Haddam Neck Plant, Final Status Survey Final Report Phase Iv, Appendix A6, Survey Unit Release Record 9106-0006, Discharge Canal
ML063400440
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 11/14/2006
From: Newson C
Connecticut Yankee Atomic Power Co
To:
NRC/FSME
References
9106-0006
Download: ML063400440 (298)


Text

Book 7 of 17 Final Status Survey Final Report Phase IV Appendix A6 Survey Unit Release Record 9106-0006, Discharge Canal November 2006 CYAPCO FINAL STATUS SURVEY RELEASE RECORD DISCHARGE CANAL SURVEY UNIT 9106-0006 Prepared By: / I ._ Date: FS er Reviewed By: Date: F ,Sp-ngineer

, Approved By: .41,, ,'. C , Date: /1 YIP6 Technical Support Manager/Revision 0 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD TABLE OF CONTENTS 1. SURVEY UNIT DESCRIPTION

.....................................................

3 2. CLASSIFICATION BASIS .............................................................

3 3. DATA QUALITY OBJECTIVES (DQO) ........................................

5 4. SURVEY DESIGN ............................................................................

8 5. SURVEY IMPLEMENTATION

..................................................

11 6. SURVEY RESULTS .......................................................................

12 7. QUALITY CONTROL ...................................................................

13 8. INVESTIGATIONS AND RESULTS ............................................

14 9. REMEDIATION AND RESULTS ................................................

15 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN ....... 15 11. DATA QUALITY ASSESSMENT (DQA) ....................................

15 12. ANOM ALIES ..................................................................................

16 13. CONCLUSIONS

..............................................................................

16 14. ATTACHM ENTS ............................................................................

17 Attachment 1 -Figures (6 pages including cover)Attachment 2 -Sample and Statistical Data (273 pages including covers)Revision 0 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9106-0006 (Discharge Canal) is designated as Final Status Survey (FSS) Class 2 and consists of approximately 9,716 m 2 (2.40 acres) of water covered sediment in an area located approximately 0.68 miles from the reference coordinate system benchmark used at the Haddam Neck Plant (HNP)(see Attachment 1, Figure 1). The Discharge Canal is a man-made mile long waterway that runs parallel to, and ultimately communicates with the Connecticut River. The Discharge Canal is subdivided into fifteen (15) survey units including two (2) permanent wetland areas for FSS purposes.

The survey unit is bounded as follows: Discharge Canal Survey Unit 9106-0005 is to the north (called north as orientated with the north to south flow of the Connecticut River), land surface area Survey Unit 9521 is to the east, Discharge Canal Survey Unit 9106-0007 is to the south and Discharge Canal area 9106-0012 (formerly a part of 9530) is to the west. The survey unit comprises the canal sediments to the deeper of three (3) feet or the original construction depth and it extends up the canal banks to the mean high water level.The reference coordinates associated with this survey unit are E026 through E032 by S120 through S133 (refer to License Termination Plan Section 5.4.4).The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10,"Survey Unit Classification. " The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9106-0006 as Class 2 in May 2006.The "Classification Basis Summary" conducted for this survey unit consisted of: a) A review of the 1OCFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment (HSA) Supplement, " c) Historic and current survey records review, d) Visual inspections and a "walkdown." e) Formal or informal interviews with cognizant personnel.

A review of the lOCFR50.75(g)(1) database report identified a number of events that may have impacted this survey unit. Several events indicated the potential for plant related contamination in the survey unit. These included a number of primary side system to secondary side system leakage events, Revision 0 3 Revision 0 3 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD contamination found to be present in secondary side systems and components, and unmonitored spills that drained to the discharge canal. In 1986, samples were taken from the legacy dredge spoils removed in 1979 dredged spoils area and from recently dredged canal sediment.

The sample analyses indicated that the concentrations of Cs-137, Co-60 and other radionuclides were a small fraction of the DCGLs for those nuclides that could be identified by gamma spectroscopy. (refer to NE-86-RA-1142 dated 11-13-86).

None the available historical information reviewed would support a conclusion that any residual activity in this survey unit is likely to be present at concentrations greater than the respective DCGLs.Additional information was provided by several historical documents, including the "Results ýof Scoping Survey", (completed 9/1/98), the "Historical Site Assessment", and the HSA Supplement (dated 6-30-00).

These documents presented the results of several sediment samples taken in 1997. These sample results indicated concentrations of 0.5 pCi/g for Co-60, 0.024 pCi/g for Cs-134 and 0.722 pCi/g for Cs-137.A final characterization was performed by Site Closure personnel in April and May of 2004. Six (6) sediment samples were taken. All of the samples were analyzed by gamma spectroscopy, Sr-90 and tritium. Additionally, Hard-to-Detect (HTD) analyses were performed on one (1) sample. The radionuclides of concern identified in the sample data for FSS planning purposes were Cesium-137, Cobalt-60 and Sr-90. All other positively detected isotopes could be screened out based on the 5%/10% rule of Section 5 of the LTP. The statistics for each of the radionuclides of concern are listed in Table 1.-asic StatisticalQuanties for- (s137 a 0 fd 99fmin the et~r:; Characterization Sm-Nu paalttrCs137 (pCi/~g) I ~Co'-6ý (jpCig)~ I Sr-90.(pCi/g)

Minimum Value: -7.59E-04 8.61E-03 1.14E-02 Maximum Value: 2.22E-01 6.14E-01 7.16E-02 Mean: 1.29E-01 2.76E-01 4.17E-02 Median: 1.64E-01 2.73E-01 3.94E-02 Standard Deviation:

1.02E-01 2.67E-01 2.50E-02 NOTE: The Operational DCGLs are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 1.18 for Sr-90; these are used in conjunction with the unity rule to achieve 19 mrem/yr TEDE The FSS Engineer performed a visual inspection and walk-down during April 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational DCGLs justifying a final survey unit classification of Class 2 (refer to Section 3).Revision 0 4 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD 3. DATA QUALITY OBJECTIVES (DQO)FSS design and planning is based on the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, 'Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM).

A summary of the main features of the DQO process are provided herein.The DQO process incorporates hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis.

Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition.

The baseline condition is technically known as the null hypothesis.

Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection.

In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria.

Rejection of the null hypothesis would satisfy the release criteria objective of the FSS.The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9106-0006 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.

This is done through the development of Derived Concentration Guideline Levels (DCGLs). The DCGLs represent the concentration of radioactivity above background, equivalent to a dose-based release criterion and is presented in terms of surface or mass activity concentrations.

Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), for existing groundwater radioactivity and for future groundwater radioactivity that will be contributed by building foundations and footings.As described in detail in the LTP, the dose model applied to the discharge canal presumes that the canal sediments are dredged to a depth of three (3) feet below the top of the sediment layer and spread for the planting of crops per the Resident Farmer Scenario.

Consequently, the soil DCGLs are directly applied to the canal sediment media.The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.Equation 1: Revision 0 5 Revision 0 5 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD HTotal=Hsoil (sediment)

+ HExisting GW + HFuture GW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.This survey unit is not affected by existing or future groundwater (reference CY memo ISC 06-024). Therefore, dose contribution from existing and future groundwater is zero (0) mrem/yr TEDE, based on field data.Equation 2: 19 mrem/yr 1 otaff 19 mrem/yrsoil+

0 mrem/yrExisting GW+ 0 mrem/yrFuture GW The allowable dose for soil in this survey unit is nineteen (19) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in nineteen (19) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.Revision 0 6 Revision 0 6 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Table 2 -Radionjuclide Specific Base Case Soil DCGL, Operational C s and Required Minimum Detectable Concentrations Radionuclide Case Soil Operational pCGL Requi red MDCo H-3 4.12E+02 3.13E+02 1.65E+01 C-14 5.66E+00 4.30E+00 2.26E-0I Mn-54 1.74E+OI 1.32E+01 6.96E-01 Fe-55 2.74E+04 2.08E+04 1.1 OE+03 Co-60 3.81E+00 2.90E+00 1.52E-01 Ni-63 7.23E+02 5.49E+02 2.89E+01 Sr-90 1.55E+00 1.1 8E+00 6.20E-02 Nb-94 7.12E+00 5.41E+00 2.85E-0I Tc-99 1.26E+OI 9.58E+00 5.04E-01 Ag- 108m 7.14E+00 5.43E+00 2.86E-0I Cs-134 4.67E+00 3.55E+00 1.87E-01 Cs-137 7.91E+00 6.01E+00 3.16E-01 Eu- 152 1.01E+01 7.68E+00 4.04E-0I Eu-154 9.29E+00 7.06E+00 3.72E-0I Eu-155 3.92E+02 2.98E+02 1.57E+01 Pu-238 2.96E+OI 2.25E+01 1.18E+00 Pu-239/240 2.67E+O I 2.03EE+01 1.07E+00 Pu-241 8.70E+02 6.61E+02 3.48E+01 Am-241 (5) 2.58E+01 1.96E+01 1.03E+00 Cm-243/244 2.90E+O I 2.20E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE (3) The Operational DCGL is equivalent to nineteen (19) mrem/yr TEDE (4) The required MDC is equivalent to one (1) mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.

Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.

The radiological data that was used to support the DQO process, was provided by the characterization surveys performed in 2004 and 2006, as discussed in Section 2. Cs-137, Co-60 and Sr-90 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137, Co-60 and Sr-90 are provided in Table 1.As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Revision 0 7 Revision 0 7 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Detectable Concentration

(<MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans ".This survey was initially designed to ten (10) mrem/yr TEDE. At the time when the survey was designed, the dose contribution for existing and future groundwater had not yet been determined.

Consequently, a conservative value was chosen for the Operational DCGL. This approach is no longer required as the total dose from existing and future groundwater has been established.

The dose for soil used for this survey unit to demonstrate compliance with the LTP criteria is nineteen (19) mrem/yr TEDE, as discussed in Section 2 of this Release Record.The DQO process determined that Cs-137, Co-60 and Sr-90 were the radionuclides of concern (refer to Section 3). The sum of fractions or unity rule was used with the individual Operational DCGLs because multiple radionuclides (Cs-137, Co-60 and Sr-90) were considered in the survey design.Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening process described in LTP Section 5.4.7.2, "Gross Activity DCGLs". Sr-90 concentrations in sediment and soil were ascertained by direct analysis.Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations that are less than 5%for individual radionuclides and that are less than 10% for the aggregate of all radionuclides that are de-selected.

This process was applied to analysis data for this survey unit.The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 2 area and discrete, elevated areas of contamination were not expected.The Sign Test was selected as the non-parametric statistical test to demonstrate that the null hypothesis was rejected.

The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

In addition, this approach is conservative since it includes background Cs-137 as part of the sample set.The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Samples for Final Revision 0 8 Revision 0 8 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Status Survey. " The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.5 to maintain the relative shift (A/o) in the range of 1 and 3. The resulting relative shift was 2.7. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.This indicates that the survey unit has a high probability of rejecting the null hypothesis, assuming that the characterization data are representative of the FSS results. Survey design specified fifteen (15) sediment core samples for non-parametric statistical testing.The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey. " Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.'TaIbie 3 -apeMeasur~emeiutlocations with Associated GPS Coordinates"-

Designation Northing -Easting 9106-0006-001F 235490.83 671656.84 9106-0006-003F 235412.87 671611.83 9106-0006-004F 235412.87 671701.85 9106-0006-005F 235412.87 671791.88 9106-0006-006F 235412.87 671881.90 9106-0006-007F 235334.91 671746.86 9106-0006-008F 235334.91 671836.89 9106-0006-009F 235334.91 671926.91 9106-0006-01 OF 235334.91 672016.94 9106-0006-011 F 235334.91 672106.96 9106-0006-012F 235334.91 672196.99 9106-0006-014F 235256.94 672061.95 9106-0006-015F 235256.94 672151.98 9106-0006-017F 235206.44 672120.54 9106-0006-018F 235420.43 671845.27 9106-0006-019F 235364.94 671732.17 9106-0006-020F 235253.59 672053.62 Revision 0 9 Revision 0 9 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD The sample location designations of Table 3 are not sequentially inclusive because of the necessity to relocate some samples due to the inaccessibility of the original sample locations.

Grid Sample locations 9106-0006-002F and 9106-0006-013F were found to be on dry land. This was also the case for biased sample location 9106-0006-16F.

Consequently, the grid sample locations were randomly re-located using the VSP software to two (2) new locations designated as 9106-0006-019F and 9106-0006-020F.

Biased sample 9106-0006-016F was relocated to location 9106-0006-018F, a location that also was in the vicinity of the outfall that was of interest.Three (3) sediment samples were analyzed for the full suite of radionuclides specified in Table 1, exceeding the requirement to analyze 5% of the sample population for HTD analysis specified in procedure RPM 5.1-11. Two (2)samples were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RAND" functions.

In addition, the two (2) samples, which were determined to contribute the greatest dose based on gamma only analyses, were also selected for HTD analyses.

Coincidentally, one of these (sample 9106-0006-010F) was selected in the earlier random selections, so only one additional sample was analyzed based on the gamma results The implementation of survey specific quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey, " included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory.

These locations were selected randomly using the Microsoft Excel "RAND" function.

The number of quality control samples exceeded the 5% requirement.

The LTP specifies that scanning is not required for the FSS of the Discharge Canal. Table 4 provides a synopsis of the survey design.Revision 0 10 Revision 0 10 DISCHARGE CANAL SURVEY UNIT 9 106-0006 RELEASE RECORD survey unit Land Area 9,716 m 2 Based on AutoCAD-LT and Visual Sample Plan calculations Type I and Type 2 errors were 0.05, Number of 15 sigma was 0.183 the LBGR was set to 0.5 Measurements to maintain Relative Shift in the range of I and 3, Relative Shift was 2.7 Grid Spacing 27.4 m Based on triangular grid 3.16 pCi/g Cs-137 Design DCGL 1.52 pCi/g Co-60 To achieve ten (10) mrem/yr TEDE 0.62 pCi/g Sr-90 Operational 6.01 pCi/g Cs-137 To achieve nineteen (19) mrem/yr DCol 2.90 pCi/g Co-60 TEDE (2) to demonstrate compliance with DCGL 1.18 pCi/g Sr-90 Equation 2 of this Release Record Scan Coverage N/A The LTP exempts this area Sediment 6.01 pCi/g Cs-137 The Operational DCGL meets the LTP Investigation 2.90 pCi/g Co-60 criteria for a Class 2 survey unit Level 1.18 pCi/g Sr-90 (1) The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 as the total dose from existing and future groundwater had not been established at the time of planning the FSS (2) The allowable dose for soil in this survey unit is nineteen (19) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0021.

The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.Measurement locations were identified in North American Datum (NAD) 1927 coordinates that were supplied to the sampling vendor, Ocean Surveys, Inc.(OSI) of Old Saybrook, Connecticut.

Discharge Canal sampling was accomplished using direct push technology to collect composite samples of bottom and mean high water mark sediments.

Sediment cores from the Discharge Canal were obtained by OSI using a vibrating corer that is platform mounted on a sampling vessel. The core barrel was a three (3) inch diameter thin-walled aluminum tube which also served as a core liner (ten (10) feet or less). A core catcher was available to prevent the sample from sliding out of the bottom of the tube. Vessel positioning and the determination of sample Revision 0 I1I Revision 0 11 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD locations were accomplished using a GPS interfaced with a navigation and data logging system.After extraction, water was drained from above the sample by drilling holes above the sediment.

The liner was cut, capped, sealed, labeled and turned over to site personnel who processed and controlled the samples under Chain of Custody (COC) protocols in accordance with procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples. " Rinsing of the barrel and associated equipment was performed between sampling events. New aluminum tubes were used for each sample to prevent cross-contamination of subsequent samples.The fifteen (15) sediment samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using COC protocols.

Three (3) samples (9106-0006-005F, 9106-0006-009F and 9106-0006-010F) were selected for HTD radionuclide analysis by the off-site laboratory The implementation of quality control measures included the collection of two (2) split samples at locations 9106-0006-007F and 9106-0006-018F for "split sample" analysis by the off-site laboratory.

6. SURVEY RESULTS The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL) -Charleston, South Carolina.

The laboratory analyzed the fifteen (15) samples taken for non-parametric statistical testing and the associated duplicates using gamma spectroscopy.

Sr-90 was analyzed by gas flow proportional counting.

All analyses were performed to the required MDC.Cesium-137 was identified in ten (10), Co-60 was identified in nine (9) and Sr-90 in one (1) of the fifteen (15) samples.Several other radionuclides which were positively identified (i.e., a result greater than two (2) standard deviations uncertainty) could be de-selected or excluded using the 5% and 10% rule described in Section 5.4.7.2 of the LTP.The off-site laboratory also processed three (3) samples for full HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy and liquid scintillation depending upon the radionuclide and the measurement method. All analyses were performed to the required MDC. Two (2) of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one (1)Revision 0 12 Revision 0 12 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD sample; however, each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules.None of the sample results exceeded the Operational DCGL or required further investigation.

A summary of the sample results is provided in Table 5.____ Table 5-. Sum mary of S~oil Sampleh Reut a m11pl e Cs-1~37 Co!-60() sr9 Fric~tion of the:::::Operational:

O Number~~ pc!g~ p 'lg Cilg prto-At((I 9106-0006-001 F -7.55E-04

-3.31 E-03 5.3 7E-04 -8.12E-04 9106-0006-003F 1.70E-01 7.22E-01 1.45E-02 2.90E-01 9106-0006-004F 9.60E-02 4.38E-02 4.27E-03 3.47E-02 9106-0006-005F 4.09E-0 I 1.94E+00 1.95E-02 7.54E-0 I 9106-0006-006F 1.30E-01 2.41 E-01 7.50E-04 1.05E-01 9106-0006-007F 1.38E-02 1.58E-02 -1 .OOE-02 -7.30E-04 9106-0006-008F 2.95E-01 6.35E-01 4.02E-03 2.71 E-01 9106-0006-009F 2.26E-01 1.02E-0 I 7.88E-03 7.95E-02 9106-0006-01 OF 5.20E-01 6.3 1E-01 7.15E-03 3.1 0E-O1 9106-0006-01 IF 3.12E-03 4.70E-02 1.49E-02 2.94E-02 9106-0006-012F 2.71 E-02 6.08E-03 -2.02E-03 4.89E-03 9106-0006-014F 1.79E-01 4.86E-0 1 -1.04E-03 1.96E-01 9106-0006-015F 3.43E-01 2.21E-01 -3.81E-03 1.30E-01 9106-0006-01 9F -2.82E-02

-1.34E-02 1.67E-03 -7.90E-03 9106-0006-020F 1.28E-02 7.34E-02 -5.59E-03 2.27E-02 (1) The Operational DCGLs from Table 2 are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 1.18 for Sr-90; these are used in conjunction with the unity rule to achieve 19 mrem/yr TEDE (2) These values represent only the identified radionuclides Two (2) biased samples were required by the sample plan. These samples were designated as sample locations 9106-0006-017F and 9106-0006-018F.

The sample results are presented in Table 6 below.9106-0006-017F 2.34E-02 1.44E-02 9106-0006-018F 5.69E-02 1.20E-01 6.14E-03 5.27E-02 2.23E-03 I (1) The Operational DCGLs from Table 2 are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 1.18 for Sr-90; these are used in conjunction with the unity rule to achieve nineteen (19)mrem/yr TEDE 7. QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis.

Two (2) of the samples were selected for analysis, which Revision 0 13 Revision 0 13 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 and as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey. " For one (1) of the split-sample comparisons (9106-0005-01 8F/S), Cs- 137 was found to not meet the comparison criterion; however, this nuclide may not be present in a particulate form and, therefore, is not necessarily an indicator of a non-homogenous mixing of the soil matrix. K-40, a natural radioisotope, was also found not to be present at an acceptable level of agreement, so the comparison issue was dispositioned to the Condition Report (CR) process, to resolve the issue. The issue is not believed to affect the outcome of the FSS for the following reasons:* The other quality control split sample comparison (9106-0006-007F/S) was found to meet the agreement criteria." The balance of quality control samples for the discharge canal area numbering some thirty-six (36) samples were found to be in acceptable agreement." The sediment samples were found to be at approximately fifteen (15)percent of the nineteen (19) mrem/yr DCGL.The sample analysis vendor, General Engineering Laboratories (GEL) -Charleston, South Carolina, maintained quality control and quality assurance plans as part of normal operation.

Refer to Attachment 2 for data and data quality analysis results.8. INVESTIGATIONS AND RESULTS One (1) sample result was found to exceed the design DCGL, but was below the nineteen (19) mrem/yr operational DCGL, as specified in Table 4. Confirmatory samples were collected to determine the extent of contamination.

The area extent was bounded by taking four (4) confirmatory samples, one (1) in each direction of the compass, two (2) meters distant from the elevated sample location.

The gamma spectroscopy and Sr-90 results are included in Table 10.005F 005B 1.14E-01 4.36E-01 5.01E-03 1.94E-01 005C 3.17E-01 8.21E-01 7.38E-03 3.83E-01 005D 1.03E-01 1.48E-01 4.46E-04 7.67E-02 (1) The Operational DCGLs from Table 2 are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 1.18 for Sr-90; these are used in conjunction with the unity rule to achieve nineteen (19) mrem/yr TEDE Revision 0 14 Revision 0 14 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD The confirmatory results demonstrate that no measurements exceed the nineteen (19) mrem/yr operational DCGL, indicating that no further actions are warranted.

9. REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.10. CHANGES FROM THE FINAL STATUS SURVEY PLAN The survey was designed to ten (10) mrem/yr TEDE which was conservative and necessary at the time of FSS planning.

It is no longer required as the total dose from existing and future groundwater has been established.

The dose for soil used to demonstrate compliance with the LTP criteria is nineteen (19)mrem/yr TEDE as discussed in Section 2 of this Release Record.11. DATA QUALITY ASSESSMENT (DQA)The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The Sign Test shows that the survey unit passes FSS.Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation).

The sample standard deviation was slightly more than the value used for the survey design. This is represented by the shift in the retrospective power curve as shown in Attachment 2f. This would indicate a change to the original LBGR to maintain the number of samples at fifteen (15) to meet the Operational DCGL. However, the value of LBGR is less of a critical issue as the survey unit has passed the statistical test, and the mean and median values are well below the Operational DCGL when used in conjunction with the unity rule.Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the release criteria with adequate power as required by the DQOs.Revision 0 15 Revision 0 15 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD The range of the data, about 3.8 standard deviations, was not unusually large.The difference between the mean and median was 34% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows some positive skewness as confirmed by the calculated skew of 2.14.All data, assessments, and graphical representations are provided in Attachment 2.12. ANOMALIES The anomalies associate with the disagreement between the field splits at sample location (9106-0006-018F) has been discussed in Section 7. The issue was referred to Condition Report (CR-06-0223).

No other anomalies were identified for this survey unit.13. CONCLUSIONS Survey Unit 9106-0006 has met the final DQOs of the FSS. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved.

Elevated Measurement Comparison and remediation was not required.The sample data passed the Sign Test. The null hypothesis was rejected.Graphical representation of data indicates some positive skewness that is probably due to localized differences in particulate deposition rates, hydraulic velocity and sedimentation rates. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved.

The survey unit was properly designated as Class 2.The dose contribution from sediment is 2.8 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.This survey unit is not affected by existing groundwater (reference CY memo ISC 06-024). It has been determined that the dose contribution from existing groundwater sources is bounded by zero (0) mrem/yr TEDE.This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.The average total dose from residual radioactivity in this survey unit, including that from sediment, will not exceed 2.8 mrem/yr Total Effective Dose Equivalent (TEDE).Revision 0 16 Revision 0 16 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD 14. ATTACHMENTS 14.1 Attachment 1 -Figures 14.2 Attachment 2 -Sample and Statistical Data Revision 0 17 Revision 0 17 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 1 Figures (5 pages)

-Wa -%I/-Skme wall 0 70 140-Feet ComdiMN aM in NAD27CbGf~

Connecticut Yankee Atomic Power Company Date By Rev.Site Map with Reference to Survey Unit 9106-0006

^1 71 e 1 0 14-0 70 140 Fedt 7onnecticut River Connecicut Yankee Atomic Power Company Date By Rev.9106-000 Final Staus Survey Design fl#- I7ul V 0 0

qa-P~d 0.014 Wetfra-0.03 -S&bMn 1.02-0.001

-0.00SqLmw 0 0700 1409 &M*OCU ,ýB (0 005) 00056 5106-00490 6 00 FialSttu ureyDeig Oter206 Stronium-0 PotingPlotI E.NSOW DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2 Sample and Statistical Data DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2a Sample Data (253Pages)

Table of Contents General Narrative

................................

1 Chain of Custody and Supporting Documentation

...........

4 Radiological A nalysis ..........................................................

11 Sam ple Data Sum m ary ......................................................

31 Q uality C ontrol D ata ...........................................................

73 General Narrative 1 CASE NARRATIVE For CONNECTICUT YANKEE RE: Sediment PO# 002332 Work Order: 162850 SDG: MSR #06-0687 June 7, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on May 12, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample 1D 162850001 162850002 162850003 162850004 162850005 162850006 162850007 162850008 Client Sample ID 9106-0006-01 IF 9106-0006-014F 9106-0006-015F 9106-0006-018F 9106-0006-018FS 9106-0006-019F 9106-0006-OO1F 9106-0006-003F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712 -Charleston, SC 29417 -2040 Savage Road (29407)Phone (843) 556-8171 ° Fa2(843) 766-1178

  • www.gel.com Sample ID 162850009 162850010 162850011 162850012 162850013 162850014 162850015 162850016 162850017 162850018 162850019 Client Sample ID 9106-0006-008F 9106-0006-009F 9106-0006-01OF 9106-0006-020F 9106-0006-004F 9106-0006-005F 9106-0006-006F 9106-0006-007F 9106-0006-007FS 9106-0006-012F 9106-0006-017F Items of Note: There are no items of note.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Seventeen sediment samples were analyzed for FSSGAM and Sr-90.Two sediment samples were analyzed for FSSALL.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Packagee: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)Phone (843) 556-8171
  • Fa3(843) 766-1178
  • www.gel.com Chain of Custody and Supporting Documentation 4

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major HelhPyis rcdr P-GG-510-03Atcmn -C-01Mjo Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 Name: Haddam Neck Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

Z 301D. [F 14 D. [] 7 D.Samples Shipped Via:[ Fed Ex E UPS E1 Hand nI Other Bill of Lading #7cf2O0- 5clgo -6 5T-Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 Project Name: Haddam Neck Decommissic Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

Z 30 D. E] 14 D. [] 7 D.)le Z LTP QA El Radwaste QA [] Non QA Samples Shipped Via: Z Fed Ex LI UPS LI Hand Date/Time LI Other Bill of Lading #f 712 7*to- 4 611 Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00332 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lah,,Use Only",, Contact Name & Phone: C rnom ents: ! ..Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 <'843 556 8171. Attn. Cheryl Jones " Priority:

[ 30 D. [ 14 D, E 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Saple. 1.9106-0006-004F 4/28/06 12:46 SE C BP x x Transferred from COC 2006-00317 9106-0006-005F 4/28/06 13:03 SE C BP x x Transferred from COC 2006-00317 9106-0006-006F 4/28/06 13:22 SE C BP X X Transferred from COC 2006-00317 9106-0006-007F 4/28/06 13:41 SE C BP x x Transferred from COC 2006-00317 9106-0006-007FS 4/28/06 13:41 SE C BP x x Transferred from COC 2006-00317 9106-0006-012F 5/01/06 13:40 SE C BP x x Transferred from COC 2006-00317 9106-0006-017F 5/01/06 14:03 SE C BP x X Transferred from COC 2006-00317

--:.' '.: : NOTES: PO #: 002332 MSR #: 06-C41 SSWP# NA Z LTP QA E1 Radwaste QA[I Non QA 1) Relinquished By Date/Time

2) Received By ate/Time 3) Relinquished By Date/Time
4) Received By bate/Time Samples Shipped Via: Z Fed Ex El uPs[] Hand E] Other Bill of Lading #Iberna Container T~mpif'Deg.~y Sealed?custlboy sealIntact., y,
  • N, 2 .%:

Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-OO1 Figure 1. Sample Check-in List.Date/rime Received':

CI @Yi7 (-)SDG#: AA ,, o (o--h Work Order Number: / --." ShippingCcftitainerID (OID+/- ,2Lt Chainof Custody# .S ' CO vi(' StKfe -(.1. Custody Seals oxi shipping container intact? -Yes [ No 2. Custody Seals dated and signed? Yes[ ].No 3. Chain-of-Custody record present? Yes(P)No I I 4. Cooler temperature .oc_.5. .Vermiculite/packing materials is: Wet Dr Dry (,* 6. t .~L (OvZ ...6. -,";Number of samples in shipping Container:.

4u.-.. ..'Qf', nyýf-. .7. Sample holding times exceeded?

Yes[]No -8. Samples have:-~tape hazard labels* 2custody seals --.appropriate sample labels 9. Samples are:good condition -leaking

"" have ir bubbles 10. Were any anomalies identified in sample receipt? Yes [] No .11" * .Description of.anomalies (include sample numbe. .. 'Sample. CustodianlLaboratory:

.... ...Le- r; ..Data Telephoned to:______________________

., .* -.~ o n1__ ._ _,__. ..._. ... .1 4 -'." / " ..*8 SAMPLE RECEIPT & REVIEW FORM 0 ýs%'NTORIV'3 P M use onl Client: Cý n IVfl 1 SDG/ARCOC/Work Order: /C z3Z-, /(.,,ZT5 Date Received:

97/ PM(A) Review (oture mo-eoulltnI are resolved prior to siping): Received By: C lAev I c k Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items)I Shipping containers received intact ircil Applicable:

seals broken damaged container leaking container other (describe) 1and sealed? -;Samples requiring cold / Circle Coolant I ice bags blue ice dry ice other describe)2 preservation within (4 +/ 2 C)?Record preservation method. 0 C_3 Chain of custody documents C-0 OU o-xi Ct VU- e" included with shipment?V Sample containers intact and 1 alb cn damaged container k-aing container 1 sealed? tu-" ircppablesalbkci

-5 Samples requiring chemical Sample ID's. containers affected and observed pH: 5 reservation at proper pH?6 VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory) 1 8 Samples received within holding Id's and tests affeacd: time? ______________________________

9 Sample ID's on COC match ID's Sample ID's and containers affected: on bottles? I 0 Date & time on COC match date Sample ID's affected:& time on bottles? I Number of containers received Sample ID's affected: match number indicated on COC?COC form is properly signed in l , r Ct)G. "4iL, YCULC 1i , .s C1 2 relinquished/received sections?

  • Air Bill ,Tracking
  1. 's, & , Ccv(U"- I ux.-c (- Additional Comments>- RSORADReceipt_
  1. U *If > x2 area background is observed on samples identified as "non-Suispected Hazard Information 5-=S e H rm regulated/non-radioactive", contact the Radiation Safety group for further__ __ FZ investigation.

Radiological Classification?

Maximum Counts Observed*:

PCB Regulated?

V Comments: Shipped as IX) 1Hazardous

  • Material?

If yes, contact Waste "/ Hazard Class Shipped: M Manager or ESH Manager.PM (or PMA) review of Hazard classification:

Initials Date: a 9 SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM-F.ed F, o- kO: C00- con4=0.t, (p(tr)(r, 105 A Loi5S 00,336 C (o0) s,( Y 4l 5 7oýýl-.v hatd n..bUsfc Ed 15 a i~ '"c_fm) w Alu 3.J+'v "~ c~ _ __ _ __J_ _10 RADIOLOGICAL ANALYSIS 11 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 162850 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS DOE EML HASL-300, Am-05-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 533471 529740 529739 Sample ID 162850010 162850011 1201101117 1201101118 1201101119 1201101120 Client ID 9106-0006-009F 9106-0006-01 OF Method Blank (MB)162485017(9106-0005-005F)

Sample Duplicate (DUP)162485017(9106-0005-005F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

12 Ouality Control (00 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162485017 (9106-0005-005F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 13 Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 533472 529740 529739 Sample ID 162850010 162850011 1201101121 1201101122 1201101123 1201101124 Client ID 9106-0006-009F 9106-0006-01 OF Method Blank (MB)162485017(9106-0005-005F)

Sample Duplicate (DUP)162485017(9106-0005-005F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (OC Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162485017 (9106-0005-005F).

