Safety Evaluation Supporting Amends 171 & 109 to Licenses DPR-57 & NPF-5,respectively
ML20070M766
Person / Time
Site: Hatch  Southern Nuclear icon.png
Issue date: 03/18/1991
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20070M762 List:
References
NUDOCS 9103210428
Download: ML20070M766 (15)


Text

,

ge esog h

O f' 3 y !IJ UNITED STATES I

NUCLEAR REGULATORY COMMISSION W AaHINGToN, D.C. agL26 SAFETY EVALUATION BY THE OFFICE OF NVOLEAR REACTOR REGULATION

,RELATED TO AMENDMENT NO.171 TO TACILITY OPERATING LICENSE OPR 67 AND AMENDMENT NO.109 TO FAClllTY OPERATING LICENSE NPF 5 G10RGIAPOWERCOMPANY.ETAL.

EDWIN 1. HATCH NUCLEAR PLANT, UNITS 1 AND 2 DOCKET N05. 60 321 AND 50-366 1.0 -INTRODUCTION By letter dated August 20, 1990, Geotgia N w Company, et al., the licensee for the Edwin 1. Hatch Nuclear Plant, prc@osed changes to the Technical Specifica-tions (TSs) and Environmental Technical Specifications (ETSS) for Units 1 and 2.

The proposed changes would modify the TSs and ETSt for Units 1 and 2 as follows:

1. Change Unit 2 15 Table 3.2.2-1 to replace the master parts list (MPL) for items 1.f and 4.g.
2. (a) Change Unit 1 TS Table 4.2 2 to correct the spelling of ' Emergency
  • under Reference-ho. 8.

(b)ChangeUnit2TSTable3.3.6.1-1tocorrectthemeasurementr$nge for the off-gas post-treatment monitors, and TS 4.6.6.1.1.d.3 to incorporate a plus/minus sign for the range of heat dissipated by the standby gas treatment subsystem heaters.

(c)_ Delete the list of Figures in the ETS Table of Contents for Units 1 and 2.

3. Change Unit 2 TS 3.8.2.5 and TS Table 3.8.2.6-1 to make editorial j

corrections.

2.0 Q ALVATION i

2.1'_ Proposed Change 1

-This proposed change to Unit 2 TS Table 3.3.2-1, ' Isolation Actuation

< Instrumentation," would make revisions that are editorial in nature.

It would j

correct the MPL numbers under Item 1.f. " Turbine Building Area Temperature t

-High,* and Item 4.g, "Supression-Pool Area Temperature Timer Relays." The specific MPL changes for.l.f would replace designators 2061-R001 through R004 to 2061 P001 through P004 and 1or 4 9 from 2E41 to 2E51.

The proposed change

'to 4 9 corrects a typographical error, while the proposed change to item 1.f reflects the change in indicator panels. These changes are acceptable because they do not affect plant opera. tion, and the safety-related equipment is not changed.-

bb ob P

P l

4 l

2 2.2 proposed Change 2 These proposed changet to the Unit 1 and Unit 2 T$s end ETS$ would make revisions that are editorial in nature. The specific administrative changes proposed to provide clarity are as followst

.l Unit 1 Table 4.2 Correct the spelling of 'Energency* under Reference J

No. B.

1 Unit 2 Table 3.3.6.11-Correctthemeegurementrangeoftheoffgas pos}.treatgentmonitorsfrom10*g to 10* countspersecond(eps)to

['

10 to 10 cps.

Unit 2 Surveillance Requirement 4.0.6.1.1.d.3 Correct the range of heat dissipated by the standby gas treatment subsystem heaters from 18.5 4 1 5 kW to 18.5

  • 1.5 kW.

J Units 1 and 2 ETS Table of Contents - Delete the litt of Figures in the ETS Table of Contents since Figure 5.21 is the only figure listed and it was deleted in Amendments 145 end 80 for Units 1 and 2, respectively.

These changes are found acceptable because they are considered editorial changes that do net effect plant operation or safety ard involve no physical changes to the plant.

d l

2.2 proposed Change 3 This proposed change to the Unit 2 TSs would make revisions that are editorial in nature. The specific administrati'fe changes proposed to provide clarity are j

as follows:

TS 3.8.2.5 Items a, b, e and d - Correct the word ' Circuit" to

  • Breaker,*

and for item c, the breaker numbers 26 and 32 would change to 28 and 34, respectively.

