (3) of Gabriel Ignetti on Turkey Point Nuclear Plant Units 3 and 4 Project stage: Request ML18155A3332018-05-30030 May 2018 Comment (4) of John Karahalios Supporting License Renewal of Florida Power & Light Company; Turkey Point Nuclear Plant Units 3 and 4 Project stage: Other ML18162A0632018-05-31031 May 2018 Comment (6) of Anthony Denardo Supporting Turkey Point Nuclear Plant, Units 3 and 4 License Renewal Project stage: Other ML18155A3342018-05-31031 May 2018 Comment (5) of Elaine Trotter on Turkey Point Nuclear Plant, Units 3 and 4 Project stage: Request ML18187A2212018-05-31031 May 2018 Documents Provided by Laura Sue Wilansky to the U.S. Nuclear Regulatory Commission During the Turkey Point Nuclear Generating Units 3 and 4 Public Environmental Scoping Meeting on May 31, 2018 Project stage: Request ML18187A2242018-05-31031 May 2018 Documents Provided by Steve Schoedinger to U.S. Nuclear Regulatory Commission During the Turkey Point Unit 3 & 4 Public Environmental Scoping Meeting on May 31, 2018 Project stage: Request ML18162A0652018-06-0202 June 2018 Comment (7) of James Hopf Supporting Turkey Point Nuclear Plant, Units 3 and 4 License Renewal Project stage: Other ML18162A0662018-06-0303 June 2018 Comment (8) of D. Sotelo Opposing Turkey Point Nuclear Plant, Units 3 and 4 License Renewal Project stage: Other ML18162A0672018-06-0303 June 2018 Comment (9) of Jonathan Bauer Objecting to Extension of the License of Florida Power & Light Company, Turkey Point Nuclear Plant Units 3 and 4 Project stage: Request ML18162A0682018-06-0404 June 2018 Comment (10) of Diane Johnson on Turkey Point Nuclear Plant Units 3 and 4 Project stage: Request ML18162A0692018-06-0505 June 2018 Comment (11) of Sarah Fangman of Us Dept of Commerce, National Oceanic & Atmospheric Admin on Florida Power & Light Company; Turkey Point Nuclear Plant Units 3 and 4 Project stage: Request ML18162A0702018-06-0606 June 2018 Comment (12) of Ian Zink on Florida Power & Light Company; Turkey Point Nuclear Plant Units 3 and 4 Project stage: Request ML18162A0742018-06-0707 June 2018 Comment (13) of Robert Pike on Florida Power & Light Company; Turkey Point Nuclear Plant Units 3 and 4 License Renewal Project stage: Other ML18179A1582018-06-0707 June 2018 Comment (28) of Kirk C. Zuelch on Behalf of Florida Keys Aqueduct Authority on Florida Power and Light Application for Renewal Project stage: Request ML18163A1132018-06-0909 June 2018 Comment (14) of Patricia Milone on Turkey Point Nuclear Plant Units 3 and 4 Project stage: Request ML18169A1522018-06-12012 June 2018 NRR E-mail Capture - (External_Sender) SNO Requests Consultation Meeting with Nrc/Fpl at Turkey Point Nuclear Power Plant Project stage: Request ML18158A3352018-06-13013 June 2018 License Renewal Environmental Site Audit Regarding the Turkey Point Nuclear Generating Units 3 and 4 Subsequent License Renewal Application Project stage: Other ML18179A3632018-06-14014 June 2018 Comment (35) E-mail Regarding T.P. 3&4 SLR EIS Scoping Project stage: Request ML18179A2322018-06-14014 June 2018 Comment (25) E-mail Regarding T.P. 3&4 SLR EIS Scoping Project stage: Request ML18179A3542018-06-14014 June 2018 Comment (34) E-mail Regarding T.P. 3&4 SLR EIS Scoping Project stage: Request ML18179A3412018-06-14014 June 2018 Comment (33) E-mail Regarding T.P. 3&4 SLR EIS Scoping Project stage: Request ML18179A3332018-06-14014 June 2018 Comment (32) E-mail Regarding T.P. 3&4 SLR EIS Scoping Project stage: Request ML18179A2452018-06-14014 June 2018 Comment (31) E-mail Regarding T.P. 3&4 SLR EIS Scoping Project stage: Request ML18179A2352018-06-14014 June 2018 Comment (27) E-mail Regarding T.P. 3&4 SLR EIS Scoping Project stage: Request 2018-01-08
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 October 10, 2017 Mr. William F. Maguire Site Vice President River Bend Station, Unit 1 Entergy Operations, Inc.
5485 U.S. Highway 61 N St. Francisville, LA 70775
SUBJECT:
PLAN FOR THE AGING MANAGEMENT PROGRAM REGULATORY AUDIT REGARDING THE RIVER BEND STATION, UNIT 1 LICENSE RENEWAL APPLICATION REVIEW (CAC NO. MF9747)
Dear Mr. Maguire:
By letter dated May 25, 2017, Entergy Operations, Inc. (Entergy) submitted an application for Renewal of Operating License No, NPF-47 for the River Bend Station, Unit 1 (RBS). The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants.
The staff plans to conduct its Aging Management Program Regulatory Audit remotely from NRC headquarters offices (in-office audit) from October 16, 2017 through November 3, 2017, in accordance with the enclosed regulatory audit plan. If you have any questions, please contact me by telephone at 301-415-4084 or by e-mail at Emmanuel.Sayoc@nrc.gov.
Sincerely,
/RA Albert Wong for/
Emmanuel Sayoc, Project Manager License Renewal Project Branch Division of Materials and License Renewal Office of Nuclear Reactor Regulation Docket No. 50-458
Enclosure:
Audit Plan cc w/encl: Listserv
ML17269A051
ENCLOSURE Audit Plan Aging Management Program Regulatory Audit for the River Bend Station, Unit 1 License Renewal Application Division of Materials and License Renewal Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission License Renewal Aging Management Program Regulatory Audit Plan River Bend Station, Unit 1
- 1.
