ML063400434

From kanterella
Revision as of 05:25, 11 November 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Haddam Neck Plant, Final Status Survey Final Report Phase Iv, Appendix A3, Survey Unit Release Record 9106-0003, Discharge Canal
ML063400434
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 11/13/2006
From: Newson C
Connecticut Yankee Atomic Power Co
To:
NRC/FSME
References
9106-0003
Download: ML063400434 (226)


Text

Bok4 f1 Final Status Survey Final Report Phase IV Appendix A3 Survey Unit Release Record 9106-0003, Discharge Canal November 2006 CYAPCO FINAL STATUS SURVEY RELEASE RECORD DISCHARGE CANAL SURVEY UNIT 9106-0003%-LZ X Prepared By: Reviewed By: Approved By: FS gineer Date: /a-2 5,'-o1 Date: //"/3 Date:____Technical Support Manager Revision 0 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD TABLE OF CONTENTS 1. SURVEY UNIT DESCRIPTION

.................................................................

3 2. CLASSIFICATION BASIS ......................................................................

3 3. DATA QUALITY OBJECTIVES (DQO) ....................................................

5 4. SURVEY DESIG N .....................................................................................

8 5. SURVEY IMPLEMENTATION

................................................................

10 6. SURVEY RESULTS ...............................................................................

11 7. QUALITY CONTROL .............................................................................

13 8. INVESTIGATIONS AND RESULTS ......................................................

14 9. REMEDIATION AND RESULTS .............................................................

14 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN ....................

14 11. DATA QUALITY ASSESSMENT (DQA) .................................................

14 12. A NO M A LIES ...........................................................................................

15 13. CO NCLUSIO N .......................................................................................

15 14. ATTACHM ENTS .....................................................................................

16 14.1 Attachment 1 -Figures (6 pages including cover)14.2 Attachment 2 -Sample and Statistical Data (194 pages including covers)Revision 0 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9106-0003 (Discharge Canal) is designated as Final Status Survey (FSS) Class 2 and consists of approximately 8,292 m 2 ( 2.05 acres) of water covered sediment in an area located approximately 0.28 miles from the reference coordinate system benchmark used at the Haddam Neck Plant (HNP)(see Attachment 1, Figure 1). The Discharge Canal is a man-made mile long waterway that runs parallel to, and ultimately communicates with the Connecticut River. The Discharge Canal is subdivided into fifteen (15) survey units which includes two (2) permanent wetland areas for FSS purposes.

With"called north" oriented with the north to south flow of the Connecticut River, the survey unit is bounded as follows: Discharge Canal Survey Unit 9106-0002 is to the north, land surface area Survey Unit 9521 is to the east, Discharge Canal Survey Unit 9106-0004 is to the south and Survey Area 9520 is to the west. The survey unit comprises the canal sediments to the deeper of three (3)feet or the original construction depth. It extends up the canal banks to the mean high water level.The reference coordinates associated with this survey unit are E010 through E015 by S084 through S092 (refer to License Termination Plan Section 5.4.4).The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10,"Survey Unit Classification. " The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9106-0003 as Class 2 in April 2006.The "Classification Basis Summary" conducted for this survey unit consisted of: a) A review of the 1OCFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment (HSA) Supplement, " c) Historic and current survey records review, d) Visual inspections and a "walkdown." e) Formal or informal interviews with cognizant personnel.

A review of the 1 OCFR50.75(g)(1) database report identifies a number of events that may have impacted this survey unit. Several events indicated the potential for plant related contamination in the survey unit. These included a number of primary side system to secondary side system leakage events, contamination Revision 0 3 Revision 0 3 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD found to be present in secondary side systems and components, and unmonitored spills that drained to the discharge canal. In 1986, samples were taken from the legacy dredge spoils removed in 1979 dredged spoils area and from recently dredged canal sediment.

The sample analyses indicated that the concentrations of Cs-137, Co-60 and other radionuclides were a small fraction of the DCGLs for those nuclides that could be identified by gamma spectroscopy. (refer to NE-86-RA-1142 dated 11-13-86).

None of the available historical information reviewed would support a conclusion that any residual activity in this survey unit was present at concentrations greater than the respective DCGLs.Additional information was provided by several historical documents, including the "Results of Scoping Survey", (completed 9/1/98), the "Historical Site Assessment", and the HSA Supplement (dated 6-30-00).

These documents presented the results of several sediment samples taken in 1997. These sample results indicated concentrations of 0.5 pCi/g for Co-60, 0.024 pCi/g for Cs-134 and 0.722 pCi/g for Cs-137.A review of the "Initial and Supplemental Characterization Reports" as well as the previous "Classification Basis Summaries" provided no additional information pertinent to classification.

Characterization was performed by Site Closure personnel in April and May of 2004 to obtain the necessary data of sufficient data quality for final status survey (FSS) planning purposes.

Fifteen (15) samples were initially obtained by biased sampling throughout the area. The samples were analyzed off-site using gamma spectroscopy.

Hard-to-Detect analyses were also conducted on two (2) of the fifteen (15) samples. The only plant-related dosimetrically significant radionuclides identified in the samples were Cesium- 137 and Cobalt-60 (refer to Table 1).Table I -Basic 'Statitical Cs-137 and Co-60 fromn the ChrceiainSte Minimum Value: -6.28E-03

-1.47E-02 Maximum Value: 4.44E-01 1.49E+00 Mean: 9.06E-02 1.59E-01 Median: 3.30E-02 7.46E-03 Standard Deviation:

1.32E-01 3.85E-01 NOTE: The Operational DCGLs are 5.38 pCi/g for Cs-137, 2.59 pCi/g for Co-60; these are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE The FSS Engineer performed a visual inspection and walkdown during May 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low Revision 0 4 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational DCGLs justifying a final survey unit classification of Class 2 (refer to Section 3).3. DATA QUALITY OBJECTIVES (DQO)FSS design and planning is based on the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM).

A summary of the main features of the DQO process are provided herein.The DQO process incorporates hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis.

Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition.

The baseline condition is technically known as the null hypothesis.

Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection.

In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria.

Rejection of the null hypothesis would satisfy the release criteria objective of the FSS.The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9106-0003 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.

This is done through the development of Derived Concentration Guideline Levels (DCGLs). The DCGLs represent the concentration of radioactivity above background, equivalent to a dose-based release criterion and is presented in terms of surface or mass activity concentrations.

Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), for existing groundwater radioactivity and for future groundwater radioactivity that will be contributed by building foundations and footings.As described in detail in the LTP, the dose model applied to the discharge canal presumes that the canal sediments are dredged to a depth of three (3) feet and spread for the planting of crops per the Resident Farmer Scenario.Consequently, the soil DCGLs are directly applied to the canal sediment media which are sampled by coring to a nominal depth of three (3) feet.The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing Revision 0 5 Revision 0 5 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.Equation 1: HTotal=HSoil (sediment)

+ HExisting GW + HFuture GW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.This survey unit is affected by existing groundwater (reference CY memo ISC 06-024). The dose contribution from existing groundwater is bounded to be less than two (2) mrem/yr TEDE, based on field data.This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings remaining within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contributions from future groundwater, the third component is, therefore, zero (0) mrem/yr TEDE.Equation 2: 19 mrem/yr~otaj=

17 mrem/yrsoi 1+2 mrem/yrExisting GW+O mrem/yrFuture GW The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2 Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.Revision 0 6 Revision 0 6 DISCHARGE CANAL SURVEY UNIT 9 106-0003 RELEASE RECORD 1-1-.5 4.1 bU-t-O 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+O1 6.96E-0I Fe-55 2.74E+04 1.86E+04 1 .1 OE+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+O1 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+O1 8.57E+00 5.04E-01 Ag- 108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+O1 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+O I Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE (3) The Operational DCGL is equivalent to seventeen (17) mrem/yr TEDE (4) The required MDC is equivalent to one (1) mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.

Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.

Characterization was performed in April and May of 2004 as discussed in Section 2. Cesium-137 and Cobalt-60 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137 and Co-60 are provided in Table 1.As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration

(<MDC) were not accepted for FSS. Sample report Revision 0 7 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. To assist the FSS Engineers when preparing survey plans for FSS, guidance is provided in Procedure RPM 5.1-11,"Preparation of Final Status Survey Plans". By design, the FSSP meets the ALARA criteria for soils as specified in Chapter 4 of the LTP.Characterization was performed by Site Closure personnel in April and May 2004 to determine existing conditions and obtain radiological data for Final Status Survey (FSS). The DQO process determined that Cs-137 and Co-60 would be the radionuclides of concern (refer to Section 3). The sum of fractions or unity rule would be used with the individual Operational DCGLs because multiple radionuclides (Cs-137 and Co-60) were considered in the survey design. Other radionuclides identified during FSS would be evaluated to ensure adequate survey design and compliance with the unity rule.Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs". Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since the survey unit is a Class 2 and discrete, elevated areas of contamination were not expected.The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

This approach was conservative since it included background Cs-137 as part of the sample set.The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Samples for Final Status Survey. " The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.5 to maintain the relative shift (A/a) in the range of 1 and 3. The resulting relative shift was 1.9. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.Revision 0 8 Revision 0 8 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD Survey design specified sixteen (16) sediment samples for non-parametric statistical testing.The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey. " Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.STable 3 -Sampl~e Wasurment Locations N~ith Associated

(,PS Coordinates

..........

=l Northng L asting 9106-0003-OOIF 235918.25 669524.39 9106-0003-002F 235918.25 669605.02 9106-0003-003F 235848.42 669484.07 9106-0003-004F 235848.42 669564.70 9106-0003-005F 235848.42 669645.33 9106-0003-006F 235848.42 669725.96 9106-0003-007F 235778.60 669605.02 9106-0003-008F 235778.60 669685.64 9106-0003-009F 235778.60 669766.27 9106-0003-OIOF 235778.60 669846.90 9106-0003-011 F 235778.60 669927.53 9106-0003-012F 235778.60 670008.16 9106-0003-013F 235708.77 669806.59 9106-0003-014F 235708.77 669887.22 9106-0003-015F 235708.77 669967.85 9106-0003-016F 235708.77 670048.47 There was to be one (1) sediment core to be taken as a judgmental sample. The location was selected based on its proximity to the outfall of a culvert which drains from a low-lying area along the Independent Spent Fuel Storage Installation (ISFSI) haul road.Although Procedure RPM 5.1-11 specifies that 5% of the samples must be selected for HTD analysis, four (4) sediment samples were analyzed for HTDs, exceeding the percentage required.

Two (2) samples for statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel"RAND" function.

In addition, two (2) samples, which were determined to contribute the greatest dose based on gamma only analyses were also selected Revision 0 9 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD for HTD analyses.

This number of HTD analyses exceeded the 5%requirement.

Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in Table 2.The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey, " included the collection of two (2) sediment samples for "split sample" analysis by the off-site laboratory.

These locations were selected randomly using the Microsoft Excel"RAND" function.

The number of quality control samples exceeded the 5%requirement.

Section 5.7.3.2.6 of the LTP specifies that scanning is not required for the FSS of the Discharge Canal. Table 4 provides a synopsis of the survey design.Survey Unit Area d on AutoUAD-LI and Visual Sample Plan calculations Type I and Type 2 errors were 0.05, Number of 16 sigma was 0.257 the LBGR was set to 0.5 Measurements to maintain Relative Shift in the range of I and 3, Relative Shift was 1.9 Grid Spacing 24.5 Based on triangular grid Design DCGL 3.16 pCi/g Cs-137 To achieve 10 mrem/yr TEDE 1.52 pCi/g Co-60 Operational 5.38 pCi/g Cs-137 To achieve 17 mrem/yr TEDE (2) to demonstrate compliance with DCGL 2.59 pCi/g Co-60 Equation 2 of this Release Record Scan Coverage N/A The LTP exempts this area Sediment Investigation 5.38 pCi/g Cs-137 The Operational DCGL meets the LTP Level 2.59 pCi/g Co-60 criteria for a Class 2 survey unit (1) The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 as the total dose from existing and future groundwater had not been established at the time of planning the FSS (2) The allowable dose for soil in this survey unit is seventeen (17) mrem/yr TEDE as the total dose from existing and future groundwater has been established (reference CY memo ISC 06-024)5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0021.

The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.Revision 0 10 Revision 0 10 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD Using GPS coordinates, sample measurement locations were identified in NAD 1927 coordinates that were supplied to the sampling vendor, Ocean Survey Inc. (OSI) of Old Saybrook, Connecticut.

Discharge Canal sampling was accomplished using direct push technology to collect composite samples of bottom and average high water mark sediments.

Sediment cores from the Discharge Canal were obtained by OSI using a vibrating corer that is platform mounted on a sampling vessel. The core barrel was a three (3) inch diameter thin-walled aluminum tube which also serves as a core liner (ten (10) feet or less). A core catcher was available to prevent the sample from sliding out of the bottom of the tube. Vessel positioning and the determination of sample locations will be accomplished using a global positioning system (GPS)interfaced with a navigation and data logging system.After extraction, water was drained from above the sample by drilling holes above the sediment.

The liner was cut, capped, sealed, labeled and turned over from the Ocean Surveys, Inc. to site personnel who processed and controlled the samples under Chain-of-Custody (COC). Rinsing of the barrel and associated equipment was performed between sampling events. New aluminum tubes were used to prevent cross-contamination of subsequent samples.The sixteen (16) sediment samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples ".Four (4) samples (9106-0003-004F, 9106-0003-008F, 9106-0003-0014 and 9106-0003-015F) were selected for HTD radionuclide analysis by the off-site laboratory.

Two (2) of these samples (008F and 014F) were selected at random. The others were selected based on being the most dosimetrically significant samples from spectroscopic gamma analyses.One (1) biased sediment sample (9106-0003-017F) was collected and analyzed by the offsite laboratory for gamma spectroscopy.

The implementation of survey specific quality control measures included the collection of two (2) split samples at locations 9106-0003-004F and 9106-0003-01OF for "split sample" analysis by the off-site laboratory.

6. SURVEY RESULTS The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL) -Charleston, South Carolina.

The laboratory analyzed the sixteen (16) samples taken for non-parametric statistical testing and the associated duplicates using gamma spectroscopy.

Gamma Revision 0 I1I Revision 0 11 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD spectroscopy analysis was performed to the required MDC. Gamma spectroscopy results identified some radionuclides meeting the acceptance criteria for detection (i.e., a result greater than two standard deviations uncertainty).

All could be de-selected or excluded using the 5% and 10% rule described in Section 4.Cesium-137 was identified in fourteen (14) and Co-60 was identified in eleven (11) of the sixteen (16) samples.None of the samples exceeded the Operational DCGL. Gamma spectroscopy sample analysis did not require further investigation.

A summary of the sample results is provided in Table 5.I Tabile 2;- Summary ot'Svdinieit Sam ple Results.'am'p&Num-r:'

1C-j3 71 Co-60 Fraction of tbe Operational Do" I-~'Sapl ume P'i' 00 Nuclides of Unity>p/ ?~I concern (Sign Test) (2)9106-0003-001 F 1.28E-0 I 1.07E-01 1.1 IE-01 1.48E-01 9106-0003-002F 4.37E-02 1.89E-02 2.63E-02 6.35E-02 9106-0003-003F 3.93E-02 2.45E-02 2.86E-02 6.58E-02 9106-0003-004F 2.92E-01 7.43E-01 5.81 E-01 5.95E-01 9106-0003-005F 2.101E-01 1.36E-01 1.56E-01 1.93E-01 9106-0003-006F 1.05E-01 1.86E-02 4.55E-02 8.27E-02 9106-0003-007F 2.64E-02 2.90E-02 2.74E-02 6.47E-02 9106-0003-008F 2.46E-01 1.09E-01 1.50E-01 2.41E-01 9106-0003-009F 3.18E-0 I 4.45E-01 3.93E-01 4.3 1E-01 9106-0003-01 OF 2.04E-01 2.28E-01 2.15E-01 2.52E-01 9106-0003-012F 4.27E-02 1.45E-02 2.31 E-02 6.03E-02 9106-0003-013F 1.96E-02 2.41 E-02 2.21 E-02 5.93E-02 9106-0003-014F 2.91 E-0I 4.33E-01 3.77E-01 4.09E-01 9106-0003-015F 2.57E-01 8.05E-01 6.11 E-01 6.22E-01 9106-0003-016F 3.52E-04 2.02E-02 1.34E-02 5.06E-02 9106-0003-018F 1.90E-01 1.85E-01 1.82E-01 2.19E-01 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60;these are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE (2) This column is the sum of the DCGL unity fraction from identified radionuclides of concern and HTD isotope (Pu-241) exceeding the 5%/10% rule for one or more FSS samples. For those samples not measured for HTD isotopes, an average calculated value of 6.1% of the DCGL was added to each sample.The sample location designations of Table 5 are not sequentially inclusive because of the necessity to relocate some samples due to the accessibility of the original sample locations.

Sample number 9106-0003-01 IF could not be sampled due to an obstruction.

Therefore sample number 9106-0003-018F was added as a replacement sample. Sample number 9106-0003-017F was a biased sample location; not part of the non-parametric design.The off-site laboratory also processed four (4) samples for HTD analysis as required by the sample plan. The requested analyses included alpha Revision 0 12 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC. Four (4) of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one (1) sample. Each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules, except for Pu-241. These results are presented in Table 6.<pC/g' I 1Qprational DCG L 9106-0003-004F 8.31 0.014 9106-0003-008F 54.2 0.092 9106-0003-014F 19.0 0.032 9106-0003-015F 6.63 0.011 (1) The Operational DCGL from Table 2 is 592 pCi/g for Pu-241.One (1) biased sample was collected at a location selected by FSS Supervision based on professional judgment and observation.

Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC. The sample was at 0.8% of the Operational DCGL. No further action or investigations were required (see Table 7).STable 7 -Biased Sample Results"'..s-.. Co-60 Fraction of mSample Number O -g operational p~i/g> ~ ~ilgDCGLP 9106-0003-017F 0.OOE+00 2.08E-02 0.008 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 and are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE 7. QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis.

Two (2) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey. " There was acceptable agreement between the field split results for both of the "split sample" pairs tested.The sample analysis vendor, General Engineering Laboratories (GEL) -Charleston, South Carolina, maintained quality control and quality assurance plans as part of normal operation.

Refer to Attachment 2 for data and data quality analysis results.Revision 0 13 Revision 0 13 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD 8. INVESTIGATIONS AND RESULTS Sample investigation levels were not exceeded for this unit, consequently none were performed.

9. REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.10. CHANGES FROM THE FINAL STATUS SURVEY PLAN The survey was designed to ten (10) mrem/yr TEDE which was conservative and necessary at the time of FSS planning.

It is no longer required as the total dose from existing and future groundwater has been established.

The dose for soil used to demonstrate compliance with the LTP and CTDEP criteria is seventeen (17) mrem/yr TEDE as discussed in Section 2 of this Release Record.11. DATA QUALITY ASSESSMENT (DQA)The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment. " The sample design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs.The evaluation of the Sign Test results indicates that the survey unit passes the unrestricted release criterion, thus, the null hypothesis is rejected.Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation).

The standard deviation of the sample results was below the design value used. This is represented by a favorable shift in the retrospective power curve as shown in Attachment 2f. This would indicate the retrospective power exceeds the prospective power, indicating that the design sample population was adequate.

The mean and median values are well below the Operational DCGL when used in conjunction with the unity rule.Therefore, the survey unit meets the unrestricted release criterion with adequate power as required by the DQOs.Revision 0 14 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD The range of the data, about 2.98 standard deviations, was not unusually large.The difference between the mean and median was 5.5% of the standard deviation which indicates limited skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows some positive skewness as confirmed by the calculated skew of 1.2.All data, assessments, and graphical representations are provided in Attachment 2.12. ANOMALIES An anomaly was encountered at one non-parametric sample location which could not be sampled due to an obstruction.

The sample (9106-0003-01 IF) was replaced with another randomly generated location (9106-0003-018F).

This is noted in the field notes and other documentation associated with this survey unit.In addition, one HTD radionuclide was reported in concentrations exceeding the 5% and 10% rule for de-selection.

Therefore, the individual Operational DCGLs for Pu-239 was included into sample analyses in conjunction with the unity rule to ensure adequate survey design in accordance with the DQOs. The result of the COMPASS computer run showed adequate power and maintained the original sixteen (16) sediment samples for non-parametric statistical testing.13. CONCLUSION Survey Unit 9106-0003 has met the final DQOs of the FSS. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved.

Elevated Measurement Comparison and remediation was not required.The sample data passed the Sign Test. The null hypothesis was rejected.Graphical representation of data indicates some positive skewness that is probably due to the differences in terrain and the collection of runoff. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved.

The survey unit was properly designated as Class 2.The dose contribution from soil is 4.3 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.This survey unit is affected by existing groundwater (reference CY memo ISC 06-024). Therefore, the dose contribution from existing groundwater is two (2) mrem/yr TEDE.This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component, is therefore 0 mrem/yr TEDE.Revision 0 15 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 6.3 mrem/yr Total Effective Dose Equivalent (TEDE).14. ATTACHMENTS 14.1 Attachment 1 -Figures 14.2 Attachment 2 -Sample and Statistical Data Revision 0 16 Revision 0 16 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD Attachment 1 Figures (5 pages)

A 141 Connecticut Yankee Atomic Power Company1 Site Map With Reference To Survey Unit 9106-0003 Sample Loation 9 qf Pond 5 1 18 4 0 30 60 Feet 3 Connecticut Yankee Atomic Power Company 9106-0003 Final Status Survey Sample Locations 0.318& n Note.Clmdum-137 zesidts aw given inpCilg.0.19 6'W Pond 0 30 60 ,i IFeet 9106-0003 Final Status Survey Cesium-13 7 Posting Plot Sample Location NOTE.-Cobalt-60 raguk, are given in pcilg 0.445 0.136 9 000.185'l Pond 0.743 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD Attachment 2a Sample Data (186 Pages)

Table of Contents G eneral Narrative

..................................................................

1 Chain of Custody and Supporting Documentation

...........

4 Radiological Analysis ..........................................................

I Sample Data Summary ......................................................

22 Q uality C ontrol D ata ...........................................................

64 General Narrative 1 CASE NARRATIVE For CONNECTICUT YANKEE RE: Sediment PO# 002332 Work Order: 162335 SDG: MSR #06-0652 June 2, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shippin2 Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on May 5, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 162335001 9106-0003-001F 162335002 9106-0003-002F 162335003 9106-0003-003F 162335004 9106-0003-004F 162335005 9106-0003-004FS 162335006 9106-0003-005F 162335007 9106-0003-006F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712 -Charleston, SC 29417

  • 2040 Savage Road (29407)Phone (843) 556-8171 -Fat(843) 766-1178
  • www.gel.com Sample ID 162335008 162335009 162335010 162335011 162335012 162335013 162335014 162335015 162335016 162335017 162335018 162335019 Client Sample ID 9106-0003-007F 9106-0003-009F 9106-0003-OIOF 9106-0003-O1OFS 9106-0003-012F 9106-0003-013F 9106-0003-015F 9106-0003-016F 9106-0003-017F 9106-0003-018F 9106-0003-008F 9106-0003-014F Items of Note: There are no items of note.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Seventeen sediment samples were analyzed for FSSGAM.Two sediment samples were analyzed for FSSALL.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)Phone (843) 556-8171 ° Fax (843) 766-1178 .www.gel.com 3

Chain of Custody and Supporting Documentation 4

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 1 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 Project Name: Haddam Neck Decommissic Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

Z 30 D. E] 14 D. n] 7 D.Comment .. P " -vation Comment, Preservation Samples Shipped Via: Z Fed Ex LI uPs n] Hand 1) Relinquished By 3) Relinquished By C1 Other Bill of Lading #7-t12O-%?,a-0261 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00312 362 Injun Hollow Road, East Hampton, CT 06424 .2 ! .f V 860-267-2556 ,u#--.-,.--.u I(9 3 'Project Name: ]Haddam Neck Decommissioning Analyses Requested

ýL'ý" Use Oly"'Contact Name & Phone: Cmmient:,.

Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State) ,1 General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Co V V)Priority:

[ 30 D. LI 14 D. EJ 7 D. Container Sample Size- J Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation

¢lab S p 9106-0003-OO1F 4/24/06 14:13 SE C BP X Transferred from COC2006-00221

.7 .9106-0003-002F 4/24/06 14:39 SE C BP X Transferred from COC2006-00221 ci! 9106-0003-003F 4/24/06 15:01 SE C BP X Transferred from COC2006-00221 9106-0003-004F 4/25/06 08:41 SE C BP X Transferred from COC2006-00223

, 9106-0003-004FS 4/25/06 08:41 SE C BP X Transferred from COC2006-00223

, 9106-0003-005F 4/25/06 09:21 SE C BP X Transferred from COC2006-00223

,.9106-0003-006F 4/25/06 09:46 SE C BP X Transferred from COC2006-00223

.> ./t 9106-0003-007F 4/25/06 10:28 SE C BP X Transferred from COC2006-00223 9106-0003-008F 4/25/06 11:15 SE C BP X Transferred from COC2006-00223 NOTES: PO #: 002332 MSR #: 0 6-° ¢ SSWP# NA Z LTP QA El Radwaste QA El Non QA Samples Shipped Via: :ptanal Con'tainer:

Combined samples 9106-0003-003F taken on 4/25/06 @08:19 and 9106-0003-003FB taken on 4/25/06 @ 08:19 in order to have sufficient sample for counting.

Z Fed Ex iTemp.*, .Deg, C-LI u: < s El UPS ...," l,7.,,.-:, ElHand Cus d~y' Sealed?___ __ __ __ ___ __ __ __Y-0-1 NE t 1) Relinquished By Date/Time

2) ec ived By Date Time Custo'dy S1 Intact?S- /13.10 , d n 6 Other , 3) Relinquished By Date/Time
4) Received By Date/Time

__.______________

Bill of Lading #-5) Relinquished By Date/Time

6) Received By Date/Time

.0 0- J/?;0O- 0 2 40 .< ....

Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001

/ Figure 1. Sample Check-in List.Date/Time Received:

iEA 10(, 9 SDG#: M~~ 6,K 0 &2 Work Order Number: .(D'Z3 3 b7 Shipping Ccntainer ID:. "lcllW ' ) - I Chain of Custody# Q ( Y.00" 31 9", '

9 OO L(p -oo31 1. Custody Seals. ori shipping container intact? *Yes t j No 2. Custody Seals dated and signed? Yesj[ No 3. Chain-of-Custody record present? Yes No [ ]4. Cooler temperature

.c9 ,\5. Vermiculite/packing materials is: Wet [I Dry ]') fn Fr 6.' Number of samples in shipping container:

[ io3,e n Eq I rh71" n el.7. Sample holding times exceeded?

Yes [ No 10. Were any anomalies identified in sample receipt? Yes ' ] No*1. .Description of anomalies (include sample numbers): Sample Custodian/Laboratory:

.(2 Irv; (4 C'M Dat:. -)Telephoned to: On By .7 SAMPLE RECEIPT & REVIEW FORM IF PMuse only I (a2 33 IClient: '4 SDG/ARCOC/Work Order: Date Received:

reN ' 5 6 40 PM(A) Review (ensure non-counftorM ng items are resolved prior to signing): Received By: 6l QL4 ____________________

Sample Receipt Criteria Comments/Qualifiers (Required for Non-Conforming Items)1 Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (describe) and sealed?Samples requiring cold Circle Coolant # ice bags blue ice dry ice none 2 preservation within (4 +/- 2 C)?Record preservation method. /" Per r)L-t5 Chain of custody documents included with shipment?4 Sample containers intact and Circle Applicable:

seals broken damaged container leaking container other (describe) sealed?5 Samples requiring chemical Sample ID's, containers affected and observed pH: preservation at proper pH?6 VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory) 8 Samples received within holding Id'S and tests affected: time?9 Sample ID's on COC match ID's Sample ID's and containers affected: on bottles?10IDate & time on COC match date Sample ID's affected:& time on bottles?1Number of containers received Sample ID's affected: match number indicated on COC?COC form is properly signed in 12 relinquished/received sections?-"Air Bill ,Tracking

  1. 's, & to d. I Additional Comments "z--. ,.* " RSO RAD Receipt #Sr G~ *If > x2 area background is observed on samples identified as "non-Spt z regulated/non-radioactive", contact the Radiation Safety group for further_ __ investigation.

A Radiological Classification?7.

Maximum Counts Observed*:

t) 6P ju B PCB Regulated?

Comments: Shipped as DOT1 Hazardous C Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. I UN#: PM (or PMA) review of Hazard classification:

Initials /._, _- Date: 8 (./r r RADIOLOGICAL ANALYSIS 1 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 162335 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: Prep Method: DOE EML HASL-300, Am-05-RC Modified Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 530940 527706 527705 Sample ID 162335018 162335019 1201095113 1201095114 1201095115 1201095116 Client ID 9106-0003-008F 9106-0003-014F Method Blank (MB)162335018(9106-0003-008F)

Sample Duplicate (DUP)162335018(9106-0003-008F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

2 Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162335018 (9106-0003-008F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 3

Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: Prep Method: DOE EML HASL-300, Pu- 11-RC Modified Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 530942 527706 527705 Sample ID 162335018 162335019 1201095121 1201095122 1201095123 1201095124 Client ID 9106-0003-008F 9106-0003-014F Method Blank (MB)162335018(9106-0003-008F)

Sample Duplicate (DUP)162335018(9106-0003-008F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 I REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162335018 (9106-0003-008F).

QC Information All of the QC samples met the required acceptance limits.4 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS DOE EML HASL-300, Pu- 11-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 530943 527706 527705 5 Sample ID Client ID 162335018 9106-0003-008F 162335019 9106-0003-014F 1201095125 Method Blank (MB)1201095126 162335018(9106-0003-008F)

Sample Duplicate (DUP)1201095127 162335018(9106-0003-008F)

Matrix Spike (MS)1201095128 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162335018 (9106-0003-008F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 6 referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Analytical Method: Prep Method: Analytical Batch Number: Prep Batch Number: Gamma,Solid-FSS GAM & ALL FSS EML HASL 300, 4.5.2.3 Dry Soil Prep 528196 527705 7 Sample ID 162335001 162335002 162335003 162335004 162335005 162335006 162335007 162335008 162335009 162335010 162335011 162335012 162335013 162335014 162335015 162335016 162335017 162335018 162335019 1201088599 1201088600 1201088601 Client ID 9106-0003-001F 9106-0003-002F 9106-0003-003F 9106-0003-004F 9106-0003-004FS 9106-0003-005F 9106-0003-006F 9106-0003-007F 9106-0003-009F 9106-0003-OIOF 9106-0003-01OFS 9106-0003-012F 9106-0003-013F 9106-0003-015F 9106-0003-016F 9106-0003-017F 9106-0003-018F 9106-0003-008F 9106-0003-014F Method Blank (MB)162335001(9106-0003-00 IF) Sample Duplicate (DUP)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162335001 (9106-0003-001F).

QC Information 8

All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information 9

Qualifier UI Reason Data rejected due to high Full-Width Half-Maximum.

Data rejected due to interference.

Data rejected due to low abundance.

Analyte Sample UI UI Bismuth-214 Cesium- 137 Manganese-54 Europium-155 Cesium- 134 Cobalt-60 Radium-226 1201088599 162335016 162335019 162335018 162335002 162335003 162335004 162335006 162335007 162335009 162335010 162335011 162335012 162335015 162335016 162335019 162335011 1201088599 Method/Analysis Information Product: Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: GFPC, Sr90, solid-ALL FSS EPA 905.0 Modified Ash Soil Prep Dry Soil Prep 535512 527706 527705 10 Sample ID Client ID 162335018 9106-0003-008F 162335019 9106-0003-014F 1201105909 Method Blank (MB)1201105910 162335018(9106-0003-008F)

Sample Duplicate (DUP)1201105911 162335018(9106-0003-008F)

Matrix Spike (MS)1201105912 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162335018 (9106-0003-008F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.11 Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS DOE EML HASL-300, Tc-02-RC Modified Analytical Method: Analytical Batch Number: 531704 Sample ID 162335018 162335019 1201096867 1201096868 1201096869 1201096870 Client ID 9106-0003-008F 9106-0003-014F Method Blank (MB)162583001(NOL-02-02-005-F-S)

Sample Duplicate (DUP)162583001(NOL-02-02-005-F-S)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

12 Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162583001 (NOL-02-02-005-F-S).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 162335018 (9106-0003-008F) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 535483 Prep Batch Number: 527706 Dry Soil Prep GL-RAD-A-021 Batch Number: 527705 13 Sample ID Client ID 162335018 9106-0003-008F 162335019 9106-0003-014F 1201105872 Method Blank (MB)1201105873 162335018(9106-0003-008F)

Sample Duplicate (DUP)1201105874 162335018(9106-0003-008F)

Matrix Spike (MS)1201105875 Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162335018 (9106-0003-008F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples were reprepped due to low/high carrier/tracer yield.14 Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 527978 527706 527705 Sample ID 162335018 162335019 1201088147 1201088148 1201088149 1201088150 Client ID 9106-0003-008F 9106-0003-014F Method Blank (MB)162335018(9106-0003-008F)

Sample Duplicate (DUP)162335018(9106-0003-008F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.15 Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162335018 (9106-0003-008F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

The following NCR was generated for this SDG: NCR 321720 was generated due to Container scanning event for custody missed. 1. The analyst did not scan the samples 162335018 and 162335019 into the batch prior to analysis, however the samples did remain in their custody at all times. The error has been corrected and the analyst has been instructed on the proper scanning procedures.

1. Reporting results.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information 16 Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Analytical Batch Number: 531705 Sample ID 162335018 162335019 1201096877 1201096878 1201096879 1201096880 Client ID 9106-0003-008F 9106-0003-014F Method Blank (MB)162583001(NOL-02-02-005-F-S)

Sample Duplicate (DUP)162583001(NOL-02-02-005-F-S)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 11.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162583001 (NOL-02-02-005-F-S).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.17 Sample Re-prep/Re-analysis Sample 1201096877 (MB) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: Analytical Batch Number: Sample ID 162335018 162335019 1201104384 1201104385 1201104386 1201104387 EPA EERF C-01 Modified 534837 Client ID 9106-0003-008F 9106-0003-014F Method Blank (MB)162335019(9106-0003-014F)

Sample Duplicate (DUP)162335019(9106-0003-014F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).18 Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 162335019 (9106-0003-014F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Samples 1201104385 (9106-0003-014F), 162335018 (9106-0003-008F) and 162335019 (9106-0003-014F) were recounted due to high MDAs. Samples were reprepped due to low/high recovery.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the 19 data package.The following data validator verified the information presented in this case narrative:

Reviewer/Date:

(- V,ý'46 20 General Engineering Laboratories Form GEL-NCR Rev. 06/05 NCR Report No.: 321720 Revision No.: COMPANY -WIDE NONCONFORMANCE REPORT Mo.Day Yr. Division:

Quality Criteria:

Type: 01-JUN-06 Radiochemistry Specifications Process Instrument Type: Test I Method: Matrix Type: Client Code: BIOASSAY LSC DOE RESL Ni-1, Modified Solid YANK Batch ID: Sample Numbers: 527978 See Below Potentially affected work order(s)(SDG):

162335(MSR#06-0652)

Application Issues: Container scanning event for custody missed Specification and Requirements NRG Disposition:

Nonconformance

==

Description:==

1. The analyst did not scan the samples 162335018 and 162335019 into 1. Reporting results.the batch prior to analysis, however the samples did remain in their custody at all times. The error has been corrected and the analyst has been instructed on the proper scanning procedures.

Originator's Name: Melanie Aycock Quality Review: Data Validator/Group Leader: Heather Anderson 08-JUN-06 01-JUN-06 Director: Page 1 21 SAMPLE DATA

SUMMARY

22 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: MSR#06-0652 GEL Work Order: 162335 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the reporting limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by 23 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-001F 162335001 Soil 24-APR-06 05-MAY-06 Client 15.7%Proiect: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 0.640 0.00555 0.351 0.462 0.00674 0.128 0.107 0.00641-0.015 0.0713 0.670 0.562-0.0119 0.0123 10.9 0.462 0.0049 0.229+/-0.149+/-0.0707+/-0.281+/-0.0847+/-0.0184+/-0.0361+/-0.0311+/-0.043+1-0.0505+/-0.0618+/-0.0714+/-0.0771+/-0.0207+1-0.0151+/-0.996+/-0.0847+/-0.0138+/-0.0399 0.0501 0.0612 0.0993 0.0266 0.0164 0.0135 0.0144 0.0342 0.0422 0.0381 0.0212 0.0248 0.0145 0.0139 0.131 0.0266 0.0123 0.0131+/-0.149+/-0.0707+/-0.281+/-0.0847+/-0.0184+/-0.0361+/-0.0311+/-0.043+/-0.0505+/-0.0618+/-0.0714+/-0.0771+/-0.0207+1-0.0151+/-0.996+/-0.0847+/-0.0138+/-0.0399 0.106 0.126 0.211 0.0557 0.0346 0.0285 0.0312 0.0713 0.0909 0.0785 0.0439 0.0517 0.0307 0.0292 0.285 0.0557 0.0258 0.0277 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 05/31/06 1021 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 24 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-00IF 162335001 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.25 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company : Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result 9106-0003-002F 162335002 Soil 24-APR-06 05-MAY-06 Client 24.9%Project: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.816 Americium-241 U -0.00658 Bismuth-212 0.668 Bismuth-214 0.737 Cesium-134 UUI 0.00 Cesium-137 0.0437 Cobalt-60 U 0.0189 Europium-152 U -0.03 Europium-154 U -0.0149 Europium-155 U 0.0749 Lead-212 1.06 Lead-214 0.789 Manganese-54 U -0.0111 Niobium-94 U 0.0103 Potassium-40 12.5 Radium-226 0.737 Silver-108m U 0.00613 Thallium-208 0.340 Uncertainty

+/-0.163+/-0.123+/-0.340+/-0.107+/-0.0349+/-0.0291+/-0.0258+/-0.0655+/-0.0654+/-0.080+/-0.0751+/-0.0858+/-0.0254+/-0.0214+/-0.989+/-0.107+/-0.0206+/-0.0571 LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.0714 0.0837 0.141 0.0333 0.0284 0.0186 0.0235 0.0538 0.0546 0.0496 0.0297 0.0373 0.0206 0.0189 0.148 0.0333 0.0174 0.0182+/-0.163+/-0.123+/-0.340+/-0.107+/-0.0349+/-0.0291+/-0.0258+/-0.0655+/-0.0654+/-0.080+/-0.0751+/-0.0858+/-0.0254+/-0.0214+/-0.989+/-0.107+/-0.0206+/-0.0571 0.153 0.172 0.302 0.0707 0.0597 0.0396 0.0509 0.112 0.120 0.102 0.0615 0.0779 0.0439 0.0399 0.334 0.0707 0.0366 0.0387 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 05/31/06 1021 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows: LXM2 05/07/06 1536 527705*A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported 26 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Certificateof Analvsis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-002F 162335002 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.27 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-003F 162335003 Soil 24-APR-06 05-MAY-06 Client 12.6%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANKOO 1 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.691 Americium-241 U 0.0567 Bismuth-212 0.546 Bismuth-214 0.557 Cesium-134 UUI 0.00 Cesium-137 0.0393 Cobalt-60 U 0.0245 Europium-152 U 0.0141 Europium-154 U -0.0796 Europium-155 U 0.0703 Lead-212 0.715 Lead-214 0.693 Manganese-54 U 0.00312 Niobium-94 U -0.00416 Potassium-40 9.93 Radium-226 0.557 Silver-108m U -0.0208 Thallium-208 0.197+/-0.118+/-0.087+/-0.249+/-0.0675+/-0.027+/-0.0252+/-0.0188+/-0.0403+/-0.0517+/-0.0578+/-0.0498+/-0.0729+/-0.0175+/-0.0165+/-0.658+/-0.0675+/-0.015+/-0.037 0.0423 0.0631 0.102 0.0257 0.0184 0.0139 0.018 0.0369 0.0374 0.0397 0.0219 0.0281 0.0153 0.0123 0.110 0.0257 0.0121 0.0139+/-0.118+/-0.087+/-0.249+/-0.0675+/-0.027+/-0.0252+/-0.0188+/-0.0403+/-0.0517+/-0.0578+/-0.0498+/-0.0729+/-0.0175+/-0.0165+/-0.658+/-0.0675+/-0.015+/-0.037 0.0912 0.130 0.218 0.0542 0.0387 0.0293 0.0385 0.0769 0.0818 0.0816 0.0453 0.0583 0.0323 0.026 0.246 0.0542 0.0253 0.0293 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 05/31/06 1022 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 28 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-003F Project: YANK01204 Sample ID: 162335003 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.29 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificatie of Annlvqi, Company: Connecticut Yankee Atomic Power Address: 362 lnjun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-004F 162335004 Soil 25-APR-06 05-MAY-06 Client 20.9%Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.743 Americium-241 U 0.080 Bismuth-212 0.561 Bismuth-214 0.467 Cesium-134 UUI 0.00 Cesium-137 0.292 Cobalt-60 0.743 Europium-152 U -0.0383 Europium-154 U 0.0175 Europium-155 U 0.0679 Lead-212 0.744 Lead-214 0.632 Manganese-54 U -0.00494 Niobium-94 U 0.0149 Potassium-40 10.5 Radium-226 0.467 Silver-108m U -0.0156 Thallium-208 0.239+/-0.177+/-0.0848+/-0.246+/-0.0843+/-0.0421+/-0.050+/-0.0722+/-0.0535+/-0.0552+/-0.050+/-0.0622+/-0.0994+/-0.0237+/-0.019+/-0.878+/-0.0843+/-0.0165+/-0.0385 0.0741 0.0694 0.143 0.0338 0.0235 0.0179 0.0177 0.0426 0.0481 0.0475 0.0253 0.0331 0.0193 0.0178 0.149 0.0338 0.0137 0.0155+/-0.177+/-0.0848+/-0.246+/-0.0843+/-0.0421+/-0.050+/-0.0722+/-0.0535+/-0.0552+1-0.050+/-0.0622+/-0.0994+/-0.0237+/-0.019+/-0.878+/-0.0843+/-0.0165+/-0.0385 0.157 0.143 0.303 0.0712 0.0495 0.0379 0.0386 0.0893 0.105 0.098 0.0525 0.069 0.0409 0.0374 0.332 0.0712 0.0288 0.0329 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 05/31/06 1022 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 30 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-004F 162335004 Project: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.31 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-004FS 162335005 Soil 25-APR-06 05-MAY-06 Client 24.4%Project: YANK01204 Client ID: YANKOO0 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-ESS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 U Bismuth-214 Cesium-134 U Cesium-137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U Thallium-208 0.904-0.0871 0.233 0.577 0.0183 0.314 0.984-0.025-0.0144 0.0585 0.872 0.636-0.0163 0.0151 12.7 0.577 0.0178 0.271+/-0.210+/-0.147+/-0.344+/-0.095+/-0.0318+/-0.046+/-0.103+/-0.0537+/-0.0724+/-0.0663+/-0.0947+/-0.102+/-0.0262+/-0.0212+/-1.23+/-0.095+/-0.0154+/-0.0547 0.0771 0.0818 0.161 0.033 0.0242 0.0197 0.019 0.0467 0.0606 0.052 0.0264 0.0326 0.0211 0.0187 0.163 0.033 0.0166 0.0184+/-0.210+/-0.147+/-0.344+/-0.095+/-0.0318+/-0.046+/-0.103+/-0.0537+/-0.0724+/-0.0663+/-0.0947+/-0.102+/-0.0262+/-0.0212+/-1.23+/-0.095+/-0.0154+/-0.0547 0.162 0.167 0.336 0.069 0.0505 0.0412 0.0409 0.0968 0.129 0.106 0.0544 0.0677 0.0443 0.039 0.356 0.069 0.0345 0.0384 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 05/31/06 1023 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 32 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-004FS 162335005 Proiect: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.33 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analyvis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-005F 162335006 Soil 25-APR-06 05-MAY-06 Client 19.4%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 UUI Cesium- 137 Cobalt-60 Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 0.810 0.0234 0.648 0.637 0.00 0.210 0.136-0.0439-0.0179 0.0147 0.757 0.714 0.00687-0.0014 11.2 0.637-0.00275 0.273+/-0.183+/-0.036+/-0.358+/-0.112+/-0.0379+/-0.0415+/-0.0507+/-0.0596+/-0.0729+/-0.0557+/-0.0591+/-0.0897+/-0.026+/-0.0222+/-0.854+/-0.112+/-0.0221+/-0.0491 0.0752 0.0312 0.164 0.0383 0.0262 0.0214 0.0187 0.0513 0.0616 0.051 0.0304 0.038 0.0227 0.0194 0.194 0.0383 0.0191 0.0204+/-0.183+/-0.036+/-0.358+/-0.112+/-0.0379+/-0.0415+/-0.0507+/-0.0596+/-0.0729+/-0.0557+/-0.0591+/-0.0897+/-0.026+/-0.0222+/-0.854+/-0.112+/-0.0221+/-0.0491 0.159 0.0638 0.344 0.080 0.0547 0.0447 0.0404 0.106 0.131 0.105 0.0627 0.0788 0.0476 0.0406 0.418 0.080 0.0397 0.0427 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 05/31/06 1023 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 34 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-005F 162335006 Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.35 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-006F 162335007 Soil 25-APR-06 05-MAY-06 Client 27.9%Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAAM & ALL FSS Actinium-228 0.808 Americium-241 U -0.0509 Bismuth-212 0.562 Bismuth-214 0.562 Cesium-134 UUI 0.00 Cesium-137 0.105 Cobalt-60 U 0.0186 Europium-152 U -0.0255 Europium-154 U 0.0125 Europium-155 U 0.0834 Lead-212 0.894 Lead-214 0.686 Manganese-54 U 0.0168 Niobium-94 U -0.00862 Potassium-40 14.6 Radium-226 0.562 Silver-108m U 0.00453 Thallium-208 0.285+/-0.189+/-0.111+/-0.324+/-0.106+/-0.0388+/-0.0477+/-0.0229+/-0.0547+/-0.068+/-0.0936+/-0.0948+/-0.102+/-0.0254+/-0.0187+/-1.33+/-0.106+/-0.0169+/-0.0542 0.0619 0.0797 0.130 0.0306 0.0232 0.0187 0.0204 0.043 0.0575 0.0445 0.0256 0.0313 0.0173 0.0149 0.110 0.0306 0.0146 0.0162+/-0.189+/-0.111+/-0.324+/-0.106+/-0.0388+/-0.0477+/-0.0229+/-0.0547+/-0.068+/-0.0936+/-0.0948+/-0.102+/-0.0254+/-0.0187+/-1.33+/-0.106+/-0.0169+/-0.0542 0.132 0.164 0.276 0.0645 0.0487 0.0393 0.0441 0.0896 0.124 0.0917 0.0529 0.0652 0.0367 0.0315 0.252 0.0645 0.0307 0.0342 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 05/31/06 1112 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 36 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-006F 162335007 Proiect: Client ID: Vol. Recv.: YANKO 1204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier* QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.37 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -vww.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result 9106-0003-007F 162335008 Soil 25-APR-06 05-MAY-06 Client 10.9%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.517 Americium-241 U 0.000336 Bismuth-212 0.382 Bismuth-214 0.481 Cesium-134 U 0.0215 Cesium-137 U 0.0264 Cobalt-60 U 0.029 Europium-152 U 0.0144 Europium-154 U 0.0132 Europium-155 U 0.0317 Lead-212 0.628 Lead-214 0.510 Manganese-54 U -0.00489 Niobium-94 U 0.00332 Potassium-40 9.43 Radium-226 0.481 Silver-108m U 0.000625 Thallium-208 0.176 Uncertainty