Also, for Item d, the term, ' Compartment" would change to

' Frame

  • Table 3.8.2.6 Relocate items c.3 and c.4 to the next page of the table and change the designation for the drywell cooling unit breakers from thermal magnetic breakers to magnetic only breakers.

Further, the secuential lettering for Type 6 and Type 7 devices would be corrected, anc throughout the tabic, changes would be made to reflect current equipment designation and to make the termit. ology consistent with other design documents.

These changes are found acceptable because they are considered editorial changes that do not affect plant operation or safety and involve no physical changes to the plant.

e$-

3.0 E_NVIRMMEhTAL CCNSIDERATION These amendments involvt changes in reavirements with respect to the installa-tion or use of facility components located within the restricted area as defined in 10 CFR Part 20 and changes in surveillance requirements.

The staff has determined that the amendraents involve no significant increase in the amounts, and no significant change in the types, of any effluents that may be released offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. The Comission has previously issued a proposed finding that the amendments involve no significant hazards consideration, and there has been no public consnent on such finding.

Accordingly, the amendments meet the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9).

Pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the issu6nce of the amendments.

4.0 CONCLLISION The Comission's proposed determination that the amenonents involve no significant hazards consideration was published in the Federal Register on October 31, 1990 (55 FR 45081), and the State of Georgia was consulted.

No public comments were received, and the $ tate ff Georgia did not have any coments.

We have concluded, based on the considerations discussed above, thats (1) there is reasoneble assurance that the health and safety of the public will not be endangered by operation in the proposed tranner, and (2) such activities will be conducted in compliance with the Commission's regulations, and the issuance of the amendments will nct be inimical to the common defense and security or to the health and safety of the public.

Principal Contributor: Kahtan N. Jabbour, PDI!-3/DRP-!/!!

frank Rinaldi, PD]!-3, DRP-!/Il, hRR Dated: March 18, 1991

-r ATTACHMENT TO LICENSI _ AMENDitENT N0.17L i

FACILITYOPERATINGLICENSENO.DPR-5]

}

DOCKET NO. 50-321 Replace the following page of Appendix 'Awith the enclosed page and remove one page from Appendix 'B' Technical Specifications. The revised page is identified by Amendraent number and contains a vertical line indicating the area of ;hange.

Appendix A t

Remove Page Insert P qe j

'Jnit 1 -

3.2 27 3.2 27 Appendix B iii(ETS)

.7

?

s a-1

)

..c.,~-.

...----_...-._.__2_,..-,_....,,-...

s 2.

i. t t

t :

- I

.t r.

.r..r r.

r.

r rr

x
x. x. x x.
x. x x.

m 1, t l 4 66 4 1

1 6 l-t s.

s.

s.

s.

s.

s.

s.

s.

~

- -li l l ii&

I Ii I

g x,

e

.i t

c g

.t i

1,1,2 ng

.e e.

e 1

I.

I I

i Ii I

. s s

s s

-. e s s

s.

s.

s s.

s s

11 1 5

.i

-x e r 6

6 4

s A

e*

1b.

6 1,

.s 4

1-

?. :. 1b

-2 w

w

-6

.e e

e e

4; e

.e 1.'.

t 4

t.

6 g

e

~5 gs,E E& E E

E 5E b

f

-r 4

..I I

lT T

& t

~

- t L

l S.

1

e t

t ;

t

..L 2

g i

}

I3 i

}

4 I$

  • I S'

2

'y Py}

o C t i 3

0 6

tj t A-t 2 2

~

~

t

.t t.

ct 6

. r s"

1-2 r

6 i

2

[ [ - t.t gt. !!

y I. t 0 tt 2

T l-6 a

.z a-i= f' %

.c

.c, s e HATCH - VfilT 1 3.2 27

' s o...:.,,

i 'I.l*

t.a ',*," ^ e

.,* *. ( H #. ** j n

~.

ATTACHMENT TO LICENSE AMEN 0i', TNT NO.109

,FAtiLITY OPERATING LICENSE NO. NPF-5 DOCKET NO. 50-366 Replace the following ppes of Appendh "A" with the enclosed pages and remove one pone from Appendix 5" Technical Specifications. The revised pages are k

identified by Amendinent number and contain vertict.1 litas indicating the ertas of chonte.