QC Information All of the QC samples met the required acceptance limits.14 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 533473 Prep Batch Number: 529740 Dry Soil Prep GL-RAD-A-021 Batch Number: 529739 15 Sample ID Client ID 162850010 9106-0006-009F 162850011 9106-0006-OIOF 1201101125 Method Blank (MB)1201101126 162485017(9106-0005-005F)

Sample Duplicate (DUP)1201101127 162485017(9106-0005-005F)

Matrix Spike (MS)1201101128 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162485017 (9106-0005-005F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis The tracer yield for sample 1201101127 (9106-0005-005F) was recounted due to poor resolution.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 16 referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Oualifier information Manual qualifiers were not required.Method/Analysis Information Product: Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Gamma,Solid-FSS GAM & ALL FSS EML HASL 300, 4.5.2.3 Dry Soil Prep 529777 529739 17 Sample ID 162850001 162850002 162850003 162850004 162850005 162850006 162850007 162850008 162850009 162850010 162850011 162850012 162850013 162850014 162850015 162850016 162850017 162850018 162850019 1201092335 1201092336 1201092337 Client ID 9106-0006-01 IF 9106-0006-014F 9106-0006-015F 9106-0006-018F 9106-0006-018FS 9106-0006-019F 9106-0006-001F 9106-0006-003F 9106-0006-008F 9106-0006-009F 9106-0006-01 OF 9106-0006-020F 9106-0006-004F 9106-0006-005F 9106-0006-006F 9106-0006-007F 9106-0006-007FS 9106-0006-012F 9106-0006-017F Method Blank (MB)162850001(9106-0006-011 F) Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162850001 (9106-0006-01 IF).QC Information 18 All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments The sample and the duplicate did not meet the relative percent difference requirement for Bi-212, Ra-226 and Th-208, however they do meet the relative error ratio requirement with value of 2.26 for Bi-212, 1.99 for Ra-226 and 2.72 for Th-208.Qualifier information 19 Qualifier UI Reason Data rejected due to interference.

Analyte Europium-155 UI Manganese-54 Data rejected due to low abundance.

Bismuth-214 Cesium- 134 Sample 162850007 162850009 162850014 162850016 162850017 162850017 1201092336 162850004 162850005 162850006 162850007 162850009 162850012 162850013 162850015 162850016 162850017 162850019 1201092336 Method/Analysis Information Product: Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: GFPC, Sr90, solid-ALL FSS EPA 905.0 Modified Ash Soil Prep Dry Soil Prep 534447 529740 529739 20 Sample ID 162850001 162850002 162850003 162850004 162850005 162850006 162850007 162850008 162850009 162850010 162850011 162850012 162850013 162850014 162850015 162850016 162850017 162850018 162850019 1201103430 1201103431 1201103432 1201103433 Client ID 9106-0006-01 IF 9106-0006-014F 9106-0006-015F 9106-0006-018F 9106-0006-018FS 9106-0006-019F 9106-0006-001F 9106-0006-003F 9106-0006-008F 9106-0006-009F 9106-0006-OIOF 9106-0006-020F 9106-0006-004F 9106-0006-005F 9106-0006-006F 9106-0006-007F 9106-0006-007FS 9106-0006-012F 9106-0006-017F Method Blank (MB)162850003(9106-0006-015F)

Sample Duplicate (DUP)162850003(9106-0006-015F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC 21 The following sample was used for QC: 162850003 (9106-0006-015F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 162850010 (9106-0006-009F) and 162850011 (9106-0006-010F) were recounted due to high MDAs. Sample 1201103433 (LCS) was recounted due to low/high recovery.Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments The blank, 1201103430 (MB), did not meet the detection limit due to keeping the blank volume consistent with the other sample aliquots.

All other samples met the detection limits.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 531704 22 Sample ID Client ID 162850010 9106-0006-009F 162850011 9106-0006-OIOF 1201096867 Method Blank (MB)1201096868 162583001(NOL-02-02-005-F-S)

Sample Duplicate (DUP)1201096869 162583001(NOL-02-02-005-F-S)

Matrix Spike (MS)1201096870 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162583001 (NOL-02-02-005-F-S).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 23 referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 531618 529740 529739 Sample ID 162850010 162850011 1201096631 1201096632 1201096633 1201096634 Client ID 9106-0006-009F 9106-0006-01 OF Method Blank (MB)163173001 (9304-0000-063RACR)

Sample Duplicate (DUP)163173001(9304-0000-063RACR)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry 24 All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 163173001 (9304-0000-063RACR).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 25 Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: Prep Method: DOE RESL Ni-1, Modified Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 531622 529740 529739 Sample ID 162850010 162850011 1201096644 1201096645 1201096646 1201096647 Client ID 9106-0006-009F 9106-0006-01 OF Method Blank (MB)163173001 (9304-0000-063RACR)

Sample Duplicate (DUP)163173001(9304-0000-063RACR)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 163173001 (9304-0000-063RACR).

QC Information All of the QC samples met the required acceptance limits.26 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: LSC, Tritium Dist, Solid -1 to 2 pCi/g Analytical Method: EPA 906.0 Modified Analytical Batch Number: 531705 Sample ID 162850010 162850011 1201096877 1201096878 1201096879 1201096880 Client ID 9106-0006-009F 9106-0006-01OF Method Blank (MB)162583001(NOL-02-02-005-F-S)

Sample Duplicate (DUP)162583001(NOL-02-02-005-F-S)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 11.27 Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162583001 (NOL-02-02-005-F-S).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 1201096877 (MB), 162850010 (9106-0006-009F) and 162850011 (9106-0006-01OF) were recounted due to high MDAs.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 28 Product: Liquid Scint C14, Solid AII,FSS EPA EERF C-01 Modified Analytical Method: Analytical Batch Number: 534984 Sample ID 162850010 162850011 1201104745 1201104746 1201104747 1201104748 Client ID 9106-0006-009F 9106-0006-01OF Method Blank (MB)163173001 (9304-0000-063RACR)

Sample Duplicate (DUP)163173001 (9304-0000-063RACR)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 163173001 (9304-0000-063RACR).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.29 Sample Re-prep/Re-analysis Samples were reprepped due to low/high recovery.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

1gL 4ie1--30 SAMPLE DATA

SUMMARY

31 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-0687 GEL Work Order: 162850 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.ND The analyte concentration is not detected above the reporting limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 32 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-01 IF 162850001 SE 01-MAY-06 12-MAY-06 Client 42.1%Proiect: YANK01204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-2 4 1 U Bismuth-212 U Bismuth-214 Cesium-134 U Cesium-137 U Cobalt-60 U Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U-0 Potassium-40 Radium-226 Silver-108ni U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.908-0.0354 0.292 0.606 0.0697 0.00312 0.047 0.0184-0.039 0.0871 0.878 0.438 0.029 1.000518 16.0 0.606-0.0164 0.422+/-0.297+/-0.0542+/-0.518+/-0.164+/-0.0502+/-0.0432+/-0.0461+/-0.100+/-0.132+/-0.0891+/-0.106+/-0.111+/-0.0728+/-0.0403+/-1.34+/-0.164+/-0.0372+/-0.0918 0.130 0.0432 0.297 0.0639 0.0444 0.0361 0.0412 0.0827 0.108 0.0735 0.0522 0.0614 0.039 0.0333 0.318 0.0639 0.0294 0.0358+/-0.297+/-0.0542+/-0.518+/-0.164+/-0.0502+/-0.0432+/-0.0461+/-0.100+/-0.132+/-0.0891+/-0.106+/-0.111+/-0.0728+/-0.0403+/- 1.34+/-0.164+/-0.0372+/-0.0918 0.273 0.0886 0.620 0.133 0.0927 0.0754 0.0875 0.171 0.229 0.151 0.107 0.127 0.0816 0.0696 0.686 0.133 0.0611 0.0747 0.0128 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/05/06 2340 529777 1 BXF1 06/02/06 2018 534447 2 0.00244 +/-0.00747 0.00618 +/-0.00747 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0853 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified 33 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-OIF Project: YANK01204 Sample ID: 162850001 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 74 (25%/-,125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.34 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-014F 162850002 SE 01-MAY-06 12-MAY-06 Client 31%Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 1.02 Americium-241 U 0.0071 Bismuth-212 1.12 Bismuth-214 0.548 Cesium-134 U 0.0645 Cesium-137 0.179 Cobalt-60 0.486 Europium-152 U 0.00309 Europium-154 U 0.0957 Europium-155 U 0.00678 Lead-212 0.568 Lead-214 0.767 Manganese-54 U -0.0368 Niobium-94 U 0.0384 Potassium-40 12.9 Radium-226 0.548 Silver-108m U -0.00315 Thallium-208 0.249 Rad Gas Flow Proportional Counting+/-0.295+/-0.136+/-0.502+/-0.173+/-0.0518+/-0.0779+/-0.119+/-0.142+/-0.139+/-0.105+1-0.151+/-0.176+/-0.046+/-0.0389+/-1.66+/-0.173+/-0.0373+/-0.0836 0.127 0.0958 0.248 0.0714 0.0479 0.0345 0.0396 0.0883 0.124 0.0839 0.0586 0.0653 0.0349 0.0353 0.282 0.0714 0.0302 0.0351+/-0.295+/-0.136+/-0.502+/-0.173+/-0.0518+/-0.0779+/-0.119+/-0.142+/-0.139+/-0.105+/-0.151+/-0.176+/-0.046+/-0.0389+/-1.66+/-0.173+/-0.0373+/-0.0836 0.254 0.192 0.496 0.143 0.0957 0.0689 0.0791 0.177 0.248 0.168 0.117 0.131 0.0698 0.0705 0.564 0.143 0.0603 0.0702 0.0105 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/05/06 1716 529777 1 GFPC, Sr9O, solid-ALL FSS Strontium-90 U -0.00104 +/-0.00595 0.00504 +/-0.00595 BXF1 06/02/06 2018 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 LXM2 05/15/06 0854 529740 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 35 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-014F Proiect: YANK01204 Sample ID: 162850002 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 84 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.36 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analv-id Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-015F 162850003 SE 01-MAY-06 12-MAY-06 Client 20.2%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U -Europium-155 U Lead-212 Lead-214 Manganese-54 U-C Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U -0.650 0.0935 0.475 0.435 0.0461 0.343 0.221-0.0894-0.00226 0.0459 0.650 0.500 1.000117-0.0154 10.6 0.435 0.00346 0.223+/-0.227+/-0.109+/-0.429+/-0.114+/-0.0384+/-0.0587+/-0.0669+/-0.0921+/-0.0861+/-0.0737+/-0.0936+/-0.121+/-0.0312+/-0.029+/-1.19+/-0.114+/-0.0254+/-0.0637 0.0899 0.091 0.155 0.0453 0.0306 0.0222 0.0215 0.054 0.0725 0.0674 0.0352 0.0424 0.0235 0.0208 0.199 0.0453 0.0213 0.0243+/-0.227+/-0.109+/-0.429+/-0.114+/-0.0384+/-0.0587+/-0.0669+/-0.0921+/-0.0861+/-0.0737+/-0.0936+/-0.121+/-0.0312+/-0.029+/-1.19+/-0.114+/-0.0254+/-0.0637 0.180 0.182 0.309 0.0905 0.0611 0.0444 0.0429 0.108 0.145 0.135 0.0703 0.0848 0.0469 0.0416 0.398 0.0905 0.0426 0.0485 0.0113 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/05/06 1716 529777 1 BXF1 06/02/06 2018 534447 2 0.00381 +/-0.00625 0.00542 +/-0.00626 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 37 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-015F Proiect: YANK01204 Sample ID: 162850003 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 99 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.38 GENERAL ENGINEERING LABORATORGES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-018F 162850004 SE 01-MAY-06 12-MAY-06 Client 21.4%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 UUI Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U -Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 1.49-0.0253 0.829 0.901 0.00 0.0569 0.120 0.0162 0.0154 0.0679 1.58 1.06 0.0075-0.0096 I 17.4 0.901 0.00355 0.529+/-0.159+/-0.103+/-0.238+/-0.086+/-0.0254+/-0.0266+/-0.0383+/-0.0445+/-0.0549+/-0.0806+/-0.0659+/-0.0843+/-0.0214+/-0.0163+/-0.786+/-0.086+/-0.0145+/-0.043 0.0473 0.0885 0.110 0.028 0.0201 0.0162 0.0138 0.0407 0.0466 0.0521 0.024 0.0272 0.0134 0.0132 0.133 0.028 0.013 0.0139+/-0.159+/-0.103+/-0.238+/-0.086+/-0.0254+/-0.0266+/-0.0383+/-0.0445+/-0.0549+/-0.0806+/-0.0659+/-0.0843+/-0.0214+/-0.0163+/-0.786+/-0.086+/-0.0145+/-0.043 0.0996 0.182 0.231 0.0582 0.0417 0.0336 0.0294 0.084 0.0982 0.107 0.0494 0.0564 0.0282 0.0275 0.284 0.0582 0.0269 0.029 0.0148 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/05/06 1918 529777 1 BXF1 06/02/06 2018 534447 2 0.00223 +/-0.00863 0.00716 +/-0.00863 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 39 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-018F Project: YANKO 1204 Sample ID: 162850004 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 86 (25%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.40 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-018FS 162850005 SE 01-MAY-06 12-MAY-06 Client 16.8%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 1.50 Americium-241 U 0.0164 Bismuth-212 1.06 Bismuth-214 0.811 Cesium-134 UUI 0.00 Cesium-137 U 0.0247 Cobalt-60 0.0993 Europium-152 U 0.0167 Europium-154 U -0.0286 Europium-155 U 0.00 Lead-212 1.33 Lead-214 1.03 Manganese-54 U 0.0176 Niobium-94 U -0.00731 Potassium-40 11.3 Radium-226 0.811 Silver-108m U 0.0175 Thallium-208 0.467 Rad Gas Flow Proportional Counting+/-0.193+/-0.0929+/-0.269+/-0.0973+/-0.0365+/-0.023+/-0.0313+/-0.0526+/-0.0637+/-0.0557+/-0.0744+/-0.107+/-0.0296+/-0.0193+/-0.853+/-0.0973+/-0.0179+/-0.0504 0.0586 0.0802 0.130 0.0345 0.0256 0.0183 0.0164 0.0474 0.0524 0.053 0.0276 0.0316 0.0187 0.0165 0.149 0.0345 0.0163 0.0178+/-0.193+/-0.0929+/-0.269+/-0.0973+/-0.0365+/-0.023+/-0.0313+/-0.0526+/-0.0637+/-0.0557+/-0.0744+/-0.107+/-0.0296+/-0.0193+/-0.853+/-0.0973+/-0.0179+1-0.0504 0.124 0.164 0.273 0.0719 0.0532 0.0384 0.0354 0.098 0.112 0.108 0.0568 0.0656 0.0392 0.0345 0.325 0.0719 0.0338 0.0372 0.0129 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/07/06 1941 529777 1 GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.00318 +/-0.0075 0.00614 +/-0.0075 BXFI 06/02/062018 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-0211B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 41 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-018FS Project: YANK01204 Sample ID: 162850005 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 79 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.42 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-019F 162850006 SE 01-MAY-06 12-MAY-06 Client 34%Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.743 Americium-241 0.190 Bismuth-212 0.577 Bismuth-214 0.438 Cesium-134 UUI 0.00 Cesium-137 U -0.0282 Cobalt-60 U -0.0134 Europium-152 U -0.106 Europium-154 U -0.0332 Europium-155 U 0.00 Lead-212 0.907 Lead-214 0.546 Manganese-54 U 0.0171 Niobium-94 U 0.0284 Potassium-40 14.5 Radium-226 0.438 Silver-108m U -0.021 Thallium-208 0.291 Rad Gas Flow Proportional Counting+/-0.243+/-0.136+/-0.509+/-0.106+/-0.056+/-0.028+/-0.0294+/-0.0751+/-0.0894+/-0.0752+1-0.115+/-0.133+/-0.0293+/-0.0406+/- 1.48+/-0.106+/-0.0229+/-0.0645 0.0838 0.0836 0.177 0.0462 0.0325 0.0208 0.0227 0.0531 0.0705 0.0641 0.0322 0.0396 0.0245 0.0216 0.227 0.0462 0.0179 0.0219+/-0.243+/-0.136+/-0.509+/-0.106+/-0.056+/-0.028+/-0.0294+/-0.0751+/-0.0894+/-0.0752+/-0.115+/-0.133+/-0.0293+/-0.0406+/-1.48+/-0.106+/-0.0229+/-0.0645 0.180 0.174 0.378 0.0973 0.0685 0.0444 0.0501 0.112 0.154 0.132 0.0669 0.0832 0.0523 0.0458 0.502 0.0973 0.0378 0.0466 0.0121 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/06/06 0018 529777 1 GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00167 +/-0.007 0.00579 +/-0.007 BXFI 06/02/06 2018 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 43 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-019F Project: YANK01204 Sample ID: 162850006 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 84 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.44 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-001F 162850007 SE 28-APR-06 12-MAY-06 Client 22.9%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANKOO Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS Actinium-228 Americium-2 4 1 U Bismuth-212 Bismuth-214 Cesium-134 UUI Cesium-137 U-0 Cobalt-60 U -Europium-152 U -Europium-154 U Europium-155 UUI Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U C 1.47 0.0322 1.38 0.999 0.00 0.000755-0.00331-0.00151 0.0214 0.00 1.43 1.07 0.0269-0.0231 18.5 0.999 0.00689 0.524+/-0.330+1-0.0555+/-0.604+1-0.151+/-0.0794+/-0.039+/-0.0373+/-0.083+/-0.108+/-0.131+/-0.0989+/-0.144+/-0.0563+/-0.0315+/-1.23+/-0.151+/-0.0322+/-0.0835 0.114 0.0457 0.224 0.0546 0.0426 0.0336 0.0313 0.0715 0.093 0.0701 0.0413 0.0506 0.0317 0.0258 0.229 0.0546 0.0276 0.0286+/-0.330+/-0.0555+/-0.604+/-0.151+/-0.0794+/-0.039+/-0.0373+/-0.083+/-0.108+/-0.131+/-0.0989+/-0.144+/-0.0563+/-0.0315+/-1.23+/-0.151+/-0.0322+/-0.0835 0.242 0.0937 0.475 0.115 0.089 0.0705 0.0675 0.149 0.199 0.144 0.0856 0.106 0.0671 0.0545 0.506 0.115 0.0575 0.0603 0.0141 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/07/06 1942 529777 1 BXFI 06/02/06 2018 534447 2.000537 +/-0.00804 0.00672 +/-0.00804 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021 B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 45 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-OO1F Proiect: YANKO 1204 Sample ID: 162850007 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 78 (25%/.-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.46 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-003F 162850008 SE 28-APR-06 12-MAY-06 Client 24.9%Proiect: YANKO 1204 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnna,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 Cobalt-60 Europium-152 U -Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U 0.846-0.0495 0.789 0.475 0.0421 0.170 0.722-0.00848 0.00912 0.0826 0.800 0.619 0.0175 0.0158 12.5 0.475 0.0119 0.304+/-0.189+/-0.0853+/-0.301+/-0.0869+/-0.027+/-0.0418+/-0.0687+/-0.0547+/-0.0708+/-0.0933+/-0.0645+/-0.0893+/-0.026+/-0.0373+/-0.946+/-0.0869+/-0.0191+/-0.0506 0.0734 0.0742 0.153 0.0338 0.0246 0.0201 0.0165 0.0472 0.0597 0.0474 0.0282 0.0349 0.0181 0.017 0.139 0.0338 0.0169 0.0169+/-0.189+/-0.0853+/-0.301+/-0.0869+/-0.027+/-0.0418+/-0.0687+/-0.0547+/-0.0708+/-0.0933+/-0.0645+/-0.0893+/-0.026+/-0.0373+/-0.946+/-0.0869+/-0.0191+/-0.0506 0.156 0.153 0.323 0.0714 0.0517 0.0423 0.0364 0.0985 0.129 0.0979 0.0583 0.0728 0.0386 0.0359 0.312 0.0714 0.0353 0.0358 0.0439 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/07/06 1942 529777 1 BXFI 06/03/06 0903 534447 2 0.0145 +/-0.020 0.0198 +/-0.020 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 47 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-003F Project: YANKO 1204 Sample ID: 162850008 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 79 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.48 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result 9106-0006-008F 162850009 SE 28-APR-06 12-MAY-06 Client 36.9%Proiect: YANK01204 Client ID: YANKOOI Vol. Recv.: Parameter Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actiniumn-228 0.967 Americium-241 U 0.0139 Bismuth-212 0.752 Bismuth-214 0.659 Cesium-134 UUI 0.00 Cesium-137 0.295 Cobalt-60 0.635 Europium-152 U -0.0188 Europiurn-154 U 0.0145 Europium-155 UU1 0.00 Lead-212 1.02 Lead-214 0.812 Manganese-54 U 0.000653 Niobium-94 U 0.00784 Potassium-40 16.9 Radium-226 0.659 Silver-108m U 0.00921 Thallium-208 0.294 Rad Gas Flow Proportional Counting Uncertainty

+/-0.174+/-0.0656+/-0.257+/-0.102+/-0.0255+/-0.0447+/-0.0601+/-0.0427+/-0.0503+/-0.0655+/-0.0932+/-0.105+/-0.018+/-0.0151+/-1.20+/-0.102+/-0.0145+/-0.0457 LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.0502 0.0488 0.110 0.0267 0.0174 0.0133 0.0139 0.0349 0.0415 0.0379 0.0194 0.025 0.015 0.013 0.107 0.0267 0.0121 0.0147+/-0.174+/-0.0656+/-0.257+/-0.102+/-0.0255+/-0.0447+/-0.0601+/-0.0427+/-0.0503+/-0.0655+/-0.0932+/-0.105+/-0.018+/-0.0151+/-1.20+/-0.102+1-0.0145+/-0.0457 0.104 0.0996 0.227 0.0551 0.036 0.0275 0.0293 0.0717 0.087 0.0773 0.0398 0.0514 0.0311 0.0268 0.229 0.0551 0.025 0.0304 0.0388 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/07/06 2201 529777 1 GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00402 +/-0.0162 0.0172 +/-0.0162 BXFI 06/03/06 0904 534447 2 The following Prep Methods were performed Method Description Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description Analyst Date Time Prep Batch MXP2 LXM2 05/15/06 0854 529740 05/14/06 1558 529739 1 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 49 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-008F Proiect: YANKO 1204 Sample ID: 162850009 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 69 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.50 GENERAL ENGINEERING LABORATORIES, LLC.2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-009F 162850010 SE 28-APR-06 12-MAY-06 Client 28.3%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Rad Alpha Spec Analysis Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.03 Curium-2 4 2 U 0.00 Curium-2 4 3/244 U 0.0246 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.015 Plutonium-239/240 U 0.00 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U -1.47 Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.716 Americium-2 4 1 U -0.0471 Bismuth-212 0.609 Bismuth-214 0.393 +Cesium-134 U 0.0223 +Cesium-137 0.226 +Cobalt-60 0.102 +Europium-152 U -0.0219 4 Europium-15 4 U -0.0215 +Europium-155 U 0.0924 -+Lead-212 0.660 +Lead-214 0.545 Manganese-54 U 0.0121 Niobium-94 U 0.00483 4 Potassium-40 11.2 Radium-226 0.393 4 Silver-108m U -0.01 +Thallium-208 0.197 +Rad Gas Flow Proportional Counting GFPC, Sr9 0 , solid -0. 025 pCi/g Strontium-9 0 U 0.00788 +/Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -I to 2 pCi/g Tritium U -0.17+/-0.065/-0.0725/-0.0651+/-0.0648+/-0.0614 0.0367 0.00 0.0368+/-0.065+1-0.0725+/-0.0652 0.161 0.100 0.161 0.186 0.0848 pCi/g pCi/g pCi/g pCi/g pCi/g 0.0505 +/-0.0649 0.00 +/-0.0614+/-7.89 6.69 +/-7.89 13.9 pCi/g+/-0.183+/-0.110+/-0.323/-0.0985/-0.0286/-0.0658/-0.0359/-0.0519/-0.0704/-0.0906/-0.0803+/-0.097+/-0.022-/-0.0185+/-1.20/-0.0985-/-0.0175--0.0465 0.0686 0.0853 0.121 0.0311 0.0231 0.0156 0.0208 0.0425 0.0575 0.0494 0.0262 0.033 0.0194 0.0161 0.154 0.0311 0.015 0.018+/-0.183+/-0.110+/-0.323+/-0.0985+/-0.0286+/-0.0658+/-0.0359+/-0.0519+/-0.0704+/-0.0906+/-0.0803+/-0.097+/-0.022+/-0.0185+/-1.20+/-0.0985+/-0.0175+/-0.0465 0.148 0.177 0.263 0.0666 0.0494 0.0339 0.0458 0.0901 0.126 0.103 0.0548 0.0696 0.0419 0.0346 0.349 0.0666 0.0319 0.0385 0.0208 0.895 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LCW1 05/30/06 1156 533471 1 LCWI 05/30/06 2129 533472 2 LCWI 06/03/06 0646 533473 3 MJHI 06/05/06 2158 529777 4 BXFI 06/05/062116 534447 5 NXPI 06/03/06 0204 531705 6-0.00962 0.00977 +/-0.00962

+/-0.518 0.438 +/-0.518 51 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 tnjun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: 9106-0006-009F 162850010 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAllFSS Carbon-14 U 0.133 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 15.5 Liquid Scint Ni63, Solid ALL FSS Nickel-63 U -4.06 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0504 The following Prep Methods were performed Method Description Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.102 0.0817 +/-0.102 0.169+/-22.8 16.4 +/-22.8 34.4+/-3.35 2.89 +/-3.35 5.89 pCi/g pCi/g pCi/g pCi/g ATH2 06/04/06 0142 534984 7 SLNI 05/29/06 1615 531618 9 SLNI 05/27/06 0221 531622 10 SXEI 05/30/062305 531704 11+/-0.251 0.209 +/-0.251 0.432 Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021 B Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 LXM2 05/15/06 0854 529740 05/14/06 1558 529739 The following Analytical Methods were performed Method Description 1 2 3 4 5 6 7 8 9 10 11 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EML HASL 300, 4.5.2.3 EPA 905.0 Modified EPA 906.0 Modified EPA EERF C-01 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-1, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Test Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid -0.025 pCi/g Liquid Scint Fe55, Solid-ALL FS Recovery%90 74 93 74 83 Acceptable Limits (15%-125%)

(15%-125%)

(25/,-125%)

(25%-/125%)

(15%-125%)

52 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-009F Proiect: YANK01204 Sample ID: 162850010 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 87 (25/,-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.53 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certifieate nf Analwviq................... Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: 9106-0006-010F Proiect: YANK01204 Sample ID: 162850011 Client ID: YANK001 Matrix: SE Vol. Recv.: Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector:

Client Moisture:

28.2%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U Curium-242 U Curium-243/244 U Alphaspec Pu, Solid-ALL FSS Plutonium-238 U Plutonium-239/240 U Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Gamma Spec Analysis 0.0541 0.0217-0.012+/-0.0719+/-0.0576+/-0.0517 0.00 0.0326 0.0402+/-0.0723+/-0.0577+/-0.0517 0.00 +/-0.0691 0.0352 +/-0.069 0.00 +/-0.0691 0.00 +/-0.0692-7.44 +/-7.73 6.81 +/-7.77 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.673 Americium-241 U 0.0697 Bismuth-212 0.401 Bismuth-214 0.472 Cesium-134 U 0.0462 Cesium-137 0.520 Cobalt-60 0.631 Europium-152 U -0.00528 Europium-154 U 0.00414 Europium-155 U 0.00807 Lead-212 0.596 Lead-214 0.541 Manganese-54 U 0.0149 Niobium-94 U 0.00627 Potassium-40 10.1 Radium-226 0.472 Silver-108m U -0.00817 Thallium-208 0.208 Rad Gas Flow Proportional Counting GFPC, Sr90, solid -0. 025 pCi/g Strontitum-90 U 0.00715 +)Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid -I to 2 pCi/g Tritium U 0.118+/-0.182+/-0.0798+/-0.307+/-0.0976+/-0.039+/-0.0547+/-0.0688+/-0.051+/-0.0655+/-0.0505+/-0.0621+/-0.0872+/-0.0228+/-0.0196+/-0.812+/-0.0976+/-0.0 176+/-0.0559 0.0618 0.0686 0.137 0.0323 0.0234 0.0156 0.0167 0.0441 0.0558 0.0451 0.0256 0.0305 0.0201 0.0172 0.149 0.0323 0.0146 0.0168+/-0.182+/-0.0798+/-0.307+/-0.0976+/-0.039+/-0.0547+/-0.0688+1-0.051+/-0.0655+1-0.0505+/-0.0621+/-0.0872+/-0.0228+/-0.0196+/-0.812+/-0.0976+/-0.0176+/-0.0559 0.0675 0.143 0.148 0.0955 0.0955 14.2 0.132 0.141 0.289 0.0679 0.0493 0.0332 0.0365 0.0919 0.120 0.0929 0.0531 0.0637 0.0425 0.0361 0.329 0.0679 0.0306 0.0355 0.0127 0.837 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LCW1 05/30/06 1155 533471 1 LCW1 05/30/06 2129 533472 2 LCW1 06/03/06 0702 533473 3 MJHI 06/06/06 0657 529777 4 BXF1 06/05/06 2117 534447 5 NXPI 06/03/06 0338 531705 6-0.00615 0.00584 +/-0.00616

+/-0.491 0.410 +/-0.491 54 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: 9106-0006-01OF 162850011 Proiect: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAllFSS Carbon-14 U 0.161 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 12.3 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.00 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0163+/-0.109 0.0867 +/-0.109 0.179+/-21.9 .16.0 +/-21.9 33.7+/-4.14 3.47 +/-4.14 7.07+/-0.271 0.227 +/-0.271 0.469 pCi/g pCi/g pCi/g pCi/g ATH2 06/04/06 0345 534984 7 SLNI 05/29/06 1632 531618 9 SLNI 05/27/06 0322 531622 10 SXE1 05/30/062321 531704 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-02e f B Dry Soil Prep Dry Soil Prep GL-RAD-A-021 MXP2 LXM2 05/15/06 0854 529740 05/14/06 1558 529739 The following Analytical Methods were performed Method Description 1 2 3 4 5 6 7 8 9 10 11 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EML HASL 300, 4.5.2.3 EPA 905.0 Modified EPA 906.0 Modified EPA EERF C-01 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-l, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid -0.025 pCi/g Liquid Scint Fe55, Solid-ALL FS Recovery%87 61 94 100 71 Acceptable Limits (15%-125%)

(15%-125%)

(25%/q- 125%)(25%-125%)

(15%-125%)