+/-0.112+/-0.0951+/-0.238+/-0.0661+/-0.0213+/-0.0204+/-0.0355+/-0.0384+/-0.0495+/-0.0496+/-0.0457+/-0.0692+/-0.0168+/-0.0141+/-0.672+/-0.0661+/-0.0127+/-0.0378 LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.0452 0.0786 0.090 0.025 0.018 0.0141 0.0161 0.034 0.0434 0.0411 0.0187 0.0242 0.0139 0.0124 0.129 0.025 0.0115 0.0115+/-0.112+/-0.0951+/-0.238+/-0.0661+/-0.0213+/-0.0204+/-0.0355+/-0.0384+/-0.0495+/-0.0496+/-0.0457+/-0.0692+/-0.0168+/-0.0141+/-0.672+/-0.0661+/-0.0127+/-0.0378 0.0971 0.163 0.193 0.0528 0.038 0.0298 0.0347 0.0712 0.0938 0.0848 0.039 0.0508 0.0296 0.0262 0.283 0.0528 0.0243 0.0246 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 05/31/06 1149 528196 1 The following Prep Methods were performed Method Description Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description Analyst Date Time Prep Batch LXM2 05/07/06 1536 527705 I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria* Result is less than value reported> Result is greater than value reported 38 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-007F 162335008 Proiect: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.39 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 91 06-0003-009F 162335009 Soil 25-APR-06 05-MAY-06 Client 17.9%Project: Client ID: Vol. Recv.: YANK01204 YANKOO Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS Actinium-228 0.719 Americium-241 U 0.0062 Bismuth-212 U 0.229 Bismuth-214 0.434 Cesium-134 UUI 0.00 Cesium-137 0.318 Cobalt-60 0.445 Europium-152 U 0.013 Europium-154 U 0.0143 Europium-155 U 0.0386 Lead-212 0.666 Lead-214 0.507 Manganese-54 U -0.0112 Niobium-94 U -0.00588 Potassium-40 10.9 Radium-226 0.434 Silver-108m U -0.00469 Thallium-208 0.196+/-0.154+/-0.0182+/-0.253+/-0.0714+/-0.0227+/-0.0367+/-0.0475+/-0.0375+/-0.054+/-0.0411+/-0.0419+/-0.0629+/-0.0181+/-0.0152+/-0.688+/-0.0714+/-0.0128+/-0.0361 0.0493 0.0173 0.114 0.0244 0.0193 0.0145 0.0139 0.0335 0.0469 0.0284 0.0209 0.0244 0.0146 0.0128 0.133 0.0244 0.0115 0.0123+/-0.154+/-0.0182+/-0.253+/-0.0714+/-0.0227+/-0.0367+/-0.0475+/-0.0375+/-0.054+/-0.0411+/-0.0419+/-0.0629+/-0.0181+/-0.0152+/-0.688+/-0.0714+/-0.0128+/-0.0361 0.105 0.0355 0.239 0.0515 0.0405 0.0305 0.0303 0.0697 0.100 0.0585 0.0431 0.0508 0.031 0.0269 0.291 0.0515 0.0241 0.026 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 05/31/06 1150 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 40 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-009F Proiect: YANK01204 Sample ID: 162335009 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.41 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-01OF 162335010 Soil 25-APR-06 05-MAY-06 Client 15.8%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.848 Americium-241 U -0.00399 Bismuth-212 0.626 Bismuth-214 0.658 Cesium-134 UUI 0.00 Cesium-137 0.204 Cobalt-60 0.228 Europium-152 U 0.0348 Europium-154 U 0.032 Europium-155 U 0.0754 Lead-212 0.881 Lead-214 0.840 Manganese-54 U -0.00224 Niobium-94 U 0.00778 Potassium-40 12.4 Radium-226 0.658 Silver-108m U 0.00435 Thallium-208 0.267+/-0.169+/-0.0658+/-0.223+/-0.0977+/-0.0242+1-0.0415+/-0.0508+1-0.0545+/-0.058+/-0.0616+/-0.0859+/-0.100+/-0.0189+/-0.0157+/-1.01+/-0.0977+/-0.0158+/-0.0454 0.0514 0.0526 0.110 0.0271 0.0187 0.0166 0.0151 0.0416 0.0511 0.043 0.0248 0.029 0.0164 0.0143 0.102 0.0271 0.0141 0.015+/-0.169+/-0.0658+/-0.223+/-0.0977+/-0.0242+/-0.0415+/-0.0508+1-0.0545+/-0.058+/-0.0616+/-0.0859+/-0.100+/-0.0189+/-0.0157+/-1.01+/-0.0977+/-0.0158+/-0.0454 0.103 0.105 0.219 0.0542 0.0374 0.0332 0.0302 0.0831 0.102 0.086 0.0497 0.058 0.0329 0.0286 0.203 0.0542 0.0282 0.030 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 05/31/06 1243 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 42 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-OIOF 162335010 Project: YANKO 1204 Client ID: YANKOOl Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.43 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: 9106-0003-010FS Project: YANKO 1204 Sample ID: 162335011 Client ID: YANKOOl Matrix: Soil Vol. Recv.: Collect Date: 25-APR-06 Receive Date: 05-MAY-06 Collector:

Client Moisture:

15.5%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 UUI Cesium-137 Cobalt-60 UUI Europium-152 U Europium-154 U Europium-155 U Lead-212 Lead-214 Manganese-54 U Niobium-94 U Potassium-40 Radium-226 Silver-108m U -Thallium-208 0.731-0.0861 0.464 0.736 0.00 0.169 0.00 0.00825-0.0128 0.0139 0.841 0.851-0.0134 0.0167 11.3 0.736-0.00529 0.266+/-0.148+/-0.0773+/-0.253+/-0.101+/-0.0312+/-0.0358+/-0.0404+/-0.0439+/-0.0532+/-0.0539+/-0.0842+/-0.102+/-0.020+/-0.0157+/-0.982+/-0.101+/-0.0156+/-0.0396 0.0534 0.0637 0.116 0.0282 0.0199 0.0153 0.0303 0.0397 0.0448 0.045 0.0226 0.0272 0.0165 0.0146 0.143 0.0282 0.0134 0.0142+/-0.148+/-0.0773+/-0.253+/-0.101+/-0.0312+/-0.0358+/-0.0404+/-0.0439+/-0.0532+/-0.0539+/-0.0842+/-0.102+/-0.020+/-0.0157+/-0.982+/-0.101+/-0.0156+/-0.0396 0.113 0.131 0.245 0.0589 0.0416 0.0321 0.063 0.0823 0.0961 0.0923 0.0467 0.0565 0.0348 0.0306 0.310 0.0589 0.028 0.0298 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 05/31/06 1722 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 44 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-010FS 162335011 Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.45 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Cs~rfri~ofe af A ns1hrece tt.t ttttt.tt, t~t flhIUR V OZ~Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-012F 162335012 Soil 25-APR-06 05-MAY-06 Client 10.5%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.944 Americium-241 U -0.108 Bismuth-212 0.686 Bismuth-214 0.573 Cesium-134 UUI 0.00 Cesium-137 0.0427 Cobalt-60 U 0.0145 Europium-152 U -0.00296 Europium-154 U -0.0379 Europium-155 U 0.0158 Lead-212 0.871 Lead-214 0.606 Manganese-54 U 0.0177 Niobium-94 U-0.000997 Potassium-40 10.3 Radium-226 0.573 Silver-108m U -0.00211 Thallium-208 0.287+/-0.128+/-0.105+/-0.178+/-0.0696+/-0.0249+/-0.0245+/-0.0186+/-0.0424+/-0.0639+/-0.0486+/-0.0541+/-0.0738+/-0.0179+/-0.0157+/-0.691+/-0.0696+/-0.0133+/-0.036 0.0471 0.0811 0.110 0.0259 0.0192 0.0126 0.017 0.0362 0.0431 0.0466 0.0223 0.0284 0.0163 0.0134 0.135 0.0259 0.0119 0.0127+/-0.128+1-0.105+/-0.178+/-0.0696+/-0.0249+/-0.0245+/-0.0186+/-0.0424+/-0.0639+/-0.0486+/-0.0541+/-0.0738+/-0.0179+/-0.0157+/-0.691+/-0.0696+/-0.0133+/-0.036 0.101 0.168 0.233 0.0546 0.0404 0.0269 0.0367 0.0757 0.0935 0.0958 0.0462 0.0592 0.0344 0.0283 0.298 0.0546 0.0251 0.027 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 05/31/06 1723 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 46 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-012F Project: YANKO1204 Sample ID: 162335012 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier* QC Samples were not spiked with this compound^ RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.47 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result 9106-0003-013F 162335013 Soil 25-APR-06 05-MAY-06 Client 35.4%Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Units DF Analyst Date Time Batch Mtd Parameter Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U Bismuth-212 Bismuth-214 Cesium-134 U Cesium-137 U 0.950-0.0155 0.769 0.689 0.0358 0.0196 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 U 0.0241 U -0.0728 U 0.0364 U 0.0211 1.22 0.763 U -0.00992 U 0.00629 19.6 0.689 U -0.019 0.339 Uncertainty

+/-0.267+/-0.124+/-0.384+/-0.128+/-0.0353+/-0.0262+/-0.0353+/-0.0763+/-0.0868+/-0.0691+/-0.0914+/-0.131+/-0.0283+/-0.0335+/-1.23+/-0.128+/-0.0249+/-0.0682 0.0693 0.0897 0.196 0.0464 0.0295 0.023 0.0265 0.0585 0.0759 0.0597 0.0359 0.0439 0.0226 0.0206 0.227 0.0464 0.0189 0.0232+/-0.267+/-0.124+/-0.384+/-0.128+/-0.0353+/-0.0262+/-0.0353+/-0.0763+/-0.0868+/-0.0691+/-0.0914+/-0.131+/-0.0283+/-0.0335+/- 1.23+/-0.128+/-0.0249+/-0.0682 0.150 0.185 0.414 0.0975 0.0622 0.0488 0.0573 0.122 0.164 0.123 0.0741 0.0915 0.0482 0.0436 0.499 0.0975 0.0397 0.0489 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g.pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LC TPU MDA MJHI 05/31/06 1724 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed LXM2 05/07/06 1536 527705 Method I Description EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 48 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-013F 162335013 Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.49 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Qualifier Result 9106-0003-015F 162335014 Soil 26-APR-06 05-MAY-06 Client 19.9%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS Actinium-228 0.682 Americium-241 U -0.0444 Bismuth-212 0.651 Bismuth-214 0.446 Cesium-134 U 0.0335 Cesium-137 0.257 Cobalt-60 0.805 Europium-152 U -0.0503 Europium-154 U 0.00444 Europium-155 U 0.0251 Lead-212 0.741 Lead-214 0.638 Manganese-54 U 0.00149 Niobium-94 U -0.00431 Potassium-40 11.3 Radium-226 0.446 Silver-108m U -0.00188 Thallium-208 0.246+/-0.213+/-0.0952+/-0.327+/-0.0833+/-0.0326+/-0.0479+/-0.0828+/-0.0545+/-0.0697+/-0.0558+/-0.0638+/-0.0878+/-0.0272+/-0.0214+/-0.805+/-0.0833+/-0.0197+/-0.0422 0.0694 0.076 0.143 0.0339 0.0241 0.0172 0.0204 0.0447 0.0591 0.0498 0.0269 0.0329 0.023 0.0181 0.141 0.0339 0.0165 0.020+/-0.213+/-0.0952+/-0.327+/-0.0833+/-0.0326+/-0.0479+/-0.0828+/-0.0545+/-0.0697+/-0.0558+/-0.0638+/-0.0878+/-0.0272+/-0.0214+/-0.805+/-0.0833+/-0.0197+/-0.0422 0.147 0.156 0.304 0.0714 0.0507 0.0365 0.0442 0.0934 0.127 0.102 0.0556 0.0687 0.0482 0.038 0.315 0.0714 0.0346 0.042 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 05/31/06 1724 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 50 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-015F 162335014 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UIl Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.51 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-016F 162335015 Soil 26-APR-06 05-MAY-06 Client 15.4%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actinium-228 0.485 Americium-241 U 0.0196 Bismuth-212 0.348 Bismuth-214 0.403 Cesium-134 UJUI 0.00 Cesium-137 U 0.000352 Cobalt-60 U 0.0202 Europium-152 U -0.0118 Europium-154 U 0.0276 Europium-t55 U 0.00266 Lead-212 0.488 Lead-214 0.390 Manganese-54 U 0.00955 Niobium-94 U 0.0164 Potassium-40 8.00 Radium-226 0.403 Silver-108m U 0.0079 Thallium-208 0.170+/-0.112+/-0.0623+/-0.142+/-0.0668+/-0.0237+/-0.0154+/-0.020+/-0.0424+/-0.060+/-0.037+/-0.0437+/-0.0686+1-0.015+/-0.0146+/-0.691+/-0.0668+/-0.0126+/-0.0404 0.0433 0.0518 0.115 0.0219 0.0173 0.0133 0.0142 0.0314 0.0374 0.0351 0.0199 0.0231 0.0134 0.0136 0.118 0.0219 0.0109 0.0119+/-0.112+/-0.0623+/-0.142+/-0.0668+/-0.0237+/-0.0154+/-0.020+/-0.0424+/-0.060+/-0.037+/-0.0437+/-0.0686+/-0.015+/-0.0146+/-0.691+/-0.0668+/-0.0126+/-0.0404 0.0936 0.107 0.243 0.0467 0.0367 0.0283 0.0312 0.0661 0.0822 0.0726 0.0414 0.0487 0.0287 0.0287 0.264 0.0467 0.023 0.0253 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 05/31/06 1725 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 52 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 lnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-016F Proiect: YANKO 1204 Sample ID: 162335015 Client ID: YANKOO I Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.53 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-017F 162335016 Soil 26-APR-06 05-MAY-06 Client 18.5%Proiect: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 1.25 Americium-241 U 0.0391 Bismuth-212 0.847 Bismuth-214 0.880 Cesium-134 UUI 0.00 Cesium-137 UUI 0.00 Cobalt-60 U 0.0208 Europium-152 U -0.0194 Europium-154 U 0.00332 Europium-155 U 0.069 Lead-212 1.24 Lead-214 1.02 Manganese-54 U 0.00696 Niobium-94 U 0.00448 Potassium-40 13.2 Radium-226 0.880 Silver-108m U -0.00197 Thallium-208 0.413+/-0.253+/-0.146+/-0.246+/-0.115+/-0.0443+/-0.0357+/-0.0239+/-0.053+/-0.0714+/-0.0628+/-0.122+/-0.130+/-0.0258+/-0.0306+/- 1.27+/-0.115+/-0.0175+/-0.0528 0.0616 0.0859 0.131 0.0333 0.0252 0.0203 0.0217 0.0462 0.0609 0.0529 0.0279 0.0335 0.0191 0.0178 0.163 0.0333 0.0152 0.0186+/-0.253+/-0.146+/-0.246+/-0.115+/-0.0443+/-0.0357+/-0.0239+/-0.053+/-0.0714+/-0.0628+/-0.122+/-0.130+/-0.0258+/-0.0306+/-1.27+/-0.115+/-0.0175+/-0.0528 0.131 0.176 0.277 0.0697 0.0525 0.0424 0.0464 0.0958 0.130 0.108 0.0573 0.0694 0.0404 0.0372 0.356 0.0697 0.0317 0.0389 pCi/g pCi/g.pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHl 05/31/06 1726 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 54 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-017F Project: YANKO 1204 Sample ID: 162335016 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier* QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.55 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-018F 162335017 Soil 26-APR-06 05-MAY-06 Client 19.6%Proiect: YANKO 1204 Client ID: YANKOO0 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.397 Americium-241 U 0.000262 Bismuth-212 U 0.309 Bismuth-214 0.360 Cesium-134 U 0.0232 Cesium-137 0.190 Cobalt-60 0.185 Europium-152 U -0.00454 Europium-154 U 0.0156 Europium-155 U 0.0431 Lead-212 0.516 Lead-214 0.420 Manganese-54 U6.390E-06 Niobium-94 U 0.00578 Potassium-40 9.25 Radium-226 0.360 Silver-108m U 0.0022 Thallium-208 0.133+/-0.164+/-0.0286+/-0.280+/-0.081+/-0.0253+/-0.0405+/-0.0516+/-0.0526+/-0.0628+/-0.0437+/-0.0495+/-0.0794+/-0.0235+/-0.0201+/-0.728+/-0.081+/-0.0189+/-0.0506 0.0734 0.0275 0.158 0.0367 0.0233 0.0196 0.0201 0.047 0.0554 0.0435 0.0279 0.035 0.0204 0.018 0.167 0.0367 0.0167 0.0203+/-0.164+/-0.0286+/-0.280+/-0.081+/-0.0253+/-0.0405+/-0.0516+/-0.0526+/-0.0628+/-0.0437+/-0.0495+/-0.0794+/-0.0235+/-0.0201+/-0.728+/-0.081+/-0.0189+/-0.0506 0.154 0.0564 0.330 0.0766 0.0487 0.0411 0.043 0.0976 0.118 0.0893 0.0574 0.0725 0.0429 0.0377 0.362 0.0766 0.0348 0.0424 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 05/31/06 1727 528196 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported 56 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-018F 162335017 Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value isestimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.57 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-008F 162335018 Soil 25-APR-06 05-MAY-06 Client 15%Proiect: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U Curium-242 U Curium-243/244 U Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -Plutonium-239/240 U -(Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS Actinium-228 Americium-241 U -(Bismuth-212 Bismuth-214 Cesium- 134 U Cesium-137 Cobalt-60 Europium-152 U (Europium-154 U Europium-155 UUI Lead-212 Lead-214 Manganese-54 U -(Niobium-94 U -(Potassium-40 Radium-226 Silver-108m U Thallium-208 Rad Gas Flow Proportional Counting 0.00731 0.0241 0.00+/-0.0284+/-0.0639+/-0.0563 0.00 0.0361 0.00+/-0.0284+/-0.064+/-0.0563-0.0741 +1-0.155 0.193 +/-0.155 0.00243 +/-0.133 0.143 +/-0.133 54.2 +/-15.0 11.0 +/-15.9 0.615 0.00706 0.528 0.501 0.0293 0.246 0.109).00648 0.0147 0.00 0.470 0.460).00378).00262 9.51 0.501-0.012 0.204+/-0.163+/-0.0254+/-0.246+/-0.095+/-0.0241+/-0.0396+/-0.0365+/-0.0436+/-0.0577+/-0.0588+/-0.047+/-0.0751+/-0.0226+/-0.0191+/-0.714+/-0.095+/-0.0156+/-0.0408 0.0558 0.0245 0.144 0.0294 0.0224 0.0178 0.0172 0.0405 0.0508 0.0358 0.0218 0.0294 0.0189 0.0163 0.143 0.0294 0.0134 0.0165+/-0.163+/-0.0254+/-0.246+/-0.095+/-0.0241+/-0.0396+/-0.0365+/-0.0436+/-0.0577+/-0.0588+/-0.047+/-0.0751+/-0.0226+/-0.0191+/-0.714+/-0.095+/-0.0156+/-0.0408 0.0777 0.158 0.0778 0.467 0.367 22.6 0.120 0.0503 0.306 0.0624 0.0473 0.0377 0.0377 0.0847 0.110 0.0739 0.0453 0.0615 0.0402 0.0345 0.319 0.0624 0.0284 0.0349 0.0179 10.6 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LCWl 05/18/06 1606 530940 1 LCWI 05/18/06 1605 530942 2 LCWI 06/03/06 0928 530943 3 MJH1 05/31/06 1727 528196 4 BXF1 06/06/062314 535512 5 NXPI 05/28/060219 531705 7 GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.01 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, Solid AII, FSS 0669 +/-0.00923 0.00862 +/-0.00923 5.45 +/-6.31 5.08 +/-6.31 58 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Proiect: YANKO 1204 Client ID: YANKOO Vol. Recv.: Client Sample ID: Sample ID: 9106-0003-008F 162335018 Parameter Qualifier Result Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0788 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -15.8 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.0786 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0613 The following Prep Methods were performed Method Description Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.115 0.0953 +1-0.115 0.194+/-16.9 13.2 +/-17.0 27.8 pCi/g pCi/g pCi/g pCi/g ATH2 06/05/06 1937 534837 8 AFI 06/05/06 1553 535483 10 SLNI 05/30/06 1451 527978 12 SXEI 05/31/06 0914 531704 13+/-2.26 1.89 +/-2.26 3.93+/-0.256 0.217 +/-0.256 0.445 Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/08/06 0826 527706 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-R 2 DOE EML HASL-300, Pu-I I-RC 3 DOE EML HASL-300, Pu-I I-RC 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 905.0 Modified 7 EPA 906.0 Modified 8 EPA EERF C-01 Modified 9 EPA EERF C-01 Modified 10 DOE RESL Fe-I, Modified 11 DOE RESL Fe-I, Modified 12 DOE RESL Ni-I, Modified 13 DOE EML HASL-300, Tc-02-RC C Modified Modified Modified Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALl Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Recovery%106 91 94 Acceptable Limits (15%-125%)

(15%-125%)

(25%-125%)

59 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-008F Project: YANK01204 Sample ID: 162335018 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 73 (25%- 125%)Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 91 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 85 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 62 15%- 125%)Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.60 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Cprtifieatp of Annlvqiq Company: Connecticut Yankee Atomic Power Address : 362 lnjun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0003-014F 162335019 Soil 25-APR-06 05-MAY-06 Client 16%Project: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.Curium-242 U Curium-243/244 U AIphaspec Pu, Solid ALL FSS Plutonium-238 U -0.Plutonium-239/240 U -0.Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 (Americium-241 U 0.0 Bismuth-212 (Bismuth-214 (Cesium-134 UUI Cesium-137 0 Cobalt-60 0 Europium-152 U -0.Europium-154 U -0.Europium-155 U 0 Lead-212 0 Lead-214 0 Manganese-54 UU1 Niobium-94 U 0.Potassium-40 Radium-226 C Silver-108m U -0.0'Thallium-208 0 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U-0.00i Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, Solid AIlFSS 0626 0.047 0.00 0512 0658+/-0.101+/-0.0921+/-0.0834 0.00 +/-0.102 0.00 +/-0.0924 0.00 +/-0.0834+/-0.167 0.197 +/-0.168+/-0.043 0.104 +/-0.0437 19.0 +/-13.1 10.4 +/-13.2).885 0545).476).559 0.00).291 1.433 0381 0112 1.080 1.927 1.733 0.00 0126 15.3 1.559 0262 1.333+/-0.165+/-0.0921+/-0.227+/-0.0801+/-0.0239+/-0.0402+/-0.0574+/-0.0372+/-0.0452+/-0.0686+/-0.0855+/-0.0906+/-0.0409+/-0.0136+/-1.40+/-0.0801+/-0.013+/-0.0443 0.0474 0.0757 0.107 0.0249 0.0171 0.0132 0.0112 0.0325 0.037 0.0431 0.0203 0.0247 0.013 0.0118 0.101 0.0249 0.0115 0.0119+/-0.165+/-0.0921+/-0.227+/-0.0801+/-0.0239+/-0.0402+/-0.0574+/-0.0372+/-0.0452+/-0.0686+/-0.0855+/-0.0906+/-0.0409+/-0.0136+/-1.40+/-0.0801+/-0.013+/-0.0443 0.115 0.127 0.115 0.476 0.291 21.5 0.0994 0.156 0.223 0.0518 0.0356 0.0275 0.0242 0.0675 0.0787 0.0885 0.042 0.0512 0.0272 0.0246 0.218 0.0518 0.024 0.025 0.0187 11.5 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g LCWI 05/18/06 1606 530940 1 LCW1 05/18/06 1605 530942 2 LCW1 06/03/06 0959 530943 3 MJHI 05/31/06 1728 528196 4 BXFI 06/06/06 2315 535512 5 NXPI 05/28/06 0251 531705 7 0963 +/-0.0092 0.00897 +/-0.0092 9.53 +/-7.00 5.52 +/-7.00 61 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: June 7, 2006 Client Sample ID: Sample ID: 9106-0003-014F 162335019 Project: YANKO 1204 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint CJ4, SolidA, FSS Carbon-14 U 0.'Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0+/-0.110 0.0919 +/-0.110 1.69 +/-16.2 12.1 +/-16.2-0.34 +/-2.43 2.05 +/-2.43 0.187 25.3 4.25 0.453 pCi/g pCi/g pCi/g pCi/g ATI-12 06/05/06 2038 534837 8 AF1 06/05/06 1610 535483 10 SLNI 05/30/06 1507 527978 12 SXEI 05/30/06 2109 531704 13.179 +/-0.268 0.219 +/-0.268 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B MXP2 05/08/06 0826 527706 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 05/07/06 1536 527705 The following Analytical Methods were performed Method Description I DOE EML HIASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified 3 DOE EML HASL-300, Pu- I -RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 905.0 Modified 7 EPA 906.0 Modified 8 EPA EERF C-01 Modified 9 EPA EERF C-01 Modified 10 DOE RESL Fe-I, Modified 11 DOE RESL Fe-I, Modified 12 DOE RESL Ni-I, Modified 13 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS 66 95 101 (15%-125%)

(15%-125%)

(25%-125%)

62 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 7, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-014F Project: YANK01204 Sample ID: 162335019 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 60 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 86 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 83 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 69 (15%-/125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria* Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.63 I, QUALITY CONTROL DATA 64 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client : Connecticut Yankee Atomic Power 362 Injun Hollow Rd Reuort Date: June 7, 2006 Page 1 of 9 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