Appendix A Remove Page insert Page Unit 2 3/4 3-11 3/4 3-11 3 13 3-13 3-44 3 44 6-41 6 41 8-17 8-17 B-20 8-20 8-21 8-21 8-22

8. ? ?

8 23 8 23 Appendix B iii(ETS)

~

x

%).

~

.4

-taritI_J,3 A 8 JE 150t Attp: ActnAlgow twstryantAttow

-e3

= :-

1

,j 1

~

vuvt Grottr$

- Mimimet 8stret r APPt tt Ant t

~

OPtWAltil Dr.

DPf WattiI UiAfr# I S Def RAIIUsent j

' 1RI c.JJ 8st!.ID'!

5f 6HAliaL_

et # f *l e.57588 M hlid

_w miI;pe; Act)gw

-4 1.

PflMAstLCONI.AINNENL150L AJION eu

'a.

Reactor Wessel Water tewes.

1 tow fievel 3)

2. ti.

20 I

3. 2. I 70

(?ft21 seMID A. R. C. D) 18 12 2.

tow-tow (level 2) '

.?

t. 2. I:

20 (2821-for.82 A. 8. C. D)-

1.

t ow-t ow-t ow t ievel 1):

1

~/

' 7 t!

le

(?fi21 le689 A. 8. C. D) b.

r;rywell Pressure - High 7.

f., F. 10

/~.

I J 2.1 10.

L(2CF1-8eb50 A. 8. C. D) f/.

c.

Main Steam tiae 1

Radiation-- High I. 8/.

3. 7; f.'**

15 --

.(20sI-Kr.03 A. 8. C. D) 2.

Presswre - Low I

2 8

//

w 12821-180 85 A. 8. C. DI 1-N t.

F low - fligh 8

//l sne '

t. 2 4

.?!

(282 8 Nf416 A. 8. C. 0) w (2821-88b8F A. 8. C. D)

/

(2R?f 8 EMIR A. 8. C. D)

(2821 N689 A 8, C. D) w d.

Main Steam Isae Tuaael temperatwre - High 7/line" t, 2. 1

/t (2828-8eb25 A.' 8..C. 8)

(282 8-88624 A. 3. C. D)

(1921 8s625 A. 8. C. p)

(282 8 88626 A. 8. C. D) e.

Coadcase e vacwe== - tow I

2 I. 2.'.3' 21 (2921 88956 A. 8. C. D) f.

Turbine 'loilding Area

[

feuperatore - High t

2*'

t, ;*, t 23 to

- (2U6I-P90t. AmI-P902. 7tmI-P901 5

2U61-P964) 3 8

g.

Drywell Radiation - High t

1. 7. 3 79 re (2Dil-K621 A 8) 2

?

~

O to

..~b-

- - x o

.e

??

'A -

>.J.4. h.I R eat 48'ved!'

1501,AJ 8c8 ACILMt10's I'f57%m88 A'104 x

Milette r *

  • 4 APPtf(aptI

, val Vy Geotr$

081 RAttti fw ntymapr.. s 5

Ort sat trman G

Ik f 8' IF(8 IO's 58'/*St (#1 81 sr t w i e.,.

3.,., i,,,

g,g.a i t gg.e_

artige 5

4 UlW. 8M$t*L_IO0t_ ANT INJECflDN_3Yhst M_15'J! AfID'8 ro HfTI Steam t ine Flow - High.

4 I

1. /. 1 a.

(2t41 88657 A.8) b.

HPCI Steam Supply Pressore -

toe tit 41 Nf,58 A.B.C.09 1, 8 _

'2

8. 7. 1 26 c.
sPCI fort,ine 1.haust Diophrap Fressere - Hsqh (2E41-18655 A.B.C.D).

..,l -.

7

3. 2. 1 7.-

d.

Br(f Pipe Penetratiese Neem temperattare - High (2t41-fe675 A. B) 1.

.I

1. 2. 3 its

$d c.

Suppression Pool Area Ambient

.A

' f raperaterre-ffieph (2t59 8CA,6 C. D) ~

1-8 f

7. I 76 ca e

U f.

Suppression Pnel Area w temp. High (N59 se665 C. 9:

3 I

1. 7. 3 76 2t59-88663 C. D:.

2E5t 88664 C.'D) q.

