Look:110 of 18 g!j Final Status Survey Final Report Phase VI Appendix A9 Survey Unit Release Record 9522-0004, Southeast Site Grounds (Non-Protected Area)

February 2007 C

CYAPCO FINAL STATUS SURVEY RELEASE RECORD SOUTHEAST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9522-0004 Prepared By,; Date: 1I 16o'7 Reviewed By: (Date: /I Approved By: Date: / 20 "7 Telkc uport Mnager Revision 0

SOUTHEAST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9522-0004 RELEASE RECORD TABLE OF CONTENTS

1. SURVEY UNIT DESCRIPTION ...................................................... 3
2. CLASSIFICATION BASIS ................................................................ 3
3. DATA QUALITY OBJECTIVES (DQO) .......................................... 6
4. SURV EY D ESIGN ............................................................................. 9
5. SURVEY IMPLEMENTATION ....................................................... 12
6. SURV EY RESU LTS ........................................................................ 13
7. QUALITY CONTROL .................................................................... 20
8. INVESTIGATIONS AND RESULTS ............................................. 20
9. REMEDIATION AND RESULTS .................................................. 23
10. CHANGES FROM THE FINAL STATUS SURVEY PLAN ...... 24
11. DATA QUALITY ASSESSMENT (DQA) ...................................... 24
12. AN O MA LIE S .................................................................................... 25
13. CO N CLU SION ................................................................................ 25
14. A TTA CH M EN TS ............................................................................. 26 14.1 Attachment 1 - Figures (9 pages including cover) 14.2 Attachment 2 - Scan Results (6 pages including cover) 14.3 Attachment 3 - Laboratory Data (322 pages including cover) 14.4 Attachment 4 - DQA Results (16 pages including covers)

TOTAL 379 Revision 0

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9522-0004 (Southeast Site Grounds (non-protected area) is designated as Final Status Survey (FSS) Class 1 and consists of approximately one thousand three hundred eighty-six square meters (1,386 M 2 ) of uninhabited land and is located approximately eight hundred sixty-four feet (864 ft) from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1). The survey unit is bounded as follows: land Survey Unit 9522-0005 and land Survey Unit 9522-0006 to the north (called north as oriented with the north to south flow of the Connecticut River), land Survey Unit 9522-0002 to the west, land Survey Unit 9522-0001 to the south, and the discharge canal to the east. The survey unit is located along the west boundary of Survey Area 9522. The majority of the survey unit is flat and de-vegetated. This is a result of soil grading in support of previous remediation. The west boundary of the survey unit includes a steep bank for the discharge canal. The survey unit has a moderate slope running from east to west The reference coordinates associated with this survey unit are E008 through E01 1 by S075 through S078 (refer to "HNP License Termination Plan" (LTP) Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification."

The "Classification Basis Summary" conducted for Survey Unit 9522-0004 consisted of:

a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "InitialCharacterizationReport" and the "HistoricSite Assessment Supplement,"

c) Historic and current survey records review, d) Visual inspections and a "walkdown."

A review of the "Initialand Supplemental CharacterizationReports " as well as the previous "ClassificationBasis Summaries'"was performed. Survey Area 9522 includes a former survey area, 9308, that was consolidated into Survey Area 9522 in 2006. This survey area was initially designated as Class 2 during the development of the LTP.

Revision 0 3

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD The source documents, the "Connecticut Yankee Haddam Neck Characterization Report" and "Initial Classification for Survey Areas at Connecticut Yankee", were incorporated by reference in LTP, Revision 0.

Survey Unit 9522-0002 was created in 2006 under Revision 4 of the LTP and was designated as Class 1.

Open land Survey Area 9522 was at one time an area immediately adjacent to the southern boundary of the Radiologically Controlled Area (RCA) and security fences. Initially, only a small section of the north side of the unit was paved, with the remainder of the unit gradually sloping down to the original site elevation. The industrial area was expanded to support plant operations and control exposure to radiation. According to the "Haddam Neck Plant Historic Site Assessment Supplement," plant photos revealed that the area was gradually filled in from approximately 1972 to between 1974 and 1976, with soil that may have originated from on-site sources. The introduction of fill material raised the elevation up to site grade and thereby facilitating a reconfiguration and expansion of the RCA and security protected area. Photos taken in 1976 show that the area was landscaped with grass and small trees and was probably given the name "ball-field" at that time. Over the next several years, additional fill was brought in. By 1987, photos show that half of the survey area was paved and occupied with buildings. It is estimated that the elevation in the survey area may have increased by up to five (5) feet from the original site grade.

Survey Area 9522 was impacted by several radiologically significant events during plant operations. These include the discovery of several discrete sources of elevated activity on the ball-field in March 1980, the spill of radioactive liquid into an uncontrolled drain system in February of 1989 and the discovery of several discrete particles outside of the RCA in 1995. Additionally, a portion of Survey Area 9522 was used as a temporary laydown area for the Steam Generator Lower Assemblies (SGLAs) and the Pressurizer until these components where shipped off-site for disposal in 2001. All of these events occurred in the northern portion of Survey Area 9522.

According to Plant Information Report (PIR) 89-35, a section of Survey Area 9522 was contaminated in February 1989 following the release of radioactive material into an uncontrolled drain in the Spent Fuel Building. The drain discharged directly to an open trench that drained into a marshy area of the site.

Freezing conditions limited the amount of radioactive material that left the protected area. The unanticipated release of radioactive material was identified during a routine radiological surveillance of the site. The area was remediated in 1989 to the established release criteria at the time (1E-5 [tCi/g) and, according to memo CH 89-854, the Chemistry Group initiated a sampling program at the drainage site to monitor activity.

Revision 0 4

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Adverse Condition Report (ACR) 95-0250 states that in 1995, several discrete particles were found outside of the RCA, but within the Industrial Area in Survey Area 9522. In addition, two (2) other areas exhibiting elevated activity were identified in 1997. In all cases, the areas of elevated activity were removed upon discovery.

In May of 2005, a Survey and Sampling Work Plan (SSWP X2. 05-05-008) was developed and implemented to characterize the surface soil in this survey area.

Seventeen (17) soil samples were collected as part of the effort to provide sample data with regard to types and quantities of radioactive material present in the surface soil. The soil samples were analyzed by the on-site laboratory. A review of this sample data shows Cs-137 and Co-60 to be the primary radionuclides of concern, which both isotopes reported at fairly low concentrations.

As part of the groundwater characterization effort, a large number of surface and sub-surface soil samples were taken and analyzed for the full suite of "Hard-to-Detect" (HTD) radionuclides specified in the LTP, Table 2-12, "Radionuclides PotentiallyPresentat Haddam Neck Plant" and as provided in Table 2. In some cases, soil was removed to meet the screening criteria in effect for groundwater dose compliance. No HTD radionuclides were positively identified in concentrations greater than the screening criteria upon completion of these surveys and the restoration of the affected areas using off-site fill. Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates. Based upon the results of the previous surveys, it was determined to be unlikely that HTD radionuclides would be present in any significant concentration. Therefore, none of the soil samples taken as part of this characterization survey were analyzed for HTD radionuclides. Statistical quantities (mean, median and standard deviation) from the 2005 characterization survey conducted under SSWP 05-05-008 are provided in Table 1.

Table 1 - Basic Statistical Quantities for Cs-137 and Co-60 from the 2005 Characterization Survey Cs-137 Co-60 (pCi/g) (pCi/g)

Minimum Value: 6.98E-05 -6.69E-02 Maximum Value: 4.01E+00 1.16E+00 Mean: 9.85E-01 1.60E-01 Median: 3.50E-01 2.1OE-02 Standard Deviation: 1.28E+00 3.52E-01 Revision 0 5

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD The FSS Engineer performed a visual inspection and walk-down during September 2006 to assess the physical condition of the survey unit, evaluate access points, travel paths and identify potentially hazardous conditions.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.

Based upon the identification of radioactive material above the Derived Concentration Guideline Levels (DCGLs), and the need for radiological remediation, it was concluded that there was some probability for residual radioactivity in concentrations greater than the DCGLs, justifying a final survey unit classification of Class 1 (refer to Section 3).

3. DATA QUALITY OBJECTIVES (DQO)

FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparationof Final Status Survey Plan," and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria.

The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9522-0004 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.

Revision 0 6

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity. Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Equation I HiTotal =Hsoil+HExistingGW +HFutureGW The total dose under the LTP criteria is twenty-five (25) mremlyr Total Effective Dose Equivalent (TEDE) from all three (3) components. The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024). Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no buried concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mremlyr TEDE.

Equation 2 19 mrem/yrTotal = 17 mrem/yrsoil + 2 mrem/yrExisting GW+ 0 mrem/yrFuturcGW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.

Revision 0 7

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Table 2 -Radionuclide Specific Base Case Soil DCGLs, Operational DCGLs and Required Minimum Detectable Concentrations (MDCs)

Radionuclide () Base Case Soil Operational DCGL Required MDC DCGL (pC/g) (2) (pC/g) (3) (pC/g) (4)

H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+O1 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.1 OE+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-0 1 Ag-108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu- 152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+01 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Cm-243/244 2.90E+O 1 1.97E+01 1.16E+00 (1) Bold indicates those radionucldies considered Hard to Detect (HTD)

(2) The Base Case Soil DCGL(s) are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE (3) The Operational DCGL is equivalent to achieving seventeen (17) mrem/yr TEDE (4) The required MDC is equivalent to achieving one (1) mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed Revision 0 8

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. Soil samples were collected in 2005 to establish the radiological condition of Survey Unit 9522-0004 for FSS.

Cs-137 and Co-60 were the two (2) gamma emitting radionuclides reported in concentrations with the potential for exceeding the screening criteria. The characterization data were used for the survey design and are provided in Table 1.

Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.

As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.

4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparationof Final Status Survey Plans".

The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

The DQO process determined that both Cs-137 and Co-60 would be the radionuclides of concern in Survey Unit 9522-0004 (refer to Section 3). The characterization survey did not include any HTD radionuclides of concern for this survey unit. Based on other survey data, surrogate DCGLs were not required as part of the survey design for this survey unit via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs". Other radionuclides that were positively identified in concentrations greater than the screening criteria during the performance of this FSS would be evaluated to ensure adequate survey design.

As the survey unit is classified as a Class 1 surface soils area, and discrete, elevated areas of contamination was possible, the application of the Elevated Measurement Comparison (EMC) remained an option.

The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. This approach was conservative since it included background Cs-137 as part of the sample set.

Revision 0 9

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.5 to achieve a relative shift (A/cr) in the range of I and 3. The resulting relative shift was 1.82. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10CFR20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design. The survey design specified sixteen (16) surface soil samples for non-parametric statistical testing. Based upon a review of the historical information and Characterization Survey data, the acquisition of additional judgmental surface soil samples from within this survey unit was deemed unnecessary.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locationsfor FinalStatus Survey." Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 1 area.

Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

Table 3 - Sample Measurement Locations with Associated GPS Coordinates Designation Northing Easting 9522-0004-OO1F 236286.65 669067.63 9522-0004-002F 236286.65 669100.40 9522-0004-003F 236258.26 669051.24 9522-0004-004F 236258.26 669084.01 9522-0004-005F 236258.26 669116.79 9522-0004-006F 236258.26 669149.56 9522-0004-007F 236229.88 669034.85 9522-0004-008F 236229.88 669067.63 9522-0004-009F 236229.88 669100.40 Revision 0 10

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Table 3 - (continued)

Designation Northing Easting 9522-0004-OIOF 236229.88 669133.18 9522-0004-011F 236229.88 669165.95 9522-0004-012F 236299.88 669198.73 9522-0004-013F 236201.49 669051.24 9522-0004-014F 236201.49 669084.01 9522-0004-015F 236201.49 669116.79 9522-0004-016F 236201.49 669149.56 Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Two (2) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function. Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.

The LTP requires a minimum of 5% of the samples taken for non-parametric statistical testing be selected for QC evaluation. The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of one (1) soil sample for "split sample" analysis by the off-site laboratory. This location was selected randomly using the Microsoft Excel "RANDBETWEEN" function.

The LTP specifies a required scanning coverage of 100% for outdoor Class 1 areas.

For this Class 1 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 4 provides a synopsis of the survey design.

Revision 0 I1I

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Table 4 - Synopsis of the Survey Design Feature Design Criteria Basis Survey Unit Land Area 1,386 m2 Based on AutoCAD-LT Type 1 and Type 2 errors were 16 0.05, sigma was 0.27 pCi/g, the Number of Measurements (16 systematic grid) LBGR was set at 0.5 to achieve a Relative Shift in the range of 1 and 3 Grid Spacing 11.03 m Based on triangular grid 5.38 pCi/g Cs-137 Administratively set to achieve Operational DCGL 2.59 pCi/g Co-60 17 mremlyr TEDE ()

5.38 pCi/g Cs-137 The Operational DCGL meets Soil Investigation Level 2.59 pCi/g Co-60suvyni the LTP criteria for a Class 1 survey unit Scan Survey Area Approximately The LTP requires coverage for Class100% area 1 survey Coverage 100% of the area units units An instrument Based upon a Minimum response greater Detectable Count of 1,597 cpm Rate and(MDCR) a Scan Investigation Level than the Scan on MD7scan o MDC(DGLEM) Of corresponding MDCsan Of MDC(DCGLEMc) of 7 pCi/g Cs-137 and 1.83 pCi/g 3,108 cpm Co-60 (1) The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)

5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0047. The WP&IR package included a detailed FSS plan, job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

A single scan area was established that constituted approximately 100% of the surface area of Survey Unit 9522-0004. Grid lines, one (1) meter wide, were painted on the ground of the scan area. A background survey was performed around the survey unit and it was determined that, using an Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 5,630 counts per minute (cpm) up to 13,700 cpm.

Revision 0 12

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD The scan area was established and scanned for elevated readings (see Attachment 2 for all scan results). Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second. Approximately 100% of the survey unit was scanned.

Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification. At each sample location, a one (1) meter radius around the sample flag or paint mark was scanned for elevated radiation levels.

Sixteen (16) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."

Two (2) samples (9522-0004-004F and 9522-0004-007F) were randomly selected for HTD radionuclide analysis.

The implementation of survey specific quality control measures included the collection of one (1) sample (9522-0004-001F) for "split sample" analysis.

6. SURVEY RESULTS All field survey activities were conducted between November 22, 2006 and November 29, 2006.

The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels. Table 5 provides an overview of the scan results for sample measurement locations. Scan results are provided in Attachment 2.

Table 5 - Scan Results for Sample Measurement Locations Sample Highest Logged Action Level (2)

Measurement Reading (kcpm) > Action Level (2)

Location (kcpm) 1 7.64E+03 8.61E+03 NO 2 5.93E+03 7.89E+03 NO 3 8.57E+03 1.03E+04 NO 4 6.26E+03 8.30E+03 NO Revision 0 13

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Table 5 - (continued)

Sample Highest Logged Action Level (1)

Measurement Reading > Action Level (2)

Location (kcpm) (cpm) 5 5.65E+03 6.70E+03 NO 6 6.34E+03 8.02E+03 NO 7 1.09E+04 9.49E+03 YES 8 7.99E+03 9.76E+03 NO 9 8.05E+03 9.36E+03 NO 10 5.56E+03 7.08E+03 NO 11 1.24E+04 1.32E+04 NO 12 5.71E+03 6.68E+03 NO 13 9.62E+03 9.44E+03 YES 14 9.69E+03 1.02E+04 NO 15 6.82E+03 7.18E+03 NO 16 1.50E+04 1.41E+04 YES kL) I ne action Level is oased on a measurement above amnment oacKgrouna in accordance with the FSS plan (2) The FSS plan requires movement of the sample measurement location to the area within the 1 meter radius yielding the response above the action level. Sample locations 9522-0004-007F, 9522-0004-013F and 9522-0004-016F were moved accordingly.

The scan areas, that comprised approximately 100% of the total surface area for the survey unit, were scanned for elevated radiation levels. The areas were scanned in accordance with the FSS plan on November 22, 2006 through November 29, 2006. Several elevated measurement locations were identified during scanning. Table 6 provides an overview of the scan area survey. Scan results are provided in Attachment 2.

Revision 0 14

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Table 6 - Scan Area Results Highest Action Logged Level () Elevated Reading Investigation Scan Strips Reading Identification (2) Sample (kcpm) (kcpm) 9522-04-ER-00-01-1 9522-0004-0171 9522-04-ER-00-01-2 9522-0004-0181 9522-04-ER-00-04-1 9522-0004-0191 9522-04-ER-00-04-2 9522-0004-0201 1 thru 10 16.20 7.27 9522-04-ER-00-08-1 9522-0004-0211 9522-04-ER-00-09-1 9522-0004-0221 9522-04-ER-00-09-2 9522-0004-0231 9522-04-ER-00-10-1 9522-0004-0241 9522-04-ER-00-10-2 9522-0004-0251 9522-04-ER-00-19-1 9522-0004-0261 11 thru 20 9.76 9.55 9522-04-ER-00-20-1 9522-0004-0271 9522-04-ER-00-22-1 9522-0004-0281 9522-04-ER-00-23-1 9522-0004-0291 21 thru 30 10.20 8.19 9522-04-ER-00-26-1 9522-0004-0301 9522-04-ER-00-30-1 9522-0004-0311 9522-04-ER-00-32-1 9522-0004-0321 9522-04-ER-00-34-1 9522-0004-0331 31 thru 40 11.00 10.40 9522-04-ER-00-40-1 9522-0004-0341 9522-04-ER-00-40-2 9522-0004-0351 Revision 0 15

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Table 6 - (continued)

Highest Action Logged Level (1) Elevated Reading Investigation Scan Strips Reading Identification 2)Sample (kcpm) (kcpm) 9522-04-ER-00-41-1 9522-0004-0361 9522-04-ER-00-44-1 9522-0004-0371 9522-04-ER-00-45-1 9522-0004-0381 9522-04-ER-00-46-1 9522-0004-0391 41 thru 50 15.90 13.70 9522-04-ER-00-46-2 9522-0004-0401 9522-04-ER-00-47-1 9522-0004-0411 9522-04-ER-00-47-2 9522-0004-0421 9522-04-ER-00-48-1 9522-0004-0431 9522-04-ER-00-49-1 9522-0004-0441 9522-04-ER-00-53-1 9522-0004-0451 9522-04-ER-00-56-1 9522-0004-0461 9522-04-ER-00-56-2 9522-0004-0471 51 thru 60 16.30 14.00 9522-04-ER-00-57-1 9522-0004-0481 9522-04-ER-00-58-1 9522-0004-0491 9522-04-ER-00-60-1 9522-0004-0501 61 thru 65 14.30 13.70 9522-04-ER-00-61-1 9522-0004-051I (1) The action level is based on a measurement above ambient background (2) ER and SC are abbreviations associated with the barcodes used in the field where ER stands for Elevated Reading and SC stands for Scan The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC. The laboratory analyzed the sixteen (16) samples collected for non-parametric statistical testing, the associated field splits and the thirty-five (35) investigative samples using gamma spectroscopy.

Gamma spectroscopy analysis was performed to the required MDCs. Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two (2) standard deviations uncertainty).

However, Cs-137 and Co-60 were the only gamma-emitting radionuclides reported in concentrations exceeding the de-selection criteria.

Revision 0 16

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Cs-137 was identified in eleven (11) and Co-60 was identified in four (4) of the sixteen (16) samples collected for non-parametric statistical testing. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-137 was present at levels lower than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063. A summary of the sixteen (16) samples collected for non-parametric statistical testing results is provided in Table 7.

Table 7 - Summary of Gamma Spectroscopy Results for Surface Soil Samples Comprising the Statistical Sample Population Cs-137 Co-60 Sample Number pCi/g pCi/g 9522-0004-0OlF 4.79E-02 1.84E-02 9522-0004-002F 7.78E-02 1.60E-02 9522-0004-003F 0.OOE+00 -3.62E-03 9522-0004-004F 4.30E-02 1.57E-02 9522-0004-005F -3.1OE-03 5.1OE-03 9522-0004-006F 9.48E-02 -5.83E-03 9522-0004-007F 1.46E-02 1.89E-02 9522-0004-008F 8.05E-02 1.57E-02 9522-0004-009F 5.56E-02 -3.76E-03 9522-0004-OIOF 7.50E-02 0.OOE+00 9522-0004-01IF 1.82E-02 3.62E-02 9522-0004-012F 4.19E-02 2.04E-02 9522-0004-013F 4.47E-02 7.30E-03 9522-0004-014F 4.61 E-02 -1.30E-02 9522-0004-015F 1.03E-01 0.OOE+00 9522-0004-016F -3.90E-03 -1.72E-02 The off-site laboratory also processed two (2) samples for HTD analyses as required by the sample plan. The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses performed met the required minimum MDC.

Revision 0 17

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Sr-90 was positively identified (i.e., a result greater than two (2) standard deviations uncertainty) in both of the two (2) samples analyzed for HTD radionuclides. As previously stated in Section 4 of this report, the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates. For Sr-90, the Operational DCGL is 1.05 pCi/g to achieve a TEDE of seventeen (17) mrem/yr. The analytical results for Sr-90 in the two (2) samples selected for HTD analysis respectively equated to 3% and 18% of the Operational DCGL. Subsequently, Sr-90 was added as a radionuclide of concern for this survey unit. In response, all samples that comprised the statistical sample population for this survey unit were subjected to additional analysis for the presence of Sr-90. The results are provided below in Table 8.

Table 8 - Summary of Sr-90 Analysis Results for Surface Soil Samples Comprising the Statistical Sample Population Sample Number Sr-90 pCi/g 9522-0004-00IF 1.97E-02 9522-0004-002F 8.04E-02 9522-0004-003F 2.36E-02 9522-0004-004F 3.50E-02 9522-0004-005F -2.34E-02 9522-0004-006F 2.84E-03 9522-0004-007F 1.90E-01 9522-0004-008F 3.68E-02 9522-0004-009F 3.43E-02 9522-0004-OIOF 1.90E-02 9522-0004-01 IF 2.96E-02 9522-0004-012F 1.96E-02 9522-0004-013F -3.80E-04 9522-0004-014F 1.95E-02 9522-0004-015F 3.59E-02 9522-0004-016F 6.75E-03 Revision 0 18

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD The "sum-of-fractions" or "unity rule" is the mathematical test used to evaluate compliance with radiological criteria for license termination when more than one radionuclide has been determined to be potentially present. The unity rule is:

Equation 3 Cl C2 C, <1 DCGL, DCGL2 DCGL, Where: Cn = concentration of radionuclide n and DCGLn = DCGL of radionuclide n.

The results of the unity rule calculation for the radionuclides of concern in the statistical sample population for Survey Unit 9522-0004 are provided in Table 9 below.

Table 9 -Results of Unity Calculation for Surface Soil Samples Comprising the Statistical Sample Population Sample Number Fraction of the Operational DCGL(')(2) Unity Cs-137 Co-60 Sr-90 9522-0004-OOIF 0.01 - 0.01 9522-0004-002F 0.01 - 0.08 0.09 9522-0004-003F - - 0.02 0.02 9522-0004-004F 0.01 0.01 0.03 0.05 9522-0004-005F - - - 0.00 9522-0004-006F 0.02 - 0.02 9522-0004-007F - - 0.18 0.18 9522-0004-008F 0.01 0.01 0.04 0.06 9522-0004-009F 0.01 - 0.03 0.04 9522-0004-OIOF 0.01 - - 0.01 9522-0004-OIIF - 0.01 0.03 0.04 9522-0004-012F 0.01 0.01 - 0.02 9522-0004-013F 0.01 - - 0.01 9522-0004-014F 0.01 - 0.02 0.03 Revision 0 19

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Table 9 -(continued)

Sample Number Fraction of the Operational DCGL(')( 2) Unity Cs-137 Co-60 Sr-90 9522-0004-015F 0.02 0.03 0.05 9522-0004-016F - - -

(1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137, 2.59 pCi/g for Co-60 and 1.05 pCi/g for Sr-90 to achieve seventeen (17) mrem/yr TEDE respectively.

(2) - indicates that the radionuclide was not positively detected in the sample

7. QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. One sample location was selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey". Cs-137 was detected in sufficient quantities in both samples to evaluate in accordance with procedure. There was acceptable agreement between the field split results.

The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to Attachment 4 for data and data quality analysis results

8. INVESTIGATIONS AND RESULTS Thirty-five (35) investigative surface soil samples were collected from scan areas exhibiting elevated scan readings. The investigative soil samples were analyzed for Cs-137 and Co-60 in accordance with the DQOs used during the survey design.

As previously stated, Sr-90 was positively identified (i.e. a result greater than two (2) standard deviations uncertainty) in the two (2) surface soil samples selected for HTD analysis. Consequently, Sr-90 was added as a radionuclide of concern for this survey unit. All surface soil samples comprising the statistical sample population were subjected to additional analysis for the presence of Sr-90. Subsequently, the statistical sample population as a whole was evaluated to assess the distribution of the detected radionuclides of concern. The radionuclide distribution percentage for each sample in the population was calculated by dividing the concentration of each detected radionuclide by the total activity concentration in the sample, expressing the abundance of the specific nuclide in the sample compared against the total activity. The mean radionuclide distribution was then calculated by taking the average of the individual sample distribution fractions. The resultant distribution fractions are presented in Table 10 below.

Revision 0 20

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Table 10 - Radionuclide Distribution Fraction for the Radionuclides of Concern in the Statistical Soil Sample Population Detected Radionuclide Distribution Fraction Cs-137 0.592 Co-60 0.083 Sr-90 0.325 The potential presence of Sr-90 in the investigative samples taken that were not subjected to direct analysis for Sr-90 was addressed by using a surrogate relationship to another detectable radionuclide as recommended in NUREG-1575 (MARSSIM), in this case Cs-137. To demonstrate compliance with the release criteria by directly comparing the individual investigative sample results with the DCGL(s) as required by MARSSIM, the DCGL for the surrogate radionuclide, in this case Cs-137 was scaled to account for the fact that it was being used as an indicator for additional radionuclides, in this case Sr-90. This result is referred to as the surrogate DCGL.

The surrogate DCGL was computed based on the distribution ratio between the hard-to-detect radionuclides and the easy-to-detect radionuclides. The surrogate DCGL is computed as follows:

Equation 4 Surrogate~ccl, - [(D . .. ..

1 CG ~~*~ DGJ 3 ..

Where: DCGLSur = Surrogate radionuclide DCGL DCGL 2,3 ...n = DCGL for radionuclides to be represented by the surrogate R, = Ratio of concentration (or nuclide mixture fraction) of radionuclide "n" to surrogate radionuclide Using the DCGLs presented in Table 2 and the soil nuclide distribution presented in Table 10, the following surrogate calculation was deduced; Equation 5 SurrogateoCL=Cs 137) =1.41 pCi/g 5.8Il-)1+ j .3205s-(5.38(Cs-137) + 1.05(sr-90),)

Revision 0 21

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Subsequently, the surrogate DCGL that was used for Cs-137 in this survey unit for direct comparison of investigative sample results to demonstrate compliance with the operational dose limit of seventeen (17) mrem per year is 1.41 pCi/g.

The samples are denoted as shown in Table 6, with the sample results shown in Table 11 below.

Table 11 - Confirmatory Sample Results Sample Number Cs-137 P igP Co-60 ig()2 Unity (I)(2)

Fraction

__________pCi/g pCi/g 9522-0004-0017-I 1.99E-01 3.91E-02 0.141 9522-0004-0018-I 8.83E-02 -4.18E-03 0.063 9522-0004-0019-I 1.06E-01 -1.66E-02 0.075 9522-0004-0020-I 8.1 8E-02 1.33E-02 0.058 9522-0004-0021-I 5.02E-03 -8.99E-03 -

9522-0004-0022-I -1.92E-03 2.23E-02 0.007 9522-0004-0023-I -9.20E-03 -6.50E-03 -

9522-0004-0024-I 1.60E-02 1.15E-03 9522-0004-0025-I 2.42E-02 6.90E-03 -

9522-0004-0026-1 4.99E-02 -9.36E-04 0.035 9522-0004-0027-I 5.61E-02 2.82E-02 0.040 9522-0004-0028-I 9.51 E-02 4.06E-02 0.067 9522-0004-0029-I 1.43E-02 -2.23E-02 -

9522-0004-0030-I 2.17E-02 -2.80E-02 9522-0004-0031-I 5.19E-03 1.37E-02 -

9522-0004-0032-I -1.06E-03 2.82E-02 -

9522-0004-0033-I -4.94E-03 4.14E-03 9522-0004-0034-I 4.04E-03 -2.46E-02 -

9522-0004-0035-I 5.41E-02 3.43E-03 0.038 9522-0004-0036-I 2.63E-02 6.25E-03 0.019 9522-0004-0037-I 1.23E-0 1 3.35E-02 0.100 9522-0004-0038-I 3.65E-02 5.12E-02 0.020 Revision 0 22

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Table 11 - (continued)

Cs-137 Co-60 Unity Fraction Sample Number pCi/g pCi/g (1) (2) 9522-0004-0039-I 4.06E-02 -6.38E-03 -

9522-0004-0040-I 7.66E-02 3.41E-03 0.054 9522-0004-0041-I 6.75E-02 -9.28E-03 0.048 9522-0004-0042-I 2.94E-02 2.87E-03 0.021 9522-0004-0043-I -1.74E-02 4.26E-02 -

9522-0004-0044-I 2.61E-02 -6.71E-03 -

9522-0004-0045-I 2.66E-0 1 6.43E-03 0.189 9522-0004-0046-I 2.45E-02 -8.21E-03 -

9522-0004-0047-I 2.04E-02 2.3 1E-03 -

9522-0004-0048-I 3.03E-02 5.58E-03 0.021 9522-0004-0049-I 1.81E-03 1.26E-02 -

9522-0004-0050-I 8.28E-04 3.43E-03 9522-0004-0051-I 8.40E-03 1.73E-02 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 to achieve seventeen (17) mrem/yr TEDE respectively. The Operational DCGL for Cs-137 has been adjusted to 1.41 pCi/g as a surrogate to account for the potential presence of HTD radionuclide Sr-90.

(2) - indicates that no radionuclides were positively detected in the sample

9. REMEDIATION AND RESULTS Significant remediation activities occurred in this survey unit prior to FSS. All above grade and below grade commodities and facility systems were removed and properly dispositioned. Contaminated soils were identified, excavated and removed as part of the "Zone 12" and "Excavation 7" remediation projects which occurred in this survey area. All excavations were characterized and backfilled with "clean" fill prior to performing FSS. As a byproduct of remediation activities, the ground area is comprised of barren dirt with no vegetation, and the soils have been graded relatively flat to the corresponding elevation of the survey units to the north and east.

Revision 0 23

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN Additional evaluation to account for the presence of Sr-90 was performed on the statistical survey population as a consequence of the results from the initial samples selected for HTD analysis. This was to ensure that the dose consequence from the possible presence of Sr-90 in the surface soils in this survey unit was adequately addressed.
11. DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "DataQuality Assessment, " for completeness and consistency. The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 1.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.

Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs. The basic statistical quantities for the statistical sample population are provided below in Table 12.

Table 12 - Basic Statistical Quantities for Cs-137, Co-60 and Sr-90 from the Final Status Survey Cs-137 Co-60 Sr-90 pCi/g pCi/g pCi/g DCGLop: 5.38E+00 2.59E+00 1.05E+00 Minimum Value: -3.90E-03 -1.72E-02 -2.34E-02 Maximum Value: 1.03E-01 3.62E-02 1.90E-01 Mean: 4.60E-02 6.89E-03 3.3 1E-02 Median: 4.54E-02 6.20E-03 2.17E-02 Standard Deviation: 3.42E-02 1.42E-02 4.74E-02 Revision 0 24

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD The range of the data, about three (3) standard deviations for Cs-137 and about

ýfour (4) standard deviations for Sr-90, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected and the difference between the mean and median was about 2% and 24% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates a slight positive skewness as confirmed by the calculated skew of 0.01 for Cs-137 and 2.65 for Sr-90.

Co-60, although included in the FSS plan for compliance purposes, was positively identified in only four (4) of the sixteen (16) samples collected for non-parametric statistical testing. Assessment of the basic statistical quantities and graphical representation of Co-60 was not considered useful given the limited number of data points to represent the distribution.

All data, assessments, and graphical representations are provided in Attachment 4.

12. ANOMALIES As part of the survey design, two (2) surface soil samples were selected at random for additional analysis for HTD radionuclides. Surface soil sample number 9522-0004-004F was one (1) of the samples selected. The initial analysis results for sample 9522-0004-004F indicated a Sr-90 concentration of 1.26 pCi/g.

This sample result was considered suspect due to the fact that this singular observed concentration was significantly higher than the Sr-90 concentrations previously observed in this and adjacent survey units. In addition, the Minimum Detectable Activity (MDA) of 0.053 pCi/g was approximately twice the previous typical observed MDA for Sr-90 analysis.

Subsequently, the sample analysis vendor, General Engineering Laboratories was instructed to prepare and re-analyze sample 9522-0004-004F for Sr-90. The Sr-90 concentration of 0.035 pCi/g reported from the second analysis, which more closely approximates other Sr-90 sample results, was used as the Sr-90 result for this sample.

13. CONCLUSION Survey Unit 9522-0004 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison was not required.

All identified radionuclides of concern were used for statistical testing to determine the adequacy of the survey unit for FSS.

The sample data passed the Sign Test. The null hypothesis was rejected. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly designated as Class 1.

Revision 0 25

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD The dose contribution from soil is 0.726 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no underground structures, systems or components containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, the dose contribution from future groundwater is zero (0) mremlyr TEDE.

The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 2.726 mrem/yr TEDE. Therefore, Survey Unit 9522-0004 is acceptable for unrestricted release.

14. ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 26

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD ATTACHMENT 1 (FIGURES)

Revision 0

I'll "ill oWII 0

  • 0*

q 0

0 0%

I i

9522-0001 9522-0003 9522-0006 002

)005 6011

=WetLand 001 0010

)004 01 6 0009 0003 9522-0005 ,008 015 0014 007 0013 0 is 30 IFan NAD27COwchcur sWVkPhWSyatn ConnecticutYankee Atomic Power Company Sample Location Map for Survey Unit 9522-0004

=sOil Smple RaqlMNi M~ig 9522-0006 00 0.078 WatLaud

~0O0 1106-0002 0.048 0.075 0.043 0.056 0.000 22-0005 0.081 0.103 00 0.046 0.015 0 15 30

- Fd Notu Cooidundw am in NAD27CbMKeciicu Icy s iaw k oW PowerCompany FinalStatus Survey Unit9522-0004 Cesium-137PostingPlot

=Soil SImple Result in p Cig 9522-0006 00 0.016 = Wet La*d 106-0002 0.005 0.018 0.000 0.016

~004 0.004 9522-0005 00 0.016 0.000 00

-0.013 00 0.019 Not-s 0 15 30)

NOMFs Coestelams mWin NAD27Conmeclku StAftPlan Sstsu mnecticut Yankee Atomic PowerCompany FinalStatus Survey Unit 9522-0004 Cobalt-60PostingPlot

I, w22-0003

-Soil Sampl Rcnt in p Ci/g 9522-0006 0.080 - Wd Land 00

-0.023 106-0002 0.020 0.019 0.035 0 0.034 0.024 9522-0005 00 0.037 0.036 0.020 0.190 0 - is 30 Ceriowhm m i PN4D27Cbmdu sawplowsyt FinalStatus Survey Unit9522-0004 Strontium-90Posting Plot

9522-0001 I9522-0003 9522-0006

= 3-*zo~

046 F,-- WetLasd 0260 0027 029 030 9522-0005044 031 C,

0 0 0032 033 M4D27Cb-*kut kI~Ph~y Connecticut Yankee Atomic Power Company C3 Aga invesogtive Sample LocationMap for Survey Unit

W2-0003

=sOISaMp~c Rcsnltni2P Mg 9522-0006 106-0002 IP"~ - e= n 0.266 122.00050.026 15I 30 NAD27CmIwdiaM Connecticut Yankee Atomic PowerCompany Cy FinalStatus Survey Unit9522-0004 InvestigativeSample Cesium-137PostingPlot

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)

Revision 0

SOUTHEAST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9522-0004 RELEASE RECORD Attachment 2 SCAN RESULTS @ SAMPLE LOCATIONS Survey Location Log Date Log Time Reading Alarm Level >Alarm E-600 S/N Probe S/N Level 9522-04-BL-00-01-0 11/22/2006 7:25:00 7.38E+03 1114 1014 9522-04-SL-00-01-0 11/22/2006 7:26:00 7.64E+03 8.61E+03 1114 1014 9522-04-BL-00-02-0 11/22/2006 7:27:00 6.72E+03 114 1014 9522-04-SL-00-02-0 11/22/2006 7:27:00 5.93E+03 7.89E+03 1114 1014 9522-04-BL-00-03-0 11/22/2006 7:28:00 8.94E+03 1114 1014 9522-04-SL-00-03-0 11/22/2006 7:29:00 8.57E+03 1.03E+04 1114 1014 9522-04-BL-000470 1/22/2006 7:30:00 7.10E+03 1104 1014 9522-04-SL-00-04-0 11/22/2006 7:30:00 6.26E+03 8.30E+03 1114 1014 9522-04-BL-00-05-0 11/22/2006 7:40:00 5.63E+03 114 1014 9522-04-SL-00-05-0 11/22/2006 7:41:00 5.65E+03 6.70E+03 1114 1014 11/22/2006

-9522-04-BL-00-06-0 7:42:00 6.84E+03 1114 1014 9522-04-SL-00-06-0 11/22/2006 7:42:00 6.34E+03 8.02E+03 1114 1014 9522-04-BL-00-07-0 11/22/2006 7:45:00 8.20E+03 1114 1014 9522-04-SL-00-07-0 11/22/2006 7:46:00 1.09E+04 9.49E+03 + 1114 1014 9522-04-BL-00-08-0 11/22/2006 7:47:00 8.45E+03 1114 1014 9522-04-SL-00-08-0 11/22/2006 7:48:00 7.99E+03 9.76E+03 1114 1014 9522-04-BL-00-09-0 11/22/2006 9:38:00 8.08E+03 114 1014, 9522-04-SL-00-09-0 11/22/2006 9:39:00 8.05E+03 9.36E+03 1114 1014 9522-04-BL-00-10-0 11/22/2006 9:40:00 5.98E+03 114 1014 9522-04-SL-00-10-0 11/22/2006 9:41:00 5.56E+03 7.08E+03 1114 1014 9522-0 14-BL-0 .0-11-0 11/2212006 9:41:00 1.117E+04 1114 1014 9522-04-SL-00-11-0 11/22/2006 9:42:00 1.24E+04 1.32E+04 1114 1014 9522-04-BL-00-12-0 11/22/2006 9:43:00 5.61 E+03 1114 1014 9522-04-SL-00-1 2-0 11/22/2006 9:44:00 5.71 E+03 6.68E+03 1114 1014 9522-04-BL-00-13-0 11/22/2006 10:11:00 8.15E+03 1114 1014 9522-04-SL-00-1 3-0 11/22/2006 10:12:00 9.62E+03 9.44E+03 + 1114 1014

9522-04-BL-00-14-0 11/22/2006 10:13:00 8.82E+03 1114 1014 9522-04-SL-00-14-0 11/22/2006 10:14:00 9.69E+03 1.02E+04 1114 1014 9522-04-BL-00-1 5-0 11/22/2006 10:14:00 6.07E+03 1114 10.141 9522-04-SL-00-1 5-0 11/22/2006 10:15:00 6.82E+03 7.1 8E+03 1114 1014 9522-04-BL-00-1 6-0 11/2212006 10:15:00 1.25E+04 1114 1014 9522-04-SL-00-1 6-0 11/22/2006 10:16:00 1.50E+04 1.41 E+04 + 1114 1014 REVISION 0 Page I of I

SOUTHEAST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9522-0004 RELEASE RECORD Attachment 2 SCAN RESULTS FOR SCAN STRIPS

>Alarm Survey Location Log Date Log Time Reading Alarm Level E-600 S/N Probe S/N Level 9522-04-BC-00-01 -0 11/271/2006 7:50:00 6.54E+03 1114 1014 9522-04-SC-00-01 -O 11/27/2006 7:58:00 6.09E+03 7.69E+03 1114 1014 9522-04-ER-00-01-1 11/28/2006 7:47:00 7.58E+03 7.69E+03 1114 1014 9522-04-ER-00-012-2 1112812006 7:48:00 8.09E+03 7.69E+03 1114 1014 9522-04-SC-00-03-0 11/27/2006 8:00:00 6.75E+03 1114 1014 9522-04-SC-00-02-0 11/27/2006 8:08:00 6.64E+03 7.92E+03 1114 1014 9522-04-BC-00-03-0 11/27/2006 8:09:00 7.57E+03 1114 1014 9522-04-SC-00-03-0 11/27/2006 8:15:00 6.02E+03 8.81E+03 1114 1014 9522-04-BC-00-04-0 11/27/2006 8:16:00 6.57E+03 1114 1014 9522-04-SC-00-04-0 11/27/2006 8:21:00 6.84E+03 7.73E+03 1114 1014 9522-04-ER-00-04-1 11/28/2006 8:07:00 7.44E+03 7.73E+03 1114 1014 9522-04-ER-0O-04-2 11/28/2006 8:08:00 8.59E+03 7.73E+03 1114 1014 9522-04-BC-00-05-0 11/27/2006 8:22:00 7.32E+03 1114 1014

÷ 9522-04-SC-00-05-0 11/27/2006 8:28:00 6.95E+03 8.54E+03 1114 1014 4.ii*!!!i~ii~*!ii~iii!ii~

9522-04-SC-00-06-0 11/2712006 8:29:00 7.84E+03 1114 1014 9522-04-SC-00-06-0 11/27/2006 8:31:00 7.48E+03 9.12E+03 1114 1014 g522-04-BC-00-07-0 11/27/2006 8:31:00 6.91 E+03 +iiiiiiiiiiiiiiiiiiii*! 1114 1014 9522-04-SC-00-07-0 11/27/2006 8:34:00 7.53E+03 8.5OE+03 1114 1014

+~i~ii;iiii**~:!!!!i!iii!