162335 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Alpha Spec Batch 530940 QC1201095114 162335018 DUP Americium-241 Curium-242 Curium-243/244 QC1201095116 LCS Americium-241 Curium-242 Curium-243/244 QC1201095113 MB Americium-241 Curium-242 Curium-243/244 QC1201095115 162335018 MS Americium-241 Curium-242 Curium-243/244 U 0.00731 Uncert: +/-0.0284 TPU: +/-0.0284 U 0.0241 Uncert: +/-0.0639 TPU: +/-0.064 U 0.00 Uncert: +/-0.0563 TPU: +/-0.0563 12.7 Uncert: TPU: Uncert: TPU: 15.5 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 13.3 U 0.00731 Uncert: +/-0.0284 TPU: +/-0.0284 U 0.0241 Uncert: +/-0.0639 TPU: +/-0.064 16.3 U 0.00 Uncert: +/-0.0563 TPU: +/-0.0563 U 0.0412+/-0.144+/-0.144 U 0.00+/-0.179+/-0.179 U -0.0198+/-0.0389+/-0.039 11.5+/-1.12+/-1.97 U 0.00+/-0.0559+/-0.0559 13.4+/-1.21+/-2.24 U -0.0214+/-0.0615+/-0.0617 U -0.00758+/-0.0149+/-0.0149 U -0.00753+/-0.0148+/-0.0148 pCi/g 140 pCi/g 0 pCi/g 200 pCi/g (0%- 100%) ,CWI 05/18/06 16:06 (0%- 100%)(0%- 100%)91 (75%-125%)

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 85 (75%-125%)

U 11.9+/-1.21+/-2.09 0.00+/-0.0689+/-0.0689 15.5+/-1.38+/-2.61 90 (75%-125%)

95 (75%-125%)

Batch 530942 QC1201095122 162335018 DUP Plutonium-238 U -0.0741 U -0.0202 pCi/g 114 (0%- 100%) -CWI 05/18/06 16:14 65 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn QC Summary Workorder:

162335 Page 2 of 9 REC% Range Anist Date Time Parmname Rad Alpha Spec Batch 530942 NOM Sample Qual QC Units RPD%Plutonium-239/240 QC1201095124 LCS Plutonium-238 Plutonium-239/240 QC1201095121 MB Plutonium-238 Plutonium-239/240 QC1201095123 162335018 MS Plutonium-238 Uncert: +/-0.155 TPU: +/-0.155 U -0.00243 Uncert: +/-0.133 TPU: +/-0.133 Uncert: TPU: 11.7 Uncert: TPU: Uncert: TPU: Uncert: TPU: u -0.0741 Uncert: +/-0.155 TPU: +/-0.155 12.3 U -0.00243 Uncert: +/-0.133 TPU: +/-0.133+/-0.0595+/-0.0595 U 0.0157+/-0.0841+/-0.0842 0.128+/-0.125+/-0.126 11.8+/-1.21+/-1.72 U -0.0523+/-0.0953+/-0.0955 U -0.0933+/-0.101+/-0.101 U 0.070+/-0.0961+/-0.0964 10.5+/-1.06+/-1.49 pCi/g 273 (0%- 100%)(75%-125%)

pCilg pCi/g pCi/g pCi/g pCi/g pCi/g 101 (75%-125%)

05/18/06 16:05 (75%- 125%)05/18/06 16:14 Plutonium-239/240 85 (75%-125%)

Batch 530943 QC1201095126 162335018 DUP Plutonium-241 QC1201095128 LCS Plutonium-241 QC1201095125 MB Plutonium-241 Uncert: TPU: 330 Uncert: TPU: Uncert: TPU: 331 Uncert: TPU: 54.2+/-15.0+/-15.9 36.3+1-15.1+/-15.6 303+/-22.1+/-37.4 pCi/g 40 (0% -100%) LCW I U 14.0+/-13.6+/-13.6 pCi/g pCi/g pCi/g 92 (75%-125%)

06/03/06 11:01 06/03/06 12:04 06/03/06 10:30 06/03/06 11:32 QC1201095127 162335018 MS Plutonium-241 Rad Gamma Spec Batch 528196 QC1201088600 162335001 DUP Actinium-228 54.2+1-15.0+/-15.9 320+/-23.3+/-40.0 80 (75%-125%)

0.640+/-0.149 Uncert: 0.681+/-0.118+/-0.118 pCi/g 6 (0%-100%)

MJHI 05/31/06 17:31 66 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

162335 Page 3 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 528196 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU: +/-0.149 U 0.00555 Uncert: +/-0.0707 TPU: +/-0.0707 0.351 Uncert: +/-0.281 TPU: +/-0.281 0.462 Uncert: +/-0.0847 TPU: +/-0.0847 U 0.00674 Uncert: +/-0.0184 TPU: +/-0.0184 0.128 Uncert: +/-0.0361 TPU: +/-0.0361 0.107 Uncert: +/-0.0311 TPU: +/-0.0311 U 0.00641 Uncert: +/-0.043 TPU: +/-0.043 U -0.015 Uncert: +/-0.0505 TPU: +/-0.0505 U 0.0713 Uncert: +/-0.0618 TPU: +/-0.0618 0.670 Uncert: +/-0.0714 TPU: +/-0.0714 0.562 Uncert: +/-0.0771 TPU: +/-0.0771 U -0.0119 Uncert: +/-0.0207 TPU: +/-0.0207 U 0.0123 Uncert: +/-0.0151 TPU: +/-0.0151 10.9 Uncert: +/-0.996 TPU: +/-0.996 0.462 Uncert: +/-0.0847 TPU: +/-0.0847 U 0.0049 Uncert: +/-0.0138 U -0.00939+/-0.0817+/-0.0817 0.356+/-0.181+/-0.181 0.418+/-0.066+/-0.066 U 0.00496+/-0.0191+/-0.0191 0.131+/-0.0298+/-0.0298 0.108+/-0.0327+/-0.0327 U -0.00259+/-0.0383+/-0.0383 U 0.00694+/-0.0476+/-0.0476 U 0.033+/-0.0524+/-0.0524 0.640+/-0.048+/-0.048 0.561+/-0.0698+/-0.0698 U 0.00582+/-0.0176+/-0.0176 U 0.00253+/-0.0135+/-0.0135 10.5+/-0.705+/-0.705 0.418+/-0.066+/-0.066 U -0.001+/-0.0125 pCi/g 779 pCi/g I pCi/g 10 pCi/g 30 pCi/g 3 pCi/g I pCi/g 471 pCi/g 544 pCi/g 74 pCi/g 5 pCi/g 0 pCi/g 584 pCi/g 132 pCi/g 4 pCi/g 10 pCi/g 303 (0% -100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0%- 100%)(0% -20%)(0% -20%)(0% -100%)(0%- 100%)(0%- 20%)(0%- 100%)(0%- 100%)Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-I 08m 67 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Workorder:

162335 Parmname Rad Gamma Spec Batch 528196 Thallium-208 QC1201088601 LCS Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium- 134 Cesium- 137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 QC Summary Sample Qual QC NOM Units RPD%Page 4 of 9 REC% Range Anist Date Time TPU: Uncert: TPU: Uncert: TPU: 23.4 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 9.65 Uncert: TPU: 15.1 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.0138 0.229+/-0.0399+/-0.0399+/-0.0125 0.214+/-0.0444+/-0.0444 U 0.109+/-0.571+/-0.571 21.1+/-2.42+/-2.42 U -0.0642+/-1.13+/-1.13 U 0.196+/-0.247+/-0.247 U -0.013+/-0.147+/-0.147 10.2+/-0.895+/-0.895 15.8+/-1.18+/-1.18 U -0.084+/-0.302+/-0.302 U 0.416+/-0.330+/-0.330 U -0.213+/-0.356+/-0.356 U 0.105+/-0.180+/-0.180 U 0.00264+/-0.222+/-0.222 U -0.0501+/-0.138+/-0.138 U 0.0389+/-0.131+/-0.131 U 1.82 pCi/g 7 (0%- 100%)pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 05/31/06 17:32 90 (75%-125%)

105 (75%-125%)

104 (75%-125%)

68 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn QC Summary Workorder:

162335 Page 5 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 528196 Radium-226 Silver- 108m Thallium-208 QC1201088599 Actinium-228 Americium-241 MB Bismuth-212 Bismuth-214 Cesium- 134 Cesium-137 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncer: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-1.28+/-1.28 U 0.196+/-0.247+/-0.247 U -0.0876+/-0.113+/-0.113 U 0.0613+/-0.173+/-0.173 U 0.0748+/-0.0533+/-0.0533 U -0.0415+/-0.0619+/-0.0619 U 0.0557+/-0.0788+/-0.0788 UUI 0.00+/-0.0342+/-0.0342 U 0.00114+/-0.00936

+/-0.00936 U 0.00771+/-0.0187+/-0.0187 U 0.0159+/-0.0128+/-0.0128 U 0.00686+/-0.0288+/-0.0288 U -0.0183+/-0.0274+/-0.0274 U -0.00693+/-0.0229+/-0.0229 U 0.00357+/-0.0163+/-0.0163 U 0.00987+/-0.0198+/-0.0198 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 06/02/06 09:20 (75%-125%)

Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 69 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn QC Summary Workorder:

162335 Page 6 of 9 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Gamma Spec Batch 528196 Manganese-54 Niobium-94 Potassium-40 Radium-226 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: U 0.00383+/-0.00944

+/-0.00944 U -0.00371+/-0.00901

+/-0.00901 U 0.0777+/-0.178+/-0.178 UUI 0.00+/-0.0342+/-0.0342 U 0.000939+/-0.00928

+/-0.00928 U 0.0147+/-0.0161+/-0.0161 pCi/g pCi/g pCilg pCilg pCilg pCilg Silver-108m Thallium-208 Rad Gas Flow Batch 535512 QC1201105910 162335018 DUP Strontium-90 QC1201105912 LCS Strontium-90 QC1201105909 MB Strontium-90 QC1201105911 162335018 MS Strontium-90 Rad Liquid Scintillation Batch 527978 QCI201088148 162335018 DUP Nickel-63 U 0.00669 Uncert: +/-0.00923 TPU: +/-0.00923 1.43 Uncert: TPU:.Uncert: TPU: U 0.012+/-0.00902

+/-0.00902 1.19+/-0.081+/-0.0854 U 0.0107+/-0.00663

+/-0.00664 1.54+/-0.107+/-0.115 pCi/g 0 (0% -100%) BXFI pCi/g pCi/g pCi/g 83 (75%-125%)

06/06/06 23:16 06/07/06 10:08 06/06/06 23:16 06/07/06 10:08 1.54 U Uncert: TPU: 0.00669+/-0.00923

+/-0.00923 100 (75%-125%)

U 0.0786 Uncert: +/-2.26 TPU: +/-2.26 U QC1201088150 LCS Nickel-63 QC1201088147 MB Nickel-63-2.09+/-2.31+/-2.31 119+/-5.38+/-6.06 pCi/g pCi/g (0% -100%) SLNI 05/30/06 15:39 129 Uncert: TPU: 92 (75%-125%)

05/30/06 16:12 05/30/06 15:23 U -1.23 pCi/g 70 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

162335 Page 7 of 9 Parmname NOM Sample Qual QC Units RPD%REC% Range Anist Date Time Rad Liquid Scintillation Batch 527978 Uncert: TPU: QC1201088149 162335018 MS Nickel-63 134 U Uncert: TPU: 0.0786+/-2.26+/-2.26 Batch 531704 QC1201096868 162583001 DUP Technetium-99 QC1201096870 LCS Technetium-99 QC1201096867 MB Technetium-99 QC1201096869 162583001 MS Technetium-99

+/-2.03+/-2.03 122+/-5.70+/-6.37 0.239+/-0.273+/-0.273 11.1+/-0.474+/-0.545 pCi/g 91 (75%-125%)

05/30/06 15:55 U 0.161 Uncert: +/-0.254 TPU: +/-0.255 U pCi/g .0 (0% -100%) SXEI 05/31/06 00:27 12.5 Uncert: TPU: Uncert: TPU: 13.1 U Uncert: TPU: U 0.163+/-0.214+/-0.214 pCi/g pCi/g pCi/g 89 (75%-125%)

05/31/06 01:00 05/31/06 00:11 05/31/06 00:44 0.161+/-0.254+/-0.255 11.6+/-0.583+/-0.649 89 (75%-125%)

Batch 531705 QC1201096878 162583001 DUP Tritium QC1201096880 LCS Tritium QC1201096877 MB Tritium QC1201096879 162583001 MS Tritium U 1.17 Uncert: +/-4.09 TPU: +/-4.09 U 6.01+/-4.70+/-4.70 pCi/g 0 (0% -100%) NXP I 41.4 Uncert: TPU: Uncert: TPU: 45.7 U Uncert: TPU: 44.8+/-5.68+/-5.73 U 0.0641+/-0.533+/-0.533 pCi/g pCi/g pCi/g 108 (75%-125%)

05/28/06 09:10 05/28/06 10:14 06/03/06 05:11 05/28/06 09:42 1.17+/-4.09+/-4.09 Batch 534837 QC1201104385 162335019 DUP Carbon- 14 QC1201104387 LCS Carbon- 14 U 0.0228 Uncert: +/-0.110 TPU: +/-0.110 U 52.3+/-6.44+/-6.50 0.0418+/-0.121+/-0.121 6.52+/-0.238+/-0.259 114 (75%-125%)

pCi/g pCi/g (0%- 100%) ATH2 06/05/06 22:40 6.66 Uncert: TPU: 98 (75%-125%)

06/04/06 08:22 71 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

162335 Page 8 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Liquid Scintillation Batch 534837 QC1201104384 MB Carbon- 14 QC1201104386 162335019 MS Carbon- 14 Uncert: TPU: U 0.0371+/-0.125+/-0.125 pCi/g pCi/g 06/04/06 06:04 06/04/06 07:36 7.13 U Uncert: TPU: 0.0228+/-0.110+/-0.110 Batch 535483 QC1201105873 162335018 DUP Iron-55 U -15.8 Uncert: +/-16.9 TPU: +/-17.0 U 7.04+/-0.249+/-0.272 0.079+/-20.4+/-20.4 492+/-39.7+/-61.9 99 (75%-125%)

pCi/g 0 (0%- 100%) AFI QC1201105875 LCS Iron-55 QC1201105872 MB Iron-55 485 Uncert: TPU: Uncert: TPU: 655 U Uncert: TPU: U 5.04+/-22.8+/-22.8 pCi/g pCi/g pCi/g 101 (75%-125%)

06/05/06 17:00 06/05/06 17:33 06/05/06 16:43 06/05/06 17:16 QC1201105874 162335018 MS Iron-55-15.8+/-16.9+/-17.0 628+/-39.8+/-71.2 96 (75%-125%)

Notes: The Qualifiers in this report are defined as follows: A BD C D H J N/A R U UI X Y A A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported The TIC is a suspected aldol-condensation product Results are either below the MDC or tracer recovery is low Analyte has been confirmed by GC/MS analysis Results are reported from a diluted aliquot of the sample Analytical holding time was exceeded Value is estimated Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.Gamma Spectroscopy--Uncertain identification Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL Preparation or preservation holding time was exceeded 72 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

162335 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time h N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.** Indicates analyte is a surrogate compound.^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.73 General Narrative Page 1 of 105 CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 168404 SDG: MSR #06-0652, 06-0675, 06-0687, 06-0688, 06-0707, 06-0743, 06-0755 August 15, 2006 Laboratory Identification:

General Engineering Laboratories, LLC Mailing Address: P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address: 2040 Savage Road Charleston, South Carolina 29407 Telephone Number: (843) 556-8171 Summary: Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL)in Charleston, South Carolina on May 5, May 9, May 12, May 17, May 26, June 2, June 8, 2006. All sample containers arrived without any visible signs of tampering or breakage.

The chain of custody contained the proper documentation and signatures.

The laboratory received the following sample(s):

Sample ID Client Sample ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01 OF 168404008 9106-0005-014F 168404009 9106-0006-005F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712

  • Charleston, SC 29417
  • 2040 Savage Road (29407)Page 2 of 105 Phone (843) 556-8171
  • Fax (843) 766-1178
  • www.gel.com 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F Items of Note: At the request of Dale Randall on July 20, 2006, GEL analyzed the above samples according to the spreadsheet in the attached email.Case Narrative:

Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures.

Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.

Analytical Request: Seven soil samples were reanalyzed for FSSALL, except gamma and Sr-90.Four soil samples were reanalyzed for FSSALL, except gamma and Ni-63.Two soil samples were reanalyzed for FSSALL, except gamma.Two soil samples were reanalyzed for FSALL, except gamma, Sr-90 and Ni-63.Internal Chain of Custody: Custody was maintained for the sample(s).

Data Package: The enclosed data package contains the following sections:

Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.P.O. Box 30712

  • Charleston, SC 29417 -2040 Savage Road (29407)Phone (843) 556-8171
  • Fax (843) 766-1178
  • www.gel.com Page 3 of 105 Additional HTD analyses

Subject:

Additional HTD analyses From: "Dale Randall" <randall @cyapco.com>

Date: Thu, 20 Jul 2006 11:04:54 -0400 To: "Cheryl Jones" <cj@gel.com>

16 8, LI o (4, (CC: "Clyde Newson" <Newson@CYAPCO.com>, "John McCarthy" <McCarthy@

CYAPCO .com>Cheryl: Per our earlier discussion, attached is a list of samples that we would like to have analyzed to the FSSALL protocol.

I have included a list of test protocols performed on each sample to date. Once you have had an opportunity to determine our options for each sample please call or e-mail me at your convenience.

Thank You, Dale (860) 267-3133 Content-Description:

GEL FSSALL analyses request.xls GEL FSSALL analyses request.xls!

Content-Type:

application/vnd.ms-excel Content-Encoding:

base64 Page 4 of 105 I oflI 812/2006 7:04 PM.1l, x x x x x x x x x x x 'C x x x x x X x X x X X"x x x CXIX xXIXx x x x"x xxx x Xxlx x Cx xI x Xx x x 'Cxx xI'x xx x X1 x'C X x x xx x x x x x x x x'x x x x x x X XC x ...E xC'C x x x x x x x x x 0 0 x x x x x x z 0)LLu-LLLLLLLLLLLLLLLLLLLLLLLLL 00 U- C9 99 9 9 9 o~~~~ C)- C) tU)) 0 '0 C) n \ a~ -CsJ-0 .-) 0. 0-o- 0000 0-M000000000000000

.2 cli C\j m m Cl) c~l LOLL COC qC)C) 0 0)0 u 00000 N 000000 , c mC o 2.)c O ot c) C) ' -1 ragec 0 o IUD Chain of Custody and Supporting Documentation Page 6 of 105 Health Physics Procedure 16 5 CIO (ýGPP-GGGR-R5 104-003 -Attachment B-CY-001 Major CD Chain of Custody Form Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 No. 2006-00371 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 Cn3 r. OA 843 556 8171. Attn. Cheryl Jones r 4 Priority:

9 30 D. [114 D. [17 D. Container Sample Size- ,..Media Type &Type " Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-OO1F 5/17/06 10:42 SE C BP X X Transferred from COC 2006-00357 9106-0002-002F 5/18/06 09:43 SE C BP x Transferred from COC 2006-00361 9106-0002-003F 5/18/06 10:14 SE C BP X X Transferred from COC 2006-00361 9106-0002-004F 5/18/06 10:39 SE C BP X X Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP X X Transferred from COC 2006-00364 9106-0002-006F 5/18/06 13:14 SE C BP X x -.-.- Transferred from COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP x X Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:37 SE C BP x X Transferred from COC 2006-00364 9106-0002-008F 5/18/06 14:04 SE C BP x X Transferred from COC 2006-00364 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA F1 Radwaste QA [ Non QA Samples Shipped Via: Internal 0[5 Fed Ex Container' UPS Temp.: Deg. C E0 Hand Custody Sealed?I Date/Time

2) ivd By Date/Time Custody Seal eJ 3. M- C\ ) C. Other Intact?;elinquished B.. Date/Time
4) Received By Date/Time BillofLaing___710YD NO Bill of Lading #5) Relinquished By -Date/Time" 6) Received By "Date/Time 7q0'? '7///YS6 5,7/ &)

Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 1 MajorChain of Custody Form Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 No. 2006-00372

-Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones rA 4 Priority:

Z 30D. El 14 D. [U17 D. Container Sample Size-Media Type &Type C-Sample Designation Date Time Code Code Code -r-n-e-e-Comment, Preservation Lab Sample I2 9106-0002-009F 5/18/06 14:28 SE C BP x Transfeed from COC 2006-00364 9106-0002-01OF 5/18/06 14:50 SE C BP x x Transferred from COC 2006-00364 9106-0002-01 IF 5/19/06 08:10 SE C BP X x Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP x x Transferred from COC 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP x x Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP X x Transferred from'COC 2006-00365 9106-0002-014FS 5/19/06 09:58 SE C BP X Transferred from COC 2006-00365 9106-0002-015F 5/19/06 10:29 SE C BP x x Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP x X Transferred from COC 2006-00365 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [D LTP QA [] Radwaste QA ED Non QA Samples Shipped Via: Internal , Fed Ex Container E UPS Temp.: Deg. C[ Hand Custody Sealed?1 j Date/Time

2) Re ived By Datime Custody Seal 2 ~ved- I nat__ _ _ _ E] Other Intact?

ished BY Date/Time

-4) Received By Date/Time Bill...Lading#

Y N Bill of Lading #5) Relinquished By Date/Time

6) Received By Date/Time 7909 *//46"j Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-OO1 Figure 1. Sample Check-in List Date/Time Received 90 SDG#: Work Order Number: Co, Lt.{-C'".Shipping Ccntainer ID') O 4'1 %" t[5.5 /0 Chain of Custody# f0 (0 C" 9/1. Custody Seals ori shipping container intact?.-

Yes No [ ]2. Custody Seals dated and signed? Yes No[J.3. Chain-of-Custody record present? Yes []No'A4. Cooler temperature

5. Vermiculite/packing materials is:. Wet [ Dry 1lO t tC~iA " 6. -Number of samples in shipping container:

,. _ _ _ "_' _" 7.= Sample holding times_. _ ..exc'eeded?

'Yes 8. Samples have.tape labels K. scustody seals -appropriate sample labels 9. Samples arei)(--in good condition Jeaking.broken ----have air bubbles 10. Were any anomalies identified in sample receipt? yes. No)(*. 1 I Description of anomalies, (include sample numbers): Sample. Custodian/Laboratory:

Date.. "0(4o Telephoned to: ..On By Page 9 ofO.105 Connecticut Yankee CYISCS " " Statement of Work for Analytical Lab Services C ..CY-ISC-SOW-OOl Figure 1. Sample Check-in List, DatefTimne Received -',- &4.9 SDG#: L-(Work Order Number: l f'Shipping C4:htainer ID.p L i~ T Cano Cutdy #QD I. Custody Seals. or; shipping container intact? -Yes. No []2. Custody Seals dated and signed? Yes No [No 3. Chain-of-Custody record preent? Yes ~~No[4. Cooler temperaturc

.5. Vermiculite/packing materials is: 'Wet [ I Dry 6.: Number of samples in shipping container

_7. Sample holding times exceeded?

Yes [ No~,Lue+8. Sam have:__ape, hazard labels custody seals .appropriate sample labels 9. Samples are-_)L in good condition leaking broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [1 No 11. *Description of anomalies (include sample numbers): Sample Custodian/Laboratory: ,i" ;1p .4, .Date" Telephoned to: On By.Page 10 of 105 SAMPLE RECEIPT & REVIEW FORM JTORIO"PM use only CliCt tn7T k t-ISDG/ARCOC/Work Order: Date Received:

JM(A) Review(esre non(confoflitig items ar resolyed prior to signing);Received By: Sample Receipt Criteria CommentslQualifiers (Required for Non-Conforming Items)Shipping containers received intact Circle Applicable:

seals broken damaged container container o.her (dcribe)1 and sealed? .7 Samples requiring cold Circle Coolant # ice bass blue ice / dry ice none other describe)2 preservation within (4 +1- 2 C)?Record preservation method.Chain of custody documents

.included with shipment?Sample containers intact and Circe'^pplcab

.: sbroken damaged container itakingeontainnr o 4 sealed? , _ _ _ _. ... ... .. ...5 Samples requiring chemical kSa If Mls. containers affected and observed p"-preservation at proper pH? ........__.___VOA vials free of beadspace Sample ID's and containers affected: 6 (defined as < 6mm bubble)?7.___.

