{{#Wiki_filter:DOCUMENT CONTAINS | {{#Wiki_filter:DOCUMENT CONTAINS | ||
SAFEGUARDS INFORMATION | |||
DOCUMENT CONTAINS | |||
ENCLOSURE(S) CONTAIN(S) | |||
SAFEGUARDS INFORMATION | |||
SAFEGUARDS INFORMATION | |||
UPON SEPARATION THIS | |||
PAGE IS DECONTROLLED | |||
January 22, 2004 | |||
Jeffrey S. Forbes, Site Vice President | Jeffrey S. Forbes, Site Vice President | ||
Arkansas Nuclear One | Arkansas Nuclear One | ||
Entergy Operations, Inc. | Entergy Operations, Inc. | ||
1448 S.R. 333 | 1448 S.R. 333 | ||
Russellville, AR 72801-0967 | Russellville, AR 72801-0967 | ||
SUBJECT: ARKANSAS NUCLEAR ONE - NRC PHYSICAL SECURITY LIMITED BASELINE | SUBJECT: ARKANSAS NUCLEAR ONE - NRC PHYSICAL SECURITY LIMITED BASELINE | ||
INSPECTION REPORT 05000313/2003013 AND 05000368/2003013 | |||
Dear Mr. Anderson: | Dear Mr. Anderson: | ||
On August 28, 2003, the NRC completed the onsite portion of an inspection at your Arkansas | On August 28, 2003, the NRC completed the onsite portion of an inspection at your Arkansas | ||
Nuclear One facility. The enclosed report documents the inspection findings, which were | Nuclear One facility. The enclosed report documents the inspection findings, which were | ||
discussed on January 12, 2004, with Mr. Richard Scheide, Licensing Engineer, and other | discussed on January 12, 2004, with Mr. Richard Scheide, Licensing Engineer, and other | ||
members of your staff. | members of your staff. | ||
This inspection examined activities conducted under your licenses as they relate to safety and | This inspection examined activities conducted under your licenses as they relate to safety and | ||
compliance with the Commissions rules and regulations and with the conditions of your | compliance with the Commissions rules and regulations and with the conditions of your | ||
licenses. Within these areas, the inspection consisted of selected examination of procedures | licenses. Within these areas, the inspection consisted of selected examination of procedures | ||
and representative records, observations of activities, and interviews with personnel. | and representative records, observations of activities, and interviews with personnel. | ||
The material enclosed herewith contains Safeguards Information as defined by 10 CFR 73.21 | The material enclosed herewith contains Safeguards Information as defined by 10 CFR 73.21 | ||
and its disclosure to unauthorized individuals is prohibited by Section 147 of the Atomic Energy | and its disclosure to unauthorized individuals is prohibited by Section 147 of the Atomic Energy | ||
Act of 1954, as amended. Therefore, the material will not be placed in the Public Document | Act of 1954, as amended. Therefore, the material will not be placed in the Public Document | ||
Room. | Room. | ||
In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter, without | In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter, without | ||
enclosure, will be available electronically for public inspection in the NRC Public Document | enclosure, will be available electronically for public inspection in the NRC Public Document | ||
Room or from the Publicly Available Records (PARS) component of NRCs document system | Room or from the Publicly Available Records (PARS) component of NRCs document system | ||
(ADAMS). ADAMS is accessible from the NRC Web site at | (ADAMS). ADAMS is accessible from the NRC Web site at | ||
http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). | http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). | ||
Entergy Operations, Inc. | Entergy Operations, Inc. | ||
DOCUMENT CONTAINS | |||
SAFEGUARDS INFORMATION | |||
-2- | |||
DOCUMENT CONTAINS | |||
ENCLOSURE(S) CONTAIN(S) | |||
SAFEGUARDS INFORMATION | |||
SAFEGUARDS INFORMATION | |||
UPON SEPARATION THIS | |||
PAGE IS DECONTROLLED | |||
Should you have any questions concerning this inspection, we would be pleased to discuss | Should you have any questions concerning this inspection, we would be pleased to discuss | ||
them with you. | them with you. | ||
Sincerely, | |||
//RA// | |||
Troy W. Pruett | |||
Plant Support Branch | |||
Division of Reactor Safety | |||
Dockets: 50-313 | Dockets: 50-313 | ||
50-368 | |||