11/27/2006 08:43:00 7.50E+03 1114 1014 9522-04-EC-00-08-0 11/27/2006 8:45:00 6.34E+03 1114 1014 9522-04-ER-00-08-1 11/28/2006 8:38:00 1.18E+04 1114 1014

.9522-04-BC-00-09-0 11/27/2006 8:46:00 6.1 5E+03 1114 1014 9522-04-SC-00-09-0 11/27/2006 8:48:00 6.56E+03 7.27E+03 1114 1014 9522-04-ER-SC-09-1 11/28/2006 8:38:00 1.42E+04 7.27E+03 1114 1014 9522-04-ER-OO-09-2 11/28/2006 10:03:00 1 .62E+04 7.27 E+03 1114 1014

.9522-04-BC-00-10-0 11/27/2006 8:491:.0:0 7.33E+03 1114 1014 9522-04-SC-00-10-0 11/27/2006 8:52:00 6.49E+03 8.55E+03 1114 1014 9522-04-ER-OO-1 0-1 11/28/2006 10:04:00 1.41 E+04 8.55E+03 1114 1014 9522-04-ER-OO-l 0-2 1112812006 10:26:00 1.42E+04 8.55E+03 1114 1014 9522 -O4-BC-0O-1 1-0 11 /27/2006 9:58:00 7.36E+03 1114 1014 9522-04-SC-00-11-0 11/27/2006 10:00:00 6.67E+03 8.59E+03 1114 1014 11/27/2006 10:01 :00~ 6.65E+03 1114 1014 9522-04.BC-00-1 2-0 11/27/2006 10:04:00 6.94E+03 7.81 E+03 1114 1014 9522-04-SC-00-12-0 11/27/2006 10:05:00 8.291E+0.3 1114 1014 9522. 4.-BC-00-1 3-0 9.59E+03 1114 11/27/2006 10:07:00 6.47E+03 1014 9522-04-SC-0O-1 3-0 11/27/2006 10:11:00 .6.84E+03. 1114 1014:

.9522-04-BC-00-14-0 8.02E+03 1114 1014 11/27/2006 10: 12:00 6.70E+03

95212-04-SC-00-1 4-0 11/27/2006 10:13:00. 7.85E+03 1114 1014.

9522-04-S C-0O-1 5-0 11/27/2006 10:15:00 6.27E+03 9.12E+03 1114 1014

.9522-04-BC-00-16-0 11/27/2006 10:16:00 7.95E+0.3 1114 1014 9522-04-SC-00-1 6-0 11/27/2006 10:17:00 7.29E+03 9.22E+03 1114 1014 0522-04-BC-00-1 7-0 11/27/2006 10:18:00 8.42E+03 1114 1014 9522-04-SC-00-1 7-0 11/27/2006 10:21 :00 6.38E+03 9.73E+03 1114 1014 REVISION 0 Page]1 of 4

SOUTHEAST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9522-0004 RELEASE RECORD Attachment 2 Survey Location Log Date >Alarm Log Time Reading Alarm Level E-600 SIN Probe SIN Level 9522-04-BC-00-18-0 11/27/2006 10:22:00 7.84E+03 1114 1014 9522-04-SC-00-18-0 11127/2006 10:26:00 7.14E+03 9.1 OE+03 1114 1014 9522-04-EC-00-19-0 11127/2006 10:27:00 8.25E+03 1114 1014 9522-04-SC-00-19-0 11127/2006 10:31:00 9.06E+03 9.55E+03 1114 1014 9522-04-ER-00-29-1 11/28/2006 10:27:00 9.76E+03 9.55E+03 4- 1114 1014 9522-04-BC-00-20-0 11/27/2006 10:31:00 1.OOE+04 1114 1014 9522-04-SC-00-20-0 11/27/2006 10:36:00 7.52E+03 1114 1014 9522-04-ER-00-20-1 11/28/2006 10:48:00 8.21E+03 1114 1014 9522-04-BC-00-21-0 11/2712006 10:36:00 8.75E+03 1114 1014 9522-04-SC-00-21-O 11/27/2006 10:39:00 7.90E+03 1.01 E+04 1114 1014 9522-04-BC-00-22-0 11/27/2006 10:40:00 7.75E+03 1114 1014 9522-04-SC-00-22-0 11/27/2006 10:42:00 8.63E+03 9.01 E+03 1114 1014 9522-04-ER-00-22-1 11/28/2006 10:49:00 9.23E+03 1114 1014 9522-04-BC-00-23-0 11/27/2006 10:43:00 8.53E+03 1114 1014 9522-04-SC-00-23-0 11127/2006 10:46:00 9.04E+03 9.85E+03 1114 1014 9522-04-ER-00-23-1 11/28/2006 11:06:00 1.23E+04 1114 1014 1.9522-04-13C 100-24-0 11127/2006 10:46:00 8.64E+03 1114 1014 9522-04-SC-00-24-0 11/27/2006 10:48:00 9.13E+03 9.97E+03 1114 1014

,9522-04-BC-00-25-0 11/27/20 ,06 10:50:00 8.48E+03 1114 1014 9522-04-SC-00-25-0 11/27/2006 10:51 :00 6.96E+03 9.80E+03 1114 1014 9522-04-BC-00-26-0 11/27/2006 10:51:00 7.35E+03 1114 1014 9522-04-SC-00-26-0 11/27/2006 10:54:00 8.38E+03 8.57E+03 1114 1014 9522-04-ER-00-26-0 11/28/2006 11:07:00 8.55E+03 8.57E+03 1114 1014 9522-04-ER-00-26-I 11/28/2006 11:08:00 8.27E+03 8.57E+03 1114 1014 9522-04-BC-00-27-0 11/2712006 10:55:00 8.88E+03 1114 1014 9522-04-SC-00-27-0 11/27/2006 10:56:00 6.50E+03 1.02E+04 1114 1014 11/27/2006 10:57:00 7.72E+03 1114 1014 9522-04-EC-00-28-0 11/27/2006 10:59:00 7.77E+03 8.97E+03 1114 1014

,9522-04-BC-00-29-0 11/27/2006 11:00:00 7.95E+03 1114 1014 9522-04-oC-0O-29-0 11/27/2006 11:01:00 7.20E+03 9.22E+03 1114 1014 9522-04-SC-00-33-0 11/27/2006 11:02:00 7.OOE+03 1114 1014 9522-04-SC-00-30-0 11/27/2006 11:04:00 7.84E+03 8.1 9E+03 1114 1014 9522-04-ER-00-30-1 11/28/2006 11:25:00 1.02E+04 8.19E+03 4- 1114 1014 9522-04-BC-00-31-0 11/27/2006 11:06:00 8.66E+03 1114 1014 9522-04-SC-00-31 -O 11/27/2006 11:08:00 6.94E+03 9.99E+03 1114 1014 9522-04-BC-00-32-0 11/27/2006 11:08:00 8.38E+03 1114 1014 9522-04-SC-00-32-0 11/27/2006 11:11:00 8.88E+03 9.69E+03 1114 1014 9522-04-ER-00-32-I 11/28/2006 11:25:00 1.02E+04 9.69E+03 + 1114 1014

..9522-04-BC-0033-0 11/27/2006 11:12:00 9.35E+03 1114 1014 9522-04-SC-O0-33-0 11/27/2006 11:13:00 8.50E+03 1.07E+04 1114 1014 9522-04-BC-00-34-0 11/27/2006 11:14:00 8.45E+03 1114 1014 9522-04-SC-00-34-0 11/27/2006 11:16:00 9.21 E+03 9.76E+03 1114 1014 9522-04-ER-00-34-1 11/28/2006 13:11:00 1.01E+04 9.76E+03 4-1114 1014 9522-04-BC-0.0-35-0 11/27/2006 11:17:00 9.13E+03 1114 1014 9522-04-SC-00-35-0 11/27/2006 11:18:00 8.50E+03 1.05E+04 1114 1014 REVISION 0 Page 2 of 4

SOUTHEAST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9522-0004 RELEASE RECORD Attachment 2

>Alarm Survey Location Log Date Log Time Reading Alarm Level E-600 S/N Probe S/N Level

,9522-014-BC-0 ,0-36-0 11/27/2006 11:19:00 8.81 E+03 1114 1014 9522-04-SC-00-36-0 11/27/2006 11:20:00 9.70E+03 1.02E+04 1114 1014

.9522-04-BC-00-37-0 11/27/2006 13:17:00 7.60E+03 1114 1014 9522-04-SC-00-37-0 11/2712006 13:28:00 7.53E+03 8.84E+03 1114 1014

§522-04-9,C-00-3 I -0 11127/2006 13:29:00 .8.12E+03 1114 1014 9522-04-SC-00-38-0 11/27/2006 13:30:00 8.95E+03 9.41 E+03 1114 1014 9522-04-13C-00-39-0 I11027100.6 13:30:00 9.96E+03 1114 1014 9522-04-SC-00-39-0 11/27/2006 13:31:00 9.56E+03 1.14E+04 1114 1014 9522-04-BC-00-40-0 1112712006 13:31:00 9.07E+03 1114 1014 9522-04-S C-00-40-0 11/27/2006 13:35:00 9.88E+03 1.04E+04 1114 1014 9522-04-ER-00-40-1 11/28/2006 13:12:00 1.03E+04 1.04E+04 1114 1014 9522 E R-00-40-2 11/28/2006 13:39:00 1.10E+04 1.04E+04 ÷ 1114 1014 9522 BC-00-41 -0 11/27/2006 13:36:00 9.72E+03 1114 1014 9522-04-SC-00-41 -0 11/27/2006 13:41:00 8.59E+03 1.11 E+04 1114 1014 9522-04-ER-00-41 -1 11/28/2006 13:40:00 1.10E+04 1.11E+04 1114 1014

.9522-04-IBC-010-42-0 11/27/2006 13:42:00 1.1It+04 1114 1014 9522-04-SC-00-42-0 11/27/2006 13:43:00 1.02E+04 1.26E+04 1114 1014 9522-04-BC-00-43-0 11/2712006 13:44:00 1 .05E+04 1114 1014 9522-04-SC-00-43-0 11/27/2006 13:45:00 1.12E+04 1.20E+04 1114 1014 9522-04-BC-00-44-0 11/27/2006 13:46:00 8.1 5E+03 1114 1014 9522-04-SC-00-44-0 11/27/2006 13:48:00 8.46E+03 9.44E+03 1114 1014 9522-04-ER-0O-44-1 11/28/2006 13:53:00 8.41 E+03 9.44E+03 1114 1014 9522-04-13C-00-45,0 11/27/2006 13:50:00 9.46E+0 3 1114 1014 9522-04-SC-00-45-0 11/27/2006 13:51:00 9.44E+03 1.08E+04 1114 1014 9522-04-ER-00-45-1 11128/2006 13:54:00 9.53E+03 1.08E+04 1114 1014 9522.04-BC-00 10 11/27V2006 .13:52:00 9.44E+03 1114 1014 9522-04-SC-00-46-0 11/27/2006 13:56:00 9.10E+03 1.08E+04 1114 1014 9522-04-ER-00-46-1 11/28/2006 14:09:00 1.10E+04 1.08E+04 + 1114 1014 9522-04-ER-00-46-2 11/28/2006 14:10:00 1.11 E+04 1.08E+04 + 1114 1014 95221-04-BC-00-47-0 13:57:00 1 .05E+04 1:114 1014, 9522-04-SC-00-47-0 11/27/2006 14:00:00 9.50E+03 1.20E+04 1114 1014 11/27/2006 4.

9522-04-ER-00-47-1 14:30:00 1.24E+04 1.20E+04 1114 1014 11/28/2006 .4.

9522 E R-00-47-2 14:31:00 1.39E+04 1.20E+04 1114 1014 11/28/2006 9522w04-B3C-00-48-0 14:00:00 1.01E+04 1114< 1014 11/27/2006 9522-04-SC-00-48-0 14:02:00 1.05E+04 1.15E+04 1114 1014 11/27/2006 9522-04-ER-00-48-1 14:53:00 1.46E+04 1.15E+04 + 1114 1014 11/28/2006 9522-04-BC-00-49-0 14:04:00 1.21E+04 1114 1014 11/27/2006 9522-04-SC-00-49-0 14:07:00 1.20E+04 1.37E+04 1114 1014 11/27/2006 9522-04-ER-00-49-1 14:54:00 1.59E+04 1.37E+04 + 1114 1014 11/28/2006

.9522-04-13C-00-50-0 14:08:00 8.95E+03 1114 1014 11/27/2006 9522-04-SC-OO-50-0 14:10:00 8.32E+03 1.03E+04 1114 1014 11/27/2006 9522 B C-00-51 -o 14:32:00 7.56E+03 1114 1014 11/27/2006 9522-04-SC-00-51 -0 14:33:00 6.93E+03 1114 1014 11/27/2006 14:34:00 9.1 8E+03 1114 1014 9522-04-BC-00-52-0 11/27/2006 14:34:00 8.74E+03 1.05E+04 1114 1014 REVISION 0 Page 3 of 4

SOUTHEAST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9522-0004 RELEASE RECORD Attachment 2 Survey Location Log Date Log Time Reading Alarm Level >Alarm E-600 SIN Probe SIN Level 9522-04-BC-00-53-0 1112712006 14:38:00 19.06E+04 1114 1014 9522-04-SC-00-53-0 11/27/2006 14:39:00 9.74E+03 1.21 E+04 1114 1014 9522-04-ER-00-53-1 11/29/2006 7:44:00 1.26E+04 1.21E+04 + 1114 1014 9522-04-BC-00-54-0 11/27/2006 14:40:00 8.84E+03 1114 1014 9522-04-SC-00-54-0 11/27/2006 14:41:00 7.85E+03 1.02E+04 1114 1014 9522-04-BC-00-55-0 11/27/2006 14:41:00 9.56E+03 1114 1014 9522-04-SC-00-55-0 11/27/2006 14:42:00 8.41E+03 1.10E+04 1114 1014 9522-04-BC-00-56-0 11/27/2006 14:46:00 1.14E+04 1 + 1114 1014 9522-04-SC-00-56-0 11/27/2006 14:49:00 1.19E+04 1.29E+04 1114 1014 9522-04-ER-00-56-1 11/29/2006 7:45:00 1.39E+04 1.29E+04 + 1114 1014 9522-04-ER-00-56-2 11/29/2006 8:10:00 1.35E+04 1.29E+04 + 1114 1014 9522-04-EC-00-57-0 11/27/2006 14:51:00 1.2638E+4E+04 1114 1014 9522-04-SC-00-57-0 11/27/2006 14:53:00 1.27E+04 1.44E+04 1114 1014 9522-04-ER-00-57-1 11/29/2006 8:11:00 1.41 E+04 1.44E+04 1114 1014 9522-04-BC-00-58-0 11/27/2006 14:54:00 1.24E+04 1114 1014 9522-04-SC-00-58-0 11/27/2006 14:56:00 1.33E+04 1.40E+04 1114 1014 9522-04-ER-00-58-1 11/29/2006 10:09:00 1.63E+04 1.40E+04 + 1114 1014 9522-04-BC-00-59-0....11/27/2006.14:58:00 .1.28E+04. 1114 1014 9522-04-SC-00-59-0 11127/2006 14:59:00 1.31E+04 1.44E+04 1114 1014

.522-04-B C-00-63,0-0 11127/2006 1: 00:00 0: ,0 1 1.3 0E+04 6 1114 1014 9522-04-SC-00-60-0 11/27/2006 15:01:00 1.42E+04 1.46E+04 1114 1014 9522-04-ER-00-60-1 11/29/2006 10:10:00 1.47E+04 1.46E+04 + 1114 1014 1-0 :9522-04-BC-001 11/27/2006 15: 04:0 1.21 E+04 1114 1014 9522-04-SC-00-61-0 11/27/2006 15:05:00 1.23E+04 1.37E+04 1114 1014 9522-04-ER-00-61-1 11/29/2006 10:24:00 1.43E+04 1.37E+04 + 1114 1014 9522-04-BC-00-62-0 11/27/2006 15:06:00 1.28E+04 1114 1014

.9522-04-SC-00-62-0 11/27/2006 15:08:00 1.1 6E+04 1 .44E+04 1114 1014 9522-04-BC-00-63-0 11/27/2006 15:09:00 6.76E+03 1114 1014 9522-04-SC-00-63-0 11/27/2006 15:10:00 5.93E+03 7.93E+03 1114 1014 9512-2-04-B.C-00-64-0 11/27/2006 15:12:00 1.37E+04 1114 1014 9522-04-SC-00-64-0 11/27/2006 15:12:00 1.33E+04 1 .54E+04 1114 1014 9522-04-BC-00-65-0 11/27/2006 15:13:00 7.50E+03 1114 1014 9522-04-SC-00-65-0 11/27/2006 15:15:00 6.08E+03 8.74E+03 1114 1014 REVISION 0 Page 4 of 4

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)

Revision 0

General Narrative 1

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 176890 SDG: MSR#06-1506 December 01, 2006 Laboratory Identification:

General Engineering Laboratories, LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at General Engineering Laboratories, LLC, Charleston, South Carolina on November 30, 2006 for analysis. Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Sample Identification Description 176890001 9522-0004-001 F 176890002 9522-0004-001FS 176890003 9522-0004-002F 176890004 9522-0004-003F 176890005 9522-0004-004F 176890006 9522-0004-005F 176890007 9522-0004-006F 176890008 9522-0004-007F 176890009 9522-0004-008F 176890010 9522-0004-009F 176890011 9522-0004-01 OF 176890012 9522-0004-01 IF 176890013 9522-0004-012F 176890014 9522-0004-013F 176890015 9522-0004-014F 176890016 9522-0004-015F 176890017 9522-0004-016F 176890018 9522-0004-0171 176890019 9522-0004-0181 176890020 9522-0004-0191 176890021 9522-0004-0201 176890022 9522-0004-0211 176890023 9522-0004-0221 176890024 9522-0004-0231 176890025 9522-0004-0241 GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, MC.

P.O. BOX 30712 Charleston, SC 29417

  • 2040 Savage Road (29407)

Phone (843) 556-8171 - Fax243) 766-1178 www.gel.com

176890026 9522-0004-0251 176890027 9522-0004-0261 176890028 - 9522-0004-0271 176890029 9522-0004-0281 176890030 9522-0004-0291 176890031 9522-0004-0301 176890032 9522-0004-0311 176890033 9522-0004-0321 176890034 9522-0004-0331 176890035 9522-0004-0341 176890036 9522-0004-0351 176890037 9522-0004-0361 176890038 9522-0004-0371 176890039 9522-0004-0381 176890040 9522-0004-0391 176890041 9522-0004-0401 176890042 9522-0004-0411 176890043 9522-0004-0421 176890044 9522-0004-0431 176890045 9522-0004-0441 176890046 9522-0004-0451 176890047 9522-0004-0461 176890048 9522-0004-0471 176890049 9522-0004-0481 176890050 9522-0004-0491 176890051 9522-0004-0501 176890052 9522-0004-0511 Items of Note There are no items to note.

Case Narrative Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL)

Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request Fifty soil samples were analyzed for FSSGAM. Two soil samples were analyzed for FSSALL.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417

  • 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax443) 766-1178 www.gel.com

List of current GEL Certifications as of 01 December 2006 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01 151CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SC012 Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C1641 4

Chain of Custody and Supporting Documentation 5

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form N.20.08 Connecticut Yankee Atomic Power Company No. 2006-00685 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab use. Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: [] 30 D.L] 14 D. Z 7 D. [] 3 D. C Sample Size- Lab Sample...

Sample Designation Date Time Media Type &Type Comment, Preservation Lai Sample ID Code Code Code 9522-0004-0 //]0 071o TS G BP  ? - -. --

'*r* -o -u (.~ vFf If/))t i, o72ý 7" }P Y,

"  ;*

qy*2 o. * !T4.i II/ /L J'L, rL....I - L.... - _...-.-.. ,,, , .. ._

qy.)L - 9 ~o~'f.07 6 qi- )*0*.)t j/iI~ o2..... Tr0. .1 14 -... ..

qi)1- ooy~~ct'~

q~~~~)~

-o //;tt,2I, Wo~'io~to+/-4.L C 2i&....

0Y2 U

T2;. .Ž 4,Bc--

7(

_____-

_ _

-______,______._

__

- __ _ _

______________

_ _ _ _ _

_______ ____-7 tlV /1)f A. L~~ c_ __ -

q~j '-o0~ _aba/~lý 3rj z ~ Jf.... .__ __ - _________ ______

NOTES: PO #: 002332 MSR #: 06-,. SSWP# NA X LTP QA LI Radwaste QA LI Non QA Samples Shipped Via: Ifiternal Container ItL5so( E Fed Ex Temp.: Deg.

F- ups C' LI Hand CiistodyySealed?

YE NO

1) Relinquished By Date/Time 2) R ved B ate/Tit he Custody Seal DI Other Intact?
3) Relinquished By Date/Time 4) Received By DateTime YE1 NE1 Bill of Lading #

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Chain of Custody Form N.20-08 Connecticut Yankee Atomic Power Company No. 2006-00686 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab'Use Only Contact Name & Phone: Comnients" Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones Priority: E] 30 D. 1] 14 D. Z 7 D. [] 3 D. C Container [7 i**(**

Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9 5 22 4

-000 - oil p/L 09Vý TS G BP .___

."...........

9oto'i-po.,.a( ,b/" oi! 9jAl c ~ P.......

... .[ - -.

i)- o~?--,"1 oj-f 0/ !2/l I lo 7 L ¢ .2L .. --

_ _ _ojyl _ 1/FA

_ _ /OI _ _j'J

_ _

75) 0- 11b /V 1_ t'_ I__ -)'i - __ _ __ _ ___ _

NOTES: PO #: 002332 MSR#: 06-I,- SSWP# NA Z LTP QA El Radwaste QA F1 Non QA Samples Shipped Via: Intemal Container 1604( Z Fed Ex Termp.: - Deg.

nl UPS C El Hand Custody Sealed?

YO] NO]

1) Relinquished By Custody Seal Date/Time 2) ed By 1 o Date/Tfme 0l Other Intact?
3) Relinquished By Date/Time 4) Received By Date/Time Y 11 N 0 Bill of Lading #

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00687 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Analyses Requested Lab Use Only Decommissioning_

Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State): Code &Type General Engineering Laboratories Code 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority:L] 30 D."] 14 D. N 7 D.

_x_3 Other:

Sample Designation Date Time 4 Comment, Preservation Lab Sample ID 9522-0004-0171 11/28/06 0746 TS G BP X 9522-0004-0181 11/28/06 0748 TS G BP X 9522-0004-0191 11/28/06 0807 TS G BP X 9522-0004-0201 11/28/06 0808 TS G BP X 9522-0004-0211 11/28/06 0838 TS G BP X 9522-0004-0221 11/28/06 0840 TS G BP X 9522-0004-0231 11/28/06 1002 TS G BP X 9522-0004-0241 11/28/06 1004 TS G BP X 9522-0004-0251 11/28/06 1026 TS G BP X 9522-0004-0261 11/28/06 1028 TS G BP X 9522-0004-0271 11/28/06 1048 TS G BP X aseQSamples Shipped Via: Internal Container NOTES: P0 #: 002332 MSR#: :LPQR NOT U#P QA D Radwaste QA Non QA Fed Ex Temp.: __ Deg. C LI Hand Custody Sealed?

YO NO

1) Relinquished By Date/Time 2) Rec if By, Date/Time Custody Seal Intact?

OVe4-eTi~ ID f C Other

3) Relinquished By Date/Time 4) Received By Bil of Late/TimYOD N]

Bill of Lading #

5) Relinquished By Date/Time 6) Received By Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00688 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Analyses Requested Lab Use Only Decommissioning Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State): Code &Type General Engineering Laboratories Code 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones ( 843-556-8171)

Priority:E] 30 D.[] 14D. [ 7D.

Other:

Sample Designation Date Time I Comment, Preservation Lab Sample ID 9522-0004-0281 11/28/06 1050 TS G BP X 9522-0004-0291 11/28/06 1106 TS G BP X 9522-0004-0301 11/28/06 1108 TS G BP X 9522-0004-0311 11/28/06 1125 TS G BP X 9522-0004-0321 11/28/06 1126 TS G BP X 9522-0004-0331 11/28/06 1312 TS G BP X 9522-0004-0341 11/28/06 1314 TS G BP X 9522-0004-0351 11/28/06 1340 TS G BP X 9522-0004-0361 11/28/06 1342 TS G BP X 9522-0004-0371 11/28/06 1355 TS G BP X 9522-0004-0381 11/28/06 1357 TS G BP X Samples Shipped Via: Internal Container NOTES: PO #: 002332 MSR#: 04i" - L, LTPQA LI RadwasteQA ["I NonQA S FedEx Temp.: Deg. C El UPS Dl Hand Custody Sealed?

YO NO]

1) Relinquished By Date/Time 2) Rec vdBy Date/Time:O Custody Seal Intact?
3) Relinquished By Date/Time 4) Received By Date/Time BillofLading_# Yo Nfl
5) Relinquished By .."Date/Time Bill of Lading #
6) Received By Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00689 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Analyses Requested Lab Use Only Decommissioning Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State): Code &Type General Engineering Laboratories Code 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority: E] 30 D. E] 14 D. E 7 D.

Other: __

Sample Designation Date Time 1 Comment, Preservation Lab Sample ID 9522-0004-0391 11/28/06 1410 TS G BP X 9522-0004-0401 11/28/06 1412 TS G BP X 9522-0004-0411 11/28/06 1430 TS G BP X 9522-0004-0421 11/28/06 1432 TS G BP X 9522-0004-0431 11/28/06 1454 TS G BP X 9522-0004-0441 11/28/06 1456 TS G BP X 9522-0004-0451 11/29/06 0745 TS G BP X 9522-0004-0461 11/29/06 0746 TS G BP X 9522-0004-0471 11/29/06 0810 TS G BP X 9522-0004-0481 11/29/06 0812 TS G BP X 9522-0004-0491 11/29/06 1010 TS G BP X NOTES: P0 #J: 002332 MSR #I:o - #5C6(p LTP QA I Radwaste QA El Non QA Samples Shipped Via: Internal Container N Fed Ex Temp.: __ Deg. C E]ups El Hand Custody Sealed?

YE] NO]

1) Relinquished By Date/Time 2) 1ecvedBy Date/Time Custody Seal Intact?

___ ___ ___ __ ___(it. l ( 6 t  : El Other

3) Relinquished By Date/Time 4) Received By V Date/Time BillofLading_# _Y [ N ]

Bill of Lading #

5) Relinquished By Date/Time 6) Received By Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00691 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 _____________________ _______________________

Project Name: Haddam Neck Analyses Requested Lab Use Only Decommissioning Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Media Sample Container Code Type Size-Analytical Lab (Name, City, State): Code &Type General Engineering Laboratories Code 2040 Savage Road Charleston, SC 29407 ATT: Cheryl Jones (843-556-8171)

Priority: E] 30 D.E] 14 D. E 7 D.

Other: t

-_c .1 Sample Designation Date Time - - - Comment, Preservation Lab Sample ID 9522-0004-0501 11/29/06 1012 TS G BP X 9522-0004-0511 11/29/06 1019 TS G BP X Samples Shipped Via: Internal Container NOTES: P0 #: 002332 MSR #: O(- I6(4 [ LTP QA El Radwaste QA El Non QA [ Fed Ex Temp.: _ Deg. C El ups Dl Hand Custody Sealed?

YO NO]

1)Relinquished By Date/Time 2) Reo% By* ate/Time Custody Seal Intact?

3) Relinquished By Date/Time 4) Received By 4ate/Time BillofLading __ YO NE
5) Relinquished By Date/Time 6) Received By Date/Time

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Timc Received: . C / 0 1* /0 SDG#: tSk .'*oL,- tD3 AA..- . -

Work Order Number: J'fx --+ k,. q0 Shipping Container ID: Oicd 3, ne o e nu* l1I* -

1. Custody Seals on shipping container intact? Yes XNo []
2. Custody Seals dated and signed? Yes ] No
3. Chain-of-Custody record present? Yes L.No ]
4. Cooler temperature _ Co-4" -
5. Vermiculite/packing materials is: Wet [ Dry
6. Number of samples in shipping container:
7. Sample holding times exceeded? Yes H No
8. Samples have:

(jtape hazard labels custody seals __ appropriate sample labels

9. Samples are:

- in good condition __ .leaking broken have air bubbles

10. Were any anomalies identified in sample receipt'? Yes [N]No
11. Description of anomalies (include sample numbers): r :iO Sample CustodianrLaboratory: ______ __ _ _-_ Date: If' 3" 0 Telephoned to: On By_

Page 45 of 56 12

ENG4 SAMPLE RECEIPT & REVIEW FORM PC, PM use o0l6 Client: p¶ii A\ tj SGACCW Order:It 9c (o' SDate Received:% (OL ~ PM(A) Review (ensure non-M rcoafa tens are resolved prior 14 signing):

lReceived By:.-- -

Sample Receipt Criteria r Comments/Qualifners (Required for Non-Coufonmniii Items)

Shipping containers received intact Circle Applicable: seals broken damaged container leaking container odiet, (describe) and sealed? ,

Samples requiring cold Circle Coolant I ice bags blue ice dry ice none Nher describe) 2 preservation within (4 -f/-2 C)?

,Record preservation method. _ __ __ ___ __ __

Chain of custody documents, included with shipment?4 r

,sealed? ....

Sample containers intact and ircle Applicable: seals broken damaged contiiner leaking container -(describe)

Samples requiring chemical Sample lD's. containers affected and observed pH:

pre se rv atio n at prope r p H ? __....

VOA vials free of headspace sample ID's and containers affected:

(defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory)

Samples received within holding ids and tests affected:

S ime?

Sample ID's on COC match ID's Sample ID's and containers affected:

9 o n bottl e s ? .. .. __

Date & time on COC match date Sample ID's affected:

10 & time on bottles?__

Number of containers received sample ID's affected:

match number indicated on COC? V COC form is properly signed in 12 relinquished/received sections? _ _ _0 f__

_ _ _ _ _ _

Air Bill ,Tracking #'s, & q t z I P 7 &Ag - " V"q=A-A dditional Com ments c, "c(To'0 , %q %(D / 9 "/ a3 .l WW ;I-VRSO RAD Receiptfi

  • If > x2 area background is observed on samples identified a1"non-Suspected Hazard Information  : regulated/non-radioactive, contact the Radiation Safety group for further investigation.

A Rdological Classification? Maximum Counts Observed*:

B "CBRegulated?

Manager asorDOT Shipped ESH Hazardous Manager. U# Class Shipped:

Hazard Material? If yes, contact Waste Megulated as a Foreign Soil?JA PM (or PMA) mM review of Hazard classification:- inials (!i" Date: 1--

I 13 (

SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM I1I o (oC, - CDC (no2 Ac'o( 0 (-(Dr~

_______0 _ _ _ - - O (o (o05,o 6rl

~- oo 6,K

- oo~6,L 1.4

Data Review Qualifier Definitions 15

Data Review Qualifier Definitions Qualifier Explanation

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound
  • Result is less than value reported

> Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank B Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample d 5-day BOD-The 2:1 depletion requirement was not met for this sample E Organics-Concentration of the target analyte exceeds the instrument calibration range E Metals-%difference of sample and SD is >10%. Sample concentration must meet flagging criteria H Analytical holding time was exceeded h Preparation or preservation holding time was exceeded J Value is estimated N Metals-The Matrix spike sample recovery is not within specified control limits N Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound Z Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charlesion, SC 29417 , 2040 Savage Road (29407)

Phone (843) 556-8171 - Fa1.63) 766-1178 www.gel.com

RADIOLOGICAL ANAL YSIs 17

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 176890 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 592107 Prep Batch Number: 592100 Dry Soil Prep GL-RAD-A-021 Batch Number: 592097 Sample ID Client ID 176890005 9522-0004-004F 176890008 9522-0004-007F 1201238056 Method Blank (MB) 1201238057 176896007(9522-0001-014F) Sample Duplicate (DUP) 1201238058 176896007(9522-0001-014F) Matrix Spike (MS) 1201238059 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 I REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

3.8

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176896007 (9522-0001-014F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 19

Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-I I-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 592108 Prep Batch Number: 592100 Dry Soil Prep GL-RAD-A-021 Batch Number: 592097 Sample ID Client ID 176890005 9522-0004-004F 176890008 9522-0004-007F 1201238060 Method Blank (MB) 1201238061 176896007(9522-0001-014F) Sample Duplicate (DUP) 1201238062 176896007(9522-0001-014F) Matrix Spike (MS) 1201238063 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176896007 (9522-0001-014F).

QC Information All of the QC samples met the required acceptance limits.

20

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-I I-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 592109 Prep Batch Number: 592100 Dry Soil Prep GL-RAD-A-021 Batch Number: 592097 21

Sample ID Client ID 176890005 9522-0004-004F 176890008 9522-0004-007F 1201238064 Method Blank (MB) 1201238065 176896007(9522-0001-014F) Sample Duplicate (DUP) 1201238066 176896007(9522-0001-014F) Matrix Spike (MS) 1201238067 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176896007 (9522-0001-014F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 22

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 592142 Prep Batch Number: 592097 Sample ID Client ID 176890001 9522-0004-001F 176890002 9522-0004-001FS 176890003 9522-0004-002F 176890004 9522-0004-003F 176890005 9522-0004-004F 176890006 9522-0004-005F 176890007 9522-0004-006F 176890008 9522-0004-007F 176890009 9522-0004-008F 176890010 9522-0004-009F 176890011 9522-0004-OIOF 176890012 9522-0004-01 IF 176890013 9522-0004-012F 176890014 9522-0004-013F 176890015 9522-0004-014F 176890016 9522-0004-015F 1201238141 Method Blank (MB) 1201238142 176890002(9522-0004-OO1FS) Sample Duplicate (DUP) 1201238143 Laboratory Control Sample (LCS) 23

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 3 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176890002 (9522-0004-001FS).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The sample and the duplicate, 1201238142 (9522-0004-00lFS) and 176890002 (9522-0004-0OlFS),

did not meet the relative percent difference requirement for Ac-228 and TI-208, however they do meet the relative error ratio requirement with value of 2.44 for Ac-228 and 1.80 for T1-208.

24

Qualifier information Qualifier Reason Analyte Sample U' Data rejected due to high peak-width. Cesium- 137 176890004 Cobalt-60 176890016 UI Data rejected due to interference. Europium- 155 176890014 Manganese-54 176890012 176890016 UI Data rejected due to low abundance. Americium-241 176890012 Cesium-134 176890001 176890005 176890009 176890011 176890012 176890014 176890015 1201238142 Cobalt-60 176890011 Europium- 155 176890015 Manganese-54 176890011 Thallium-208 1201238141 Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 592146 Prep Batch Number: 592097 25

Sample ID Client ID 176890017 9522-0004-016F 176890018 9522-0004-0171 176890019 9522-0004-0181 176890020 9522-0004-0191 176890021 9522-0004-0201 176890022 9522-0004-0211 176890023 9522-0004-0221 176890024 9522-0004-0231 176890025 9522-0004-0241 176890026 9522-0004-0251 176890027 9522-0004-0261 176890028 9522-0004-0271 176890029 9522-0004-0281 176890030 9522-0004-0291 176890031 9522-0004-0301 176890032 9522-0004-0311 176890033 9522-0004-0321 176890034 9522-0004-0331 176890035 9522-0004-0341 176890036 9522-0004-0351 1201238149 Method Blank (MB) 1201238150 176890021(9522-0004-0201) Sample Duplicate (DUP) 1201238151 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC 26

The following sample was used for QC: 176890021 (9522-0004-0201).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The sample and the duplicate, 1201238150 (9522-0004-0201) and 176890021 (9522-0004-0201), did not meet the relative percent difference requirement for Bi-214, Ra-226 and T1-208, however they do meet the relative error ratio requirement with value of 2.44 for Bi-214 and Ra-226 and 1.8 for T1-208.