Background
By letter dated May 25, 2017, Entergy Operations, Inc. (Entergy), submitted to the U.S. Nuclear Regulatory Commission (NRC or the staff) its application for Renewal of Operating License No.
NPF-47 for the River Bend Station, Unit 1 (RBS). RBS requested renewal of the operating license for an additional 20 years beyond the 40-year current license term, which expires on August 29, 2025. The staff from the Division of Materials and License Renewal will lead a regulatory audit to gain a better understanding of Entergys aging management programs (AMPs), aging management review (AMR) items, Time-Limited Aging Analyses (TLAA) and associated bases and documentation as applicable.
- 2.
Regulatory Audit Bases License renewal requirements are specified in Title 10 of the Code of Federal Regulations (CFR), Part 54 (10 CFR Part 54), Requirements for Renewal of Operating Licenses for Nuclear Power Plants. Guidance is provided in NUREG-1800, Rev. 2, Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants (SRP-LR), dated December 2010, and NUREG-1801, Rev. 2, Generic Aging Lessons Learned (GALL) Report, dated December 2010.
- 3.
Regulatory Audit Scope The scope of this regulatory audit is to: (a) examine Entergys AMPs, AMR items, and TLAAs for RBS; and (b) verify Entergys claims of consistency with the corresponding GALL Report AMPs, and AMR items, and (c) assess the adequacy of the TLAAs. Enhancements and exceptions will be evaluated on a case-by-case basis. The staffs review of enhancements and exceptions will be documented in the safety evaluation report.
During this audit, the staff will audit Program Elements 1 - 6 (scope, preventive actions, parameters monitored or inspected, detection of aging effects, monitoring and trending, and acceptance criteria), and Program Element 10 (operating experience) of the applicants AMPs against the elements of the associated AMP described in the GALL Report. Program Elements 7 - 9 (corrective actions for general recommendations such as compliance with Appendix B, confirmation process, and administrative controls) are audited by another NRC project team during the scoping and screening methodology audit, and are evaluated separately. In addition, the staff will verify that the conditions at the plant are bounded by the conditions for which the GALL Report program was evaluated.
The staff will also examine the applicants program bases documents and related references for AMPs, AMR items, and TLAAs, perform selected in-plant walkdowns, and interview applicant representatives to obtain additional clarification.
The staff will use risk insights to inform the prioritization of its review of documentation associated with AMPs, AMR items, and TLAAs. The staff will use risk insights to focus the breadth and depth of its review of plant specific operating procedures and operating experience.
However, the staffs review is not limited to risk significant systems and components because 10 CFR Part 54 is a deterministic rule and the staff must conclude that there is reasonable assurance that activities will continue to be conducted in accordance with the current licensing basis and the effects of aging will be managed during the period of extended operation for all structures and components within the scope of Part 54.
The staff has reviewed the list of risk significant systems and components (from PRA, Revision
- 5) provided in a presentation to the staff on May 25, 2017. The staff augmented this list with the fire protection and fire water systems because they are typically risk significant when considering external events.
- 4.
Information and Other Material Necessary for the Regulatory Audit The project team will review the license renewal application, the AMP basis documents and other Entergy supporting documents as appropriate.
For the in-office audit October 16, 2017 - November 3, 2017:
The project team would like continued Entergy document review capability via the CERTREC document portal. Document requests for upload to the portal shall be made as needed via the NRC safety project manager to the appropriate Entergy licensing manager.
The NRC staff would like to hold break-out sessions, via telephone conference calls and/or official internet based desktop sharing means, with Entergy and RBS subject matter experts to discuss various basis documents, references, condition/corrective action reports, and interview Entergy representatives to obtain additional clarification related to the license renewal review. Break-out sessions for various technical review areas will occur at predesignated time slots during the audit, with preassigned NRC and Entergy representatives. NRC staff will provide discussion topics and technical requests/questions to the NRC safety project manager, who will then relay the information to the Entergy licensing manager. All break-out sessions will be coordinated via the NRC safety project manager and the Entergy licensing manager.
- 5.
Team Assignments Assigned Auditor Area of Review Emmanuel Sayoc Project Manager James Gavula Chemistry and Corrosion Brian Allik Chemistry and Corrosion William Gardner Chemistry and Corrosion Alan Huynh Chemistry and Corrosion Sadollah Mohammed Electrical Duc Nguyen Electrical William Holston Mechanical and Materials Aaron Mink Mechanical and Materials Bart Fu Mechanical and Materials Mark Yoo Mechanical and Materials James Medoff Mechanical and Materials Seung Min Mechanical and Materials Naeem Iqbal Mechanical and Materials Amrit Patel Mechanical and Materials Angela Buford Structural Juan Lopez Structural Andrew Prinaris Structural Samuel Cuadrado DeJesus Structural Bryce Lehman Structural George Thomas Structural Dan Hoang Structural
- 6.
Logistics The regulatory audit will be conducted with an in-office (at NRC HQ) audit portion from October 16, 2017 through November 3, 2017. Entrance and exit briefings will be held at the beginning and end of the in-office audit. Status calls during the in-office (at NRC HQ) audit will take place weekly.
- 7.
Special Requests The staff requests the applicant to make available the license renewal application program basis documentation and license renewal drawings (hard copy), and their condition report database (electronic version access) for independent searches by the regulatory audit team. Electronic copies of the Key-word Search Results should be made available for the staffs use. Applicant personnel responsible for or involved with the various programs should also be available.
- 8.
Deliverables An audit report should be issued to Entergy within 90 days from the end of the audit.