55 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-OIOF Project: YANK01204 Sample ID: 162850011 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 86 (25%/-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 69 (15%-/125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.56 GENERAL ENGINEERING LABORATORGES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Parameter Qualifier Result 9106-0006-02OF 162850012 SE 01-MAY-06 12-MAY-06 Client 28.9%Project: Client ID: Vol. Recv.: YANKO 1204 YANKOO1 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Ganvma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesiumn-134 UUI Cesium-137 U Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U -Niobium-94 U -Potassium-40 Radium-226 Silver--108m U (Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U -0.844 0.0189 0.614 0.558 0.00 0.0128 0.0734 0.0104 0.0357 0.00 0.809 0.678-0.00567-0.00247 13.8 0.558 0.000505 0.223+/-0.136+/-0.128+/-0.281+/-0.0775+/-0.0331+/-0.0392+/-0.0396+/-0.0537+/-0.0762+/-0.0589+/-0.0588+/-0.0754+/-0.0206+/-0.0182+/-0.850+/-0.0775+/-0.0175+/-0.0431 0.0584 0.0762 0.110 0.0315 0.0228 0.0172 0.0183 0.0461 0.0576 0.0534 0.028 0.0328 0.0172 0.0155 0.143 0.0315 0.0147 0.0165+/-0.136+/-0.128+/-0.281+/-0.0775+/-0.0331+/-0.0392+/-0.0396+/-0.0537+/-0.0762+/-0.0589+/-0.0588+/-0.0754+/-0.0206+/-0.0182+/-0.850+/-0.0775+/-0.0175+/-0.0431 0.125 0.156 0.236 0.0663 0.048 0.0362 0.0395 0.0959 0.124 0.110 0.0577 0.0682 0.0365 0.0328 0.316 0.0663 0.0308 0.0347 0.030 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/06/06 0657 529777 1 BXF1 06/03/06 0904 534447 2-0.00559 +/-0.0104 0.0131 +/-0.0104 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 57 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-020F Project: YANKO 1204 Sample ID: 162850012 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 94 (25 %-125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.58 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-004F 162850013 SE 28-APR-06 12-MAY-06 Client 26%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GanimaSolid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 UUI Cesium-137 Cobalt-60 U Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U 0.972 0.00641 0.604 0.723 0.00 0.096 0.0438-0.0561-0.0703 0.00 0.912 0.716 0.00792 0.00282 11.5 0.723-0.0131 0.300+/-0.265+/-0.0402+/-0.395+/-0.124+/-0.0507+/-0.057+/-0.0445+/-0.0636+/-0.0848+/-0.0611+/-0.0781+/-0.117+/-0.0311+/-0.0277+/-1.08+/-0.124+/-0.0229+/-0.0565 0.0864 0.0335 0.204 0.0437 0.0309 0.0264 0.0276 0.0536 0.064 0.0566 0.0347 0.0425 0.0264 0.0236 0.174 0.0437 0.0193 0.0262+/-0.265+/-0.0402+/-0.395+/-0.124+/-0.0507+/-0.057+/-0.0445+/-0.0636+/-0.0848+/-0.0611+/-0.0781+/-0.117+/-0.0311+/-0.0277+/- 1.08+/-0.124+/-0.0229+/-0.0565 0.187 0.0691 0.435 0.0933 0.0661 0.0562 0.0608 0.113 0.143 0.117 0.0721 0.0895 0.0568 0.0502 0.402 0.0933 0.0409 0.0557 0.0358 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/07/06 1944 529777 1 BXFI 06/03/06 0904 534447 2 0.00427 +/-0.015 0.0158 +/-0.015 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 59 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www gel corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-004F Proiect: YANK01204 Sample ID: 162850013 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 82 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.60 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-005F 162850014 SE 28-APR-06 12-MAY-06 Client 15.8%Proiect: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 1.02 Americium-241 U -0.0104 Bismuth-212 0.766 Bismuth-214 0.842 Cesium-134 U 0.00 Cesium-137 0.409 Cobalt-60 1.94 Europium-152 U -0.0232 Europium-154 U 0.0616 Europium-155 UUI 0.00 Lead-212 1.15 Lead-214 0.982 Manganese-54 U 0.000439 Niobium-94 U -0.00364 Potassium-40 12.8 Radium-226 0.842 Silver-108m U -0.0143 Thallium-208 0.319 Rad Gas Flow Proportional Counting+/-0.249+/-0.116+/-0.337+/-0.119+/-0.0423+/-0.0547+/-0.162+/-0.0626+/-0.0724+/-0.0885+/-0.112+/-0,133+/-0.0292+/-0.0232+/- 1.20+/-0.119+/-0.0202+/-0.0531 0.0817 0.0918 0.182 0.0381 0.0291 0.0203 0.0189 0.0519 0.0653 0.0533 0.0295 0.0367 0.0244 0.0196 0.145 0.0381 0.0174 0.021+/-0.249+/-0.116+/-0.337+/-0.119+/-0.0423+/-0.0547+/-0.162+/-0.0626+/-0.0724+/-0.0885+/-0.112+/-0.133+/-0.0292+/-0.0232+/-1.20+/-0.119+/-0.0202+/-0.0531 0.172 0.189 0.379 0.0796 0.0607 0.0425 0.041 0.108 0.139 0.110 0.0609 0.0761 0.0511 0.0409 0.322 0.0796 0.0362 0.0438 0.0475 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 06/06/06 0916 529777 1 GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.0195 +/-0.0222 0.0214 +/-0.0222 BXFI 06/03/06 1010 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 61 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005F Project: YANK01204 Sample ID: 162850014 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 78 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.62 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-006F 162850015 SE 28-APR-06 12-MAY-06 Client 21.3%Project: Client ID: Vol. Recv.: YANK01204 YANKOOI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 UUI Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U 1.76-0.0427 1.15 1.23 0.00 0.130 0.241-0.0519-0.0354 0.00 1.76 1.30 0.0312 0.003 11.4 1.23-0.0111 0.544+/-0.238+/-0.0394+/-0.400+/-0.120+/-0.0387+/-0.0546+/-0.0752+/-0.0676+/-0.0796+/-0.106+/-0.0823+/-0.114+/-0.0479+/-0.0259+/-0.851+/-0.120+/-0.0244+/-0.0672 0.0865 0.0364 0.173 0.0445 0.0341 0.026 0.0248 0.0583 0.0664 0.0577 0.0341 0.0426 0.0271 0.0229 0.193 0.0445 0.0208 0.0236+/-0.238+/-0.0394+/-0.400+/-0.120+/-0.0387+/-0.0546+/-0.0752+/-0.0676+/-0.0796+/-0.106+/-0.0823+/-0.114+/-0.0479+/-0.0259+/-0.851+/-0.120+/-0.0244+/-0.0672 0.181 0.0741 0.361 0.0924 0.0706 0.0539 0.0525 0.120 0.141 0.118 0.0701 0.0879 0.0564 0.0475 0.416 0.0924 0.043 0.0491 0.0389 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/06/06 0916 529777 1 BXFI 06/03/06 1010 534447 2 0.00075 +1-0.0155 0.0173 +/-0.0155 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 63 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: 9106-0006-006F 162850015 Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 80 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC[MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.64 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-007F 162850016 SE 28-APR-06 12-MAY-06 Client 24.4%Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 UUI Cesium-137 U Cobalt-60 U Europium-152 U Europium-154 U Europium-155 UUI Lead-212 Lead-214 Manganese-54 U -Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.883-0.0496 0.618 0.548 0.00 0.0138 0.0158 0.0103-0.0167 0.00 0.850 0.640 0.00885 0.00505 14.7 0.548-0.0163 0.253+/-0.156+/-0.0591+/-0.216+/-0.0897+/-0.0306+/-0.0171+/-0.0167+/-0.041+/-0.0529+/-0.0724+/-0.0823+/-0.0887+/-0.0179+/-0.0151+/-1.11+/-0.0897+/-0.0138+/-0.0445 0.0431 0.0507 0.104 0.0246 0.0171 0.0143 0.0149 0.0357 0.0424 0.0418 0.0214 0.0241 0.0148 0.0133 0.120 0.0246 0.0109 0.0136+/-0.156+/-0.0591+/-0.216+/-0.0897+/-0.0306+/-0.0171+/-0.0167+/-0.041+/-0.0529+/-0.0724+/-0.0823+/-0.0887+/-0.0179+/-0.0151+/-1.11+/-0.0897+/-0.0138+/-0.0445 0.0917 0.104 0.219 0.0516 0.0358 0.0299 0.0317 0.0743 0.0903 0.0859 0.0441 0.0503 0.0312 0.0278 0.260 0.0516 0.0229 0.0285 0.0372 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/06/06 0917 529777 1 BXF1 06/03/06 1011 534447 2-0.01 +/-0.0125 0.0165 +/-0.0125 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 65 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-007F Project: YANKO 1204 Sample ID: 162850016 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 80 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.66 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com CprtiffirntP nf Ann vdie J-Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-007FS 162850017 SE 28-APR-06 12-MAY-06 Client 42.2%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Rad Gamma Spec Analysis Gamma,Solid-FSS GAM& ALL FSS Actinium-228 Americium-241 U -Bismuth-212 Bismnuth-214 Cesium-134 UUI Cesium-137 U Cobalt-60 U Europium-152 U Europium-154 U Europium-155 UUI Lead-212 Lead-214 Manganese-54 UUI Niobium-94 U Potassium-40 Radium-226 Silver-108m U 0 Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.869 0.00837 0.699 0.660 0.00 0.0098 0.0327-0.0156 0.0509 0.00 0.968 0.689 0.00-0.0162 12.8 0.660.000843 0.261+/-0.188+/-0.0303+/-0.376+/-0.110+/-0.0383+/-0.0244+/-0.0271+/-0.0607+/-0.0832+/-0.0737+/-0.0713+/-0.110+/-0.0239+/-0.0253+/-1.08+/-0.110+/-0.0202+/-0.0517 0.0734 0.0252 0.151 0.0369 0.0291 0.0211 0.0259 0.049 0.0738 0.0371 0.0265 0.0335 0.0231 0.0199 0.217 0.0369 0.0175 0.0205+/-0.188+/-0.0303+/-0.376+/-0.110+/-0.0383+/-0.0244+/-0.0271+/-0.0607+/-0.0832+/-0.0737+/-0.0713+/-0.110+/-0.0239+/-0.0253+/-1.08+/-0.110+/-0.0202+/-0.0517 0.160 0.0522 0.328 0.0792 0.0621 0.0455 0.057 0.104 0.162 0.0775 0.0556 0.0712 0.0497 0.0425 0.484 0.0792 0.0373 0.0439 0.0401 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 06/07/06 1946 529777 1 BXFI 06/03/06 1011 534447 2 0.0067 +/-0.0171 0.0175 +/-0.0171 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 67 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-007FS Project: YANK01204 Sample ID: 162850017 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Fracer Recovery GFPC, Sr90, solid-ALL FSS 70 (25- 125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has beerl confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.U1 Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.68 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-012F 162850018 SE 01-MAY-06 12-MAY-06 Client 24.1%Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 Cobalt-60 U Europium-152 U Europium-154 U -Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U -0.800 0.0264 0.580 0.592 0.0206 0.0271 0.00608-0.012 0.00336 0.0694 0.771 0.623 0.0055 1.810E-05 13.4 0.592-0.0103 0.248 Uncertainty

+/-0.102+/-0.0785+/-0.210+/-0.0649+/-0.0197+/-0.0198+/-0.0124+/-0.0336+/-0.0442+/-0.0419+/-0.046+/-0.0595+/-0.0156+/-0.0129+/-0.624+/-0.0649+/-0.0116+/-0.0304 LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.0385 0.0714 0.0896 0.0225 0.0149 0.0115 0.0109 0.0303 0.0368 0.0419 0.0191 0.0223 0.0134 0.011 0.0852 0.0225 0.00996 0.011+/-0.102+/-0.0785+/-0.210+/-0.0649+/-0.0197+/-0.0198+/-0.0124+/-0.0336+/-0.0442+/-0.0419+/-0.046+/-0.0595+/-0.0156+/-0.0129+/-0.624+/-0.0649+/-0.0116+/-0.0304 0.0815 0.147 0.188 0.0469 0.0311 0.0242 0.0234 0.0631 0.0781 0.0861 0.0393 0.0463 0.028 0.0229 0.187 0.0469 0.0208 0.0231 0.0352 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJI-1 06/06/06 1110 529777 1 Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U -0.00202 +/-0.0133 0.0154 +/-0.0133 BXFI 06/03/06 1011 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified 69 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-012F Project: YANKO1204 Sample ID: 162850018 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 81 (25%-/125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.70 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 9, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-017F 162850019 SE 01-MAY-06 12-MAY-06 Client 29.2%Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS Actinium-228 0.885 Americium-241 U -0.00501 Bismuth-212 0.680 Bismuth-214 0.665 Cesium-134 UUI 0.00 Cesium-137 U 0.0234 Cobalt-60 U 0.0144 Europium-152 U 0.0204 Europium-154 U 0.0238 Europium-155 U 0.00 Lead-212 0.952 Lead-214 0.777 Manganese-54 U 0.00158 Niobium-94 U 0.00894 Potassium-40 15.4 Radium-226 0.665 Silver-108m U -0.00124 Thallium-208 0.279 Rad Gas Flow Proportional Counting+/-0.134+/-0.119+/-0.230+/-0.0788+/-0.0291+/-0.0159+/-0.0182+/-0.0405+/-0.053+/-0.053+/-0.0553+/-0.0713+/-0.0195+/-0.0154+/-0.723+/-0.0788+/-0.0142+/-0.0412 0.0432 0.082 0.105 0.026 0.0175 0.0131 0.016 0.0369 0.0454 0.0507 0.0227 0.0242 0.0136 0.0133 0.109 0.026 0.0123 0.0127+/-0.134+/-0.119+/-0.230+/-0.0788+/-0.0291+/-0.0159+/-0.0182+/-0.0405+/-0.053+/-0.053+/-0.0553+/-0.0713+/-0.0195+/-0.0154+/-0.723+/-0.0788+/-0.0142+/-0.0412 0.0917 0.169 0.220 0.0543 0.0367 0.0275 0.0339 0.0767 0.0962 0.104 0.0468 0.0504 0.0288 0.0277 0.237 0.0543 0.0257 0.0266 0.0318 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 06/06/06 1729 529777 1 GFPC, Sr9O, solid-ALL FSS Strootium-90 U -0.00321 +/-0.0118 0.014 +/-0.0118 BXFI 06/03/06 1011 534447 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/15/06 0854 529740 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/14/06 1558 529739 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 71 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 9, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-017F Project: YANKO1204 Sample ID: 162850019 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 95 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.72 I QUALITY CONTROL DATA 73 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client: Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: June 9, 2006 Page 1 of 9 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

162850 Parmname NOM Sample Qual OC Units RPD%REC% Ran2e Anist Date Time Rad Alpha Spec Batch 533471 QC1201101118 Americium-24 I Curium-242 Curium-243/244 QC1201101120 Americium-24 I Curium-242 Curium-243/244 QC1201101117 Americium-241 162485017 DUP U -0.0415 Uncert: +/-0.0591 TPU: +/-0.0591 U -0.00755 Uncert: +/-0.0634 TPU: +/-0.0634 U 0.00112 Uncert: +/-0.0607 TPU: +/-0.0607 LCS MB 12.2 Uncert: TPU: Uncert: TPU: 14.9 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U -0.00249+/-0.0219+/-0.0219 U 0.0283+/-0.0555+/-0.0556 U 0.0131+/-0.0521+/-0.052 1 10.8+/-0.975+/-1.73 U -0.0056+/-0.047+/-0.0471 12.4+/-1.04+/-1.95 U -0.00902+/-0.019+/-0.019 U 0.0399+/-0.0638+/-0.064 U 0.0392+/-0.0626+/-0.0628 pCi/g 177 pCi/g 346 pCi/g 168 (0% -100%) LCWI 05/30/06 11:55 Curium-242 Curium-243/244 QC1201101119 162485017 MS Americium-241 Curium-242 Curium-243/244 pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g 89 (75%-125%)

83 (75%-125%)

(0% -100%)(0%- 100%)05/30/06 11:55 05/30/06 11:55 12.7 U -0.0415 Uncert: +/-0.0591 TPU: +/-0.0591 U -0.00755 Uncert: +/-0.0634 TPU: +/-0.0634 15.5 U 0.00112 Uncert: +/-0.0607 TPU: +/-0.0607 U 12.5+/-1.06+/- 1.96 0.00+/-0.0517+/-0.0517 12.6+/-1.06+/-1.98 98 (75%-125%)

05/30/06 11:55 81 (75%-125%)

Batch 533472 QC1201101122 162485017 DUP Plutonium-238 U 0.0261 U 0.00 pCi/g (0%- 100%) .CWI 05/30/06 21:29 74 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

162850 Page 2 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 533472 Plutonium-239/240 QC1201101124 LCS Plutonium-238 Plutonium-239/240 QC1201101121 MB Plutonium-238 Plutonium-239/240 QC1201101123 162485017 MS Plutonium-238 Plutonium-239/240 Uncert: +/-0.0511 TPU: +/-0.0512 u 0.0459 Uncert: +/-0.0733 TPU: +/-0.0734 Uncert: TPU: 11.3 Uncert: TPU: Uncert: TPU: Uncert: TPU: U 0.0261 Uncert: +/-0.0511 TPU: +/-0.0512 11.7 U 0.0459 Uncert: +/-0.0733 TPU: +/-0.0734 U -8.66 Uncert: +/-8.72 TPU: +/-8.77+/-0.0498+/-0.0498 U -0.00609+/-0.0511+/-0.0512 0.216+/-0.181+/-0.182 10.3+/-1.21+/-1.76 U -0.00623+/-0.0692+/-0.0693 U -0.0274+/-0.100+/-0.100 pCi/g 261 (0%- 100%)(75%-125%)

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 05/30/06 21:29 91 (75%-125%)

05/31/06 07:44 U 0.0634+/-0.0787+/-0.079 10.7+/-0.971+/-1.52 (75%-125%)

05/30/06 21:29 92 (75%-125%)

Batch 533473 QC1201101126 162485017 DUP Plutonium-241 QC1201101128 LCS Plutonium-241 QC1201101125 Plutonium-241 MB 131 Uncert: TPU: Uncert: TPU: 135 U Uncert: TPU: U -6.36+/-6.79+/-6.82 106+/-12.3+/-16.4 U -1.18+/-9.02+/-9.02 pCi/g pCi/g pCi/g 81 (75%-125%)

pCi/g 0 (0% -100%) .CW I 06/03/06 07:35 06/03/06 08:07 06/03/06 07:18 06/03/06 07:51 QC1201101127 162485017 MS Plutonium-241 Rad Gamma Spec Batch 529777 QC1201092336 162850001 DUP Actinium-228

-8.66+/-8.72+/-8.77 146+/-14.7+/-20.1 108 (75%-125%)

0.908+/-0.297 Uncert: 0.991+/-0.200+/-0.200 pCi/g 9 (0% -100%) MJHI 06/06/06 17:30 75 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

162850 Page 3 of 9 Parmname NOM Samnle Oual OC Units RPD%REC% Range Anist Date Time Rad Gamma Spec Batch 529777 Americium-241 Bismuth-212 Bismoth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU: +/-0.297 u -0.0354 U Uncert: +/-0.0542 TPU: +/-0.0542 U 0.292 Uncert: +/-0.518 TPU: +/-0.518 0.606 UUI Uncert: +/-0.164 TPU: +/-0.164 U 0.0697 UUI Uncert: +/-0.0502 TPU: +/-0.0502 U 0.00312 U Uncert: +/-0.0432 TPU: +/-0.0432 U 0.047 U Uncert: +/-0.0461 TPU: +/-0.0461 U 0.0184 U Uncert: +/-0.100 TPU: +/-0.100 U -0.039 U Uncert: +/-0.132 TPU: +/-0.132 U 0.0871 U Uncert: +/-0.0891 TPU: +/-0.0891 0.878 Uncert: +/-0.106 TPU: +/-0.106 0.438 Uncert: +/-0.111 TPU: +/-0.111 U 0.029 U Uncert: +/-0.0728 TPU: +/-0.0728 U -0.000518 U Uncert: +/-0.0403 TPU: +/-0.0403 16.0 Uncert: +/-1.34 TPU: +/-1.34 0.606 Uncert: +/-0.164 TPU: +/-0.164 U -0.0164 U Uncert: +/-0.0372-0.0552+/-0.0664+/-0.0664 0.971+/-0.279+/-0.279 0.00+/-0.0897+/-0.0897 0.00+/-0.0372+/-0.0372 0.00796+/-0.0195+/-0.0195 0.00696+/-0.0198+/-0.0198-0.0069+/-0.0474+/-0.0474-0.0214+/-0.0542+/-0.0542 0.00+/-0.0568+/-0.0568 0.940+/-0.0945+/-0.0945 0.476+/-0.0881+/-0.0881 0.0167+/-0.0198+/-0.0198 0.000452+/-0.0174+/-0.0174 15.9+/-1.25+/-1.25 0.416+/-0.0897+/-0.0897-0.0141+/-0.0155 pCi/g 44 pCi/g 108*(0%-100%)(0%-100%)pCi/g 37* (0%- 100%)Lead-212 Lead-214 pCi/g 25 pCi/g 87 pCi/g 148 pCi/g 440 pCi/g 59 pCi/g 27 pCi/g 7 pCi/g 8 pCi/g 54 pCi/g 2970 pCi/g I pCi/g 37 pCi/g 15 (0% -100%)(0%- 100%)(0%- 100%)(0% -100%)(0% -100%)(0%- 100%)(0% -20%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -20%)(0%- 100%)(0%- 100%)Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m 76 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

162850 Page 4 of 9 Parmname NOM Sample Qual OC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 529777 Thallium-208 TPU: +/-0.0372 0.422 Uncert: +/-0.0918 TPU: +/-0.0918+/-0.0155 0.278+/-0.0482+/-0.0482 pCi/g 41*Actinium-228 Americium-24 I LCS Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.64 Uncert: TPU: 15.1 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U 0.194+/-0.588+/-0.588 21.6+/- 1.42+/- 1.42 U -0.294+/-1.10+/-1.10 U -0.0783+/-0.242+/-0.242 U 0.0415+/-0.146+/-0.146 9.61+/-0.473+/-0.473 15.5+/-0.684+/-0.684 U 0.587+/-0.340+/-0.340 U -0.109+/-0.334+/-0.334 U 0.422+/-0.417+/-0.417 U -0.0619+/-0.187+/-0.187 U 0.114+/-0.234+/-0.234 U 0.0408+/-0.146+/-0.146 U 0.197+/-0.208+/-0.208 U 0.364 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 100 (75%-125%)

103 (75%-125%)

92 (75%-125%)

06/05/06 18:10 Lead-212 Lead-214 Mangatnese-54 Niobiurn-94 Potassitim-40 77 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

162850 Page 5 of 9 Pnrmna.mP NAM S-mnle O.al OC Units RPD% REC% Ranee Anist Date Time Parmname NOM I Rad Gamma Spec Batch 529777 Radium-226 Silver- 108m Thallium-208 QC1201092335 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 MB Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-1.23+/-1.23 U -0.0783+/-0.242+/-0.242 U 0.00944+/-0.139+/-0.139 U 0.0562+/-0.135+/-0.135 U 0.122+/-0.141+/-0.141 U 0.0315+/-0.0307+/-0.0307 U 0.0765+/-0.193+/-0.193 U 0.0567+/-0.0537+/-0.0537 U 0.022+/-0.0291+/-0.0291 U -0.00274+/-0.0276+/-0.0276 U 0.0134+/-0.0252+/-0.0252 U 0.0132+/-0.0615+/-0.0615 U 0.0414+/-0.0762+/-0.0762 U 0.0411+/-0.0525+/-0.0525 U 0.051+/-0.0368+/-0.0368 U 0.0556+/-0.0473+/-0.0473 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)

06/06/06 17:29 Lead-212 Lead-214 78 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

162850 Page 6 of 9 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Gamma Spec Batch 529777 Manganese-54 Niobium-94 Potassium-40 Radium-226 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U 0.00722+/-0.0283+/-0.0283 U 0.0168+/-0.0246+/-0.0246 U 0.159+/-0.284+/-0.284 U 0.0567+/-0.0537+/-0.0537 U 0.00464+/-0.0224+/-0.0224 U 0.0292+/-0.0271+/-0.0271 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Silver-108m Thallium-208 Rad Gas Flow Batch 534447 QC1201103431 162850003 DUP Strontium-90 QC1201103433 LCS Strontium-90 QC1201103430 MB Strontium-90 QC1201103432 162850003 MS Strontium-90 Rad Liquid Scintillation Batch 531618 QC1201096632 163173001 DUP Iron-55 U -0.00381 Uncert: +/-0.00625 TPU: +/-0.00626 U 0.00938+/-0.0172+/-0.0172 0.819+/-0.0656+/-0.070 pCi/g 0 (0% -100%) BXFI 1.09 Uncert: TPU: Uncert: TPU: 1.43 U Uncert: TPU: U 0.00139+/-0.0121.+/-0.0121 pCi/g pCi/g pCi/g 76 (75%-125%)

06/03/06 14:46 06/05/06 21:17 06/03/06 14:46 06/03/06 14:46-0.00381+/-0.00625

+/-0.00626 1.34+/-0.0899+/-0.0952 93 (75%-125%)

U 10.3 Uncert: +/-20.1 TPU: +/-20.1 U 5.38+/-18.0+/-18.1 pCi/g 0 (0% -100%) SLNI QC1201096634 LCS Iron-55 437 Uncert: TPU: 428+/-40.6+/-62.3 pCi/g 98 (75%-125%)

05/31/06 12:49 05/31/06 13:22 05/31/06 12:32 QC1201096631 MB Iron-55 U 3.58 pCi/g 79 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

162850 Page 7 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Liquid Scintillation Batch 531618 Uncert: TPU: QC1201096633 163173001 MS Iron-55+/-24.7+/-24.7 544+/-39.3+/-69.3 569 U Uncert: TPU: 10.3+/-20.1+/-20.1 pCi/g 96 (75%-125%)

05/31/06 13:05 Batch 531622 QC1201096645 163173001 DUP Nickel-63 QC1201096647 LCS Nickel-63 QC1201096644 MB Nickel-63 QC1201096646 163173001 MS Nickel-63 U -6.64 Uncerl: +/-7.30 TPU: +/-7.31 362 Uncert: TPU: Uncert: TPU: 460 U Uncert: TPU: U -5.49+/-4.33+/-4.33 301+/-7.49+/-11.1 U -1.66+/-3.41+/-3.41 pCi/g pCi/g pCi/g pCi/g (0% -100%) SLNI 05/28/06 01:38 83 (75%-125%)

05/28/06 03:40 05/28/06 00:37 05/28/06 02:39-6.64+/-7.30+/-7.31 Batch 531704 QC1201096868 162583001 DUP Technetium-99 QC1201096870 LCS Technetium-99 QC1201096867 MB Technetium-99 QC1201096869 162583001 MS Technetium-99 U 0.161 Uncert: +/-0.254 TPU: +/-0.255 U 395+/-9.22+/-14.9 0.239+/-0.273+/-0.273 11.1+/-0.474+/-0.545 86 (75%-125%)

pCi/g 0 (0% -100%) SXEI 12.5 Uncert: TPU: Uncert: TPU: 13.1 U Uncert: TPU: U 0.163+/-0.214+/-0.214 pCi/g pCi/g pCi/g 89 (75%-125%)

05/31/06 00:27 05/31/06 01:00 05/31/06 00:11 05/31/06 00:44 0.161+/-0.254+/-0.255 11.6+/-0.583+/-0.649 89 (75%-125%)

Batch 531705 QC1201096878 162583001 DUP Tritium U 1.17 Uncert: +/-4.09 TPU: +/-4.09 U 6.01+/-4.70+/-4.70 pCi/g 0 (0% -100%) NXP I 05/28/06 09:10 05/28/06 10:14 QC1201096880 LCS Tritium 41.4 Uncert: TPU: 44.8+/-5.68+/-5.73 pCi/g 108 (75%-125%)

80 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

162850 Page 8 of 9 Parmname Rad Liquid Scintillation Batch 531705 NOM Sani iple Qual QC Units RPD% REC% Range Anist Date Time QC0201096877 MB Tritium QC1201096879 162583001 MS Tritium Uncert: TPU: U 0.0641+/-0.533+/-0.533 pCi/g pCi/g 06/03/06 05:11 05/28/06 09:42 45.7 U Uncert: TPU: 1.17+/-4.09+/-4.09 Batch 534984 QC1201104746 Carbon- 14 163173001 DUP U 0.00714 Uncert: +/-0.0996 TPU: +/-0.0996 U 52.3+/-6.44+/-6.50 0.00246+/-0.103+/-0.103 11.3+/-0.855+/-0.873 114 (75%-125%)

pCi/g 0 (0%- 100%) ATH2 06/05/06 03:00 QCI201104748 LCS Carbon- 14 QC1201104745 MB Carbon- 14 12.1 Uncert: TPU: Uncert: TPU: 12.9 U Uncert: TPU: U -0.0368+/-0.101+/-0.101 pCi/g pCi/g pCi/g 94 (75%-125%)

06/05/06 05:20 06/05/06 00:57 06/05/06 05:02 QC1201104747 163173001 MS Carbon- 14 0.00714+/-0.0996+/-0.0996 12.1+/-0.917+/-0.936 94 (75%-125%)

Notes: The Qualifiers in this report are defined as follows:*A BD C D H J N/A R U UI X Y A A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product Results are either below the MDC or tracer recovery is low Analyte has been confirmed by GC/MS analysis Results are reported from a diluted aliquot of the sample Analytical holding time was exceeded Value is estimated Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL Preparation or preservation holding time was exceeded 81 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

162850 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time h N/A indicates that spike recovery limits do not apply when sample concentration eceeds spike conc. by a factor of 4 or more.** Indicates analyte is a surrogate compound.^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a. control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.82 Table of Contents General Narrative

...................................................................

1 Chain of Custody And Supporting Dpcumentation

...........

5 Radiological Analysis ...........................................................

12 Sample Data Summary .......................................................

18 Q uality C ontrol D ata ............................................................

60 General Narrative 1 CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 170256 SDG: MSR #06-1160 September 6, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road'Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC (GEL)in Charleston, South Carolina on August 25, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and' signatures.

The laboratory received the following sample(s):

Sample ED Client Sample ID 170256001 9106-0006-005A 170256002 9106-0006-005B 170256003 9106-0006-005C 170256004 9106-0006-005D 170256005 9106-0005-010A 170256006 9106-0005-OIOB 170256007 9106-0005-OIOC 170256008 9106-0005-010D 170256009 9106-0014-033A GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.P.O. Box 30712 -Charleston, SC 29417 -2040 Savage Road (29407)Phone (843) 556-8171

  • Fax 243) 766-1178 -www.gel.com 170256010 9106-0014-033Bl 170256011 9106-0014-033C 170256012 9106-0014-033D 170256013 9106-0004-013A 170256014 9106-0004-013B 170256015 9106-0004-013C 170256016 9106-0004-013D 170256017 9106-0004-005A 170256018 9106-0004-005B 170256019 9106-0004-005C 170256020 9106-0004-005D Items of Note: There are no items of note.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engieering Laboratories (GEL) Standard Operating Procedures.

Any technical or administraive problems during analysis, data review, and reduction are listed below by analytic'll parameter.

Analytical Request: Twenty soil samples were analyzed for FSSGAM and Sr-90.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically a"d for completeness, for other than the conditions detailed above. Release of the data c6ntained in this hard copy data package has been authorized by the Laboratory Manager orla designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)Phone (843) 556-8171
  • Fax J43) 766-1178 -www.gel.com List of current GEL Certifications as of 06 September 2006 State Certification

-. --Calfifornia 6)115 ..... .____Colorado_

____ .... .(ent~ngtabs..

..-C onnecticut PH-016-9 Dept. of Navy NFESC413 4 EPA--- ---w J --FloridaINELAP E87156 Georgia E87156 (FLNELAP)Idaho N/A Illinois ._200029 Indiana C-SC-0I Kansas .........