Qualifier information 27

Qualifier Reason Analyte Sample U' Data rejected due to interference. Europium- 155 176890025 176890030 176890033 Manganese-54 176890025 UI Data rejected due to low abundance. Americium-241 176890035 Cesium- 134 176890017 176890022 176890023 176890024 176890025 176890026 176890027 176890028 176890030 176890034 176890035 Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 592150 Prep Batch Number: 592098 28

Sample ID Client ID 176890037 9522-0004-0361 176890038 9522-0004-0371 176890039 9522-0004-0381 176890040 9522-0004-0391 176890041 9522-0004-0401 176890042 9522-0004-0411 176890043 9522-0004-0421 176890044 9522-0004-0431 176890045 9522-0004-0441 176890046 9522-0004-0451 176890047 9522-0004-0461 176890048 9522-0004-0471 176890049 9522-0004-0481 176890050 9522-0004-0491 176890051 9522-0004-0501 176890052 9522-0004-0511 1201238152 Method Blank (MB) 1201238153 176890037(9522-0004-0361) Sample Duplicate (DUP) 1201238154 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (0C0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176890037 (9522-0004-0361).

QC Information All of the QC samples met the required acceptance limits.

29

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 176890043 (9522-0004-0421) was recounted due to high MDA.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Oualifier information 30

Qualifier Reason Analyte Sample UI Data rejected due to high peak-width. Manganese-54 176890049 UI Data rejected due to interference. Cesium- 134 176890042 176890051 Europium-155 176890045 176890048 176890049 176890050 176890051 Manganese-54 176890043 UI Data rejected due to low abundance. Cesium- 134 176890038 176890043 176890044 176890045 176890046 176890047 176890048 176890049 176890050 176890052 1201238153 Potassium-40 1201238152 Method/Analysis Information 31

Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 592186 Prep Batch Number: 592100 Dry Soil Prep GL-RAD-A-021 Batch Number: 592097 Sample ID Client ID 176890005 9522-0004-004F 176890008 9522-0004-007F 1201238231 Method Blank (MB) 1201238232 176896007(9522-0001-014F) Sample Duplicate (DUP) 1201238233 176896007(9522-0001-014F) Matrix Spike (MS) 1201238234 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176896007 (9522-0001-014F).

QC Information Refer to Non-Conformance Report.

32

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following NCR was generated for this SDG:

NCR 390300 was generated due to Container scanning event for custody missed and Failed RPD for DUP. 1. Sample 176896007 and 1201238232 did not meet the relative percent difference due to the matrix of the sample. Large amounts of the sample was used to achieve the detection limit. 2. The analyst did not scan the samples 176890005, 176890008, 176896007, and 176896010 into the batch prior to analysis, however the samples did remain in their custody at all times. The error has been corrected and the analyst has been instructed on the proper scanning procedures. 1. Client was contacted and granted relief to report results. 2. Reporting results.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 592312 33

Sample ID Client ID 176890005 9522-0004-004F 176890008 9522-0004-007F 1201238554 Method Blank (MB) 1201238555 176896007(9522-0001-014F) Sample Duplicate (DUP) 1201238556 176896007(9522-0001-014F) Matrix Spike (MS) 1201238557 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176896007 (9522-0001-014F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 34

referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The blank result for 1201238554 (MB) is greater than the MDA but less than the detection limit.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 592304 Prep Batch Number: 592100 Dry Soil Prep GL-RAD-A-021 Batch Number: 592097 Sample ID Client ID 176890005 9522-0004-004F 176890008 9522-0004-007F 1201238526 Method Blank (MB) 1201238527 176518004(9504-0000-004F) Sample Duplicate (DUP) 1201238528 176518004(9504-0000-004F) Matrix Spike (MS) 1201238529 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry 35

All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176518004 (9504-0000-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 176890005 (9522-0004-004F) and 176890008 (9522-0004-007F) were reprepped due to high blank activity.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 36

Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 592310 Prep Batch Number: 592100 Dry Soil Prep GL-RAD-A-021 Batch Number: 592097 Sample ID Client ID 176890005 9522-0004-004F 176890008 9522-0004-007F 1201238546 Method Blank (MB) 1201238547 176896007(9522-0001-014F) Sample Duplicate (DUP) 1201238548 176896007(9522-0001-014F) Matrix Spike (MS) 1201238549 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176896007 (9522-0001-014F).

QC Information All of the QC samples met the required acceptance limits.

37

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: LSC, Tritium Dist, Solid - 3 pCi/g Analytical Method: EPA 906.0 Modified Analytical Batch Number: 593064 Sample ID Client ID 176890005 9522-0004-004F 176890008 9522-0004-007F 1201240325 Method Blank (MB) 1201240326 176890008(9522-0004-007F) Sample Duplicate (DUP) 1201240327 176890008(9522-0004-007F) Matrix Spike (MS) 1201240328 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.

38

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176890008 (9522-0004-007F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 176890005 (9522-0004-004F) and 176890008 (9522-0004-007F) were reprepped due to low/high recovery.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 39

Product: Liquid Scint C14, Solid All,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 592313 Sample ID Client ID 176890005 9522-0004-004F 176890008 9522-0004-007F 1201238558 Method Blank (MB) 1201238559 176896007(9522-0001-014F) Sample Duplicate (DUP) 1201238560 176896007(9522-0001-014F) Matrix Spike (MS) 1201238561 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 176896007 (9522-0001-014F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

40

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

1Zf2

7. r Reviewer/Date:

41

General Engineering Laboratories NCR Report No.: 390300 Form GEL-NCR Revision No.:

Rev. 06/05 COMPANY - WIDE NONCONFORMANCE REPORT Mo.Day Yr. Division: Quality Criteria: Type:

07-DEC-06 Radiochemistry Specifications Process Instrument Type: Test I Method: Matrix Type: Client Code:

GFPC EPA 905.0 Modified Solid YANK Batch ID: Sample Numbers:

592186 See Below Potentially affected work order(s)(SDG): 176890(MSR#06-1506),176896(MSR#06-1505)

Application Issues:

Container scanning event for custody missed Failed RPD for DUP Specification and Requirements NRG Disposition:

Nonconformance

Description:

1. Sample 176896007 and 1201238232 did not meet the relative percent 1. Client was contacted and granted relief to report results.

difference due to the matrix of the sample. Large amounts of the sample was used to achieve the detection limit.

2. The analyst did not scan the samples 176890005, 176890008, 2. Reporting results.

176896007, and 176896010 into the batch prior to analysis, however the samples did remain in their custody at all times. The error has been corrected and the analyst has been instructed on the proper scanning procedures.

Originator's Name: Data Validator/Group Leader:

Melanie Aycock 07-DEC-06 Heather Anderson 07-DEC-06 Quality Review:

Director:

Page 1 42

SAMPLE DATA

SUMMARY

43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-1506 GEL Work Order: 176890 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-OOIF Project: YANKO 1204 Sample ID: 176890001 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 6.28%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.505 +/-0.141 0.0508 +/-0.141 0.110 pCi/g MJHI 12/02/06 0941 592142 Americium-241 U 0.101 +/-0.108 0.073 +/-0.108 0.150 pCi/g Bismuth-212 0.330 +/-0.218 0.104 +/-0.218 0.224 pCi/g Bismuth-214 0.462 +/-0.0864 0.0295 +/-0.0864 0.0624 pCi/g Cesium-134 UI 0.00 +/-0.0243 0.0187 +/-0.0243 0.0398 pCi/g Cesium-137 0.0479 +/-0.0243 0.0165 +/-0.0243 0.0349 pCi/g Cobalt-60 U 0.0184 +/-0.0207 0.019 +/-0.0207 0.0412 pCi/g Europium-152 U -0.0161 +/-0.0504 0.0436 +/-0.0504 0.0912 pCi/g Europium-154 U 0.0615 +/-0.0797 0.0526 +/-0.0797 0.114 pCi/g Europium-155 U 0.0156 +/-0.0517 0.0496 +/-0.0517 0.102 pCi/g Lead-212 0.527 +/-0.0483 0.0249 +/-0.0483 0.0516 pCi/g Lead-214 0.554 +/-0.0723 0.0306 +/-0.0723 0.0641 pCi/g Manganese-54 U 0.00984 +/-0.0178 0.0143 +/-0.0178 0.0307 pCi/g Niobium-94 U 0.00427 +/-0.0154 0.0139 +/-0.0154 0.0295 pCi/g Potassium-40 10.4 +/-0.755 0.121 +/-0.755 0.273 pCi/g Radium-226 0.462 +/-0.0864 0.0295 +/-0.0864 0.0624 pCi/g Silver-108m U 0.00627 +/-0.0184 0.0139 +/-0.0184 0.0293 pCi/g Thallium-208 0.164 +/-0.0352 0.016 +/-0.0352 0.0339 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-OOIF Project: YANK01204 Sample ID: 176890001 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UL Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

46

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-OO1FS Project: YANK01204 Sample ID: 176890002 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 6.35%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.499 +/-0.133 0.0506 +/-0.133 0.101 pCi/g MJH1 12/02/06 0945 592142 Americium-241 U 0.0286 +/-0.0593 0.0503 +/-0.0593 0.101 pCi/g Bismuth-212 0.400 +/-0.177 0.0961 +/-0.177 0.192 pCi/g Bismuth-214 0.425 +/-0.0754 0.0273 +/-0.0754 0.0546 pCi/g Cesium-134 U 0.0213 +/-0.0198 0.0175 +/-0.0198 0.0349 pCi/g Cesium-137 0.0722 +/-0.0297 0.0146 +/-0.0297 0.0291 pCi/g Cobalt-60 U 0.0304 +/-0.0183 0.0171 +/-0.0183 0.0341 pCi/g Europium-152 U 0.00662 +/-0.0743 0.0396 +/-0.0743 0.0791 pCi/g Europium-154 U 0.00889 +/-0.098 0.0455 +/-0.098 0.091 pCi/g Europium-155 U 0.0169 +/-0.0482 0.0422 +/-0.0482 0.0843 pCi/g Lead-212 0.527 +/-0.0622 0.022 +/-0.0622 0.044 pCi/g Lead-214 0.556 +/-0.0808 0.0279 +/-0.0808 0.0558 pCi/g Manganese-54 U 0.00229 +/-0.0177 0.0152 +/-0.0177 0.0305 pCi/g Niobium-94 U -0.0108 +/-0.0173 0.0124 +/-0.0173 0.0248 pCi/g Potassium-40 11.4 +/-0.994 0.127 +/-0.994 0.254 pCi/g Radium-226 0.425 +/-0.0754 0.0273 +/-0.0754 0.0546 pCi/g Silver-108m U 0.0032 +/-0.0141 0.0128 +/-0.0141 0.0255 pCi/g Thallium-208 0.144 +/-0.0319 0.0134 +/-0.0319 0.0268 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-001FS Project: YANK01204 Sample ID: 176890002 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-002F Project: YANK01204 Sample ID: 176890003 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 3.79%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.410 +/-0.141 0.0489 +/-0.141 0.106 pCi/g MJH1 12/02/06 0943 592142 Americium-241 U -0.0034 +/-0.0201 0.0184 +/-0.0201 0.038 pCi/g Bismuth-212 0.275 +/-0.146 0.105 +/-0.146 0.227 pCi/g Bismuth-214 0.357 +/-0.0694 0.0239 +/-0.0694 0.0513 pCi/g Cesium-134 U 0.0197 +/-0.0236 0.016 +/-0.0236 0.0343 pCi/g Cesium-137 0.0748 +/-0.0253 0.0153 +/-0.0253 0.0327 pCi/g Cobalt-60 U 0.016 +/-0.0208 0.014 +/-0.0208 0.0311 pCi/g Europium-152 U -0.0117 +/-0.0378 0.0322 +/-0.0378 0.068 pCi/g Europium-154 U -0.0124 +/-0.0492 0.0406 +/-0.0492 0.0897 pCi/g Europium-155 U 0.0482 +/-0.044 0.0326 +/-0.044 0.0675 pCi/g Lead-212 0.480 +/-0.0418 0.0194 +/-0.0418 0.0404 pCi/g Lead-214 0.502 +/-0.0689 0.024 +/-0.0689 0.0507 pCi/g Manganese-54 U 0.00522 +/-0.0164 0.0144 +/-0.0164 0.0309 pCi/g Niobium-94 U -0.00705 +/-0.0173 0.0124 +/-0.0173 0.0267 pCi/g Potassium-40 8.93 +/-0.761 0.143 +/-0.761 0.318 pCi/g Radium-226 0.357 +/-0.0694 0.0239 +/-0.0694 0.0513 pCi/g Silver-108m U 0.00671 +/-0.0129 0.0122 +/-0.0129 0.0259 pCi/g Thallium-208 0.142 +/-0.0379 0.0123 +/-0.0379 0.0264 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 49

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-002F Project: YANK01204 Sample ID: 176890003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

50

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-003F Proiect: YANK0l1204 Sample ID: 176890004 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 3.6%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.454 +/-0.182 0.0601 +/-0.182 0.132 pCi/g MJHI 12/02/06 0943 592142 Americium-241 U -0.0196 +/-0.0276 0.0248 +/-0.0276 0.0514 pCi/g Bismuth-212 0.451 +/-0.279 0.142 +/-0.279 0.307 pCi/g Bismuth-214 0.427 +/-0.103 0.0325 +/-0.103 0.0699 pCi/g Cesium-134 U 0.0223 +/-0.0273 0.0232 +/-0.0273 0.0499 pCi/g Cesium-137 UI 0.00 +/-0.049 0.0183 +/-0.049 0.0395 pCi/g Cobalt-60 U -0.00362 +/-0.0255 0.0207 +/-0.0255 0.0458 pCi/g Europium-152 U -0.0436 +/-0.0441 0.0361 +/-0.0441 0.0774 pCi/g Europium-154 U 0.0274 +/-0.0663 0.0583 +/-0.0663 0.129 pCi/g Europium-155 U 0.0669 +/-0.0506 0.034 +/-0.0506 0.0712 pCi/g Lead-212 0.467 +/-0.0503 0.0215 +/-0.0503 0.0452 pCi/g Lead-214 0.487 +/-0.0651 0.029 +/-0.0651 0.0617 pCi/g Manganese-54 U -0.00936 +/-0.0218 0.0182 +/-0.0218 0.0396 pCi/g Niobium-94 U -0.00696 +/-0.0192 0.0166 +/-0.0192 0.0357 pCi/g Potassium-40 11.7 +/-0.884 0.141 +/-0.884 0.328 pCi/g Radium-226 0.427 +/-0.103 0.0325 +/-0.103 0.0699 pCi/g Silver-108m U -0.019 +/-0.0171 0.0134 +/-0.0171 0.0289 pCi/g Thallium-208 0.178 +/-0.051 0.0172 +/-0.051 0.0371 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-003F Project: YANK0 1204 Sample ID: 176890004 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

52

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-004F Proiect: YANK01204 Sample ID: 176890005 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 6.55%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0773 +/-0.134 0.0766 +/-0.134 0.241 pCi/g MXA 12/03/06 0901 592107 M

Curium-242 U 0.0338 +/-0.0663 0.00 +/-0.0665 0.0917 pCi/g Curium-243/244 U -0.0349 +/-0.126 0.119 +/-0.126 0.326 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0943 +/-0.166 0.166 +/-0.167 0.420 pCi/g MXA 12/03/06 0901 592108 I

Plutonium-239/240 U -0.0439 +/-0.106 0.108 +/-0.106 0.304 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 0.614 +/-6.74 5.63 +/-6.74 11.9 pCi/g MXA 12/05/06 1849 592109 I

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.560 +/-0.0978 0.0334 +/-0.0978 0.0724 pCi/g MJH1 12/02/06 0944 592142 Americium-241 U 0.0637 +/-0.0861 0.0785 +/-0.0861 0.162 pCi/g Bismuth-212 0.489 +/-0.189 0.0805 +/-0.189 0.172 pCi/g Bismuth-214 0.389 +/-0.0683 0.022 +/-0.0683 0.0465 pCi/g Cesium-134 UI 0.00 +/-0.019 0.0153 +/-0.019 0.0323 pCi/g Cesium-] 37 0.043 +/-0.0279 0.0126 +/-0.0279 0.0267 pCi/g Cobalt-60 U 0.0157 +/-0.0149 0.0141 +/-0.0149 0.0304 pCi/g Europium-152 U -0.0153 +/-0.0351 0.0311 +/-0.0351 0.0652 pCi/g Europium-154 U -0.00144 +/-0.045 0.039 +/-0.045 0.0838 pCi/g Europium-155 U 0.0235 h/-0.0433 0.0414 +/-0.0433 0.0857 pCi/g Lead-212 0.493 /-0.0443 0.0214 +/-0.0443 0.0444 pCi/g Lead-214 0.504 +/-0.070 0.0231 +/-0.070 0.0485 pCi/g Manganese-54 U 0.0137 /-0.0142 0.012 +/-0.0142 0.0255 pCi/g Niobium-94 U 0.00402 4-0.0134 0.0122 +/-0.0134 0.0256 pCi/g Potassium-40 11.3 +/-0.674 0.117 +/-0.674 0.255 pCi/g Radium-226 0.389 4-0.0683 0.022 +/-0.0683 0.0465 pCi/g Silver-108m U 0.0115 4-0.0123 0.0115 +/-0.0123 0.0241 pCi/g Thallium-208 0.155 0.0284 0.0118 +/-0.0284 0.025 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 1.26 +/-0.114 0.0227 +/-0.118 0.053 pCi/g KSDI 12/07/06 1151 592186 Rad Liquid Scintillation Analysis 53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-004F Project: YANK01204 Sample ID: 176890005 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid - 3 pCi/g Tritium U -0.152 +/-1.28 1.08 +/-1.28 2.21 pCi/g DFAl 12/05/06 2151 593064 Liquid Scint C14, Solid All, FSS Carbon-14 U 0.0539 +/-0.0908 0.0751 +/-0.0908 0.154 pCi/g AXD2 12/01/06 1731 592313 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -3.89 +/-35.1 27.0 +/-35.1 56.8 pCi/g MXPI 12/02/06 1816 592304 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -5.42 +/-11.5 9.88 +/-11.5 20.8 pCi/g MXP1 12/04/06 2015 592310 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.087 +/-0.159 0.131 +/-0.159 0.270 pCi/g KXR1 12/06/06 1650 592312 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified 3 DOE EML HASL-300, Pu- I -RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA 906.0 Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-I, Modified 10 DOE RESL Ni-1, Modified 11 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 91 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 97 (15%-125%)

Plutonium-241 Liquid Scint Pu241, Solid-ALL Fý 84 (25%-125%)

Strontium-90 GFPC, Sr90, solid-ALL FSS 44 (25%-125%)

54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-004F Project: YANKO01204 Sample ID: 176890005 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch, 1 Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 44 (25%-125%)

Iron-55 Liquid Scint Fe55, Solid-ALL FS 68 (15%-125%)

Nickel-63 Liquid Scint Ni63, Solid-ALL FS 67 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 67 (25%-125%)

Technetium-99 Liquid Scint Tc99, Solid-ALL FS 76 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 76 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-005F Project: YANK01204 Sample ID: 176890006 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 5.44%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.432 +/-0.131 0.0451 +/-0.131 0.0902 pCi/g MJH1 12/02/06 0947 592142 Americium-241 U -0.00665 +/-0.0596 0.0493 +/-0.0596 0.0985 pCi/g Bismuth-212 0.413 +/-0.244 0.113 +/-0.244 0.226 pCi/g Bismuth-214 0.270 +/-0.0712 0.0288 +/-0.0712 0.0575 pCi/g Cesium-134 U 0.017 +/-0.0173 0.0161 +/-0.0173 0.0321 pCi/g Cesium-137 U -0.0031 +/-0.0161 0.0137 +/-0.0161 0.0273 pCi/g Cobalt-60 U 0.0051 +/-0.0147 0.0131 +/-0.0147 0.0262 pCi/g Europium-152 U 0.0501 +/-0.0528 0.0382 +/-0.0528 0.0764 pCi/g Europium-154 U 0.00935 +/-0.0579 0.0436 +/-0.0579 0.0871 pCi/g Europium-155 U 0.0332 +/-0.0562 0.0381 +/-0.0562 0.0762 pCi/g Lead-212 0.308 +/-0.0472 0.0205 +/-0.0472 0.0409 pCi/g Lead-214 0.370 +/-0.0604 0.0241 +/-0.0604 0.0482 pCi/g Manganese-54 U 0.00292 +/-0.0142 0.0128 +/-0.0142 0.0256 pCi/g Niobium-94 U -0.00507 +/-0.0151 0.0126 +/-0.0151 0.0251 pCi/g Potassium-40 6.41 +/-0.724 0.126 +/-0.724 0.251 pCi/g Radium-226 0.270 +/-0.0712 0.0288 +/-0.0712 0.0575 pCi/g Silver-108m U -0.0123 +/-0.0143 0.0119 +/-0.0143 0.0239 pCi/g Thallium-208 0.104 +/-0.0301 0.0127 +/-0.0301 0.0254 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 56

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-005F Project: YANK01204 Sample ID: 176890006 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Arnalysis Certificate ofAnalvsis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-006F Project: YANK01204 Sample ID: 176890007 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 4.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.552 +/-0.173 0.0824 +/-0.173 0.165 pCi/g MJHI 12/02/06 0948 592142 Americium-241 U 0.0042 +/-0.0407 0.0286 +/-0.0407 0.0571 pCi/g Bismuth-212 0.684 +/-0.351 0.143 +/-0.351 0.286 pCi/g Bismuth-214 0.653 +/-0.108 0.038 +/-0.108 0.0759 pCi/g Cesium-134 U 0.030 +/-0.0395 0.0251 +/-0.0395 0.0502 pCi/g Cesium-137 0.0948 +/-0.0447 0.0217 +/-0.0447 0.0433 pCi/g Cobalt-60 U -0.00583 +/-0.0302 0.0249 +/-0.0302 0.0497 pCi/g Europium-152 U -0.0473 +/-0.0695 0.0479 +/-0.0695 0.0958 pCi/g Europium-154 U 0,0236 +/-0.084 0.0733 +/-0.084 0.147 pCi/g Europium-155 U 0.0666 +/-0.070 0.0427 +/-0.070 0.0853 pCi/g Lead-212 0.546 +/-0.0718 0.0271 +/-0.0718 0.0543 pCi/g Lead-214 0.691 +/-0.102 0.0351 +/-0.102 0.0702 pCi/g Manganese-54 U 0.00605 +/-0.0241 0.0216 +/-0.0241 0.0432 pCi/g Niobium-94 U -0.00578 +/-0.0204 0.0178 +/-0.0204 0.0355 pCi/g Potassium-40 8.43 +/-0.898 0.191 +/-0.898 0.381 pCi/g Radium-226 0.653 +/-0.108 0.038 +/-0.108 0.0759 pCi/g Silver-108m U 0.0111 +/-0.0188 0.0173 +/-0.0188 0.0346 pCi/g Thallium-208 0.201 +/-0.0487 0.0194 +/-0.0487 0.0388 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-006F Project: YANK01204 Sample ID: 176890007 Client ID:

Vol. Recv.: YANKOO Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

59

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-007F Proiect: YANK01204 Sample ID: 176890008 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.48%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.0139 +/-0.0228 0.039 +/-0.0229 0.161 pCi/g MXA 12/03/06 0901 592107 I

Curium-242 U -0.00774 +/-0.0152 0.0289 +/-0.0152 0.145 pCi/g Curium-243/244 U 0.0258 +/-0.113 0.0828 +/-0.113 0.249 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.180 +/-0.216 0.125 +/-0.217 0.346 pCi/g MXA 12/03/06 0901 592108 M

Plutonium-239/240 U 0.0797 +/-0.122 0.0543 +/-0.122 0.203 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 5.85 +/-6.92 5.53 +/-6.95 11.7 pCi/g MXA 12/05/06 1905 592109 I

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.16 +/-0.214 0.0586 +/-0.214 0.126 pCi/g MJH1 12/02/06 1017 592142 Americium-241 U -0.0487 +/-0.0744 0.0674 +/-0.0744 0.138 pCi/g Bismuth-212 0.596 +/-0.271 0.138 +/-0.271 0.292 pCi/g Bismuth-214 0.733 +/-0.117 0.0314 +/-0.117 0.0664 pCi/g Cesium-134 U 0.0472 +/-0.0306 0.0233 +/-0.0306 0.049 pCi/g Cesium-137 U 0.0146 +/-0.0245 0.0192 +/-0.0245 0.0405 pCi/g Cobalt-60 U 0.0189 +/-0.0239 0.0196 +/-0.0239 0.0425 pCi/g Europium-152 U -0.0273 +/-0.0638 0.0482 +/-0.0638 0.100 pCi/g Europium-154 U -0.0372 +/-0.069 0.0563 +/-0.069 0.121 pCi/g Europium-155 U 0.043 +/-0.0596 0.0549 +/-0.0596 0.113 pCi/g Lead-212 0.957 +/-0.0966 0.0291 +/-0.0966 0.060 pCi/g Lead-214 0.876 +/-0.110 0.0371 +/-0.110 0.0771 pCi/g Manganese-54 U 0.010 +/-0.0202 0.0178 +/-0.0202 0.0377 pCi/g Niobium-94 U -0.00714 +/-0.0184 0.0153 +/-0.0184 0.0324 pCi/g Potassium-40 17.2 +/-1.37 0.137 +/-1.37 0.305 pCi/g Radium-226 0.733 +/-0.117 0.0314 +/-0.117 0.0664 pCi/g Silver-108m U -0.00733 +/-0.0179 0.0154 +/-0.0179 0.0324 pCi/g Thallium-208 0.318 +1-0.0501 0.0173 +/-0.0501 0.0364 pCi/g Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 0.190 +/-0.0324 0.0118 +/-0.0326 0.0271 pCi/g KSDI 12/07/06 1217 592186 Rad Liquid Scintillation Analysis 60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-007F Project: YANK01204 Sample ID: 176890008 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid - 3 pCi/g Tritium U -1.0 +/-1.29 1.11 +/-1.29 2.27 pCi/g DFAI 12/05/06 2358 593064 Liquid Scint C14, Solid All, FSS Carbon-14 U -0.0107 +/-0.0896 0.0754 +/-0.0896 0.154 pCi/g AXD2 12/01/06 1834 592313 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -4.71 +/-34.0 26.0 +/-34.0 54.6 pCi/g MXPI 12/02/06 1833 592304 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -5.05 +/-11.3 9.74 +/-11.3 20.5 pCi/g MXPI 12/04/06 2031 592310 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0801 +/-0.161 0.133 +/-0.161 0.274 pCi/g KXR1 12/06/06 1722 592312 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA 906.0 Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-1, Modified 10 DOE RESL Ni-i, Modified II DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 85 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 98 (15%-125%)

Plutonium-241 Liquid Scint Pu241, Solid-ALL F5 86 (25%-125%)

Strontium-90 GFPC, Sr90, solid-ALL FSS 79 (25%-125%)

61

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-007F Project: YANK01204 Sample ID: 176890008 Client ID: YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1r Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 79 (25%-125%)

Iron-55 Liquid Scint Fe55, Solid-ALL FS 73 (15%-125%)

Nickel-63 Liquid Scint Ni63, Solid-ALL FS 67 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 67 (25%-125%)

Technetium-99 Liquid Scint Tc99, Solid-ALL FS 76 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 76 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-008F Project: YANK01204 Sample ID: 176890009 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 6.58%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.456 +/-0.0648 0.0271 +/-0.0648 0.0572 pCi/g MJHI 12/02/06 1324 592142 Americium-241 U -0.00547 +/-0.048 0.0407 +/-0.048 0.0833 pCi/g Bismuth-212 0.359 +/-0.123 0.064 +/-0.123 0.134 pCi/g Bismuth-214 0.344 +/-0.0405 0.0154 +/-0.0405 0.0321 pCi/g Cesium-134 UI 0.00 +/-0.0138 0.0109 +/-0.0138 0.0227 pCi/g Cesium-137 0.0805 +/-0.017 0.00861 +/-0.017 0.018 pCi/g Cobalt-60 U 0.0157 +/-0.012 0.0111 +/-0.012 0.0234 pCi/g Europium-152 U -0.0035 +/-0.0246 0.0215 +/-0.0246 0.0444 pCi/g Europium-154 U 0.0191 +/-0.0315 0.0283 +/-0.0315 0.0597 pCi/g Europium-155 U 0.034 +/-0.0348 0.0254 +/-0.0348 0.0519 pCi/g Lead-212 0.405 +/-0.0318 0.0181 +/-0.0318 0.0369 pCi/g Lead-214 0.458 +/-0.0446 0.015 +/-0.0446 0.031 pCi/g Manganese-54 U 0.00553 +/-0.0108 0.0084 +/-0.0108 0.0176 pCi/g Niobium-94 U 0.00392 +/-0.00933 0.00832 +/-0.00933 0.0173 pCi/g Potassium-40 10.0 +/-0.443 0.0701 +/-0.443 0.152 pCi/g Radium-226 0.344 +/-0.0405 0.0154 +/-0.0405 0.0321 pCi/g Silver-108m U 0.00334 +/-0.00773 0.00725 +/-0.00773 0.0151 pCi/g Thallium-208 0.164 +/-0.023 0.00746 +/-0.023 0.0156 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis

. o . f. . n----i

...

. .. . ... .

Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-008F Project: YANKO 1204 Sample ID: 176890009 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

64

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-009F Proiect: YANK01204 Sample ID: 176890010 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.493 +/-0.133 0.0485 +/-0.133 0.101 pCi/g MJHI 12/02/06 1325 592142 Americium-241 U -0.0137 +/-0.0198 0.0171 +/-0.0198 0.0348 pCi/g Bismuth-212 0.518 +/-0.267 0.107 +/-0.267 0.222 pCi/g Bismuth-214 0.402 +/-0.0756 0.0246 +/-0.0756 0.0509 pCi/g Cesium-134 U 0.0238 +/-0.0218 0.017 +/-0.0218 0.0352 pCi/g Cesium-137 0.0556 +/-0.031 0.0144 +/-0.031 0.0299 pCi/g Cobalt-60 U -0.00376 +/-0.018 0.0148 +/-0.018 0.0313 pCi/g Europium-152 U 0.0231 +/-0.0394 0.034 +/-0.0394 0.0699 pCi/g Europium-154 U -0.00189 +1-0.051 0.0427 +/-0.051 0.0896 pCi/g Europium-155 U 0.0163 +/-0.0337 0.0288 +/-0.0337 0.0588 pCi/g Lead-212 0.366 +/-0.0452 0.0231 +/-0.0452 0.047 pCi/g Lead-214 0.451 +/-0.0566 0.0231 +/-0.0566 0.0475 pCi/g Manganese-54 U 0.0119 +/-0.0164 0.0142 +/-0.0164 0.0294 pCi/g Niobium-94 U 0.00231 +/-0.0151 0.0129 +/-0.0151 0.0266 pCi/g Potassium-40 10.5 +/-0.631 0.123 +/-0.631 0.262 pCi/g Radium-226 0.402 +/-0.0756 0.0246 +/-0.0756 0.0509 pCi/g Silver-108m U 0.00156 +/-0.0132 0.0118 +/-0.0132 0.0243 pCi/g Thallium-208 0.166 +/-0.0354 0.0128 +/-0.0354 0.0265 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 65

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-009F Project: YANKO 1204 Sample ID: 176890010 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

66

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-OIOF Project: YANK01204 Sample ID: 176890011 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 5.53%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.704 +/-0.0763 0.0223 +/-0.0763 0.0464 pCi/g MJHI 12/02/06 1350 592142 Americium-241 U -0.00025 +/-0.0531 0.0442 +/-0.0531 0.0901 pCi/g Bismuth-212 0.477 +/-0.104 0.0457 +/-0.104 0.095 pCi/g Bismuth-214 0.475 +/-0.0385 0.0136 +/-0.0385 0.0279 pCi/g Cesium-134 UI 0.00 +/-0.0149 0.00915 +/-0.0149 0.0188 pCi/g Cesium-137 0.075 +/-0.0139 0.00753 +/-0.0139 0.0155 pCi/g Cobalt-60 UI 0.00 +/-0.018 0.00821 +/-0.018 0.0171 pCi/g Europium-152 U 0.00487 +/-0.0198 0.0184 +/-0.0198 0.0378 pCi/g Europium-154 U -0.0208 +/-0.0239 0.020 +/-0.0239 0.0418 pCi/g Europium-155 U 0.0324 +/-0.0252 0.0249 +/-0.0252 0.0508 pCi/g Lead-212 0.711 +/-0.0277 0.011 +/-0.0277 0.0224 pCi/g Lead-214 0.512 +/-0.0358 0.0126 +/-0.0358 0.0259 pCi/g Manganese-54 UI 0.00 +/-0.00863 0.00736 +/-0.00863 0.0152 pCi/g Niobium-94 U 0.00158 +/-0.00697 0.00632 +/-0.00697 0.0131 pCi/g Potassium-40 9.50 +/-0.348 0.0554 +/-0.348 0.118 pCi/g Radium-226 0.475 +/-0.0385 0.0136 +/-0.0385 0.0279 pCi/g Silver-108m U 0.00399 +/-0.00686 0.00629 +/-0.00686 0.013 pCi/g Thallium-208 0.216 +/-0.0185 0.0066 +/-0.0185 0.0136 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 67

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-OIOF Project: YANK01204 Sample ID: 176890011 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

68

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-01F Project: YANK0 1204 Sample ID: 176890012 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 8.26%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 2.07 +/-0.283 0.0669 +/-0.283 0.134 pCi/g MJHI 12/02/06 1328 592142 Americium-241 UI 0.00 +/-0.0367 0.0286 +/-0.0367 0.0571 pCi/g Bismuth-212 1.46 +/-0.335 0.149 +/-0.335 0.298 pCi/g Bismuth-214 1.86 +/-0.211 0.0327 +/-0.211 0.0654 pCi/g Cesium-134 UI 0.00 +/-0.0373 0.0261 +/-0.0373 0.0521 pCi/g Cesium-137 U 0.0182 +/-0.0247 0.0196 +/-0.0247 0.0392 pCi/g Cobalt-60 U 0.0362 +/-0.0275 0.0219 +/-0.0275 0.0438 pCi/g Europium-152 U -0.0448 +/-0.0629 0.0446 +/-0.0629 0.0891 pCi/g Europium-154 U -0.0506 +/-0.0804 0.0657 +/-0.0804 0.131 pCi/g Europium-155 U 0.0806 +/-0.0637 0.0442 +/-0.0637 0.0884 pCi/g Lead-212 2.01 +/-0.181 0.0253 +/-0.181 0.0505 pCi/g Lead-214 1.91 +/-0.185 0.0324 +/-0.185 0.0648 pCi/g Manganese-54 UI 0.00 +/-0.0246 0.0181 +/-0.0246 0.0363 pCi/g Niobium-94 U -0.00434 +/-0.0204 0.018 +/-0.0204 0.0359 pCi/g Potassium-40 23.6 +/-1.11 0.160 +/-1.11 0.320 pCi/g Radium-226 1.86 +/-0.211 0.0327 +/-0.211 0.0654 pCi/g Silver-108m U -0.0196 +/-0.0183 0.0155 +/-0.0183 0.031 pCi/g Thallium-208 0.681 +/-0.0772 0.0182 +/-0.0772 0.0363 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 69

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-01 IF Proiect: YANK01204 Sample ID: 176890012 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

70

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 lnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-012F Proiect: YANK01204 Sample ID: 176890013 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Mnkiirpwe AR 1)0/

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1l Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.434 +/-0.133 0.0492 +/-0.133 0.108 pCi/g MJHI 12/04/06 0655 592142 Americium-241 U 0.0362 +/-0.135 0.071 +/-0.135 0.148 pCi/g Bismuth-212 U 0.188 +/-0.212 0.0947 +/-0.212 0.208 pCi/g Bismuth-214 0.337 +/-0.0695 0.0269 +/-0.0695 0.0579 pCi/g Cesium-134 U 0.0161 +/-0.0204 0.0187 +/-0.0204 0.0402 pCi/g Cesium-137 0.0419 +/-0.0209 0.0135 +/-0.0209 0.0294 pCi/g Cobalt-60 U 0.0204 +/-0.0157 0.0182 +/-0.0157 0.0402 pCi/g Europium-152 U 0.0107 +/-0.0423 0.0371 +/-0.0423 0.0788 pCi/g Europium-154 U 0.00812 +/-0.0518 0.0451 +/-0.0518 0.100 pCi/g Europium-155 U 0.000967 +/-0.0427 0.0406 +/-0.0427 0.0848 pCi/g Lead-212 0.420 +/-0.0477 0.0214 +/-0.0477 0.0449 pCi/g Lead-214 0.333 +/-0.0605 0.0255 +/-0.0605 0.0543 pCi/g Manganese-54 U 0.00119 +/-0.0182 0.0155 +/-0.0182 0.0336 pCi/g Niobium-94 U 0.00262 +/-0.0137 0.0121 +/-0.0137 0.0263 pCi/g Potassium-40 6.57 +/-0.649 0.100 +/-0.649 0.238 pCi/g Radium-226 0.337 +/-0.0695 0.0269 +/-0.0695 0.0579 pCi/g Silver-108m U -0.00144 +/-0.0129 0.0116 +/-0.0129 0.025 pCi/g Thallium-208 0.158 +/-0.0325 0.0145 +/-0.0325 0.0311 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 71

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-012F Project: YANK01204 Sample ID: 176890013 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

72

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-013F Project: YANK01204 Sample ID: 176890014 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 78.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch IN Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.908 +/-0.175 0.057 +/-0.175 0.122 pCi/g MJH1 12/04/06 0656 592142 Americium-241 U 0.0454 +/-0.0873 0.0707 +/-0.0873 0.146 pCi/g Bismuth-212 0.615 +/-0.245 0.121 +/-0.245 0.257 pCi/g Bismuth-214 0.620 +/-0.100 0.0311 +/-0.100 0.0655 pCi/g Cesium-134 UI 0.00 +/-0.0349 0.0225 +/-0.0349 0.0472 pCi/g Cesium-137 0.0447 +/-0.030 0.0155 +/-0.030 0.0329 pCi/g Cobalt-60 U 0.0073 +/-0.0204 0.0176 +/-0.0204 0.0382 pCi/g Europium-152 U -0.00425 +/-0.0455 0.0407 +/-0.0455 0.085 pCi/g Europium-154 U -0.00506 +/-0.054 0.0447 +/-0.054 0.0974 pCi/g Europium-155 UI 0.00 +/-0.0815 0.0461 +/-0.0815 0.095 pCi/g Lead-212 0.910 +/-0.0889 0.0236 +/-0.0889 0.0488 pCi/g Lead-214 0.657 +/-0.0964 0.0275 +/-0.0964 0.0575 pCi/g Manganese-54 U 0.0151 +/-0.023 0.0163 +/-0.023 0.0346 pCi/g Niobium-94 U -0.00456 +/-0.0176 0.0145 +/-0.0176 0.0307 pCi/g Potassium-40 15.1 +/-1.29 0.140 +/-1.29 0.309 pCi/g Radium-226 0.620 +/-0.100 0.0311 +/-0.100 0.0655 pCi/g Silver-108m U -0.00288 +/-0.0176 0.0134 +/-0.0176 0.0283 pCi/g Thallium-208 0.302 +/-0.0513 0.017 +/-0.0513 0.0358 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 73

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-013F Project: YANK01204 Sample ID: 176890014 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