Are Encore containers present?7 (If yes, immediately deliver to!VOA laborator)

____ _ _____ _ "--_-d-8 Samples received wi holding Id's and tests affected time?9 Sample ID's COC match ID's Sample ID's and containers affectedt:

on bottles?___

0Date &me on COC match date Sample ID's affected:& tirP6 on bottles?i Nutber of containers received Sample ID's affcted: match number indicated on COC?COC form is properly signed in 12 relinguished/reccived sections?

___ 0__&______2_004_e

_. on____14 Air Bill ,Tracking

  1. 's, &Additional Comments., > RSO RAD Receipt #Suspected Hazard Information

!*fS> x2 area background is observed on samples identified as "non-ud ' regulatedlnon-radioactive', contact the Radiation Safety group for further___ __ ___ [ investigation.

rRadiological Classification?

Maxiimum Counts Observed* (P47 B CB Regulateid?

Cl Omments: Sipdas DpI' Hazardous C .eral? If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. = UN#:-PM (or PMA) review of Hazard class~ftkation-ntal:Z Page II of 105

.lG/4 SAMPLE RECEIPT & REVIEW F:*4 rOgl PM use only ,- ' ,, -' (,J _ .. ,.-,-, ,,.,n-,.-.

I(.. 4'ZZO ORM I , t I-ateR : Review re on-conor are resolvedl prior to signing): Date Received:

(, -:;4 Ofo PM(A) Reflvi r Received By: -Sample Receipt Criteria Comments/Qualifie rs equired for Non-Conforming Items)Shipping containers received intact Circle Applicable:

seals broke damaged container leaking container other (describe) and sealed? ... .. .._._._._,_

_ _ _ __.Samples requiring cold Circ Coolant # 7Yiags blue ice dry ice none other describe)2 preservation within (4 +/- 2 C)? /Record preservation method.Chain of custody documents included with shipment?Sample containers intact and pplicable:

seals broken damaged container leaking container other (describe) sealed? 7.Samples requiring chemical, ample IU's. containers affected and observed pH: preservation at proper pH? I... .VOA vials free of headspace Sample ID's and containes affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VO A laboratory)

...._ __..... ... .... ...Samples received within holdin id's and tests affected.8lime?9 Sample ID's on COC ma c lD's Sample ID's and containers affected: on bottles?__

_ _ _ __ _Date & time on COC tch date Sample ID'S affected:& time on bottles?Number of containe received Sample ID's affected: match number indic.ted COC form is propirly signed in 4"-1 relinguished/recgived sections?

1ccc Z OCG Air Bill ,Tracking

  1. 's, &Additional Comments=
  • RSRAD Receipt #___________

C4 *If > x2 area background is observed on samples identified as Ron-Suspected Hazard InformationU c- .regulated/non-radioactive".

contact the Radiation Safety group for further!E investigation.

A Radiological Classification?

[ 1/ Maximum. Counts Observed*.'

r ..BPCB Regulated?

Comments: shipped as DZY' azardous I Material?

If yes, contact Waste Hazard Class Shipped: PM (or PMA) review of Hazard classification:

Page 12 of 105 0 Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major~Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00312

2. 362 Injun Hollow Road, East Hampton, CT 06424 !S Z j9 4 I.933- '/ :9'6 W860-267-2556

%___________________I'___

0 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only., J Contact Name & Phone: Corents: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC, 29407 843 556 8171. Attn. Cheryl Jones Priority:

0 30 D. E] 14 D. El 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample 1D 9106-0003-OOIF 4/24/06 14:13 SE C BP x Transferred from COC2006-00221 p" 9106-0003-002F 4/24/06 14:39 SE C BP x Transferred from COC2006-00221

"' 9106-0003-003F 4/24/06 15:01 SE C BP x Transferred from COC2006-00221 9106-0003-004F 4/25/06 08:41 SE C BP x Transferred trom COC2006-00223 9106-0003-004FS 4/25/06 08:41 SE C BP X Transferred from COC2006-00223 9106-0003-005F 4/25/06 09:21 SE C BP X Transferred from COC2006-00223 9106-0003-006F 4/25/06 09:46 SE C BP X transferred from COC2006-00223 9106-0003-007F 4/25/06 10:28 SE C BP X Transferred from COC2006-00223 9106-0003-008F 4/25/06 11:15 SE C BP X Transferred from' COC2006-00223 NOTES: PO #: 002332 MSR #: 0 6-c -" SSWP# NA [ LTP QA El Radwaste QA E Non QA Samples Shipped Via: nitern'lal.Cotiner Combined samples 9106-0003-003F taken on 4/25/06 @08:19 and 9106-0003-003FB taken on 4/25/06 @ 08:19 in order to have sufficient sample for counting.

Z Fed Ex n.:ip" : .Deg& C,;[ Hand Custody Sealed?7,.

1) Relinquished By Date/Time
2) /ec ived By / DateiTime CiStbdy lSeql Intk.t?' gh ,(, ..5-4Y. / J.'3 0 ( 1 (d tlt 5/ 1GiII Other 3) Relinquished By Date/Time
4) Received By Date/Time

_ _ __ _ YF .. ..Bill of Lading : 5) Relinquished By Date/Time

6) Received By Date/Time

.-92O- '52C- 52 4.

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Maj or CD 00 okc 00~00l Chain of Custody Form No. 2006-003 13 Connecticut Yankee Atomic Power Company C 362 Injun Hollow Road, East Hampton, CT 06424 ., 960-267-2556

-', -35V.Project Name: Haddam Neck Decommissioning Analyses Requested Contact Name & Phone: its.: ....Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 n 843 556 8171. Attn. Cheryl Jones (n Priority:

30 D.l 14D.[-7D.

Container

.'; .' .'Sample Size-Media Type &Type Sample Designation Date Time Code Code Code ----- -Comment, Preservation S: i i ..- TV 9106-0003-009F 4/25/06 13:00 SE C BP X Transferred from COC 2006-00236 9106-0003-010F 4/25/06 13:23 SE C BP X -- -ransfertedfromCOC2006-00236 9106-0003-01OFS 4/25/06 13:23 SE C BP X Transferred from COC 2006-00236 9106-0003-01"2F 4/25/06 15:12 SE C BP X Transferred from COC 2006-00236 9106-0003-013F 4/25/06 14:21 SE C BP X Transferred from COC 2006-00236 w, 9106-0003-014F 4/25/06 14:48 SE C BP X Trandferred from COC 2006-00236

." 9106-0003-015F 4/26/06 08:16 SE C BP x Transferred from COC 2006-00237

  • , 01 0e.AiOO.O1 iW Ar/9 001+/-1 I ~P.lqP IomO 1 91600307F42/0 9:8 S C B I Transferred from COC 2006-00237 I ':.<0-9106-0003-018F 4/26/06 08:59 I SE 1 C BP xI I T ansferred from COC 2006-00A3 I 4/26/06 08:59 SE I c NOTES: PO #: 002332 MSR #: 06- 0&SSWVP# NA Z LTP QA E! Radwasfe.

nA E] Non QA 1) Relinquished By Datwiime 2) eceived By DateiTime 3)1Rlin quseo b ae e4 cD /T 3) Relinquished By Date/Time

4) Received By °Dafe/Time Samples Shipped Via:[ Fed Ex 11UPS LI Hand El Other Bill of Lading #:092O-S0120-02/

a] gpj"jC g 1~i~sod 4 'De~l~tc mYL p ND Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-OO 1 Figure 1. Sample Check-in List Date/Time Received:_

.* 6 SDG#:____A t{ fo6-o~Work Order Number: -(.'Z- 3 5 ShippingCctntainer ID: 0 'i(. 017--1ChainofCustody#

1(25" -kO0-40) 0.(.) (1. Custody Seals od shipping container intact?., *yes .[ No 2. Custody Seals dated and signed7 Yes [N No 3. Chain-of-Custody record present? Yes No [ ].4. Cooler temperature .C-5. Vermiculite/packing materials is: Wet Dryti 6. Number of samples in shipping container

y [.7. Sample holding times exceeded?

Yes [ I No A.8 Sainp~les V tape --hazard labelsýZ custody seals appropriate sample labels 9. Samples are:'good condition -Ieaking-.broken .have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ ] No 1 I., .Description of anomalies (include sample numbers): Sample. Custodian/Laboratory:j[Ld(L C-4c, a Telephoned to: On -By___Page15of1 5-1 SAMPLE RECEIPT & REVIEW FORM PM use Gely i (023!... .R d 5PM(A) Review (ensure non-onforuing items are resolved prior to signing): Received By: (2. ,QirV- " cc_I 1 Sample Receipt Criteria Z Comments/Qualifiers (Required for Non-Conforming Items)SShipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (describe)

Iand sealed? I 0---=,,,,4"_

Samples requiring cold Circlc Coolant # ice bags blue ice dry ce none 2 preservation within (4 +/- 2 C)?Record preservation method. P__ _ _ e_ _ _ _r_, n__-H_ " Chain of custody documents included with shipment?

_,_Sample containers intact and Circle Applicable:

seals ibrken damaged container leaking container other (describe) sealed?5 Samples requiring chemical Sample ID's. containers aftected and obsmved pH: reservation at ro r H? I 6 VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)? ._..Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory) 8Samples received within holding Id's and tests affected.time? I 9 Sample ID's on COC match ID's Sample ID's and containers affected: on bottles?Date & time on COC match date Sample ID's affected:& time on bottles?Number of containers received Sample ID's affected: match number indicated on COCI COC form is properly signed in relinquished/received sections?14 Air Bill ,Tracking

  1. 's, & a. d ' 'q .2 6 02-(..Additional Comments I b 2 (4 0-V RSO RAD Receipt #__Information
  • If > x2 area background is observed on samples identified as 'non-SH Q regulated/non-radioacrve", contact the Radiation Safety group for further__ investigation.

rA Radiological Classification?

Maximum Counts Observed*:

B PCB Regulated?

Comments: Shipped as DUI Hazarous C Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager. UN#: PM (or PMA) review of Hazard classification:

Initials Date:[Page 16 of 105 C/0 1 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

[0 30 D.E] 14 D. [] 7 D.Samples Shipped Via: ED Fed Ex El uPs E3 Hand[I Other Bill of Lading #

Health Physýs. PriiýIedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major 0 1 CQn1 pi.p4 Yankee Atomic Power Company; 6triZjun Hollow Road, East Hampton, CT 06424 860-267-2556 Chain of Custody Form No. 2006-00337 C I Y -I -I -I Project.Name:

Haddam Neck Decommissioning Analyses Requested v Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 I I.Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

M 30 D. [] 14 D. U 7 D.0/0 I-Sample Designation Media Code Sample Type Container Size-&Type Date Time~DaeCd oe Code Cormment PreservationI 9I06-0004-008.F..

5/04/06 08:58 SE C BP x x Transferred from COC 2006-00320 9106-0004-009P,,, 5/04/06 08:23 SE C BP X X Transferred from COC 2006-00320 9106-0004-010

., 5/03/06 15:11 SE C BP x X Transferred from COC 2006-00317 9106-0004-01OFS

-' 5/03/06 15:11 SE C BP X X Transferred from COC 2006-00317 9106-0004-011IF,-

5/03/06 13:08 SE C BP x x Transferred from COC 2006-00317 9106-0004-012F¢/

5/03/06 13:33 SE C BP x x Transferred from COC 2006-00317 9106-0004-013F-" 5/03/06 13:54 SE C 13P X X Transferred from COC 2006-00317 9106-0004-014F.

5/03/06 14:43 SE C BP X x Transferred from COC 2006-00317 9106-0004-015F , 5/03/06 14:18 SE C BP X X Transferred from COC 2006-00317 I.NOTES: PO #: 002332 MSR #: 06- a04 p SSWP# NA SLTP QA E] Radwaste QA E] Non QA Samples Shipped Via:[ Fed Ex El ups El Hand IL 1) Relinquished Iy Date/Time

2) R ived y Date/Time 3) Relinquished By Date/Time ed By Date/Time E[ Other I Bill of Lading #I ...

Connecticut Yankee Statement of Work for Analytical Lab Services cY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:

,'- /1. o.f*SDG#: /14t O fL O -O , Work Order Number: -( 21 1 Shipping Container ID: Z3 1 1. Custody Seals on shipping container intact?2. Custody Seals dated and signed?3. Chain-of-Custody record present?4. Cooler temperature

5. Venniculite/packing materials is: 6. Number of samples in shipping container:
7. Sample holding times exceeded?6 ' ,' , 0-CY-ISC-SOW-O01 Chain of Custody# 0oo .- 6013"1 Yes No []Yes No []Yes No (]/Wet If Dry [ ]Yes [] No 8. Samples have:_tape -hazard labels_.r custody seals _ _appropriate sample labels 9. Samples are:_ in good condition

_..__leaking broken have air bubbles 10. Were any anomalies identified in sample receipt? Yes No []11. Description of anomalies (include sample numbers): Sample Custodian/Laboratory: , Lýc..,-b.,'.

Date: ..o , 9. o I Telephoned to: On By Page 45 of 56 Page 19 of 105 Connecticut Yankee Staiement of Work for Analytical Lab Services CY-ISC-SOW-00O Figure 1. Sample Chc.k-in List.Date/TimeReceived.:

/Jr)DIRP " SDG#: /JS~~(Work Order Number:._

___________________

  • , -X 3b9= 5 8 ebq .Shipping Cdatainer ID: _t" Chain of Custody# AD)O( -no 1.. Custody Seals od shipping container intact? -Yes ] No j4)2. Custody Seals dated and signed? Yes[ ] ..No 3. Chain-of-Custody rc~ord present? Yes ' No [1 4. Cooler ýemperature_,_

_ _ _ __ _ " 5. vermiculite/packing materials is: wet E4Diy 6.: *Number ofsamples in shipping container

",_-_"_._

__7. Sample holding timeS exceeded?

e.,. * .-Yes [ ]No 8.Samiples have:--2Qtape-hazard labels A..ý2custody seals .. appropriate sample labels 9. Samples ar.e:---n good conditiono-

--Jeokig"--have air bubbles 10. Were any aomali esidentified in sample receipt? Y -N" Yes/ No.[ J* .Sarnple Custoianw

~ .(~ hl Dtra/2I(ll..~~~Dte I,"*":..Telephoned to-__ _ ____________

.*. , ... ... .. ... ........ ...........

Page 20 of 105 SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM AedL2.voL...: &4 cp ro:+(t n(Ke (a- 5 G5 (00 -sv bLL5f ec, 5 CLrpU II 06 ts-54 p.- 6( , '"" Co ,* (F,~~AJ 1i~_ _ __ _ _ _ _ _Page 21 of 105 1!1! 1 0 SAMPLE RECEIPT & REVIEW FORM a, PM use only Client: C41 SDG/ARCOC/Work Order: /4' -z3z.Date Received:

  • -/. o PM(A) Review (ensure non-conforming items are resolved prior to signing): Received By:- k&,h- -O-- ..Sample Receipt Criteria A Comments/Qualiniers (Required for Non-Conforming Items)Shipping containers received intact Cirie Applicable:

seals broken damaged container leaking container other (describe) and sealed? , , Samples requiring cold Circle Coolant # ice bags blue ice dry ice rom other describe)2 preservation within (4 +/- 2 C)?Record preservation method. __Chain of custody documents included with shipment?

ad 4 Sample containers intact and Circle A ic ssok dg cone , F oe(dsb)sealed? : 21 a t( oe OoO0 -t a1 " 5 Samples requiring chemical Sample M's. containers affected and observed pH: preservation at proper pH? __VOA vials free of headspace Sample ID's and containers affected: (defined as < 6rmm bubble)? _Are Encore containers present?7 (If yes, immediately deliver to_VOA laboratory)x 8Samples received within holding Id's and tests affected:..

.9 Sample ID's on COC match ID's ll nple ID's and contaiaew affected-on bottles?10 Date & time on COC match date m ID's af ....& time on bottles? __....I1 Number of containers received Samp I's affce: match number indicated on COC?12 COC form is properly signed in relinquished/received sections?

i(-od. A.o'- #5 k el Air Bill ,Tracking

  1. 's, &Additional Comments Suspected Hazard Information
  • x2 area background is observed on wamples identified as 'aon-.regulatedthon-radioactive, contact te Radiation Safety group for.further

! Radiological Classificatio=

Vd B PCB. Regulat 7-~~~ X _ ... .7:- "com,,enwtS:*

'c Material?

If yes, contact Waste r Cls Shipped: Manager or ES Manager. y UN#: P? Pff4}yqw of Hazard classification:

Initials A. Date: --z.(.1 SAMPLE RECEIPT & REVIEW FORM 0 iPM use only IClient: +/l J(Y o n " SD1/ARCOCIWork Order: /6Z 2.2.Date Received:

=71 PM(A) Review (esure now onfoar hemsare resolved prim to ii: Received By: C r7}e vr 1 CA-1 I_____Sample Receipt Criteria Comments/Qualifiers (Required for Items)I Shipping containers received intact Circle Applicable:

seals broken damaged comainer leaking comnaier other {describe) and sealed? .....Cooant __icebags blueice dry_ ce______ therdescibe Samples requiring cold Circi Coola # ice bas blue ice dry ice edbr descriic)2 preservation within (4 +/- 2 C)?-Record preservation method. Vq '-, Chain of custody documents O S. C"X E> V tA-included with shipment?._

coomnse 4 Sample containers intact and i W"cc: stts "I edamaged comaim leaking omier sealed? c3 ' M15 Samples requiring chemical Sam* ID's. containers affected a=W observed pH: preservation at proper pH? I _, _... ._ __...... .. ..._'VOA vials free of headspace le ID's and containers atieced: 6 (defined as < 6mm bubble)? _Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)___

_______.8 amples received within holding Id'j and tests aftned: time?Sample ID's on COC match ID's ample ID's and co-aines affected: on bottles?Date & time on COC match date ampe ID's affemed:& time on botles?Number of containers received smple ID's affected: match number indicated on COC?COC form is properly signed in Ctks "L vwrv invoCt 12relinquished/received sections?14Air Bill ,Tracking

  1. s, & qu~SheA Additional Commentsl RSORADReceipt

__'~ j ~*If> x2 area- background is observed on samples identified as "non-Suspected Hazard Information

.z reguIated/non-radioactive, contact the Radiation Safety group for further__ a___d ____,____

investigation.

A Radiological Classification?

Maximum Counts

' : ... e .A.B PCB Regulatvd?

omments: IShpped as OT1 Hazardous Ci Material?

If yes, contact Waste I Hazard Class Shipped: IManager or ESH Manager.-

IUNI: PM (or PMA) review of Hazard classification:

Initials Date: -Page 2 rF I z -f Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major HelhPyisPoidr P-GRR I 0-0 Atahet IIYO 1 ao Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Contact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

Ig 30 D. [] 14 D. [] 7 D.Date[] Other Bill of Lading #1q7'719iS tI/3ISZ

-Connecticut Yankee Statement of Work for Analytical Lab Services.CY-ISC-SOW-O01 Figure 1. Sample Check-in List.Date/Time Received:

0 SDG#: A Work Order Number: \-,2- 'A "[.Shipping Container ID: -" L41-3 Chain of Custody #. -006 & g/ Oc 19 I. Custody Seals ori shipping container intact? YesP4f No[]2. Custody Seals dated and signed? Yes 4No [ ]" 3. Chain-of-Custody record present? Yes J No []4. Cooler temperature Ik 9./, 1 " 5. Vermiculite/packing materials is: Wet [WIDry , J 6. Number ofsamnplw in shipping container:

I" 7. Sample holding times exceeded?

Yes [ ] No 8. Sampleshave:-hazard labels_zcustody seals -appropriate sample labels 9. Samples are.: 9.Smpe aein good condition'

..,/leakin, (Ssi* e 4.S)* broken -have air bubbles 10. Were any anomalies identified in sample receipt? Y No I .Description of anomalies (incude e numbers): Sample CustodiantLaboratory:

Date: ' C2d O"I?1)Telephoned to: On By,._" Page 25 of 105 I SAMPLE RECEIPT & REVIEW FORM r FIM use only Client: SDG/ARCOCIWork Order: IG7vf85 Date Received:

PM(A) Review (ensure non-confornuig items are resolved prior to signing): Received By: _._I-(I-Sample Receipt Criteria ZO Comments/Qualifiers (Required for Non-Conforming Items)Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (describe) a sealed?Samp- requiring cold Circle Coolant # ice bags blue ice dry ice none other describe)2 preservati within (4 +/- 2 C)?Record reserv n method.3 Chain of custody do nts i included with shipment?t?

..4 Sample containers intact and Circle Applitable:

seals broken damaged container leaking continer other (describe),sealed?S Samples requiring chemical Sample ID's. containers affected and observed pH: preservation at proper pH?6 VOA vials free of headspace Sample ID's and containers affected:--(defined as < 6ram bubble.. )?jAre Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

Samples received within holding Id's and e afct.e o_ time? --Sample ID's on COC match ID's Sample ID's and containers affected: on bottles?Date & time on COC match date Sample ID's affected:-& time on bottles?Number of containers received Sample ID's affected: match number indicated on COG?12 COC form is properly signed in relinquished/received sections?14 Air Bill ,Tracking

  1. 's, & F41 -5'T. 9 ! 5 4 2 -- /7 1 C--Additional Comments 4210'tO 8 3 m c.-V 0 RSO RAD Receipt #Suspected Hazard Information o " -lf> x2 area backgrounda is observed on samples identified as Qnon--- reuae/nnrdatv contact the Radiation Safety group for hffrter 04 iZ ,invesigation.

A Radiological Classification?

-Maximun Counts Observed*:

B PCB Regulated?

/00 ommnts_Shipped as DOT Hazardous H C Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager.PM (or PMA) review of Hazard classification:

Initials Date: 715 77 I-aur, /-U 01 1 Vj U, Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424"Project Name: Haddam Neck Decommissk

ýZontact Name & Phone: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority:

Z 30 D. E] 14 D. [I 7 D.Samples Shipped Via:[ Fed Ex El uPs El Hand[] Other Bill of Lading #*92o- 7. 1o- ,

Connecticut Yankee Statement of Work for Analytical Lab Services , CY-ISC-SOW-O01 Figure 1. Sample Check-in List.Date/Time Received-:

cr! .Z (D SDG#A k ..-Work Order Number._ /_________________

Sipping Cdhtainer ID):- S9," Sipn Chain of Custody'#

S Q (C ' V ' /I. Custody Scals ojinshipping container intact?.... -Yes t No V(-2. Custody Seats dated and. signed? Yes H No 3. Chain-of-Custody record present? Yes (P)No []-4. Cooler.te.perature I C">5. Vermiculite/packing materials is: -Wet o) Dry J, ]6.: Number ofsamples in shipping container; 5 t (c n" 7. Sample holding times exceeded?

Yes [] No.8. Samples have:~tepe-hazard labels'custody seats ...appropriate -sample labels 9. Samples are.-0n good co,,dition -leaking-haye air bubbl.s 10. Were any anomalies identif .- YesJ[ ] No 11. .Description of anomalies.(include sample numbers): Sanilek Custodian/Laboratory:

/A .-a e /~Telephoned to:__________________" -Page 28 of 105 oSAMPLE RECEIPT & REVIEW FORM PMuse anly Client:SDG/ARCOCIWork Order: tG7832. /, 1-&5-0 Date Received:

A Rev- io.-coflisi m-e mresolved prior to sigaiag): Received BY: C I cdrk Sample Receipt Criteria [ Comments/Qualimers (Required for Non-Coaforming items)Shipping containers received intact ircle Applicable:

seals btokcn damaged conzainer inaking oie (describe)

I and s caled ? ICE;; ...Samples requiring cold Circle Coolan# ice bags blue ie dry ie Q!( odiu describe)2 preservation within (4 +/- 2 C)?Record preservation method. .....Chain of custody documents CO U S c included with Sample containers intact and dim sa tmqka danged container leaking continer e Od)C (dc ,,/sealed? bu.'* e. baO(A "W /. OX _,l p'~ ~Samples requiring chemical mple ID's. containers S a: preservation at proper pH? ,r, VOA vials free of headspace Sam& ID's and coamin affected: (defined as < 6mn bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory)

.. ..8 Samples received within holding id's and wte affected: time?9 Sample ID's on COC match ID's Suiple ID's and comainers affected: on bottles? I Date & time on COC match date SampIe WS UffeCte:& time on bottles? , _, Number of containers received I'S afect: match number indicated on COC?COC form is properly signed in LU C3VU Cd'L vL~Ac relinquished/received sections?___

Air Bill ,Tracking

  1. 's, & .

() 3 1L.&L" Additional Comments C V V iRSO RAD Receipt_#* *If > x2 area background is observed on samples identified as "non-Sregulated/non-radioactive, contact the Radiation Safety group for further__investigation.