E-i0332 Kentucky 90129 Maryland 270 Massachusetts M-,-SC-O 12 Michigan _ 9903 Nevada SC12__ New Jersey -SC002-New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R- 158 Oklahoma 990- 4 Pennsylvania South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A

-U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont N/A Virginia 00151 Washington C223 4 Chain of Custody And Supporting Documentation 5

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00511 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones (A c o Priority:

[] 30 D. 0 14 D. [] 7 D. Container r"-c ' 5 'f Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0006-005A 8/8/06 14:35 SE C BP X X Transferred from COC # 2006-00488 9106-0006-005B 8/8/06 15:08 SE C BP X X Transferred from COC # 2006-00488 9106-0006-005C 8/9/06 07:46 SE C BP X X Transferred from COC # 2006-00307 9106-0006-005D 8/9/06 08:18 SE C BP X x Transferred from COC # 2006-00307 NOTES: PO#: 002332 MSR#: 06-1160 SSWP#NA SLTP QA E] Radwaste QA Ej Non QA 1) Relinquished By Date/Time

2) Rec ved By Date/Time 3) Relinquished By Date/Time
4) Pceived By-(, ,Date/Time Samples Shipped Via: Z Fed Ex E]ups WiHand LI Other Bill of Lading #"V00a 4 611.? 6'4,-1 Internal Container Temp.: _ Deg. C Custody Sealed?Y0- NEI Custody Seal Intact?YC NEI K,.Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00512 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories

)2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones C, (A Priority:

] 30 D. Z 14 D. ] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0005-01 OA 8/9/06 09:03 SE C BP X X Transferred from COC # 2006-00489 9106-0005-010B 8/9/06 09:33 SE C BP X X Transferred from COC # 2006-00489 9106-0005-01OC 8/9/06 10:04 SE C BP X X Transferred from COC # 2006-00489 9106-0005-01OD 8/9/06 10:56 SE C BP X X Transferred from COC # 2006-00489 NOTES: PO #: 002332 MSR#: 06- 110 SSWP# NA Z LTP QA[I Radwaste QA 0 Non QA 1) Relinquished By J h-tC '- ý C4'r Dat /Time 9_-.4.-ol

//34_0 2 ceive~dBy 4 D e/Time Samples Shipped Via:[ Fed Ex El uPs El Hand[ Other Bill of Lading#q 00 4631 64 Internal Container Temp.: __ Deg. C Custody Sealed?YE? NO Custody Seal Intact?YO NO 3) Relinquished By 1ate/Time 49eceived By Mt -Dat=Time Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00513 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones CA Priority:

[] 30 D. N 14 D. ] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0014-033A 8/11/06 07:58 SE C BP X X Transferred from COC # 2006-00493 C9106-0014-033B 8/11/06 08:24 SE C BP X X Transferred from COC # 2006-00493 9106-0014-033C 8/11/06 08:45 SE C BP X X Transferred from COC # 2006-00493 9106-0014-033D 8/11/06 09:16 SE C BP X X Transferred from COC 4 2006-00493 NOTES: PO #: 002332 MSR #: 06-1160 SSWP# NA E LTP QA E1 Radwaste QA E] Non QA 3 Relinquished By Da e/Time 2) ived By Date/Time 3) Relinquished By Date/Time

4) R~vived By D- 1'ate/Time Samples Shipped Via:[ Fed Ex auPs l Hand E] Other Bill of Lading #T9wQ 404 1 q 6444q Internal Container Temp.: _ Deg. C_ Custody Sealed? -YO NO]Custody Seal Intact?YO NO]

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00520 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Cn ýn Priority:

[] 30 D. g 14 D. Z 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0004-013A 8/9/06 12:53 SE C BP X X Transferred from COC 2006-00490 9106-0004-013B 8/9/06 13:27 SE C BP X X Transferred from COC 2006-00490

'9106-0004-013C 8/9/06 13:57 SE C BP X X Transferred from COC 2006-00490 9106-0004-013D 8/9/06 14:28 SE C BP X X Transferred from COC 2006-00490 9106-0004-OOSA 8/9/06 14:58 SE C BP X X Transferred from COC 2006-00490 9106-0004-005B 8/10/06 07:41 SE C BP X X Transferred from COC 2006-00491 9106-0004-005C 8/10/06 08:09 SE C BP X X Transferred from COC 2006-00491 9106-0004-005D 8/10/06 08:49 SE C BP X X Transferred from COC 2006-00491 NOTES: PO #: 002332 MSR#4: 06-116 0 SSWP#NA 2 LTP QA El Radwaste QA[: Non QA 1) Relinquished By Date/rime

2) Re ived By -Date/Time J rto, A rz-g-r Y4-os //70 ,, 3) Relinquished By Date/Time 4 ceived By Date/Time Samples Shipped Via: Z Fed Ex El UPS LI Hand F1 Other Bill of Lading #7yoo 4 6'44'Internal Container Temp.:_ Deg. C Custody Sealed?YEO ND Custody Seal Intact?YEI NO
  • 1 Connecticut Yankee Staicment of Work for Analytical Lab Services-.CYis-Iso-Sool0
  • " .Figure 1. Samle Chec.-in List Dateffi~me R eVed__________________________

SDc3#: Work Order Number ___" Shipping Cdatainer IMAM Lf3L4YA Chainof Custqdy8.A# -W3 00.* 1. Custdy Seas.ofishppiigcontainer intact?...

Yes ;41o 2. Custody Seals dated and signed? Yes E1Ko I." 3. Chain-of-Custody eord pr.sent?" Yes.,r I.].4- Cooler iemperature Z 5. Vermiculite/packing materials is: Wet H]ry.].Number shipping o nta irj:j " 7. Sample holding times etxedd? .Yes [,go I.8. Samples have.....irCiitody seals.-....hazard labcls-e... .appropriate sample labels.9. Samnples amc:.gooil condition

..eCakdg-broken --Jav air bubbles Wer ay a,-aie ideti, in ,a l , ceit?I JO.II.Yes[JNo(<S.De=tiption ofanomalies(include ampIe numbers): ""______________"_____"______________I.

I;1:~1 10 CY-ISC-SOW-OO1 Connecticut Yankee Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List.c~i~ Reclve&:~

~ 7 4-Work Order Nutaber: ___________________

Shipping Cdntainer I :13 Ot T k'Lý- .Chain of Custody # 2Z440 6 -R- _72.-1. Custody Seals. on shipping container intact?.. -Yes ['olý2. Custody Seals dated and signed? Yes" (,1 3. Chain-of-Custody record present? Yes kr,1.N" O 4. Cooler temperature

._ 2 ', 5. Vermiculite/packing materials is: Wet V , a 6.: Number of samples in shipping container:

7. Sample hokling times exceeded?

Yes 4,- Io I 8. Samples have:.__e6ustody seals-.__hazard labels-appropriate sample labels 9. Samples are:_ in goqd condition._,,Zbroke

-ea'ng-...have air bubbles 10. Were any anomalies identified irt sample receipt? Yes [ 'Noo J 11. Description of anornalies (include sample mbers): 'D.. -9/t, -t /,f.' *k (includekfr sanpl nmb 11 RADIOLOGICAL ANALYSIS 12 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 170256 Method/Analysis Information Product: Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Sample ID 170256001 170256002 170256003 170256004 170256005 170256006 170256007 170256008 170256009 170256010 170256011 170256012 170256013 170256014 170256015 170256016 170256017 170256018 170256019 170256020 1201171525 1201171526 1201171527 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 563436 562444 Client ID 9106-0006-005A 9106-0006-005B 9106-0006-005C 9106-0006-005D 9106-0005-01OA 9106-0005-OIOB 9106-0005-OIOC 9106-0005-OIOD 9106-0014-033A 9106-0014-033B 9106-0014-033C 9106-0014-033D 9106-0004-013A 9106-0004-013B 9106-0004-013C 9106-0004-013D 9106-0004-005A 9106-0004-005B 9106-0004-005C 9106-0004-005D Method Blank (MB)170256001(9106-0006-005A)

Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this 13 narrative has been analyzed in accordance with GL-RAD-A-013 REV# 12.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170256001 (9106-0006-005A).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 170256007 (9106-0005-010C), 170256016 (9106-0004-013D) and 170256019 (9106-0004-005C) were recounted due to high MDAs.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Oualifier information 14 Qualifier U'UI Reason Data rejected due to high counting uncertainty Data rejected due to interference.

Data rejected due to low abundance.

UI Analyte Bismuth-212 Europium-155 Bismuth-214 Cesium- 134 Europium-155 Sample 170256009 170256003 170256009 170256019 170256020 170256008 170256005 170256007 170256008 170256012 170256013 170256019 1201171526 170256018 Method/Analysis Information Product: Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: GFPC, Sr90, solid-ALL FSS EPA 905.0 Modified Ash Soil Prep Dry Soil Prep 562563 562478 562444 15 Sample ID 170256001 170256002 170256003 170256004 170256005 170256006 170256007 170256008 170256009 170256010 170256011 170256012 170256013 170256014 170256015 170256016 170256017 170256018 170256019 170256020 1201169421 1201169422 1201169423 1201169424 Client ID 9106-0006-005A 9106-0006-005B 9106-0006-005C 9106-0006-005D 9106-0005-01OA 9106-0005-OIOB 9106-0005-01OC 9106-0005-OIOD 9106-0014-033A 9106-0014-033B 9106-0014-033C 9106-0014-033D 9106-0004-013A 9106-0004-013B 9106-0004-013C 9106-0004-013D 9106-0004-005A 9106-0004-005B 9106-0004-005C 9106-0004-005D Method Blank (MB)170256002(9106-0006-005B)

Sample Duplicate (DUP)170256002(9106-0006-005B)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Guality Control (0C0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 170256002 (9106-0006-005B).

16 QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples were recounted due to low/high recovery.Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

17 SAMPLE DATA

SUMMARY

18 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-1160 GEL Work Order: 170256 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 19 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result Uncertainty Report Date: September 8, 2006 9106-0006-005A 170256001 SE 08-AUG-06 25-AUG-06 Client 15.8%LC TPU MDA Project: YANK01204 Client ID: YANKOO Vol. Recv.: Units DF Analyst Date Time Batch Mtd Parameter Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.966 +/-0.192 Americium-241 U 0.0375 +/-0.0387 Bismuth-212 0.366 +/-0.306 Bismuth-214 0.650 +/-0.135 Cesium-134 U 0.0366 +/-0.0355 Cesium-137 0.0666 +/-0.0355 Cobalt-60 0'104 +/-0.0726 Europium-152 U 0.00636 +/-0.0728 Europium-154 U -0.0788 +/-0.0938 Europium-155 U 0.0672 +/-0.0554 Lead-212 0.871 +/-0.0971 Lead-214 0.727 +/-0.105 Manganese-54 U -0.00916 +/-0.0319 Niobium-94 U 0.0101 +/-0.0244 Potassium-40 11.3 +/-0.986 Radium-226 0.650 +/-0.135 Silver-108m U -0.0067 +/-0.0208 Thallium-208 0.283 +/-0.0618 Rad Gas Flow Proportional Counting 0.0743 0.0329 0.175 0.042 0.0288 0.0236 0.0286 0.0538 0.0718 0.0518 0.0305 0.0379 0.0232 0.0223 0.201 0.042 0.018 0.0212+/-0.192+/-0.0387+/-0.306+/-0.135+1-0.0355+1-0.0355+/-0.0726+/-0.0728+/-0.0938+1-0.0554+/-0.0971+/-0.105+/-0.0319+/-0.0244+/-0.986+/-0.135+/-0.0208+/-0.0618 0.149 0.0658 0.350 0.0839 0.0576 0.0472 0.0573 0.108 0.143 0.104 0.061 0.0757 0.0465 0.0445 0.403 0.0839 0.036 0.0423 0.0298 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 1057 563436 1 GFPC, SO9O, solid-ALL FSS Strontium-90 U 0.0254 +/-0.0193 0.0126 +/-0.0193 KSDI 09/07/06 1742 562563 2 The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Analyst Date Time Prep Batch LXM2 08/27/06 1545 562444 20 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005A Proiect: YANK01204 Sample ID: 170256001 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 96 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.21 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Ci~rtflgMirtp af Anqlvkic Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-005B 170256002 SE 08-AUG-06 25-AUG-06 Client 14.4%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actiniumn-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting GFPC, SO9O, solid ALL FSS Strontium-90 U 0.606 0.101 0.685 0.435 0.0313 0.114 0.436-0.0448-0.0186 0.0423 0.643 0.462-0.0167 0.00909 11.1 0.435 0.00194 0.243+/-0.152+/-0.114+/-0.232+/-0.0852+/-0.0286+/-0.0348+/-0.0586+/-0.0525+/-0.0685+/-0.0579+/-0.0623+/-0.0885+/-0.0261+/-0.0195+/-0.983+/-0.0852+/-0.0168+/-0.0457 0.0599 0.0861 0.134 0.0332 0.0238 0.0206 0.0151 0.0416 0.0562 0.0552 0.0268 0.033 0.0174 0.0173 0.179 0.0332 0.0149 0.0176+/-0.152+/-0.114+/-0.232+/-0.0852+/-0.0286+/-0.0348+/-0.0586+1-0.0525+/-0.0685+/-0.0579+/-0.0623+/-0.0885+/-0.0261+/-0.0195+/-0.983+/-0.0852+/-0.0168+/-0.0457 0.131 0.179 0.290 0.0708 0.0507 0.0438 0.0345 0.0882 0.124 0.114 0.056 0.0696 0.0377 0.0369 0.399 0.0708 0.0317 0.0377 0.0278 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pci/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 1220 563436 1 KSDI 09/07/06 1742 562563 2 0.00501 +/-0.0149 0.0117 +/-0.0149 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil.Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description LXM2 08/27/06 1545 562444 1 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 22 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005B Project: YANK01204 Sample ID: 170256002 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 101 (25%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.23 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-005C 170256003 SE 09-AUG-06 25-AUG-06 Client 31.7%Project: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.07 Americium-241 U 0.0251 Bismuth-212 0.684 Bismuth-214 0.673 Cesium-134 U 0.0516 Cesium-137 0.317 Cobalt-60 0.821 Europium-152 U -0.049 Europium-154 U 0.0883 Europium-155 UI 0.00 Lead-212 1.01 Lead-214 0.828 Manganese-54 U -0.0228 Niobium-94 U -0.0353 Potassium-40 12.4 Radium-226 0.673 Silver-108m U 0.00475 Thallium-208 0.382 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U 0.00738+/-0.284+/-0.0367+/-0.424+/-0.121 F/-0.0548+/-0.0544+/-0.0911 F/-0.0652 F/-0.0913+/-0.0926/-0.0819+/-0.117 F/-0.0296+/-0.0279+1-1.15+/-0.121/-0.0263 F/-0.0567 0.101 0.0332 0.178 0.0445 0.0344 0.0247 0.0294 0.0539 0.0839 0.0506 0.0329 0.0423 0.0238 0.0205 0.189 0.0445 0.0227 0.0242+/-0.284+/-0.0367+/-0.424+/-0.121+/-0.0548+/-0.0544+/-0.0911+/-0.0652+/-0.0913+/-0.0926+/-0.0819+/-0.117+/-0.0296+/-0.0279+/-1.15+/-0.121+/-0.0263+/-0.0567 0.215 0.0683 0.383 0.0947 0.0729 0.0528 0.064.0.114 0.182 0.105 0.0685 0.089 0.0513 0.044 0.431 0.0947 0.0477 0.0515 0.0255 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 09/01/06 1221 563436 1 KSDI 09/07/06 1745 562563 2/-0.0142 0.0107 +/-0.0142 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2. 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 24 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005C Project: YANKO 1204 Sample ID: 170256003 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 104 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.25 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result Uncertainty 9106-0006-005D 170256004 SE 09-AUG-06 25-AUG-06 Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Client 28.2%LC TPU MDA Units DF Analyst Date Time Batch Mtd Parameter Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium- 137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0 1.01 0.0605 0.534 0.594 0.0478 0.103 0.148 0.00143 0.0154 0.0625 0.900 0.854-0.013 0.0144 11.6 0.594 0.0118 0.310+/-0.197+/-0.132+/-0.328+1-0.105+/-0.046+/-0.0401+/-0.0644+/-0.0589+/-0.0766+/-0.0643+/-0.0831+/-0.106+/-0.0244+/-0.022+/-0.886+1-0.105+/-0.0187+/-0.0591 0.0659 0.088 0.168 0.0384 0.0253 0.0181 0.0204 0.0517 0.0653 0.0586 0.0345 0.0372 0.0203 0.0192 0.177 0.0384 0.0169 0.0199+/-0.197+/-0.132+/-0.328+1-0.105+/-0.046+/-0.0401+/-0.0644+/-0.0589+/-0.0766+/-0.0643+/-0.0831+/-0.106+/-0.0244+/-0.022+/-0.886+/-0.105+/-0.0187+/-0.0591 0.143 0.182 0.358 0.0813 0.0537 0.0389 0.045 0.109 0.142 0.121 0.0714 0.078 0.0434 0.0408 0.396 0.0813 0.0357 0.0422 0.0376 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 1221 563436 1 KSD1 09/07/06 1740 562563 2.000446 +/-0.0198 0.0166 +/-0.0198 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified LXM2 08/27/06 1545 562444 Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 26 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005D Proiect: YANK01204 Sample ID: 170256004 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 50 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.27 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Parameter Qualifier Result Ur Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.22 Americium-241 U 0.0503 -+Bismuth-212 0.628 Bismuth-214 0.834 Cesium-134 UI 0.00 +Cesium-137 U 0.0463 4 Cobalt-60 U 0.077 4 Europium-152 U 0.00822 4 Europium-154 U-0.000512 Europium-155 U 0.0659 Lead-212 0.933 Lead-214 0.787 Manganese-54 U -0.0199 4 Niobium-94 U -0.0359 +Potassium-40 20.0 Radium-226 0.834 Silver-108m U -0.00415 +Thallium-208 0.347 +Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00442 +9106-0005-010A 170256005 SE 09-AUG-06 25-AUG-06 Client 60.7%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 ncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.394--0.0522+/-0.547+/-0.160/-0.0832-/-0.0542-/-0.0516-/-0.0958+/-0.129+/-0.115+/-0.111+/-0.146 1-0.0442-/-0.0364+1-1.50+/-0.160/-0.0338/-0.0918 0.120 0.0424 0.277 0.0633 0.0429 0.0333 0.0472 0.0766 0.0917 0.0674 0.0593 0.0602 0.0342 0.0275 0.288 0.0633 0.0282 0.0332+/-0.394+/-0.0522+/-0.547+/-0.160+/-0.0832+/-0.0542+/-0.0516+/-0.0958+/-0.129+/-0.115+/-0.111+/-0.146+/-0.0442+/-0.0364+/-1.50+/-0.160+/-0.0338+/-0.0918 0.255 0.0872 0.584 0.133 0.0903 0.0703 0.100 0.160 0.199 0.139 0.122 0.125 0.0725 0.0583 0.634 0.133 0.0591 0.0698 0.0274 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/01/06 1221 563436 1 KSD1 09/07/06 1745 562563 2*/-0.0146 0.0116 +/-0.0146 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 28 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-OIOA Project: YANK01204 Sample ID: 170256005 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 103 (25%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.29 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0005-OIOB 170256006 SE 09-AUG-06 25-AUG-06 Client 61.3%Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.10 +/-0.245 Americium-241 U -0.00576 +/-0.0366 Bismuth-212 0.760 +/-0.351 Bismuth-214 0.576 +/-0.139 Cesium-134 U 0.0332 +/-0.0438 Cesium-137 0.0908 +/-0.0468 Cobalt-60 0.115 +/-0.0522 Europium-152 U 0.00833 +/-0.068 Europium-154 U -0.0828 +/-0.106 Europium-155 U 0.0871 +/-0.0591 Lead-212 1.08 +/-0.0778 Lead-214 0.812 +/-0.0928 Manganese-54 U 0.0145 +/-0.0313 Niobium-94 U 0.00876 +/-0.0271 Potassium-40 19.3 +/-1.35 Radium-226 0.576 +/-0.139 Silver-108m U -0.00887 +/-0.0232 Thallium-208 0.282 +/-0.0641 Rad Gas Flow Proportional Counting 0.0778 0.0263 0.189 0.0442 0.0314 0.0231 0.0225 0.0546 0.0808 0.0504 0.0306 0.0385 0.0262 0.0226 0.236 0.0442 0.0191 0.0224+/-0.245+/-0.0366+/-0.351+/-0.139+/-0.0438+/-0.0468+/-0.0522+/-0.068+/-0.106+/-0.0591+/-0.0778+/-0.0928+/-0.0313+/-0.0271+/-1.35+/-0.139+/-0.0232+/-0.0641 0.168 0.0543 0.402 0.0936 0.0665 0.0493 0.0499 0.115 0.175 0.104 0.0636 0.081 0.0557 0.0479 0.521 0.0936 0.0403 0.0475 0.0368 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 1221 563436 1 GFPC, Sr9O, solid-ALL FSS Strontium-90 U -0.00561 +/-0.0185 0.0162 +/-0.0185 KSDI 09/07/06 1746 562563 2 The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 Analyst Date Time Prep Batch LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 30 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-010B Project: YANK01204 Sample ID: 170256006 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 89 (25/-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UT Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.31 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: '362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0005-010C 170256007 SE 09-AUG-06 25-AUG-06 Client 49.2%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.05 Americium-241 U 0.00111 Bismuth-212 0.539 Bismuth-214 0.626 Cesium-134 UI 0.00 Cesium-137 0.192 Cobalt-60 0.522 Europium-152 U -0.0379 Europium-154 U -0.0318 Europium-155 U 0.0641 Lead-212 1.14 Lead-214 0.753 Manganese-54 U 0.0134 Niobium-94 U 0.0073 Potassium-40 17.9 Radium-226 0.626 Silver-108m U 0.00496 Thallium-208 0.354 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.00471+/-0.196+/-0.108+/-0.392+/-0.101+/-0.0318+/-0.0408+/-0.0639+/-0.0596+/-0.0732+/-0.0925+/-0.0696+/-0.0911+/-0.0217+/-0.0216+/-1.02+/-0.101+/-0.0191+/-0.0504 0.0698 0.0862 0.142 0.0371 0.025 0.0197 0.0211 0.0464 0.0585 0.0488 0.0264 0.0337 0.0193 0.0181 0.190 0.0371 0.0165 0.0183+/-0.196+/-0.108+/-0.392+/-0.101+/-0.0318+/-0.0408+/-0.0639+/-0.0596+/-0.0732+/-0.0925+/-0.0696+/-0.0911+/-0.0217+/-0.0216+/-1.02+/-0.101+/-0.0191+/-0.0504 0.148 0.177 0.300 0.0775 0.0524 0.0414 0.0453 0.0966 0.126 0.100 0.0544 0.070 0.0408 0.038 0.412 0.0775 0.0344 0.0384 0.027 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/05/06 2124 563436 1 KSD1 09/07/06 1758 562563 2+/-0.0144 0.0114 +/-0.0145 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 32 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-OIOC Project: YANKO 1204 Sample ID: 170256007 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits CarrierFIracer Recovery GFPC, Sr90, solid-ALL FSS 101 (25°/w- 125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UlI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.33 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0005-010D 170256008 SE 09-AUG-06 25-AUG-06 Client 58.1%Proiect: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.920 +/-0.431 Americium-241 U 0.159 +/-0.0868 Bismuth-212 0.975 +/-0.615 Bismuth-214 U1 0.00 +/-0.170 Cesium-134 UI 0.00 +/-0.0619 Cesium-137 0.630 +/-0.105 Cobalt-60 2.24 +/-0.161 Europium-152 U 0.0801 +/-0.100 Europium-154 U 0.159 +/-0.180 Europium-155 U 0.0923 +/-0.117 Lead-212 1.10 +/-0.108 Lead-214 0.707 +/-0.194 Manganese-54 U 0.0291 +/-0.050 Niobium-94 U 0.0114 +/-0.0446 Potassium-40 16.4 +/-1.57 Radium-226 0.761 +/-0.170 Silver-108m U 0.00643 +/-0.0377 Thallium-208 0.396 +/-0.103 Rad Gas Flow Proportional Counting 0.163 0.0423 0.310 0.126 0.0563 0.037 0.0361 0.0874 0.124 0.0649 0.0414 0.0578 0.0419 0.0367 0.341 0.0744 0.0316 0.0362+/-0.431+/-0.0868+/-0.615+/-0.170+/-0.0619+/-0.105+/-0.161+/-0.100+/-0.180+/-0.117+/-0.108+/-0.194+/-0.050+/-0.0446+/- 1.57+/-0.170+/-0.0377+/-0.103 0.345 0.0871 0.654 0.259 0.118 0.0784 0.0793 0.182 0.267 0.134 0.086 0.121 0.0886 0.0774 0.753 0.156 0.0662 0.0763 0.0315 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 1222 563436 1 GFPC, Sr90, solid-ALL FSS Strontium-9 0 U 0.0219 +/-0.0196 0.0135 +/-0.0196 KSD1 09/07/06 1805 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 34 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-OIOD Project: YANKO 1204 Sample ID: 170256008 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 97 (25%- 125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.35 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-033A 170256009 SE 1 I-AUG-06 25-AUG-06 Client 26.2%Project: Client ID: Vol. Recv.: YANKO 1204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.28 Americium-241 U 0.0199 Bismuth-212 UI 0.00 Bismuth-214 0.920 Cesium-134 U 0.0188 Cesium-137 0.709 Cobalt-60 0.697 Europium-152 U -0.0119 Europium-154 U 0.0763 Europium-155 UI 0.00 Lead-212 1.13 Lead-214 1.04 Manganese-54 U -0.0049 d Niobium-94 U 0.014 Potassium-40 14.3 Radium-226 0.920 Silver-108m U3.080E-05