74

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-014F Project: YANK01204 Sample ID: 176890015 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 51.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.00 +/-0.184 0.0544 +/-0.184 0.116 pCi/g MJH1 12/04/06 0656 592142 Americium-241 U 0.0166 +/-0.0995 0.0678 +/-0.0995 0.139 pCi/g Bismuth-212 0.781 +/-0.286 0.105 +/-0.286 0.223 pCi/g Bismuth-214 0.659 +/-0.103 0.0288 +/-0.103 0.0604 pCi/g Cesium-134 UI 0.00 +/-0.0333 0.0186 +/-0.0333 0.0391 pCi/g Cesium-137 0.0461 +/-0.0284 0.0165 +/-0.0284 0.0347 pCi/g Cobalt-60 U -0.013 +/-0.0221 0.0146 +/-0.0221 0.0318 pCi/g Europium-152 U -0.0325 +/-0.0443 0.0385 +/-0.0443 0.0801 pCi/g Europium-154 U -0.0573 +/-0.0597 0.0457 +/-0.0597 0.0985 pCi/g Europium-155 UI 0.00 +/-0.0771 0.0479 +/-0.0771 0.0982 pCi/g Lead-212 0.908 +/-0.0882 0.0229 +/-0.0882 0.0474 pCi/g Lead-214 0.687 +/-0.0934 0.0288 +/-0.0934 0.0599 pCi/g Manganese-54 U 0.0117 +/-0.0189 0.0172 +/-0.0189 0.0361 pCi/g Niobium-94 U 0.00467 +/-0.0171 0.0147 +/-0.0171 0.0308 pCi/g Potassium-40 16.3 +/-1.35 0.119 +/-1.35 0.264 pCi/g Radium-226 0.659 +/-0.103 0.0288 +/-0.103 0.0604 pCi/g Silver-108m U 0.000199 +/-0.0156 0.0138 +/-0.0156 0.0288 pCi/g Thallium-208 0.320 +/-0.0507 0.0142 +/-0.0507 0.0299 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 75

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-014F Project: YANK01204 Sample ID: 176890015 Vol. Recv.: YANK001 Client ID:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

76

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-015F Proiect: YANKO 1204 Sample ID: 176890016 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 10.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.593 +/-0.114 0.0356 +/-0.114 0.0757 pCi/g MJH1 12/04/06 0657 592142 Americium-241 U 0.00262 +/-0.0908 0.0829 +/-0.0908 0.169 pCi/g Bismuth-212 0.375 +/-0.167 0.0893 +/-0.167 0.187 pCi/g Bismuth-214 0.405 +/-0.0598 0.0213 +/-0.0598 0.0445 pCi/g Cesium-134 U 0.0174 +/-0.0201 0.0136 +/-0.0201 0.0285 pCi/g Cesium-137 0.103 +/-0.024 0.0115 +/-0.024 0.0242 pCi/g Cobalt-60 UI 0.00 +/-0.0203 0.0125 +/-0.0203 0.0267 pCi/g Europium-152 U -0.0187 +/-0.0351 0.0301 +/-0.0351 0.0624 pCi/g Europium-154 U 0.0278 +/-0.049 0.0388 +/-0.049 0.0823 pCi/g Europium-155 U 0.0352 +/-0.0452 0.0362 +/-0.0452 0.074 pCi/g Lead-212 0.535 +/-0.0548 0.0177 +/-0.0548 0.0363 pCi/g Lead-214 0.456 +/-0.0697 0.0226 +/-0.0697 0.0467 pCi/g Manganese-54 U1 0.00 +/-0.0272 0.0112 +/-0.0272 0.0237 pCi/g Niobium-94 U 0.00293 +/-0.0121 0.0107 +/-0.0121 0.0224 pCi/g Potassium-40 10.8 +/-0.888 0.0945 +/-0.888 0.207 pCi/g Radium-226 0.405 +/-0.0598 0.0213 +/-0.0598 0.0445 pCi/g Silver-108m U -6.300E- +/-0.0124 0.0107 +/-0.0124 0.0221 pCi/g 05 Thallium-208 0.185 +/-0.0261 0.00965 +/-0.0261 0.0203 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 77

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-015F Project: YANK01204 Sample ID: 176890016 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

78

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-016F Proiect: YANK01204 Sample ID: 176890017 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 14.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.74 +/-0.296 0.0726 +/-0.296 0.152 pCi/g MJHI 12/04/06 1417 592146 Americium-241 U 0.014 +/-0.118 0.0902 +/-0.118 0.184 pCi/g Bismuth-212 0.987 +/-0.341 0.155 +/-0.341 0.323 pCi/g Bismuth-214 1.93 +/-0.215 0.034 +/-0.215 0.071 pCi/g Cesium-134 UI 0.00 +/-0.0374 0.0269 +/-0.0374 0.0558 pCi/g Cesium-137 U -0.0039 +/-0.027 0.0195 +/-0.027 0.0407 pCi/g Cobalt-60 U -0.0172 +/-0.0252 0.0196 +/-0.0252 0.042 pCi/g Europium-152 U 0.0261 +/-0.063 0.0501 +/-0.063 0.103 pCi/g Europium-154 U 0.0378 +/-0.0802 0.0686 +/-0.0802 0.145 pCi/g Europium-155 U 0.0956 +/-0.0946 0.0583 +/-0.0946 0.119 pCi/g Lead-212 1.61 +/-0.141 0.0279 +/-0.141 0.0571 pCi/g Lead-214 2.13 +/-0.211 0.0366 +/-0.211 0.0755 pCi/g Manganese-54 U -0.0195 +/-0.0246 0.0204 +/-0.0246 0.0427 pCi/g Niobium-94 U 0.0161 +/-0.0216 0.0186 +/-0.0216 0.0388 pCi/g Potassium-40 27.7 +/-2.07 0.163 +/-2.07 0.354 pCi/g Radium-226 1.93 +/-0.215 0.034 +/-0.215 0.071 pCi/g Silver-108m U -0.00721 +/-0.0197 0.0168 +/-0.0197 0.0348 pCi/g Thallium-208 0.523 +/-0.0686 0.0189 +/-0.0686 0.0394 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 79

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-016F Proiect: YANK01204 Sample ID: 176890017 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

80

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0171 Proiect: YANK01204 Sample ID: 176890018 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 39.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.05 +/-0.258 0.106 +/-0.258 0.211 pCi/g MJHI 12/04/06 1420 592146 Americium-241 U -0.0373 +/-0.0555 0.0407 +/-0.0555 0.0813 pCi/g Bismuth-212 U 0.425 +/-0.332 0.253 +/-0.332 0.506 pCi/g Bismuth-214 0.626 +/-0.135 0.0481 +/-0.135 0.0961 pCi/g Cesium-134 U 0.00613 +/-0.0485 0.0421 +/-0.0485 0.0841 pCi/g Cesium-137 0.199 +/-0.0755 0.0362 +/-0.0755 0.0724 pCi/g Cobalt-60 U 0.0391 +/-0.0494 0.0456 +/-0.0494 0.0911 pCi/g Europium-152 U -0.0955 +/-0.133 0.0784 +/-0.133 0.157 pCi/g Europium-154 U 0.0692 +/-0.121 0.0988 +/-0.121 0.197 pCi/g Europium-155 U 0.0504 +/-0.0905 0.0698 +/-0.0905 0.140 pCi/g Lead-212 0.785 +/-0.114 0.0386 +/-0.114 0.0772 pCi/g Lead-214 0.746 +/-0.158 0.0543 +/-0.158 0.109 pCi/g Manganese-54 U -6.730E- +/-0.0412 0.0352 +/-0.0412 0.0704 pCi/g 06 Niobium-94 U 0.0268 +/-0.0349 0.0323 +/-0.0349 0.0646 pCi/g Potassium-40 13.7 +/-1.51 0.241 +/-1.51 0.482 pCi/g Radium-226 0.626 +/-0.135 0.0481 +/-0.135 0.0961 pCi/g Silver-108m U-0.000933 +/-0.0359 0.0304 +/-0.0359 0.0608 pCi/g Thallium-208 0.289 +/-0.0846 0.0325 +/-0.0846 0.065 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 81

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0171 Project: YANK01204 Sample ID: 176890018 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

82

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0181 Project: YANKO01204 Sample ID: 176890019 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 27.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.639 +/-0.146 0.0441 +/-0.146 0.0972 pCi/g MJH1 12/04/06 1513 592146 Americium-241 U 0.0374 +/-0.0698 0.0633 +/-0.0698 0.131 pCi/g Bismuth-212 0.647 +/-0.269 0.117 +/-0.269 0.251 pCi/g Bismuth-214 0.431 +/-0.0915 0.0247 +/-0.0915 0.0532 pCi/g Cesium-134 U 0.0249 +/-0.0312 0.0168 +/-0.0312 0.0362 pCi/g Cesium-137 0.0883 +/-0.0237 0.0137 +/-0.0237 0.0295 pCi/g Cobalt-60 U -0.00418 +/-0.0186 0.0157 +/-0.0186 0.0348 pCi/g Europium-152 U -0.0137 +/-0.043 0.0365 +/-0.043 0.0771 pCi/g Europium-154 U -0.0307 +/-0.0505 0.0406 +/-0.0505 0.0906 pCi/g Europium-155 U 0.0311 +/-0.0436 0.0425 +/-0.0436 0.0882 pCi/g Lead-212 0.583 +/-0.0687 0.0246 +/-0.0687 0.0512 pCi/g Lead-214 0.457 +/-0.0821 0.0282 +/-0.0821 0.0595 pCi/g Manganese-54 U 0.00253 +/-0.0162 0.0142 +/-0.0162 0.0307 pCi/g Niobium-94 U 0.00914 +/-0.0214 0.015 +/-0.0214 0.032 pCi/g Potassium-40 9.56 +/-1.01 0.116 +/-1.01 0.267 pCi/g Radium-226 0.431 +/-0.0915 0.0247 +/-0.0915 0.0532 pCi/g Silver-108m U -0.0135 +/-0.0133 0.0112 +/-0.0133 0.024 pCi/g Thallium-208 0.211 +/-0.0401 0.0128 +/-0.0401 0.0276 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 83

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0181 Project: YANK01204 Sample ID: 176890019 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product 13 Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

84

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0191 Project: YANK01204 Sample ID: 176890020 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 36.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.709 +/-0.169 0.0536 +/-0.169 0.116 pCi/g MJHI 12/04/06 1520 592146 Americium-241 U 0.0591 +/-0.0845 0.0689 +/-0.0845 0.142 pCi/g Bismuth-212 0.670 +/-0.256 0.111 +/-0.256 0.238 pCi/g Bismuth-214 0.439 +/-0.0714 0.0277 +/-0.0714 0.059 pCi/g Cesium-134 U 0.0402 +/-0.0211 0.0211 +/-0.0211 0.0446 pCi/g Cesium-137 0.106 +/-0.034 0.0158 +/-0.034 0.0336 pCi/g Cobalt-60 U -0.0166 +/-0.0264 0.0175 +/-0.0264 0.0382 pCi/g Europium-152 U 0.0209 +/-0.0493 0.044 +/-0.0493 0.0921 pCi/g Europium-154 U -0.0235 +/-0.0628 0.0522 +/-0.0628 0.113 pCi/g Europium-155 U 0.0116 +/-0.0509 0.0465 +/-0.0509 0.096 pCi/g Lead-212 0.586 +/-0.0554 0.0242 +/-0.0554 0.0503 pCi/g Lead-214 0.458 +/-0.0766 0.0287 +/-0.0766 0.0604 pCi/g Manganese-54 U -0.00284 +/-0.0196 0.0169 +/-0.0196 0.036 pCi/g Niobium-94 U 0.0208 +/-0.0181 0.0167 +/-0.0181 0.0353 pCi/g Potassium-40 9.15 +/-0.773 0.132 +/-0.773 0.297 pCi/g Radium-226 0.439 +/-0.0714 0.0277 +/-0.0714 0.059 pCi/g Silver-108m U 0.000158 +/-0.0163 0.0146 +/-0.0163 0.0308 pCi/g Thallium-208 0.209 +/-0.0401 0.016 +/-0.0401 0.0339 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 11/30/06 1435 592097 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 85

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0191 Project: YANK01204 Sample ID: 176890020 Client ID: YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

86

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0201 Project: YANK01204 Sample ID: 176890021 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 6.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A' Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.653 +/-0.116 0.0459 +/-0.116 0.100 pCi/g MJHI 12/04/06 1513 592146 Americium-241 U 0.0304 +/-0.0962 0.0827 +/-0.0962 0.172 pCi/g Bismuth-212 0.310 +/-0.146 0.097 +/-0.146 0.210 pCi/g Bismuth-214 0.460 +/-0.0714 0.0243 +/-0.0714 0.052 pCi/g Cesium-134 U 0.0224 +/-0.0252 0.0172 +/-0.0252 0.0369 pCi/g Cesium-137 0.0818 +/-0.0346 0.0153 +/-0.0346 0.0326 pCi/g Cobalt-60 U 0.0133 +/-0.0189 0.0174 +/-0.0189 0.0381 pCi/g Europium-152 U -0.0333 +/-0.0418 0.0343 +/-0.0418 0.0726 pCi/g Europium-154 U -0.00674 +/-0.0547 0.0462 +/-0.0547 0.101 pCi/g Europium-155 U 0.0667 +/-0.0453 0.0467 +/-0.0453 0.0966 pCi/g Lead-212 0.546 +/-0.0463 0.0211 +/-0.0463 0.0439 pCi/g Lead-214 0.514 +/-0.0687 0.0285 +/-0.0687 0.0599 pCi/g Manganese-54 U-0.000315 +/-0.0172 0.0146 +/-0.0172 0.0313 pCi/g Niobium-94 U 0.00315 +/-0.015 0.0133 +/-0.015 0.0284 pCi/g Potassium-40 10.3 +/-0.751 0.132 +/-0.751 0.297 pCi/g Radium-226 0.460 +/-0.0714 0.0243 +/-0.0714 0.052 pCi/g Silver-108m U 0.000752 +/-0.0147 0.0135 +/-0.0147 0.0285 pCi/g Thallium-208 0.195 +/-0.0382 0.0132 +/-0.0382 0.0282 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 87

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0201 Project: YANKO01204 Sample ID: 176890021 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

88

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0211 Project: YANK01204 Sample ID: 176890022 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 7.95%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.05 +/-0.228 0.0906 +/-0.228 0.195 pCi/g MJHI 12/04/06 1521 592146 Americium-241 U -0.00529 +/-0.0413 0.0361 +/-0.0413 0.0744 pCi/g Bismuth-212 0.739 +/-0.352 0.164 +/-0.352 0.356 pCi/g Bismuth-214 1.04 +/-0.145 0.0416 +/-0.145 0.0892 pCi/g Cesium- 134 UI 0.00 +/-0.0442 0.0342 +/-0.0442 0.0725 pCi/g Cesium-137 U 0.00502 +/-0.0292 0.0259 +/-0.0292 0.0552 pCi/g Cobalt-60 U -0.00899 +/-0.031 0.0257 +/-0.031 0.0568 pCi/g Europium-152 U 0.00144 +/-0.066 0.0612 +/-0.066 0.129 pCi/g Europium-154 U 0.0281 +/-0.0834 0.0748 +/-0.0834 0.164 pCi/g Europium-155 U 0.0859 +/-0.0882 0.0599 +/-0.0882 0.124 pCi/g Lead-212 1.13 +/-0.0794 0.0356 +/-0.0794 0.0741 pCi/g Lead-214 1.10 +/-0.124 0.0446 +/-0.124 0.0938 pCi/g Manganese-54 U 0.00713 +/-0.0275 0.024 +/-0.0275 0.0517 pCi/g Niobium-94 U -0.0189 +/-0.0248 0.020 +/-0.0248 0.0431 pCi/g Potassium-40 18.8 +/-1.29 0.209 +/-1.29 0.473 pCi/g Radium-226 1.04 +/-0.145 0.0416 +/-0.145 0.0892 pCi/g Silver-108m U 0.00551 +/-0.0224 0.0207 +/-0.0224 0.0439 pCi/g Thallium-208 0.379 +/-0.0577 0.0227 +/-0.0577 0.0486 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 89

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0211 Project: YANK01204 Sample ID: 176890022 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1l

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

90

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0221 Proiect: YANKO 1204 Sample ID: 176890023 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.47%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.85 +/-0.283 0.0622 +/-0.283 0.131 pCi/g MJHI 12/04/06 1514 592146 Americium-241 U -0.0286 +/-0.0999 0.0887 +/-0.0999 0.181 pCi/g Bismuth-212 1.12 +/-0.274 0.133 +/-0.274 0.278 pCi/g Bismuth-214 1.91 +/-0.190 0.0346 +/-0.190 0.0718 pCi/g Cesium-134 U1 0.00 +/-0.0407 0.0261 +/-0.0407 0.0539 pCi/g Cesium-137 U -0.00192 +/-0.0229 0.0201 +/-0.0229 0.0417 pCi/g Cobalt-60 U 0.0223 +/-0.0214 0.0198 +/-0.0214 0.042 pCi/g Europium-152 U -0.0474 +/-0.0576 0.0485 +/-0.0576 0.0999 pCi/g Europium-154 U -0.0583 +/-0.0672 0.0547 +/-0.0672 0.116 pCi/g Europium-155 U 0.0382 +/-0.0687 0.0559 +/-0.0687 0.114 pCi/g Lead-212 1.90 +/-0.162 0.0289 +/-0.162 0.0592 pCi/g Lead-214 2.11 +/-0.211 0.0359 +/-0.211 0.0739 pCi/g Manganese-54 U 0.0247 +/-0.0329 0.0181 +/-0.0329 0.0379 pCi/g Niobium-94 U 0.0183 +/-0.0194 0.0176 +/-0.0194 0.0366 pCi/g Potassium-40 23.5 +/-1.89 0.144 +/-1.89 0.311 pCi/g Radium-226 1.91 +/-0.190 0.0346 +/-0.190 0.0718 pCi/g Silver-108m U -0.00597 +/-0.0206 0.0173 +/-0.0206 0.0358 pCi/g Thallium-208 0.589 +/-0.0667 0.018 +/-0.0667 0.0374 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 91

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0221 Project: YANK01204 Sample ID: 176890023 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

92

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0231 Project: YANK01204 Sample ID: 176890024 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 10.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.95 +/-0.289 0.058 +/-0.289 0.121 pCi/g MJHI 12/04/06 1521 592146 Americium-241 U -0.0948 +/-0.101 0.083 +/-0.101 0.169 pCi/g Bismuth-212 1.45 +/-0.321 0.122 +/-0.321 0.254 pCi/g Bismuth-214 1.81 +/-0.185 0.0302 +/-0.185 0.0626 pCi/g Cesium-134 UI 0.00 +/-0.033 0.0243 +/-0.033 0.0501 pCi/g Cesium-137 U -0.0092 +/-0.0202 0.0168 +/-0.0202 0.0349 pCi/g Cobalt-60 U -0.0065 +/-0.0204 0.0167 +/-0.0204 0.0355 pCi/g Europium-152 U -0.0456 +/-0.0509 0.0444 +/-0.0509 0.0913 pCi/g Europium-154 U 0.0485 +/-0.0631 0.0557 +/-0.0631 0.117 pCi/g Europium-155 U 0.0522 +/-0.0813 0.0534 +/-0.0813 0.109 pCi/g Lead-212 1.88 +/-0.155 0.0269 +/-0.155 0.055 pCi/g Lead-214 1.97 +/-0.189 0.0322 +/-0.189 0.0663 pCi/g Manganese-54 U 0.00733 +/-0.0206 0.0184 +/-0.0206 0.0382 pCi/g Niobium-94 U 0.00541 +/-0.0187 0.016 +/-0.0187 0.0333 pCi/g Potassium- 4 0 25.8 +/-1.94 0.161 +/-1.94 0.342 pCi/g Radium-226 1.81 +/-0.185 0.0302 +/-0.185 0.0626 pCi/g Silver-108m U -0.00365 +/-0.0172 0.0151 +/-0.0172 0.0311 pCi/g Thallium-208 0.595 +/-0.0662 0.0163 +/-0.0662 0.0338 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 93

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0231 Proiect: YANK01204 Sample ID: 176890024 Client ID: YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

94

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company ý Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0241 Project: YANK01204 Sample ID: 176890025 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.54%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 2.04 +/-0.272 0.0448 +/-0.272 0.0923 pCi/g MJHl 12/04/06 1522 592146 Americium-241 U -0.0299 +/-0.105 0.0941 +/-0.105 0.190 pCi/g Bismuth-212 1.36 +/-0.250 0.0975 +/-0.250 0.200 pCi/g Bismuth-214 1.89 +/-0.183 0.0231 +/-0.183 0.0473 pCi/g Cesium-134 UI 0.00 +/-0.0285 0.0184 +/-0.0285 0.0376 pCi/g Cesium-137 U 0.016 +/-0.0178 0.0141 +/-0.0178 0.0288 pCi/g Cobalt-60 U 0.00115 +/-0.0165 0.0142 +/-0.0165 0.0295 pCi/g Europium-152 U -0.0129 +/-0.0407 0.0353 +/-0.0407 0.0719 pCi/g Europium-154 U 0.00975 +/-0.0519 0.0452 +/-0.0519 0.0933 pCi/g Europium-155 UI 0.00 +/-0.0574 0.0447 +/-0.0574 0.0904 pCi/g Lead-212 1.99 +/-0.165 0.0228 +/-0.165 0.0463 pCi/g Lead-214 2.18 +/-0.195 0.0245 +/-0.195 0.0499 pCi/g Manganese-54 UI 0.00 +/-0.017 0.0137 +/-0.017 0.0281 pCi/g Niobium-94 U 0.00871 +/-0.014 0.0125 +/-0.014 0.0255 pCi/g Potassium-40 28.4 +/-1.97 0.108 +/-1.97 0.227 pCi/g Radium-226 1.89 +/-0.183 0.0231 +/-0.183 0.0473 pCi/g Silver-108m U -0.0124 +/-0.0141 0.0117 +/-0.0141 0.024 pCi/g Thallium-208 0.657 +/-0.0627 0.0125 +/-0.0627 0.0256 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 95

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0241 Project: YANK01204 Sample ID: 176890025 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

96

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0251 Project: YANK01204 Sample ID: 176890026 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 8.71%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 2.50 +/-0.358 0.0741 +/-0.358 0.157 pCi/g MJHI 12/04/06 1522 592146 Americium-241 U 0.0797 +/-0.114 0.0928 +/-0.114 0.189 pCi/g Bismuth-212 1.60 +/-0.492 0.168 +/-0.492 0.354 pCi/g Bismuth-214 1.93 +/-0.226 0.045 +/-0.226 0.0937 pCi/g Cesium-134 UI 0.00 +/-0.0541 0.0358 +/-0.0541 0.0741 pCi/g Cesium-137 U 0.0242 +/-0.0332 0.0258 +/-0.0332 0.0538 pCi/g Cobalt-60 U 0.0069 +/-0.0296 0.0257 +/-0.0296 0.0548 pCi/g Europium-152 U -0.0995 +/-0.0799 0.0676 +/-0.0799 0.139 pCi/g Europium-154 U 0.0362 +/-0.0936 0.082 +/-0.0936 0.173 pCi/g Europium-155 U 0.0459 +/-0.109 0.0785 +/-0.109 0.160 pCi/g Lead-212 2.36 +/-0.205 0.0451 +/-0.205 0.0921 pCi/g Lead-214 2.24 +/-0.229 0.0463 +/-0.229 0.0957 pCi/g Manganese-54 U 0.0363 +/-0.0433 0.025 +/-0.0433 0.0524 pCi/g Niobium-94 U 0.0152 +/-0.0279 0.0243 +/-0.0279 0.0506 pCi/g Potassium-40 27.3 +/-2.01 0.188 +/-2.01 0.410 pCi/g Radium-226 1.93 +/-0.226 0.045 +/-0.226 0.0937 pCi/g Silver-108m U -0.00609 +/-0.0257 0.0223 +/-0.0257 0.0462 pCi/g Thallium-208 0.717 +/-0.088 0.025 +/-0.088 0.0519 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/30/06 1350 592098 The following Analytical Methods were performed Method Description 1 EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 97

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0251 Proiect: YANK01204 Sample ID: 176890026 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

98

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0261 Project: YANK01204 Sample ID: 176890027 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.19 +/-0.154 0.0515 +/-0.154 0.110 pCi/g MJHI 12/04/06 1523 592146 Americium-241 U -0.0228 +/-0.134 0.0801 +/-0.134 0.164 pCi/g Bismuth-212 0.945 +/-0.262 0.133 +/-0.262 0.280 pCi/g Bismuth-214 0.817 +/-0.0872 0.0347 +/-0.0872 0.0724 pCi/g Cesium-134 UI 0.00 +/-0.0287 0.023 +/-0.0287 0.048 pCi/g Cesium-137 0.0499 +/-0.0287 0.0186 +/-0.0287 0.039 pCi/g Cobalt-60 U-0.000936 +/-0.0208 0.0172 +/-0.0208 0.0371 pCi/g Europium-152 U -0.0536 +/-0.0667 0.0477 +/-0.0667 0.0987 pCi/g Europium-154 U -0.0246 +/-0.058 0.0461 +/-0.058 0.0997 pCi/g Europium-155 U 0.0687 +/-0.0563 0.0498 +/-0.0563 0.102 pCi/g Lead-212 1.23 +/-0.0634 0.0308 +/-0.0634 0.0632 pCi/g Lead-214 0.954 +/-0.0795 0.0374 +/-0.0795 0.0773 pCi/g Manganese-54 U -0.00292 +/-0.0206 0.0176 +/-0.0206 0.037 pCi/g Niobium-94 U 0.00734 +/-0.0179 0.0159 +/-0.0179 0.0334 pCi/g Potassium-40 12.6 +/-0.806 0.162 +/-0.806 0.352 pCi/g Radium-226 0.817 +/-0.0872 0.0347 +/-0.0872 0.0724 pCi/g Silver-108m U -0.0181 +/-0.0178 0.0143 +/-0.0178 0.0298 pCi/g Thallium-208 0.396 +/-0.0414 0.0195 +/-0.0414 0.0406 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 99

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0261 Project: YANK01204 Sample ID: 176890027 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

100

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0271 Project: YANK01204 Sample ID: 176890028 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 8.57%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.874 +/-0.199 0.0882 +/-0.199 0.190 pCi/g MJH1 12/04/06 1523 592146 Americium-241 U 0.0143 +/-0.0393 0.0345 +/-0.0393 0.0713 pCi/g Bismuth-212 0.807 +/-0.279 0.184 +/-0.279 0.395 pCi/g Bismuth-214 0.559 +/-0.125 0.0493 +/-0.125 0.104 pCi/g Cesium-134 UI 0.00 +/-0.0437 0.033 +/-0.0437 0.0699 pCi/g Cesium-137 U 0.0561 +/-0.0383 0.0284 +/-0.0383 0.0603 pCi/g Cobalt-60 U 0.0282 +/-0.0373 0.0263 +/-0.0373 0.0577 pCi/g Europium-152 U 0.0192 +/-0.0677 0.0605 +/-0.0677 0.127 pCi/g Europium-154 U 0.0237 +/-0.0806 0.0711 +/-0.0806 0.156 pCi/g Europium-155 U 0.0742 +/-0.0902 0.0527 +/-0.0902 0.110 pCi/g Lead-212 0.639 +/-0.0839 0.0417 +/-0.0839 0.0863 pCi/g Lead-214 0.614 +/-0.104 0.045 +/-0.104 0.0947 pCi/g Manganese-54 U 0.0169 +/-0.0319 0.0283 +/-0.0319 0.0603 pCi/g Niobium-94 U -0.00838 +/-0.0259 0.0218 +/-0.0259 0.0467 pCi/g Potassium-40 11.4 +/-1.09 0.212 +/-1.09 0.476 pCi/g Radium-226 0.559 +/-0.125 0.0493 +/-0.125 0.104 pCi/g Silver-108m U 0.00571 +/-0.0219 0.0204 +/-0.0219 0.0434 pCi/g Thallium-208 0.198 +/-0.0545 0.0251 +/-0.0545 0.0533 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 101

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analvsis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0271 Project: YANK01204 Sample ID: I7689002R Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

102

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0281 Project: YANKO1204 Sample ID: 176890029 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.31%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.677 +/-0.190 0.0629 +/-0.190 0.138 pCi/g MJHI 12/04/06 1524 592146 Americium-241 U -0.0142 +/-0.0284 0.026 +/-0.0284 0.0538 pCi/g Bismuth-212 0.710 +/-0.307 0.130 +/-0.307 0.282 pCi/g Bismuth-214 0.680 +/-0.0955 0.0286 +/-0.0955 0.062 pCi/g Cesium-134 U 0.0372 +/-0.0472 0.0237 +/-0.0472 0.0508 pCi/g Cesium-] 37 0.0951 +/-0.0362 0.023 +/-0.0362 0.0488 pCi/g Cobalt-60 U 0.0406 +/-0.0267 0.0209 +/-0.0267 0.0463 pCi/g Europium-152 U -0.0323 +/-0.0517 0.0433 +/-0.0517 0.0918 pCi/g Europium-154 U-0.000226 +/-0.070 0.0598 +/-0.070 0.132 pCi/g Europium-155 U 0.0397 +/-0.0659 0.042 +/-0.0659 0.0871 pCi/g Lead-212 0.852 +/-0.0613 0.0264 +/-0.0613 0.0552 pCi/g Lead-214 0.748 +/-0.0885 0.0328 +/-0.0885 0.0694 pCi/g Manganese-54 U 0.0161 +/-0.0246 0.020 +/-0.0246 0.043 pCi/g Niobium-94 U -0.0114 +/-0.0198 0.0163 +/-0.0198 0.0351 pCi/g Potassium-40 12.2 +/-1.02 0.161 +/-1.02 0.367 pCi/g Radium-226 0.680 +/-0.0955 0.0286 +/-0.0955 0.062 pCi/g Silver-108m U -0.00344 +/-0.0174 0.0159 +/-0.0174 0.0337 pCi/g Thallium-208 0.335 +/-0.0502 0.0179 +/-0.0502 0.0384 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 103

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0281 Project: YANK01204 Sample ID: 176890029 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

104

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0291 Project: YANK01204 Sample ID: 176890030 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 12%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 2.21 +/-0.358 0.0827 +/-0.358 0.178 pCi/g MJHI 12/04/06 1524 592146 Americium-241 U -0.0304 +/-0.0984 0.0858 +/-0.0984 0.177 pCi/g Bismuth-212 1.01 +/-0.435 0.193 +/-0.435 0.411 pCi/g Bismuth-214 1.72 +/-0.221 0.0421 +/-0.221 0.0897 pCi/g Cesium-134 UI 0.00 +/-0.056 0.0353 +/-0.056 0.0743 pCi/g Cesium-137 U 0.0143 +/-0.0323 0.0259 +/-0.0323 0.0549 pCi/g Cobalt-60 U -0.0223 +/-0.028 0.0216 +/-0.028 0.0482 pCi/g Europium-152 U -0.0553 +/-0.0846 0.0615 +/-0.0846 0.129 pCi/g Europium-154 U 0.0803 +/-0.0931 0.0864 +/-0.0931 0.186 pCi/g Europium-155 UI 0.00 +/-0.114 0.0678 +/-0.114 0.140 pCi/g Lead-212 1.90 +/-0.175 0.0417 +/-0.175 0.0862 pCi/g Lead-214 1.87 +/-0.194 0.0433 +/-0.194 0.0911 pCi/g Manganese-54 U 0.00958 +/-0.0297 0.026 +/-0.0297 0.0553 pCi/g Niobium-94 U 0.00264 +/-0.0268 0.0234 +/-0.0268 0.0496 pCi/g Potassium-40 25.4 +/-2.09 0.199 +/-2.09 0.447 pCi/g Radium-226 1.72 +/-0.221 0.0421 +/-0.221 0.0897 pCi/g Silver-108m U -0.00067 +/-0.0261 0.022 +/-0.0261 0.0463 pCi/g Thallium-208 0.655 +/-0.0822 0.0227 +/-0.0822 0.0484 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0291 Proiect: YANK01204 Sample ID: 176890030 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

106

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0301 Project: YANKO 1204 Sample ID: 176890031 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.25%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.03 +/-0.255 0.0756 +/-0.255 0.169 pCi/g MJHI 12/04/06 1524 592146 Americium-241 U 0.0188 +/-0.0364 0.0348 +/-0.0364 0.0722 pCi/g Bismuth-212 0.922 +/-0.425 0.179 +/-0.425 0.391 pCi/g Bismuth-214 0.606 +/-0.138 0.0451 +/-0.138 0.0974 pCi/g Cesium-134 U 0.0596 +/-0.0661 0.0352 +/-0.0661 0.0754 pCi/g Cesium-137 0.103 +/-0.0461 0.0244 +/-0.0461 0.0531 pCi/g Cobalt-60 U 0.0217 +/-0.0362 0.0296 +/-0.0362 0.0657 pCi/g Europium-152 U -0.028 +/-0.0569 0.0486 +/-0.0569 0.105 pCi/g Europium-154 U 0.00983 +/-0.084 0.0714 +/-0.084 0.161 pCi/g Europium-155 U 0.0401 +/-0.0889 0.0556 +/-0.0889 0.116 pCi/g Lead-212 0.884 +/-0.0736 0.0278 +/-0.0736 0.0589 pCi/g Lead-214 0.646 +/-0.111 0.049 +/-0.111 0.103 pCi/g Manganese-54 U -0.00782 +/-0.0251 0.0212 +/-0.0251 0.0469 pCi/g Niobium-94 U 0.0217 +/-0.0265 0.0254 +/-0.0265 0.0545 pCi/g Potassium-40 10.5 +/-1.28 0.247 +/-1.28 0.560 pCi/g Radium-226 0.606 +/-0.138 0.0451 +/-0.138 0.0974 pCi/g Silver-108m U -0.00369 +/-0.0221 0.019 +/-0.0221 0.041 pCi/g Thallium-208 0.245 +/-0.0495 0.0238 +/-0.0495 0.0515 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/30/06 1350 592098 The following Analytical Methods were performed Method Description 1 EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 107

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0301 Project: YANK01204 Sample ID: 176890031 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

108

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0311 Project: YANK01204 Sample ID: 176890032 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 11.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1l Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.01 +/-0.117 0.0387 +/-0.117 0.0817 pCi/g MJH1 12/04/06 1525 592146 Americium-241 U 0.0335 +/-0.090 0.0738 +/-0.090 0.152 pCi/g Bismuth-212 0.672 +/-0.182 0.0817 +/-0.182 0.172 pCi/g Bismuth-214 0.611 +/-0.072 0.0213 +/-0.072 0.0445 pCi/g Cesium-134 U 0.0311 +/-0.021 0.0163 +/-0.021 0.0338 pCi/g Cesium-137 U 0.00519 +/-0.0223 0.0138 +/-0.0223 0.0286 pCi/g Cobalt-60 U 0.0137 +/-0.0154 0.0141 +/-0.0154 0.0298 pCi/g Europium-152 U 0.0548 +/-0.0561 0.0316 +/-0.0561 0.0654 pCi/g Europium-154 U -0.0291 +/-0.0437 0.0362 +/-0.0437 0.0768 pCi/g Europium-155 U 0.0368 +/-0.046 0.044 +/-0.046 0.0901 pCi/g Lead-212 0.981 +/-0.0468 0.0183 +/-0.0468 0.0376 pCi/g Lead-214 0.729 +/-0.0606 0.0233 +/-0.0606 0.0483 pCi/g Manganese-54 U 0.0115 +/-0.0166 0.0114 +/-0.0166 0.024 pCi/g Niobium-94 U 0.0194 +/-0.0279 0.012 +/-0.0279 0.025 pCi/g Potassium-40 16.4 +/-0.704 0.115 +/-0.704 0.246 pCi/g Radium-226 0.611 +/-0.072 0.0213 +/-0.072 0.0445 pCi/g Silver-108m U 0.00747 +/-0.0118 0.0107 +/-0.0118 0.0223 pCi/g Thallium-208 0.275 +/-0.0327 0.0108 +/-0.0327 0.0227 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 109

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0311 Project: YANK01204 Sample ID: 176890032 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Nk

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

110

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0321 Project: YANK01204 Sample ID: 176890033 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 10.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.844 +/-0.190 0.0665 +/-0.190 0.145 pCi/g MJH1 12/04/06 1525 592146 Americium-241 U -0.00507 +/-0.0635 0.0565 +/-0.0635 0.117 pCi/g Bismuth-212 0.575 +/-0.283 0.166 +/-0.283 0.356 pCi/g Bismuth-214 0.575 +/-0.111 0.0359 +/-0.111 0.077 pCi/g Cesium-134 U 0.0238 +/-0.0279 0.026 +/-0.0279 0.0554 pCi/g Cesium-137 U -0.00106 +/-0.022 0.0194 +/-0.022 0.0419 pCi/g Cobalt-60 U 0.0282 +/-0.0391 0.017 +/-0.0391 0.0388 pCi/g Europium-152 U 0.00863 +/-0.0571 0.0505 +/-0.0571 0.107 pCi/g Europium-154 U -0.0352 +/-0.0675 0.0515 +/-0.0675 0.116 pCi/g Europium-155 U1 0.00 +/-0.109 0.0489 +/-0.109 0.102 pCi/g Lead-212 0.864 +/-0.095 0.0291 +/-0.095 0.061 pCi/g Lead-214 0.617 +/-0.0998 0.0411 +/-0.0998 0.0864 pCi/g Manganese-54 U 0.00448 +/-0.0214 0.0189 +/-0.0214 0.041 pCi/g Niobium-94 U 0.0117 +/-0.0195 0.0181 +/-0.0195 0.0389 pCi/g Potassium-40 14.7 +/-1.35 0.160 +/-1.35 0.367 pCi/g Radium-226 0.575 +/-0.111 0.0359 +/-0.111 0.077 pCi/g Silver-108m U 0.0085 +/-0.0205 0.0182 +/-0.0205 0.0386 pCi/g Thallium-208 0.308 +/-0.0606 0.0184 +/-0.0606 0.0396 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported ill

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0321 Project: YANKO 1204 Sample ID: 176890033 Client ID: YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF. Analyst Date Time Batch A

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

112

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0331 Project: YANK01204 Sample ID: 176890034 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.31%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.987 +/-0.149 0.0582 +/-0.149 0.124 pCi/g MJHI 12/04/06 1526 592146 Americium-241 U -0.132 +/-0.0873 0.0695 +/-0.0873 0.144 pCi/g Bismuth-212 0.650 +/-0.235 0.124 +/-0.235 0.263 pCi/g Bismuth-214 0.669 +/-0.0926 0.031 +/-0.0926 0.0655 pCi/g Cesium-134 UI 0.00 +/-0.0364 0.024 +/-0.0364 0.0503 pCi/g Cesium-] 37 U -0.00494 +/-0.0204 0.0173 +/-0.0204 0.0366 pCi/g Cobalt-60 U 0.00414 +/-0.020 0.0176 +/-0.020 0.038 pCi/g Europium-152 U 0.000151 +/-0.0505 0.0442 +/-0.0505 0.0926 pCi/g Europium-154 U -0.0336 +/-0.0638 0.0528 +/-0.0638 0.114 pCi/g Europium-155 U 0.0668 +/-0.0753 0.0547 +/-0.0753 0.113 pCi/g Lead-212 0.963 +/-0.0635 0.0269 +/-0.0635 0.0557 pCi/g Lead-214 0.764 +/-0.0884 0.0302 +/-0.0884 0.0634 pCi/g Manganese-54 U 0.0101 +/-0.0211 0.019 +/-0.0211 0.0401 pCi/g Niobium-94 U 0.0108 +/-0.019 0.0168 +/-0.019 0.0354 pCi/g Potassium-40 17.9 +/-0.874 0.112 +/-0.874 0.254 pCi/g Radium-226 0.669 +/-0.0926 0.031 +/-0.0926 0.0655 pCi/g Silver-108m U -0.00697 +/-0.0199 0.0152 +/-0.0199 0.0319 pCi/g Thallium-208 0.281 +/-0.0529 0.0168 +/-0.0529 0.0355 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 113