A jRadiological Classification?

Maximum Counts Observed':

P Rcgulated?

Comments: jShippe -a I Hazardous NC [Material?

If yes, contact Waste I Hazard Class Shipped:_Manager or ESH Manager. UN#PM (or PMA) review of Hazard classitication:

Initials ,, ý , Date: 7(71 .10 rage 2-9 of 10U a 1. --,1 M 9 SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM VAAlk 16,7- 9-3 2, 1 ( , Z 95-0-Fid F Y--Fa co)- O-W "41= f:

__ q__ q_ _ COLO)?) no OOas 0"n 0e053A--- -- UoII &OOto -0(35 H [o ) -- -(lo,5S 550 ( o ) iv.-~ok -op 3-i (q0 lVL 5fr codce-i h ad m_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _b-s~ed .'J~CrL4~ro a iL U i1 _ _ _ _ _ _ _Page 30 of 105'I '" P Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major 0 Chain of Custody Form No. 2006-00367 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556

.. .... .. ..Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones W 4 4 Priority:

2] 30 D. [] 14 D. 0 7 D. Container Sample Size-Sample Designation Date Time Type &Type Comment, Preservation Lab Sample ID SamleDeigatin at Tme Code Code Code II 9106-0008-001F 5/05/06 11:13 SE C BP X X x Transferred from COC # 2006-00324 9106-0008-003F 5/5/06 13:35 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-004F 5/5/06 13:51 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-005F 5/5/06 14:17 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-006F 5/5/06 14:36 SE C BP x x x Transferred from COC # 2006-00325 9106-0008-006FS 5/5/06 14:36 SE C BP X X X " Transferred from COC # 2006-00325 9106-0008-007F 5/5/06 15:03 SE C BP X Transferred from COC # 2006-00325 9106-0008-002F 5/5/06 13:10 SE C BP X x x Transferred from COC # 2006-00325 4 i-f------------~-t-t-t-t I NOTES: PO #: 002332 MSR #: 06- 07'"3 SSWP# NA SLTP QA El Radwaste QA E] Non QA 1) elinqu Qhe Date/Time

2) , ived " ate/Time 3) Winquished By \ Date/Time
4) Redeive y V '"/ Ibate/Time Samples Shipped Via: F Fed Ex EUPS L]Hand El Other Bill of Lading #Rfl2? 5541//(2_Internal Container Temp.: __ Deg. C Custody Sealed?Yo NO Custody Seal Intact?YO NO Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major HeathPhyic Prceur GP-GGR-5 0400-Atacmet BCYO0 Mjo Chain of Custody Form o Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556

--. ..Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 Q 843 556 8171. Attn. Cheryl Jones z Priority:

0 30 D. [] 14 D. ED 7 D, Container Sample Size-Media Type &Type '" Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0008-008F 5/08/06 08:01 SE C BP x x x Transferred from COC # 2006-00327 010 9106-0008-009F 5/08/06 08:32 SE C BP x x x Transferred from COC # 2006-00327 Oil 9106-0008-OIOF 5/08/06 09:09 SE C BP X x x Transferred from COC # 2006-00327 1l 9106-0008-01OFS 5/08/06 09:09 SE C BP X X X Transferred from COC # 2006-00327)I 9106-0008-01IF 5/08/06 09:30 SE C BP x x x Transferred from COC # 2006-00327 10 9106-0008-012F 5/08/06 09:53 SE C BP X Transferred from COC # 2006-00327

)1 9106-0008-013F 5/08/06 10:16 SE C BP X x X Transferred from COC # 2006-00327 9106-0008-014F 5/08/06 110:47 SE C BP X x x Transferred from COC # 2006-00327 9106-0008-01F 5/08/06 1047 SE C BP, X ___________

NOTES: PO #: 002332 MSR #: 06-61q3 SSWP#NA SLTP QA fl Radwaste QA El Non QA Samples Shipped Via: CK Fed Ex l] UPS l Hand Ul Other Bill of Lading #Internal Container Temp.: -4 1 Deg. C Custody Sealed?YCD N)T Custody Seal Intact?1) Relinquished By Date/Time

2) Received By Date/Time S-iqs5/2ti4)(0 By bt 3) Relinquished By Date/Time
4) Received By Date/Time Yli7ND j~,~7L~1 ~/Connecticut Yankee Sta~tement of Work for Analytical Lab Services-CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:

4OQ u Cpto C SDG#: Work Order Number: Shipping CcitainerlD:*'q~r 6 t I J Chain ofCstody#

')OO..DuO&3(ofl

1. Custody Seals owi shipping container intact? -Yes ['rNo I I 2. Custody Seals dated and signed? Yes* [ No [<3. Chain-of-Custody record present? Yes C.00o I I 4. Cooler temperature
5. Vermiculite/packing materials is: Wet [ , Dry A",] /AIi 6" Number of samples in shipping container:

".;7. Sample holding times exceeded?

Yes [] No [4'8. Samples have:-thazard labels_ _custodly seals _/appropriate sample labels 9. Samples are:' -*/"'in. good co~ndton leking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ No 11.,. .Description of anomalies. (include sample numbers): Telephoned to:__ _ By on___.__*__

"..._.._,._

-_Page 33 of 105

  • SAMPLE RECEIPT & REVIEW FORM ber of contimners received i number indicated on COC?form is properly signed in I S::W --O RAD R=cipt I> x2 am background is observed on samples idenmiied as non--ilated/non-radiactive', contact the Radiation Saty, group for further Observed*:

no tv-ý -p 7a, kl[azard Class Shipped: NI: Initials I2& 26 Date:-7--Page 34 of 105 0 SAMPLE RECEIPT & REVIEW FORM.r PM urn oly SClient: Y an keSIDG/ARCOC/Work Order: Ap37 / /.Date Received:

1W ,PM(A) Review (ensure noncounrorming iteus are resoved prior to signing): Received By: C fui6k 1.I Sample Receipt Criteria CommentslQualiflers (Required for Non-Confonming Items)Shipping containers received intact Circle Applicable:

s-als brken damaged container leaking container other (describe) and sealed? __Samples requiring cold Circle Cooant # ice bags blue ice dry ice odief describe)2 preservation within (4 +/- 2 C)?Record preservation method. .21 'Chain of custody documents included with shipment?Sample containers intact and Circle Applicable:

seals broken damaged conairner leaking continer other (describe) sealed? __ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _Samples requiring chemical Sample ID's. containers affected and observed pH: preservation at proper pH?VOA vials free of headspace Sample ID's and containers affected: 6 (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to VOA laboratory) 1 8 Samples received within holding Id's a sew afected;time? V'SSample ID's on COG match ID's samPle ID's ani cotiners affected: on bottles? __10 Date & time on COC match date Smtuple ID's affected:& time on bottles?Number of containers received Sample ID's affected: match number indicated on COC?COC form is properly signed in j " I relinquished/received sections?14Air Bill ,Tracking

  1. 's, & "e o r1 Lace Additional Comments T RSO RAD Receipt #'4 ti *If > x2 area background is observed on samples i&dmfied as "nan-Suspected Hazard Information 0 r3 ca ,4 VD 2p regulated/non-radioactive*.

contact the Radiation Safety group for fiurther 1% , in ves tigati on .A I KaG oiogIC2i CLassltcation?

p.-¶ I1*~B PCB Regulated?

[Shipped as DOI Hazardous CMaterial?

If yes, contact Waste L I Manager or ESH Manager.jMaximum Counts Observed*:

V; CyPH-i Comments: Hazard Class Shipped: n U ND: PM (or PMA) review of Hazard classification:

Page 35 of 105 Ito3 7q IV Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received:

t,(. (¢ Og"b SDG#: Work Order Number: Shipping Cctntainer ID: -79 2 5 <4 I I 7 Chain of Custody # " Q U4C, I. Custody Seals o0 shipping container intact?. Yes j"'o 2. Custody Seals dated and signed? Yes L o [ -3. Chai;k-of-Custody record present? Yes [,4o [1 4. Cooler temperature

.ZI'5. Vermiculite/packing materials is: Wet ý,,]ry []6' Number of samples in shipping container:

(9 t 1 h k'7. Sample holding times exceeded?

Yes.[ ] No 8. Samples have: t.pe -hazard labels.cuStody seals -_appropriate sample labels 9. Samples are:.Jin good condition leaking-broken .have air bubbles 10.11.Were any anomalies identified in sample receipt?Description of anomalies (include sample numbers): Yes []No OW Sample. Custodian/Laboratory:

e C" b Date:. -Y -, Telephoned to: On By Page 36 of 105.. 'r11.

Health Physics Procedure/.tj gvo J GPP-GGGR-R5104

-00 3 -Attach rnen t B-CY-001 Major Helt Pyic PoedreIJJ

~4 GPGGR-5 0-03 Atahmn BCY0 IMao CD Chain of Custody Form No. 2006-00380 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424: Project Name: Haddam Neck Decommissioning Analyses Requested -abUse Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones C/_ Z Priority:

Z 30 D.E] 14 D. E 7 D. Container Sample Size-Media Type &Type C P Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID ,i 9106-0009-016F 5/15/06 13:28 SE C BP x x Transferred from COC 2006-00352 502.9106-0009-016FS 5/15/06 13:28 SE C BP x x Transferred from COC 2006-00352 9106-0009-017F 5/15/06 14:03 SE C BP X x Transferred from COC 2006-00352 9106-0009-01IF 5/15/06 08:05 SE C BP x Transferred from COC 2006-00351 p 9106-0009-013F 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 9106-0009-013FS 5/15/06 08:35 SE C BP X x Transferred from COC 2006-00351 DII 9106-0009-014F 5/15/06 08:59 SE C BP x Transferred from COC 2006-00351 9106-0009-015F 5/15/06 09:36 SE C BP X X Transferred from COC 2006-00351 i i i- P i 4- -----------

i I 1. J A L L ~NOTES: PO#: 002332 MSR#: 06-0/S SSWP#NA Z LTPQA LI Radwaste QA tL_. Non QA 1) Relinquised By 3) Relinquished By Date/Time j2) Re-~~= V- LyI- -Date/Time r-16-06 9O 0 Samples Shipped Via:[ Fed Ex El uPs Hl Hand El Other Bill of Lading #Internal Container Temp.: ___ Deg. C Custody Sealed?YO NI Custody Seal Intact?Y []7 N 7 Date/Time I 4) Reeivet By I Date/Time I Health Physics Procedure I/ /"Irf GPP-GGGR-R5104-003 -Attachment B-CY-001 Major-I --- I 00 00 Ott oil-Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00381 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC, 29407 .843 556 8171. Attn. Cheryl Jones r, , Z Priority:

30 D. [] 14 D. [17 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0009-OO1F 5/11/06 13:22 SE C BP X X Transferred from COC 2006-00347 9106-0009-002F 5/11/06 13:46 SE C BP X X Transferred from COC 2006-00347 9106-0009-003F 5/11/06 14:06 SE C BP X X Transferred from COC 2006-00347 9106-0009-004F 5/11/06 14:30 SE C BP X X Transferred from COC 2006-00347 9106-0009-005F 5/11/06 14:55 SE C BP X X Transferred from COC 2006-00347 9106-0009-007F 5/12/06 07:44 SE C BP X X Transferred from COC 2006-00348 9106-0009-008F 5/12/06 08:16 SE C BP X x Transferred from COC 2006-00348 9106-0009-009F 5/12/06 08:35 SE C BP X X Transferred from COC 2006-00348 9106-0009-OIOF 5/12/06 09:07 SE C BP X X Transferred from COC 2006-00348 NOTES: PO #: 002332 MSR #: 06-SSWP# NA E LTP QA [] Radwaste QA 0l Non QA 1) Relinquished By Date/Time

2) Rec* ed y Date/Time 3) Relinquished By Date/Time
4) Receivedby Date/Time Samples Shipped Via:[ Fed Ex~UPS 0 Hand-] Other Bill of Lading #::tqzf /N/ zy2"2x Internal Container Temp.: _ Deg. C Custody Sealed?YO NO Custody Seal Intact?Y 0 ND Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-001 Figure 1. Sample Check-in List Datefrime Received:

(2 -0 00 "0 SDG#: rL- ,-o .0 o X Work Order Number: Shipping C'tainer IDI, Chain of Custody# "CM O -12, Cctntaincr ID: °' -/'1. Custody Seals. oti shipping container intact? -Yes D4] No [2. Custody Seals dated and signed? Yes [ .No 3. Chain-of-Custody record present? Yes f No [].4. Cooler temperature i0 ,, "6 5. Vermiculite/packing materials is: Wet [] Dry 6. Number of samples in shipping container:

....__7. Sample holding times exceeded?

Yes No []8. Samples have: tape _____hazard labels X _custody seals -.__appropriate sample labels 9. Samples are:-,A-in good condition

.leaking-broken --have air bubbles 10. Were any anomalies identified in sample receipt? Yes [' No-II *..Description of anomalies (include sample numbers):

..Sample Custodian/Laboratory:-

Date.: 06 6 , 'Telephoned to: On By " Page 39 of 105 Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Chain of Custody Form No. 2006-00349 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments: Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 , V) " 843 556 8171. Attn. Cheryl Jones rn d z Priority:

Z 30 D. E 14 D. [] 7 D. Container media Type &Type Sample Desigation Date Time Code Code Code Comment, Preservation Lab Sample ID a 9106-0010-OOIF 5/04/06 10:49 SE C BP X X Transferred from COC 2006-00321 0 9106-0010-002F 5/04/06 11:12 SE C BP X X Transferred from COC 2006-00321 1 t 9106-0010-004F 5/04/06 12:48 SE C BP X X Transferred from COC 2006-00321 9106-0010-006F 5/04/06 13:34 SE C BP X x Transferred from COC 2006-00321 9106-0010-007F 5/04/06 13:21 SE C BP X X Transferred from COC 2006-00321

-9106-0010-009F 5/04/06 14:01 SE C BP X X Traferred from COC 2006-00321 9106-0010-00F 5/04/06 14:21 SE C BP X X Transferred from COC 2006-00321 J;J 9106-0010-012F 5/04/06 14:44 SE C BP X X Transferred from COC 2006-00321 9106-0010-013F 5/04/06 15:06 SE C BP X Transferred from COC 2006-00321 0 0 b e-o II NOTES: PO #: 002332 MSR#: 06- 0707 SSWP#NA 9 LTP QA[] Radwaste QA El Non QA 1) RelinquisheoBy Date/Ti e 2) Received y Date/Time 1) Relinquished By Datefime 4) Received By Date/Time Samples Shipped Via:[ Fed Ex EUPS El Hand El Other Bill of Lading -3 q04- 3 1 internal Container Temp.: /7Deg. C CustodyySealed?

Custody Seal Intact?Y Q- o Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O0L Figure 1. Sample Check-in List Date/Time Received:

q qf" 5"/ °6 *o SDG#: M1V_ ... n 1r-0707 2 Work Order Number: Shipping Cdntainer ID: ,O1 311) 55 ?. Chain of Custody # 60 39 .1. Custody Seals ori shipping container intact? -Yes I)(1 No [ ]2. Custody Seals dated and signed? Yes [] No []3. Chain-of-Custody record present? Yes D] No [ ]4. Cooler temperature

'7 9 C 5. Vermiculite/packing materials is: Wet ] Dry t\ I 6. Number of samples in shipping container:

___7. Sample holding times exceeded?

Yes I3 No 8. Samples have:-tape -hazard labels.-.custody seals -appropriate sample labels 9. Samples are: 4_._in good condition

.1jleaking-broken -have air bubbles 10. Were any anomalies identified in sample receipt? Yes [ ] No j 11. -Description of anomalies (include sample numbers): Sample CustodianjLaboratoxy:

Date: )6 -3_--O G Telephoned to: On By " Page 41 of 105 SAMPLE RECEIPT & REVIEW FORM 00ýP1roRV&t" PM use only Client: ad-At, 44 ------- SDG/ARCCWok Order: Date Received:

5- PM(A) Review ( 0 o g items are resolved prior to signing): Received By: Sample Receipt Criteria .Com ents/Quaiiers (Required for Non-Conforming Items)Shipping containers received intact Circle Applicable:

seals broken damaged container leaking container other (describe) 1and sealed? Z Samples requiring cold Circle Coolant # ice bags blue ice dry ice jiie.) other describe)2 preservation within (4 +/- 2 C)? V/Record preservation method.3Chain of custody documents included with shipment?4 Sample containers intact and C Circle Applicable:

seals broken damaged container leaking container other (describe) sealed? -'/5 Samples requiring chemical Sample ID's. containers affected and observed pH:_ reservation at proper pH? .....6 VOA vials free of headspace Sample ID's and containers affected: (defined as < 6mm bubble)?Are Encore containers present?7 (If yes, immediately deliver to-VOA laboratory)

_________________________

8 Samples received within holding Id's and tests affected: 8 time? IA Sample ID's on COC match ID's Sample ID's and containers affected: on bottles?10 Date & time on COC match date Sample ID's affected:& time on bottles? ___11 Number of containers received Sample ID's affected: match number indicated on COC?12 COC form is properly signed in relinquished/received sections?Air Bill ,Tracking

  1. 's, &1Additional Comments CI V I RSO RAD Receipt #S*If H= => x2 area background is observed on samples identified as "non-Sup e H d Iregulated/non-radioactive", contact the Radiation Safety group for further___________________4_

1 i investigation.

A Radiological Classification?

Maximum Counts Observed*:

  • P'B Regulated?

V Comments: fShpped as DOI Hazardous* Material?

If yes, contact Waste Hazard Class Shipped: Manager or ESH Manager.I N#: PM (or PMA) review of Hazard classification:

Initials Date: Z Z Page 42 of 105 List of current GEL Certifications as of 15 August 2006 E State Alaska Arizona Arkansas-: -CLIA California Colorado Connecticut Dept. of Navy EPA Florida/NELAP Georgia Idaho Illinois Indiana Kansas--Kentucky Maryland Massachusetts Michigan Nevada New Jersey New York North Carolina North Carolina Drinking W North Dakota Oklahoma Pennsylvania-South Carolina Tennessee Texas U.S. Dept. of Agriculture US Army Corps of Engineer Utah Vermont Virginia Washington Certification UST-062 AZ0668 88-0651.42D0904046 0115 ICA -GenEngLabs PH-0169 NFESC 413 WG-1I5J E.87156 E87156 (FLINELAP)

N/A 200029 C-SC-01 E- 10332 90129 270 M-S1CO2 9903-_ ----_Z--.--- _-5-b SC002 233 45709 R-158 9904 68-485 10120001/10585001/10120002 02934 TX213-2006A S-52597 N/A 8037697376 GEL N/A 00151 C223-H---.1~~~~1 Page 43 of 105 RADIOLOGICAL ANALYSIS Page 44 of 105 Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)Work Order 168404 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555696 554650 554649 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404011 168404012 168404013 168404014 168404015 1201153129 1201153130 1201153131 1201153132 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-OO1F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Page 45 of 105 Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 168404003 (9106-0003-004F) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Page 46 of 105 Product: Alphaspec Am241, Cm, Solid ALL FSS DOE EML HASL-300, Am-05-RC Modified Analytical Method: Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 557837 554650 554649 Sample ID 168404009 168404010 1201158316 1201158317 1201158318 1201158319 Client ID 9106-0006-005F 9106-0008-006F Method Blank (MB)168404009(9106-0006-005F)

Sample Duplicate (DUP)168404009(9106-0006-005F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 I REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168404009 (9106-0006-005F).

QC Information Page 47 of 105 All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555697 554650 554649 Page 48 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201153133 1201153134 1201153135 1201153136 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Page 49 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- I1-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555698 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 50 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201153137 1201153138 1201153139 1201153140 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Page 51 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Manual Integration No manual integrations were performed on data in this batch.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 556350 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 52 of 105 Sample ID 168404003 168404004 168404012 168404013 168404014 168404015 1201154644 1201154645 1201154646 1201154647 Client ID 9106-0003-004F 9106-0003-015F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168404003(9106-0003-004F)

Sample Duplicate (DUP)168404003(9106-0003-004F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Page 53 of 105 Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Samples 1201154644 (MB), 1201154645 (9106-0003-004F), 1201154646 (9106-0003-004F), 1201154647 (LCS), 168404003 (9106-0003-004F), 168404004 (9106-0003-015F), 168404012 (9106-0009-002F), 168404013 (9106-0009-017F), 168404014 (9106-0010-001F) and 168404015 (9106-0010-012F) were dried and reweighed due to low matrix spike/laboratory control sample recovery.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 554580 Page 54 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201150561 1201150562 1201150563 1201150564 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-OO1F 9106-0010-012F Method Blank (MB)168340012(9304-02-003C)

Sample Duplicate (DUP)168340012(9304-02-003C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.Page 55 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555722 554650 554649 Page 56 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201153222 1201153223 1201153224 1201153225 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-OO1F 9106-0010-012F Method Blank (MB)168340012(9304-02-003C)

Sample Duplicate (DUP)168340012(9304-02-003C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.Page 57 of 105 Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: Prep Method: DOE RESL Ni-1, Modified Dry Soil Prep GL-RAD-A-021 Method: Analytical Batch Number: Prep Batch Number: Dry Soil Prep GL-RAD-A-021 Batch Number: Ash Soil Prep Dry Soil Prep 555723 554650 554649 Page 58 of 105 Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 1201153226 1201153227 1201153228 1201153229 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F Method Blank (MB)168340012(9304-02-003C)

Sample Duplicate (DUP)168340012(9304-02-003C)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.Calibration Information: ,Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340012 (9304-02-003C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Page 59 of 105 Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Analytical Method: Analytical Batch Number: Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201150569 1201150570 1201150571 1201150572 LSC, Tritium Dist, Solid-HTD2,ALL FSS EPA 906.0 Modified 554582 Client ID 9106-0002-007F 9106-0002-01 IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-01OF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-OO1F 9106-0010-012F Method Blank (MB)168340011(9304-01-005C)

Sample Duplicate (DUP)168340011(9304-01-005C)

Matrix Spike (MS)Laboratory Control Sample (LCS)Page 60 of 105 SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QCQ Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168340011 (9304-01-005C).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis Sample 168404010 (9106-0008-006F) was recounted due to high MDA.Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Page 61 of 105 Qualifier information Manual qualifiers were not required.Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: Analytical Batch Number: Sample ID 168404001 168404002 168404003 168404004 168404005 168404006 168404007 168404008 168404009 168404010 168404011 168404012 168404013 168404014 168404015 1201150573 1201150574 1201150575 1201150576 EPA EERF C-01 Modified 554583 Client ID 9106-0002-007F 9106-0002-01IF 9106-0003-004F 9106-0003-015F 9106-0004-005F 9106-0004-015F 9106-0005-OIOF 9106-0005-014F 9106-0006-005F 9106-0008-006F 9106-0008-008F 9106-0009-002F 9106-0009-017F 9106-0010-001F 9106-0010-012F Method Blank (MB)168404003(9106-0003-004F)

Sample Duplicate (DUP)168404003(9106-0003-004F)

Matrix Spike (MS)Laboratory Control Sample (LCS)SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).Page 62 of 105 Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (0Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).

QC Information All of the QC samples met the required acceptance limits.Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.Preparation Information All preparation criteria have been met for these analyses.Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents.

A nonconformance report (NCR) was not generated for this SDG.Additional Comments Additional comments were not required for this sample set.Qualifier information Manual qualifiers were not required.Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator.

In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.Page 63 of 105 The following data validator verified the information presented in this case narrative:

Reviewer/Date:

(& 1§46e% e46 Page 64 of 105 SAMPLE DATA

SUMMARY

Page 65 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.Client SDG: 168404 GEL Work Order: 168404 The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria** Analyte is a surrogate compound U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.ND The analyte concentration is not detected above the detection limit.The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures.

Please direct any questions to your Project Manager, Cheryl Jones.Reviewed by Page 66 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0002-007F 168404001 SE 18-MAY-06 02-JUN-06 Client 20.9%Project: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0762 Curium-242 U 0.00 Curium-243/244 U -0.00853 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.199 Plutonium-239/240 U 0.0341 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 10.0 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.17 Liquid Scint C14, SolidAlLFSS Carbon-14 U 0.0813 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 9.90 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.02 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.139+/-0.102+/-0.0995+/-0.0717 0.00 0.00 0.0405+/-0.102+/-0.0995+/-0.0717 0.0956 0.138 0.177 0.444 0.323 10.7 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g+/-0.228 0.181 +/-0.229+/-0.129 0.120 +/-0.129+/-6.64 5.08 +/-6.72+/-6.67 5.28 +/-6.67+/-0.0797 0.0634 +/-0.0797+/-48.1 32.0 +/-48.1+/-6.39 5.18 +/-6.40+/-0.213 0.173 +/-0.213 BXLI 08/11/06 1336 555696 1 BXLI 08/11/06 1633 555697 2 BXL1 08/16/06 1220 555698 3 DFA1 08/09/06 1128 554582 4 ATH2 08/09/06 0324 554583 5 MXPI 08/12/06 1633 555722 6 MXPI 08/11/06 0738 555723 7 EGD1 08/11/06 2027 554580 8 11.4 pCi/g 0.132 65.9 pCi/g pCi/g 10.6 pCi/g 0.360 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300.