+Thallium-208 0.405 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 0.0366 ++/-0.272+/-0.0632+/-0.484+/-0.139+/-0.0338+/-0.0983+/-0.0935/-0.0643/-0.0741/-0.0951+/-0.134+/-0.151-/-0.0275-/-0.0236+/-1.30+/-0.139-/-0.0263+/-0.066 0.0796 0.0541 0.171 0.0421 0.0298 0.0246 0.0267 0.0538 0.0675 0.052 0.0457 0.0416 0.023 0.0211 0.185 0.0421 0.0202 0.0235+/-0.272+/-0.0632+/-0.484+/-0.139+/-0.0338+/-0.0983+/-0.0935+/-0.0643+/-0.0741+/-0.0951+/-0.134+/-0.151+/-0.0275+/-0.0236+/-1.30+/-0.139+/-0.0263+/-0.066 0.171 0.112 0.363 0.089 0.0628 0.0519 0.0577 0.113 0.147 0.108 0.0938 0.0871 0.049 0.0446 0.412 0.089 0.0424 0.0495 0.0291 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJI-ll 09/01/06 1223 563436 1 KSDI 09/07/06 1807 562563 2-/-0.0205 0.0124 +/-0.0205 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 36 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033A Project: YANKO1204 Sample ID: 170256009 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 99 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria* Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UT Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.37 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-033B 170256010 SE 11-AUG-06 25-AUG-06 Client 16.3%Prolect: Client ID: Vol. Recv.: YANKO 1204 YANKOO Parameter (Rad Gamma Spec Analysis:ualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.03 +/-0.272 Americium-241 U 0.037 +/-0.0519 Bismuth-212 0.897 +/-0.563 Bismuth-214 0.681 +/-0.143 Cesium-134 U 0.062 +/-0.0748 Cesium-137 0.862 +/-0.117 Cobalt-60 0.944 +/-0.113 Europium-152 U 0.00733 +/-0.118 Europium-154 U 0.00812 +/-0.115 Europium-155 U 0.0592 +/-0.0677 Lead-212 0.896 +/-0.109 Lead-214 0.773 +/-0.141 Manganese-54 U -0.0465 +/-0.0487 Niobium-94 U 0.00334 +/-0.0333 Potassium-40 11.6 +/-1.25 Radium-226 0.681 +/-0.143 Silver-108m U -0.00313 +/-0.0324 Thallium-208 0.278 +/-0.0682 Rad Gas Flow Proportional Counting 0.113 0.0353 0.237 0.057 0.0371 0.0301 0.0281 0.0695 0.0959 0.0595 0.0377 0.0491 0.032 0.029 0.247 0.057 0.0274 0.0296+/-0.272+/-0.0519+/-0.563+/-0.143+/-0.0748+/-0.117+/-0.113+/-0.118+1-0.115+/-0.0677+/-0.109+/-0.141+/-0.0487+/-0.0333+/- 1.25+/-0.143+/-0.0324+/-0.0682 0.225 0.0705 0.473 0.114 0,0742 0,0601 0,0562 0.139 0.192 0.119 0.0754 0.0981 0.0639 0.0579 0.494 0.114 0.0548 0.0592 0.0268 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHIl 09/01/06 1559 563436 1 KSDI 09/07/06 1807 562563 2 GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00794 +1-0.015 0.0113 +1-0.015 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 38 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033B Proiect: YANK01204 Sample ID: 170256010 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 103 (25%-9125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.39 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-033C 170256011 SE 1 1-AUG-06 25-AUG-06 Client 14.2%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.841 +/-0.277 Americium-241 U 0.028 +/-0.048 Bismuth-212 0.476 +/-0.345 Bismuth-214 0.628 +/-0.128 Cesium-134 U 0.0398 +/-0.0385 Cesium-137 0.609 +/-0.0698 Cobalt-60 0.916 +/-0.0989 Europium-152 U -0.0803 +/-0.0732 Europium-154 U -0.0175 +/-0.0895 Europium-155 U 0.0335 +/-0.0642 Lead-212 0.710 +/-0.0819 Lead-214 0.810 +/-0.110 Manganese-54 U -0.0149 +/-0.0338 Niobium-94 U -0.00772 +/-0.0304 Potassium-40 11.0 +/-1.00 Radium-226 0.628 +/-0.128 Silver-108m U 0.0295 +/-0.0254 Thallium-208 0.237 +/-0.0761 Rad Gas Flow Proportional Counting 0.100 0.0331 0.223 0.0439 0.0344 0.0277 0.0255 0.0581 0.0738 0.0553 0.0392 0.0428 0.0272 0.0254 0.220 0.0439 0.0239 0.0244+/-0.277+/-0.048+/-0.345+/-0.128+/-0.0385+/-0.0698+/-0.0989+/-0.0732+/-0.0895+/-0.0642+/-0.0819+/-0.110+/-0.0338+/-0.0304+/-1.00+/-0.128+/-0.0254+/-0.0761 MDA 0.212 0.068 0.468 0.0928 0.0721 0.0581 0.0552 0.121 0.159 0.114 0.0808 0.0895 0.0575 0.0533 0.484 0.0928 0.0499 0.0513 0.0359 Units DF Analyst Date Time Batch Mtd pci/g pCi/g pCi/g pCi/g pCi/g pCi/g pci/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pci/g pCi/g MJH1 09/01/06 1829 563436 1 GFPC, Sr90, solid-ALL FSS Strontiurn-90 U -0.0326 +/-0.013 0.0158 +/-0.013 KSDI 09/07/06 1842 562563 2 The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description Analyst Date Time Prep Batch LXM2 08/27/06 1545 562444 1 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified 40 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033C Project: YANK01204 Sample ID: 170256011 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 90 (25%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, NyDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.41 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 lnjun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0014-033D 170256012 SE 1 I-AUG-06 25-AUG-06 Client 11.9%Proiect: YANK01204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.800 +/-0.169 Americium-241 U -0.00757 +/-0.0849 Bismuth-212 0.514 +/-0.239 Bismuth-214 0.496 +/-0.079 Cesium-134 UI 0.00 +/-0.0333 Cesium-137 0.240 +/-0.0466 Cobalt-60 0.329 +/-0.0616 Europium-152 U -0.0221 +/-0.047 Europium-154 U -0.0277 +/-0.0651 Europium-155 U 0.0409 +/-0.050 Lead-212 0.618 +/-0.0549 Lead-214 0.582 +/-0.0773 Manganese-54 U 0.0209 +/-0.0191 Niobium-94 U 0.0124 +/-0.0174 Potassium-40 10.8 +/-0.796 Radiumn-226 0.496 +/-0.079 Silver-108m U -0.00363 +/-0.0168 Thallium-208 0.222 +/-0.040 Rad Gas Flow Proportional Counting 0.0584 0.0733 0.125 0.0289 0.0215 0.0172 0.0159 0.0418 0.0444 0.0464 0.0246 0.0304 0.0165 0.0157 0.144 0.0289 0.0148 0.0156+/-0.169+/-0.0849+/-0.239+/-0.079+/-0.0333+/-0.0466+/-0.0616+/-0.047+/-0.0651+/-0.050+/-0.0549+/-0.0773+/-0.0191+/-0.0174+/-0.796+/-0.079+/-0.0168+/-0.040 0.125 0.151 0.265 0.0614 0.0454 0.0365 0.0349 0.0875 0.0974 0.0959 0.0511 0.0635 0.0352 0.0331 0.320 0.0614 0.0312 0.033 0.0276 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/05/06 0531 563436 1 GFPC, SO9O, solid-ALL FSS Strontium-90 U 0.020 +/-0.0174 0.0117 +/-0.0174 KSDI 09/07/06 1842 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 42 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0014-033D Project: YANKO1204 Sample ID: 170256012 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/[racer Recovery GFPC, Sr90, solid-ALL FSS 103 (25%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.43 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-013A 170256013 SE 09-AUG-06 25-AUG-06 Client 17.1%Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 lngrowth Waived Actinium-228 1.15 Americium-241 U 0.0596 Bismtth-212 0.731 Bismuth-214 0.959 Cesium-134 UI 0.00 Cesium-137 U -0.00113 Cobalt-60 U -0.00569 Europium-152 U -0.0275 Europium-154 U -0.0292 Europium-155 U 0.0375 Lead-212 1.19 Lead-214 1.08 Manganese-54 U 0.0199 Niobium-94 U -6.020E-+/-0.162+/-0.0865+/-0.295+/-0.0845+/-0.0287+/-0.0196+/-0.0174+/-0.0539+/-0.0495+/-0.0594+/-0.0671+/-0.090+/-0.0202+/-0.0164+/-0.771+/-0.0845+/-0.0152+/-0.0539 0.0511 0.0665 0.115 0.0284 0.0195 0.0162 0.0139 0.0402 0.0385 0.0534 0.0261 0.0305 0.0165 0.0143 0.130 0.0284 0.0128 0.0142+/-0.162+/-0.0865+/-0.295+/-0.0845+/-0.0287+/-0.0196+/-0.0174+/-0.0539+/-0.0495+/-0.0594+/-0.0671+/-0.090+/-0.0202+/-0.0164+/-0.771+/-0.0845+/-0.0152+/-0.0539 0.109 0.136 0.242 0.0597 0.041 0.034 0.0301 0.0837 0.0835 0.110 0.0537 0.0634 0.0347 0.030 0.283 0.0597 0.0268 0.030 0.0304 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 1830 563436 1 Potassium-40 Radium-226 Silver-108m U -Thallium-208 Rad Gas Flow Proportional Counting 05 14.3 0.959 0.00566 0.423 GFPC, SO9O, solid-ALL FSS Strontium-90 U -0.00331 +1-0.0151 0.0131 +/-0.0151 KSD1 .09/07/06 1842 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 2 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified 44 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013A Project: YANKO 1204 Sample ID: 170256013 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 101 (25o-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.45 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Ana1vqiv Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-013B 170256014 SE 09-AUG-06 25-AUG-06 Client 19.6%Prolect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.23 Americium-241 U 0.0581 Bismuth-212 0.606 Bismuth-214 0.990 Cesium-134 U 0.0447 Cesium-137 0.0831 Cobalt-60 0.196 Europium-152 U 0.0248 Europium-154 U 0.0401 Europium-155 U 0.067 Lead-212 1.32 Lead-214 0.989 Manganese-54 U -0.00696 Niobium-94 U 0.00306 Potassium-4 0 9.89 Radium-226 0.990 Silver-108m U -0.017 Thallium-208 0.456 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.00221+/-0.302+/-0.0456+/-0.361+/-0.154+/-0.0383+/-0.037 F/-0.0645+/-0.116+/-0.106+/-0.0826+/-0.136+/-0.153+/-0.0306+/-0.0256+/-0.996+/-0.154+/-0.0253+/-0.084 0.0948 0.0383 0.199 0.046 0.033 0.0286 0.0258 0.061 0.0809 0.0584 0.0337 0.0431 0.0262 0.0228 0.207 0.046 0.0211 0.0253+/-0.302+/-0.0456+/-0.361+/-0.154+/-0.0383+/-0.037+/-0.0645+/-0.116+/-0.106+/-0.0826+/-0.136+/-0.153+/-0.0306+/-0.0256+/-0.996+/-0.154+/-0.0253+/-0.084 0.190 0.0765 0.399 0.0919 0.066 0.0571 0.0515 0.122 0.162 0.117 0.0674 0.0862 0.0523 0.0455 0.414 0.0919 0.0422 0.0505 0.0316 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/01/06 2110 563436 1 KSDI 09/07/06 1843 562563 2/-0.0172 0.0143 +/-0.0172 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 46 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013B Proiect: YANKO1204 Sample ID: 170256014 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 103 (25%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.47 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-013C 170256015 SE 09-AUG-06 25-AUG-06 Client 17.3%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth LC TPU MDA Units DF Analyst Date Time Batch Mtd Waived Actinium-228 Americium-241 U -Bismuth-212 Bismuth-214 Cesium-134 U Cesium- 137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -1.07-0.00337 0.808 0.614 0.0481 0.0789 0.074-0.0203-0.0129 0.0479 0.903 0.651-0.0163-0.022 12.9 0.614 0.00256 0.248+/-0.236+/-0.0367+/-0.311+/-0.118+/-0.0502+/-0.0569+/-0.0564+/-0.0622+/-0.0828+/-0.0527+/-0.0714+/-0.103+/-0.0298+/-0.0284+/-1.11+/-0.118+/-0.0199+/-0.0569 0.0703 0.034 0.157 0.0422 0.033 0.0226 0.0239 0.0547 0.0688 0.0529 0.0332 0.0431 0.0235 0.0226 0.250 0.0422 0.0177 0.0239+/-0.236+/-0.0367+/-0.311+/-0.118+/-0.0502+/-0.0569+/-0.0564+/-0.0622+/-0.0828+/-0.0527+/-0.0714+/-0.103+/-0.0298+/-0.0284+/-1.11+/-0.118+/-0.0199+/-0.0569 0.154 0.0701 0.341 0.0899 0.0699 0.0484 0.0531 0.115 0.152 0.109 0.069 0.0904 0.0506 0.0481 0.553 0.0899 0.0378 0.0508 0.0289 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/01/062118 563436 1 KSD1 09/07/06 1845 562563 2 0.00157 +/-0.0143 0.0123 +/-0.0143 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 48 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013C Proiect: YANKO1204 Sample ID: 170256015 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 98 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldoI-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.49 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-013D 170256016 SE 09-AUG-06 25-AUG-06 Client 25.9%Proiect: YANK01204 Client ID: YANKOOI Vol. Recv.: Units DF Analyst Date Time Batch Mtd Parameter Qualifier Result Uncertainty LC TPU MDA Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.03 +/-0.160 Americium-241 U 0.0216 +/-0.0981 Bismuth-212 0.420 +/-0.350 Bismuth-214 0.689 +/-0.0898 Cesium-134 U 0.0488 +/-0.0307 Cesium-137 0.170 +/-0.0491 Cobalt-60 0.566 +/-0.0694 Europium-152 U 0.0265 +/-0.0524 Europium-154 U 0.0628 +/-0.0639 Europium-155 U 0.0541 +/-0.0561 Lead-212 0.958 +/-0.0653 Lead-214 0.784 +/-0.0896 Manganese-54 U 0.00917 +/-0.0221 Niobium-94 U 0.0056 +/-0.019 Potassium-40 12.6 +/-0.931 Radium-226 0.689 +/-0.0898 Silver-108m U -0.00656 +/-0.0175 Thallium-208 0.314 +/-0.0426 Rad Gas Flow Proportional Counting 0.0664 0.0845 0.142 0.0339 0.0247 0.019 0.0198 0.0453 0.0591 0.0528 0.0265 0.0297 0.019 0.0164 0.166 0.0339 0.0151 0.0189+/-0.160+/-0.0981+/-0.350+/-0.0898+/-0.0307+/-0.0491+/-0.0694+/-0.0524+/-0.0639+/-0.0561+/-0.0653+/-0.0896+/-0.0221+/-0.019+/-0.931+/-0.0898+/-0.0175+/-0.0426 0.142 0.174 0.301 0.0715 0.0519 0.0402 0.0431 0.0946 0.127 0.109 0.055 0.0623 0.0403 0.0347 0.367 0.0715 0.0318 0.0398 0.0265 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/05/06 0521 563436 1 GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.00738 +/-0.0147 0.0112 +/-0.0147 KSD1 09/07/06 1846 562563 2 The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 Analyst Date Time Prep Batch LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 50 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-013D Project: YANKO 1204 Sample ID: 170256016 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 106 (25%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.51 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-005A 170256017 SE 09-AUG-06 25-AUG-06 Client 17.9%Project: Client ID: Vol. Recv.: YANK01204 YANKOOI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.975 Americium-241 U 0.0504 Bismuth-212 0.804 Bismuth-214 0.647 Cesium-134 U 0.0288 Cesium-137 0.249 Cobalt-60 0.682 Europium-152 U 0.0893 Europium-154 U 0.0167 Europium-155 U 0.00619 Lead-212 0.912 Lead-214 0.747 Manganese-54 U 0.0235 Niobium-94 U -0.00608 Potassium-40 10.5 Radium-226 0.647 Silver-108m U 0.00189 Thallium-208 0.322 Rad Gas Flow Proportional Counting GFPC, SO9O, solid-ALL FSS Strontium-90 U -0.00262+/-0.164+/-0.0306+/-0.393+/-0.112+/-0.0288+/-0.0491+/-0.0884+/-0.0683+/-0.0707+/-0.0524+/-0.0658+/-0.0939+/-0.0494+/-0.0244+/-0.910+/-0.112+/-0.0202+/-0.0462 0.0814 0.030 0.165 0.0371 0.0271 0.0255 0.0206 0.0526 0.0611 0.0476 0.0281 0.036 0.0228 0.0201 0.155 0.0371 0.0178 0.0209+/-0.164+/-0.0306+/-0.393+/-0.112+/-0.0288+/-0.0491+/-0.0884+/-0.0683+/-0.0707+/-0.0524+/-0.0658+/-0.0939+/-0.0494+/-0.0244+/-0.910+/-0.112+/-0.0202+/-0.0462 0.174 0.0616 0.351 0.0787 0.0574 0.0537 0.0453 0.110 0.134 0.0982 0.0584 0.0755 0.0486 0.0426 0.351 0.0787 0.0376 0.0442 0.0286 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/01/062119 563436 1 KSD1 09/07/06 1857 562563 2+/-0.0137 0.012 +/-0.0137 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 52 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005A Project: YANK01204 Sample ID: 170256017 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 92 (25/-,125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.53 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-005B 170256018 SE 10-AUG-06 25-AUG-06 Client 14%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS CAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.787 +/-0.187 Americium-241 U 0.0759 +/-0.0649 Bismuth-212 0.403 +/-0.233 Bisnmuth-214 0.636 +/-0.108 Cesium-134 U 0.0378 +/-0.0274 Cesium-137 0.181 +/-0.0421 Cobalt-60 0.710 +/-0.0716 Europium-152 U 0.0183 +/-0.0466 Europium-154 U 0.0204 +/-0.0516 Europium-155 UI 0.00 +/-0.0804 Lead-212 0.722 +/-0.086 Lead-214 0.832 +/-0.115 Manganese-54 U 0.0204 +/-0.0232 Niobium-94 U 0.0129 +/-0.0173 Potassium-40 9.30 +/-0.895 Radium-226 0.636 +/-0.108 Silver-108m U 0.0081 +/-0.0194 Thallium-208 0.299 +1-0.0505 Rad Gas Flow Proportional Counting 0.0725 0.0382 0.139 0.0306 0.0229 0.019 0.0155 0.0421 0.0449 0.0458 0.0317 0.0288 0.0192 0.0161 0.130 0.0306 0.0154 0.0157+/-0.187+/-0.0649+/-0.233+/-0.108+/-0.0274+/-0.0421+/-0.0716+/-0.0466+/-0.0516+/-0.0804+/-0.086+/-0.115+/-0.0232+/-0.0173+/-0.895+/-0.108+/-0.0194+1-0.0505 0.153 0.0789 0.294 0.0647 0.0482 0.040 0.034 0.0881 0.0982 0.0944 0.0651 0.0605 0.0406 0.0339 0.291 0.0647 0.0324 0.0332 0.0293 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 09/02/06 1713 563436 1 GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.0109 +/-0.0167 0.0123 +/-0.0167 KSDI 09/07/06 1857 562563 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 54 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005B Project: YANKO 1204 Sample ID: 170256018 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 95 (25%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.55 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-005C 170256019 SE 10-AUG-06 25-AUG-06 Client 24.6%Proiect: YANKO 1204 Client ID: YANKO0I Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamnnia,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.810 +/-0.116 Americium-241 U 0.0147 +/-0.0176 Bismuth-212 0.365 +/-0.171 Bismuth-214 0.623 +/-0.0633 Cesium-134 UI 0.00 +/-0.0297 Cesium-137 0.113 +/-0.0242 Cobalt-60 0.268 +/-0.0379 Europium-152 U -0.00617 +/-0.0317 Europium-154 U -0.0248 +/-0.0417 Europium-155 UI 0.00 +/-0.0407 Lead-212 0.840 +/-0.0404 Lead-214 0.686 +/-0.0505 Manganese-54 U 0.00306 +/-0.0143 Niobium-94 U 0.0053 +/-0.013 Potassium-40 10.2 +/-0.535 Radium-226 0.623 +/-0.0633 Silver-108m U -0.0071 +/-0.0113 Thallium-208 0.288 +/-0.031 Rad Gas Flow Proportional Counting 0.0431 0.0169 0.099 0.0212 0.0166 0.0124 0.012 0.0284 0.0337 0.0265 0.0162 0.0197 0.0127 0.0112 0.0857 0.0212 0.00971 0.0115+/-0.116+/-0.0176+/-0.171+/-0.0633+/-0.0297+/-0.0242+/-0.0379+/-0.0317+/-0.0417+/-0.0407+/-0.0404+1-0.0505+/-0.0143+/-0.013+/-0.535+/-0.0633+/-0.0113+/-0.031 0.090 0.0345 0.206 0.044 0.0343 0.0257 0.0254 0.0585 0.0714 0.054 0.0332 0.0406 0.0265 0.0232 0.186 0.044 0.0201 0.0239 0.0284 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/05/06 2143 563436 1 KSDI 09/07/06 1857 562563 2 GFPC, Sr9O, solid-ALL FSS Strontium-90 U 0.0082 +/-0.0158 0.012 +/-0.0158 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description 1 2 EML HASL 300, 4.5.2.3 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 56 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005C Project: YANKO 1204 Sample ID: 170256019 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 96 (25%-0125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.57 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: September 8, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-005D 170256020 SE 10-AUG-06 25-AUG-06 Client.19.1%Proiect: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth LC TPU MDA Units DF Analyst Date Time Batch Mtd Waived Actinium-228 Americium-2 4 1 U Bismuth-212 Bismuth-214 Cesium- 134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 UI Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-4 0 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting GFPC, Sr9O, solid-ALL FSS Strontium-90 U -0.995 0.0557 0.635 0.760 0.0627 0.503 1.72 0.00265 0,0538 0.00 1.09 0.802 0.0185-0.0168 10.7 0.760-0.021 0.343+/-0.411+/-0.0479+/-0.589+/-0.165+1-0.0504+/-0.0894+/-0.132+/-0.0988+/-0.114+/-0.119+/-0.126+/-0.135+/-0.0434+/-0.0366+/-1.11+/-0.165+/-0.0301+/-0.0887 0.146 0.0365 0.261 0.0601 0.0463 0.0338 0.0307 0.0745 0.0996 0.0591 0.0386 0.0517 0.0383 0.0309 0.276 0.0601 0.0247 0.0298+/-0.411+/-0.0479+/-0.589+/-0.165+/-0.0504+/-0.0894+/-0.132+/-0.0988+/-0.114+/-0.119+/-0.126+/-0.135+/-0.0434+/-0.0366+/-1.11+/-0.165+/-0.0301+/-0.0887 0.291 0.0729 0.521 0.120 0.0926 0.0676 0.0614 0.149 0.199 0.118 0.0772 0.103 0.0766 0.0618 0.551 0.120 0.0494 0.0595 0.0299 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 09/02/06 1725 563436 1 KSDI 09/07/06 1857 562563 2-0.00322 +/-0.0146 0.0127 +/-0.0146 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/27/06 1545 562444 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 EPA 905.0 Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits 58 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: September 8, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005D Project: YANKO 1204 Sample ID: 170256020 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 99 (25%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.59 I QUALITY CONTROL DATA 60 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client : Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: September 8, 2006 Page 1 of 5 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

170256 Parmname Rad Gamma Spec Batch 563436 QC1201171526 170256001 DUP Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 NOM Sample Qual QC Units RPD%REC% Range Anlst Date Time 0.966 1.01 pCi/g 4 Uncert: +/-0.192 +/-0.200 TPU: +/-0.192 +/-0.200 U 0.0375 U 0.0258 pCi/g 37 Uncert: +/-0.0387

+/-0.075 TPU: +/-0.0387

+/-0.075 0.366 0.592 pCi/g 47 Uncert: +/-0.306 +/-0.276 TPU: +/-0.306 +/-0.276 0.650 0.690 pCi/g 6 Uncert: +/-0.135 +/-0.0955 TPU: +/-0.135 +/-0.0955 U 0.0366 UI 0.00 pCi/g 56 Uncert: +/-0.0355

+/-0.035 TPU: +/-0.0355

+/-0.035 0.0666 0.0611 pCi/g 9 Uncert: +/-0.0355

+/-0.0415 TPU: +/-0.0355

+/-0.0415 0.104 0.159 pCi/g 41 Uncert: +/-0.0726

+/-0.0325 TPU: +/-0.0726

+/-0.0325 U 0.00636 U -0.00858 pCi/g 1350 Uncert: +/-0.0728

+/-0.0624 TPU: +/-0.0728

+/-0.0624 U -0.0788 U 0.00919 pCi/g 253 Uncert: +/-0.0938

+/-0.0602 TPU: +/-0.0938

+/-0.0602 U 0.0672 U 0.0817 pCi/g 20 Uncert: +/-0.0554

+/-0.0557 TPU: +/-0.0554

+/-0.0557 0.871 0.847 pCi/g 3 Uncert: +/-0.0971

+/-0.0867 TPU: +/-0.0971

+/-0.0867 0.727 0.699 pCi/g 4 Uncert: +/-0.105 +/-0.102 TPU: +1-0.105 +/-0.102 U -0.00916 U -0.00665 pCi/g 32 Uncert: +/-0.0319

+/-0.0225 TPU: +/-0.0319

+/-0.0225 U 0.0101 U -0.00339 pCi/g 402 Uncert: +/-0.0244

+/-0.0176 TPU: +/-0.0244

+/-0.0176 (0%- 100%) MJHI 09/02/06 17:26 (0% -100%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -100%)(0% -100%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -20%)(0%-20%)(0%- 100%)(0%- 100%)61 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170256 Page 2 of 5 Parmname NOM Samole Oual OC Units RPD%REC% Rane AnIst Date Time.Rad Gamma Spec Batch 563436 Potassium-40 Radium-226 Silver-] 08m Thallium-208 11.3 Uncert: +/-0.986 TPU: +/-0.986 0.650 Uncert: +/-0.135 TPU: +/-0.135 u -0.0067 Uncert: +/-0.0208 TPU: +/-0.0208 0.283 Uncert: +/-0.0618 TPU: +/-0.0618 Actinium-228 Americium-24 I LCS Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.58 Uncert: TPU: 14.5 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 11.7+/-1.03+/-1.03 0.690+/-0.0955+/-0.0955 U 0.000104+/-0.018+/-0.018 0.283+/-0.048+/-0.048 U 0.254+/-0.565+/-0.565 24.1+/-1.28+/-1 .28 U 0.575+/-0.944+/-0.944 U 0.0248+/-0.213+/-0.213 U 0.00032+/-0.147+/-0.147 9.84+/-0.487+/-0.487 14.7+/-0.660+/-0.660 U 0.125+/-0.292+/-0.292 U 0.0779+/-0.277+/-0.277 U -0.0876+/-0.277+/-0.277 U 0.0524+/-0.155+/-0.155 U -0.103+/-0.212 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 09/03/06 22:31 pCi/g 3 pCi/g 6 pCi/g 206 pCi/g 0 103 (75%-125%)

(0% -20%)(0%- 100%)(0%- 100%)(0%- 100%)103 (75%-125%)

101 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-2I4 Uncert: 62 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn QC Summary Workorder:

170256 Page 3 of 5 REC% Ran2e Anist Parmname NOM Sample Oual OC Units RPD%Date Time Rad Gamma Spec Batch 563436 TPU: Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 QCI201171525 Actinium-228 Americium-241 MB Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.212 U 0.0306+/-0.135+/-0.135 U -0.0513+/-0.115+/-0.115 U 0.769+/-1.10+/-1.10 U 0.0248+/-0.213+/-0.213 U 0.0782+1-0.105+1-0.105 U 0.180+/-0.177+/-0.177 U 0.0216+/-0.0479+/-0.0479 U -0.0654+/-0.0396+/-0.0396 U 0.110+/-0.0705+/-0.0705 U 0.00843+/-0.0317+/-0.0317 U -0.00203+/-0.012+/-0.012 U -0.00757+/-0.0117+/-0.0117 U -0.00589+/-0.0128+/-0.0128 U -0.0169+/-0.0308+/-0.0308 U 0.00802+/-0.0305+/-0.0305 U -0.00342 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%- 125%)09/02/06 17:16 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-I152 Europium-154 Europium-155 63 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170256 Page 4 of 5 QC Units RPD% REC% Range Anist Date Time Parmname NOM Sample Qual Rad Gamma Spec Batch 563436 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver- 108m Thallium-208 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.0294+/-0.0294 U 0.0151+/-0.028+/-0.028 U 0.00738+/-0.0252+/-0.0252 U 0.0127+/-0.0111+/-0.0111 U -0.00293+/-0.012+/-0.012 U 0.112+/-0.173+/-0.173 U 0.00843+/-0.0317+/-0.0317 U 0.00354+/-0.0115+/-0.0115 U -0.011+/-0.0157+/-0.0157 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Rad Gas Flow Batch 562563 QC1201169422 170256002 DUP Strontium-90 QC1201169424 LCS Strontium-90 QC1201169421 MB Strontium-90 QC1201169423 170256002 MS Strontium-90 U 0.00501 Uncert: +/-0.0149 TPU: +/-0.0149 U 0.00534+/-0.0155+1-0.0155 1.57+/-0.140+/-0.147 pCi/g 0 (0%- 100%) KSDI 09/07/06 18:59 1.74 Uncert: TPU: Uncert: TPU: 1.74 U Uncert: TPU: U 0.0172+/-0.0185+/-0.0185 pCi/g pCi/g pCi/g 90 (75%-125%)

09/07/06 19:16 09/07/06 18:59 09/07/06 19:16 0.00501+/-0.0149+/-0.0149 1.32+/-0.124+/-0.130 76 (75%-125%)

Notes: The Qualifiers in this report are defined as follows: 64 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

170256 Page 5 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded I Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.** Indicates analyte is a surrogate compound." The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.65 General Narrative Page 1 of 105 CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 168404 SDG: MSR #06-0652, 06-0675, 06-0687, 06-0688, 06-0707, 06-0743, 06-0755 August 15, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8.171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on May 5, May 9, May 12, May 17, May 26, June 2, June 8, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)Page 2 of 105 Phone (843) 556-8171
  • Fax (843) 766-1178
  • www.gel.com 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F Items of Note: At the request of Dale Randall on July 20, 2006, GEL analyzed the above samples according to the spreadsheet in the attached email.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Seven soil samples were reanalyzed for FSSALL, except gamma and Sr-90.Four soil samples were reanalyzed for FSSALL, except gamma and Ni-63.Two soil samples were reanalyzed for FSSALL, except gamma.Two soil samples were reanalyzed for FSALL, except gamma, Sr-90 and Ni-63.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.PO. Box 30712

  • Charleston, SC 29417 -2040 Savage Road (29407)Phone (843) 556-8171
  • Fax (843) 766-1178
  • www.gel.com Page 3 of 105 I I !

Additional HTD analyses

Subject:

Additional HTD analyses From: "Dale Randall" <randall @cyapco.com>

1(.,gLi(oc, 'Date: Thu, 20 Jul 2006 11:04:54 -0400 To: "Cheryl Jones" <cj @gel.corn>

CC: "Clyde Newson" <Newson@CYAPCO.com>, "John McCarthy" <McCarthy@

CYAPCO.com>

Cheryl: Per our earlier discussion, attached is a list of samples that we would like to have analyzed to the FSSALL protocol.

I have included a list of test protocols performed on each sample to date. Once you have had an opportunity to determine our options for each sample please call or e-mail me at your convenience.

Thank You, Dale (860) 267-3133 Content-Description:

GEL FSSALL analyses request.xls GEL FSSALL analyses request.xls Content-Type:

application/vrid.mns-excel

'Content-Encoding:

base64 Page 4 of 105 I of I 8/2/2006 7:04 PM Done To be done Previous GEL ID CY sample location IDs FSS Gam Sr-90 Ni-63 Am Pu Sr9O Pu241 Fe55 N163 Tc99 H3 C14 C 164220008 9106-0002-007F x x x x x x x x x x 164220012 9106-0002-o011F x x __x x x x x x x x o 162335004 9106-0003-004F x x x x x x x x x x 162335014 9106-0003-015F x x x x x x x x x x 162832015 9106-0004-005F x x x x x x x x x x 162832009 9106-0004-015F x x x x x x x x x x 162485008 9106-0005-01OF x x x x x x x x x x 162485011 9106-0005-014F x x x x x x x x x x 162850014 9106-0006-005F x x x x x x x x x x 163741005 9106-0008-006F x x x x x x x x x x 163741009 9106-0008-008F x x x x x x x x x x 164542008 9106-0009-002F x x x x x x X x x x 164542003 9106-0009-017F x x x x x x x x x x 163105009 9106-0010-001iF x x x X- x x x _ X Xx 163105016 9106-0010-012F x x x x x x x x x x Chain of Custody and Supporting Documentation Page 6 of 105 Health Physics Procedure ffo 5qolýGPP-GGGR-R5104-003-Attachment B-CY-001 Major-t (b C Chain of Custody Form Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 No. 2006-00371 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones c M 4 Priority:

Z 30 D. [] 14 D. [] 7 D. Container c ft Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-OOIF 5/17/06 10:42 SE C BP X X .Transferred fromn COC 2006-00357 9106-0002-002F 5/18/06 09:43 SE C BP x Transtrred from COC 2006-00361 9106-0002-003F 5/18/06 10:14 SE C BP x x Transferred fror COC 2006-00361 9106-0002-004F 5/18/06 10:39 SE C BP x x -"Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP x x Transferred from COC 2006-00364 9106-0002-006F 5/18/06 13:14 SE C BP X _ x Transferred fron COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP x --Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:37 SE C BP X Transferred from COC 2006-00364 9106-0002-008F 5/18/06 14:04 SE C BP X X" Transferred from COC 2006-00364 NOTES: PO #: 002332 MSR #: 06- SSWP# NA U LTP QA [I Radwaste QA El Non QA Samples Shipped Via: Internal 07 55 Z Fed Ex Container'l UPS Temp.: Deg. C El Hand Custody Sealed?DRel qDate/Time

2) l ived By Date/Time Custody Seal 1 8 ý-- h% (o C\ý1.E Other Intact?ty-gelin-quished iy Date/Time
4) Received By Date/Time YO No Bill of Lading #5) Relinquished By Date/Time
6) Received By Date/Time 790 1 Y/IZa6 571/____........__________________________

Health Physics Procedure GPP-GGGR-R5104-003-Attachmnent B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003 -Attachment B-CY-O0 1 Major 00 0o Chain of Custody Form No. 2006-00372 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones EC/ Cn Priority:

Z 30 D. [] 14 D. E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Commen, Preservation Lab Sample ID 9106-0002-009F 5/18/06 14:28 SE C BP x Transferred from COC 2006-00364 9106-0002-01 OF 5/18/06 14:50 SE C BP x -x -Transferred from COC 2006-00364 9106-0002-011F 5/19/06 08:10 SE C BP X X Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP x x Transferred from COO 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP X -X Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP X x Transferred from COC 2006-00365 9106-0002-014FS 5/19/06 09:58 SE C BP X x Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:29 SE C BP X Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP X x Transferred from COC 2006-00365 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA [ Radwaste QA El Non QA Samples Shipped Via: Internal S Fed Ex Container UPS Temp.: Deg. C Q Hand Custody Sealed?I ýRelin ihe Date/Time

2) Redived By Datg/Time Custody Seal l .b-/,*)¢, ....I__ Other Intact?3)"relinquished By Date/Time
4) Received By Date/Time BillofLading#YO NO Bill of Lading #5) Relinquished By -Date/Time
6) Received By ""Date/Time 7qoQ "/Ii 7i57ic?

Connecticut Yankee Statement of Work for Analytical Lab Services-CY-ISC-SOW-O01 Figure 1. Sample Check-in List Date/Time Received:

(0 ~ t SDG#: 1;,. 0- 0 --46ý5 Work OrderNumber:

__ C. '-2-0".Shipping Container IDYIC t 4 6 5 9,/ s1/0 Chain of Custody# 4 ' -C# '2i 1. Custody Seals ori shipping container intact?. Yes. No [ ]2. Custody Seals dated and signed? Yes No [].3. Chain-of-Custody record present? Yes No[4. Cooler temperature 2 _ -5. Vermiculite/packing materials is: Wet [ ] Dry [ l] f f "1 6. -Number of samples in shipping container:

7. Sample. holding times exceeded?

Yes [ No0'$//8. Samples have:-tape -hazard labels_4-custody seals _____appropriate sample labels 9. Samples are.'--) in good condition -leaking-broken -have air bubbles 10. !Were any anomalies identified in sample receipt? Yes ['] NoX]11. I..Description ofanomalies (include sample numbers): Sample. Custodian/Laboratory:

K ,' j Date= (a J-" Telephoned to: -On By , Page 9 of.:105 Connecticut Yankee Statement of Work for Analytical Lab Services 4 \-Cy-IsCso-SOol0 Figure 1. Sample Check-in List Datefrime Received', ,a SDG#: )- -Work Order Number: 1(.¢AZW 7'Shipping Codntainer ID1101 q N5 .S. W Chain of Custody#2vV (1 0 9.q 1. Custody Seals ori shipping container intact?. Yes No 2. Custody Seals dated and signed? Yes No[3. Chain-of-Custody record present? Yes/J No []4. Cooler temperature

5. Vermiculite/packing materials is: Wet [ Dry t, I 6.: Number of samples in shipping container:

..-7. Sample holding times exc'eeded?

Yes [ ]No..8. S I e.h I. S r~ les have :_tape -hazard labels custody seals -appropriate sample labels 9. Samples are-.lngood condition .jeaking.broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes f I No 11. .Description of anomalies (include sample numbers): Sample Custodian/Laboratory:

t Lb f Date: 6 "o b Telephoned to: On 0By Page 10 of:105 :.

SAMPLE RECEIPT & REVIEW FORM 0IN-OR10' PM use only I IClient: (1,cxinpQ4, 1 rju '(.a k e.SDG/ARCOC/WorkOrder:

Date Received:

PM(A) Review (ensre non-conforming items are resolved prior to signing);Received By: Sample Receipt Criteria i CommentslQualifiers (Required For Non-Conforming Items)I Shipping containers received intact circle Applicable:

seals broken damaged comainer I conainer other (describe) and sealed? 7 Samples requiring cold Circle Coolant # ice bags blue ice / dry ice none other describe)2 preservation within (4 +/- 2 C)?Record preservation method.Chain of custody documents included with shipment?4 Sample containers intact and Circle Applicable:sdls broken damaged container leaking container other (describe) sealed? -" 5 Samples requiring chemical & p6 WD's. containers affected and observed pH: preservation at proper pH?-V J C , A tn ., I v -A I l r 6 (defined as < 6mm bubble)?aaunpl eu s ainm containers ariccted: i= I * , I 7 Are Encore containers present?(If yes, immediately deliver to VOA

= _I1 Smes received olding time?9 Sample ID's ICOC match ID's on bottles?1-0i j" N's - If-a ts a IeQ: "IF S 31113 affectie: 1 I 0 Date &/me on COC match date& tirv6 on bottles?I*I , Ntber Of Containers received match number indicated on COC?J 9-Sample ID's affected: Sample ID'S affected: 12 COC form is properly signed in relinquished/received sections?I I C":L 2,00( +1 14 Air Bill Tracking #'s, &Additional Comments m-h £RSO RAD Receipt #Suspected Hazard Information

  • If> x2 area background is observed on samples identified as "nom-Z co regulated/non-radioactive", contact the Radiation Safety group for further ARaolo al Classificaion?

-investigation.