Suppression Pool Area Temperatore-Iimer Relays (2151-760 5 A.' D) '

3 i

8. 7. 9 26 h.

Emergency Area Cooler Temperatore.

High (2t41 f8679 A. 9).

l' "

I

1. 2. 3 76
i. Dryw f1 Pressure-High 12 tit-8eb s I. D) 8 1
1. 2 3 26
j. t ogic Po-er Moni tor (2f 4 8-4t t )

ses * **

  • I 3. 7. 11 77 o

3 Q.

2m 3

rt 2

O M

O to e

~ ' ' ' '

~

7-1

+

"r t AMe t.j;j,b, t-t

" 2=

-4 WAf I Al f 988 Mfdl f ler tNG ' IN$ f Wipe Nt a l iges i

'n-Z

,g'..

. AITtf(AMit MINIMM fit 44EPff f 5 081 N AIIfMAI. At ARM / f f f f*...

M A5illPf 945 ff t

.E l'85'L'UMI Nia 81988

_ O'T eassi (

- (posts:1inw$.

,3 339 twt,.

_ eAest,e,

at * *Use.

d 1

' O t t -(.a s N

' Pet-treatment avai t ers 7

t. z.

(,1

.-10[to10kcps

'. (iDIl-R685 A. fil !

l-so t.

(nentrol team t

Intate Monitors' 7

1, 7, 1, 4.

t r/t.,

- c., e t t. 's tro ft.

53

- ( t/41 Ittel5 A, it) i

^

i.

..t t

ta i

Nu Y

Valoc not to esteed the egulwalent of the stsch release 14mit -ind,(ate 19 in the

^ i.

h faviron ental icehnical St -eifirations; a

5

?

I F

I CL 2

^O 3

.O i,

i a

s.

O to

-7 t

1

',.t

, a; A.

.a

- ~ - - "~

~ ~ ^ ~ ~ ' ' ' " "

~

CONTAINMENT SYST[MS SURVEILLANCE REQUIREMENTS (Continued) 3.

Verifying a system flow rate of 4000 +0, -1000 cfm during system eperation-when tested in accordance with ANSI N510-1975.

c.

After every 720 hours0.00833 days <br />0.2 hours <br />0.00119 weeks <br />2.7396e-4 months <br /> of charcoal adsorber operation by verifying within 31 days after removal that a laboratory analysis of a' representative carbon sample obtained in accord-Ante with Regulatory Position C.6.b of Regulatory Guide 1.52, Revision 1. July 1976, meets the laboratory testing criteria of Regulatory Position C.6.a cf Regulatory Guide 1.52, Revision

-1, July 1976.

d.

At least once_per 18 months by:

1.

_ Verifying that_-the pres 5Ure drop across the combined HEPA filters' and charcoal adsorber banks is < 6 inches Water Gauge while operating the filter train at a flow rate of 4000 -0, -1000 cfm.

2.

Verifying that the filter train starts 4nd isolation dampers.open on each of the following test signais:

a '. Drywell pressure-high, b.

High ractation on tne; 1)

Refueling floor, 2).

Reactor-building, c.

Reactor Vessel Water Level-Low Low (Level 2).

3.

Verifying that_the heaters dissipate 18.5 t l.5 KH l

when tested in accordance with' ANSI N510-1975.

Amendment No. 109 HATCH - UNii 2 3/4 6-41 i

?

i 5

g

.(LECTRICAL POWER SYSTEMS:

A.C.~ CIRCUITS INSIDE PRIMARY CONTAINMENT

LJylTING CONDIT10NS FOR OPERAT10N 1

3.8.2.5 The following A.C. Circuits inside-primary containment shall be de-energized':

' a ~. Breaker Numbers 2, 4, 6.- 8,10,12,14, 40 and 42 in panel l

2T51-5003, b.

Breaker Numbers 2, 4, 6 -8, 10, 12, 40 and 42 in panel 2T51-l

5004, C.

Breaker Numbers 28f and: 34 -in panel 2R25-5105,- and l

d. : Frame IEL on MCC 2R24-5014 l

APPLICABILITY 1 CONDITIONS 1, 2 and 3.

. ACTION:

With any.of the above required circuits _ energized, trip the associated circuit.breater(s).in-the specified panel within') hour.

