ML16341C514

From kanterella
Jump to navigation Jump to search
7 to Updated Final Safety Analysis Report, Chapter 9, Table 9.8-2
ML16341C514
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16341C514 (4)


Text

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17 Table:

9.8-2 Page:

1 of 4 COMPRESSED AIR SYSTEM DESCRIPTIVE INFORMATION1 PLANT AIR SYSTEM Plant Air Compressor Number 2 (one for each unit)

Type Centrifugal Discharge Pressure, psig 100 Discharge Temperature (approximate)°F 266 Capacity, icfm (with inlet conditions of 14.3 psia and 110oF) 1,485 Plant Air compressor Aftercooler Number 1 per compressor Type Shell & Tube Tube Side Flow, icfm (air) 1,500 Shell Side Flow, gpm (water) 23 Shell Side Design Pressure, psig 150 Tube Side Design Pressure, psig 150 Shell Material Carbon Steel Tube Material Admiralty Design Code ASME B&PV Code Section VIII Plant Air Receiver Number 2 (one for each unit)

Capacity, ft3 200 Design Pressure, psig 125 Design Temperature, °F 300 Operating Pressure, psig 100 Operating Temperature, °F 105 Material Carbon Steel Design Code ASME B&PV Code Section VIII 1 The information in this Table reflects manufacturer equipment ratings and specifications for the compressed air systems components. These values do not necessarily reflect design basis values for the compressed air systems.

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17 Table:

9.8-2 Page:

2 of 4 COMPRESSED AIR SYSTEM DESCRIPTIVE INFORMATION CONTROL AIR SYSTEM Control Air Compressor Number 2 (one for each unit)

Type Reciprocating Nominal Discharge Pressure, psig 100 Discharge Temperature, °F 320 Capacity, icfm 338, @29.92 in HgA inlet, 480 RPM, 100 psig discharge Control Air Compressor Aftercooler Number 1 per compressor Type Shell & Tube Tube Side Flow, icfm(air) 338 Shell Side Flow, gpm (water) 5 Shell Side Design Pressure, psig 150 Tube Side Design Pressure, psig 150 Shell Material Carbon Steel Tube Material Admiralty Design Code ASME B&PV Code Section VIII Control Air Receiver (Wet Control Air)

Number 2 (one for each unit)

Capacity, ft3 500 Design Pressure, psig 125 Design Temperature, °F 300 Operating Pressure, psig 100 Operating Temperature, °F 95 Material Carbon Steel Design Code ASME B&PV Code Section VIII

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17 Table:

9.8-2 Page:

3 of 4 COMPRESSED AIR SYSTEM DESCRIPTIVE INFORMATION CONTROL AIR SYSTEM (CONT'D)

Control Air Prefilter Number 4 (two for each unit in parallel strings)

Capacity, scfm 325 Inlet pressure, psig 100 Inlet temperature, °F (saturated) 95 Effluent Dewpoint °F(at design pressure)

-40 Retention Size, microns 5

Type Adsorbent Control Air Drier Number 8 (four for each unit in two parallel strings)

Capacity, scfm 325 Dew Point at 100 psig, °F

-40 Type Convection Control Air After Filter Number 4 (two for each unit in parallel)

Capacity, scfm 840 Retention Size, microns 4

Type Adsorbent Control Air Receiver (Dry Control Air)

Number 4 (two for each unit in parallel strings)

Capacity, ft3 500 Design Pressure, psig 125 Design Temperature, °F 300 Operating Pressure, psig 100 Operating Temperature, °F 105 Material Carbon Steel Design Code ASME B&PV Code Section VIII

IINNDDIIAANNAA AANNDD M MIICCHHIIGGAANN PPOOW WEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision:

17 Table:

9.8-2 Page:

4 of 4 COMPRESSED AIR SYSTEM DESCRIPTIVE INFORMATION CONTROL AIR SYSTEM (CONT'D)

Backup Plant Air Compressor with Integral Skid Mounted Aircooled Aftercooler Number 1 (common for both units)

Type Rotary Screw Nominal Discharge Pressure 100 Discharge Temperature (approximate)oF 108 Capacity, icfm (with inlet conditions of 14.5 psia and 80oF) 668 Backup Plant Air Compressor Air Receiver Number 1

Capacity, ft3 100 Design Pressure, psig 150 Design temperature, oF 450 Operating Pressure, psig 100 Operating Temperature, oF 105 Material Carbon Steel Design Code ASME B & PV Code section VIII