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0331 Project: YANKO1204 Sample ID: 176890034 Client ID: YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

114

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0341 Project: YANK01204 Sample ID: 176890035 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 8.65%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch IN Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.02 +/-0.212 0.071 +/-0.212 0.142 pCi/g MJHI 12/04/06 1519 592146 Americium-241 UI 0.00 +/-0.091 0.0805 +/-0.091 0.161 pCi/g Bismuth-212 0.666 +/-0.334 0.154 +/-0.334 0.307 pCi/g Bismuth-214 0.781 +/-0.124 0.0405 +/-0.124 0.081 pCi/g Cesium-134 UI 0.00 +/-0.0503 0.0281 +/-0.0503 0.0562 pCi/g Cesium-137 U 0.00404 +/-0.0315 0.0256 +/-0.0315 0.0511 pCi/g Cobalt-60 U -0.0246 +/-0.026 0.0191 +/-0.026 0.0381 pCi/g Europium-152 U 0.0461 +/-0.0809 0.0584 +/-0.0809 0.117 pCi/g Europium-154 U -0.0345 +/-0.081 0.0652 +/-0.081 0.130 pCi/g Europium-155 U 0.0127 +/-0.0691 0.0638 +/-0.0691 0.128 pCi/g Lead-212 0.763 +/-0.101 0.0397 +/-0.101 0.0794 pCi/g Lead-214 0.903 +/-0.122 0.0412 +/-0.122 0.0823 pCi/g Manganese-54 U 0.0124 +/-0.0262 0.021 +/-0.0262 0.042 pCi/g Niobium-94 U 0.00049 +/-0.0216 0.0193 +/-0.0216 0.0385 pCi/g Potassium-40 14.0 +/-1.32 0.167 +/-1.32 0.334 pCi/g Radium-226 0.781 +/-0.124 0.0405 +/-0.124 0.081 pCi/g Silver-108m U -0.0107 +/-0.0218 0.0186 +/-0.0218 0.0372 pCi/g Thallium-208 0.292 +/-0.0532 0.0196 +/-0.0532 0.0392 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 115

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0341 Project: YANK01204 Sample ID: 176890035 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

116

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0351 Project: YANK01204 Sample ID: 176890036 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 7.72%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.28 +/-0.222 0.0809 +/-0.222 0.162 pCi/g MJHI 12/04/06 1520 592146 Americium-241 U -0.0054 +/-0.119 0.0989 +/-0.119 0.198 pCi/g Bismuth-212 0.829 +/-0.365 0.181 +/-0.365 0.361 pCi/g Bismuth-214 1.02 +/-0.155 0.0436 +/-0.155 0.0872 pCi/g Cesium- 134 U 0.0475 +/-0.0539 0.0301 +/-0.0539 0.0602 pCi/g Cesium-137 0.0541 +/-0.0431 0.0219 +/-0.0431 0.0438 pCi/g Cobalt-60 U 0.00343 +/-0.0288 0.0248 +/-0.0288 0.0496 pCi/g Europium-152 U -0.0197 +/-0.0902 0.0658 +/-0.0902 0.132 pCi/g Europium-154 U 0.0262 +/-0.0885 0.0778 +/-0.0885 0.156 pCi/g Europium-155 U 0.114 +/-0.104 0.0726 +/-0.104 0.145 pCi/g Lead-212 1.16 +/-0.127 0.0379 +/-0.127 0.0758 pCi/g Lead-214 1.18 +/-0.159 0.0446 +/-0.159 0.0892 pCi/g Manganese-54 U -0.00673 +/-0.0265 0.023 +/-0.0265 0.046 pCi/g Niobium-94 U -0.00935 +/-0.0247 0.0205 +/-0.0247 0.041 pCi/g Potassium-40 15.0 +/-1.42 0.208 +/-1.42 0.416 pCi/g Radium-226 1.02 +/-0.155 0.0436 +/-0.155 0.0872 pCi/g Silver-108m U 0.00746 +/-0.0264 0.021 +/-0.0264 0.0419 pCi/g Thallium-208 0.347 +/-0.0734 0.0228 +/-0.0734 0.0456 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 117

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com of An~iIvs~i!~

Certificateof Analvsis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0351 Project: YANK01204 Sample ID: 176890036 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank 13D Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

118

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0361 Project: YANK01204 Sample ID: 176890037 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.12%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.981 +/-0.222 0.0622 +/-0.222 0.136 pCi/g MJHI 12/04/06 1738 592150 Americium-241 U 0.0919 +/-0.0882 0.0766 +/-0.0882 0.158 pCi/g Bismuth-212 0.446 +/-0.261 0.157 +/-0.261 0.336 pCi/g Bismuth-214 0.816 +/-0.141 0.0388 +/-0.141 0.0824 pCi/g Cesium-134 U 0.0437 +/-0.0421 0.0234 +/-0.0421 0.0502 pCi/g Cesium-137 U 0.0263 +/-0.0235 0.019 +/-0.0235 0.0409 pCi/g Cobalt-60 U 0.00625 +/-0.0252 0.0223 +/-0.0252 0.049 pCi/g Europium-152 U -0.0249 +/-0.0678 0.0518 +/-0.0678 0.109 pCi/g Europium-154 U 0.00552 +/-0.0674 0.0588 +/-0.0674 0.130 pCi/g Europium-155 U 0.0596 +/-0.0663 0.0651 +/-0.0663 0.134 pCi/g Lead-212 0.887 +/-0.0951 0.0297 +/-0.0951 0.0619 pCi/g Lead-214 0.971 +/-0.122 0.0393 +/-0.122 0.0826 pCi/g Manganese-54 U 0.0219 +/-0.0248 0.0227 +/-0.0248 0.0483 pCi/g Niobium-94 U 0.0299 +/-0.0216 0.0206 +/-0.0216 0.0437 pCi/g Potassium-40 13.5 +/-1.25 0.170 +/-1.25 0.385 pCi/g Radium-226 0.816 +/-0.141 0.0388 +/-0.141 0.0824 pCi/g Silver-108m U -0.00544 +/-0.0204 0.0179 +/-0.0204 0.038 pCi/g Thallium-208 0.289 +/-0.0467 0.023 +/-0.0467 0.0487 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 119

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0361 Project: YANKO01204 Sample ID: 176890037 Client ID: YANK00I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

120

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0371 Project: YANK01204 Sample ID: 176890038 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 11.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.799 +/-0.148 0.0493 +/-0.148 0.107 pCi/g MJH1 12/04/06 1738 592150 Americium-241 U 0.0359 +/-0.130 0.0824 +/-0.130 0.169 pCi/g Bismuth-212 0.669 +/-0.274 0.116 +/-0.274 0.249 pCi/g Bismuth-214 0.681 +/-0.0805 0.0323 +/-0.0805 0.0682 pCi/g Cesium-134 UI 0.00 +/-0.0324 0.022 +/-0.0324 0.0465 pCi/g Cesium-137 0.123 +/-0.0277 0.0164 +/-0.0277 0.0349 pCi/g Cobalt-60 U 0.0335 +/-0.0221 0.0214 +/-0.0221 0.046 pCi/g Europium-152 U 0.0469 +/-0.103 0.0456 +/-0.103 0.0953 pCi/g Europium-154 U 0.00121 +/-0.0646 0.0541 +/-0.0646 0.117 pCi/g Europium-155 U 0.0254 +/-0.0678 0.0568 +/-0.0678 0.117 pCi/g Lead-212 0.752 +/-0.0566 0.0267 +/-0.0566 0.0553 pCi/g Lead-214 0.728 +/-0.0774 0.0301 +/-0.0774 0.0632 pCi/g Manganese-54 U 0.00273 +/-0.0193 0.017 +/-0.0193 0.0361 pCi/g Niobium-94 U -0.00628 +/-0.0178 0.0152 +/-0.0178 0.0323 pCi/g Potassium-40 11.3 +/-0.790 0.143 +/-0.790 0.320 pCi/g Radium-226 0.681 +/-0.0805 0.0323 +/-0.0805 0.0682 pCi/g Silver-108m U 0.00794 +/-0.0218 0.0156 +/-0.0218 0.0328 pCi/g Thallium-208 0.226 +/-0.037 0.0184 +/-0.037 0.0388 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 121

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0371 Project: YANK01204 Sample ID: 176890038 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

122

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0381 Project: YANK01204 Sample ID: 176890039 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.18%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.936 +/-0.200 0.102 +/-0.200 0.218 pCi/g MJH1 12/04/06 1738 592150 Americium-241 U -0.0132 +/-0.041 0.0378 +/-0.041 0.078 pCi/g Bismuth-212 0.921 +/-0.476 0.200 +/-0.476 0.428 pCi/g Bismuth-214 0.817 +/-0.121 0.0484 +/-0.121 0.103 pCi/g Cesium-134 U -0.00112 +/-0.0343 0.0293 +/-0.0343 0.0625 pCi/g Cesium-137 U 0.0365 +/-0.0471 0.0264 +/-0.0471 0.0562 pCi/g Cobalt-60 U 0.0512 +/-0.0337 0.033 +/-0.0337 0.0711 pCi/g Europium-152 U -0.0439 +/-0.0728 0.0613 +/-0.0728 0.129 pCi/g Europium-154 U -0.0336 +/-0.0968 0.0795 +/-0.0968 0.173 pCi/g Europium-155 U 0.0549 +/-0.0681 0.0628 +/-0.0681 0.130 pCi/g Lead-212 0.709 +/-0.0903 0.0515 +/-0.0903 0.106 pCi/g Lead-214 0.857 +/-0.113 0.0449 +/-0.113 0.0944 pCi/g Manganese-54 U 0.0253 +/-0.0448 0.0248 +/-0.0448 0.0531 pCi/g Niobium-94 U 0.00387 +/-0.0284 0.0249 +/-0.0284 0.0529 pCi/g Potassium-40 13.3 +/-1.11 0.190 +/-1.11 0.430 pCi/g Radium-226 0.817 +/-0.121 0.0484 +/-0.121 0.103 pCi/g Silver-108m U-0.000356 +/-0.024 0.022 +/-0.024 0.0465 pCi/g Thallium-208 0.253 +/-0.0524 0.0216 +/-0.0524 0.0464 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 123

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0381 Project: YANK0 1204 Sample ID: 176890039 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

124

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0391 Project: YANKO 1204 Sample ID: 176890040 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.95%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.32 +/-0.228 0.0779 +/-0.228 0.169 pCi/g MJHI 12/04/06 1739 592150 Americium-241 U 0.0423 +/-0.0377 0.0357 +/-0.0377 0.0732 pCi/g Bismuth-212 0.725 +/-0.293 0.186 +/-0.293 0.396 pCi/g Bismuth-214 1.28 +/-0.129 0.0443 +/-0.129 0.094 pCi/g Cesium-134 U 0.046 +/-0.0481 0.0317 +/-0.0481 0.067 pCi/g Cesium-137 U 0.0406 +/-0.0411 0.031 +/-0.0411 0.0652 pCi/g Cobalt-60 U -0.00638 +/-0.0288 0.0236 +/-0.0288 0.0523 pCi/g Europium-152 U -0.0369 +/-0.069 0.0575 +/-0.069 0.121 pCi/g Europium-154 U -0.0135 +/-0.109 0.0788 +/-0.109 0.171 pCi/g Europium-155 U 0.0838 +/-0.0876 0.0534 +/-0.0876 0.110 pCi/g Lead-212 1.43 +/-0.0814 0.034 +/-0.0814 0.0706 pCi/g Lead-214 1.58 +/-0.120 0.039 +/-0.120 0.0821 pCi/g Manganese-54 U 0.0469 +/-0.0319 0.0276 +/-0.0319 0.0585 pCi/g Niobium-94 U 0.0254 +/-0.0274 0.0251 +/-0.0274 0.0531 pCi/g Potassium-40 17.8 +/-1.28 0.235 +/-1.28 0.521 pCi/g Radium-226 1.28 +/-0.129 0.0443 +/-0.129 0.094 pCi/g Silver-108m U 0.00274 +/-0.0222 0.0203 +/-0.0222 0.0428 pCi/g Thallium-208 0.489 +/-0.0716 0.0242 +/-0.0716 0.0512 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1350 592098 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 125

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis 1 Certiicatefit Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0391 Proiect: YANK01204 Sample ID: 176890040 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

126

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0401 Proiect: YANK01204 Sample ID: 176890041 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.18%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gamma Spec Analysis Gamma,Solid-FSSGAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.28 +/-0.256 0.0663 +/-0.256 0.145 pCi/g MJHI 12/04/06 1739 592150 Americium-241 U 0.0365 +/-0.0785 0.0714 +/-0.0785 0.148 pCi/g Bismuth-212 0.862 +/-0.321 0.141 +/-0.321 0.306 pCi/g Bismuth-214 1.08 +/-0.172 0.0386 +/-0.172 0.0825 pCi/g Cesium-134 U 0.0515 +/-0.0379 0.0265 +/-0.0379 0.0566 pCi/g Cesium-137 0.0766 +/-0.0346 0.0195 +/-0.0346 0.0421 pCi/g Cobalt-60 U 0.00341 +/-0.0255 0.0223 +/-0.0255 0.0493 pCi/g Europium-152 U 0.0359 +/-0.0606 0.0547 +/-0.0606 0.115 pCi/g Europium-154 U -0.0131 +/-0.0813 0.0691 +/-0.0813 0.151 pCi/g Europium-155 U 0.0632 +/-0.0827 0.0594 +/-0.0827 0.123 pCi/g Lead-212 1.08 +/-0.113 0.0329 +/-0.113 0.0684 pCi/g Lead-214 1.36 +/-0.168 0.0336 +/-0.168 0.0715 pCi/g Manganese-54 U 0.0205 +/-0.0226 0.0188 +/-0.0226 0.0409 pCi/g Niobium-94 U -0.00111 +/-0.0203 0.0176 +/-0.0203 0.038 pCi/g Potassium-40 14.2 +/-1.42 0.182 +/-1.42 0.412 pCi/g Radium-226 1.08 +/-0.172 0.0386 +/-0.172 0.0825 pCi/g Silver-108m U -0.0199 +/-0.0211 0.0163 +/-0.0211 0.035 pCi/g Thallium-208 0.393 +/-0.0627 0.0188 +/-0.0627 0.0404 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1334 592099 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 127

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0401 Proiect: YANK01204 Sample ID: 176890041 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

128

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0411 Proiect: YANK01204 Sample ID: 176890042 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.83%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.70 +/-0.328 0.104 +/-0.328 0.226 pCi/g MJHI 12/04/06 1739 592150 Americium-241 U 0.0115 +/-0.051 0.0438 +/-0.051 0.0904 pCi/g Bismuth-212 1.29 +/-0.596 0.218 +/-0.596 0.471 pCi/g Bismuth-214 1.52 +/-0.154 0.0561 +/-0.154 0.120 pCi/g Cesium-134 UI 0.00 +/-0.072 0.0276 +/-0.072 0.0605 pCi/g Cesium-137 0.0675 +/-0.039 0.0309 +/-0.039 0.0662 pCi/g Cobalt-60 U -0.00928 +/-0.0373 0.0296 +/-0.0373 0.0663 pCi/g Europium-152 U -0.0112 +/-0.0797 0.070 +/-0.0797 0.148 pCi/g Europium-154 U -0.0203 +/-0.109 0.0878 +/-0.109 0.195 pCi/g Europium-155 U 0.108 +/-0.115 0.0646 +/-0.115 0.134 pCi/g Lead-212 1.62 +/-0.101 0.0375 +/-0.101 0.0784 pCi/g Lead-214 1.56 +/-0.154 0.0507 +/-0.154 0.107 pCi/g Manganese-54 U 0.00498 +/-0.0384 0.0338 +/-0.0384 0.0723 pCi/g Niobium-94 U -0.00242 +/-0.0315 0.0278 +/-0.0315 0.0596 pCi/g Potassium-40 17.8 +/-1.59 0.247 +/-1.59 0.565 pCi/g Radium-226 1.52 +/-0.154 0.0561 +/-0.154 0.120 pCi/g Silver-108m U 0.00204 +/-0.028 0.0244 +/-0.028 0.0519 pCi/g Thallium-208 0.482 +/-0.0811 0.0319 +/-0.0811 0.0678 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1334 592099 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 129

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0411 Project: YANK01204 Sample ID: 176890042 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

130

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0421 Project: YANK01204 Sample ID: 176890043 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.71%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.74 +/-0.222 0.035 +/-0.222 0.070 pCi/g MJHI 12/06/06 1920 592150 Americium-241 U 0.100 +/-0.0847 0.0723 +/-0.0847 0.145 pCi/g Bismuth-212 0.943 +/-0.188 0.0741 +/-0.188 0.148 pCi/g Bismuth-214 1.56 +/-0.157 0.0184 +/-0.157 0.0369 pCi/g Cesium-134 UI 0.00 +/-0.0184 0.0132 +/-0.0184 0.0263 pCi/g Cesium-137 0.0294 +/-0.016 0.00943 +/-0.016 0.0189 pCi/g Cobalt-60 U 0.00287 +/-0.0151 0.0104 +/-0.0151 0.0209 pCi/g Europium-152 U -0.0303 +/-0.0385 0.0285 +/-0.0385 0.057 pCi/g Europium-154 U -0.0336 +/-0.0411 0.0297 +/-0.0411 0.0594 pCi/g Europium-155 U 0.0657 +/-0.0489 0.0408 +/-0.0489 0.0816 pCi/g Lead-212 1.64 +/-0.134 0.0174 +/-0.134 0.0348 pCi/g Lead-214 1.82 +/-0.161 0.0202 +/-0.161 0.0404 pCi/g Manganese-54 UI 0.00 +/-0.0152 0.00982 +/-0.0152 0.0196 pCi/g Niobium-94 U 0.00851 +/-0.0113 0.00949 +/-0.0113 0.019 pCi/g Potassium-40 22.3 +/-1.37 0.0825 +/-1.37 0.165 pCi/g Radium-226 1.56 +/-0.157 0.0184 +/-0.157 0.0369 pCi/g Silver-108m U -0.00635 +/-0.0113 0.00912 +/-0.0113 0.0182 pCi/g Thallium-208 0.496 +/-0.0465 0.0097 +/-0.0465 0.0194 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/30/06 1334 592099 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 2 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria 131

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0421 Project: YANK01204 Sample ID: 176890043 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

132

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0431 Project: YANKO 1204 Sample ID: 176890044 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch l1 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.88 +/-0.355 0.086 +/-0.355 0.187 pCi/g MJHI 12/04/06 1740 592150 Americium-241 U -0.0416 +/-0.096 0.0803 +/-0.096 0.166 pCi/g Bismuth-212 1.39 +/-0.424 0.198 +/-0.424 0.424 pCi/g Bismuth-214 1.73 +/-0.226 0.0482 +/-0.226 0.103 pCi/g Cesium-134 UI 0.00 +/-0.0449 0.0402 +/-0.0449 0.0847 pCi/g Cesium-137 U -0.0174 +/-0.0311 0.0259 +/-0.0311 0.0553 pCi/g Cobalt-60 U 0.0426 +/-0.0805 0.0275 +/-0.0805 0.0606 pCi/g Europium-152 U -0.00908 +/-0.0851 0.072 +/-0.0851 0.151 pCi/g Europium-154 U 0.0314 +/-0.101 0.0858 +/-0.101 0.187 pCi/g Europium-155 U 0.055 +/-0.0803 0.0752 +/-0.0803 0.156 pCi/g Lead-212 1.72 +/-0.168 0.0406 +/-0.168 0.0845 pCi/g Lead-214 1.99 +/-0.212 0.0482 +/-0.212 0.102 pCi/g Manganese-54 U -0.0234 +/-0.0364 0.0252 +/-0.0364 0.0541 pCi/g Niobium-94 U 0.0409 +/-0.0286 0.0271 +/-0.0286 0.0575 pCi/g Potassium-40 22.9 +/-2.04 0.226 +/-2.04 0.508 pCi/g Radium-226 1.73 +/-0.226 0.0482 +/-0.226 0.103 pCi/g Silver-108m U -0.00242 +/-0.0285 0.0237 +/-0.0285 0.0501 pCi/g Thallium-208 0.636 +/-0.0923 0.0222 +/-0.0923 0.0478 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1334 592099 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • g A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 133

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0431 Project: YANKO 1204 Sample ID: 176890044 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

134

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0441 Project: YANK01204 Sample ID: 176890045 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 28-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 8.74%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 2.16 +/-0.192 0.0665 +/-0.192 0.139 pCi/g MJHI 12/04/06 1740 592150 Americium-241 U 0.0522 +/-0.0968 0.0826 +/-0.0968 0.168 pCi/g Bismuth-212 1.63 +/-0.385 0.148 +/-0.385 0.308 pCi/g Bismuth-214 1.95 +/-0.122 0.0349 +/-0.122 0.0723 pCi/g Cesium-134 UI 0.00 +/-0.0324 0.0253 +/-0.0324 0.0523 pCi/g Cesium-137 U 0.0261 +/-0.0336 0.0211 +/-0.0336 0.0436 pCi/g Cobalt-60 U -0.00671 +/-0.0217 0.0182 +/-0.0217 0.0385 pCi/g Europium-152 U -0.0226 +/-0.0593 0.0505 +/-0.0593 0.104 pCi/g Europium-154 U -0.0264 +/-0.0693 0.0584 +/-0.0693 0.123 pCi/g Europium-155 UI 0.00 +/-0.115 0.0608 +/-0.115 0.124 pCi/g Lead-212 2.06 +/-0.0785 0.0304 +/-0.0785 0.0622 pCi/g Lead-214 2.27 +/-0.113 0.0344 +/-0.113 0.071 pCi/g Manganese-54 U 0.00519 +/-0.0251 0.0191 +/-0.0251 0.0397 pCi/g Niobium-94 U 0.0049 +/-0.0262 0.0176 +/-0.0262 0.0365 pCi/g Potassium-40 22.6 +/-0.915 0.152 +/-0.915 0.326 pCi/g Radium-226 1.95 +/-0.122 0.0349 +/-0.122 0.0723 pCi/g Silver-108m U 0.0113 +/-0.0195 0.0177 +/-0.0195 0.0366 pCi/g Thallium-208 0.632 +/-0.0586 0.0183 +/-0.0586 0.0379 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1334 592099 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 135

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0441 Proiect: YANK01204 Sample ID: 176890045 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

136

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0451 Project: YANK01204 Sample ID: 176890046 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 11.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 2.02 +/-0.323 0.0756 +/-0.323 0.151 pCi/g MJH1 12/04/06 1743 592150 Americium-241 U 0.104 +/-0.103 0.0853 +/-0.103 0.171 pCi/g Bismuth-212 1.22 +/-0.366 0.169 +/-0.366 0.339 pCi/g Bismuth-214 1.62 +/-0.192 0.0415 +/-0.192 0.0829 pCi/g Cesium-134 UI 0.00 +/-0.0334 0.0303 +/-0.0334 0.0606 pCi/g Cesium-137 U 0.0266 +/-0.0307 0.024 +/-0.0307 0.0479 pCi/g Cobalt-60 U 0.00643 +/-0.0274 0.0234 +/-0.0274 0.0468 pCi/g Europium-152 U -0.0945 +/-0.0888 0.0602 +/-0.0888 0.120 pCi/g Europium-154 U -0.0508 +/-0.088 0.0708 +/-0.088 0.141 pCi/g Europium-155 U 0.0353 +/-0.0741 0.0699 +/-0.0741 0.140 pCi/g Lead-212 1.93 +/-0.172 0.0375 +/-0.172 0.075 pCi/g Lead-214 1.93 +/-0.207 0.0428 +/-0.207 0.0855 pCi/g Manganese-54 U 0.00956 +/-0.0274 0.0243 +/-0.0274 0.0486 pCi/g Niobium-94 U 0.0361 +/-0.0289 0.0229 +/-0.0289 0.0458 pCi/g Potassium-40 24.2 +/-1.83 0.187 +/-1.83 0.374 pCi/g Radium-226 1.62 +/-0.192 0.0415 +/-0.192 0.0829 pCi/g Silver-108m U -0.0105 +/-0.0238 0.0204 +/-0.0238 0.0407 pCi/g Thallium-208 0.576 +/-0.0768 0.0217 +/-0.0768 0.0433 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1334 592099 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 137

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0451 Project: YANK01204 Sample ID: 176890046 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

138

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0461 Project: YANK01204 Sample ID: 176890047 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 8.84%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 2.52 +/-0.306 0.0598 +/-0.306 0.120 pCi/g MJH1 12/04/06 1744 592150 Americium-241 U 0.0796 +/-0.0932 0.073 +/-0.0932 0.146 pCi/g Bismuth-212 1.59 +/-0.280 0.133 +/-0.280 0.266 pCi/g Bismuth-214 1.96 +/-0.184 0.0318 +/-0.184 0.0635 pCi/g Cesium-134 UI 0.00 +/-0.0401 0.0236 +/-0.0401 0.0471 pCi/g Cesium-137 U 0.0245 +/-0.0258 0.0153 +/-0.0258 0.0307 pCi/g Cobalt-60 U -0.00821 +/-0.0202 0.0165 +/-0.0202 0.033 pCi/g Europium-152 U -0.0521 +/-0.0652 0.0478 +/-0.0652 0.0954 pCi/g Europium-154 U 0.00745 +/-0.0801 0.0565 +/-0.0801 0.113 pCi/g Europium-155 U 0.101 +/-0.0756 0.0542 +/-0.0756 0.108 pCi/g Lead-212 2.51 +/-0.216 0.0267 +/-0.216 0.0534 pCi/g Lead-214 2.24 +/-0.209 0.0328 +/-0.209 0.0656 pCi/g Manganese-54 U 0.0262 +/-0.0235 0.0181 +/-0.0235 0.0362 pCi/g Niobium-94 U 0.015 +/-0.0192 0.0164 +/-0.0192 0.0328 pCi/g Potassium-40 29.0 +/-1.94 0.146 +/-1.94 0.291 pCi/g Radium-226 1.96 +/-0.184 0.0318 +/-0.184 0.0635 pCi/g Silver-108m U 0.0105 +/-0.0184 0.016 +/-0.0184 0.032 pCi/g Thallium-208 0.771 +/-0.0742 0.016 +/-0.0742 0.0319 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1334 592099 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 139

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0461 Project: YANK01204 Sample ID: 176890047 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

140

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0471 Project: YANK0 1204 Sample ID: 176890048 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 11.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.92 +/-0.181 0.0624 +/-0.181 0.131 pCi/g MJH1 12/05/06 0909 592150 Americium-241 U -0.0334 +/-0.102 0.0892 +/-0.102 0.182 pCi/g Bismuth-212 1.02 +/-0.310 0.129 +/-0.310 0.269 pCi/g Bismuth-214 1.69 +/-0.103 0.0307 +/-0.103 0.0639 pCi/g Cesium-134 UI 0.00 +/-0.0344 0.0252 +/-0.0344 0.0522 pCi/g Cesium-137 U 0.0204 +/-0.0226 0.0172 +/-0.0226 0.0359 pCi/g Cobalt-60 U 0.00231 +/-0.0213 0.0182 +/-0.0213 0.0387 pCi/g Europium-152 U -0.0208 +/-0.0525 0.0442 +/-0.0525 0.0912 pCi/g Europium-154 U -0.0471 +/-0.0643 0.0518 +/-0.0643 0.110 pCi/g Europium-155 UI 0.00 +/-0.0832 0.0515 +/-0.0832 0.105 pCi/g Lead-212 1.82 +/-0.0679 0.0265 +/-0.0679 0.0543 pCi/g Lead-214 1.79 +/-0.102 0.0324 +/-0.102 0.0668 pCi/g Manganese-54 U 0.0227 +/-0.0281 0.0172 +/-0.0281 0.0359 pCi/g Niobium-94 U 0.0155 +/-0.0186 0.0166 +/-0.0186 0.0345 pCi/g Potassium-40 24.0 +/-0.934 0.152 +/-0.934 0.327 pCi/g Radium-226 1.69 +/-0.103 0.0307 +/-0.103 0.0639 pCi/g Silver-108m U -0.00126 +/-0.0165 0.0148 +/-0.0165 0.0306 pCi/g Thallium-208 0.585 +/-0.045 0.0184 +/-0.045 0.0381 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1334 592099 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 141

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0471 Project: YANK01204 Sample ID: 176890048 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

142

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0481 Proiect: YANK01204 Sample ID: 176890049 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.64%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 2.49 +/-0.237 0.0756 +/-0.237 0.158 pCi/g MJHI 12/05/06 0910 592150 Americium-241 U 0.016 +/-0.103 0.0962 +/-0.103 0.196 pCi/g Bismuth-212 1.54 +/-0.381 0.167 +/-0.381 0.348 pCi/g Bismuth-214 1.59 +/-0.121 0.0392 +/-0.121 0.0812 pCi/g Cesium-134 UI 0.00 +/-0.0438 0.0312 +/-0.0438 0.0643 pCi/g Cesium-137 U 0.0303 +/-0.0264 0.0237 +/-0.0264 0.049 pCi/g Cobalt-60 U 0.00558 +/-0.0283 0.0245 +/-0.0283 0.0516 pCi/g Europium-152 U 0.00784 +/-0.0681 0.059 +/-0.0681 0.121 pCi/g Europium-154 U -0.00778 +/-0.0837 0.0715 +/-0.0837 0.150 pCi/g Europium-155 UI 0.00 +/-0.0922 0.0662 +/-0.0922 0.135 pCi/g Lead-212 2.28 +/-0.0875 0.0342 +/-0.0875 0.0699 pCi/g Lead-214 1.91 +/-0.114 0.0403 +/-0.114 0.0829 pCi/g Manganese-54 UI 0.00 +/-0.0517 0.0213 +/-0.0517 0.0444 pCi/g Niobium-94 U 0.00333 +/-0.024 0.0204 +/-0.024 0.0423 pCi/g Potassium-40 23.6 +/-1.08 0.173 +/-1.08 0.373 pCi/g Radium-226 1.59 +/-0.121 0.0392 +/-0.121 0.0812 pCi/g Silver-108m U -0.00141 +/-0.0226 0.0201 +/-0.0226 0.0414 pCi/g Thallium-208 0.715 +/-0.059 0.0226 +/-0.059 0.0467 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1334 592099 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 143

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton. Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0481 Project: YANKO01204 Sample ID: 176890049 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

144

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0491 Proiect: YANK01204 Sample ID: 176890050 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.51%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 2.96 +/-0.340 0.0975 +/-0.340 0.211 pCi/g MJH1 12/05/06 0911 592150 Americium-241 U -0.00328 +/-0.0537 0.0506 +/-0.0537 0.104 pCi/g Bismuth-212 2.07 +/-0.643 0.229 +/-0.643 0.488 pCi/g Bismuth-214 1.82 +/-0.190 0.0594 +/-0.190 0.125 pCi/g Cesium-134 UI 0.00 +/-0.0764 0.0497 +/-0.0764 0.104 pCi/g Cesium-137 U 0.00181 +/-0.045 0.0341 +/-0.045 0.072 pCi/g Cobalt-60 U 0.0126 +/-0.0393 0.0346 +/-0.0393 0.0753 pCi/g Europium-152 U -0.0827 +/-0.0919 0.0798 +/-0.0919 0.167 pCi/g Europium-154 U -0.0223 +/-0.115 0.0829 +/-0.115 0.182 pCi/g Europium-155 UI 0.00 +/-0.107 0.0818 +/-0.107 0.168 pCi/g Lead-212 2.80 +/-0.126 0.051 +/-0.126 0.105 pCi/g Lead-214 1.95 +/-0.167 0.0559 +/-0.167 0.117 pCi/g Manganese-54 U 0.050 +/-0.0427 0.0314 +/-0.0427 0.0669 pCi/g Niobium-94 U 0.0294 +/-0.0345 0.0313 +/-0.0345 0.0662 pCi/g Potassium-40 23.8 +/-1.51 0.297 +1-1.51 0.656 pCi/g Radium-226 1.82 +/-0.190 0.0594 +/-0.190 0.125 pCi/g Silver-108m U 0.0164 +/-0.0306 0.0281 +/-0.0306 0.0591 pCi/g Thallium-208 0.830 +/-0.0986 0.033 +/-0.0986 0.0696 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/30/06 1334 592099 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 145

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0491 Project: YANKO1204 Sample ID: 176890050 Client ID: YANKO0I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample 14 Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

146

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0501 Proiect: YANK01204 Sample ID: 176890051 Client ID: YANKOOI Matrix: TS Vol. Recv.:

Collect Date: 29-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.95%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 2.26 +/-0.335 0.0653 +/-0.335 0.136 pCi/g MJH1 12/05/06 0911 592150 Americium-241 U -0.044 +/-0.111 0.0875 +/-0.111 0.178 pCi/g Bismuth-212 1.22 +/-0.357 0.137 +/-0.357 0.285 pCi/g Bismuth-214 1.89 +/-0.215 0.0313 +/-0.215 0.065 pCi/g Cesium-134 UI 0.00 +/-0.0407 0.0255 +/-0.0407 0.0526 pCi/g Cesium-137 U 0.000828 +/-0.0247 0.0184 +/-0.0247 0.0383 pCi/g Cobalt-60 U 0.00343 +/-0.0231 0.0195 +/-0.0231 0.0412 pCi/g Europium-152 U -0.00857 +/-0.0529 0.0477 +/-0.0529 0.098 pCi/g Europium-154 U -0.067 +/-0.0677 0.0526 +/-0.0677 0.111 pCi/g Europium-155 UI 0.00 +/-0.0778 0.054 +/-0.0778 0.110 pCi/g Lead-212 1.97 +/-0.165 0.0309 +/-0.165 0.0629 pCi/g Lead-214 2.00 +/-0.193 0.0332 +/-0.193 0.0684 pCi/g Manganese-54 U 0.0315 +/-0.0229 0.0191 +/-0.0229 0.0397 pCi/g Niobium-94 U 0.0283 +/-0.021 0.0187 +/-0.021 0.0387 pCi/g Potassium-40 26.3 +/-1.91 0.166 +/-1.91 0.354 pCi/g Radium-226 1.89 +/-0.215 0.0313 +/-0.215 0.065 pCi/g Silver-108m U -0.00243 +/-0.0183 0.0161 +/-0.0183 0.0333 pCi/g Thallium-208 0.629 +/-0.0763 0.0174 +/-0.0763 0.0362 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 11/30/06 1334 592099 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 147

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0501 Project: YANK01204 Sample ID: 176890051 Client ID: YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

148

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0511 Project: YANKO 1204 Sample ID: 176890052 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 29-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.85 +/-0.305 0.0634 +/-0.305 0.133 pCi/g MJH1 12/05/06 0912 592150 Americium-241 U 0.0244 +/-0.107 0.0884 +/-0.107 0.180 pCi/g Bismuth-212 1.26 +/-0.307 0.139 +/-0.307 0.289 pCi/g Bismuth-214 1.84 +/-0.200 0.0347 +/-0.200 0.0719 pCi/g Cesium-134 UI 0.00 +/-0.0416 0.0264 +/-0.0416 0.0545 pCi/g Cesium-137 U 0.0084 +/-0.0195 0.0213 +/-0.0195 0.0441 pCi/g Cobalt-60 U 0.0173 +/-0.0223 0.0197 +/-0.0223 0.0417 pCi/g Europium-152 U -0.0403 +/-0.0553 0.0478 +/-0.0553 0.0984 pCi/g Europium-154 U 0.00386 +/-0.0827 0.0602 +/-0.0827 0.127 pCi/g Europium-155 U 0.0692 +/-0.0646 0.0588 +/-0.0646 0.120 pCi/g Lead-212 1.86 +/-0.156 0.0275 +/-0.156 0.0563 pCi/g Lead-214 2.15 +/-0.202 0.0359 +/-0.202 0.0739 pCi/g Manganese-54 U 0.0123 +/-0.0301 0.0191 +/-0.0301 0.0398 pCi/g Niobium-94 U 0.0032 +/-0.0208 0.0175 +/-0.0208 0.0363 pCi/g Potassium-40 27.6 +/-2.11 0.165 +/-2.11 0.353 pCi/g Radium-226 1.84 +/-0.200 0.0347 +/-0.200 0.0719 pCi/g Silver-108m U 0.0137 +/-0.0187 0.0167 +/-0.0187 0.0346 pCi/g Thallium-208 0.653 +/-0.0755 0.0168 +/-0.0755 0.035 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 11/30/06 1334 592099 The following Analytical Methods were performed Method Description I EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported 149

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 7, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0511 Project: YANKO 1204 Sample ID: 176890052 Client ID: YANKOOl Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC[MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

150

.1 QUALITY CONTROL DATA I,

151

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: December 7, 2006 Client : Connecticut Yankee Atomic Power Page 1 of 16 362 Injun Hollow Rd East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder: 176890 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Alpha Spec Batch 592107 QC1201238057 176896007 DUP Americium-241 U 0.105 U 0.0986 pCi/g 6 (0%- 100%) IXAI 12/03/06 09:01 Uncert: +/-0.153 +/-0.182 TPU: +/-0.154 +/-0.183 Curium-242 U 0.075 U -0.00937 pCi/g 257 (0%- 100%)

Uncert: +/-0.129 +/-0.0787 TPU: +/-0.130 +/-0.0788 Curium-243/244 U 0.0863 U 0.00564 pCi/g 175 (0%- 100%)

Uncert: +/-0.154 +/-0.153 TPU: +/-0.154 +/-0.153 QC1201238059 LCS Americium-241 13.5 12.7 pCi/g 94 (75%-125%)

Uncert: +/-1.32 TPU: +/-2.06 Curium-242 U 0.0185 pCi/g Uncert: +/-0.0736 TPU: +/-0.0736 Curium-243/244 11.7 11.1 pCi/g 95 (75%-125%)

Uncert: +/- 1.23 TPU: +/-1.84 QC1201238056 MB Americium-241 U -0.0952 pCi/g Uncert: +/-0.0629 TPU: +/-0.064 Curium-242 U -0.0674 pCi/g Uncert: +/-0.0467 TPU: +/-0.0475 U -0.173 pCi/g Curium-243/244 Uncert: +/-0.131 TPU: +/-0.133 QC1201238058 176896007 MS Americium-24 I 13.7 U 0.105 12.1 pCi/g 88 (75%-125%)

