Text

I I N N D D I I A A N N A A A A N N D D M M I I C C H H I I G G A A N N P P O O W W E E R R D D.. C C.. C C O O O O K K N N U U C C L L E E A A R R P P L L A A N N T T U U P P D D A A T T E E D D F F I I N N A A L L S S A A F F E E T T Y Y A A N N A A L L Y Y S S I I S S R R E E P P O O R R T TRevision:17Table:9.8-2 Page:1 of 4COMPRESSED AIR SYSTEM DESCRIPTIVE INFORMATION 1PLANT AIR SYSTEMPlant Air CompressorNumber2 (one for each unit)TypeCentrifugalDischarge Pressure, psig 100Discharge Temperature (approximate)F 266Capacity, icfm (with inlet conditions of 14.3 psia and 110 o F)1,485Plant Air compressor AftercoolerNumber1 per compressorTypeShell & TubeTube Side Flow, icfm (air)1,500Shell Side Flow, gpm (water) 23Shell Side Design Pressure, psig150Tube Side Design Pressure, psig 150Shell MaterialCarbon SteelTube MaterialAdmiraltyDesign CodeASME B&PV Code Section VIII Plant Air ReceiverNumber2 (one for each unit)Capacity, ft 3 200Design Pressure, psig125Design Temperature, F 300Operating Pressure, psig100Operating Temperature, F 105MaterialCarbon SteelDesign CodeASME B&PV Code Section VIII 1 The information in this Table reflects manufacturer equipment ratings and specifications for the compressed airsystems components. These values do not necessarily reflect design basis values for the compressed air systems.

I I N N D D I I A A N N A A A A N N D D M M I I C C H H I I G G A A N N P P O O W W E E R R D D.. C C.. C C O O O O K K N N U U C C L L E E A A R R P P L L A A N N T T U U P P D D A A T T E E D D F F I I N N A A L L S S A A F F E E T T Y Y A A N N A A L L Y Y S S I I S S R R E E P P O O R R T TRevision:17Table:9.8-2 Page:2 of 4COMPRESSED AIR SYSTEM DESCRIPTIVE INFORMATIONCONTROL AIR SYSTEMControl Air CompressorNumber2 (one for each unit)TypeReciprocatingNominal Discharge Pressure, psig 100Discharge Temperature, F 320Capacity, icfm338, @29.92 in HgA inlet, 480 RPM, 100 psigdischargeControl Air Compressor AftercoolerNumber1 per compressorTypeShell & TubeTube Side Flow, icfm(air) 338Shell Side Flow, gpm (water)5Shell Side Design Pressure, psig 150Tube Side Design Pressure, psig150Shell MaterialCarbon SteelTube MaterialAdmiraltyDesign CodeASME B&PV Code Section VIII Control Air Receiver (Wet Control Air)Number2 (one for each unit)Capacity, ft 3 500Design Pressure, psig 125Design Temperature, F 300Operating Pressure, psig 100Operating Temperature, F 95 MaterialCarbon SteelDesign CodeASME B&PV Code Section VIII I I N N D D I I A A N N A A A A N N D D M M I I C C H H I I G G A A N N P P O O W W E E R R D D.. C C.. C C O O O O K K N N U U C C L L E E A A R R P P L L A A N N T T U U P P D D A A T T E E D D F F I I N N A A L L S S A A F F E E T T Y Y A A N N A A L L Y Y S S I I S S R R E E P P O O R R T TRevision:17Table:9.8-2 Page:3 of 4COMPRESSED AIR SYSTEM DESCRIPTIVE INFORMATIONCONTROL AIR SYSTEM (CONT'D)

Control Air PrefilterNumber4 (two for each unit in parallel strings)Capacity, scfm325Inlet pressure, psig 100Inlet temperature, F (saturated) 95Effluent Dewpoint F(at design pressure)

-40Retention Size, microns5TypeAdsorbentControl Air DrierNumber8 (four for each unit in two parallel strings)Capacity, scfm325Dew Point at 100 psig, F-40TypeConvection Control Air After FilterNumber4 (two for each unit in parallel)Capacity, scfm840Retention Size, microns 4TypeAdsorbent Control Air Receiver (Dry Control Air)Number4 (two for each unit in parallel strings)Capacity, ft 3 500Design Pressure, psig 125Design Temperature, F 300Operating Pressure, psig 100Operating Temperature, F 105 MaterialCarbon SteelDesign CodeASME B&PV Code Section VIII I I N N D D I I A A N N A A A A N N D D M M I I C C H H I I G G A A N N P P O O W W E E R R D D.. C C.. C C O O O O K K N N U U C C L L E E A A R R P P L L A A N N T T U U P P D D A A T T E E D D F F I I N N A A L L S S A A F F E E T T Y Y A A N N A A L L Y Y S S I I S S R R E E P P O O R R T TRevision:17Table:9.8-2 Page:4 of 4COMPRESSED AIR SYSTEM DESCRIPTIVE INFORMATIONCONTROL AIR SYSTEM (CONT'D)Backup Plant Air Compressor with Integral Skid Mounted Aircooled AftercoolerNumber1 (common for both units)TypeRotary ScrewNominal Discharge Pressure 100Discharge Temperature (approximate) o F 108Capacity, icfm (with inlet conditions of 14.5 psia and 80 o F)668Backup Plant Air Compressor Air ReceiverNumber 1Capacity, ft 3 100Design Pressure, psig 150Design temperature, o F 450Operating Pressure, psig 100Operating Temperature, o F 105 MaterialCarbon SteelDesign CodeASME B & PV Code section VIII