Am-05-RC Modified 2 3 4 DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified Page 67 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0002-007F 168404001 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 6 7 8 EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%80 100 98 75 76 74 Acceptable Limits (15%-125%)

(15%-125%)

(25%-125%)

(15%-125%)

(25%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 68 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.120 Curium-242 U -0.0146 Curium-243/244 U -0.0103 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0121 Plutonium-239/240 U 0.0254 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.72 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -0.521 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.023 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 3.93 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.52 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.173 9106-0002-01 IF 168404002 SE 19-MAY-06 02-JUN-06 Client 17.4%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+/-0.154+/-0.122+/-0.0861 0.0683 0.0692 0.0487+/-0.155+/-0.123+/-0.0862+/-0.125 0.127 +/-0.125+/-0.0675 0.0381 +/-0.0675+/-7.02 5.56 +/-7.05+/-7.03 5.94 +/-7.03+/-0.0828 0.0685 +/-0.0828+/-47.7 31.9 +/-47.7+/-5.81 4.68 +/-5.81+/-0.203 0.164 +/-0.203 0.251 0.303 0.213 0.344 0.167 11.7 12.8 0.143 65.7 9.60 0.341 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1336 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1237 555698 3 DFA1 08/09/06 1143 554582 4 ATH2 08/09/06 0426 554583 5 MXPI 08/12/06 1649 555722 6 MXPI 08/11/06 0825 555723 7 EGD1 08/11/06 2043 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified Page 69 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0002-01IF 168404002 Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 8 DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 76 100 88 72 76 79 (15%-125%)

(15%-125%)

(25%-6125%)

(15%-/125%)

(25%-125%)

(15/-,125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 70 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Project: YANK01204 Client ID: YANKOO Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.027 Curium-242 U 0.112 Curium-243/244 U 0.0217 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.061 Plutonium-239/240 U 0.0551 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.00343 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid HTD2,ALL FSS Tritium U 0.603 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0937 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 7.68 Liquid Scint Ni63, Solid ALL FSS Nickel-63 U 5.74 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0643 The following Prep Methods were performed 9106-0003-004F 168404003 SE 25-APR-06 05-MAY-06 Client 23.5%LC TPU Uncertainty

+/-0.117+/-0.315+/-0.206+/-0.189+/-0.103+/-5.73 0.153 0.245 0.205 0.176 0.0584 4.40+/-0.117+1-0.315+/-0.206+/-0.189+/-0.103+/-5.78 MDA 0.488 0.781 0.594 0.449 0.215 9.25 0.036 14.8 0.134 70.4 13.6 0.351 Units DF Analyst Date Time Batch Mtd+/-0.0203 0.0172 +/-0.0203 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/13/06 0819 555696 1 BXL1 08/11/06 1633 555697 2 BXLI 08/16/06 1253 555698 3 BXFI 08/14/06 0834 556350 4+/-8.25+/-0.0813+/-51.2+/-7.12+/-0.198 6.87 0.0642 34.2 6.58 0.169+/-8.25+/-0.0813+/-51.2+/-7.13+/-0.198 DFAI ATH2 MXPI MXP1 EGD1 08/09/06 1159 554582 08/09/06 0529 554583 08/12/06 1706 555722 08/11/06 0912 555723 08/11/06 2059 554580 5 6 7 8 9 Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-l1 -RC Modified Page 71 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Cprtifir-tit nf Ann]vsie J-Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-004F 168404003 Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter 3 4 5 6 7 8 9 Qualifier Result Uncertainty DOE EML HASL-300, Pu-I 1-RC Modified EPA 905.0 Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Test Recovery%

Acceptable Limits Alphaspec Am241, Cm, Solid ALl Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 42 92 113 59 71 83 76 (15%/o-125%)

(15%-125%)

(25%-/125%)

(25%-125%)

(15%-125%)

(25%-.125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.U! Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 72 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Client Sample ID: Sample ID: 9106-0003-004F 168404003 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.Page 73 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0003-015F 168404004 SE 25-APR-06 05-MAY-06 Client 22.5%Project: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0456 Curium-242 U 0.113 Curium-243/244 U 0.180 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0196 Plutonium-239/240 U 0.0326 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.63 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.00477 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 1.03 Liquid Scint C14, SolidAllFSS Carbon-14 0.156 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -9.99 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.939 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.237 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+1-0.155+/-0.181+/-0.239+/-0.121+/-0.0639+/-6.19 0.139 0.0733 0.181 0.118 0.00 4.86+/-0.155+/-0.182+/-0.240+/-0.121+/-0.064+/-6.22+/-0.0216 0.0179 +/-0.0216 0.387 0.321 0.472 0.324 0.0884 10.2 0.0375 12.6 0.146 59.2 21.6 0.353 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXL1 08/11/06 1633 555697 2 BXLI 08/16/06 1309 555698 3 BXF1 08/14/06 0834 556350 4+/-7.06+/-0.0912+/-42.7+/-10.1+/-0.213 5.85 0.0699 28.7 10.3 0.170+/-7.06+/-0.0913+/-42.7+/-10.1+/-0.213 DFA1 ATH2 MXP I MXPI EGDI 08/09/06 1215 554582 08/09/06 0632 554583 08/12/06 1722 555722 08/11/06 1001 555723 08/11/06 2115 554580 5 6 7 8 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified Page 74 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-015F 168404004 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 4 5 6 7 8 9 DOE EML HASL-300, Pu-I 1-RC Modified EPA 905.0 Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýGFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%78 94 101 58 75 62 75 Acceptable Limits (15%-I125%)

(15%-125%)

(25%-125%)

(25%-I125%)

(15%-125%)

(25%- 125%o)(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding.time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 75 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0003-015F 168404004 Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.Page 76 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0004-005F 168404005 SE 03-MAY-06 12-MAY-06 Client 15.4%Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier R Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -(Curium-242 U -0.Curium-243/244 U -0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.Plutonium-239/240 U -0.Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U (Liquid Scint C14, Solid All,FSS Carbon-14 (Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.esult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.036 0169 0129 0217 0708 9.52).854 1.347-1.57 6.39 0198+/-0.123+/-0.033+/-0.227+/-0.163+/-0.0791+/-6.00+/-5.88+/-0.097+/-46.0+/-7.62+/-0.187 0.157 0.080 0.247 0.181 0.128 4.57 4.87 0.0674 30.7 7.40 0.156+/-0.123+/-0.0331+/-0.227+/-0.163+/-0.0795+/-6.07+/-5.88+/-0.0972+/-46.0+/-7.62+/-0.187 0.437 0.350 0.619 0.444 0.337 9.61 10.5 0.141 63.2 15.5 0.324 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1326 555698 3 DFAI ATH2 MXPI MXPI EGDI 08/09/06 1231 554582 08/09/06 0734 554583 08/12/06 1738 555722 08/11/06 1017 555723 08/11/06 2131 554580 4 5 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 77 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005F Project: YANK01204 Sample ID: 168404005 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 65 (15%-/125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 95 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 105 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 78 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 80 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 80 (15%- 125%)Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 78 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0004-015F 168404006 SE 03-MAY-06 12-MAY-06 Client 26.5%Proiect: YANK01204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Re Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.(Curium-242 U -0.(Curium-243/244 U -0.(Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.(Plutonium-239/240 U -0 Liquid Scint Pu24l, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAllFSS Carbon- 14 U 0.0 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0 suit Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 0823 0154)994 1466.142 6.64-2.9 1352 1.88 3.88 1894+/-0.203+/-0.0301+/-0.251+/-0.213+/-0.108+/-6.53+/-7.59+/-0.0868+/-46.8+/-7.46+/-0.198 0.178 0.0729 0.300 0.210 0.191 5.16 6.60 0.0713 31.3 7.40 0.163+/-0.203+/-0.0302+/-0.251+/-0.213+/-0.109+/-6.57+/-7.59+/-0.0868+/-46.8+/-7.46+/-0.198 0.469 0.319 0.713 0.521 0.483 10.8 14.2 0.149 64.4 15.5 0.338 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXL1 08/16/06 1342 555698 3 DFAI ATH2 MXP I MXPI EGD I 08/09/06 1247 554582 08/09/06 0837 554583 08/12/06 1754 555722 08/11/06 1033 555723 08/11/06 2147 554580 4 5 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-l l-RC Modified 3 DOE EML HASL-300, Pu-I 1-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 79 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0004-015F 168404006 Project: YANK01204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%72 72 94 73 80 78 Acceptable Limits (15%-125%)

(15%/-125%)

(25%-6125%)

(15%-125%)

(25%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 80 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0005-01OF 168404007 SE 02-MAY-06 09-MAY-06 Client 56.2%Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier R Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -(Curium-242 U -0.Curium-243/244 U -0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.Plutonium-239/240 U 0.Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAllFSS Carbon-14 U 0.Liquid Scint Fe55, Solid-ALL FSS Iron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -esult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 0.128 0115 0333 0548 0195 10.4 0.00 0636 36.1 7.26-0.05+/-0.0939+/-0.128+/-0.122+/-0.169+/-0.121+/-6.89+/-6.86+/-0.0801+/-44.1+/-10.2+/-0.199 0.142 0.147 0.149 0.158 0.117 5.27 5.76 0.0644 28.7 10.0 0.169+/-0.0942+/-0.128+/-0.122+/-0.170+/-0.121+/-6.97+/-6.86+/-0.0801+/-44.1+/-10.2+/-0.199 0.385 0.450 0.401 0.403 0.322 11.1 12.4 0.135 59.0 20.9 0.351 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXL1 08/16/06 1358 555698 3 DFAI ATH2 MXPI MXPI EGD1 08/09/06 1303 554582 08/09/06 1017 554583 08/12/06 1811 555722 08/11/06 1049 555723 08/11/06 2203 554580 4 5 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 81 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0005-010F 168404007 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%85 91 92 81 64 77 Acceptable Limits (15%-125%)

(.15%-125%)

(25%-125%)

(15%-125%)

(25%- 125%)(15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 82 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Report Date: August 21, 2006 9106-0005-014F 168404008 SE 02-MAY-06 09-MAY-06 Client 32.3%Proiect: YANKO 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier R Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0 Curium-242 U -Curium-243/244 U 0.Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.Plutonium-239/240 U -0.Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U Liquid Scint C14, SolidAllFSS Carbon-14 U 0.Liquid Scint Fe55, Solid-ALL FSS lron-55 U Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -(esult Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 0591-0.04 0634 0694 0287 4.68 6.02 0892 19.8 5.41).134+/-0.219+1-0.0554+/-0.261+/-0.106+/-0.098+/-8.01+/-6.38+/-0.0827+/-46.3+/-7.91+/-0.192 0.231 0.134 0.249 0.160 0.127 6.48 4.90 0.0655 30.6 7.77 0.167+/-0.219+/-0.0557+/-0.261+/-0.106+/-0.0981+/-8.02+/-6.38+/-0.0827+/-46.3+/-7.91+/-0.192 0.608 0.494 0.646 0.434 0.369 13.6 10.6 0.137 62.9 16.2 0.346 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXL1 08/11/06 1633 555697 2 BXLI 08/16/06 1415 555698 3 DFAI ATH2 MXPI MXPI EGD1 08/09/06 1319 554582 08/09/06 1424 554583 08/12/06 1827 555722 08/11/06 1106 555723 08/11/06 2218 554580 4 5 6 7 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu- I -RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 83 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0005-014F 168404008 Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 DOE RESL Fe-I, Modified DOE RESL Ni-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%50 61 74 76 76 75 Acceptable Limits (15%-125%)

(15%-125%)

(25%-I125%)

(15%-125%)

(25%--125%)

(15%-1125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 84 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0006-005F 168404009 SE 28-APR-06 12-MAY-06 Client 16.5%Project: Client ID: Vol. Recv.: YANK01204 YANKOOI Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.0851 Curium-242 U -0.0253 Curium-243/244 U -0.0479 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0183 Plutonium-239/240 U 0.00122 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.43 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -2.02 Liquid Scint C14, SolidAllFSS Carbon- 14 0.142 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 12.6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.70 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.00659+/-0.136+/-0.0495+/-0.0542 0.106 +/-0.136 0.120 +/-0.0496 0.131 +/-0.0545+/-0.113 0.110 +/-0.113+/-0.0662 0.0694 +/-0.0662+/-5.83 4.67 +/-5.85+/-6.67 5.76 +/-6.67+/-0.0798 0.061 +/-0.0799+/-47.6 31.7 +/-47.6+/-9.56 9.31 +/-9.56+/-0.185 0.156 +/-0.185 0.390 0.525 0.443 0.303 0.221 9.82 12.4 0.127 65.3 19.5 0.323 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/16/06 0949 557837 1 BXLI 08/11/06 1633 555697 3 BXLI 08/16/06 1431 555698 4 DFAI 08/09/06 1335 554582 5 ATH2 08/09/06 1719 554583 6 MXPI 08/12/06 1843 555722 7 MXPI 08/11/06 1122 555723 8 EGD1 08/11/06 2234 554580 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 3 4 5 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified Page 85 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0006-005F 168404009 Project: YANK0 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 7 8 9 EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE RESL Ni-1, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FýLiquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%76 93 105 72 64 81 Acceptable Limits (15%-125%)

(15%-125%)

(25%-125%)

(15%-t125%)

(25%/.-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 86 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0008-006F 168404010 SE 05-MAY-06 26-MAY-06 Client 34.8%Proiect: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.129 Curium-242 U 0.103 Curium-243/244 U -0.0161 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0276 Plutonium-239/240 U 0.00359 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 14.9 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 Liquid Scint C14, SolidAlFSS Carbon-14 U 0.107 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 15.1 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.258+/-0.195+/-0.202+/-0.0316 0.0758 0.00 0.0766+/-0.196+/-0.203+/-0.0317+/-0.0711 0.0967 +/-0.0712+/-0.113 0.118 +/-0.113+/-6.37 4.64 +/-6.51+/-6.06 5.09 +/-6.06+/-0.0846 0.0664 +/-0.0846+/-41.4 27.5 +/-41.4+/-0.225 0.179 +/-0.225 0.332 0.280 0.335 0.275 0.317 9.75 10.7 0.139 56.6 0.373 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 08/16/06 0949 557837 1 BXLI 08/11/06 1633 555697 3 BXLI 08/16/06 1447 555698 4 DFAI 08/10/06 2150 554582 5 ATH2 08/09/06 1822 554583 6 MXPI 08/12/06 1900 555722 7 EGDI 08/11/06 2251 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 6 7 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-I 1-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified Page 87 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0008-006F 168404010 Project: Client ID: Vol. Recv.: YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Recovery%Acceptable Limits Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 77 94 103 72 71 (15%-1I25%)

(15°/7-125%)

(25%-125%)

(15%-125%)

(15%-/125%)

Notes: The Qualifiers in this report are defined as follows* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 88 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: 9106-0008-008F Project: YANK01204 Sample ID: 168404011 Client ID: YANKOO0 Matrix: SE Vol. Recv.: Collect Date: 08-MAY-06 Receive Date: 26-MAY-06 Collector:

Client Moisture:

35.7%Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0969 Curium-242 U -0.0482 Curium-243/244 U -0.0576 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0397 Plutonium-239/240 U -0.0315 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 11.5 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 Liquid Scint C14, SolidAllFSS Carbon-14 U -0.0238 Liquid Scint Fe55, Solid-ALL FSS lron-55 U -10.7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0956+/-0.192+/-0.142+/-0.202 0.152 0.132 0.240+/-0.193+/-0.142+/-0.203+/-0.096 0.125 +/-0.096+/-0.114 0.137 +/-0.114+/-6.72 5.08 +/-6.80+/-5.92 4.97 +/-5.92+/-0.0745 0.0636 +/-0.0745+/-40.9 27.5 +/-40.9+/-0.211 0.174 +/-0.211 0.426 0.446 0.603 0.328 0.353 10.7 10.7 0.133 56.8 0.361 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 1633 555697 2 BXLI 08/16/06 1504 555698 3 DFAI 08/09/06 1407 554582 4 ATH2 08/09/06 1924 554583 5 MXPI 08/12/06 1916 555722 6 EGDI 08/11/06 2307 554580 7 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 5 6 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-1 I-RC Modified DOE EML HASL-300, Pu-I I-RC Modified EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified Page 89 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0008-008F 168404011 Project: Client ID: Vol. Recv.: YANK01204 YANKOO I Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 7 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%65 98 96 76 74 Acceptable Limits (15%-I125%)

(15%-125%)

(25%-125%)

(15%-.125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 90 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd Contact: Project: East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.00144 Curium-242 U 0.0192 Curium-243/244 U 0.013 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00587 Plutonium-239/240 U 0.0186 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.6 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U 0.0151 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.12 Liquid Scint C14, Solid Al1, FSS Carbon- 14 U 0.046 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 12.9 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.078 9106-0009-002F 168404012 SE 11-MAY-06 08-JUN-06 Client 33%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd+1-0.155+/-0.145+/-0.268 0.166 +/-0.155 0.135 +/-0.145 0.281 +/-0.268+/-0.0493 0.0279 +/-0.0494+/-0.0492 0.0278 +/-0.0493+/-6.90 5.13 +/-7.01+/-0.0146 0.0114 +/-0.0146+/-8.36 6.70 +/-8.36+/-0.0755 0.0613 +/-0.0755+/-40.6 26.8 +/-40.6+/-0.203 0.168 +/-0.203 0.458 0.455 0.687 0.122 0.122 10.8 0.0242 14.5 0.128 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXL1 08/11/06 1632 555697 2 BXLI 08/16/06 1520 555698 3 BXFI 08/14/06 0834 556350 4 DFAI 08/09/06 1422 554582 5 ATH2 08/09/06 2027 554583 6 MXPI 08/12/06 1932 555722 7 EGDI 08/11/06 2323 554580 8 55.2 pCi/g 0.348 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 3 4 DOE EML HASL-300, Pu-I 1-RC Modified DOE EML HASL-300, Pu- 11-RC Modified EPA 905.0 Modified Page 91 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: 9106-0009-002F 168404012 Project: YANK0 1204 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 6 7 8 EPA 906.0 Modified EPA EERF C-01 Modified DOE RESL Fe-I, Modified DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Americium-243 Plutonium-242 Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Carrier/Tracer Recovery Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Recovery%61 98 94 69 81 75 Acceptable Limits (15%-125%)

(15%-125%)

(25%-/125%)

(25%-/125%)

(15%-125%)

(15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 92 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0009-017F 168404013 SE 15-MAY-06 08-JUN-06 Client 28.4%Project: Client ID: Vol. Recv.: YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U Curium-242 U Curium-243/244 U Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -Plutonium-239/240 U Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U Rad Liquid Scintillation Analysis 0.0755 0.0957-0.073 0.00629 0.0262+/-0.242+/-0.220+/-0.214 0.230 +/-0.243 0.171 +/-0.220 0.256 +/-0.214+/-0.0529 0.0299 +/-0.0529+/-0.0513 0.00 +/-0.0514 13.3 +/-6.66 4.95 +/-6.77 0.0205 +/-0.0151 0.0116 +1-0.0151 0.574 0.509 0.627 0.131 0.0709 10.4 0.0246 14.4 0.131 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 08/11/06 1434 555696 1 BXL1 08/11/06 1632 555697 2 BXLI 08/16/06 1536 555698 3 BXFI 08/14/06 0833 556350 4 DFAI 08/09/06 1438 554582 5 ATH2 08/09/06 2129 554583 6 MXPI 08/12/06 1949 555722 7 EGDI 08/11/06 2338 554580 8 LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.583 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0271 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -61.9 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0628 The following Prep Methods were performed Method Description

+/-7.98 6.65 +/-7.98+/-0.0759 0.0625 +/-0.0759+1-150 102 +/-150+/-0.200 0.165 +/-0.200 210 pCi/g 0.343 pCi/g Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 3 4 DOE EML HASL-300, Pu- 11-RC Modified DOE EML HASL-300, Pu-l I-RC Modified EPA 905.0 Modified Page 93 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Project: YANKO1204 Sample ID: 168404013 Client ID: YANKOOI Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 64 (15°/-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-/125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 96 (25%-0125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 72 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 73 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria* Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 94 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: 9106-0010-00IF 168404014 SE 04-MAY-06 17-MAY-06 Client 27.3%Project: YANKO 1204 Client ID: YANKOO Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00677 Curium-242 U 0.0854 Curium-243/244 U 0.0361 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.173 Plutonium-239/240 U -0.0342 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.0 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.0128 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.548 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0555 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -18.1 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.134+/-0.227+/-0.167+/-0.242 0.238 +/-0.227 0.00 +/-0.168 0.241 +/-0.242+/-0.181 0.143 +/-0.182+/-0.0865 0.0951 +/-0.0866+/-6.44 4.78 +/-6.54+/-0.0141 0.0125 +/-0.0141+/-7.50 6.25 +/-7.50+/-0.0809 0.0655 +/-0.0809+/-47.6 32.3 +/-47.6+/-0.205 0.167 +/-0.205 0.628 0.231 0.634 0.331 0.235 10.0 0.0262 13.5 0.137 66.6 0.347 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXL1 08/11/06 1434 555696 1 BXLI 08/11/06 2250 555697 2 BXL1 08/16/06 1553 555698 3 BXFI 08/14/06 0833 556350 4 DFAI 08/09/06 1454 554582 5 ATH2 08/09/06 2232 554583 6 MXPI 08/12/06 2005 555722 7 EGD1 08/11/06 2354 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 2 3 4 DOE EML HASL-300, Am-05-RC Modified DOE EML HASL-300, Pu-I I-RC Modified DOE EML HASL-300, Pu-11-RC Modified EPA 905.0 Modified Page 95 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-OOIF Project: YANK01204 Sample ID: 168404014 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALl 50 (15%-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 85 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu24 1, Solid-ALL FS 99 (25%-/125%)

Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 74 (25°%o- 125%)Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 70 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15/-,125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 96 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Report Date: August 21, 2006 Project: YANK01204 Client ID: YANK001 Vol. Recv.: Client Sample ID: Sample ID: Matrix: Collect Date: Receive Date: Collector:

Moisture: Parameter Qualifier Result Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.110 Curium-242 U -0.0547 Curium-243/244 U -0.126 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00157 Plutonium-239/240 U 0.0867 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U -0.00771 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.896 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0162 Liquid Scint Fe55, Solid ALL FSS Iron-55 U 23.3 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0577 The following Prep Methods were performed 9106-0010-012F 168404015 SE 04-MAY-06 17-MAY-06 Client 28.1%LC TPU Uncertainty

+/-0.184+/-0.141+/-0.184+/-0.126+/-0.0869+/-6.16 0.140 0.192 0.245 0.122 0.0406 4.77+/-0.184+/-0.141+/-0.185+/-0.126+/-0.0872+/-6.21 MDA 0.386 0.544 0.597 0.291 0.128 10.0 0.0263 11.0 0.132 67.0 0.354 Units DF Analyst Date Time Batch Mtd+/-0.0144 0.0124 +/-0.0144 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g BXLI 08/11/06 1434 555696 1 BXLI 08/11/06 2250 555697 2 BXLI 08/16/06 1609 555698 3 BXF1 08/14/06 0833 556350 4+/-6.17+/-0.0763+/-49.3+/-0.206 5.11 0.0633 32.5 0.171+/-6.17+/-0.0763+/-49.3+/-0.206 DFA1 ATH2 MXP1 EGD1 08/09/06 1510 554582 08/09/06 2334 554583 08/12/06 2021 555722 08/12/06 0010 554580 5 6 7 8 Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified LXM2 08/03/06 1534 554649 Page 97 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006 Contact: Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-012F Proiect: YANK01204 Sample ID: 168404015 Client ID: YANK001 Vol. Recv.: Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALl 81 (15°/-125%)

Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 99 (25%-125%)

Carrier/Tracer Recovery GFPC, SrO0, solid-ALL FSS 68 (250/6-125%)

Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 74 (15/-,125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-0125%)