A 1Ra gcalasictn

.Maximnum Counts Observed*:

4P B Comments: lihipped as DO ITHazardou IdMaterial?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. N#: PM (or PMA) review of Hazard classiticatioll-m r i Page 11 of 105 V/

-SSML RECEIPT & REVIEW FORM PM use only[Client:onr!iu T" (cC' SDG/A RCOC/Work Ordler:_/.4Z vDate Received:

C, -jO, 0 pM(A) Review (I re non-cfnror g i are resolved prior to signing): IlReceived By: Sample Receipt Criteria Comments/Qualifiers equired for Non-Conforming Items)1 Shipping containers received intact Circle Applicable:

seals broke damaged container leaking container other (describe) and sealed? /Samples requiring cold Circle Coolant # 71 ags blue ice dry ice none other describe)2 preservation within (4 +/- 2 C)? /Record preservation method. /Chain of custody documents included with shipment?Sample containers intact and Circ pplicable:

seals broken damaged container leaking container other (describe) sealed? ____5 Samples requiring chemical Sample Is. containers affected and observed pH: preservation at proper pH?6 VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

__.Samples received within hold ini Id's and tests affected;time?9 Sample ID's on COC matc: ID's Sample ID's and containers affected: on bottles? ýK Date & time on COC tch date Sample ID's affected:& time on bottles?1Number of containee received Sample ID's affected: I match number indic/ted on COG?COC form is proldrly signed in 44--12relinquished/recpived sections?

Cc'C- Z.oO(s bp Air Bill ,Tracking

  1. s, &Additional Comments GJ U ~RSO RAD Receipt #___ __________

Su e H r c *If > x2 area background is observed on samples identified as "non-S regulated/non-radioactive", contact the Radiation Safety group for further r investigation.

A adiological Classification.

?aximur Counts Observed: CB Regulated?

' t Comments:[Shipped as DUI Hazardlu cMaterial?

If yes, contact Waste azard Class Shipped: r Manager or ESH Manager. N#: PM (or PMA) review of Hazard classitication:

Initials-Date: 0-Page 2 of 05 !Page 12 of 105 (J Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 1 Major Chain of Custody Form Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 , 860-267-2556

/C / 0,.,' ' +.~~~~~~ L a b U se O n ly ..: :. .....Project Name: Haddam Neck Decommissioning Analyses Requested Lab.Use"O..y Contact Name & Phone: ,Comments-.

Jack McCarthy 860-267-2556 Ext. 3024..Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 .843 556 8171. Attn. Cheryl Jones Cn'Priority:

Z 30 D. [] 14 D. f 7 D. Container Sample Size- ....._*_... .___._-_-___

Media Type &Type Comment, Preservation Lab I Sample Designation Date Time Code Code Code -o-mTransferred from C oC2006-00221 Sample 9106-0003-OOIF 4/24/06 14:13 SE C BP X i 9106-0003-002F 4/24/06 14:39 SE C BP X Transferred from COC2006-00221 p$) 9106-0003-002F 4/24/06 15:01 SE C BP X Transferred from COC2006-00221 9106-0003-003F 4/24/06 15:01 SE C BP X Transferred from C0C2006-00221 9106-0003-004F 4/25/06 08:41 SE C BP X Transferred from COC2006-00223 9106-0003-004FS 4/25/06 08:41 SE C BP X Transferred from COC2006-00223 t 9106-0003-005F 4/25/06 09:21 SE C BP x Transferred from COC20O6-00223

.9106-0003-006F 4/25/06 09:46 SE C BP X Transferred from COC2006-00223 9106-0003-007F 4/25/06 10:28 SE C BP -Transferred from COC2006-00223 91I06-0003-008F 4/25/06 11 :15 SE C BP Tr sf refomC 206 023 +". .fi.... ":. , :" ,. -..NOTES: PO #: 002332 MSR #: 06-° SSWP# NA U LTP QA El Radwaste QA El Non QA Samples Shipped Via: .Inten Cifc.irier Combined samples 9106-0003-003F taken on 4/25/06 @08:19 and 9106-0003-003FB taken on 4/25/06 @ 08:19 in order to have sufficient sample for counting.

N Fed Ex ! .:L.. D.eg C : El UPS El Hand 6 ! Custody Sealedd?, 1) Relinquished By Date/Time By D Dat7 Time :CistodY Se adly at?, "' " ', E, Other D.,:a. E. .7,, N:" !3) Relinquished By Date/Tim e 4) Received By Dat e/Tim e _,_.. ..'__.__..__.

Bill of Lading #5) Relinquished By Date/Time

6) Received By Date/Time

.:

2 *, .

Health Physicis Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Chain of Custody Form No. 2006-00313 Project Name: Haddam Neck Decommissioning Analyses Requested W My.Contact N am e & Phone: ..... '; ': Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State) ..... ..General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 <843 556 8171. Attn. Cheryl Jones r 1 .Priority:

Z 30 D.El 14 D.[] 7 D. Container Sample Size-Media Type &Type Sample Desigation Date Time Code Code Code Comment, Preservation U .am 9106-0003-009F 4/25/06 13:00 SE C BP X Transferred from COC 2006-00236

.0 9106-0003-010F 4/25/06 13:23 SE C BP X TransferredfromCOC2006-0026 , .010 9106-0003-010FS 4/25/06 13:23 SE C BP X Transferred from CO( 2006-00236

.9106-0003-012F 4/25/06 15:12 SE C BP X jTransferred from COC 2006-00236 0%1 9106-0003-013F 4/25/06 14:21 SE C BP x Transferred from COC 2006-00236 0j'L 9106-0003-014F 4/25/06 14:48 SE C BP x Transferred fromCOC 2006-00236

'.' ----Transferred from COC 2006-00237 o6 9106-0003-015F 4/26/06 08
16 SE C BP X Transferred from COC 200--"0236

"...........

9106-0003-016F 4/26/06 09:41 SE C BP X Transferred from COC 2006-00237 9106-0003-017F 4/26/06 09:18 SE C BP X Transferred from COC 2006-00237 9106-0003-017F 4/26/06 09:9 SE IC BP X Transfered from COC 2-06-00237.

'619106-0003-01 8F 4/26/06 08
59 SE IC _ BP x Transferred from COC 2006-00237

'NOTES: PO #: 002332 MSR #: 06- or, S2-SSWP#NA Z LTP QA El Radwaste QA E] Non QA 1) Relinquished By Date ime 2) eceived By at Time 3) Relinquished By Date/Time

4) Received By Dafe/Time Samples Shipped Via:[ Fed Ex ElUPS I] Hand El Other Bill of Lading 4 7k c2o-, 012,7- o0d t 2 Stbd~ 4intact?

Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-OO1 Figure 1. Sample Check-in List Date/Timne Received:

1t.ý/$,5/O(1 (016 SDG#: M.. 6&tI O d.Work Order Number: I t,"Z- 3 .Shipping Cdntainer ID: IG1 916 7-Cjl 0 I Chain of Custody# # O 63'%J"...1. Custody Seals od shipping container intact?.-

Yes [ ] No 2. Custody Seals dated and signed? Yes [ J. No .A '3. Chain-of-Custody record present? Yes No[].4. Cooler temperature

.) C]5. Vermiculite/packing materials is: Wet [ / Dry[ / '-6. Number of samples in shipping container:

[ W ./ []DI C' .]7- Sample holding times exceeded?

Yes [ No.8. Sampl ,...-tape -hazard labels_Z custody Seals -appropriate sample labels 9. Samples are: good condition

.'Ieaking-__broken

." have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ ] No 11. .Description of anomalies (include sample numbers): Sample Custodian/Laboratory:_ (L C) ( ("ecf. c, Datez. "/7 2 ' " Telephoned to: On By.Page 15 of 105'I 0 SAMPLE RECEIPT & REVIEW FORM r I'Mme only i a2 13 35r Date, Received:

14M(A) R (eusure non-co items a resolved prior to signing): Received By: C (, J C a Sample Receipt Criteria Z Z Comments/Qualiriers (Required for Non-Conforming Items)IShipping containers received intact Circle Applicable:

seals broken datmaged container leaking container odr (descrilx)

'and sealed? , --_Samples requiring cold Circle Coolant # ice bags blue ice dry icc none 2 preservation within (4 +/- 2 C)?IRe__ dreservation method. / P e &toit-Chain of custody documents included with shipment?4 Sample containers intact and Circle Applicable:

seal broken damaged container leaking container oaher(describe) sealed?Samples requiring chemical Sample ID's. containers affected and observed pH: reservation at proper pH?VOA vials free of headspace Sample ID's and containers affected: (defined as < 6rm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

....__Samples received within holding Id's and tests affected: time?9 Sample ID's on COC match ID's Sample ID's and containers affected: on bottles?Date & time on COC match date Sample ID's affected:& time on bottles?Number of containers received Sample ID's affected: match number indicated on COC?COC form is properly signed in relinquished/received sections?

_ _.._ _ __ _14 Air Bill ,Tracking

  1. 's, & q .d C '--Additional Comments I It OV-a V RSO RAD Receipt#Suspected Hazard Information
  • If > x2 area background is observed on samples identified as "non-St w regulated/non-radioactive", contact the Radiation Safety group for further__ 9 investigation.

A 1Rad* gical Classification?

Maximum Counts Observed*:

i TPCH Regulated Comments: Shipped as DOI Hazardous Ci Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager.1 UN#: PM (or PMA) review of Hazard classification:

Initials L 16 , Date: 0 (, Page 16 of 105 (/01 1 I I, Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003 -Attachment B-CY-O() 1 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 IýProject Name: Haddam Neck Decommissic

Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

0 30 D. [] 14 D. [] 7 D.Samples Shipped Via: 9 Fed Ex Dl uPs nl Hand El Other Bill of Lading #

Health Physs Prbedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major

  • "C~ut~t Yankee Atomic Power Company I-. '6jun Hollow Road, East Hampton, CT 06424 860-267-2556)ject Name: Haddam Neck Decommissioning Contact Name & Phone: Jack McCarthy-'

860-267-2556 Ext. 3024 Analytica!

Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

Z 30 D. [] 14 D. F] 7 D.Samples Shipped Via:[ Fed Ex E UPS[] Hand LI Other Bill of Lading 4 Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/l'imc Rcceived: .I- /,. 0 G SDG#: /X, R L',,- o, F4 Work Order Number: /- 2 '/Shipping Container ID: "qjq 335- 8812 1.. Custody Seals on shipping container intact?2. Custody Seals dated and signed?3. Chain-of-Custody record present?4. Cooler temperature

5. Venniculite/packing materials is: 6. Number of samples in shipping container:
7. Sample holding times exceeded?Chain of Custody # aoo 0 1 -6 O,.7 -I Yes No [ ]Yes No []Yes No [3 Wet g Dry [Ycs [I No 8. Samples have:-I'_tape -hazard labels_t custody seals appropriate sample labels 9. Samples are:_ in good condition

_4-_leaking broken have air bubbles 10. Were any anomalies identified in sample receipt? Yes No [3 11. Description of anomalies (include sample numbers): Sample Custodian/Laboratory:

Zýýt Telephoned to: Date: /.?.I (I. 'a..po I -On -BY-__w-Page 45 of 56 Page 19 of 105

" Connecticut Yankee Statemnt of Work for Lab Services CY-ISC-SOW.O0 Figure 1. Sample Check-in List .Dawne erecxivc O2X SDG# .JOG4 Work Order Number. Ivt .-*I_" SShipping C"tainer w ,.- & Chain of Cu AF)Oo".* .CsoySasaihwppng container intact?. Ye[No$2. CustoSeals dated and signed? Yes-[ jNof 3. Chiof-CUsty recordPresent?, Ycs N 4. Cool. wiperataw S. arnicu~ite/P3Cjd~g rnaezials -is: 'Wet ~Dlyt\7 -Sa le holding td " .Y.s[."oU 8. Sampleshae-A~4custody se Appropzate sample labels 9. Samples arm:.ngood cozlition 2Jein.-.......

....:

air bubbles 10. Werem ny eoinfl YeS*. .D Yes N'o'-; *" " ta" 's(1qud " "be*)S~ampCsdvjp~.(,v

,..* .".. .c , ,o._______...

__________O Page 20 of 105' I 1t, 8 SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM-AZ qqF~gf)- (DID?)?) A_ _ _ _ _ m1~ Se.i-pe (D o :)k (- .,0--(Qnl ro( -00330 C (o") h" biq. g 3~5 CL rro n\xo(> ~r b.s- -a 1C 6 C 2 c \__ _* cGO ) ,4.pS J'Page 21 of 105 I III SAMPLE RECEIPT & REVIEW FORM PM use only Client: CO- Y A-11-.- .- SDGIARCOC/Work Order: 1/( T93Z-Date Received:

C F, -jPM(A) Review (ensire fon-coniorming items are resolved prior to signing)-eceived BY: l_____________

_____Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items)1 Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (describe) 1and sealed? -I Samples requiring cold Circle Coolant # ice bags blue ice dry ice ROMe other decribe)2 preservation within (4 + /- 2 C)?Record preservation method.--_

_ _-_--Chain of custody documents included with shipment?

C cnee SSample containers intact and A seals broken damaged container I n other(descr sealed? -* @l Ap op-ooo.1k.

ll.Samples requiring chemical "" mpte is. eontaine-, affected and observed pH: Srervation at proper pH?VOA vials free of headspace Sample ID's and containers affected: 6 (defined as < 6mm bubble)?___

Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

__, Samples received within holding Id's and test affected: 8 time? __, Sample ID's on COC match ID's 1Sape IDys and comaineM affected: on bottles? , 10 Date & time on COC match date Sam 'ID' affected:& time on bottles? __._,, Number of containers received 1 Sam* e'satcted:

1match number indicated on COC?COC form is properly signed in relinquished/received sections?

1 _( oc. x. i0 r , , Air Bill ,Tracking

  1. 's, &14 Additional Comments~~ ~ ORADkReceipt#

__________

o *If > x2 area background is observed on samples identified as .'n-Suspectedd.

-. nnregulated/non-radioactive', contact the Radiation Safety group forfturther A Radipoioca C*

  • sicv-0n.n.

i PUB Regulatedl?

I -pped as. I Hzardous .C Material?

If yes, contact Waste"Manager or ESH Manager. Y , -u' MMYC 'J~s: ~.MI --b:omments: lazard Claw Shipped: /*Initials Date: 7-h 7/-Z rPi099t!ýfr

~yj'.w of Hazard classification:

SAMPLE RECEIPT & REVIEW FORM PhM 0 only Client: vrnb~b ~SDG/ARCOCIWorJi Orde; /67-r97-2,j Date Received:.

PM(A) Rev lew 2 2 frl IS wre resolved piow to sigaing):

1 Received By: " .. .. c ' r_.. .._* ....Sample Receipt Criteria >0 z Z Comments/Qualfimrs (Required for NouuConforming Items)1 Shipping containers received intact Circle Applicable:

seals broken damaged container leaking conmain odher (describe) and sealed? Circle Coolant _ icebags _ blueice _ dryicedescribe)

Samples requiring cold Circle COi I ie bags blue --e dry ie dr dcr)2 preservation within (4 +/- 2 C)?-Record preservation method. -Chain of custody documents c~gi, w tA-included with shipment?

...... " t V-SSample containers intact and ic~l~1PiC-k biC5Cuclsbf en damaged container Icaking continerk oadcrit : sealed? I.ampte I VO \t. -1117 qr n Samples requiring chemical Sample IDa. containers affected and observed pH: preservation at proper pH? ........ .VOA vials free of headspace Samle ID's and colainein affected: 6 (defined as < 6mm bubble)? ._._..=Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)__

Samples received within holding Ida's and tests affected: time?Sample ID's on COC match ID's San ID's ad conainers affeted: 9 on bottles?Date & time on COC match date Sample to's affected: 10& time on bottles?11Number of containers received Sml DS2lCd match number indicated on COC?COC form is properly signed in Yfl CbC. "Y't, ri 11 relinquished/received sections?14 Air BIl ,Trcking #'s, & SU 1 ~ -c Stt-Additional Comments SRSO RAD Recipt_#A -f > x2 areabackground is observed on samples identified as *non-Suspected Hazard Information Z regulated/non-radioactve'.

contact the Radiation Safety group for firther tavc We investigation.

RAdiological Classification?

Maximum Counts Observed*:

rinpped as VtO Hazardous Material?

If yes, contact Waste V, Hazard Class Shipped: Jmanager or ESH Manager. i UN//: PM (or PMA) review of Hazard classification:

Initials Date: .U Vj Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 iect Name: Haddam Neck Decommissionina I Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

M 30 D. [] 14 D. El 7 D.Samples Shipped Via:[ Fed Ex UPS E' Hand El Other Bill of Lading #7qzi- ?9I9

..,C o n n ecticut Y an kee -C Y -isc -SO W -O0 1 Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List.Date/Time Receiv :_ 4' 0 3*SDG#W ork Order Number: .. .03 I.Shipping Co'ntainer ID" J%!, Chain of Custody# _I g 0 c 9.-C ustody Seals oii shipping container intact? _ Y es N o ]2. C ustody Seals dated and signed? .Y es' ..N o [ ]3. Chain-of-Custody record prýsent? Yes J4 No I ].4. Cooler t-mperature

.If ,, I " 5. Vermiculite/packing materials is: Wet W.'Dry J%.6.' .Number ofsamples in shipping container:

.._7. Sam ple holding tim es exceeded?

." Y es ]N o.8. Samples have: tape htazard labels*J-. _custody seals -appropriate sample labels 9.Samples are: j__n good condition -Zleaking(vte-

)-broken ' -have air bubbles 10. Were any anomalies identified in sarnple receipt? Yes []No [4'* 1.. .Description of anomalies (include sample numbers):*an p e , , ..va b o r t o tTeeph o:__ _ __ _ _ to*_-Page 25 of 105.

SAMPLE RECEIPT & REVIEW FORM PM use only Client: I 1SDG/ARCOC/Work Order: IG Z-85 Date Received:

JL PM(A) Review (ensure ao-confo items are resolved prior to signing): Received By: (f r 1 4 K Sample Receipt Criteria Z Comments/Qualifiers (Required for Non-Conforming Items)Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (describe) a"ksealed?

Samp requiring cold Circle Coolant # ice bags blue ice dry ice none other describe)2 preservati within (4 +/- 2 C)?.RecorTd preserv on method. __________________________

Chain of custody d nts 3-included with shi ment?4 Sample containers intact and Circle Applicable:

seals broken damaged container leaking container other (describe) sealed? .. ...5 Samples requiring chemicalSample ID's. conainers affected and obeved pH: ,preservation at proper pH?6VOA vials free of headspace Sample ID's and containers affected: 6 (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

AI 8 Samples received within holding Id's and tests affected: time?9oSample ID's on COC match ID's Sample ID's and containers affected: 10Date & time on COC match date Sample 11D's affected:" ....1 & time on bottles?Number of containers received Sample ID's affected: match number indicated on COC?COC form is properly signed in 12 relinquished/received sections?14 Air Bill ,Tracking

  1. 's, & -i [ " g'" ]7 ..Additional Comments 8 -I PC V RSO RAD Receipt #_____ _______i S *gf > x2 area background is observed on samples identified as "non-Suspected uazaru Informnation z Z-- regulated/non-radioactive", contact the Radiation Safety group for further W F investigation.

SlRadiological Classification?

7 Maximum Counts Observed*:

PCB Regulated?

Comnments:

Shipped as Dt tHazardous

[Hazrd Class Shipped: C Material?

If yes, contact Waste HzrCs Manager or ESH Manager.PM (or PMA) review of Hazard classification:

Iniials C Date: 77 ""-- V........I G/

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-0O 1 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424.860-267-2556 iroject Name: Jladl0am NecJK tecommissicName & Phone: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

Z 30 D. Ml 14 D. M] 7 D.Samples Shipped Via:[ Fed Ex El UPS El Hand[] Other Bill of Lading #_7 o.970 f- 17-00 Connecticut Yankee Statement of Work for Analytical Lab Services-CY-Isc-.Sow-o0l Figure 1. -Sample Check-in List Date/lime Received=AX 5 (0 Work Order N um ber _/.-_ _ _--_ _.Shipping Cdhtainer ID: ((Qt, 5 1 N2(t Chain of Custody# "E i s-'--1. Custody Seals. onshipping container intact?.. -Yes.[ 2. Custody Seals dated and signed? Yes[j I No 3. Chain-of-Custody record present? Yes.No CI]A .Cooler ..emperatu..e

5. Vermiculite/packing mateials-is:

Wet F Dry ', J 6.' Number ofsamples in shipping containr (- pf.7. Sample holding Limes Cxceeded?

.Yes [Not4).8.. Samples have:.J~tapehazard labels--t-usoyseals -appropriate sample labels 9. Samples ae:-gX in Rood condition leaking-broken -" have air bubbles 10. Were any anomalies identified in samp. ! recipt? Yes No II.. Description of anomalies (include sample numbers):

,"l .C us to di.,,/L b t _ a ,- --.*y " -'--- DIate --.Telepphoned tO: *0'" "_.Page 28 of 105.'I 11ý

/ SAMPLE RECEIPT & REVIEW FORMme eoly Client: .. nO -, JSDG/ARCOC/Work Order: ( szr8-, /6,Z",, Date Received:

=5- P". i(A) Revilew (esre noo-conor mifn ItoElU we resolved prior to signing): Received By: C t-wi ~k. k i ~ A Sample Receipt Criteria Comments/Quamliners (Required otr Non-Conforming Items)Shipping containers received intact Circle Applicabl:

seals broken damaged cominer leaking container other (describe) and sealed? AM7_Samples requiring cold Ci-cle coolant # ice bags blue ice dry ice Qn) other demrf)2 preservation within (4 +1- 2 C)?Record preservation method. -C_Chain of custody documents CO Us ca( 6 V CA-included with shipment?

, Sample containers intact and ;in;kA~picabtW; sdizu br= damged container leaking container (odxw (describe) sealed? CR-Ctig i11qm q4% ,_Samples requiring chemical ID's. comainc- affected and obsmd pH: .preservation at proper pH?VOA vials free of headspace Samle ID's and contaiaers affected: 6 (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

.. ....9 Samples received within holding ld'3 and t afece: time?SSample ID's on COC match ID's Sample ID's and cowaies affected: on bottles?10Date & time on COC match date Sample ID's affected:& time on bottles?Number of containers received ,Upl ID's affected: match number indicated on COC?COC form is properly signed in t CbC,3 Cit. YWrVIt svkt d einuished/received sections?

__________________________

Air Bill ,Tracking

  1. 's, & %et osrt )tmuOd,-t l*ke-i Additional Comments* '11 RSO RAD Receipt I Suspected Hazard Information e -If > x2 am backgroun is observed on samples identified a3 *non-Za ~ regulated/non-radioaczive.

contact the Radiation Safety group for further_ __ investigation.

  • Radiological Classification?

Maximum Counts Observed*:

C t ., B lPC Regulaie?

Comments:[Shipped as DO)I Hazardous c f Material?

If yes, contact Waste / Hazard Class Shipped: NManager or ESH Manager. UN: PM (or PMA) review of Hazard classification:

Iniials Date: , o rageL _ of 1U5 V SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM ,4A~ 167- 932 J&Z85_____ _____ ____ C9WC)t) uw?)3O A 00K'o 00 S Leq 7, q\ -(0033) ) .(a 105 A% doý'W- 0,0 53? VP f(A)5 c~cIýlev h a.d m ~ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _b u s f td 3C LM__ _ _ _ ___.-_ _ _ _ __ _ _ _Page 30 of 105 Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major (bQ CD A ConneticutChain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00367 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 3-7 / f_ __Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 294070 o 843 556 8171. Atta. Cheryl Jones Ln I, Priority:

[0 30 D.[] 14 D. El 7 D. Container Sample Size-Mcdia Type &Type Sample Designation Date Time code Code Code Comment, Preservation Lab Sample ID 9106-0008-001F 5/05/06 11:13 SE C BP X XX Transferred from COC # 2006-00324 9106-0008-003F 5/5/06 13:35 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-004F 5/5/06 13:51 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-OOSF 5/5/06 14:17 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-006F 5/5/06 14:36 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-006FS 5/5/06 14:36 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-007F 5/5/06 15:03 SE C xBP X Transferred from COC # 2006-00325 9106-0008-002F 5/5/06 13:10 SE C BP X X X Transferred from COC # 2006-00325 NOTES: PO #: 002332 MSR#: 06- -/3 SSWP#NA SLTP QA El Radwaste QA E] Non QA I I. /1) elinqu Date/Time

2) e ivI d = Ie Time 3) Winquished By Date/Time
4) Reaeive y v late/Time Samples Shipped Via:[ Fed Ex El UPS Dl Hand El Other Bill of Lading #Internal Container Temp.: _ Deg. C Custody Sealed?YO NO Custody Seal Intact?YO No Health Physics Procedure GPP-GGGR-R5 104-003-Attachmnent B-CY-001I Major Health Physics Procedure GPP-GGGR-R5 1 04-003-Attachment B-CY-00 1 Major~Chain of Custody Form~No. 2006-00366 CD Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556

.,._ __ I ... .0 --Project Name: Haddamn Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 , 843 556 817 1. Atta. Cheryl Jones z Priority:

Z 30 D. [] 14 D.'[-]7 D, Container Sample Size--Media Type &Type "" Sample Designation Date Time Code Code Code Comment Preservation Lab Sample ID p 9106-0008-008F 5/08/06 08:01 SE C BP X x x Transferred from COC # 2006-00327 010 9106-0008-009F 5/08/06 08:32 SE C BP X x x Transferred from COC # 2006-00327 oil 9106-0008-01OF 5/08/06 09:09 SE C BP X x x Transferred from COC # 2006-00327 01 9106-0008-01OFS 5/08/06 09:09 SE C BP X X X Transferred from COC # 2006-00327 1 9106-0008-01IF 5/08/06 09:30 SE C BP x X X Tranferred from COC # 2006-00327 I 9106-0008-012F 5/08/06 09:53 SE C BP X Transferred from COC N 2006-00327 514 9106-0008-013F 5/08/06 10:16 SE C BP X X X Transferred from COC #2006-00327 9106-0008-014F 5/08/06 10:47 SE C BP X X X Transferred from COC # 2006-00327 NOTES: PO #: 002332 MSR #: 06- 67q3 SSWP# NA SLTP QA Dl Radwaste QA 0l Non QA Samples Shipped Via: Z Fed Ex F1 UPS Dl Hand El Other Bill of Lading #Internal Container Temp.: "Z J Deg. C Custody Sealed?YO N)T Custody Seal Intact?1) Relinquished By Date/Time

2) Received By I' 0Q 1 A4,Itelh)Date/Time~t,._Q , 3) Rlinuishd B Dat/Tie 4 Recive By atetiI 3) Relinquished By Date/Time
14) Received By Date/Time Y97 NO
  • Connecticut Yankee Ijc374 ..Statement of Work for Analytical Lab Services -CY-ISC-SOW-001 Figure 1. Sample Check-in List.Date/rime Received:

_abYLIoto SDG#: Work Order Number:____

Shipping Cdhtainer ID:0_ ¢'" , l Chain of Custody # 0 0.C 3--0 3 4 f 1. Custody Seals on'shipping container intact?.. -Yes ['rT o [I 2. Custody Seals dated and signed? Yes [ j No [-3. Chain-of-Custody record present? Yes [-"o [1..4. Cooler temperature

5. Vermiculite/packing materials is: -Wet [ .Dry -, ] /A 6, "Number of samples in shipping container: " " 7. Sample holding times exceeded?

Yes [ ] No 8. Samples have:_____hazard labels-.custody seals /_appropriate sample labels 9. Samples are:._ in good condition

_ leaking-broken -have air bubbles 10. Were any antomalies identified in sample receipt? Yes ' ] No-11.....Description ofanomalies. (include sample numbers): Telephoned to:__ 0n _ "___ ___" On By.*. .' -.-Page 33 of 105

~~SAI4LE RECEIPT & REVIEW FORM CCW)C9 4,, PM meq oMB S DG/ARCOC/War Order: -b V..( s R ee qf 4e .t)i ( d o m -me -e; a re r e so, , e- p r i o r t o ds g m l u ) : R e lv y .- --I Sample Receipt Criteria ~CommenbtQuailfles (Required for Non-Confo=nlf Item)Shipping containers received intact / A .... d cc=...- le-k-- .,--au. (,ac._ ,)and sealed? Samples requiring cold cle CooCa 0 ice b.ue ice dry keo d---2 preservation within (4 +/- 2 Q?Record preservation method. " 3Chain of custody documents inchlded with shipment?

_ _,_,_, Sample containers intact and iaro ken daim sis Cofit d mag ed ina contaer W d"-- (dcib)4 sealed? _____________________

Samples requiring chemical / WD's. cImiueM affemed and observed pH: preservation at proper PH? ,_, VOA vials free of headspace

/pl: D's d m m'ct.(defined as < 6mm bubble)?Are Encore containers present?7 (If yes. immediately deliver to VOA laboratory)

Samples received within holding /d's and mafted: time?SSampli D's on COC match ID's ID's sed cmieflets affecte: on bottles?Dat & time on COC match date muvi I'S afcd:& time on bottles?Number of containers received /f'aew: match number indicated on COC?COC form is properly signed in relinquished/received sections?Air Bill ,Tracking

  1. 's, &.Addition

.11111 11=3 f5 4 r Suspeced Hazard information d1 SO IRSO RAD Recipt I-~I f .~j > x2 ame backgrond is observed on samiples identified as !11W-" j regulated"/non-radioactive", contact the Radiation Safety group for fur ad- linvestigadon.

71 ~.---~ 4 I lql j% -a n.m ass on, V i ConsOsre*:

Che1 0*fL7 -g 0 B lIhanaeras or1 _HMazarders CiMaterial?:

if yes, contact Waste I -IManager or ESH Manager..I lazard Class Shipped: JHI: PM (or PHfA) review of Hazard classification:

Initials RA!Z ./40/- Date: I-Page 34 of 105 j SAMPLE RECEIPT & REVIEW FORM 107'el1011it PM uase Gal7 CClient: Yanke& SDG/ARCOC/Work Order: I37 Tl '/.Date Received: ,PM(A) Review (ensure so,-.ronr,,g it.- -- r',lve prior tosgin" fReceived By: C I _. A' r"h', _ __ _ _ _ __-Sample Receipt Criteria Z Comments/Qualifirs (Required for Non-Conforming Items)Shipping containers received intact Cirde Applicable:

seals broken damaged container leaking container other (describe) 1 and sealed?Samples requiring cold Circle COolat # ice bags blue ice dry ice i5 odwer describe)2 preservation within (4 +/- 2 C)?Record preservation method.3 Chain of custody documents-included with shipment?

1 4 Sample containers intact and- Circle Applicable:

seals broken damaged container leaking container odter (describe) sealed?5 Samples requiring chemical Sample ID's. containers affected and observed pH:-preservation at proper pH? _" 6 VOA vials free of headspace Satmle- ID's and containers affected: ( (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to /VOA laboratory) 8iSamples received within holding tsd and tseat affected.time? _____________________________

9 Sample ID's on COG match ID's S,,arple ID's and comntners affected: on bottles? --.-10 Date & time on COC match date Sample ID's affected:& time on bottles?Number of containers received Sample ID's affected: 1 match number indicated on COC? I COC form is properly signed in o 4-l,-., aflqL. I 2 relinquished/received sections?14 Air Bill ,Tracking F's, & "1 t 't.-f ILace Additional Comnents Suspected Hazard Information v IsOh I GSJ RSO RAD Receipt #*if > x2 area background is observed on samples identified as 'non-regulated/non-radioactive', contact the Radiation Safety group for further investigation.

-~ -........-.

'-A I Radiological Classitacation9 vI ounts Observed*:'

40 f.P-t-B PCB Regulated?

Shipped as DOI Hazardous Material?

If yes, contact Waste L i Manager or ESH Manager.I Hazard Class Shipped: UN#: 'j Initials , Date: I PM (or PMA) review of Hazard classification:

Page35 of 105 I (oB-7q I V, Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O01 Figure 1. Sample Check-in List DaterTime Received:

57/ IkeI Tt@ O' "3 SDG#: Work Order Number: Shipping Cdntainer ID: 1qe 2 104 i1113 Chain of Custody# .S?3ip " La-., 1. Custody Seals ori shipping container intact?..

  • Yes j o [I 2. Custody Seals dated and signed? Yes Lý1o [ ]-3. Chaia-of-Custody record present? Yes L-9o [I 4. Cooler temperature
  • 2/ .5. Vermiculite/packing materials is: Wet ry 1`1]6. -- Number of samples in shipping container:

hk "tj h-7. Sample holding times exceeded?

Yes- [ No 8. Samples have:-" tape hazard labels custody seals appropriate sample labels 9. Samples are--,.-in good condition leaking broken ____have air bubbles 10. Were any anomalies identified in sample receipt?11. )Description of anomalies (include sample numbers):.