SURVEILLANCE RE0'J1REMENTS i-

...4,8.2.5.!Each'of the above required A.C. circuits sh'll be determined to-a be:de-energized at.least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.by verifying that the associated

~

circult breakers-in the specified panels lare in.t_he tripped condition.

-r

  • Except during_ entry into-the drywell.

. HATCH - UNIT 2 3/4 B-17 Amendment No.

109

4

. 13 q

~

TABLE 3.B.2.6-1 PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURR!NT P401ECTiVE DEVICES DEVICE NUMBER SYSTEH/ COMPONENT AND LOCATION *-

POWERED a,

Type-1:

1.

4KV CKT BRKR REACTOR RECIRC WTR PUMP 2R22-5001. FR S MG SET-2A DRIVE HOTOR 2831-5001A 2.

4KV CKT BRKR RECIRC A PUMP MOTOR

-2R22-5008, FR 2 2831-C001A 3,

4KV CKT BRKR REACTOR,RECIRC WTR PUMP 2R22-5002, FR 5 MG SET 2B DRIVE HOTOR 2831-S001B 4

crV CKT BRKR RECIRC B PUMP MOTOR 2R22-5009, TR 2 2831-C0018 b.

Type-2:

1.

600 VAC.-MCB, TM DRYWELL AREA COOLING UNIT 2R24-5012. FR 2DL 2T47-8009B r

2, 5:; VAC, fiCE, '"

DRYWELL AREA COOLING UNIT-2R24-5012,.FR 20R 2T47-8009B 3,

6001VAC, MCB, TM DRYWELL AREA COOLING UNIT 2R24-5012, FR 3fL 2T47-B008S 4.-

600 VAC. MCB, TM DRYWELL AREA COOLING UNIT.

2R24-5012, FR 3FR 2T47-8008B

5. '600 VAC,~MCB, TM

.ORYWELL AREA COOLING UNIT 2RP> $01), FR 1DL 2T47-8008A e

6.

60'.

,AC, MCB, TM DRYWELL AREA COOLING UNIT 2ki,-5011,'FR 1DR 2T47-8008A 7.

600 VAC, MCB. TM DRYWELL. AREA COOLING UNIT 2R24-5011, FR 20AR 2T47-8009A B,

600 VAC, MCB, TM DRYWELL AREA COOLING UNIT 2R24-5011. FR-20E 2T47-8009A i

-'MCB

. molded case circuit breaker MO - magnetic only TM - thermal magnetic HATCH - UNIT 2 3/4 B-20 Amendment No, - 109

h r

"i J a

s

. 3:

TABLE 3.8.2.6 1 (Continued)'

PRIMARY CONTAINMENT PENETRATION CONDUCTOR OV!RCURRENT-PROTECTIVE DEVICES DEVICE NUMBER SYSTEM / COMPONENT ANDLOCA11Cil POWERED c.

Type 3:

- 1.

600:VAC MCB, TM RECIRC PUMP MOTOR HEATER 2R24-5014, FR SE 2B31-C001B'

~2.

600 VAC, MCB. TM RECIRC PUMP MOTOR 2R24-5013, FR 5B HEATER 2B31-C001A

'd..

lype'4:

1.

120 VAC.'MCB. TM CABLES BHE808M01 AND

-2R25-5102. BRKR 10 BHE808M02

-2.

120 VAC, MCB, TM CABLES BGE708M01 AND 2R25-5101, BRKR 10 BGE708M02 lei _ Type; 5:-

1.

600-VAC, MCB, M0 LORYWELL EQUIP DR SUMP PUMP 2R24-5014, FR 2A DISCH MOV 2G11-F018-2.

600 VAC; HOB,'HO ORTHELL EQUIP OR SUMP PUMP-2R24-5014, FR 6C' DISCH MOV 2Gil-F015-3.

600 VAC, MCB', MO RCIC STEAM SUPPLY 2R24-50128,:FR 4A ISOLATION MOV 2E51-F0071 4.

L600:VAC, MCB, MO

~ REACTOR HEAD SPRAY' VALVE

~2R24-5011.,FR 9A MOV.2Eli-F022 5.--

600;VAC,iMCB. MO HPCI~ INBOARD STEAM

'2R24-5011A,=FR 4A -

ISOLATION MOV 2E41-F002 6,; 600 VAC, MCB, MO RWCU INBOARD. ISOLATION 2R24-5011, FR 14C-

. VALVE'MOV-2G31-F001 L7. 600 VACelCB. MO MAIN STEAM LINE DRAIN 2 R24-5011_, FRLISB VALVE MOV 2821-F016 1

L

'MCB - molded. case circuit breaker h

MO - magnetic lonly1 l

TMi ; thermal magnetic-P HATCH - UNIT-2 3/4 8-21 Amendment No.109 u

~..