Uncert: +/-0.153 +/-1.19 TPU: +/-0.154 +/-1.87 Curium-242 U 0.075 U 0.0267 pCi/g Uncert: +/-0.129 +/-0.099 TPU: +/-0.130 +/-0.0991 Curium-243/244 11.9 U 0.0863 11.6 pCi/g 98 (75%-125%)

Uncert: +/-0.154 +/-1.17 TPU +/-0.154 +/-1.80 Batch 592108 QC1201238061 176896007 DUP Plutonium-238 U 0.0367 U 0.0113 pCi/g 106 (0% - 100%) IXAI 12/03/06 09:01 152

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 2 of 16 Parmname NOM Sample Qual OC Units RPD% REC% Range AnIst Date Time Rad Alpha Spec Batch 592108 Uncert: +/-0.103 +/-0.107 TPU: +/-0.103 +/-0.107 Plutonium-239/240 U 0.0268 U -0.0847 pCi/g 385 (0%- 100%)

Uncert: +/-0.071 +/-0.0525 TPU: +/-0.0711 +/-0.0535 QC1201238063 LCS Plutonium-238 U -0.034 pCi/g (75%-125%)

Uncert: +/-0.123 TPU: +/-0.123 Plutonium-239/240 12.0 10.9 pCi/g 91 (75%-125%)

Uncert: +/-1.16 TPU: +/-1.75 QC1201238060 MB Plutonium-238 U 0.0771 pCi/g Uncert: +/-0.165 TPU: +/-0.165 Plutonium-239/240 U 0.0681 pCi/g Uncert: +/-0.228 TPU: +/-0.228 QC1201238062 176896007 MS Plutonium-238 U 0.0367 U -0.0903 pCi/g (75%-125%)

Uncert: +/-0.103 +/-0.175 TPU: +/-0.103 +/-0.176 Plutonium-239/240 12.0 U 0.0268 11.2 pCi/g 93 (75%-125%)

Uncert: +/-0.071 +/-1.17 TPU: +/-0.0711 +/-1.78 Batch 592109 QC1201238065 176896007 DUP Plutonium-241 U 6.51 U 4.12 pCi/g 0 (0% - 100%) vIXAI 12/05/06 20:09 Uncert: +/-7.02 +/-7.74 TPU: +/-7.05 +/-7.75 QC1201238067 LCS Plutonium-241 139 136 pCi/g 98 (75%-125%) 12/05/06 20:42 Uncert: +/-11.8 TPU: +/-17.6 QC1201238064 MB Plutonium-241 U 3.78 pCi/g 12/05/06 19:53 Uncert: +/-6.72 TPU: +/-6.73 QC1201238066 176896007 MS Plutonium-241 141 U 6.51 139 pCi/g 99 (75%-125%) 12/05/06 20:26 Uncert: +/-7.02 +/-12.2 TPU: +/-7.05 +/-18.1 Rad Gamma Spec Batch 592142 QC1201238142 176890002 DUP Actinium-228 0.499 0.739 pCi/g 39 (0%- 100%) MJH1 12/04/06 07:00 Uncert: +/-0.133 +/-0.139

+/-0.139 153

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 3 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 592142 TPU: +/-0.133 Americium-241 u 0.0286 U 0.00936 pCi/g 101 (0%- 100%)

Uncert: +/-0.0593 +/-0.0223 TPU: +/-0.0593 +/-0.0223 Bismuth-212 0.400 0.367 pCi/g 8 (0%- 100%)

Uncert: +/-0.177 +/-0.223 TPU: +/-0.177 +/-0.223 Bismuth-214 0.425 0.515 pCi/g 19 (0% - 100%)

Uncert: +/-0.0754 +/-0.0798 TPU: +/-0.0754 +/-0.0798 Cesium- 134 U 0.0213 Ut 0.00 pCi/g 91 (0%- 100%)

Uncert: +/-0.0198 +/-0.0286 TPU: +/-0.0198 +/-0.0286 Cesium-137 0.0722 0.0527 pCi/g 31 (0% - 100%)

Uncert: +/-0.0297 +/-0.0252 TPU: +/-0.0297 +/-0.0252 Cobalt-60 U 0.0304 U 0.00911 pCi/g 108 (0% - 100%)

Uncert: +/-0.0183 +/-0.0209 TPU: +/-0.0183 +/-0.0209 Europium-152 U 0.00662 U -0.00857 pCi/g 1550 (0%- 100%)

Uncert: +/-0.0743 +/-0.0387 TPU: +/-0.0743 +/-0.0387 Europium- 154 U 0.00889 U -0.0259 pCi/g 409 (0%- 100%)

Uncert: +/-0.098 +/-0.0566 TPU: +/-0.098 +/-0.0566 Europium- 155 U 0.0169 U 0.0258 pCi/g 42 (0%- 100%)

Uncert: +/-0.0482 +/-0.0557 TPU: +/-0.0482 +/-0.0557 Lead-212 0.527 0.591 pCi/g 11 (0% - 20%)

Uncert: +/-0.0622 +/-0.0454 TPU: +/-0.0622 +/-0.0454 Lead-214 0.556 0.640 pCi/g 14 (0% - 20%)

Uncert: +/-0.0808 +/-0.0736 TPU: +/-0.0808 +/-0.0736 Manganese-54 U 0.00229 U 0.00242 pCi/g 5 (0%- 100%)

Uncert: +/-0.0177 +/-0.0176 TPU: +/-0.0177 +/-0.0176 Niobium-94 U -0.0108 U -0.00432 pCi/g 86 (0% - 100%)

Uncert: +/-0.0173 +/-0.0161 TPU: +/-0.0173 +/-0.0161 Potassium-40 11.4 10.1 pCi/g 12 (0% - 20%)

Uncert: +/-0.994 +/-0.786 TPU: +/-0.994 +/-0.786 Radium-226 0.425 0.515 pCi/g 19 (0%- 100%)

Uncert: +/-0.0754 +/-0.0798 TPU: +/-0.0754 +/-0.0798 Silver- 108m U 0.0032 U 0.0106 pCi/g 107 (0%- 100%)

Uncert: +/-0.0141 +/-0.0144 154

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 4 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 592142 TPU: +/-0.0141 +/-0.0144 Thallium-208 0.144 0.188 pCi/g 26 (0%- 100%)

Uncert: +/-0.0319 +/-0.0358 TPU: +/-0.0319 +/-0.0358 QC1201238143 LCS Actinium-228 U -0.0385 pCi/g 12/04/06 07:02 Uncert: +/-0.615 TPU: +/-0.615 Americium-241 23.4 24.4 pCi/g 104 (75%-125%)

Uncert: +/-0.541 TPU: +/-0.541 Bismuth-212 U -0.109 pCi/g Uncert: +/-0.957 TPU: +/-0.957 Bismuth-214 U -0.146 pCi/g Uncert: +/-0.217 TPU: +/-0.217 Cesium- 134 U -0.0676 pCi/g Uncert: +/-0.149 TPU: +/-0.149 Cesium- 137 9.52 10.4 pCi/g 109 (75%-125%)

Uncert: +/-0.503 TPU: +/-0.503 Cobalt-60 14.0 14.5 pCi/g 104 (75%-125%)

Uncert: +/-0.677 TPU: +/-0.677 Europium- 152 U -0.0484 pCi/g Uncert: +/-0.266 TPU: +/-0.266 Europium- 154 U 0.090 pCi/g Uncert: +/-0.250 TPU: +/-0.250 Europium- 155 U 0.144 pCi/g Uncert: +/-0.227 TPU: +/-0.227 Lead-212 U -0.0264 pCi/g Uncert: +/-0.146 TPU: +/-0.146 Lead-214 U 0.0333 pCi/g Uncert: +/-0.193 TPU: +/-0.193 Manganese-54 U 0.0139 pCi/g Uncert: +/-0.142 TPU: +/-0.142 Niobium-94 U -0.0307 pCi/g Uncert: +/-0.116 TPU: +/-0.116 Potassium-40 U 0.0841 pCi/g 155

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 5 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 592142 Uncert: +/-0.896 TPU: +/-0.896 Radium-226 U -0.146 pCi/g (75%-125%)

Uncert: +/-0.217 TPU: +/-0.217 Silver- 108m U 0.019 pCi/g Uncert: +/-0.109 TPU: +/-0.109 Thallium-208 U -0.0275 pCi/g Uncert: +/-0.125 TPU: +/-0.125 QC1201238141 MB Actinium-228 U 0.016 pCi/g 12/04/06 07:00 Uncert: +/-0.0236 TPU: +/-0.0236 Americium-241 U 0.00128 pCi/g Uncert: +/-0.0195 TPU: +/-0.0195 Bismuth-212 U 0.0245 pCi/g Uncert: +/-0.102 TPU: +/-0.102 Bismuth-214 U 0.0232 pCi/g Uncert: +/-0.0167 TPU: +/-0.0167 Cesium- 134 U -0.00374 pCi/g Uncert: +/-0.00763 TPU: +/-0.00763 Cesium- 137 U -0.00427 pCi/g Uncert: +/-0.00666 TPU: +/-0.00666 Cobalt-60 U 0.00632 pCi/g Uncert: +/-0.00816 TPU: +/-0.00816 Europium- 152 U -0.0022 pCi/g Uncert: +/-0.0183 TPU: +/-0.0183 Europium- 154 U -0.0122 pCi/g Uncert: +/-0.019 TPU: +/-0.019 Europium-155 U 0.00667 pCi/g Uncert: +/-0.0183 TPU: +/-0.0183 Lead-212 U 0.0162 pCi/g Uncert: +/-0.0249 TPU: +/-0.0249 Lead-214 U 0.00126 pCi/g Uncert: +/-0.0145 TPU: +/-0.0145 156

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 6 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Ran2e Anist Date Time Rad Gamma Spec Batch 592142 Manganese-54 U 0.00222 pCi/g Uncert: +/-0.00775 TPU: +/-0.00775 Niobium-94 U 0.00384 pCi/g Uncert: +/-0.00734 TPU: +/-0.00734 Potassium-40 U 0.158 pCi/g Uncert: +/-0.098 TPU: +/-0.098 Radium-226 U 0.0232 pCi/g Uncert: +/-0.0167 TPU: +/-0.0167 Silver-108m U 0.00867 pCi/g Uncert: +/-0.0121 TPU: +/-0.0121 Thallium-208 UI 0.00 pCi/g Uncert: +1-0.00876 TPU: +1-0.00876 Batch 592146 QC1201238150 176890021 DUP Actinium-228 0.653 0.772 pCi/g 17 (0%- 100%) MJHI 12/04/06 17:04 Uncert: +/-0.116 +/-0.226 TPU: +/-0.116 +/-0.226 Americium-241 U 0.0304 U 0.00742 pCi/g 122 (0%- 100%)

Uncert: +/-0.0962 +/-0.0441 TPU: +/-0.0962 +1-0.0441 Bismuth-212 0.310 0.528 pCi/g 52 (0%- 100%)

Uncert: +/-0.146 +/-0.284 TPU: +/-0.146 +/-0.284 Bismuth-214 0.460 0.648 pCi/g 34 (0%- 100%)

Uncert: +/-0.0714 +/-0.133 TPU: +/-0.0714 +/-0.133 Cesium-134 U 0.0224 U 0.0597 pCi/g 91 (0%- 100%)

Uncert: +/-0.0252 +/-0.0341 TPU: +/-0.0252 +/-0.0341 Cesium- 137 0.0818 0.141 pCi/g 53 (0%- 100%)

Uncert: +/-0.0346 +/-0.0502 TPU: +/-0.0346 +/-0.0502 Cobalt-60 U 0.0133 U 0.0349 pCi/g 89 (0%- 100%)

Uncert: +/-0.0189 +/-0.0362 TPU: +/-0.0189 +/-0.0362 Europium- 152 U -0.0333 U 0.0182 pCi/g 680 (0%- 100%)

Uncert: +/-0.0418 +/-0.0837 TPU: +/-0.0418 +/-0.0837 Europium- 154 U -0.00674 U 0.0349 pCi/g 296 (0%- 100%)

Uncert: +/-0.0547 +/-0.0934 TPU: +/-0.0547 +/-0.0934 Europium-155 U 0.0667 U -0.0559 pCi/g 2260 (0%- 100%)

157

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 7 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 592146 Uncert: +/-0.0453 +/-0.0576 TPU: +/-0.0453 +/-0.0576 Lead-212 0.546 0.600 pCi/g 9 (0% - 20%)

Uncert: +/-0.0463 +/-0.0819 TPU: +/-0.0463 +/-0.0819 Lead-214 0.514 0.534 pCi/g 4 (0%- 20%)

Uncert: +/-0.0687 +1-0.126 TPU: +/-0.0687 +/-0.126 Manganese-54 U -0.000315 U 0.0101 pCi/g 213 (0%- 100%)

Uncert: +/-0.0172 +/-0.0298 TPU: +/-0.0172 +/-0.0298 Niobium-94 u 0.00315 U 0.00311 pCi/g 1 (0%- 100%)

Uncert: +/-0.015 +/-0.0262 TPU: +/-0.015 +/-0.0262 Potassium-40 10.3 10.6 pCi/g 2 (0% - 20%)

Uncert: +/-0.751 +/-1.09 TPU: +/-0.751 +/- 1.09 Radium-226 0.460 0.648 pCi/g 34 (0%- 100%)

Uncert: +/-0.0714 +/-0.133 TPU: +/-0.0714 +/-0.133 Silver- 108m u 0.000752 U -0.00403 pCi/g 292 (0%- 100%)

Uncert: +/-0.0147 +/-0.0236 TPU: +/-0.0147 +/-0.0236 Thallium-208 0.195 0.260 pCi/g 28 (0%- 100%)

Uncert: +/-0.0382 +/-0.0594 TPU: +/-0.0382 +/-0.0594 QC1201238151 LCS Actinium-228 U -0.488 pCi/g 12/04/06 15:26 Uncert: +/-0.552 TPU: +/-0.552 Americium-241 23.4 25.2 pCi/g 108 (75%-125%)

Uncert: +/-1.39 TPU: +/-1.39 Bismuth-212 U 0.520 pCi/g Uncert: +/-0.883 TPU: +/-0.883 Bismuth-214 U 0.0288 pCi/g Uncert: +/-0.206 TPU: +/-0.206 Cesium-134 U -0.0365 pCi/g Uncert: +/-0.134 TPU: +/-0.134 Cesium- 137 9.52 9.91 pCi/g 104 (75%-125%)

Uncert: +/-0.472 TPU: +/-0.472 Cobalt-60 14.0 14.8 pCi/g 106 (75%-125%)

Uncert: +/-0.658 TPU: +/-0.658 158

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 8 of 16 Parnmame NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 592146 Europium- 152 0.194 pCi/g Uncert: +/-0.277 TPU: +/-0.277 Europium- 154 -0.107 pCi/g Uncert: +/-0.271 TPU: +/-0.271 Europium- 155 -0.113 pCi/g Uncert: +/-0.260 TPU: +/-0.260 Lead-212 0.107 pCi/g Uncert: +/-0.141 TPU: +/-0.141 Lead-214 0.0797 pCi/g Uncert: +/-0.204 TPU: +/-0.204 Manganese-54 -0.0653 pCi/g Uncert: +/-0.130 TPU: +/-0.130 Niobium-94 -0.0949 pCi/g Uncert: +/-0.101 TPU: +/-0.101 Potassium-40 -0.204 pCi/g Uncert: +/-0.917 TPU: +/-0.917 Radium-226 0.0288 pCi/g (75%-125%)

Uncert: +/-0.206 TPU: +/-0.206 Silver- 108m 0.0478 pCi/g Uncert: +/-0.104 TPU: +/-0.104 Thallium-208 -0.0406 pCi/g Uncert: +/-0.109 TPU: +/-0.109 QC1201238149 MB Actinium-228 U 0.0643 pCi/g 12/04/06 17:42 Uncert: +/-0.0659 TPU: +/-0.0659 Americium-241 U -0.0189 pCi/g Uncert: +/-0.0147 TPU: +/-0.0147 Bismuth-212 U 0.0293 pCi/g Uncert: +/-0.112 TPU: +/-0.112 Bismuth-214 U 0.0401 pCi/g Uncert: +/-0.0335 TPU: +/-0.0335 Cesium- 134 U 0.00113 pCi/g Uncert: +/-0.0142 159

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 9 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 592146 TPU: +/-0.0142 Cesium- 137 U 0.00699 pCi/g Uncert: +/-0.0149 TPU: +/-0.0149 Cobalt-60 U -0.00231 pCi/g Uncert: +/-0.0144 TPU: +/-0.0144 Europium- 152 U 0.0164 pCi/g Uncert: +/-0.0372 TPU: +/-0.0372 Europium- 154 U 0.0218 pCi/g Uncert: +/-0.0406 TPU: +/-0.0406 Europium- 155 U 0.0163 pCi/g Uncert: +/-0.0308 TPU: +/-0.0308 Lead-212 U 0.0023 pCi/g Uncert: +/-0.0278 TPU: +/-0.0278 Lead-214 U 0.00765 pCi/g Uncert: +/-0.0485 TPU: +/-0.0485 Manganese-54 U -0.00235 pCi/g Uncert: +/-0.0133 TPU: +/-0.0133 Niobium-94 U -0.00472 pCi/g Uncert: +1-0.0162 TPU: +/-0.0162 Potassium-40 U 0.0987 pCi/g Uncert: +/-0.116 TPU: +/-0.116 Radium-226 U 0.0401 pCi/g Uncert: +/-0.0335 TPU: +/-0.0335 Silver-108m U -0.00202 pCi/g Uncert: +/-0.014 TPU: +/-0.014 Thallium-208 U 0.00785 pCi/g Uncert: +/-0.0225 TPU: +/-0.0225 Batch 592150 QC1201238153 176890037 DUP Actinium-228 0.981 0.900 pCi/g 9 (0%- 100%) MJHI 12/05/06 09:14 Uncert: +/-0.222 +/-0.158 TPU: +/-0.222 +/-0.158 Americium-241 U 0.0919 U -0.197 pCi/g 551* (0%- 100%)

Uncert: +/-0.0882 +/-0.104 TPU: +/-0.0882 +/-0.104 160

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 10of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 592150 Bismuth-212 0.446 0.694 pCi/g 44 (0%- 100%)

Uncert: +/-0.261 +/-0.257 TPU: +/-0.261 +/-0.257 Bismuth-214 0.816 0.765 pCi/g 6 (0%- 100%)

Uncert: +/-0.141 +/-0.0737 TPU: +/-0.141 +/-0.0737 Cesium- 134 U 0.0437 UI 0.00 pCi/g 16 (0%- 100%)

Uncert: +/-0.0421 +/-0.0458 TPU: +/-0.0421 +/-0.0458 Cesium- 137 U 0.0263 0.0438 pCi/g 50 (0% - 100%)

Uncert: +/-0.0235 +/-0.0237 TPU: +/-0.0235 +/-0.0237 Cobalt-60 U 0.00625 U 0.0107 pCi/g 52 (0% - 100%)

Uncert: +/-0.0252 +/-0.0203 TPU: +/-0.0252 +/-0.0203 Europium- 152 U -0.0249 U -0.0473 pCi/g 62 (0%- 100%)

Uncert: +/-0.0678 +/-0.054 TPU: +/-0.0678 +/-0.054 Europium- 154 U 0.00552 U -0.0225 pCi/g 330 (0%- 100%)

Uncert: +/-0.0674 +/-0.0625 TPU: +/-0.0674 +/-0.0625 Europium- 155 U 0.0596 U 0.0273 pCi/g 75 (0%- 100%)

Uncert: +/-0.0663 +/-0.0675 TPU: +/-0.0663 +/-0.0675 Lead-212 0.887 0.821 pCi/g 8 (0% - 20%)

Uncert: +/-0.0951 +/-0.0587 TPU: +/-0.0951 +/-0.0587 Lead-214 0.971 0.952 pCi/g 2 (0% - 20%)

Uncert: +/-0.122 +/-0.0886 TPU: +/-0.122 +/-0.0886 Manganese-54 U 0.0219 U 0.0276 pCi/g 23 (0%- 100%)

Uncert: +/-0.0248 +/-0.0202 TPU: +/-0.0248 +/-0.0202 Niobium-94 U 0.0299 U -0.00933 pCi/g 382 (0%- 100%)

Uncert: +/-0.0216 +/-0.0186 TPU: +/-0.0216 +/-0.0186 Potassium-40 13.5 13.1 pCi/g 3 (0% - 20%)

Uncert: +/-1.25 +/-0.863 TPU: +/-1.25 +/-0.863 Radium-226 0.816 0.765 pCi/g 6 (0% - 100%)

Uncert: +/-0.141 +/-0.0737 TPU: +/-0.141 +/-0.0737 Silver- 108m U -0.00544 U -0.00579 pCi/g 6 (0% - 100%)

Uncert: +/-0.0204 +/-0.0176 TPU: +/-0.0204 +/-0.0176 Thallium-208 0.289 0.261 pCi/g 10 (0%- 100%)

Uncert: +/-0.0467 +/-0.0402 TPU: +/-0.0467 +/-0.0402 161

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 11 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 592150 QC1201238154 LCS Actinium-228 U -0.397 pCi/g 12/04/06 16:30 Uncert: +/-0.536 TPU: +/-0.536 Americium-241 23.4 24.9 pCi/g 107 (75%-125%)

Uncert: +/-1.19 TPU: +/-1.19 Bismuth-212 U -0.483 pCi/g Uncert: +/-1.11 TPU: +/-1.11 Bismuth-214 U 0.0809 pCi/g Uncert: +/-0.196 TPU: +/-0.196 Cesium- 134 U 0.0595 pCi/g Uncert: +/-0.138 TPU: +/-0.138 Cesium- 137 9.52 9.66 pCi/g 102 (75%-125%)

Uncert: +/-0.457 TPU: +/-0.457 Cobalt-60 14.0 14.9 pCi/g 107 (75%-125%)

Uncert: +/-0.660 TPU: +/-0.660 Europium- 152 U -0.0234 pCi/g Uncert: +/-0.280 TPU: +/-0.280 Europium- 154 U -0.221 pCi/g Uncert: +/-0.266 TPU: +/-0.266 Europium- 155 U -0.0817 pCi/g Uncert: +/-0.258 TPU: +/-0.258 Lead-212 U 0.0685 pCi/g Uncert: +/-0.143 TPU: +/-0.143 Lead-214 U 0.0824 pCi/g Uncert: +/-0.191 TPU: +/-0.191 Mangatnese-54 U -0.124 pCi/g Uncert: +/-0.131 TPU: +/-0.131 Niobium-94 U -0.0438 pCi/g Uncert: +/-0.102 TPU: +/-0.102 Potassium-40 U 0.755 pCi/g Uncert: +/-0.929 TPU: +/-0.929 Radiumn-226 U 0.0809 pCi/g (75%-125%)

Uncert: +/-0.196 TPU: +/-0.196 162

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 12 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 592150 Silver- 108m U -0.00842 pCi/g Uncert: +/-0.107 TPU: +/-0.107 Thallium-208 U -0.0326 pCi/g Uncert: +/-0.108 TPU: +/-0.108 QC1201238152 MR Actinium-228 U 0.0113 pCi/g 12/05/06 19:51 Uncert: +/-0.0435 TPU: +/-0.0435 Americium-241 U -0.0296 pCi/g Uncert: +/-0.0177 TPU: +/-0.0177 Bismuth-212 U 0.015 pCi/g Uncert: +/-0.0419 TPU: +/-0.0419 Bismuth-214 U 0.0116 pCi/g Uncert: +/-0.0236 TPU: +/-0.0236 Cesium- 134 U -0.000375 pCi/g Uncert: +/-0.00557 TPU: +/-0.00557 Cesium- 137 U -0.000115 pCi/g Uncert: +/-0.00543 TPU: +/-0.00543 Cobalt-60 U -0.00342 pCi/g Uncert: +/-0.0055 TPU: +1-0.0055 Europium- 152 U -0.00903 pCi/g Uncert: +/-0.0166 TPU: +/-0.0166 Europium- 154 U -0.00306 pCi/g Uncert: +/-0.0177 TPU: +/-0.0177 Europium-155 U -0.00351 pCi/g Uncert: +/-0.0153 TPU: +/-0.0153 Lead-212 U 0.00851 pCi/g Uncert: +/-0.0156 TPU: +/-0.0156 I ead-214 U 0.00894 pCi/g Uncert: +/-0.0169 TPU: +/-0.0169 Manganese-54 U -0.000214 pCi/g Uncert: +/-0.00518 TPU: +/-0.00518 Niobium-94 U -0.00293 pCi/g Uncert: +/-0.00533 163

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 13 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 592150 TPU: +/-0.00533 Potassiurn-40 UI 0.00 pCi/g Uncert: +/-0.0645 TPU: +/-0.0645 Radium-226 U 0.0116 pCi/g Uncert: +/-0.0236 TPU: +/-0.0236 Silver- 108m U -0.000358 pCi/g Uncert: +/-0.00455 TPU: +/-0.00455 Thallium-208 U 0.00324 pci/g Uncert: +/-0.0104 TPU: +/-0.0104 Rad Gas Flow Batch 592186 QC1201238232 176896007 DUP Strontium-90 0.766 0.315 pCi/g 84* (0% - 20%) KSD1 12/07/06 12:19 Uncert: +/-0.116 +/-0.0715 TPU: +/-0.118 +/-0.0719 QC1201238234 LCS Strontium-90 4390 4740 pCi/g 108 (75%-125%) 12/07/06 12:24 Uncert: +/-5.18 TPU: +/-108 QC1201238231 MB Strontium-90 U 0.00521 pCi/g 12/07/06 12:18 Uncert: +/-0.017 TPU: +/-0.017 QC1201238233 176896007 MS Strontium-90 4390 0.766 4830 pCi/g 110 (75%-125%) 12/07/06 12:23 Uncert: +/-0.116 +/-5.59 TPU: +/-0.118 +/-120 Rad Liquid Scintillation Batch 592304 QC1201238527 176518004 DUP Iron-55 U -16.5 U -9.15 pCi/g 0 (0% - 100%) MXPI 12/02/06 19:38 Uncert: +/-39.7 +/-36.9 TPU: +/-39.7 +/-36.9 QC1201238529 LCS Iron-55 797 803 pCi/g 101 (75%-125%) 12/02/06 20:11 Uncert: +/-60.4 TPU: +/-107 QC1201238526 MB Iron-55 U -10.8 pCi/g 12/02/06 19:22 Uncert: +/-29.0 TPU: +/-29.0 QC1201238528 176518004 MS Iron-55 806 U -16.5 789 pCi/g 98 (75%-125%) 12/02/06 19:54 Uncert: +/-39.7 +/-72.2

+/-126 164

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 14 of 16 Parmname NOM Sample Qual QC Units RPD% REC % Range Anlst Date Time Rad Liquid Scintillation Batch 592304 TPU: +/-39.7 Batch 592310 QC1201238547 176896007 DUP Nickel-63 U -2.44 U 4.04 pCi/g 0 (0% - 100%) MXP1 12/04/06 21:37 Uncert: +/-12.1 +/-12.8 TPU: +/-12.1 +/-12.8 QC1201238549 LCS Nickel-63 513 503 pCi/g 98 (75%-125%) 12/04/06 22:10 Uncert: +/-27.8 TPU: +/-32.8 QC1201238546 MB Nickel-63 U -3.04 pCi/g 12/04/06 21:20 Uncert: +/-10.4 TPU: +/-10.4 QC1201238548 176896007 MS Nickel-63 513 U -2.44 595 pCi/g 116 (75%-125%) 12/04/06 21:53 Uncert: +/-12.1 +/-32.5 TPU: +/-12.1 +/-38.5 Batch 592312 QC1201238555 176896007 DUP Technetium-99 U 0.194 U 0.175 pCi/g 11 (0% - 100%) KXRI 12/06/06 19:28 Uncert: +/-0.161 +/-0.153 TPU: +/-0.162 +/-0.153 QC1201238557 LCS Technetium-99 12.9 12.7 pCi/g 99 (75%-125%) 12/06/06 20:32 Uncert: +/-0.375 TPU: +/-0.471 QC1201238554 MB Technetium-99 0.283 pCi/g 12/06/06 18:57 Uncert: +/-0.148 TPU: +/-0.148 QC1201238556 176896007 MS Technetium-99 12.9 U 0.194 12.6 pCi/g 98 (75%-125%) 12/06/06 20:00 Uncert: +/-0.161 +/-0.388 TPU: +/-0.162 +/-0.480 Batch 592313 QC1201238559 176896007 DUP Carbon-14 U -0.0179 U -0.0249 pCi/g 0 (0% - 100%) AXD2 12/01/06 22:47 Uncert: +/-0.0898 +/-0.0889 TPU: +/-0.0898 +/-0.0889 QC1201238561 LCS Carbon- 14 6.69 7.10 pCi/g 106 (75%-125%) 12/02/06 00:53 Uncert: +/-0.201 TPU: +/-0.229 QC1201238558 MB Carbon- 14 U 0.000718 pCi/g 12/01/06 21:43 Uncert: +/-0.0906 TPU: +/-0.0906 QC1201238560 176896007 MS 165

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 15 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Liquid Scintillation Batch 592313 Carbon-14 6.86 U -0.0179 6.91 pCi/g 101 (75%-125%)

Uncert: +/-0.0898 +/-0.202 TPU: +/-0.0898 +/-0.228 Batch 593064 QC1201240326 176890008 DUP Tritium U -1.0 U -1.35 pCi/g 0 (0% - 100%) DFA1 12/06/06 09:52 Uncert: +/-1.29 +/-1.29 TPU: +/-1.29 +/-1.29 QC1201240328 LCS Tritium 15.2 15.3 pCi/g 100 (75%-125%) 12/06/06 14:05 Uncert: +/-0.929 TPU: +/-0.965 QC1201240325 MB Tritium U -0.759 pCi/g 12/06/06 07:45 Uncert: +/-0.578 TPU: +/-0.578 QC1201240327 176890008 MS Tritium 19.8 U -1.0 16.3 pCi/g 83 (75%-125%) 12/06/06 11:59 Uncert: +/-1.29 +/-2.05 TPU: +/-1.29 +/-2.07 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria

  • Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product 13 Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded 166

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 176890 Page 16 of 16 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

167

General Narrative 1

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 177540 SDG: MSR#06-1549 December 14,2006 Laboratory Identification:

General Engineering Laboratories, LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at General Engineering Laboratories, LLC, Charleston, South Carolina on November 10, 2006 and November 30, 2006 for analysis. Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures.

All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Sample Identification Description 177540001 9522-0001-OOIF 177540002 9522-0001-002F 177540003 9522-0001-003F 177540004 9522-0001-004F 177540005 9522-0001-005F 177540006 9522-0001-006F 177540007 9522-0001-009F 177540008 9522-0001-01 OF 177540009 9522-0001-01 IF 177540010 9522-0001-012F 177540011 9522-0001-013F 177540012 9522-0001-015F 177540013 9522-0001-016F 177540014 9522-0001-021-I 177540015 9522-0001-024-1 177540016 9522-0002-002F 177540017 9522-0002-003F 177540018 9522-0002-005F 177540019 9522-0002-007F 177540020 9522-0002-008F 177540021 9522-0002-01 OF 177540022 9522-0002-011 F 177540023 9522-0002-012F 177540024 9522-0002-013F 177540025 9522-0002-014F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417 *2040 Savage Road (29407)

Phone (843) 556-8171 , FaxZ43) 766-1178 www.gel.com

177540026 9522-0002-016F 177540027 9522-0003-001F 177540028 9522-0003-002F 177540029 9522-0003-003F 177540030 9522-0003-004F 177540031 9522-0003-005F 177540032 9522-0003-007F 177540033 9522-0003-008F 177540034 9522-0003-009F 177540035 9522-0003-OIOF 177540036 9522-0003-01IF 177540037 9522-0003-012F 177540038 9522-0003-013F 177540039 9522-0003-014F 177540040 9522-0003-015F 177540041 9522-0004-001F 177540042 9522-0004-002F 177540043 9522-0004-003F 177540045 9522-0004-005F 177540046 9522-0004-006F 177540047 9522-0004-008F 177540048 9522-0004-009F 177540049 9522-0004-01 OF 177540050 9522-0004-01 IF 177540051 9522-0004-012F 177540052 9522-0004-013F 177540053 9522-0004-014F 177540054 9522-0004-015F 177540055 9522-0004-016F Items of Note The above samples were relogged at the request of Arthur Hammond on 12/11/06. See attached emails.

Case Narrative Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL)

Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request Fifty-four soil samples were analyzed for Strontium-90.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417

  • 2040 Savage Road (29407)

Phone (843) 556-8171 - Fax*43) 766-1178 www.gel.com

List of current GEL Certifications as of 14 December 2006 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01151 CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FL/NELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SC012 Michigan 9903 Nevada SCI2 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R- 158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP TI04704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C1641 4

Chain of Custody and Supporting Documentation 5

Health Physics, Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major Chain of Custody Form N.20-06 Connecticut Yankee Atomic Power Company No. 2006-00666 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use-Onily Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Aoz-&o- - -- o, Analytical Lab (Name, City, State) " - -"4'5 o General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 I

843 556 8171. Attn. Cheryl Jones Priority: E-30 D. [] 14 D. ] 7 D. I 3 D. C a Container " ' L Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9522-0001-012F 11/09/06 0808 TS G BP X 9522-0001-015F 11/09/06 0815 TS G BP X 9522-0001-002F 11/09/06 0954 TS G BP X I/

9522-0001-OOIF 11/09/06 0955 TS G BP X 9522-0001-003F 11/09/06 0958 TS G BP X

,/

9522-0001-OIOF 11/09/06 1052 TS G BP X 9522-0001-014F 11/09/06 1054 TS G BP X L 9522-0001-009F 11/09/06 1057 TS G BP X

'9522-0001-009FS 11/09/06 1057 TS G BP X

./1 9522-0001-008F 11/09/06 1311 TS G BP X 9522-0001-OIIF 11/09/06 1312 TS G BP X 1 _- - A NOTES: PO 4: 002332 MSR #: 06-U14F/-' SSWP# NA Z LTPQA E] RadwasteQA [] Non QA Samples Shipped Via: Internal .Container

[ Fed Ex Temp.: _ Deg.

Ups U C Fl Hand Custody Sealed?

Ytl NO

1) Relinquished By Date/Time 2) ed By Date/Time Custody Seal EI Other Intact?
3) Relinquished By Date/Time 4) Received By Date/Time Y N0 Bill of Lading#

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Chain of Custody Form N.20-06 Connecticut Yankee Atomic Power Company No. 2006-00667 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: [130 D. [] 14 D. [ 7 D. [13 D. 1 .

Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code I¢ 9522-0001-013F 11/09/06 1337 TS G BP X _._..

9522-0001-005F 11/09/06 1358 TS G BP X -

V 9522-0001-006F 1 1/09/06 1400 TS G BP X 9522-0001-004F 11/09/06 1405 TS G BP X NOTES: PO #: 002332 MSR #: 06-1~8V SSWP#NA E LTP QA [] Radwaste QA D Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: __ Deg, F-] ups C Hand H3 Custody Sealed?

YD NO

1) Relinquished By Date/Time /* Ofived By Custody Seal gig Date/Time

[1 Other Intact?

3) Relinquished By Date/Time 4) Received By Date/Time YOl NO]

Bill of Lading #

Health Physics Procedure GPP-GGGR-R5104-003 -Attach ment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00671 362 InJun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested I Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones cc' Priority: [] 30 D, E] 14 D. Z 7 D. El 3 D.

Sample Container Size-

~4(.J_ &A(!'

Sample Designation Date Time Media Type &Type Cornmcnt, Preservation Code Code Code 9522-0001-016F 11/15/06 - S TS G BP-NOTES: PO #: 002332 MSR #: 06-13-1" SSWP# NA Z LTP QA [] Radwaste QA El Non QA Samples Shipped Via: Internal Container 0 Fed Ex Temp.: - Deg.

[1 ups C El Hand Custody Sealed?

Yf N :I.-

1) Relinquished By Date/Time 2) Re i ed By Date/Time Custody Seal El Other Intact?
3) Relinquished By Date/Time 4) Received By Date/Time YL[ NL' Bill of Lading #

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Chain of Custody Form N.20-07 Connecticut Yankee Atomic Power Company No. 2006-00677 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2 2 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones Vý Priority: E130 D. E1 14 D. 0 7 D. 3 D. C a Sample Size-Sample Designation Date Time Media Type &Type nt, Preservation Lab Sample ID Code Code Code 9522-0001-017-I 11/16/06 0716 TS G BP X 9522-0001-018-I 11/16/06 0717 TS G BP X 9522-0001-019-I 11/16/06 0718 TS G BP X 9522-0001-020-1 11/16/06 0719 TS G BP X 9522-0001-021-1 11/16/06 1335 TS G BP X 9522-0001-022-I 11/16/06 1340 TS G BP X 9522-0001-023-I 11/16/06 1345 TS G BP X NOTES: PO #: 002332 MSR #: 06- Samples Shipped Via: Internal' Container 15,06" SSWP# NA Z LTP QA [] Radwaste QA E] Non QA

[ Fed Ex Temp.: - Deg.

EUPS C E] Hand Custody Sealed?

Y N

1) Relinquished By Date/Time 2 c ed By - Date/Time Custody, Seal

[] Other Intact?

3) Relinquished By Date/Time 4) Received By Date/Time Y N Bill of Lading #

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form N.20-08 Connecticut Yankee Atomic Power Company No. 2006-00684 362 InJun Hollow Road, East Hampton, CT 06424 860-267-2556 1.. - ., -

Project Name: Haddam Neck Decommissioning Analyses Requested Lab use unly Contact Name & Phone: I Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones 0, Cr' Priority: E!024D.- 14 D. 0 7 D. ED 3 D.1

(-ý Cc c6 9 (4-- ýf Container Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Code Code Code 9522-0001-024-1 11/21/06 14 TS G BP X _____ ____ ____________

NOTES: PO #: 002332 MSR #: 06-,I-W SSWP# NA Z LTP QA LI Radwaste QA L] Non QA Samples Shipped Via: Internal Container i5 66 [ Fed Ex Temp.: - Deg.

LI ups C LI Hand Custody Sealed?

YID N f

1) Relinquished By Date/Time 2 ved By Date/Time Custody Seal It0 o - Co El Other Intact?
3) Relinquished By Date/Time 4) Received By Date/Time Y[] N D Bill of Lading #

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O01 Figure 1. Samplc Check-M List Date/Thime Rcceived: ~C- X.,I C3 t1 SDG#: (t.A$ Ot.,-- -O 3 .1p"-k . -C(-

Work Order Number: t--14l CS. , qC Shipping Container ID: - ee C CIV , f Cutody I oClj'AU

]. Custody Seals on shipping container intact'? Yes )(No []

2. Custody Seals dated and signed'? Yes,, No [3
3. C hain-oF-Custody record present? Yes 0[
4. Cooler lernperature -* -

,ý*.)_5ý1 -e" I

5. Vermiculite/packing materials is: Wet [] Dry X 6- Ninber of samples in shipping container:
7. Samtolc holdini, times exceeded'?