Yes [ I No A* A ./Sample. Custodian/Laboratory:

el cz;Telephoned to: On Datez By Page 36 ofl105 1~1 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major/ & 4 5401 -/.Chain of Custody Form Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 No. 2006-00380 Project Name: Haddam Neck Decommissioning Analyses Requested LabkUse. Only, t Contact Name & Phone: C6mments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road, Charleston SC. 29407 0 < , 843 556 8171. Attn. Cheryl Jones C /)Priority:

Z 30 D. D] 14 D. E] 7 D. Container Sample Size-Media Type &Type .Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 5/15/06 13:28 SE C BP x X Transferred from COC 2006-00352

,1 9106-0009-016FS 5/15/06 13:28 SE C BP x x Transferred from COC 2006-00352 9106-0009-017F 5/15/06 14:03 SE C BP X X Transferred from COC 2006-00352 9106-0009-011F 5/15/06 14:03 SE C BP X Transferred from COC 2006-00351 9106-0009-013F 5/15/06 08:35 SE C BP x X Transferred from COC 2006-00351 9106-0009-013FS 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 D17 9106-0009-014F 5/15/06 08:59 SE C BP X Transferred from COC 2006-00351 6i1 9106-0009-015F 5/15/06 09:36 SE C BP X X Transferred from COC 2006-00351 9106000-01F 515/6 0936 E C BP X TrnsferedromOC206-035 NOTES: PO #: 002332 MSR #: 06-Og1f SSWP#NA E LTP QA 0 Radwaste QA El Non QA Samples Shipped Via: 2 Fed Ex LI UPS F1 Hand El Other 1) Relinquis;d By Date/Time

2) Rec d y Date/Time 3) Relinquished By Date/Time
4) Re eivek By Date/Time Internal Container Temp.: ___ Deg. C Custody Sealed?YO NO]Custody Seal Intact?YFt N !Bill of Lading #Ft Health Physics Procedure/ 1'zJ W-1 GPP-GGGR-R5104-003 -Attachment B-CY-001 Major CD 0 0~Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00381 362 Injun Hollow Road, East Hampton, CT 06424~860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only DContact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories n 2040 Savage Road. Charleston SC. 29407 0?843 556 8171. Attn. Cheryl Jones W z Priority:

Z 30 D.[] 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample IDýt 9106-0009-OOIF 5/11/06 13:22 SE C BP X X Transferred from COC 2006-00347

[ 9106-0009-002F 5/11/06 13:46 SE C BP X X Transferred from COC 2006-00347 9106-0009-003F 5/11/06 14:06 SE C BP x x Transferred from COC 2006-00347 ( 9106-0009-004F 5/11/06 14:30 SE C BP X X Transferred from COC 2006-00347 IA 9106-0009-005F 5/11/06 14:55 SE C BP x X Transferred from COC 2006-00347" 9106-0009-007F 5/12/06 07:44 SE C Bp X X Transferred from COC 2006-003489106-0009-008F 5/12/06 08:16 SE C BP x x Transferred from COC 2006-00348 ( 9106-0009-009F 5/12/06 08:35 SE C BP x x Transferred from COC 2006-00348

'! 9106-0009-OIOF 5/12/06 09:07 SE C BP X X Transferred from COC 2006-00348 01 01 0 01 04 01 61 NOTES: PO #: 002332 MSR #- 06-SSWP# NA [9 LTP QA 77 Radwaste QA E] Non QA 1) Relinquished By Date/Time

2) Rece edy Date/Time Sr Azq6111: 46 0 L 3) Relinquished By Date/Time
4) Receivedby Date/Time Samples Shipped Via:[ Fed Ex Ti ps El Hand El Other Bill of Lading #/q tl /y/ I-VIT Internal Container Temp.: _ Deg. C Custody Sealed?YE] NO Custody Seal Intact?YO ND i~~~45~IZ.ILI)Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-sOw-o00 Figure 1. Sample Check-in List Date/Time Received:-

1 -U6- 0 SDG#:_ __ _ S __.___ _____ _Work Order Number: Shipping Cdntainer ID: 1.', lift 1. Custody Seals oxi shipping container intact?.2. Custody Seals dated and signed?3. Chain-of-Custody record present?4. Cooler temperature 0 , 5. Vermiculite/packing materials is: 61 Number of samples in shipping container:

7. Sample holding times exceeded?~. o'~e~<Chain of Custody #Yes -- No [ ]Yesj ].No.o Yes No t Wet [ Dry*Yes [D No [ 1.8. Samples have:)tape _____hazard labels&- custody seals -appropriate sample labels 9. Samples are'-A-in good condition -leaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes[ ] No 11. *..Description ofanomalies (include sample numbers): Sample Custodia/UIbboratory:

Date: _,-- t -L:c2 Telephoned to: On By II, Page 39 of 105 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major 1 Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00349 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 c Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 , C.0 CI " 843 556 8171. Attn. Cheryl Jones U) r z Priority:

Z 30 D. Fl 14 D. [17 D. Container

/Sample size- Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID p 9106-0010-OO1F 5/04/06 10:49 SE C BP X X Transferred from COC 2006"00321 0i0 9106-0010-002F 5/04/06 11:12 SE C BP X x Transferred from COC 2006-00321 oit 9106-0010-004F 5/04/06 12:48 SE C BP x X Transferred from COC 2006-00321 9106-0010-006F 5/04/06 13:34 SE C BP X X Transferred from COC 2006-00321 9106-0010-007F 5/04/06 13:21 SE C BP X X Transferred from COC 2006-00321 Iat 9106-0010-009F 5/04/06 14:01 SE C BP X X Transferred from COC 2006-00321 o9 9106-0010-OIOF 5/04/06 14:21 SE C BP X X Transferred from COC 2006-00321 01a 9106-0010-012F 5/04/06 14:44 SE C BP X X Transferred from COC 2006-00321 9E--106-0010-013F 5/04/06 15:06 SE C BP x Transferred from COC 2006-00321 ,nt,,a Cntane NOTES: PO #: 002332 MSR#: 06- 0707 SSWP#NA Z LTP QA[I Radwaste QA Dl Non QA 1) RelinquishedBy DateT' e 2) Received By Date/Time 3) Relinquished By Dateftime

4) Recelived By Date/Time Samples Shipped Via: Z Fed Ex E ups El Hand El Other Bill of Lading #~3 ý4o- 3)U-9ýInternal Container Temp.: /17Deg. C CustodySealed?

Y9" NO3 Custody Seal Intact?Y 9-"N D Connecticut Yankee Statement of Work for Analytical Lab Services CY-lsc-Sow.-0l1 Figure 1. Sample Check-in List.Al1C ..I C DateiTime Received:

67 ./. 1 0 SDG#: 7 -.Work Order Number:__ Shipping Ccfntainer ID: -7'0 31gi? 85s yl 1. Custody Seals ori shipping container intac 2. Custody Seals dated and signed?3. Chain-of-Custody record present?.4. Cooler temperature (7 'C 5. Vermiculite/packing materials is: 6. Number of samples in shipping container:

7. Sample holding times exceeded?b&A -07/ -7 Chain of Custody # ' " 39 t? Yes .INo [ ]Yes [' No [I1.Yes [4 No Wet Dry Li Yes [ ] No i,.8. Samples have:'._tape -hazard labels......custody seals appropriate sample labels 9. Samples arei AAIL._ in good condition

..leaking-broken --have air bubbles 10.I ._Were any anomalies identified in sample receipt?-.Description of anomalies (include sample numbers): Yes [ No Sample Custodian/taboratory:

Date: ,- 0 o Telephoned to: "-n0 By O-Page 41 of 105-1 -11, M q'-ENG/A 4 V SAMPLE RECEIPT & REVIEW FORM 0 IhM use only Client: (~g/SDG/ARCOCIWork-Order: Date Received:

S- [ "7 PM(A) Review g itens are resolved prior to signing): Received By: A4- 4 I Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conrorning Items)Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (describe) and sealed? I Samples requiring cold Circlc Coolant # ice bags blue ice dry ice 4 other describe)2 preservation within (4 +/- 2 C)?Record preservation method.Chain of custody documents included with shipment?4 Sample containers intact and Circle Applicable:

seals broken damaged container leaking container other (desc'ibc) sealed?~ Sampies requiring chemical Sample ID's. containers affected and observed pH: preservation at proper pH?6 VOA vials free of headspace Sample ID's and containers affected: 6 (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory) 8 Samples received within holding Id's and tests affected: time?9 Sample ID's on COC match ID's Sample ID's and containers affected: on bottlesS Date & time on COC match date Sample I's affected: 10& time on bottles? V Number of containers received Sample ID's affected: match number indicated on COC?12 COC form is properly signed in 2 relinquished/received sections?Air Bill ,Tracking

  1. 's, &Additional Comments' v* -RSO RAD Receipt #_5 -if > x2 area background is observed on samples identified as "non-Suspected Hazard Information 0 regulated/non-radioactive", contact the Radiation Safety group for further_X 9 investigation.

A IRadiological Classification?

1 -Maximum Counts Observed*:

B IPCB Regulated?

V omns Shipped as D iT Hazardous I C Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. UN#: PM (or PMA) review of Hazard classification:

Initials Date: /,,.1 /Page 42 of 105 List of current GEL Certifications as of 15 August 2006 7171.. State Alaska Arizona-Arkansas CLIA K California Colorado Connecticut Dept. of Navy EPA Florida/NELAP Georgia Idaho Illinois Indiana Kansas Kentucky Maryland Massachusetts Michigan Nevada New Jersey New York-North Carolina North Carolina Drinking W North Dakota Oklahoma Pennsylvania South Carolina Tennessee Texas U.S. Dept. of Agriculture US Army Corps of Engineer Utah Vermont Virginia Washington Certification UST-062 AZ0668 88-0651 42D0904046 0115 ICA GenEngLabs PH-0169 NFESC 413 WG-15J E87156 E87156 (FL/NELAP)

N/A 200029 C-SC-0 I E-10332 90129 270 M-S COI12 9903 SC002 11501 233 45709 R-158 9904 68-485 10 120001/10585001/10120002

.. .02934 .TX213-2006A S-52597 N/A 8037697376 GEL N/A 00151.... .... C 223 .. .. ....i Page 43 of 105 RADIOLOGICAL ANALYSIS Page 44 of 105 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 168404 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555696 554650 554649 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404011 168404012 168404013 168404014 168404015 1201153129 1201153130 1201153131 1201153132 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-01OF 9106-0005-014F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-OO1F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 11 REV# 14.Page 45 of 105 Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 168404003 (9106-0003-004F) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Page 46 of 105 Product: Alphaspec Am241, Cm, Solid ALL FSS DOE EML HASL-300, Am-05-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 557837 554650 554649 Sample ID 168404009 168404010 1201158316 1201158317 1201158318 1201158319 Client ID 9106-0006-005F 9106-0008-006F Method Blank (MB)168404009(9106-0006-005F)

Sample Duplicate (DUP)168404009(9106-0006-005F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168404009 (9106-0006-005F).

QC Information Page 47 of 105 All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555697 554650 554649 Page 48 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201153133 1201153134 1201153135 1201153136 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-OO1F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011 (9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Page 49 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu- I1-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555698 554650 554649 Page 50 of 105 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-011 F 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01 OF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F 1201153137 Method Blank (MB)1201153138 168340011(9304-01-005C)

Sample Duplicate (DUP).1201153139 168340011(9304-01-005C)

Matrix Spike (MS)1201153140 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Page 51 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 556350 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 52 of 105 Sample ID 168404003 168404004 168404012 168404013 168404014 168404015 1201154644 1201154645 1201154646 1201154647 Client ID 9106-0003-004F 9106-0003-015F 9106-0009-002F 9106-0009-017F 9106-0010-OO1F 9106-0010-012F Method Blank (MB)168404003(9106-0003-004F)

Sample Duplicate (DUP)168404003(9106-0003-004F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Page 53 of 105 Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Samples 1201154644 (MB), 1201154645 (9106-0003-004F), 1201154646 (9106-0003-004F), 1201154647 (LCS), 168404003 (9106-0003-004F), 168404004 (9106-0003-015F), 168404012 (9106-0009-002F), 168404013 (9106-0009-017F), 168404014 (9106-0010-001F) and 168404015 (9106-0010-012F) were dried and reweighed due to low matrix spike/laboratory control sample recovery.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 554580 Page 54 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201150561 1201150562 1201150563 1201150564 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-01OF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168340012(9304-02-003C)

Sample Duplicate (DUP)168340012(9304-02-003C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.Page 55 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS DOE RESL Fe-1, Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555722 554650 554649 Page 56 of 105 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01 OF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F 1201153222 Method Blank (MB)1201153223 168340012(9304-02-003C)

Sample Duplicate (DUP)1201153224 168340012(9304-02-003C)

Matrix Spike (MS)1201153225 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.Page 57 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555723 554650 554649 Page 58 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 1201153226 1201153227 1201153228 1201153229 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-01OF 9106-0005-014F 9106-0006-005F Method Blank (MB)168340012(9304-02-003C)

Sample Duplicate (DUP)168340012(9304-02-003C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Page 59 of 105 Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Analytical Method: Analytical Batch Number: Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201150569 1201150570 1201150571 1201150572 LSC, Tritium Dist, Solid-HTD2,ALL FSS EPA 906.0 Modified 554582 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-OO1F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)Page 60 of 105 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 168404010 (9106-0008-006F) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Page 61 of 105 Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: Analytical Batch Number: Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201150573 1201150574 1201150575 1201150576 EPA EERF C-01 Modified 554583 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168404003(9106-0003-004F)

Sample Duplicate (DUP)168404003(9106-0003-004F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Page 62 of 105 Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.Page 63 of 105 The following data validator verified the information presented in this case narrative:

Reviewer/Date:

W &&§e-'- ý'q.Page 64 of 105 SAMPLE DATA

SUMMARY

Page 65 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: 168404 GEL Work Order: 168404 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by Page 66 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0002-007F 168404001 SE 18-MAY-06 02-JUN-06 Client 20.9%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Rad Alpha Spec Analysis Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0 Curium-242 U Curium-243/244 U -0.C Alphaspec Pu, Solid-ALL FSS Plutonium-238 U Plutonium-239/240 U 0.Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAllFSS Carbon-14 U 0.Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U+/-0.102+/-0.0995+/-0.0717 0.00 0.00 0.0405+/-0.102+/-0.0995+/-0.0717 0.0956 0.138 0.177 0.444 0.323 pCi/g pCi/g pCi/g pCi/g pCi/g 0.199 +/-0.228.0341 +/-0.129 0.181 +/-0.229 0.120 +/-0.129 10.0 +/-6.64 5.08 +/-6.72 4.17 +/-6.67 5.28 +/-6.67 0813 +/-0.0797 0.0634 +/-0.0797 9.90 +/-48.1 32.0 +/-48.1 7.02 +/-6.39 5.18 +/-6.40).139 +/-0.213 0.173 +/-0.213 10.7 pCi/g 11.4 pCi/g BXLI 08/11/06 1336 555696 1 BXL1 08/11/06 1633 555697 2 BXLI 08/16/06 1220 555698 3 DFAI 08/09/06 1128 554582 4 ATH2 08/09/06 0324 554583 5 MXPI 08/12/06 1633 555722 6 MXPI 08/11/06 0738 555723 7 EGD1 08/11/06 2027 554580 8 0.132 65.9 10.6 0.360 pCi/g pCi/g pCi/g pCi/g The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 Analyst Date Time Prep Batch LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu- I l-RC Modified 3 DOE EML HASL-300, Pu- I1-RC Modified 4 EPA 906.0 Modified Page 67 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0002-007F 168404001 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 6 7 8 EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-1, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL F5 Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%80 100 98 75 76 74 Acceptable Limits (15%-125%)

(15/%-125%)

(25%-/125%)

(15%-125%)

(25%-/125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 68 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0002-011F 168404002 SE 19-MAY-06 02-JUN-06 Client 17.4%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americitum-241 U 0.120 Curium-242 U -0.0146 Curium-243/244 U -0.0103 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0121 Plutonium-239/240 U 0.0254 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.72 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -0.521 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.023 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 3.93 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.52 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.173 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.154+/-0.122+/-0.0861+/-0.125+/-0.0675+/-7.02+/-7.03+/-0.0828+/-47.7+/-5.81+/-0.203 0.0683 0.0692 0.0487 0.127 0.0381 5.56 5.94 0.0685 31.9 4.68 0.164+1-0.155+/-0.123+/-0.0862+/-0.125+/-0.0675+/-7.05+/-7.03+/-0.0828+/-47.7+/-5.81+/-0.203 0.251 0.303 0.213 0.344 0.167 11.7 12.8 0.143 65.7 9.60 0.341 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1336 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1237 555698 3 DFA I ATH2 MXPI MXPI EGD1 08/09/06 1143 554582 08/09/06 0426 554583 08/12/06 1649 555722 08/11/06 0825 555723 08/11/06 2043 554580 4 5 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 3 4 5 DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-11-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified Page 69 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-01IF Proiect: YANK01204 Sample ID: 168404002 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-1, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 76 (15%- 125%)Plutonium-242 Alphaspec Pu, Solid-ALL FSS 100 (15/-/125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 88 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%- 125%)Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%°-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 70 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0003-004F 168404003 SE 25-APR-06 05-MAY-06 Client 23.5%Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.027 Curium-242 U 0.112 Curium-243/244 U 0.0217 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.061 Plutonium-239/240 U 0.0551 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.00343 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.603 Liquid Scint C14, SolidAlFSS Carbon-14 U 0.0937 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 7.68 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.74 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0643 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.117+/-0.315+/-0.206+/-0.189+/-0.103+/-5.73 0.153 0.245 0.205 0.176 0.0584 4.40+/-0.117+/-0.315+/-0.206+/-0.189+/-0.103+/-5.78+/-0.0203 0.0172 +/-0.0203 0.488 0.781 0.594 0.449 0.215 9.25 0.036 14.8 0.134 70.4 13.6 0.351 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/13/06 0819 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1253 555698 3 BXFI 08/14/06 0834 556350 4+/-8.25+/-0.0813+/-51.2+/-7.12+/-0.198 6.87 0.0642 34.2 6.58 0.169+/-8.25+/-0.0813+/-51.2+/-7.13+/-0.198 DFA I ATH2 MXP1 MXPI EGD 1 08/09/06 1159 554582 08/09/06 0529 554583 08/12/06 1706 555722 08/11/06 0912 555723 08/11/06 2059 554580 5 6 7 8 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method 1 2 Description DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified Page 71 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-004F 168404003 Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%42 92 113 59 71 83 76 Acceptable Limits (15%-125%/6)

(15%-125%)

(25%-125%)

(25%-/125%)

(15%-125%)

(25%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 72 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-004F 168404003 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.Page 73 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0003-015F 168404004 SE 25-APR-06 05-MAY-06 Client 22.5%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0456 Curium-242 U 0.113 Curium-243/244 U 0.180 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0196 Plutonium-239/240 U 0.0326 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.63 Rod Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00477 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 1.03 Liquid Scint C14, SolidAllFSS Carbon-14 0.156 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -9.99 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.939 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.237 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.155+/-0.181+/-0.239+/-0.121+/-0.0639+/-6.19 0.139 0.0733 0.181 0.118 0.00 4.86+/-0.155+/-0.182+/-0.240+/-0.121+/-0.064+/-6.22+/-0.0216 0.0179 +/-0.0216 0.387 0.321 0.472 0.324 0.0884 10.2 0.0375 12.6 0.146 59.2 21.6 0.353 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXL1 08/16/06 1309 555698 3 BXF1 08/14/06 0834 556350 4+/-7.06+/-0.0912+/-42.7+/-10.1+/-0.213 5.85 0.0699 28.7 10.3 0.170+/-7.06+/-0.0913+/-42.7+/-10.1+/-0.213 DFAI ATH2 MXPI MXPI EGDI 08/09/06 1215 08/09/06 0632 08/12/06 1722 08/11/06 1001 08/11/06 2115 554582 554583 555722 555723 554580 5 6 7 8 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified Page 74 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of AnalTsis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-015F 168404004 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter 3 4 5 6 7 8 9 Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd DOE EML HASL-300, Pu-1Il-RC Modified EPA 905.0 Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL F5 GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%78 94 101 58 75 62 75 Acceptable Limits (15%o-125%)

(15%-125%)

(25%-/125%)

(25%-I125%)

(15%-125%)

(25%-125%)

(15%-I125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 75 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-015F 168404004 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.Page 76 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0004-005F 168404005 SE 03-MAY-06 12-MAY-06 Client 15.4%Proiect: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Rc Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0 Curium-242 U -0.i Curium-243/244 U -0.AIphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.(Plutonium-239/240 U -0.(Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0 Liquid Scint C14, SolidAllFSS Carbon-14 0 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.(esuit Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd'.036 0169 0129 0217 0708 9.52'.854.347 1.57 6.39 0198+/-0.123+/-0.033+/-0.227+/-0.163+/-0.0791+/-6.00+/-5.88+/-0.097+/-46.0+/-7.62+/-0.187 0.157 0.080 0.247 0.181 0.128 4.57 4.87 0.0674 30.7 7.40 0.156+/-0.123+/-0.0331+/-0.227+/-0.163+/-0.0795+/-6.07+/-5.88+/-0.0972+/-46.0+/-7.62+/-0.187 0.437 0.350 0.619 0.444 0.337 9.61 10.5 0.141 63.2 15.5 0.324 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1326 555698 3 DFA I ATH2 MXPI MXPI EGD1 08/09/06 1231 554582 08/09/06 0734 554583 08/12/06 1738 555722 08/11/06 1017 555723 08/11/06 2131 554580 4 5 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method 2 3 4 5 Description DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I l-RC Modified DOE EML HASL-300, Pu-I 1-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified Page 77 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: 9106-0004-005F 168404005 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%65 95 105 78 80 80 Acceptable Limits (15 %-125%)(15%- 125%)(25%-/125%)

(15%-125%o)

(25%- 125%)(15°-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 78 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0004-015F 168404006 SE 03-MAY-06 12-MAY-06 Client 26.5%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0 Curium-242 U -0 Curium-243/244 U -0 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0 Plutonium-239/240 U -'Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAllFSS Carbon-14 U 0.Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.+/-0.203+/-0.0301+/-0.251 0.178 0.0729 0.300+/-0.203+/-0.0302+/-0.251 0.469 0.319 0.713 0.521 0.483 pCi/g pCi/g pCi/g pCi/g pCi/g.0466 +/-0.213 0.142 +/-0.108 0.210 +/-0.213 0.191 +/-0.109 6.64 +/-6.53 5.16 +/-6.57-2.9 +/-7.59 6.60 +/-7.59 0352 +/-0.0868 0.0713 +/-0.0868 1.88 +/-46.8 31.3 +/-46.8 3.88 +/-7.46 7.40 +/-7.46 0894 +/-0.198 0.163 +/-0.198 10.8 pCi/g 14.2 pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1342 555698 3 DFAI 08/09/06 1247 554582 4 ATH2 08/09/06 0837 554583 5 MXPI 08/12/06 1754 555722 6 MXPI 08/11/06 1033 555723 7 EGD1 08/11/06 2147 554580 8 0.149 64.4 15.5 0.338 pCi/g pCi/g pCi/g pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-1 I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified Page 79 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 lnjun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0004-015F 168404006 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter 6 7 8 Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd DOE RESL Fe-I, Modified DOE RESL Ni-1, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýLiquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%72 72 94 73 80 78 Acceptable Limits (15%-125%)

(15%-/125%)

(25%-I 25%)( 15°%/- 125%)(25%-/125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 80 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0005-01OF 168404007 SE 02-MAY-06 09-MAY-06 Client 56.2%Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Re Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0 Curium-242 U -0.i Curium-243/244 U -0.(Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.(Plutonium-239/240 U 0.(Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAILFSS Carbon-14 U 0.1 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -esult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd).128 0115 0333 0548 0195 10.4 0.00 0636 36.1 7.26 0.05+/-0.0939+/-0.128+/-0.122+/-0.169+/-0.121+/-6.89+/-6.86+/-0.0801+/-44.1+/-10.2+/-0.199 0.142 0.147 0.149 0.158 0.117 5.27 5.76 0.0644 28.7 10.0 0.169+/-0.0942+/-0.128+/-0.122+/-0.170+/-0.121+/-6.97+/-6.86+/-0.0801+/-44.1+/-10.2+/-0.199 0.385 0.450 0.401 0.403 0.322 11.1 12.4 0.135 59.0 20.9 0.351 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1358 555698 3 DFA1 ATH2 MXPI MXPl EGD1 08/09/06 1303 554582 08/09/06 1017 554583 08/12/06 1811 555722 08/11/06 1049 555723 08/11/06 2203 554580 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Method 1 2 3 4 5 Analytical Methods were performed Description DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-l 1-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified Page 81 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-010F Project: YANKO 1204 Sample ID: 168404007 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 85 (15'-/125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 92 (25%-/125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 (15/-/125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 64 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 77 (15%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 82 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00591 Curium-242 U -0.04 Curium-243/244 U 0.0634 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0694 Plutonium-239/240 U -0.0287 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.68 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 6.02 Liquid Scint C04, SolidAllFSS Carbon-14 U 0.0892 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 19.8 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.41 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.134 9106-0005-014F 168404008 SE 02-MAY-06 09-MAY-06 Client 32.3%Project: Client ID: Vol. Recv.: YANKO 1204 YANKOO I Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.219+/-0.0554+/-0.261 0.231 +/-0.219 0.134 +/-0.0557 0.249 +/-0.261 0.608 0.494 0.646 0.434 0.369 pCi/g pCi/g pCi/g pCi/g pCi/g+/-0.106 0.160 +/-0.106+/-0.098 0.127 +/-0.0981+/-8.01 6.48 +/-8.02+/-6.38 4.90 +/-6.38+/-0.0827 0.0655 +/-0.0827+/-46.3 30.6 +/-46.3+/-7.91 7.77 +/-7.91+/-0.192 0.167 +/-0.192 13.6 pCi/g BXL1 08/11/06 1434 555696 1 BXL1 08/11/06 1633 555697 2 BXL1 08/16/06 1415 555698 3 DFAI 08/09/06 1319 554582 4 ATH2 08/09/06 1424 554583 5 MXPI 08/12/06 1827 555722 6 MXPI 08/11/06 1106 555723 7 EGD1 08/11/06 2218 554580 8 10.6 0.137 62.9 16.2 0.346 pCi/g pCi/g pCi/g pCi/g pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 3 4 5 DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified Page 83 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0005-014F 168404008 Project: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter 6 7 8 Qualifier Result Uncertainty DOE RESL Fe-I, Modified DOE RESL Ni-i, Modified DOE EML HASL-300, Tc-02-RC Modified LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALl Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%50 61 74 76 76 75 Acceptable Limits (15%-125%)

(15%-125%)

(25%-/125%)

(15%-I125%)

(25%-/125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 84 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21,2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-005F 168404009 SE 28-APR-06 12-MAY-06 Client 16.5%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANKOOI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -Curium-242 U -Curium-243/244 U -Alphaspec Pu, Solid-ALL FSS Plutonium-238 U Plutonium-239/240 U 0 Liquid Scint Pu24 1, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis 0.0851 0.0253 0.0479+/-0.136+/-0.0495+/-0.0542 0.106 0.120 0.131+/-0.136+/-0.0496+/-0.0545 0.390 0.525 0.443 0.303 0.221 9.82 0..0'0183 +/-0.113 0.110 +/-0.113 0122 +/-0.0662 0,0694 +/-0.0662 4.43 +/-5.83 4.67 +/-5.85 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -Liquid Scint C14, SolidAllFSS Carbon- 14 0 Liquid Scint Fe55, Solid-ALL FSS lron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0'BXL1 08/16/06 0949 557837 1 BXL1 08/11/06 1633 555697 3 BXLI 08/16/06 1431 555698 4 DFAI 08/09/06 1335 554582 5 ATH2 08/09/06 1719 554583 6 MXPI 08/12/06 1843 555722 7 MXPI 08/11/06 1122 555723 8 EGDI 08/11/06 2234 554580 9-2.02 +/-6.67 5.76 +/-6.67 1.142 +/-0.0798 0.061 +/-0.0799 12.6 +/-47.6 31.7 +/-47.6 7.70 +/-9.56 9.31 +/-9.56 0659 +/-0.185 0.156 +/-0.185 12.4 pCi/g 0.127 65.3 19.5 0.323 pCi/g pCi/g pCi/g pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 3 4 5 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-0I -RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified Page 85 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0006-005F 168404009 Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 9 EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Arnericium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%76 93 105 72 64 81 Acceptable Limits (15%- 125%)(15%-125%)

(25%-/125%)

(15%-125%)

(25%-.125%)

(15%- 125%)Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 86 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analvqiq Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0008-006F 168404010 SE 05-MAY-06 26-MAY-06 Client 34.8%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U C Curium-242 U 0 Curium-243/244 U -0.1 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.i Plutonium-239/240 U 0.01 Liquid Scint Pu241, Solid-ALL FSS Plutonium-24I Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidA/lFSS Carbon-14 U 0 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0'.129 1.103 0161+/-0.195+/-0.202+/-0.0316 0.0758 0.00 0.0766+/-0.196+/-0.203+/-0.0317 0276 +/-0.0711 0.0967 +/-0.0712 0359 +/-0.113 0.118 +/-0.113 14.9 +/-6.37 4.64 +/-6.51 0.00 +/-6.06 5.09 +/-6.06.107 +/-0.0846 0.0664 +/-0.0846 15.1 +/-41.4 27.5 +/-41.4.258 +/-0.225 0.179 +/-0.225 0.332 0.280 0.335 0.275 0.317 9.75 10.7 0.139 56.6 0.373 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 08/16/06 0949 557837 1 BXLI 08/11/06 1633 555697 3 BXL1 08/16/06 1447 555698 4 DFA1 08/10/06 2150 554582 5 ATH2 08/09/06 1822 554583 6 MXPI 08/12/06 1900 555722 7 EGD1 08/11/06 2251 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 6 7 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-11-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-1, Modified Page 87 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0008-006F 168404010 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 8 DOE EML HASL-300.

Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Test Recovery%

Acceptable Limits Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 77 94 103 72 71 (15%-125%)

(15%-125%)

(25/- 125%)(15%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 88 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0008-008F 168404011 SE 08-MAY-06 26-MAY-06 Client 35.7%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.Curium-242 U -0.Curium-243/244 U -0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.Plutonium-2 39/240 U -0.Liquid Scint Pu24 1, Solid-ALL FSS Plutonium-241 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAllFSS Carbon-14 U -0.Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.+/-0.192+/-0.142+/-0.202 0.152 +/-0.193 0.132 +/-0.142 0.240 +/-0.203+/-0.096 0.125 +/-0.096+/-0.114 0.137 +/-0.114 11.5 +/-6.72 5.08 +/-6.80 0.00 +/-5.92 4.97 +/-5.92 0238 +/-0.0745 0.0636 +/-0.0745-10.7 +/-40.9 27.5 +/-40.9 0956 +/-0.211 0.174 +/-0.211 0.426 0.446 0.603 0.328 0.353 10.7 10.7 0.133 56.8 0.361 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1504 555698 3 DFAI 08/09/06 1407 554582 4 ATH2 08/09/06 1924 554583 5 MXPI 08/12/06 1916 555722 6 EGDI 08/11/06 2307 554580 7 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 6 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I 1-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified EPA EERF C-0I Modified DOE RESL Fe-I, Modified Page 89 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0008-008F 168404011 Project: Client ID: Vol. Recv.: YANKO1204 YANK001 Parameter 7 Qualifier Result Uncertainty DOE EML HASL-300, Tc-02-RC Modified LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%65 98 96 76 74 Acceptable Limits (15%-125%)

(15%-1125%)

(25%-125%)

(15%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 90 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com UPrtifirntt nf Anal civ.I.Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.00144 Curium-242 U 0.0192 Curium-243/244 U 0.013 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00587 Plutonium-239/240 U 0.0186 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.6 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.0151 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.12 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.046 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 12.9 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.078 9106-0009-002F 168404012 SE 1 I-MAY-06 08-JUN-06 Client 33%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANKOO 1 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.155+/-0.145+/-0.268 0.166 +/-0.155 0.135 +/-0.145 0.281 +/-0.268+/-0.0493 0.0279 +/-0.0494+/-0.0492 0.0278 +/-0.0493+/-6.90 5.13 +/-7.01+/-0.0146 0.0114 +/-0.0146+/-8.36 6.70 +/-8.36+/-0.0755 0.0613 +/-0.0755+/-40.6 26.8 +/-40.6+/-0.203 0.168 +/-0.203 0.458 0.455 0.687 0.122 0.122 10.8 0.0242 14.5 0.128 55.2 0.348 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1632 555697 2 BXLI 08/16/06 1520 555698 3 BXFI 08/14/06 0834 556350 4 DFA1 08/09/06 1422 554582 5 ATH2 08/09/06 2027 554583 6 MXPI 08/12/06 1932 555722 7 EGD1 08/11/06 2323 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified Page 91 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0009-002F 168404012 Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 6 7 8 EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%61 98 94 69 81 75 Acceptable Limits (15%-125%)

(15%-125%)

(25%-125%)

(25%- 125%)(15%-125%)

(15%- 1 25%)Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 92 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-017F 168404013 SE 15-MAY-06 08-JUN-06 Client 28.4%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0755 Curium-242 U 0.0957 Curium-243/244 U -0.073 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00629 Plutonium-239/240 U 0.0262 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.3 Rad Gas Flow Proportional Counting GFPC, St90, solid-ALL FSS Strontium-90 U 0.0205 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.583 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0271 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -61.9 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0628+/-0.242+/-0.220+/-0.214+/-0.0529+/-0.0513 0.230 +/-0.243 0.171 +/-0.220 0.256 +/-0.214 0.0299 +/-0.0529 0.00 +/-0.0514+/-6.66 4.95 +/-6.77+/-0.0151 0.0116 +/-0.0151+/-7.98 6.65 +/-7.98+/-0.0759 0.0625 +/-0.0759+/-150 102 +/-150+/-0.200 0.165 +/-0.200 0.574 0.509 0.627 0.131 0.0709 10.4 0.0246 14.4 0.131 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 08/11/06 1434 555696 1 BXLI 08/11/06 1632 555697 2 BXLI 08/16/06 1536 555698 3 BXF1 08/14/06 0833 556350 4 DFA1 08/09/06 1438 554582 5 ATH2 08/09/06 2129 554583 6 MXPI 08/12/06 1949 555722 7 EGD1 08/11/06 2338 554580 8 210 pCi/g 0.343 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified Page 93 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Proiect: YANKO 1204 Sample ID: 168404013 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 64 (150-/125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-/125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 96 (25%- 125%)Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 73 (15/-,125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> .Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 94 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0010-00IF 168404014 SE 04-MAY-06 17-MAY-06 Client 27.3%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00677 Curium-242 U 0.0854 Curium-243/244 U 0.0361 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.173 Plutonium-239/240 U -0.0342 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.0 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.0128 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.548 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0555 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -18.1 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.134+/-0.227+/-0.167+/-0.242 0.238 0.00 0.241+/-0.227+/-0.168+/-0.242+/-0.181 0.143 +/-0.182+/-0.0865 0.0951 +/-0.0866+/-6.44 4.78 +/-6.54+/-0.0141 0.0125 +/-0.0141+/-7.50 6.25 +/-7.50+/-0.0809 0.0655 +/-0.0809+/-47.6 32.3 +/-47.6+/-0.205 0.167 +/-0.205 0.628 0.231 0.634 0.331 0.235 10.0 0.0262 13.5 0.137 66.6 0.347 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXL1 08/11/06 2250 555697 2 BXLI 08/16/06 1553 555698 3 BXF1 08/14/06 0833 556350 4 DFAI 08/09/06 1454 554582 5 ATH2 08/09/06 2232 554583 6 MXPI 08/12/06 2005 555722 7 EGD1 08/11/06 2354 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified Page 95 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-OOIF Project: YANK01204 Sample ID: 168404014 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am24I, Cm, Solid ALL 50 (15/-,125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 85 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 99 (25%-125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 74 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 70 (15%-/125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 96 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.110 Curium-242 U -0.0547 Curium-243/244 U -0.126 AIphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00157 Plutonium-239/240 U 0.0867 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.00771 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.896 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0162 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 23.3 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0577 9106-0010-012F 168404015 SE 04-MAY-06 17-MAY-06 Client 28.1%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.184+/-0.141+/-0.184 0.140 0.192 0.245+/-0.184+/-0.141+/-0.185+/-0.126 0.122 +/-0.126+/-0.0869 0.0406 +/-0.0872+/-6.16 4.77 +/-6.21+/-0.0144 0.0124 +/-0.0144+/-6.17 5.11 +/-6.17+/-0.0763 0.0633 +/-0.0763+/-49.3 32.5 +/-49.3+/-0.206 0.171 +/-0.206 0.386 0.544 0.597 0.291 0.128 10.0 0.0263 11.0 0.132 67.0 0.354 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXL1 08/11/06 2250 555697 2 BXLI 08/16/06 1609 555698 3 BXF1 08/14/06 0833 556350 4 DFAI 08/09/06 1510 554582 5 ATH2 08/09/06 2334 554583 6 MXPI 08/12/06 2021 555722 7 EGDI 08/12/06 0010 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu- I -RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 905.0 Modified Page 97 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-012F Project: YANK01204 Sample ID: 168404015 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 81 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 99 (25o %-125%)Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 68 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 74 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 98 of 105 I QUALITY CONTROL DATA Page 99 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client : Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: August 21, 2006 Page I of 6 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

168404 VrnNC Units RPD%.........I alm.jp. eUa Q Rad Alpha Spec Batch 555696 REC% Range Anist Date Time QC120! 153130 Americium-241 Curium-242 Curium-243/244 QC1201153i32 Americium-241 168340011 DUP LCS Curium-242 Curium-243/244 QC1201153129 MB Americium-241 Curium-242 Curium-243/244 QC1201153131 168340011 MS Americium-241 Curium-242 Curium-243/244 U -0.000522 Uncert: +/-0.0385 TPU: +/-0.0385 U 0.00 Uncert: +/-0.0756 TPU: +/-0.0756 U -0.0177 Uncert: +/-0.0764 TPU: +/-0.0765 12.8 Uncert: TPU: Uncert: TPU: 15.5 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 13.3 U -0.000522 Uncert: +/-0.0385 TPU: +/-0.0385 U 0.00 Uncert: +/-0.0756 TPU: +/-0.0756 16.1 U -0.0177 Uncert: +/-0.0764 TPU: +/-0.0765 U 0.0578+/-0.278+/-0.279 U -0.0405+/-0.0562+/-0.0565 U -0.0517+/-0.257+/-0.257 12.8+/- 1.84+/-2.70 U -0.0328+/-0.0454+/-0.0457 14.3+/-1.94+/-2.92 U 0.0471+/-0.157+/-0.157 U -0.0469+/-0.0459+/-0.0464 U -0.00385+/-0.210+/-0.210 pCi/g 200 pCi/g 98 pCi/g pCi/g 204 (0%- 100%) BXLI 08/11/06 14:34 (0%- 100%)(0%- 100%)100 (75%-125%)

pCi/g pCi/g pci/g pCi/g pCi/g pCi/g pCi/g pci/g 92 (75%-125%)

U 12.0+/-1.38+/-2.08 0.0427+/-0.0837+/-0.0839 15.9+/-1.58+/-2.61 91 (75%-125%)

99 (75%-125%)

Batch 555697 QC1201153134 168340011 DUP Plutonium-238 U -0.0155 U 0.0237 pCi/g 956 (0% -100%) BXLI 08/11/0622:51 Page 100 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 2 of 6 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Alpha Spec Batch 555697 Plutonium-239/240 QC1201153136 LCS Plutonium-238 Plutonium-239/240 QC1201153133 MB Plutonium-238 Plutonium-239/240 QC1201153135 168340011 MS Plulonium-238 Plutonium-239/240 Uncert: +/-0.0215 TPU: +/-0.0216 U 0.0414 Uncert: +/-0.0934 TPU: +/-0.0935 Uncert: TPU: 11.8 Uncert: TPU: Uncert: TPU: Uncert: TPU: u -0.0155 Uncert: +/-0.0215 TPU: +/-0.0216 12.3 U 0.0414 Uncert: +/-0.0934 TPU: +/-0.0935 U 7.28 Uncert: +/-6.30 TPU: +/-6.35 U+/-0.0465+/-0.0466-0.0489+/-0.124+/-0.124 pCi/g 2410 pCi/g pCi/g (0%- 100%)(75%-125%)

98 (75%-125%)

U 0.155+/-0.141+/-0.142 11.5+/-0.856+/-1.32 U 0.0552+/-0.186+/-0.186 U -0.0978+/-0.0892+/-0.0899 pCi/g pCi/g pCi/g pCi/g 08/11/06 22:50 U 0.0539+/-0.112+/-0.112 10.3+/-0.796+/-1.19 (75%-125%)

08/11/06 22:51 84 (75%-125%)

Batch 555698 QC1201153138 168340011 DUP Plutonium-241 U 10.1+/-6.39+/-6.46 pCi/g 0 (0% -100%) BXL I QC1201153140 LCS Plutonium-241 QC1201153137 MB Plutonium-241 137 Uncert: TPU: Uncert: TPU: 138 U Uncert: TPU: 145+/-12.5+/-19.9 U 8.57+/-6.93+/-6.98 pCi/g pCi/g pCi/g 106 (75%-125%)

08/16/06 16:41 08/16/06 17:14 08/16/06 16:25 08/16/06 16:58 QC1201153139 168340011 MS Plutonium-241 7.28+/-6.30+/-6.35 Batch 557837 142+/-12.4+/-19.7 0.167+/-0.220+/-0.221 0.241 103 (75%-125%)

QC1201158317 168404009 DUP Americium-241 Curium-242 U -0.0851 Uncert: +/-0.136 TPU: +/-0.136 U -0.0253 U U pCi/g 616 pCi/g 247 (0%- 100%) BXLI 08/16/06 09:49 (0%- 100%)Page 101 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 3 of 6 Parmname NOM Samnle Oual O'C Units RPD%REC% Range Anist Date Time Rad Alpha Spec Batch 557837 Curium-243/244 QC1201158319 Americium-241 Curium-242 Curium-243/244 QCI201158316 Americium-241 Uncert: +/-0.0495 TPU: +/-0.0496 U -0.0479 Uncert: +/-0.0542 TPU: +/-0.0545 LCS MB 24.5 Uncert: TPU: Uncert: TPU: 29.7 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.334+/-0.335 U 0.0761+/-0.149+/-0.149 25.4+/-2.47+/-4.16 U 0.0477+/-0.127+/-0.127 27.0+/-2.54+/-4.38 U 0.234+/-0.275+/-0.277 U 0.00+/-0.152+/-0.152 U -0.0551+/-0.0624+/-0.0628 pCi/g 879 Curium-242 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 91 (75%-125%)

(0%- 100%)104 (75%-125%)

Curium-243/244 QC1201158318 168404009 MS Americium-241 Curium-242 Curium-243/244 26.4 u -0.0851 Uncert: +/-0.136 TPU: +/-0.136 u -0.0253 Uncert: +/-0.0495 TPU: +/-0.0496 32.4 U -0.0479 Uncert: +/-0.0542 TPU: +1-0.0545 U 29.1+/-2.97+/-5.01 0.126+/-0.247+/-0.248 31.7+/-3.12+/-5.39 110 (75%-125%)

98 (75%-125%)

Rad Gas Flow Batch 556350 QC0201154645 168404003 DUP Strontium-90 QCl201154647 LCS Strontium-90 QC1201154644 MB Strontium-90 U -0.00343 Uncert: +/-0.0203 TPU: +/-0.0203 1.56 Uncert: TPU: U -0.00637+/-0.0152+/-0.0152 1.30+/-0.0563+/-0.0881 U 0.0176+/-0.018+/-0.018 pCi/g 0 (0%- 100%) BXFI 08/14/06 08:33 pCi/g pCi/g 83 (75%-125%)

Uncert: TPU: Page 102 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn QC Summary Workorder:

168404 Page 4 of 6 Parm na me NOM Samnle Oual QC Units RPD%REC% Range Anist Date Time Parmnarne NOM Rad Gas Flow Batch 556350 QC1201154646 168404003 MS Strontium-90 1.58 U Uncert: TPU:-0.00343+/-0.0203+/-0.0203 Rad Liquid Scintillation Batch 554580 QC12O1150562 Technetium-99 168340012 DUP U 0.0338 Uncert: +/-0.192 TPU: +/-0.192 U 1.29+/-0.0535+/-0.0813 0.266+/-0.226+/-0.226 13.6+/-0.496+/-0.599 pCi/g pCi/g 0 (0% -100%) EGDI QC1201150564 LCS Technetium-99 QC1201150561 MB Technetium-99 82 (75%-125%)

13.1 Uncert: TPU: Uncert: TPU: 13.0 U Uncert: TPU: U 0.0311+/-0.177+/-0 177 pCi/g pCi/g pCi/g 103 (75%-125%)

08/12/06 00:42 08/12/06 01:14 08/12/06 00:26 08/12/06 00:58 QC1201150563 168340012 MS Technetium-99 0.0338+/-0.192+/-0.192 12.0+/-0.523+/-0.602 92 (75%-125%)

Batch 554582 QC1201150570 168340011 DUP Tritium U 1.77 Uncert: +/-8.20 TPU: +/-8.20 U 1.62+/-7.47+/-7.47 pCi/g 0 (0% -100%) DFAI QC1201150572 LCS Tritium QC1201150569 MB Tritium 68.3 Uncert: TPU: Uncert: TPU: 61.3 U Uncert: TPU: 76.2+/-14.0+/-14.1 U 0.586+/-8.01+/-8.01 pCi/g pCi/g pCi/g II1 (75%-125%)

08/09/06 15:42 08/09/06 16:14 08/09/06 15:26 08/09/06 15:58 QC1201150571 168340011 MS Tritium 1.77+/-8.20+/-8.20 Batch 554583 QC1201150574 168404003 DUP Carbon-14 QC1201150576 LCS Carbon-14 QC1201150573 MB U 0.0937 Uncert: +/-0.0813 TPU: +/-0.0813 1J 61.8+/-12.2+/-12.3 0.0422+/-0.075+/-0.0751 7.14+/-0.508+/-0.520 101 (75%-125%)

pCi/g pCi/g 0 (0%- 100%) ATH2 08/10/06 01:39 08/10/06 03:00 7.27 Uncert: TPU: 98 (75%-125%)

Page 103 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 5 of 6 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Liquid Scintillation Batch 554583 Carbon-14 QC1201150575 168404003 MS Carbon- 14 Uncert: TPU: U -0.0315+/-0.0776+/-0.0776 pCi/g pCi/g 15.1 U Uncert: TPU: 0.0937+/-0.0813+/-0.0813 13.8+/-1.00+/-1.03 92 (75%-125%)

08/10/06 02:43 Batch 555722 QC1201153223 168340012 DUP Iron-55 QC1201153225 LCS Iron-55 QC)201153222 MB Iron-55 QC1201153224 168340012 MS Iron-55 U -26.5 Uncert: +/-65.1 TPU: +/-65.1 U 5.83+/-36.9+/-36.9 pCi/g 0 (0%- 100%) vAXPI 641 Uncert: TPU: Uncert: TPU: 717 U Uncert: TPU: 660+/-56.2+/-67.2 U 18.2+/-39.6+/-39.6 pCi/g pCi/g pCi/g 103 (75%-125%)

08/12/06 20:54 08/12/06 21:27 08/12/06 20:38 08/12/06 21:11-26.5+/-65.1+/-65.1 688+/-60.2+/-71.6 96 (75%-125%)

Batch 555723 QC1201153227 Nickel-63 168340012 DUP U 3.79 Uncert: +/-5.39 TPU: +/-5.40 U 6.68+/-7.43+/-7.43 pCi/g 0 (0% -100%) VlXPI QCl201153229 LCS Nickel-63 QC1201153226 MB Nickel-63 512 Uncert: TPU: Uncert: TPU: 530 U Uncert: TPU: 479+/-22.4+/-27.1 U 15.7+/-9.92+/-9.93 pCi/g pCi/g pCi/g 94 (75%-125%)

08/11/06 11:55 08/11/06 12:27 08/11/06 11:38 08/11/06 12:11 QC1201153228 168340012 MS Nickel-63 3.79+/-5.39+/-5.40 511+/-23.5+/-28.7 96 (75%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported Result is greater than value reported Page 104 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 6 of 6 Ni"Mn Qý I Ir n C Units RPD%-1, , jctýýZ REC% Range Anist Date Time A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U UI x Y h Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.** Indicates analyte is a surrogate compound.A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.Page 105 of 105 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2b Split Sample Assessment Forms (2 Pages)

Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey Area Survey 0006 Survey Discharge Canal#:9106 Unit#: Unit Name: Sample Plan or WPIR#: 2006-021 SML #: 9106-0006-007 Sample

Description:

Comparison of split samples collected from sample measurement location #03 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0006-007F the comparison sample was 9106-0006-007FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)Value Error Range Value Error Ratio Cs-137 1.38E-02 8.55E-03 2 NONE -9.80E-03 1.22E-02 0.71 N/A Co-60 1.58E-02 8.35E-03 2 NONE- 3.27E-02 1.36E-02 2.07 N/A Sr-90 -1.00E-02 6.25E-03 -2 NONE- 6.70E-03 8.55E-03 -0.67 N/A K-40 1.47E+01 5.55E-01 27 0.75 1.33 1.28E+01 5.40E-01 0.87 Y Comments/Corrective Actions: Neither Cs-137 nor Sr-90 were Table is provided to show acceptance criteria used identified in quantities greater than 2 standard deviations in to assess split samples.either sample. Co-60 was not identified in a quantity greater than 2 standard deviations in sample # -007F. This would Resolution Agreement Range account for resolutions of less than 4. In consideration of Cs- 4 7 0.50 2.00 137, Co-60 & Sr-90 results, guidance for agreement ranges, 8 15 0.60 1.66 obtained from USNRC Inspection Procedure 84750, does not 16 50 0.75 1.33 address resolution ratios less than 4, therefore, a determination 51 200 0.80 1.25 of acceptability for such rations cannot be made. Since K-40 was found to be present at an acceptable level of agreement, no > 200 0.85 1.18 further action is warranted.

Performed By: Date: Reviewed By: Date WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation Z Page I of I Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey 9106 Survey 0006 Survey Unit Discharge Canal Area#: Unit #: Name: Sample Plan or WPIR#: 2006-0021 SML #: 9106-0006-018 Sample

Description:

Comparison of split samples collected from sample measurement location #18 and analyzec using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0006-018F, tht comparison sample was 9106-0006-018FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)Value Error Range Value Error Ratio Cs-137 5.69E-02 1.33E-02 4 0.5 -2 2.47E-02 1.15E-02 0.43 N Co-60 1.20E-01 1.92E-02 6 0.5 2 9.93E-02 1.57E-02 0.83 Y Sr-90 2.23E-03 4.32E-03 1 N/A 3.18E-03 3.75E-03 1.43 N/A K-40 1.74E+01 3.93E-01 44 0.75 1.33 1.13E+01 4.27E-01 0.65 N 4. 4 4 4 4 4. 4. 4 4. 4 4 4. 4 4 4. 4 I I

  • fl I Comments/Corrective Actions: The agreement level for Cs-137 results may be explained by differences in realtive quantities of organic material constiuent to each sample. This does not necessarily indicate a problem with the sample preparation methodology.

On the other hand, the agreeement level for K-40 results may indicate an incomplete mixing of the sample aliqot during on-site sample prep. In consideration of Sr-90 results, guidance for agreement ranges, obtained from USNRC Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such rations cannot be made. This issue was dispositioned to the CR process on 9-25-06.Table is provided to show acceptance criteria used to assess split samples.Resolution

= Agreement Range 4 8 16 51 7 15 50 200> 200 0.50 0.60 0.75 0.80 0.85 2.00 1.66 1.33 1.25 1.18 WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation Page I of I DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2c Preliminary Data Forms (1 Page)

Health Physics Procedure GPP-GGGR-R5]2 1 -001 Attachment B, Rev. CY-00 I MAJOR Health Physics Procedure GPP-GGGR-R5121-OOl Attachment B, Rev. CY-001 MAJOR Preliminary Data Review Form -Samples for the Sign Test Survey Unit: 9106- 0006 Survey Unit Name: Discharge Canal Classification:

Survey Media: Type of Survey: Type of Measurement:

Number of Measurements:

Operational DCGL: 2 Soil Final Status Survey Radionuclide Specific 15 1 BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Sr-90 Minimum Value: -2.82E-02

-1.34E-02

-1.OOE-02 Maximum Value: 5.20E-01 I1.94E+00 1.95E-02 Mean: 1.60E-01 3.43E-01 2.68E-03 Median: 1.30E-01 1.02E-01 1.67E-03 Standard Deviation:

1.69E-01 5.13E-01 7.5 1E-03 RADIONUCLIDE CONCENTRATION (pCi/g)NUMBER 9106-0006-OOIF 9106-0006-003F 9106-0006-004F 9106-0006-005F 9106-0006-006F 9106-0006-007F 9106-0006-008F 9106-0006-009F 9106-0006-01OF 9106-0006-01 IF 9106-0006-012F 9106-0006-014F 9106-0006-015F 9106-0006-019F 9106-0006-020F Cs-137-7.55E-04 1.70E-01 9.60E-02 4.09E-01 1.30E-01 1.38E-02 2.95E-01 2.26E-01 5.20E-01 3.12E-03 2.71 E-02 1.79E-01 3.43E-01-2.82E-02 1.28E-02 Co-60-3.31 E-03 7.22E-01 4.38E-02 1.94E+00 2.41 E-01 1.58E-02 6.35E-01 1.02E-01 6.31 E-01 4.70E-02 6.08E-03 4.86E-01 2.21E-01-1.34E-02 7.34E-02 Sr-90 5.37E-04 1.45E-02 4.27E-03 1.95E-02 7.50E-04-1.OOE-02 4.02E-03 7.88E-03 7.15E-03 2.44E-03-2.02E-03-1.04E-03-3.81 E-03 1.67E-03-5.59E-03 Identified?

N Y Y Y Y N Y Y Y N Y Y Y N N Identified?

Identified?

N N Y N N N Y N Y N N N Y N Y N Y Y Y N N N Y N Y N N N N N&I1 E24'a Performed By: Independent Review: Date: /10-90-,,'

Date: 6 DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2d.Graphical Representation of Data (6 Pages)

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OO1 Attachment C Quantile Plot For Cesium -137 Survey Unit: 9106-0006 Survey Unit Name: Discharge Canal Mean: 1.60E-01 pCi/g 6.OOE-01 ,,5.00E-01

" O 4.OOE-01 '-0 3.OOE-01 ."- 2.OOE-01 1.OOE-01 " 0 0.OOE+00 0 61. 10-1.00E-01

)204 , 011 Percentage Cs-1 37 Rank Percentage

-2.82E-02 1 3 %-7.55E-04 2 10 %3.12E-03 3 17 %1.28E-02 4 23 %1.38E-02 5 30 %2.71 E-02 6 37 %9.60E-02 7 43 %1.30E-01 8 50 %1.70E-01 9 57 %1.79E-01 10 63 %2.26E-01 11 70 %2.95E-01 12 77 %3.43E-01 13 83 %4.09E-01 14 90 %5.20E-01 15 97 %Prepared By: Reviewed By: i5A t~Zt Date: /0 0 r 6ZDae I ý C3; ý 5 4 Date:

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Cobalt -60 Survey Unit: Survey Unit Name: Mean: 9106-0006 Discharge Canal 3.43E-01 pCi/g 2.50E+00 -.. 2.OOE+00 o 1.50E+00 0 1.00E+00 0 00.OOE+00

-.20 40 60 80 10 Percentage Co-60 Rank Percentage

-1.34E-02 1 3 %-3.31E-03 2 10 %6.08E-03 3 17 %1.58E-02 4 23 %4.38E-02 5 30 %4.70E-02 6 37 %7.34E-02 7 43 %1.02E-01 8 50 %2.21 E-01 9 57 %2.41E-01 10 63 %4.86E-01 11 70 %6.31E-01 12 77 %6.35E-01 13 83 %7.22E-01 14 90 %1.94E+00 15 97 %Prepared By: Reviewed By: 6: ~ Pe~A,~L Date: /0 -, , Date: jr r Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Strontium

-90 Survey Unit: 9106-0006 Survey Unit Name: Discharge Canal Mean: 2.68E-03 pCi/g 2.50E-02-2.OOE-02 -.1.50E-02 1.OOE-02 -5.00E-03O.OOE+00 , ----o-5.00E-03

  • 2 _ 4 6 _0 1 0-1.OOE-02-1.50E-02 Percentage Sr-90 Rank Percentage

-1.OOE-02 1 3 %-5.59E-03 2 10 %-3.81E-03 3 17 %-2.02E-03 4 23 %-1.04E-03 5 30 %5.37E-04 6 37 %7.50E-04 7 43 %1.67E-03 8 50 %2.44E-03 9 57 %4.02E-03 10 63 %4.27E-03 11 70 %7.15E-03 12 77 %7.88E-03 13 83 %1.45E-02 14 90 %1.95E-02 15 97 %Prepared By: c~ejZ9~sOT Date: 10- 0-,z Date: Reviewed By:

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cs -137 Survey Unit: 9106-0006 Survey Unit Name: Discharge Canal Mean: 0.160 pCi/g 8 g4-Cr 0*u. 2 0.10 0.20 0.30 0.40 0.50 0.60 Upper End Value (pCi/g)Upper End Observation Observation

%Value Frequency Frequency 0.10 7 47%0.20 3 20%0.30 2 13%0.40 1 7%0.50 1 7%0.60 1 7%Total 15 100%Prepared By: b.,0- /-Date: / -2 &' -0, Reviewed By: Reviewed By: Date: Date: 42ýex, '

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cobalt-60 Survey Unit: 9106-0006 Survey Unit Name: Discharge Canal Mean: 0.343 pCi/g 10 0r 0)0*U.8 6 4 2 0 I I 4.I I FELH I ..'0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 Upper End Value (pCilg)Upper End Observation Observation

%Value Frequency Frequency 0.00 2 13%0.25 8 53%0.50 1 7%0.75 3 20%1.00 0 0%1.25 0 0%1.50 0 0%1.75 0 0%2.00 1 7%Total 15 100%Prepared By: Reviewed By:~A4 Date: 149 -101a4 Date: / v3e)z- C Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Sr -90 Survey Unit: 9106-0006 Survey Unit Name: Discharge Canal Mean: 0.003 pCi/g 7 6 a3-o~r3 1- 2I 0 0.000 0.005 0.010 0.015 0.020 Upper End Value (pCi/g)Upper End Observation Observation

%Value Frequency Frequency 0.000 5 33%0.005 6 40%0.010 2 13%0.015 1 7%0.020 1 7%Total 15 100%Prepared By: Date: /a --? a -og/, Reviewed By:-i Date: x DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2e Sign Test Calculation (1 Page)

Health Physics Procedure GPP-GGGR-R5121

-000 Attachment A, Rev. CY-00 I MAJOR Health Physics Procedure GPP-GGGR-R5 121-000 Attachment A, Rev. CY-00 1 MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes Survey Unit Number: 0006 Survey Unit Name: Discharge Canal WP&IR#: 2006-02 1 IYPE I (a error):0.01 TYPE I (b error):0.05 I Classification

2 Radionuclides:

Survey Design DCGL (pCi/g): Cs-137 Co-60 Sr-90 1.05 5.38 2.59 Results Cs-137-7.55E-04 1.70E-01 9.60E-02 4.09E-0 1 1.30E-01 1.38E-02 2.95E-01 2.26E-01 5.20E-01 3.12E-03 2.71E-02 1.79E-01 3.43E-0 1-2.82E-02 1.28E-02 Results Co-60-3.31 E-03 7.22E-01 4.38E-02 1.94E+00 2.41 E-0 1 1.58E-02 6.35E-01 1.02E-0 1 6.3 1E-0I 4.70E-02 6.08E-03 4.86E-01 2.2 1E-01-1.34E-02 7.34E-02 Results Sr-90 5.37E-04 1.45E-02 4.27E-03 1.95E-02 7.50E-04-1.00E-02 4.02E-03 7.88E-03 7.15E-03 2.44E-03-2.02E-03-1.04E-03-3.81E-03 1.67E-03-5.59E-03 Weighted Sum (Ws)-9.08E-04 3.24E-01 3.88E-02 8.43E-01 1.18E-01-8.24E-04 3.04E-01 8.89E-02 3.47E-0 1 2.1OE-02 5.47E-03 2.20E-0 I 1.45E-01-8.83E-03 2.54E-02 DCGL-Result 1.00E+00 6.76E-0 1 9.6 1E-01 1.57E-01 8.82E-01 1.00E+00 6.96E-01 9.11E-01 6.53E-01 9.79E-01 9.95E-01 7.80E-01 8.55E-01 1.01E+00 9.75E-01 Sign Number of Positive Differences (S+): 15 Critical Value: 11 Survey Unit: Meets Acceotance Criterion&- / xs,ýZ//Performed By: Date: 0 -06, Date: 15 Independent Review:-7 ° ---

DISCHARGE CANAL SURVEY UNIT 9106-0006 RELEASE RECORD Attachment 2f COMPASS DQA Surface Soil Report with Retrospective Power Curve (3 Pages)

DQA Surface Soil Report Assessment Summary Site: Planner(s):

Survey Unit Name: Report Number: Survey Unit Samples: Reference Area Samples: Test Performed:

Judgmental Samples: Assessment

==

Conclusion:==

9106-0006 (19 mrem/yr)Dale Randall 9106-0006 1 15 0 Sign Test Result: Not Performed 0 EMC Result: Not Performed Reject Null Hypothesis (Survey Unit PASSES)Retrospective Power Curve-0.9.t0.8=.I~0.7 0.5 , 0.6'** 0.6 0.4 ,- 0.3 0.2 0 0.1 0* z~zIz ----____ ______.1 ____* -.1-u- --________* .4.I. --______-4-I-_ _ _* _ -'SI _ZijIll ___ --___ ZiZIL ___-i-I- --______ 'I _____Z~ZL_--___

0.0 0.2 0.4 0.6 0.8 1.0 Unity Rule Sum-of-Ratios, including backgiund--Prospective Power E 1-beta .Actual Power-LBGR , , Estimated Power DCGL ---- Retrospective Power 1.2 COMPASS vl.0.0 1013012006 Page1I DQA Surface Soil Report Survey Unit Data NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9106-0006-001 F 9106-0006-003F 9106-0006-004F 9106-0006-005F 9106-0006-006F 9106-0006-007F 9106-0006-008F 9106-0006-009F 9106-0006-01 OF 9106-0006:01 1F 9106-0006-012F 9106-0006-014F 9106-0006-015F 9106-0006-019F 9106-0006-020F Type S S S S S S S S S S S S S S S Co-60 (pCi/g)0 0.72 0.04 1.94 0.24 0.02 0.64 0.1 0.63 0.05 0.01 0.49 0.22-0.01 0.07 Cs-137 (pCi/g)0 0.17 0.1 0.41 0.13 0.01 0.3 0.23 0.52 0 0.03 0.18 0.34-0.03 0.01 SrY-90 (pCi/g)0 0.01 0 0.02 0-0.01 0 0.01 0.01 0 0 0 0 0-0.01 Modified Data (Unity Rule SOR)NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9106-0006-001 F 9106-0006-003F 9106-0006-004F 9106-0006-005F 9106-0006-006F 9106-0006-007F 9106-0006-008F 9106-0006-009F 9106-0006-01 OF 9106-0006-011 F 9106-0006-012F 9106-0006-014F 9106-0006-015F 9106-0006-019F 9106-0006-020F Type S S S S S S S S S S S S S S S Sum-of-Ratios (SOR)0 0.29 0.03 0.75 0.11 0 0.27 0.08 0.31 0.02 0 0.2 0.13-0.01 0.02 COMPASS vl.0.0 10130/2006 Page 2

-'q VýJ DQA Surface Soil Report Basic Statistical Quantities Summary Statistic Survey Unit Background DQO Results Sample Number 15 N/A N=13 Mean (SOR) 0.15 N/A 0.15 Median (SOR) 0.08 N/A N/A Std Dev (SOR) 0.20 N/A 0.1 High Value (SOR) 0.75 N/A N/A Low Value (SOR) -0.01 N/A N/A COMPASS vl.0.0 1013012006 Page 3