Licenses: DPR-51 | Licenses: DPR-51 | ||
NPF-6 | |||
Enclosure: | Enclosure: | ||
NRC Inspection Report | NRC Inspection Report | ||
05000313; 05000368/2003-013 w/Attachment: | 05000313; 05000368/2003-013 w/Attachment: | ||
Supplemental Information | |||
cc without safeguards enclosure: | cc without safeguards enclosure: | ||
Senior Vice President | Senior Vice President | ||
& Chief Operating Officer | & Chief Operating Officer | ||
Entergy Operations, Inc. | Entergy Operations, Inc. | ||
P.O. Box 31995 | P.O. Box 31995 | ||
Jackson, MS 39286-1995 | Jackson, MS 39286-1995 | ||
Vice President | Vice President | ||
Operations Support | Operations Support | ||
Entergy Operations, Inc. | Entergy Operations, Inc. | ||
P.O. Box 31995 | P.O. Box 31995 | ||
Jackson, MS 39286-1995 | Jackson, MS 39286-1995 | ||
Manager, Washington Nuclear Operations | Manager, Washington Nuclear Operations | ||
ABB Combustion Engineering Nuclear | ABB Combustion Engineering Nuclear | ||
Power | Power | ||
12300 Twinbrook Parkway, Suite 330 | 12300 Twinbrook Parkway, Suite 330 | ||
Rockville, MD 20852 | Rockville, MD 20852 | ||
Entergy Operations, Inc. | Entergy Operations, Inc. | ||
DOCUMENT CONTAINS | |||
SAFEGUARDS INFORMATION | |||
-3- | |||
DOCUMENT CONTAINS | |||
ENCLOSURE(S) CONTAIN(S) | |||
SAFEGUARDS INFORMATION | |||
SAFEGUARDS INFORMATION | |||
UPON SEPARATION THIS | |||
PAGE IS DECONTROLLED | |||
County Judge of Pope County | County Judge of Pope County | ||
Pope County Courthouse | Pope County Courthouse | ||
100 West Main Street | 100 West Main Street | ||
Russellville, AR 72801 | Russellville, AR 72801 | ||
Winston & Strawn | Winston & Strawn | ||
1400 L Street, N.W. | 1400 L Street, N.W. | ||
Washington, DC 20005-3502 | Washington, DC 20005-3502 | ||
Bernard Bevill | Bernard Bevill | ||
Radiation Control Team Leader | Radiation Control Team Leader | ||
Division of Radiation Control and | Division of Radiation Control and | ||
Emergency Management | |||
Arkansas Department of Health | Arkansas Department of Health | ||
4815 West Markham Street, Mail Slot 30 | 4815 West Markham Street, Mail Slot 30 | ||
Little Rock, AR 72205-3867 | Little Rock, AR 72205-3867 | ||
Mike Schoppman | Mike Schoppman | ||
Framatome ANP, Inc. | Framatome ANP, Inc. | ||
Suite 705 | Suite 705 | ||
1911 North Fort Myer Drive | 1911 North Fort Myer Drive | ||
Rosslyn, VA 22209 | Rosslyn, VA 22209 | ||
SAFEGUARDS INFORMATION | |||
-4- | |||
DOCUMENT CONTAINS | |||
ENCLOSURE(S) CONTAIN(S) | |||
SAFEGUARDS INFORMATION | |||
SAFEGUARDS INFORMATION | |||
UPON SEPARATION THIS | |||
PAGE IS DECONTROLLED | |||
cc w/encl (SAFEGUARDS INFORMATION) | cc w/encl (SAFEGUARDS INFORMATION) | ||
E. McNeil (NSIR/DNS/RSS) | E. McNeil (NSIR/DNS/RSS) | ||
B. Westreich (NSIR/DNS) | B. Westreich (NSIR/DNS) | ||
RIV Docket File - File Room Custodian | RIV Docket File - File Room Custodian | ||
| Line 132: | Line 150: | ||
Anne Boland, OEDO RIV Coordinator (ATB) | Anne Boland, OEDO RIV Coordinator (ATB) | ||
ANO Site Secretary (VLH) | ANO Site Secretary (VLH) | ||
ADAMS: Yes | ADAMS: Yes | ||
Publicly Available | No Initials: _TWP_____ | ||
Publicly Available | |||
Non-Publicly Available | |||
Sensitive | |||
Non-Sensitive | |||
DOCUMENT: ML040220834.wpd | DOCUMENT: ML040220834.wpd | ||
RIV: PSB/PSI | |||
PSB/SPSI | |||
DRP/D | |||
C:PSB | |||
OFFICIAL RECORD COPY | JLBuchanan:jlh | ||
GAPick | |||
JAClark | |||
TWPruett | |||
/RA/ | |||
/RA/ | |||
/RA/ | |||
1/15 /04 | |||
1/ /04 | |||
1/16 /04 | |||
1/15 /04 | |||
OFFICIAL RECORD COPY | |||
T=Telephone E=E-mail F=Fax | |||
}} | }} | ||
Latest revision as of 05:26, 16 January 2025
| ML040220834 | |
| Person / Time | |
|---|---|
| Site: | Arkansas Nuclear |
| Issue date: | 01/22/2004 |
| From: | Troy Pruett Plant Support Branch Region IV |
| To: | Forbes J Entergy Operations |
| References | |
| IR-03-013 | |
| Download: ML040220834 (5) | |
See also: IR 05000313/2003013
Text
DOCUMENT CONTAINS
SAFEGUARDS INFORMATION
DOCUMENT CONTAINS
ENCLOSURE(S) CONTAIN(S)
SAFEGUARDS INFORMATION
SAFEGUARDS INFORMATION
UPON SEPARATION THIS
PAGE IS DECONTROLLED
January 22, 2004
Jeffrey S. Forbes, Site Vice President
Arkansas Nuclear One
Entergy Operations, Inc.