~.

[f" L

-. 4.

r

+

-T ABL E 3. 8. 2'. 6-1 (Cont inued )

PRIMARY CONTAINMENT PENETRATION CONDUCTOR-OVERCURRENT PRol[CT]VE DEVICE _$

DEVICE NUMBER SYSTEM / COMPONENT AND LOC ATION*

POWERED f.

Type 6:

1.

600-VAC,- MCB-MO RECIRC PUMPJSUCTION VALVE 2R24-5018A, FR 2A MOV 2B31-F023A U

2.

600 VAC, MCB, MO RECIRC PUMP DISCHARGE VALVC 2R24-5018A,-TR 25 MOV 2831-F031A 3.

600 VAC, MCB, MO RECIRC PUMP SUCTION VALVE 2R24-501BB,'FR 3A MOV 2B31-F023B 4

600 VAC,.MCB, MO.

RECIRC PUMP DISCHARGE-VALVE 2R24-501BB, FR 3B MOV 2B31-F031B 5.

600 VAC, MCB, MO ORYHELL EOUIP DRAIN-SUMP 2R24-5014, FR 1B PUMP B 2G11-C006B-6.

633 VACE MCB, MO ORYNELL FLOOR ORAIN SUMP 2R24-5014, FR 70 PUMP B 2G11-C0016-7.

600'VAC.MCB, MO DRYWELL FLOOR-DRAIN SUMP R2; 2012, :R 4A PUMP 1A-2G11-C001A B.- 600 VAC, MCB,.MO ORYWELL E001P DRAIN SUMP 2R24-5013, FR 4B PUMP-A-2Gil-C006A 9.

630 VAC, MCB, MO ORYWELL AREA C00 LING UNIT J2R24-5012, FR.1BB:

--2T47-B007B f

10, 600.VAC, MCB : MO ORYWELL RETURN AIR FAN:

2R24-5012, FR 19A 2T47-C001B

11. -600 VAC, MCB, MO RHR SHUTDOHN COOLING SUCTION' 2R24-5011, FR 6C VALVE MOV'2E11-F009-
12l, 600 VAC.'HCB, MO DRYWELL AREA COOLING UNIT 2R24-501), FR.18A-2T47-B007A
  • MCB - ralced case circuit breaker MO - me,gnetic.only TM - therma 1' magnetic HATCH - UNIT 2 3/4 8-22 Amendment No. 109

~

W>

b i

  • sa g f.-

TABLE 3.8.2.6-1 (Continued)

PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURREN1 PROTECTIVE DEVICES

=

DEVICE NUMBER SYSTEH/ COMPONENT AND LOCATION

  • POWERED
13. o00-VAC, MCB, MO ORYWELL RETURN AIR FAN g

2R24-5011. FR 18C 2147-C001A 14, 600 VAC, MCB, MO DRYWELL COOLING UNIT 2R24-5013, FR'3B 2T47-8010A l

15. 600 VAC, MCB, M0 DRYHELL COOLING UNIT 2R24-5014, FR BA -

2T47-B010B 16, :600 VAC, MCB..TM

-DRYWELL COOLING UNIT l

2R24-5013, FR 3B 2T47-B010A l

17. 600 VAC, MCB TM DRYWELL COOLING UNIT 2R24-5014, FR BA 2T47-B010B g.

Type ' 7.:-

1.

208hAC,MCB,MO DRYWELL CHEMICAL DRAIN 1

2R24-5013, FR 110 SUMP PUMP 2G11-C101 2.

-208 VAC, MCB, M0 DRYWELL RETURN AIR FAN 2R24-5012, FR 23C 2T47-C0028 3.

20S VAC, MCB.-M0 DRYWELL RETURN AIR FAN 2R24-5011,.FR 22C 2T47-C002A

-i

HO - magnetic only

-TH -_tnermal magnetic s

i l

L j

g

-HATCH - UNIT 2 3/4 8-23 Amendment No. ~109 ll.

.