Notes: The Qualifiers in this report are defined as follows:* A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.Page 98 of 105 QUALITY CONTROL DATA Page 99 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Client: Connecticut Yankee Atomic Power 362 Injun Hollow Rd Revort Date: August 21, 2006 Page 1 of 6 East Hampton, Connecticut Contact: Mr. Jack McCarthy Workorder:

168404 Parmna.mn NAMVI A')C RPrbO/,.RF- C 0/6 Ran e Anist Date Time Parmname NOM Sam le tlual nc Units RPD%Rad Alpha Spec Batch 555696 QC1201153130 168340011 DUP Americium-241 Curium-242 Curiumn-243/244 QC1201153132 LCS Americium-241 Curium-242 Curium-243/244 QC1201153129 MB Americium-241 Curium-242 Curium-243/244 QC1201153131 168340011 MS Americium-241 Curium-242 Curium-243/244 U -0.000522 Uncert: +/-0.0385 TPU: +/-0.0385 U 0.00 Uncert: +/-0.0756 TPU: +/-0.0756 U -0.0177 Uncert: +/-0.0764 TPU: +/-0.0765 12.8 Uncert: TPU: Uncert: TPU: 15.5 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU: 13.3 U -0.000522 Uncert: +/-0.0385 TPU: +/-0.0385 U 0.00 Uncert: +/-0.0756 TPU: +/-0.0756 16.1 U -0.0177 Uncert: +/-0.0764 TPU: +/-0.0765 U 0.0578+/-0.278+/-0.279 U -0.0405+/-0.0562+/-0.0565 U -0.0517+/-0.257+/-0.257 12.8+/-1.84+/-2.70 U -0.0328+/-0.0454+/-0.0457 14.3+/-1.94+/-2.92 U 0.0471+/-0.157+/-0.157 U -0.0469+/-0.0459+/-0.0464 U -0.00385+/-0.210+/-0.210 pCi/g 204 pCi/g 200 pCi/g 98 pCi/g (0%- 100%) BXLI 08/11/06 14:34 (0%- 100%)(0%- 100%)100 (75%-125%)

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 92 (75%-125%)

U 12.0+/-1.38+/-2.08 0.0427+/-0.0837+/-0.0839 15.9+1-1.58+/-2.61 91 (75%-125%)

99 (75%-125%)

Batch 555697 QC1201153134 168340011 DUP Plutonium-238 U -0.0155 U 0.0237 pCi/g 956 (0% -100%) BXLI 08/11/06 22:51 Page 100 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 2 of 6 Parmname NOM Samole Oual OC Units RPD%REC% Range Anist Date Time Rad Alpha Spec Batch 555697 Plutonium-239/240 QC1201153136 LCS Plutonium-238 Plutonium-239/240 QCI201153133 MB Plutonium-238 Plutonium-239/240 Uncert: +/-0.0215 TPU: +/-0.0216 U 0.0414 Uncert: +/-0.0934 TPU: +/-0.0935 Uncert: TPU: 11.8 Uncert: TPU: Uncert: TPU: Uncert: TPU: U -0.0155 Unceri: +/-0.0215 TPU: +/-0.0216 12.3 U 0.0414 Uncert: +/-0.0934 TPU: +/-0.0935 U 7.28 Unceri: +/-6.30 TPU: +/-6.35+/-0.0465+/-0.0466 U -0.0489+/-0.124+/-0.124 U 0.155+/-0.141+/-0.142 11.5+/-0.856+/-1.32 U 0.0552+/-0.186+/-0.186 U -0.0978+/-0.0892+/-0.0899 pCi/g 2410 (0%- 100%)(75%-1 25%)pCi/g pCi/g pCi/g pCi/g pCi/g pci/g 98 (75%-125%)

08/11/06 22:50 QC1201153135 168340011 MS Plutonium-238 U 0.0539+/-0.112+/-0.112 10.3+/-0.796+/-1.19 (75%-125%)

08/11/06 22:51 Plutonium-239/240 84 (75%-125%)

Batch 555698 QC1201153138 168340011 DUP Plutonium-241 QC1201153140 LCS Plutonium-241 QC1201153137 MB Plutonium-241 QC1201153139 168340011 MS Plutonium-241 U 10.1+/-6.39+/-6.46 pCi/g 0 (0% -100%) BXL I 137 Uncert: TPU: Uncert: TPU: 145+/-12.5+/-19.9 U 8.57+/-6.93+/-6.98 pCi/g pCi/g pCi/g 106 (75%-125%)

08/16/06 16:41 08/16/06 17:14 08/16/06 16:25 08/16/06 16:58 138 U Uncert: TPU: 7.28+/-6.30+/-6.35 Batch 557837 QC1201158317 168404009 DUP Americium-241 Curium-242 142+/-12.4+/-19.7 0.167+/-0.220+/-0.221 0.241 103 (75%-125%)

U -0.0851 Uncert: +/-0.136 TPU: +/-0.136 U -0.0253 U U pCi/g 616 pCi/g 247 (0%- 100%) BXLI 08/16/06 09:49 (0%- 100%)Page 101 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 3 of 6 Parmname Rad Alpha Spec Batch NOM Sam pLe _Qual QC Units RPD%REC% Range Anlst Date Time 557837 Curium-243/244 QC1201158319 Americium-241 Curium-242 Curium-243/244 QCI2O1158316 Americium-241 Uncert: +/-0.0495 TPU: +/-0.0496 U -0.0479 Unceri: +/-0.0542 TPU: +/-0.0545 LCS MB 24.5 Uncert: TPU: Uncert: TPU: 29.7 Uncert: TPU: Uncert: TPU: Uncert: TPU: Uncert: TPU:+/-0.334+/-0.335 U 0.0761+/-0.149+/-0.149 25.4+/-2.47+/-4.16 U 0.0477+/-0.127+/-0.127 27.0+/-2.54+/-4.38 U 0.234+/-0.275+/-0.277 U 0.00+/-0.152+/-0.152 U -0.0551+/-0.0624+/-0.0628 pCi/g 879 Curium-242 Curium-243/244 QC1201158318

.168404009 MS Americium-241 Curium-242 Curium-243/244 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 91 (75%-125%)

(0% -100%)104 (75%-125%)

26.4 U -0.0851 Uncert: +/-0.136 TPU: +/-0.136 U -0.0253 Uncert: +/-0.0495 TPU: +/-0.0496 32.4 U -0.0479 Uncert: +/-0.0542 TPU: +/-0.0545 U 29.1+/-2.97+/-5.01 0.126+/-0.247+/-0.248 31.7+/-3.12+/-5.39 110 (75%-125%)

98 (75%-125%)

Rad Gas Flow Batch 556350 QC1201154645 168404003 DUP Strontium-90 QC1201154647 LCS Strontium-90 QCI201154644 MB Strontium-90 U -0.00343 Uncert: +/-0.0203 TPU: +/-0.0203 1.56 Uncert: TPU: Uncert: TPU: U -0.00637+/-0.0152+/-0.0152 1.30+/-0.0563+/-0.0881 U 0.0176+/-0.018+/-0.018 pCi/g 0 (0% -100%) BXFI 08/14/06 08:33 pCi/g pCi/g 83 (75%-125%)

Page 102 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 4 of 6 REC% Range Anist Date Time Parmname NOM Samole Oual QC Units RPD%Rad Gas Flow Batch 556350 QC1201154646 168404003 MS Strontium-90 Rad Liquid Scintillation Batch 554580 QC1201150562 168340012 DUP Technetium-99 QC1201150564 LCS Technetium-99 QC1201150561 MB Technetium-99 QC1201150563 168340012 MS Technetium-99 1.58 U Uncert: TPU:-0.00343+/-0.0203+/-0.0203 1.29+/-0.0535+/-0.0813 pCi/g 82 (75%-125%)

U 0.0338 Uncert: +/-0.192 TPU: +/-0.192 U 0.266+/-0.226+/-0.226 13.6+/-0.496+/-0.599 pCi/g 0 (0%- 100%) EGDI 08/12/06 00:42 13.1 Uncert: TPU: Uncert: TPU: 13.0 U Uncert: TPU: U 0.0311+/-0.177+/-0.177 pCi/g pCi/g pCi/g 103 (75%-125%)

08/12/06 01:14 08/12/06 00:26 08/12/06 00:58 0.0338+/-0.192+/-0.192 12.0+/-0.523+/-0.602 92 (75%-125%)

Batch 554582 QC1201150570 168340011 DUP Tritium QC1201150572 LCS Tritium QC0201150569 MB Tritium QC1201150571 168340011 MS Tritium U 1.77 Uncert: +/-8.20 TPU: +/-8.20 U 1.62+/-7.47+/-7.47 pCi/g 0 (0% -100%) DFA1 68.3 Uncert: TPU: 76.2+/-14.0+/-14.1 Uncert: TPU: U 0.586+/-8.01+/-8.01 pCi/g pCi/g pCi/g 111 (75%-125%)

08/09/06 15:42 08/09/06 16:14 08/09/06 15:26 08/09/06 15:58 61.3 U Uncert: TPU: 1.77+/-8.20+/-8.20 Batch 554583 QC1201150574 168404003 DUP Carbon-14 QC1201150576 LCS Carbon- 14 QC1201150573 MB U 0.0937 Uncert: +/-0.0813 TPU: +/-0.0813 I1 61.8+/-12.2+/-12.3 0.0422+/-0.075+/-0.0751 7.14+/-0.508+/-0.520 101 (75%-125%)

pCi/g pCi/g 0 (0% -100%) ATH2 08/10/06 01:39 7.27 Uncert: TPU: 98 (75%-125%)

08/10/06 03:00 Page 103 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com Workorder:

168404 Parmname Rad Liquid Scintillation Batch 554583 Carbon- 14 QC1201150575 168404003 MS Carbon-14 Batch 555722 QC1201153223 168340012 DUP Iron-55 QC1201153225 LCS Iron-55 QC1201153222 MB Iron-55 QC1201153224 168340012 MS Iron-55 Batch 555723 QC1201153227 168340012 DUP Nickel-63 NOM Uncert: TPU 15.1 Uncert: TPU Uncert: TPU 641 Uncert: TPU Uncert: TPU 717 Uncert: TPU: QC Summary Sample Qual QC U -0.0315+/-0.0776+/-0.0776 U 0.0937 13.8+/-0.0813

+/-1.00+/-0.0813

+/-1.03 U -26.5 U 5.83+/-65.1 +/-36.9+/-65.1 +/-36.9 660+/-56.2+/-67.2 U 18.2+/-39.6+/-39.6 U -26.5 688+/-65.1 +/-60.2+/-65.1 +/-71.6 U 3.79 U 6.68 Page 5 of 6 Units RPD% REC% Range Anist Date Time pCi/g pCi/g 92 (75%-125%)

08/10/06 02:43 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 0 (0% -100%) viXP1 103 (75%-125%)

96 (75%-125%)

08/12/06 20:54 08/12/06 21:27 08/12/06 20:38 08/12/06 21:11 08/11/06 11:55 08/11/06 12:27 08/11/06 11:38 08/11/06 12:11 0 Uncert: +/-5.39 +/TPU: +/-5.40 +/QCI201153229 LCS Nickel-63 512 Uncert: +/TPU: +/QC1201153226 MB Nickel-63 U Uncert: +/TPU: +/QC1201153228 168340012 MS Nickel-63 530 U 3.79 Uncert: +/-5.39 +/TPU: +/-5.40 +/Notes: The Qualifiers in this report are defined as follows: A quality control analyte recovery is outside of specified acceptance criteria< Result is less than value reported Result is greater than value reported'-7.43/-7.43 479'-22.4'-27.1 15.7-9.92-9.93 511-23.5-28.7 (0% -100%) vAXPI 94 (75%-125%)

96 (75%-125%)

Page 104 of 105 GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -(843) 556-8171 -www.gel.com QC Summary Workorder:

168404 Page 6 of 6 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.** Indicates analyte is a surrogate compound.A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.Page 105 of 105 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD Attachment 2b Split Sample Assessment Forms (2 Pages)

Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey Area 9106 Survey 0003 Survey Discharge Canal#: Unit #: Unit Name: Sample Plan or WPIR#: 2006-021 SML #: 9106-0003-004 Sample

Description:

Comparison of split samples collected from sample measurement location #04 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0003-004F the comparison sample was 9106-0003-004FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)Value Error Range Value Error Ratio Cs-137 2.92E-01 2.50E-02 12 0.6- 1.66 3.14E-01 2.30E-02 1.08 Y Co-60 7.43E-01 3.61E-02 21 0.75- 1.33 9.84E-01 5.15E-02 1.32 Y Comments/Corrective Actions: N/A Table is provided to show acceptance criteria used to assess split samples.Resolution I Agreement Range 4 8 16 51 7 15 50 200> 200 0.50 0.60 0.75 0.80 0.85 2.00 1.66 1.33 1.25 1.18 Performed By: WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation Page I of I Connecticut Yankee Decommissioning Project Health Physics Procedure 24265-000-GPR-GGGR-R5124-000 Attachment A Split Sample Assessment Form Survey 9106 Survey 0003 Survey Unit Discharge Canal Area#: I Unit #: Name: Sample Plan or WPIR#: 2006-0021 SML #: 9106-0003-010 Sample

Description:

Comparison of split samples collected from sample measurement location #10 and analyzed using gamma spectroscopy by an off-site vendor laboratory.

The standard sample was 9106-0003-OIOF.

the comparison sample was 9106-0003-010FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)Value Error Range Value Error Ratio Cs-137 2.04E-01 2.08E-02 10 0.6- 1.66 1.69E-01 1.79E-02 0.83 Y Co-60 2.28E-01 2.54E-02 9 0.6- 1.66 0.OOE+00 2.02E-01 0.00 N K-40 1.24E+01 5.05E-01 25 0.75- 1.33 1.13E+01 4.91E-01 0.91 Y Comments/Corrective Actions: Since Co-60 has a likelyhood to Table is provided to show acceptance criteria used be present in the sample matrix in particulate form, one would to assess split samples.not neccassarily expect it to be homogenuously mixed from processing of the sample-split aliqot. Since both Cs-137 and K- Resolution Agreement Range 40 were also found to be present at an acceptable level of 4 7 0.50 2.00 agreement, no further action is warranted.

8 15 0.60 1.66 16 50 0.75 1.33 51 200 0.80 1.25> 200 0.85 1.18 Performed By: Date: Reviewed By: Date: 7-/3-06 WPIR -Work Plan and Inspection Record SML -Sample Measurement Location designation Page I of I DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD Attachment 2c Preliminary Data Forms (1 Page)

Health Physics Procedure GPP-GGGR-R512 1 -001 Attachment B, Rev. CY-00 I MAJOR Health Physics Procedure GPP-GGGR-R5 121-001 Attachment B, Rev. CY-00 1 MAJOR Preliminary Data Review Form -Samples for the Sign Test Survey Unit: 9106- 0003 Survey Unit Name: Discharge Canal Classification:

Survey Media: Type of Survey: Type of Measurement:

Number of Measurements:

Operational DCGL: 2 Soil Final Status Survey Radionuclide Specific 15 1 BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Minimum Value: 3.52E-04 1.45E-02 Maximum Value: 3.18E-01 8.05E-01 Mean: 1.48E-01 2.1OE-01 Median: 1.28E-01 1.07E-01 Standard Deviation:

1.16E-0 1 2.70E-0 I RADIONUCLIDE CONCENTRATION (pCi/g)NUMBER 9106-0003-001F 9106-0003-002F 9106-0003-003F 9106-0003-004F 9106-0003-005F 9106-0003-006F 9106-0003-007F 9106-0003-008F 9106-0003-009F 9106-0003-OIOF 9106-0003-012F 9106-0003-013F 9106-0003-014F 9106-0003-015F 9106-0003-016F Cs-137 1.28E-01 4.37E-02 3.93E-02 2.92E-01 2.10E-01 1.05E-01 2.64E-02 2.46E-01 3.18E-01 2.04E-01 4.27E-02 1.96E-02 2.91 E-01 2.57E-01 3.52E-04 Co-60 1.07E-01 1.89E-02 2.45E-02 7.43E-01 1.36E-01 1.86E-02 2.90E-02 1.09E-01 4.45E-01 2.28E-01 1.45E-02 2.41 E-02 4.33E-01 8.05E-01 2.02E-02 Identified?

Y Y Y Y Y Y Y Y Y Y Y N Y Y N Identified?

Y N Y Y Y N N Y Y Y N N Y Y Y Performed By: Independent Review: i~A~~r Date: 7 Date:

DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD Attachment 2d Graphical Representation of Data (4 Pages)

..1 Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Cesium -137 Survey Unit: 9106-0003 Survey Unit Name: Discharge Canal Mean: 1.48E-01 pCi/g Cs-137 Rank 3.52E-04 1 1.96E-02 2 2.64E-02 3 3.93E-02 4 4.27E-02 5 4.37E-02 6 1.05E-01 7 1.28E-01 8 1.90E-01 9 2.04E-01 10 2.10E-01 11 2.46E-01 12 2.57E-01 13 2.91 E-01 14 2.92E-01 15 3.18E-01 16 Percentage 3%9%16%22 %28 %34 %41%47 %53 %59 %66 %72 %78 %84 %91 %97 %Prepared By: Reviewed By: Date:>ý 13 -Oz Date: 7/3/4-jj Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Cobalt -60 Survey Unit: Survey Unit Name: Mean: 9106-0002 Discharge Canal 2.07E-01 pCi/g 7OOE-01 6.OOE-01 O5.OOE-01 0 4.00E-01 " 3.00E-01 o 2.00E-01-:


0.OOE+00 -. -0 20 40 60 80 100 Percentage Co-60 Rank Percentage 1.46E-03 1 3 %2.13E-02 2 10 %5.07E-02 3 17 %8.07E-02 4 23 %1.18E-01 5 30 %1.19E-01 6 37 %1.21E-01 7 43%1.45E-01 8 50 %1.51E-01 9 57 %2.31 E-01 10 63 %2.38E-01 11 70 %2.88E-01 12 77 %3.70E-01 13 83 %5.26E-01 14 90 %6.39E-01 15 97 %5 6,Z Prepared By: Reviewed By: Date: 7- Z Date: 12* 6 Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cesium -137 Survey Unit: Survey Unit Name: Mean: 9106-0003 Discharge Canal 0.148 pCi/g 7-6 5-a4-0 0.05 0.1 0.15 0.2 0.25 0.3 Upper End Value (pCi/g)Upper End Observation Observation Value Frequency Frequency 0.05 6 38%0.1 2 13%0.15 1 6%0.2 3 19%0.25 3 19%0.3 1 6%Total 16 100%/Aý) tý7AK V /Prepared By: Date:-//-

7-04 Date: //3/e6 Reviewed By:

Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Co -60 Survey Unit: 9106-0003 Survey Unit Name: Discharge Canal Mean: 0.210 pCi/g C)LL.8 7 6 5 4 3 2 1 Ii , .0-IK 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 Upper End Value (pCi/g)Upper End Observation Observation Value Frequency Frequency 0.10 7 44%0.20 4 25%0.30 1 6%0.40 0 0%0.50 2 13%0.60 0 0%0.70 1 6%0.80 1 6%Total 16 100%Prepared By: Reviewed By: Date: -Date: 2;'/5' -2 DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD Attachment 2e Sign Test Calculation (1 Page)

Health Physics Procedure GPP-GGGR-R5]2 1 -000 Attachment A, Rev. CY-00 I MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes SU Number: 9106-0003 Survey Unit Name: Discharge Canal WP&IR#: 2006-021 ITYPE I (a error):0.05 1 TYPE I (3 error):0.05 i Classification

2 Radionuclides:

Survey Design DCGL (pCi/g): Cs-137 Co-60 3.16 1.52 Results Cs-137 1.28E-01 4.37E-02 3.93E-02 2.92E-01 2.1OE-01 1.05E-01 2.64E-02 2.46E-0 I 3.18E-01 2.04E-01 4.27E-02 1.96E-02 2.91E-01 2.57E-01 3.52E-04 1.90E-01 Results Co-60 1.07E-01 1.89E-02 2.45E-02 7.43E-01 1.36E-01 1.86E-02 2.90E-02 1.09E-01 4.45E-01 2.28E-01 1.45E-02 2.41 E-02 4.33E-01 8.05E-01 2.02E-02 1.85E-01 Results Pu-241 2.20E+01 2.20E+01 2.20E+01 8.3 1E+00 2.20E+01 2.20E+01 2.20E+01 5.42E+01 2.20E+01 2.20E+0 1 2.20E+0 I 2.20E+0 1 1.90E+01 6.63E+00 2.20E+0 I 2.20E+01 Weighted Sum (Ws)(includes Pu-241 component) 1.48E-01 6.35E-02 6.58E-02 5.95E-01 1.93E-01 8.27E-02 6.47E-02 2.41E-01 4.3 1E-01 2.52E-01 6.03E-02 5.93E-02 4.09E-01 6.22E-0 I 5.06E-02 2.19E-01 DCGL-Result 8.52E-01 9.36E-01 9.34E-01 4.05E-01 8.07E-01 9.17E-01 9.35E-01 7.59E-01 5.69E-0 I 7.48E-01 9.40E-0 1 9.41E-01 5.91E-01 3.78E-01 9.49E-0 1 7.8 1E-01 Sign Number of Positive Differences (S+): 16 Critical Value: II Performed By: -/,?_Survey Unit: Meets Acceptance Criterion&48::,ýý2 Date: /- -0 Z Date: 1/i /3/oc Independent Review: Page 1 of I DISCHARGE CANAL SURVEY UNIT 9106-0003 RELEASE RECORD Attachment 2f COMPASS DQA Surface Soil Report with Retrospective Power Curve (4 Pages)

DQA Surface Soil Report Assessment Summary Site: Planner(s):

Survey Unit Name: Report Number: Survey Unit Samples: Reference Area Samples: Test Performed:

Judgmental Samples: Assessment

==

Conclusion:==

9106-0003 Dale Randall Discharge Canal 9106-0003 1 16 0 Sign Test Result: Not Performed 0 EMC Result: Not Performed Reject Null Hypothesis (Survey Unit PASSES)Retrospective Power Curve 4-U I a-Id 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0__Jil- -vi " -a 0.0 0.2 0.4 0.6 0.8 1.0 Unity Rule Sum-ef-Rails, includiug background

--Prospective Power 1 1-beta ....Actual Power ,- LBGR --Estimated Power DCGL ---- Retrospective Power 1.2 COMPASS v11.0.0 1012412006 Page I DQA Surface Soil Report Survey Unit Data NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9106-0003-001 F 9106-0003-002F 9106-0003-003F 9106-0003-004F 9106-0003-005F 9106-0003-006F 9106-0003-007F 9106-0003-008F 9106-0003-009F 9106-0003-01 OF 9106-0003-012F 9106-0003-013F 9106-0003-0115F 9106-0003-016F 9106-0003-018F 9106-0003-014F Type S S S S S S S S S S S S S S S S Co-60 (pCi/g)0.11 0.02 0.02 0.74 0.14 0.02 0.03 0.11 0.44 0.23 0.01 0.02 0.8 0.02 0.18 0.43 Cs-I 37 (pC ig)0.13 0.04 0.04 0.29 0.21 0.1 0.03 0.25 0.32 0.2 0.04 0.02 0.26 0 0.19 0.29 Modified Data (Unity Rule SOR)NOTE: Type = "S" indicates survey unit sample.Type = "R" indicates reference area sample.Sample Number 9106-0003-001 F 9106-0003-002F 9106-0003-003F 9106-0003-004F 9106-0003-005F 9106-0003-006F 9106-0003-007F 9106-0003-008F 9106-0003-009F 9106-0003-01 OF 9106-0003-012F 9106-0003-013F 9106-0003-015F 9106-0003-016F 9106-0003-018F 9106-0003-014F Type S S S S S S S S S S S S S S S S Sum-of-Ratios (SOR)0.11 0.03 0.03 0.58 0.16 0.05 0.03 0.15 0.39 0.21 0.02 0.02 0.61 0.01 0.18 0.38 COMPASS vl.0.0 1012412006 Page 2 U4 DQA Surface Soil Report Basic Statistical Quantities Summary Statistic Survey Unit Background DQO Results Sample Number 16 N/A N=15 Mean (SOR) 0.19 N/A 0.13 Median (SOR) 0.13 N/A N/A Std Dev (SOR) 0.20 N/A 0.26 High Value (SOR) 0.61 N/A N/A Low Value (SOR) 0.01 N/A N/A COMPASS vl.0.0 1012412006 Page 3 COMPASS v1.0.0 1012412006 Page 3