1448 S.R. 333
Russellville, AR 72801-0967
SUBJECT: ARKANSAS NUCLEAR ONE - NRC PHYSICAL SECURITY LIMITED BASELINE
INSPECTION REPORT 05000313/2003013 AND 05000368/2003013
Dear Mr. Anderson:
On August 28, 2003, the NRC completed the onsite portion of an inspection at your Arkansas
Nuclear One facility. The enclosed report documents the inspection findings, which were
discussed on January 12, 2004, with Mr. Richard Scheide, Licensing Engineer, and other
members of your staff.
This inspection examined activities conducted under your licenses as they relate to safety and
compliance with the Commissions rules and regulations and with the conditions of your
licenses. Within these areas, the inspection consisted of selected examination of procedures
and representative records, observations of activities, and interviews with personnel.
The material enclosed herewith contains Safeguards Information as defined by 10 CFR 73.21
and its disclosure to unauthorized individuals is prohibited by Section 147 of the Atomic Energy
Act of 1954, as amended. Therefore, the material will not be placed in the Public Document
Room.
In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter, without
enclosure, will be available electronically for public inspection in the NRC Public Document
Room or from the Publicly Available Records (PARS) component of NRCs document system
(ADAMS). ADAMS is accessible from the NRC Web site at
http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Entergy Operations, Inc.
DOCUMENT CONTAINS
SAFEGUARDS INFORMATION
-2-
DOCUMENT CONTAINS
ENCLOSURE(S) CONTAIN(S)
SAFEGUARDS INFORMATION
SAFEGUARDS INFORMATION
UPON SEPARATION THIS
PAGE IS DECONTROLLED
Should you have any questions concerning this inspection, we would be pleased to discuss
them with you.
Sincerely,
//RA//
Troy W. Pruett
Plant Support Branch
Division of Reactor Safety
Dockets: 50-313
50-368
Licenses: DPR-51
Enclosure:
NRC Inspection Report
05000313; 05000368/2003-013 w/Attachment:
Supplemental Information
cc without safeguards enclosure:
Senior Vice President
& Chief Operating Officer
Entergy Operations, Inc.
P.O. Box 31995
Jackson, MS 39286-1995
Vice President
Operations Support
Entergy Operations, Inc.
P.O. Box 31995
Jackson, MS 39286-1995
Manager, Washington Nuclear Operations
ABB Combustion Engineering Nuclear
Power
12300 Twinbrook Parkway, Suite 330
Rockville, MD 20852
Entergy Operations, Inc.
DOCUMENT CONTAINS
SAFEGUARDS INFORMATION
-3-
DOCUMENT CONTAINS
ENCLOSURE(S) CONTAIN(S)
SAFEGUARDS INFORMATION
SAFEGUARDS INFORMATION
UPON SEPARATION THIS
PAGE IS DECONTROLLED
County Judge of Pope County
Pope County Courthouse
100 West Main Street
Russellville, AR 72801
Winston & Strawn
1400 L Street, N.W.
Washington, DC 20005-3502
Bernard Bevill
Radiation Control Team Leader
Division of Radiation Control and
Emergency Management
4815 West Markham Street, Mail Slot 30
Little Rock, AR 72205-3867
Mike Schoppman
Framatome ANP, Inc.
Suite 705
1911 North Fort Myer Drive
Rosslyn, VA 22209
SAFEGUARDS INFORMATION
-4-
DOCUMENT CONTAINS
ENCLOSURE(S) CONTAIN(S)
SAFEGUARDS INFORMATION
SAFEGUARDS INFORMATION
UPON SEPARATION THIS
PAGE IS DECONTROLLED
cc w/encl (SAFEGUARDS INFORMATION)
E. McNeil (NSIR/DNS/RSS)
B. Westreich (NSIR/DNS)
RIV Docket File - File Room Custodian
Security Inspector (Pick)
Electronic distribution by RIV:
Regional Administrator (BSM1)
DRP Director (ATH)
DRS Director (DDC)
Senior Resident Inspector (RWD)
Branch Chief, DRP/D (LJS)
Senior Project Engineer, DRP/D (JLT2)
Staff Chief, DRP/TSS (PHH)
RITS Coordinator (NBH)
Anne Boland, OEDO RIV Coordinator (ATB)
ANO Site Secretary (VLH)
ADAMS: Yes
No Initials: _TWP_____
Publicly Available
Non-Publicly Available
Sensitive
Non-Sensitive
DOCUMENT: ML040220834.wpd
RIV: PSB/PSI
PSB/SPSI
DRP/D
C:PSB
JLBuchanan:jlh
GAPick
JAClark
TWPruett
/RA/
/RA/
/RA/
1/15 /04
1/ /04
1/16 /04
1/15 /04
OFFICIAL RECORD COPY