Yes [j No XK

8. Samples have:

_ tape __--hazard labels custody seals _ appropriate sample labels

9. Samples arc:

V il good condition .... leaking broken have air bubbles M0. Were any anomalies identified in sample receipt'? Yes X"No

1. Description of anomalies (include sample numbers): nClD '_*-t r-, -e Sample Ctuslodian/Laboratory  : .Q L O . ~

DaeBy ~

Telephoned to: On _________By___________

Page 45 of 56 11

-fLj mrt SAMPLE RECEIPT & REVIEW FORM

'S N-PM a" ell

~Client: t fLy SDG/ARCOCJWork Order: - ~e p g~

Dlate Received:- 1I PM(A) Review (ensrIon-oI it ved pr1w Iae Received By:

Sample Receipt Criteria Z Comments/Qualifiers (Required for Non-Conformgdn Items) 7 Shipping containers received intact Circle Applicable: ils broken daMed container Ilnking container t(deib) and scaled? e Samples requiring cold Circle Coolant I ice bass blue ice dry ice

  • owi " dcribe) 2 preservation within (4 +/- 2 C)?

Record preservation method. -____._.,__________

Chain of custody documents included with shipment? _

4 Sample containers intact and irele Applicable: seals broken damaged contincr Icaking coaiau-r sealed? _T Samples requiring chemical SWapIe 1D'. contain- affected and observed pH:

reservation at proper p14 ?,,_ _ _'__ _

6 VOA vials free of headspace Sample ID's and co.ine affecutd:

(defined as < 6mm bubble)? _,

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory) "_ .

__/_ ......... __ _.. ... .

Samples received within holding lId's and teats affected:

time?

~Sample I1's on COC match ID's SuM1ID'adcontiners affected:

on bottles? I Date & time on COC match date Sample ID's affiectd:

& time on bottles? _/__

Number of containers received / s I'S affe.e:

match number indicated on COC? V.1 COC form is properly signed in l / ,5 relinquished/received sections? _ _ _ _ _ __ _ _ _ _ __5_ _ _

Air Bill ,Tracking #'s, &

Additional Comments 1

IcT O00-u q t ý0 q.Q -)0" / 7U9a

?Ta qoq~n

-? 3 j.(7 HaadIfraio0*.

Suspected RSO PAD Rc.ip- *, i.

  • If > x2 area background is observed on samples identified *non-ec Ha I regulated/non-radioactive". contact the Radiation Safety grupfor funhais OKa investigation.

A Radiological Classification? Maximum Counts Observ': / 7" SPCB Regulated?'

lUpped as VU0'1 Hazardous rd Class Shipped:

Material? If yes, contact Waste Manager or ESH Manager.

D eguate- asa oreiSl 01 I PM (or PMA) review of Hazard classification Date:ials Y

12

0 SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM 0',J V7

,.:, ...oo . -. /2*

-~o~Lc A

or'd q Y

- oo rI

.. ~- Ooe *

,,.

... - Co0 2c;,.Lf 13

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form N.20-04 Connecticut Yankee Atomic Power Company No. 2006-00647 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab, Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 J <

843 556 8171. Attn. Cheryl Jones U)

Priority: [ 30D. E] 14 D. E 7 D. - 3 D.

____ ____

____ ___ ____

________ ____ ___Container

-

Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9522-0002-OOIF 10/30/06 0813 TS G BP X 9522-0002-002F 10/30/06 0757 TS G BP X 9522-0002-003F 10/30/06 0817 TS G BP X 9522-0002-004F 10/30/06 0741 TS G BP X __.........

9522-0002-005F 10/30/06 1013 TS G BP X 9522-0002-006F 10/30/06 1020 TS G B3P X 9522-0002-007F 10/30/06 0945 TS G BP X 9522-0002-007FS 10/30/06 0945 TS G BP X 9522-0002-008F 10/30/06 1031 TS G BP X ....

9522-0002-009F 10/30/06 1035 TS G BP X 9522-0002-Ol1F 10/30/06 '1051 TS G BP x ......

NOTES: PO #: 002332 MSR #: 0644*r1A0 SSWP# NA Z LTP QA E] Radwaste QA El Non QA Samples Shipped Via: Internal Container Temp.: j3 Deg.

,qi 1 D [ Fed Ex El urs C ElHand Custody Sealed?

YV' NO

1) Reli q ed Date/Time 2) Received By Date/Time Custody Seal El Other 8327 Intact?
3) R9linquished By Date/Time 4) Received By Date/Time YV' NO Bill of Lading#

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00648 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2 2040 Savage Road. Charleston SC. 29407 <

843 556 8171. Attn. Cheryl Jones c Priority: E) 30D. [ 14 D. 0 7 D. [ 3 D. Container *****i~[

Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9522-0002-013F 10/30/06 1100 TS G BP X

! 95?-,*,.--oHF /0)/b40 J.* 7'; *- __,.__ ' _______."__ ..

9rJx-o%*2-oIGP JQ, /6L 122- TY g Pb ___.

01ý P~ Joh;bbl 13'c Tf & P~ __ - -__________

___________________- ji ý jldp.1ý0 &s Cr 9 .L. -_ _ _ _ __ _ _ _

NOTES: PO #: 002332 MSR #: 06-4-t SSWP4 NA 0 LTP QA [I Radwaste QA [] Non QA Samples Shipped Via: Internal Container

' il if [ Fed Ex Temp.: )-7 Deg.

C El Hand Custody Sealed?

YL NO

1) Relin qui dBy9 ,6 Date/Time 2) Received By Date/Time Custody Seal E3 Other Intact?
3) R inquished By Date/Time 4) Received By Date/Time 7i0f Ladin9#b$AV yIL'N 0 Bill of Lading #

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sampi ICheck-in List Date/Time Received': ) ) 4O" .L 0

SDG#: 560 jq Work Order Number:- 0 (75 175fq0tc Shipping Cdntainer ID: . C 3, 8c4, Chain of Custody t I. Custody Seals oni shipping container intact?.. Yes *4 No []

2. Custody Seals dated and signed? Yes* j No [.
3. Chain-of-Custo.y record present? Yes [V.No I ]
4. Cooler temperature . 7 \
5. Vermiculite/packing materials is: Wet [ ] Dry I. ] A 1Ž 6.' Number of samples in shipping container: ]  ;
7. Sample holding times exceeded? Yes [ No

.8. Samples have-'

tape-hazard labels

-custody seals -appropriate sample labels

9. Samples are:

'-:!*good condition . leaking broken -have air bubbles

10. Were any anomalies identified in sample receipt? Yes [ I No [L"
11. * .Description of anomalies.(include sample numbers): __"_"_-.

Sample Custodian/Laboratory: - t Date:.. 1/* -(No Telephoned to: O._ By y

16

a SAMPLE RECEIPT & REVIEW FORM r

PM use only Client: CCXYieC,4" A- V/Q6 ,tCOf SDG/ARCOC/Work Order: n -t ). 115-90&

Date Received:

B" - PM(A) Review (ensure non-conf" g are resolved prior to signing):

-Received By:

Sample Receipt Criteria

  • z z Comments/Qualifiers (Required for Non-Conforming Items) damaged container leaking container other (describe)

Cirle Applicable: seals broken 1 Shipping containers received intact and sealed? I Samples requiring cold Circle Coolant # ice bags blue ice dry ice none other describe) 2 preservation within (4 +1-  ?

Record preservation method. -

3 Chain of custody documents included with shipment?

4 Sample containers intact and Circle Applicable: seals broken damaged container leaking container other (describe) sealed? ll__

5 Samples requiring chemical Sample ID's, containers affected and observed pH:

  • reservation at proper pH?

VOA vials free of headspace Sam ID's and containers affected:

6 (defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to IVOA laboratory) 8 Samples received within holding Id's and tests affected:

time?

9 Sample ID's on COC match ID's Sample ID's and containers a7led

--on bottles? **.

Date & time on COC match date Sample ID's affected:

10 &time on bottles?

11 Number of containers received Sample ID's affected:

match number indicated on COC?

12 COC form is properly signed in 1 irelinquished/received sections?

14 jAir Bill ,Tracking i#'s, &

Additional Comments RORAD Re1ceipt #_________________

Hzad Information

  • Suspectedflatard Susectd IforatinS =.- 0 .. *If > x2 area background is observed on, samples identified as: ."non-regulated/non-radioactive't, contactWthe Radiati Safety C49 investigation.

C~a~sfk~ntoti?-1 - MaxienUni Counts Observed*:(1 i"o groupeor:*

fornager.e PUB ReglaCed? ments:

7hirp5Med as DO- Haardgous 77 ateralIf ontat WsteHazard ys, Class Shipped:

PM (or ger M)ESH Manager.

r PM (or P-MA) review of Hazard classification: Wntials Date:

()

17

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00655 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 T 114(ocý 843 556 8171. Attn. Cheryl Jones c Priority: Rl 30 D. [] 14 D. M 7 D. [] 3 D. Container C *e" 1 1 0 1 .. V4!;a#.-

W FSS ALL V-sAU-Samplc Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code

- P I 3/-, D)sy TS G BP _

  • j l-.,J.,

)p oiig I3;/*,. 1TS G BP .,_

uo't~i I7 TS G BP

°* )-4*-.ti- i iHi,. I3,) ' /X- -,

qi*'))-,. :-*-o:L.,F u IA'i.LIL.,. 7, G 41 -A 90 )

J/L

- .. 5 - t .':

F F 7~

i f_._

/ !3/

_ _ T )._ _ _

__

_ _ _ _ _

q c 1, cý, jF ~

G2}. 17IL V u I L. . .. . i L L IV.. S. _ _ _ _ _ _ _

Wt.;1 NOTES: PO#: 002332 MSR #: 06-P,&$  !-."SSWP# NA Z LTP QA [] Radwaste QA E] Non QA Samples Shipped Via: Internal Container tq5q Z Fed Ex Temp.: 0!Deg.

n UPS C E] Hand Cust d Sealed?

Ys N1

1) R in hed Date/Time 2) Received By Date/Time Custody Seal nl Other Intact?

3)'ielinquished By Date/Time 4) Received By Date/Time -7?*S- W1r-/ o25r Y;f NO Bill of Lading #

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major Chain of Custody Form N.20-05 Connecticut Yankee Atomic Power Company No. 2006-00656 362 Injun Hollow Road, East Hampton. CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 <

843 556 8171. Attn. Cheryl Jones Priority: [] 30 D. [] 14 D. Z 7 D. [13 D. i c-5 - AFL Container _+S R:O *k_- ::Z FS R .

Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9522-0003-009F 11/6/06 0734 TS G BP X 9522-0003-01 IF 11/6/06 0737 TS G BP X 9522-0003-01OF 11/6/06 0739 TS G BP X 9522-0003-012F 11/6/06 0741 TS G BP X 9522-0003-014F 11/6/06 0800 TS G BP X 9522-0003-015F 11/6/06 0803 TS G BP X 9522-0003-013F 11/6/06 0805 TS G BP X 9522-0003-016F 11/6/06 o TS G BP _ _

jIIS NOTES: PO #: 002332 MSR #: 06-4-ý- SSWP# NA Z LTP QA E] Radwaste QA L Non QA Samples Shipped Via: Internal Container 1//5- Z Fed Ex Temp.: -A_ Deg.

U] UPS C HI 1and Custody Sealed?

YW N-_7 1)Relinq' Date/Time 2) Received By Date/Time Custody Seal U Other Intact?

3) 1inquished By Ydf N:1 Date/Time 4) Received By Date/Time 7T19--"W/ 6"2 Bill of Lading #

Connecticut Yankee CY.ISC-SOW-O01 Statement of Work for Analytical Lab Services - -

Figure 1. Sample Check-in List KPf Date/Time. Received: j "A sDG#* t5 . *":

WorkOrder Number: i7 -

shipping C, ntainer I Chain of Cust.Y.

-Yes No["

1. Custody Seals onTshipping container intact?...

Custody Seals dated and signed? Yes (tL4No []

2.

3. Chain-of-Custoly record present? YeS [ .N.o[ ]

. 4. Cooler tenperature

5. Vermiculitepacking materials is:' Wet [ I Dry t"]A4.

6.-. Number of samples in shipping container 1 ..

7. Sample holding times exceeded? Yes [ No
8. Samples have-

_ha~zard labels '

custody seals " appropriate sample labels

9. Samples are:

-ýimgoodcondition ceaking broken -have air bubbles

10. Wera any anomalies identified in sample receipt? Yes [ ] No * '-'

IL.. Description ofanomalies.(include sample numbers):

s.ample, CustodiasL.bratory a- z. Date: /-i -0" Telephoned to: y . -

20

SAMPLE RECEIPT & REVIEW FORM PM use only Client: Gc y- ( 4,ý 1 \/+ dpj_ SDG/ARCOCIWork Order:. 15 -, V75901 Date Received: PM(A) Review (ensure non-coof rming items are resolved prior to signing):

Received By:

Sample Receipt Criteria

  • z z Comments/Qualifiers (Required for Non-Conforming Items) other (describe)

Circle Applicable: seals broken damaged container leaking container 1 Shipping containers received intact and sealed? T_ ,,

Samples requiring cold Circle Coolant # ice bags blue ice dry ice none other describe) 2 preservation within (4 +/- 2 )?

Record preservation method. __

3Chain of custody documents included with shipment?

4 [Sample containers intact and Circle Applicable: seals broken damaged container leaking container other (describe) sealed?

5Samples requiring chemical Sample IDs. containers affected and observed pH:

Spreservation at proper pH?

VOA vials free of headspace Sample ID's and containers affected:

6 (defined as < 6mrnm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory)

.Samples received within holding ids and te a ted:

time?

9 ISample ID's on COC match ID's Sample UDs and inrs affected:

-on bottles? CO Date & time on COC match date Sample ID's affected:

10 & time on bottles?

Number of containers received Sample ID's affected:

match number indicated on COC?

1COC form is properly signed in 12 relinquished/received sections?

Air Bill ,Tracking #'s, &

14 Additional Comments.

nomtoi"b. "

  • .SuspeetedH~~~~~~~dC

!!!" RSOp RAD Receipt #* "" -," :i". .:

Susecte Hazard Information f> x2 area background is observed on:Samples:identified asg mno-Zf regulated/non-radioactive-, contact-the Radiation Safejtygroup frfUrther*

______________________ x iinvestigation.

.IRadioogical -Cassifiation? aximum Counts Observed*:.

" PPed Ma . azardous D"T Material? I6f yes, contact Waste azard Class Shipped:

Manager or BSH Manager. N#:

PM (or PMA) review of Hazard classification: v" Initials Date: Itt,, ..

U 21

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00I Major Chain of Custody Form N.20-08 Connecticut Yankee Atomic Power Company Cso. 2006-00695 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested :Lb*4Usef 0'ly Contact Name & Phone: Co°mimhents:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 5 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones U0 Priority: E] 30D. [] 14 D. 0 7 D. ' 3 D. C -7 Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9522-0004-p 0 i [.) 0 T. TS G BP * -- -

0)5Y2 - tosjJt~F1 6; 62 7f 6-

,*-2 ,.A- Oil- /or

.r.C.A- 67 3A Tý W . op . A . .....

91)2)- t::'- oL: ii2 4tl/)/i /*Y h (. ,f..... jj -.... _

f .1)- Y2 77 1 - -C -L IS))- 't'"1-o9F. It

  • 11)I16 o Tr Ti .... __

NOTES: PO #: 002332 SSWP# NA 0 LTP QA 0I Radwaste QA Samples Shipped Via: .tinternal Container 0l Non QA MSR~~

  1. 6(13t 0 Fed Ex Temp.: __Deg.

FI ups El Hand Custody Sealed?

YE3 NE3

1) Relinquished By Date/Time 2) vedate/Ti*e Custody Seal El Other IJntact?
3) Relinquished By Date/Time 4) Received By DateJTime y.E ýE Bill of Lading #

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major Chain of Custody Form N.20-08 Connecticut Yankee Atomic Power Company No. 2006-00686 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested LabUseOnly Contact Name & Phone: Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 5 2040 Savage Road. Charleston SC. 29407 J <

843 556 8171. Attn. Cheryl Jones c Priority: E] 30D.[] 14 D. Z 7 D, [:13 D. C Container [-* , "*(.

Sample Size-Sample Designation Date Time Media Type &Type Comment, Preservation Lab Sample ID Code Code Code 9522-0004-OHP I0,.2lu OqVj TS G BP CqM> ")ý 0y)-, i0) TL t2 ~

7w)- - P

____ __._-

________ ____ .

NOTES: PO #: 002332 MSR #: 06-14V-3 SSWP# NA (Z LTP QA F Radwaste QA ED Non QA Samples Shipped Via: Intemal Container 16060 [ Fed Ex Temp.: Deg.

El UPS "C FI Hand Custody Sealed?

Y [I N [I Custody Seal

1) Relinquished By Date/Time 2) , ed By LI

_L _tlu,id,, toDate/,I'me

/

to Other Intact?

3) Relinquished By Date/Time 4) Received By Date/Time YO NEI Bill of Lading #

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Rcccivcd:. I i -. >D, D 1 0l i 0 SDG#:h NA 15 t-L, t0 --

Work Order Number: 12.- , " qC Shipping Container ID: Cof a in Custody #

I. Custody Seals on shipping container intact? Yes ý'No [

2. Custody Seals dated and signed? YesAl No [I
3. Chain-of-Custody record present? Yes [XNo []
4. Cooler temperature e . 0 0 ( sh" e+'7, I
5. Venniculite/packing materials is: Wet [ ] Dry 1ý
6. Number of samples in shipping container:
7. Sample holding times exceeded? Yes [] No
8. Samples have:

X_ _tape hazard labels

-custody seals _ appropriate sample labels

9. Samples are:

_. _in good condition - leaking broken have air bubbles

10. Were any anomalies identified in sample receipt'? Yes No [X_

II. Description of anomalies (include sample numbers): n Sample Custodian/Laboratory: , .&4 Date: /(P3 cB(

Telephoned to: On -_____By___________

Page 45 of 56 24

U~~* SAMPLE RECEIPT & REVIEW FORM PM am ealy jClient: A 1. Yrr V0-N~ k¶ SDG/ARCOCIWork Order:.l 9c Date Received:

P(A) Review -co a mem are nsolved rior j 2 Sample Receipt Criteria

  • Comments/Qualiflers (Required rer Non-ConfoMin Items)

SShipping containers received intact - Circle Applicable: swals broken daraged counminer leaking container oa(dcribe) and sealed? _

Samples requiring cold Circle Coolad I Ice bags blue ke dry ie none describe) 2 preservation within (4 +/- 2 C?

Record preservation method. ,, 5Y e..*eA c-Chain of custody documents included with shipment? _sb d 4-- Sample containers

,sealed?-= m* intact and /Circle Applicable: w15broen damaged conaintr leaking container odesuibc)

Samples requiring chemical Sample ID's. containers affected and observed pH:

preservation at proper pH?

VOA vials free of headspace Sample ID" mild containers'affected 6 (defined as < 6mm bubble)?

Are Encore containers present?

7 (If yes, immediately deliver to VOA laboratory)

Samples received within holding ,f/

Id's and tests affected: a 8time?

9:Sample ID's on COC match ID's Sampe ID's and containers affected:

9 on bottles? _

& time on COC match date Sample ID's affected:

0 Date

& time on bottles? __i__

Number of containers received /Sample I's affee:

- match number indicated on COC'?

COC form is properly signed in relinquished/received sections? _ _ __ ___

Air Bill ,Tracking #'s. &

14 Additional Comments 60

'7civ 0 o~~9[(

ICA'g

-?09.2a 3-1; RSOAD Receipt # ____________

Z * *If> x2 area background is observed on samples identified na-Suspected Hazard Information regulated/non-radioactive'. contact the Radiation Safety group or further 9C investigation.

, Radiological Classification? Maximum Counts Observed*: 0

'SFh*Rgipp edDO '

as Hazardou C Material? If yes, contact Waste a*god Class Shipped:

Manager or ESH Manager.

PMSeguatedasa oreign (or PMA) review ofOf H

Hazard classification: je! initials { ,-"I* As Date:

Date: "0 I

0 25

b SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM rlq 0 rl

  • O~~oG-ýC) 0 tD (o~o 0

.)c C) 6a

_______- oeoeo'

__!_ - OQ 6K<?

26

Re: Additional analyses (Sr-90)

Subject:

Re: Additional analyses (Sr-90)

From: Cheryl Jones <c @gel.com>

Date: Tue, 12 Dec 2006 07:55:22 -0500 To: "Arthur L. Hammond" <Hammond@CYAPCO.com>

CC: David Wojtkowiak <wojtkowiak@cyapco.com>, Jack McCarthy <mccarthy@cyapco.com>

Arthur, The sample listed for recount below (9522-0004-004F) is already being processed as a reanalysis for Sr-90 based on Jack's email last Friday (new workorder 177405). It will be completed this Friday and I will reference the new MSR# below. The remaining samples have been relogged per your request yesterday and will be processed on a 7d TAT. Please let me know if you have any questions.

Thanks, Cheryl Arthur L. Hammond wrote:

Cheryl, I put a 7 day TAT on the MSR however, if you have the results sooner we will take them.

Thank you, Arthur


Original Message -----

From: Cheryl Jones [1] Sent: Monday, December 11, 2006 4:33 PM To: Arthur L. Hammond Cc: Clyde Newson; John McCarthy; Jeffrey D. Wagner; David Wojtkowiak; Amanda Rasco

Subject:

Re: Additional analyses (Sr-90)

Arthur, Thank you for the list of IDs, we will have the samples pulled from their storage location and rescheduled by tomorrow morning. When do you need this data returned to you (TAT)?

Cheryl Arthur L. Hammond wrote:

Cheryl, We are requesting additional analyses on the attached list of samples.

One sample, 9522-0004-004F, is a recount. The GEL sample ID for that sample is 176890005. We are requesting Sr-90 analyses counts on these samples. The MSR NO 06-1549.

Thank you, I of 2 12/12/2006 7:55 AP 27

Re: Additional analyses (Sr-90)

Arthur Cheryl A. Jones Project Manager/PM Team Leader General Engineering Laboratories, LLC 2040 Savage Road Charleston, SC (USA) 29407 Direct: 843.769.7388 Main: 843.556.8171 x 4243 Fax: 843.766.1178 E-mail: c3g e .com Web: . Com 2 of 2 12/12/2006 7:55 AP 28

12/11/2006 MEMORANDUM To: Art Hammond From: Dave Wojtkowiak In support of the FSS of Survey Area 9522, I would like to request additional analysis for Sr-90 in the following soil samples:

9522-0001 -001 F 9522-0003-003F 9522-0001-002F 9522-0003-004F 9522-0001-003F 9522-0003-005F 9522-0001-004F 9522-0003-007F 9522-0001-005F 9522-0003-008F 9522-0001-006F 9522-0003-009F 9522-0001-009F 9522-0003-01OF 9522-0001-01 OF 9522-0003-011 F 9522-0001 -011 F 9522-0003-012F 9522-0001-012F 9522-0003-013F 9522-0001-013F 9522-0003-014F 9522-0001-015F 9522-0003-015F 9522-0001-016F 9522-0004-001 F 9522-0001-021-I 9522-0004-002F 9522-0001-024-1 9522-0004-003F 9522-0002-002F 9522-0004-004F (recount) 9522-0002-003F 9522-0004-005F 9522-0002-005F 9522-0004-006F 9522-0002-007F 9522-0004-008F 9522-0002-008F 9522-0004-009F 9522-0002-01 OF 9522-0004-01OF 9522-0002-011 F 9522-0004-011 F 9522-0002-012F 9522-0004-012F 9522-0002-013F 9522-0004-013F 9522-0002-014F 9522-0004-014F 9522-0002-01 6F 9522-0004-015F 9522-0003-001 F 9522-0004-016F 9522-0003-002F Connecticut Yankee FSS Survey Area 9522 Page 1 of 1 29

RE: Additional analyses (Sr-90)

Subject:

RE: Additional analyses (Sr-90)

From: "Arthur L. Hammond" <Hcammond@CYAPCO.com>

Date: Wed, 13 Dec 2006 16:00:57 -0500 To: "Cheryl Jones" <cj@gel.com>

CC: "Clyde Newson" <Newson@CYAPCO.com>, "David Wojtkowiak" <wojtkowiak@cyapco.com>,

"John McCarthy" <McCarthy@ CYAPCO.com>, "Jeffrey D. Wagner" <Wagner@CYAPCO.com>

Cheryl, As per our conversation sample, 9522-0004-004F, will not need a third recount. It is my understanding that Jack McCarthy had previously requested a recount on this sample on 12/8/06.

Thank you, Arthur


Original Message-----

From: Cheryl Jones [2]

Sent: Monday, December 11, 2006 4:33 PM To: Arthur L. Hammond Cc: Clyde Newson; John McCarthy; Jeffrey D. Wagner; David Wojtkowiak; Amanda Rasco

Subject:

Re: Additional analyses (Sr-90)

Arthur, Thank you for the list of IDs, we will have the samples pulled from their storage location and rescheduled by tomorrow morning. When do you need this data returned to you (TAT)?

Cheryl Arthur L. Hammond wrote:

Cheryl, We are requesting additional analyses on the attached list of samples.

One sample, 9522-0004-004F, is a recount. The GEL sample ID for that sample is 176890005. We are requesting Sr-90 analyses counts on these samples. The MSR NO 06-1549.

Thank you, Arthur Cheryl A. Jones Project Manager/PM Team Leader General Engineering Laboratories, LLC 2040 Savage Road Charleston, SC (USA) 29407 1 of2 12/13/2006 4:11 P1 30

RE: Additional analyses (Sr-90)

Direct: 843.769.7388 Main: 843.556.8171 x 4243 Fax: 843.766.1178 E-mail: c itcaei. om Web: e I :.geC*cM The information contained in this message is confidential and is intended only for the use of the individual or firm of record. If you are not the intended recipient and have received this message in error, you are asked not to copy or distribute any of the pages that follow. Please notify the sender immediately by telephone or email if you have received this communication in error and destroy the contents that do not pertain to your business with The GEL Group, INC.

2 of 2 12/13/2006 4:11 P1 31

Data Review Qualifier Definitions 32

Data Review Qualifier Definitions Qualifier Explanation

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound
  • Result is less than value reported

> Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank B Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample d 5-day BOD-The 2:1 depletion requirement was not met for this sample E Organics-Concentration of the target analyte exceeds the instrument calibration range E Metals-%difference of sample and SD is >10%. Sample concentration must meet flagging criteria H Analytical holding time was exceeded h Preparation or preservation holding time was exceeded J Value is estimated N Metals-The Matrix spike sample recovery is not within specified control limits N Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC). Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound Z Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417 , 2040 Saage Road (29407)

Phone (843) 556-8171 - Fa&3) 766-1178 www.gel.com

RADIOLOGICAL ANALYSIS 34

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 177540 Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 595174 Prep Batch Number: 595088 Dry Soil Prep GL-RAD-A-021 Batch Number: 595084 Sample ID Client ID 177540021 9522-0002-01OF 177540022 9522-0002-011F 177540023 9522-0002-012F 177540024 9522-0002-013F 177540025 9522-0002-014F 177540026 9522-0002-016F 177540027 9522-0003-OO1F 177540028 9522-0003-002F 177540029 9522-0003-003F 177540030 9522-0003-004F 177540031 9522-0003-005F 177540032 9522-0003-007F 177540033 9522-0003-008F 177540034 9522-0003-009F 177540035 9522-0003-01 OF 177540036 9522-0003-01 IF 177540037 9522-0003-012F 177540038 9522-0003-013F 177540039 9522-0003-014F 177540040 9522-0003-015F 1201245012 Method Blank (MB) 1201245013 177540021(9522-0002-01 OF) Sample Duplicate (DUP) 1201245014 177540021(9522-0002-010F) Matrix Spike (MS) 1201245015 Laboratory Control Sample (LCS) 35

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 177540021 (9522-0002-010F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

36

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 595177 Prep Batch Number: 595089 Dry Soil Prep GL-RAD-A-021 Batch Number: 595086 Sample ID Client ID 177540041 9522-0004-OO1F 177540042 9522-0004-002F 177540043 9522-0004-003F 177540045 9522-0004-005F 177540046 9522-0004-006F 177540047 9522-0004-008F 177540048 9522-0004-009F 177540049 9522-0004-01OF 177540050 9522-0004-01 IF 177540051 9522-0004-012F 177540052 9522-0004-013F 177540053 9522-0004-014F 177540054 9522-0004-015F 177540055 9522-0004-016F 1201245020 Method Blank (MB) 1201245021 177540041(9522-0004-001F) Sample Duplicate (DUP) 1201245022 177540041(9522-0004-001F) Matrix Spike (MS) 1201245023 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

37

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volumes in this batch.

Designated QC The following sample was used for QC: 177540041 (9522-0004-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1201245020 (MB), 177540041 (9522-0004-001F), 177540042 (9522-0004-002F),

177540043 (9522-0004-003F), 177540047 (9522-0004-008F), 177540050 (9522-0004-011 F),

177540052 (9522-0004-013F) and 177540054 (9522-0004-015F) were recounted due to a suspected blank false positive. Samples 1201245020 (MB) and 1201245021 (9522-0004-001F) were recounted due to high MDAs.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

38

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 597316 Prep Batch Number: 595087 Dry Soil Prep GL-RAD-A-021 Batch Number: 595082 Sample ID Client ID 177540001 9522-0001 -001F 177540002 9522-0001-002F 177540003 9522-0001-003F 177540004 9522-0001-004F 177540005 9522-0001-005F 177540006 9522-0001-006F 177540007 9522-0001-009F 177540008 9522-0001--OOF 177540009 9522-0001-01 IF 177540010 9522-0001-012F 177540011 9522-0001-013F 177540012 9522-0001-015F 177540013 9522-0001-016F 177540014 9522-0001-021-1 177540015 9522-0001-024-1 177540016 9522-0002-002F 177540017 9522-0002-003F 177540018 9522-0002-005F 177540019 9522-0002-007F 177540020 9522-0002-008F 1201250079 Method Blank (MB) 1201250080 177540001(9522-0001-001F) Sample Duplicate (DUP) 1201250081 177540001(9522-0001-001 F) Matrix Spike (MS) 1201250082 Laboratory Control Sample (LCS)

SOP Reference 39

Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 177540001 (9522-0001-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1201250080 (9522-0001-001F), 177540003 (9522-0001-003F), 177540004 (9522-0001-004F), 177540005 (9522-0001-005F), 177540006 (9522-0001-006F), 177540009 (9522-0001-01 IF), 177540010 (9522-0001-012F) and 177540015 (9522-0001-024-I) were recounted due to a suspected false positive. Samples were reprepped due to high relative percent difference/relative error ratio.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

40

Additional Comments The MDA for sample 177540001 (9522-0001-001F) was used to calculcate the relative percent difference.

Oualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date: .V rmnl .2172.144 41

SAMPLE DATA

SUMMARY

42

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-1549 GEL Work Order: 177540 The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria
    • Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-OO1F Project: YANK01204 Sample ID: 177540001 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 09-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 29.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.0168 +/-0.0162 0.0147 +/-0.0162 0.0314 pCi/g KSD1 12/21/06 1601 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-OOIF Project: YANK01204 Sample ID: 177540001 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1' UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 lnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-002F Project: YANK01204 Sample ID: 177540002 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 09-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 28.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.0128 +/-0.0177 0.0162 +/-0.0177 0.036 pCi/g KSD1 12/21/06 1601 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB] 12/12/06 1340 595082 The following Analytical Methods were performed Method Description 1 EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 80 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 80 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected 46

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-002F Project: YANK0 1204 Sample ID: 177540002 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-003F Proiect: YANK0 1204 Sample ID: 177540003 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 09-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 32.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 0.042 +/-0.0207 0.0136 +/-0.0208 0.0304 pCi/g KSDI 12/22/06 1204 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description 1 EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-003F Project: YANK01204 Sample ID: 177540003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

49

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-004F Project: YANK01204 Sample ID: 177540004 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 09-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 42%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0319 +/-0.0236 0.017 +/-0.0236 0.0376 pCi/g KSDI 12/22/06 1204 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 59 (25%-125%)

Cartier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 59 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected 50

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-004F Project: YANKO 1204 Sample ID: 177540004 Client ID: YANKO01 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company ý Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-005F Project: YANK01204 Sample ID: 177540005 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 09-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 38.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0179 +/-0.0179 0.0133 +/-0.0179 0.0296 pCi/g KSD1 12/22/06 1204 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 73 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 73 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected 52

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-005F Project: YANKO 1204 Sample ID: 177540005 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-006F Project: YANKO 1204 Sample ID: 177540006 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 09-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 44.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 0.159 +/-0.0263 0.012 +/-0.0266 0.0264 pCi/g KSDI 12/22/06 1204 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description 1 EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 88 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 88 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected 54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis I Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-006F Project: YANK01204 Sample ID: 177540006 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 lnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-009F Proiect: YANK01204 Sample ID: 177540007 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 09-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 12.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.000197 +/-0.0178 0.0149 +/-0.0178 0.0327 pCi/g KSDI 12/21/06 1602 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 82 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 82 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

56

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Anlvsi Certiicatof Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-009F Project: YANK01204 Sample ID: 177540007 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-01 OF Project: YANK01204 Sample ID: 177540008 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 09-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 29.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1I Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0288 +/-0.0241 0.0173 +/-0.0241 0.0388 pCi/g KSDI 12/21/06 1608 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB] 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 74 (25%-1 25%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 74 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-OIOF Project: YANK01204 Sample ID: 177540008 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

59

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-01 IF Project: YANK01204 Sample ID: 177540009 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 09-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 18.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U -0.00662 +/-0.0149 0.0131 +/-0.0149 0.0289 pCi/g KSDI 12/22/06 1204 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 80 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 80 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-011F Project: YANK01204 Sample ID: 177540009 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

61

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-012F Proiect: YANK01204 Sample ID: 177540010 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 09-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 12.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 0.037 +/-0.0177 0.0118 +/-0.0177 0.026 pCi/g KSDI 12/22/06 1204 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 88 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 88 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-012F Project: YANKO01204 Sample ID: 177540010 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-013F Project: YANK01204 Sample ID: 177540011 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 09-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 10.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0335 +/-0.0235 0.0139 +/-0.0235 0.0343 pCi/g KSD1 12/21/06 1658 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 81 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 81 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more 64

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-013F Project: YANK01204 Sample ID: 177540011 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

65

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-015F Project: YANK01204 Sample ID: 177540012 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 09-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 12%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.000807 +/-0.0199 0.0166 +/-0.0199 0.0381 pCi/g KSD1 12/21/06 1658 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 75 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 75 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected 66

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-015F Project: YANK0 1204 Sample ID: 177540012 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

67

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-016F Proiect: YANKO 1204 Sample ID: 177540013 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 15-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 23.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.00289 +/-0.0178 0.0153 +/-0.0178 0.0354 pCi/g KSDI 12/21/06 1859 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 105 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 105 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected 68

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-016F Proiect: YANK01204 Sample ID: 177540013 Client ID: YANKOO I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

69

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-021-I Project: YANK01204 Sample ID: 177540014 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 16-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 16.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch N Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0164 +/-0.0169 0.0112 +/-0.0169 0.0275 pCi/g KSDI 12/21/06 1859 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 100 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 100 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

70

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-021-1 Project: YANKO 1204 Sample ID: 177540014 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

71

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-024-I Proiect: YANK01204 Sample ID: 177540015 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 21-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 44.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.026 +/-0.0185 0.0119 +/-0.0185 0.0281 pCi/g KSDI 12/22/06 1205 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 105 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 105 (25%- 125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected 72

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0001-024-I Proiect: YANK01204 Sample ID: 177540015 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

73

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-002F Proiect: YANK01204 Sample ID: 177540016 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 30-OCT-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 18.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U -0.0095 +/-0.0171 0.0158 +/-0.0171 0.0366 pCi/g KSDI 12/21/06 1859 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFP1 SC,r90, solid-ALL FSS 104 (25%-125%)

Carrier/Tracer Recovery GFP1 SC,r90, solid-ALL FSS 104 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected 74

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-002F Project: YANK01204 Sample ID: 177540016 Client ID: YANK00 I Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1 U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

75

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-003F Proiect: YANK01204 Sample ID: 177540017 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 30-OCT-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 14.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch IA Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.00348 +/-0.0155 0.0125 +/-0.0155 0.0292 pCi/g KSD1 12/22/06 1205 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFP( Sr90, solid-ALL FSS 107 (25%-125%)

Carrier/Tracer Recovery GFP( Sr90, solid-ALL FSS 107 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected 76

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-003F Project: YANK01204 Sample ID: 177540017 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

77

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-005F Proiect: YANK01204 Sample ID: 177540018 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 30-OCT-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 17.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0267 +/-0.0237 0.0168 +/-0.0237 0.0384 pCi/g KSDI 12/21/06 1900 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 109 (25%-1 25%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 109 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected 78

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-005F Proiect: YANKO 1204 Sample ID: 177540018 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1I U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

79

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-007F Project: YANKO 1204 Sample ID: 177540019 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 30-OCT-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 20.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gas Flow Proportional Counting GFPC,SO9O, solid-ALL FSS Strontium-90 U 0.00433 +/-0.0171 0.0137 +/-0.0171 0.0322 pCi/g KSDI 12/21/06 1900 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFP( Or90, solid-ALL FSS 107 (25%-125%)

Carrier/Tracer Recovery GFP( Or90, solid-ALL FSS 107 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected 80

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-007F Project: YANK01204 Sample ID: 177540019 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1I U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

81

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-008F Project: YANK01204 Sample ID: 177540020 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 30-OCT-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 28.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.0235 +/-0.0229 0.0164 +/-0.0229 0.0375 pCi/g KSDI 12/21/06 1900 597316 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1340 595082 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified 3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 107 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 107 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected 82

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-008F Project: YANK01204 Sample ID: 177540020 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

83

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-010F Proiect: YANK01204 Sample ID: 177540021 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 30-OCT-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 9.97%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 0.0584 +/-0.0287 0.0155 +/-0.0288 0.0374 pCi/g KSDI 12/15/06 1439 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification 84

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-01OF Project: YANK01204 Sample ID: 177540021 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch I\

X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

85

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-01 IF Proiect: YANK01204 Sample ID: 177540022 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 30-OCT-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 20.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.0187 +/-0.0244 0.021 +/-0.0244 0.0433 pCi/g KSDI 12/15/06 1823 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 65 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 65 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 86

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-01IF Project: YANK01204 Sample ID: 177540022 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1l Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

87

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr, Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-012F Proiect: YANKO01204 Sample ID: 177540023 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 30-OCT-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 23%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.0332 +/-0.0184 0.018 +/-0.0184 0.0387 pCi/g KSD1 12/15/06 1823 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFP C, Sr90, solid-ALL FSS 65 (25%-125%)

Carrier/Tracer Recovery GFP C, Sr90, solid-ALL FSS 65 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 88

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-012F Project: YANKO 1204 Sample ID: 177540023 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

89

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-013F Proiect: YANKO01204 Sample ID: 177540024 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 30-OCT-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 22.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 0.0663 +/-0.0236 0.0154 +/-0.0237 0.0335 pCi/g KSDI 12/15/06 1823 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFP(C,Sr90, solid-ALL FSS 75 (25%-125%)

Carrier/Tracer Recovery GFP(C,Sr90, solid-ALL FSS 75 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 90

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-013F Project: YANK01204 Sample ID: 177540024 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

91

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-014F Project: YANK01204 Sample ID: 177540025 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 30-OCT-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 22.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 0.122 +/-0.0325 0.0134 +/-0.0327 0.0319 pCi/g KSDI 12/15/06 1824 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 75 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 75 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 92

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-014F Project: YANKO01204 Sample ID: 177540025 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

93

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-016F Project: YANKO 1204 Sample ID: 177540026 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 30-OCT-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 42.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0131 +/-0.0182 0.0139 +/-0.0182 0.0311 pCi/g KSDI 12/15/06 1824 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1237 595084 The following Analytical Methods were performed Method Description 1 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery % Acceptable Limits Strontium-90 GFP'C, Sr90, solid-ALL FSS 79 (25%-125%)

Carrier/Tracer Recovery GFP'C, Sr90, solid-ALL FSS 79 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 94

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Certficae ofnakis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0002-016F Project: YANKO01204 Sample ID: 177540026 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

95

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-001F Project: YANK01204 Sample ID: 177540027 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 03-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 5.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0111 +/-0.0195 0.0156 +/-0.0195 0.0337 pCi/g KSDI 12/15/06 1824 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFP(C,Sr90, solid-ALL FSS 75 (25%-125%)

Carrier/Tracer Recovery GFP(C,Sr90, solid-ALL FSS 75 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 96

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-00F Project: YANK01204 Sample ID: 177540027 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

97

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-002F Project: YANKO 1204 Sample ID: 177540028 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 03-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 8.78%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 0.121 +/-0.0277 0.0158 +/-0.028 0.0344 pCi/g KSDI 12/15/06 1824 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery % Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 74 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 74 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 98

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-002F Project: YANKO 1204 Sample ID: 177540028 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

99

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-003F Project: YANKO01204 Sample ID: 177540029 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 03-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 19.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 0.0478 +/-0.0239 0.0163 +/-0.024 0.0359 pCi/g KSD1 12/15/06 1824 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 69 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 69 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UL Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 100

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-003F Project: YANK01204 Sample ID: 177540029 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

101

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-004F Project: YANK01204 Sample ID: 177540030 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 03-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 19.6%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 0.0504 +/-0.0263 0.0167 +/-0.0263 0.038 pCi/g KSDI 12/15/06 1824 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 63 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 63 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 102

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-004F Project: YANK01204 Sample ID: 177540030 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

103

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-005F Proiect: YANK0 1204 Sample ID: 177540031 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 03-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 9.28%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 0.0377 +/-0.0217 0.0146 +/-0.0217 0.0327 pCi/g KSDI 12/15/06 1824 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 75 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 75 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification 104

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-005F Proiect: YANK01204 Sample ID: 177540031 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

105

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-007F Project: YANKO 1204 Sample ID: 177540032 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 03-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 19.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U -0.0227 +/-0.0165 0.0153 +/-0.0165 0.0328 pCi/g KSDI 12/15/06 1824 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 77 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 77 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 106

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-007F Project: YANK01204 Sample ID: 177540032 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

107

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-008F Project: YANK01204 Sample ID: 177540033 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 03-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 26.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 0.0447 +/-0.0138 0.0102 +/-0.0139 0.0212 pCi/g KSD1 12/15/06 1929 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 73 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 73 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 108

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-008F Project: YANKO01204 Sample ID: 177540033 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

109

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-009F Project: YANK01204 Sample ID: 177540034 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 06-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 10.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1I Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 0.024 +/-0.0122 0.00949 +/-0.0122 0.0197 pCi/g KSDI 12/15/06 1928 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 74 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 74 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 110

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Certilcat of~nlvsi Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-009F Project: YANKO 1204 Sample ID: 177540034 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

1il

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-01 OF Project: YANK01204 Sample ID: 177540035 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 06-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 4.79%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.00579 +/-0.0111 0.00953 +/-0.0111 0.0198 pCi/g KSDI 12/15/06 1928 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 112

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-OIOF Project: YANKO01204 Sample ID: 177540035 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

113

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-01IF Project: YANK01204 Sample ID: 177540036 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 06-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 8.03%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1I Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.00757 +/-0.0129 0.0111 +/-0.0129 0.0229 pCi/g KSD1 12/15/06 1928 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 73 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 73 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 114

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-01F Project: YANK01204 Sample ID: 177540036 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

115

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-012F Proiect: YANK01204 Sample ID: 177540037 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 06-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 12.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.0083 +/-0.0114 0.00982 +/-0.0114 0.0204 pCi/g KSDI 12/15/06 1928 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 75 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 75 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 116

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-012F Project: YANK01204 Sample ID: 177540037 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

117

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-013F Proiect: YANK01204 Sample ID: 177540038 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 06-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 14.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.00789 +/-0.00969 0.00786 +/-0.00969 0.0163 pCi/g KSD1 12/15/06 1928 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 87 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 87 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 118

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis  !

Certiira t-at Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-013F Project: YANK01204 Sample ID: 177540038 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A' Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

119

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-014F Project: YANK0 1204 Sample ID: 177540039 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 06-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 4.71%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1r Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U -0.0145 +/-0.0102 0.0091 +/-0.0102 0.0189 pCi/g KSDI 12/15/06 1928 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 75 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 75 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 120

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-014F Project: YANK01204 Sample ID: 177540039 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

121

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-015F Project: YANK01204 Sample ID: 177540040 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 06-NOV-06 Receive Date: 10-NOV-06 Collector: Client Moisture: 4.81%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1l Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U -0.00651 +/-0.0168 0.0142 +/-0.0168 0.0292 pCi/g KSDI 12/15/06 1928 595174 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1237 595084 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 82 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 82 (25%- 125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 122

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0003-015F Project: YANK01204 Sample ID: 177540040 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

123

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-OO1F Project: YANK01204 Sample ID: 177540041 Client ID: YANKOO Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 6.28%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.0197 +/-0.0223 0.017 +/-0.0224 0.0375 pCi/g KSDI 12/19/06 1849 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1224 595086 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

124

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-OO1F Project: YANKO01204 Sample ID: 177540041 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

125

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-002F Project: YANK01204 Sample ID: 177540042 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 3.79%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 0.0804 +/-0.0265 0.0163 +/-0.027 0.0358 pCi/g KSDI 12/19/06 1849 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1224 595086 The following Analytical Methods were performed Method Description 1 EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 77 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 77 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

126

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-002F Project: YANK0 1204 Sample ID: 177540042 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

127

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-003F Project: YANK01204 Sample ID: 177540043 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 3.6%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0236 +/-0.0222 0.0167 +/-0.0223 0.0367 pCi/g KSDI 12/18/06 1819 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1224 595086 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 77 (25%- 125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 77 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

128

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-003F Project: YANK01204 Sample ID: 177540043 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

129

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-005F Proiect: YANK01204 Sample ID: 177540045 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 5.44%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U -0.0234 +/-0.0195 0.017 +/-0.0195 0.0349 pCi/g KSD1 12/14/06 2006 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1224 595086 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 68 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 68 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 130

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-005F Project: YANK01204 Sample ID: 177540045 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

131

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-006F Project: YANK01204 Sample ID: 177540046 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 4.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.00284 +/-0.0147 0.0123 +/-0.0147 0.0253 pCi/g KSD1 12/15/06 1854 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1224 595086 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 77 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 77 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 132

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-006F Project: YANK01204 Sample ID: 177540046 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1l Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

133

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-008F Project: YANK01204 Sample ID: 177540047 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 6.58%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0368 +/-0.0239 0.0174 +/-0.024 0.0378 pCi/g KSD1 12/18/06 1819 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1224 595086 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFP( Sr90, solid-ALL FSS 77 (25%-125%)

Carrier/Tracer Recovery GFP( Sr90, solid-ALL FSS 77 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

134

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-008F Project: YANK01204 Sample ID: 177540047 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1l UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

135

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-009F Proiect: YANK01204 Sample ID: 177540048 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 9.4%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0343 +/-0.024 0.0182 +/-0.0241 0.0388 pCi/g KSD1 12/15/06 0844 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1224 595086 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 76 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 76 (25%-1 25%)

Notes:

The Qualifiers in this report are defined as follows

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 136

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-009F Project: YANKO 1204 Sample ID: 177540048 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

137

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0 OF Proiect: YANK01204 Sample ID: 177540049 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 5.53%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A%

Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.019 +/-0.025 0.020 +/-0.0251 0.0424 pCi/g KSD1 12/15/06 0844 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1224 595086 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery % Acceptable Limits Strontium-90 GFP C, Sr90, solid-ALL FSS 75 (25%-125%)

Carrier/Tracer Recovery GFP C, Sr90, solid-ALL FSS 75 (25%- 125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 138

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-OIOF Project: YANKO1204 Sample ID: 177540049 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

139

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-01IF Project: YANKO 1204 Sample ID: 177540050 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 8.26%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium- 90 0.0296 +/-0.0187 0.0131 +/-0.0188 0.029 pCi/g KSDI 12/18/06 1819 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1224 595086 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 87 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 87 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

140

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-0111F Project: YANKO01204 Sample ID: 177540050 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

141

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-012F Project: YANKO01204 Sample ID: 177540051 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 68.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0196 +/-0.024 0.019 +/-0.024 0.0405 pCi/g KSDI 12/15/06 0817 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 12/12/06 1224 595086 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 83 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 83 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 142

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-012F Project: YANK01204 Sample ID: 177540051 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1A Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

143

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-013F Project: YANK01204 Sample ID: 177540052 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 78.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U -0.00038 +/-0.0211 0.0177 +/-0.0211 0.0385 pCi/g KSD1 12/18/06 1819 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1224 595086 The following Analytical Methods were performed Method Description I EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 79 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 79 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

144

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-013F Project: YANK01204 Sample ID: 177540052 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1N UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

145

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-014F Project: YANK01204 Sample ID: 177540053 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 51.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A*

Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.0195 +/-0.0171 0.0138 +/-0.0171 0.0284 pCi/g KSD1 12/15/06 1854 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 12/12/06 1224 595086 The following Analytical Methods were performed Method Description 1 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 71 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 71 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 146

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-014F Proiect: YANK01204 Sample ID: 177540053 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1I Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

147

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-015F Proiect: YANKO01204 Sample ID: 177540054 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 10.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch A Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0359 +/-0.0237 0.0166 +/-0.0238 0.0369 pCi/g KSD1 12/18/06 1833 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1224 595086 The following Analytical Methods were performed Method Description 1 EPA 905.0 Modified 2 EPA 905.0 Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 80 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 80 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

148

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-015F Project: YANKO 1204 Sample ID: 177540054 Client ID: YANK001 Vol. Recv.:

Paramete r Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

149

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-016F Project: YANKO01204 Sample ID: 177540055 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 22-NOV-06 Receive Date: 30-NOV-06 Collector: Client Moisture: 14.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch lA Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.00675 +/-0.0157 0.013 +/-0.0157 0.0268 pCi/g KSD1 12/15/06 1854 595177 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 12/12/06 1224 595086 The following Analytical Methods were performed Method Description I EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Strontium-90 GFPC, Sr90, solid-ALL FSS 68 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 68 (25%-125%)

Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 150

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: December 22, 2006

Contact:

Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9522-0004-016F Project: YANK01204 Sample ID: 177540055 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch 1%

Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

151

I, .1 QUALITY CONTROL DATA I,

152

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: December 22, 2006 Client : Connecticut Yankee Atomic Power Page 1 of 2 362 Injun Hollow Rd East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder: 177540 Parmname NOM Sample Qual QC Units RPD% REC % Range Anlst Date Time Rad Gas Flow Batch 595174 QC1201245013 177540021 DUP Strontium-90 0.0584 0.141 pCi/g 83* (0% - 100%) KSDI 12/15/06 14:39 Uncert: +/-0.0287 +/-0.0374 TPU: +/-0.0288 +/-0.0375 QC1201245015 LCS Strontium-90 1.58 1.68 pCi/g 107 (75%-125%) 12/15/06 20:06 Uncert: +/-0.153 TPU: +1-0.161 QC1201245012 MB Strontium-90 U -0.0237 pCi/g 12/15/06 19:33 Uncert: +/-0.0106 TPU: +/-0.0106 QC1201245014 177540021 MS Strontium-90 5.15 0.0584 5.07 pCi/g 97 (75%-125%) 12/15/06 20:06 Uncert: +/-0.0287 +/-0.459 TPU: +/-0.0288 +/-0.482 Batch 595177 QC1201245021 177540041 DUP Strontium-90 U 0.0197 U -0.00914 pCi/g 0 (0% - 100%) KSDI 12/18/06 14:48 Uncert: +/-0.0223 +/-0.0185 TPU: +/-0.0224 +/-0.0185 QC1201245023 LCS Strontium-90 1.58 1.58 pCi/g 100 (75%-125%) 12/14/06 17:39 Uncert: +/-0.121 TPU: +/-0.250 QC1201245020 MB Strontium-90 U 0.00173 pCi/g 12/18/06 18:33 Uncert: +/-0.0167 TPU: +/-0.0167 QC1201245022 177540041 MS Strontium-90 4.92 U 0.0197 5.26 pCi/g 107 (75%-125%) 12/15/06 08:09 Uncert: +/-0.0223 +/-0.360 TPU: +/-0.0224 +/-0.483 Batch 597316 QC1201250080 177540001 DUP Strontium-90 U -0.0168 0.0309 pCi/g 2 (0% - 100%) KSDI 12/22/06 12:05 Uncert: +/-0.0162 +/-0.0186 TPU: +/-0.0162 +/-0.0186 QC1201250082 LCS Strontium-90 1.46 1.43 pCi/g 98 (75%-125%) 12/21/06 20:14 Uncert: +/-0.0938 TPU: +/-0.102 QC1201250079 MB Strontium-90 U -0.00679 pCi/g 12/21/06 19:01 153

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 177540 Page 2 of 2 Parmname NOM Sample Qual QC Units. RPD% REC% Range AnIst Date Time Rad Gas Flow Batch 597316 Uncert: +/-0.0159 TPU: +/-0.0159 QC1201250081 177540001 MS Strontium-90 4.25 U -0.0168 3.52 pCi/g 83 (75%-125%) 12/21/06 20:14 Uncert: +/-0.0162 +/-0.245 TPU: +/-0.0162 +/-0.257 Notes:

The Qualifiers in this report are defined as follows:

  • A quality control analyte recovery is outside of specified acceptance criteria

< Result is less than value reported

> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

154

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)

Revision 0

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)

Revision 0

SOUTHEAST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9522-0004 RELEASE RECORD Attachment 4 Survey Unit: 9522-0004 Area Description Southeast Grounds (non-protected)

Classification 1 Survey Media Surface Soils Type of Survey Final Status Survey Number of Measurements 16 Static, 35 Investigative STATISTICS on TOTAL STATISTICS on NON-POPULATION PARAMETRIC POPULATION Cs-137 Co-60 Sr-90 Cs-137 Co-60 Sr-90 DCGLop (pCi/g): 5.38E+00 2.59E+00 1.05E+00 DCGLop (pCi/g): 5.38E+00 2.59E+00 1.05E+00 Minimum Value: -1.74E-02 -2.80E-02 -2.34E-02 Minimum Value: -3.90E-03 -1.72E-02 -2.34E-02 Maximum Value: 2.66E-01 5.12E-02 1.90E-01 Maximum Value: 1.03E-01 3.62E-02 1.90E-01 Mean: 4.56E-02 7.43E-03 3.31 E-02 Mean: 4.60E-02 6.89E-03 3.31 E-02 Median: 3.34E-02 4.62E-03 2.17E-02 Median: 4.54E-02 6.20E-03 2.17E-02 Standard Deviation: 5.18E-02 1.78E-02 4.74E-02 Standard Deviation: 3.42E-02 1.42E-02 4.74E-02 DCGLsur (pCi/g): 1.41 E+00 Nuclide Distribution: 0.592 0.083 0.325 Cs-137 Co-60 Sr-90 I GPS CoordinatesrT [1[11 Fraction Sample ID Result 2 MDA I Result MDA Result I MDA I2o Identified __ 2j _ _ _ Identified _ _J 2o ~Identified of DCGL North East (pci/g) (pCl/g) (pCi/g) (pCi/g) (pCI/g) (pCi/g) 9522-0004-001F 236286.65 669067.63 4.79E-02 0.024 3.49E-02 + 1.84E-02 0.021 4.12E202 i 1.97E-02 0.022 3.75E-02 0.035 9522-0004-002F 236286.65 669100.4 7.78E-02 0.025 3.27E-02 + 1.60E-02 0.021 3.11 E-02 8.04E-02 0.027 3.58E-02 + 0.097

........ . ..........................................

.....................

......"..."

.....................

......... ............. ..... ...... t ........................ ....... ........ ............... .......  :.. ..... ..... *....... . ...... ... ............ ........ ....:..... ..... ......

9522-0004-003F

................. 236258.26

........................................... 669051.24 ...............................

0.00E+00 0.049 3.95E-02 -3.62E-03 0.026 4.58E-02 2.36E-02 0.022 3.67E-02 +

................

.............

..,............................... t...............................

...............................

..............................................................

................................

  • ,...............................

..............................

................................. ............................... ..................... 0.021 9522-0004-004F

........................ i...236258.26

............................. ....................

.... 669084.01

  • ............ 4.30E-02 I...............

...............

,.................. 0.028

........... 2.67E-02 .............

I....................

................................ + 1.57E-02

.................

...................

............. 0.015 3.04E-02 ...............................

...............................

............................... 3.50E-02

.................. 0.012

................... 1.89E-02 ................

............................... + 0.047 9522-0004-005F 236258.26 669116.79 -3.10E-03 0.016

....

. . .............

..........

....................

.........

.......... .......

"..

.........

.....................

....................

.............

.........

......... 2.73E-02

...........

........... 5.10 E-03

...................................

..........

......... 0.015

...............

t......... ............. 2.62E-02

............

................

., ..............................

............ -2.34E-02

..............

--........ 0.020 1 3.49E-02

.......... ,..................... -0.021

....................

., ... .....

9522-0004-006F 236258.26 669149.56 9.48E-02 0.045 4.33E-02 + -5.83E-03 0.030 4.97E-02 2.84E-03 0.015 2.53E-02 0.018 9522-0004-007F 236229.88 669034.85 1.46E-02 0.025 4.05E-02 1.89E-02 0.024 4.25E-02 1.90E-01 0.032 2.71 E-02 + 0.191 9522-0004-008F 236229.88 669067.63 8.05E-02 0017 1.80E-02 + 1.57E-02 0.012 2.34E-02 3.68E-02 0.024 3.78E-02 + 0.056

............................................................

F ..............................6...............................

. .............................. .......... ...............................

-................

3....................................................

...........

....................

...........

....................

...........

....................

.... ..........................

9522-0004-009F i236229.88 669100.4 5.56E-02i 0.031 '12.99E-02i + -3.76E-03i 0.018 3.13E-02i 3.43E-02i 0.024 i3.88E-02i

..........0..............

.................................

. + 0.042 REVISION 0 Pagel1 of`3

SOUTHEAST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9522-0004 RELEASE RECORD Attachment 4 Cs-137 Co-60 Sr-90

[

GPS CoordinatesFTT T Fraction Sample ID Result MDA Result MDA Result MDA 2cr ____ Identified 2cr Identified 2cr Identified of DCGL North East (pCi/g) (pC/g) (pCli/g) (pCi/g) (pCi/g) (pCilg) 9522-0004-001O F 236229.88 I...............................

669133.18 ............ 7.50E-02 0.014 ..r. ..... 1.55E-02 + O.OOE+00 ...............................

0.018 1.71E-02 1.90E-02 0.025 4.24E-02 0.032

....

........................................................

............................... ..................

r.......................... ................

i ...........................

... ................................. ."..................

...... ................................................................ ...............................

..t, .......................

.........................................................

9522-0004-0011F ....

i..............................-

23622988 ...............................

669165.95 ..............................

1.82E-02 *....

...........................

0.025 ..............................

...............................

3.92E-02 ...............................

3.62E-02 ...............

...............

0.028 *...............................

4.38E-02  !..........

................

+ 2.96E-02 ,...............................

.................................. 0.019 *.................

2.90E-02 ....... 0.046

+

9522-0004-0012F

............................................................. 4.19E-02 r...............................

669198.73 . ..............................

...............................

I.............................. 0021

.2362998...............................

2.94E-02 .......................

+ .......... 2.04E-02 0.016 +

4.02E-02 .............................. 1.96E-02 .................... 0.024*.......... 4.05E-02 0.034

.................

...............................

............................... .......................... .......

  • ........*............ .....

9522-0004-0013F

.....

........... 236201.49 I...............................

669051.24 .................

4.47E-02 0.030 +

3.29E-02 .............................. 7.30E-03 0.020........... 3.82E-02 -3.80E-04 0.021 ......... 3.85E-02 0.011

...........................................

............................... ............

...............................

v............................... ...........................................................................

  • ? .............................................................-

" ...................... .-

.................. .....

9522-0004-0014F 236201.49 669084.01 4.61 E-02 r............... 0.028 3.47E-02 + -1.30E-02 0.022 3.18E-02 1.95E-02 0.017 2.84E-02 + 0.022

......

......... ..... ...............................

.............

. .......... .......... ...................

...........

................. ........... ........

.................

....................................................

f .................................

.............. ....................

..........................................

.. ................................ ..................................

t .................

........

9522-0004-0015F 23620149 669116.79 1.03E-01 0.024 2.42E-02 + O.OOE+00 0.020 2.67E-02 3.59E-02 0.024 3.69E-02 + 0.053

...... 2.3 .....

9522-0004-0016F 0.......

0...........

F ...... 8 .0

................

236201.49 6.6

.1 669149.56 63 ..........

................. -3.90E-03 .........................

0.027 ..... ..

.........

4.07E-02 2..................... 4502

.....................................

-1.72E-02 0.025 4.20E-02 ...... ....

6.75E-03 0.016 ...........

2.68E-02 -0.001

..

......

9522-0004-001 ................... FS ................................

...............

236286.65 .. ...........

669067.63 ........

7.22E-02 ..............................

.....  ! ..................

........................

0.030 i........

2.91 E-02 ..........................

............... + 3.04E-02 ? 0.018................

...-.............................

......

3.41 .......

E-02.........................

?..............................

+ 0.063

....

,0

......................................................

9522-0004-0017, 9522-0004-0018-1 00 ............................

i 23624767 23626542 ...............................

69,,O 669176.80 669152.35 ......................

1.99E-01 8.83E-02E..... ,............................

0.076 0024 , t..................o 724E502 95E02 ..............................

+

+ ................................

391502

-4.18E-03 .......................................

0049 0.019 99li502

.48E -02 0.156 0.061 0.069 9522-0004-0020 i 236250.13 669159.45 8.18E-02 0035 3 26E-02 + 1.33E-02 0019 3.81E-02

... .... .......... ... ... ....... ................ .... ............ ....... .................................

............... ............ ... .V.. ...... .......................

... ..... ...........................

............. ... .................

.............................

.........

. ................ ..... .................... ......

0.063 9522-0004-0021-1 9522-0004-0022-1 i 2362437 236239906 669161.23 669162.91 5.02E-03

-1.06E-01 0.029 0.0234 52E-02 4.36E02 -8.99E-03

-. 23E-02 2 0.031 0.021 68E-02 4.820E02 0.000

........

....................................................

...............................

-...............................

..............................

...............................

...............................

,...............................

..............................................................

'...............................

,..... ....... ............ .......................... .......................

........

"................. .................. 0.007 9522-0004-0023-1 i 23624040 66918.36 -9.205-03 0.020 49E02 -6.50E-03 0.020 3.55E -02

-0.009

.....................

.............................

.......................

..... ..............................

...............

.......... *................

.. ....... ................ . ... .......................

..... ............................

. *...............................

  • .............................. ............. . .....................

.*. ......... . .. ..............................

".................... ........

9522-0004-0024- i 236234.68 i669162.41 1.60E-02 i 0.018 2.88E-02 Il1.1E-03 i 0.017 2 295E-02 0.012 9522-0004-0025-1 I 236238.67 669155.01 2.42E-02 0.033 5.38E-02 -6.90E-03 0.030 5.48E-02 0.020

................

......

9522-0004-0026-1 9522-0004-0027- i

................

.................................... ................

i236223.15 i669130.33 236258.12 i669068.51

. .............................

...............................

4.99E-02 5.615E-02 i

?........................

0 0029 0.038

......................................

3 390E-02I 6

603E-02 i

,..........................

+

+

..................................

-9.36E-04i 2.82E-02 i

...............................

0,021 0.037

,...............................

3 371 E-02 5

577E-02

....................

. .....................................

................................

iii iii

.......

............... 0.035 0.051 9522-004-033 I 236240840 669064.98 -9.20E-03 0.020 3.66E-02 41E 0 0 0 38E0 0.083 9522-0004-0029-1 i 23621047 669122.94 1.43E-02 0.032 .49E-02 -2.23E-02 0.028 4.82E-02 +

0.002 9522-0004-0030- i 236240.69 !669058.08 2.175-02 ! 0.036 6 657E-02 i-2.80E-02 0.057 1 1.0E-01 iii 0.005 9522-0004-0031- i 236221 38 i669064.23 5.19E-03 i 0.022 2 286E-02 i1.37E-02 i 0.015 2 298E-02 0.009 9522-0004-0032- i 236208820 669072.60 -14.04E-03 i 0 20 i 4.......1..........i02.....2....82E.....i02.....0....039.....!.3......8E.....02..

.6 E0 41E-3 .20 .8-022 0.010

-0.002 9522-0004-0034-1 i 23628167 669062.62 4.04E-03 0 032 i E1 02 -2.46.5 02 0.026 3.81E-02

-0.007 9522-0004-0035-1 236275.44 669058.24 5.41E-02 0.043 .38E-02 + 3.43E-03 0029 4 896E-02 0.040 REVISION 0 Page 2 of 3

SOUTHEAST SITE GROUNDS (NON-PROTECTED AREA)

SURVEY UNIT 9522-0004 RELEASE RECORD Attachment 4 Cs-137 Co-60 Sr-90 GPS CoordinatesT1rfT Fraction Sample ID Result MDA Result 2 MDA I Result MDA 2or Identified 2j Identified 2o Identified of DCGL North East (pCi/g) _ (pCIg) (pCi/g) (pCi/g) (pCig) (pCli/g) 9522-0004-0036-1 0.021

... 2 2 -0 . 0......

04.... 3 7.. I 236283.09

...362.............

............ 669057.08

. 2 ............... 2.63E-02 0.024 4.09E-02 + 6.25E-03 1 ..... t-..........................r...................................................

62 .......................... 0.025 4.90E-02 ........................................................................

........................................................................... "

9522-0004-0037-1

............ I..................... . .... 236251.25 669052.62

..................... ......1........

..........

."................... .23E-01 0.028

... .."........ 3.49E-02

..................

...........

......

............

...... + .......

......

...... ....3.35E-02

.............. 0.022

........ .......

.................. ......4.60E-02+

..........................

&.. ...... ................

.............. ...........

........ ... .T..................... .......................0.100

......

9522-0004-0038-1 236247.03 669048.47 3.65E-02 0.047 5.62E-02 5.12E-02 0.034 7 l1E-02 + 0.046

....... ..................

9522-0004-0039-1 ...I.....................

i .........

......................

236254.62 . .....

.......................

669046.82 ...............................

4.06E-02 t..............................

0.041 r...................

6.52E-02 ............

.....................

........

.......................

-6.38E-03 V........

................

0.029 ..... t:...............................

5.23E-02 r..............................

.............

......................

.......................

.. ......................

. 0.026 9522-0004-0040-1 i i....

........................................ ..... ................

....................

236250.49 ...................................

669043.97 ........................ 0.035 r................................................................

7.66E-02 *............................... 4.21 E-02 + .......

I...................

3.41 E-03 ..  ?...............................

00.026 *.. .......................

4M93E-02 r...

...........................

..............................

......

i ......................... ..

............................... 0.056 9522-0004-0041-1 i.... 236253.04

.................................................... " 669043.02

............

.....

.......... 6.75E-02

.............................

..................... 0.039 6.62E-02 + ...... -9.28E-03 0.037 ..

...............................

...................

...............................

.... "1

.............................. 6,63E-02 *r...............................

t.............................. ...............................

.............................. 0.044 9522-0004-0042-1 i 236249.57 669039.43 2.94E-02 0.016 1.89E-02 + 2.87E-03 0.015 2,09E-02 0.022 9522-0004-0043-1 23624800 669036.93 -1.74E-02 0.031 5.53E-02 4.26E-02 0.081 6.06E-02 0.004 9522-0004-0044-1 i 236253.80 669035.84 2.61 E-02 0.034 4.36E-02 -6.71 E-03 i 0.022 3,85E-02 0.016

..............

0....

9522-0004-0045-1 .................................

400, ..... i i.....

....

6................

90.........

236213.10 66.*............

669126.34 ......

2..............

2.66E-01 . . . ., ..................

00 ....

.40 0.031 ,.......

....

...............

4.79E-02 *.........................

+ ......................

-. i .0*

6.43E-03 ...........

0.027 ..... ...........

4,68E-02 . ... ........

................

...........................

-.. . . . . . . . . ..... ........

..............

i...................... 0.191 9522-0004-0046- ................

...............

236239.88

............................................................ ....

...........................

669151.26 ... ........................

2.45E-02 . ................ ..............

0.026 r.

...............................

3.07E-01 i......... ....................

-8.21 E-03

....... ..... .... 0.020

.......... 3.30E-02

............ r.... ........... ................ ... ...........  ?........... 0.014 9522-0004-0047-1 i ...............................

236211.67 .............................

.......................................................... 669132.31 ...... 2.04E-02

........................0.023 .... 3.59E-02 ....

................................

  • ........................... 2.31E-03 i ..............................

... ............... 0.021 ...............................

...........

"..................... 3 87E-02 ................ ................................................................

..... ...............................

................. 0.015 9522-0004-0048-1 i ............................

.....................................................

........

236221 09 ... .....................

669142.21 . 3.03E-02 .........

.....

........

......

, ...........................

0.026 .... * ...........................

4.90E-02 .... i .....................

+ ... ...... ...............................

5.58E-03 ...........

.................................................................

0.028. 5,16E-02 ................................................................

...............................

............... 0.024 9522-0004-0049-1 i 236222.28 669146.18 1.81 E-03 0.045 1 7.20E-02 1.26E-02 0.039 7.53E-02 0.006 9522-0004-0050 i 236211.25 669147.20 8.28E-04

.. ................

0025

~~~~~.................

.................................

............................................................

........ ........................

83E-02

..............................

3.43E-03 0.023

...............

4,12E-02

...........................

.............................................  ?.....................

L.... ..........

0.002 9522-0004-0051-1 i 236206.81 669147.48 8.40E-03 0.020 4.41 E-02 1.73E-02 0.022 4.17E-02 0.013 REVISION 0 Page 3 of 3

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)

Revision 0

QUANTILE PLOT FOR CESIUM-137 Survey Unit: 9522-0004 Survey Unit Name: Southeast Site Grounds (non-protected area)

Mean: 4.60E-02 pCi/g Quantile Plot For Cs-I37 1.20E-01 1.00E-01

  • 8.OOE-02

.117 1 II I

  • 0 C

6.OOE-02 "-ri ---

4.00E-02 C

0 2.OOE-02 0,00E+00 0 20 40 60 80 100 Percentage Cs-137 Rank Percentage

-3.90E-03 1 3.1%

-3. 1OE-03 2 9.4%

0.OOE+00 3 15.6%

1.46E-02 .4 21.9%

1.82E-02 5 28.1%

4.19E-02 6 34.4%

4.30E-02 7 40.6%

4.47E-02 8 46.9%

4.61 E-02 9 53.1%

4.79E-02 10 59.4%

5.56E-02 11 65.6%

7.50E-02 12 71.9%

7.78E-02 13 78.1%

8.05E-02 14 84.4%

9.48E-02 15 90.6%

1.03E-01 16 96.9%

0VJL4~C SIo1o'7 SuO mitted bd/Date

/ /I/  ?-o Revie ed by/Date

FREQUENCY PLOT FOR CESIUM-137 Survey Unit: 9522-0004 Survey Unit Name: Southeast Site Grounds (non-protected area)

Mean: 4.60E-02 pCi/g Frequency Plot For Cs-137 10 8-6+

U_

4 2-0 1.39E-02 3.17E-02 4.96E-02 6.74E-02 8.52E-02 1.03E-01 Upper End Value (pCi/g)

Upper End Observation Observation Value Frequency Frequency 1.39E-02 3 19%

3.17E-02 2 13%

4.96E 5 31%

6.74E-02 1 6%

8.52E-02 3 19%

1.03E-01 2 13%

Total: 16 100%

1.1 1010 S bmitted by ate

ýievye 6a by/Date 1 of 1

QUANTILE PLOT FOR STRONTIUM-90 Survey Unit: 9522-0004 Survey Unit Name: Southeast Site Grounds (non-protected area)

Mean: 3.3 1E-02 pCi/g Quantile Plot For Sr-90 2.OOE-01 1.80E-01 1.60E-01 1.40E-01 0) 1.20E-01 C,

1.O0E-01 C

8.00E-02 0

- -- - - - iI

  • I [

6.00E-02 0

4.OOE-02 2.00E-02 []1" -p "ui- -

0.OOE+00 0 20 40 60 80 100 Percentage Sr-90 Rank Percentage

-2.34E-02 1 3.1%

-3.80E-04 2 9.4%

2.84E-03 3 15.6%

6.75E-03 '4 21.9%

1.90E-02 5 28.1%

1.95E-02 6 34.4%

1.96E-02 7 40.6%

1.97E-02 8 46.9%

2.36E-02 9 53.1%

2.96E-02 10 59.4%

3.43E-02 11 65.6%

3.50E-02 12 71.9%

3.59E-02 13 78.1%

3.68E-02 14 84.4%

8.04E-02 15 90.6%

1.90E-01 16 96.9%

IA 118010-7 Su itted by ate A6 ASeA 1/ /

'Revi~e~w_ by/Date

FREQUENCY PLOT FOR STRONTIUM-90 Survey Unit: 9522-0004 Survey Unit Name: Southeast Site Grounds (non-protected area)

Mean: 2.26E-02 pCi/g Frequency Plot For Sr-90 14 12 U 10 8

0* 6 0

1~

U- 4 2

0 I I I -

1.22E-02 4.77E-02 8.33E-02 1.19E-01 1.54E-01 1.90E-01 Upper End Value (pCilg)

Upper End Observation Observation Value Frequency Frequency 1.22E-02 4 25%

4.77E-02 10 63%

8.33E 1 6%

1.19E-01 0 0%

1.54E-01 0 0%

1.90E-01 1 6%

Total: 16 100%

SUmitted byl te 4/0k 4Y

ý-eV Ibj/Date 1 of 1

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)

Revision 0

Connecticut Yankee Decommissioning Project GPP-GGGR-R5121-001 Attachment B, Health Physics Procedure Rev.CY-001 MAJOR Sign Test Calculation Sheet for Multiple Radionuclides Survey Area Number: 9522 Survey Unit Number: 0004 WPIR #: 2006-0047 Survey Area Name: Southeast Site Grounds Classification: 1 TYPE I (aerror): 0.05 N: 16 (non-protected area)

Radionuclides: 1st Radionuclide 2nd Radionuclide 3rd Radionuclide 4th Radionuclide Cs-137 Co-60 Sr-90 DCGL: 5.38E+00 2.59E+00 1.05E+00 Results 1 st Results 2 nd Results 3 rd Results 4 th Weighted Sum 1-Ws Sign Radionuclide Radionuclide Radionuclide Radionuclide (WS)

(pCi/g) (pCi/g) (pCi/g) (pCi/g) 4.79E-02 1.84E-02 1.97E-02 0.03 0.97 +1 7.78E-02 1.60E-02 8.04E-02 0.10 0.90 +1 0.OOE+00 -3.62E-03 2.36E-02 0.02 0.98 +1 4.30E-02 1.57E-02 3.50E-02 0.05 0.95 +1

-3.1 OE-03 5.1OE-03 -2.34E-02 -0.02 1.02 +1 9.48E-02 -5.83E-03 2.84E-03 0.02 0.98 +1 1.46E-02 1.89E-02 1.90E-01 0.19 0.81 +1 8.05E-02 1.57E-02 3.68E-02 0.06 0.94 +1 5.56E-02 -3.76E-03 3.43E-02 0.04 0.96 +1 7.50E-02 0.OOE+00 1.90E-02 0.03 0.97 +1 1.82E-02 3.62E-02 2.96E-02 0.05 0.95 +1 4.19E-02 2.04E-02 1.96E-02 0.03 0.97 +1 4.47E-02 7.30E-03 -3.80E-04 0.01 0.99 +1 4.61 E-02 -1.30E-02 1.95E-02 0.02 0.98 +1 1.03E-01 0.OOE+00 3.59E-02 0.05 0.95 +1

-3.90E-03 -1.72E-02 6.75E-03 0.00 1.00 +1 Number of positive differences (S+) 16 Critical Value 11 Survey Unit Meets the Acceptance Criteria Performed by: David WojtkowiIIk Date: 1/10/2007 Independent Review by: 17, 7 Z-Z.61z.7yDate:

/ &Z_

Page 1 of 1

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)

Revision 0

Health Physics Procedure 24265-000-GPP-GGGR-R5]24-000-Rev.CY-000 Attachment A l-leahh Physics Procedure 24265-000-GPP-GGGR-R5 I24-000-Rev.CY-000 Attachment A Split Sample Assessment Form Survey Area #: 9522 Survey Unit # 0004 Survey Unit Name: Southeast Site Grounds (non-protected area)

Sample Plan or WPIR#: 2006-0047 SML#: 9522-0004-001 Sample

Description:

Comparison of split samples collected from sample measurement location #8 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9522-0004-001 F, the comparison sample was 9522-0004-00IFS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)

Cs-137 4.79E-02 0.012 4 0.5 -2.0 7.22E-02 0.015 1.51 Y Comments/Corrective Actions: NONE Table is provided to show acceptance criteria used to assess split samples.

Resolution Agreement Ranxe 4-7 0.5 -2.0 8-15 0.6-1,66 16-50 0.75-1.33 51 -200 0.80-1.25

>200 0.85 - L 18 Performed by: D Wojtkowiak Date: Reveiwed by: Date:

1/9/2007)-2 //// -ý L)

ýýj Page I of I

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9522-0004 RELEASE RECORD ATTACHMENT 4E (COMPASS POWER CURVE)

Revision 0

DQA Surface Soil Report Assessment Summary Site: Southeast Grounds (non-protected area) 2 Planner(s): Wojo Survey Unit Name: 9522-0004 Report Number: 1 Survey Unit Samples: 16 Reference Area Samples: 0 Test Performed: Sign Test Result: Not Performed Judgmental Samples: 0 EMC Result: Not Performed Assessment

Conclusion:

Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve 1

0.9 ,_ r--IA _ -I-. _

0.8 II - . - ___I_

0.7 06 0.6 0.5 b.

V 0.4 0.3 0.2

- m 0.1 I - r _ _

0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Unity Rule Sum-ofRatios, inciudlin backgrund

- - Prospective Power U 1-beta .... Actual Power

- LBGR - - Estimated Power DCGL -- - Retrospective Power COMPASS vl.0.0 11I1012007 Page1I