ML062500239: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:From: Ed MillerTo:Thomas.loomis@exeloncorp.comDate: 09/07/2006 9:07:50 AM
{{#Wiki_filter:From:             Ed Miller To:               Thomas.loomis@exeloncorp.com Date:             09/07/2006 9:07:50 AM


==Subject:==
==Subject:==
Roll RepairTom, After talking with Simon, he communicated that for future inservice inspection for repaired
Roll Repair
: Tom, After talking with Simon, he communicated that for future inservice inspection for repaired CRD housing penetrations 42-43 and 46-39, your response dated June 23, 2006, to NRCs request for additional information needs clarification. Please confirm whether you agree with the following (underlined):
NDE During Roll Repair of Table 1:
Appendix I (of code case N-730) refers to procedure demonstration utilizing, in part, ASME Section XI, Appendix VIII, Supplement 2. Supplement 2 was not implemented at the time of the original repair. A plant specific mockup will be available for future inservice inspection of CRD housing penetrations 42-43 and 46-39 and in the event that additional roll repairs are necessary that will comply with the Appendix I requirements. As discussed in the proposed relief request, an ultrasonic exam of the inside diameter of CRD housing 46-39 was performed in the R20 outage (Fall 2004). No indications were identified....
Ed Miller 415-2481


CRD housing penetrations 42-43 and 46-39, your response dated June 23, 2006, to NRC'srequest for additional information needs clarification. Please confirm whether you agree with the following (underlined):
Mail Envelope Properties (450019A6.EDB : 9 : 35080)
 
"NDE During Roll Repair" of Table 1: 
 
Appendix I (of code case N-730) refers to procedure demonstration utilizing, in part, ASMESection XI, Appendix VIII, Supplement 2. Supplement 2 was not implemented at the time of theoriginal repair. A plant specific mockup will be available for future inservice inspection of CRDhousing penetrations 42-43 and 46-39 and in the event that additional roll repairs are necessarythat will comply with the Appendix I requirements. As discussed in the proposed relief request,an ultrasonic exam of the inside diameter of CRD housing 46-39 was performed in the R20outage (Fall 2004). No indications were identified....
 
Ed Miller 415-2481 Mail Envelope Properties(450019A6.EDB : 9 : 35080)


==Subject:==
==Subject:==
Roll RepairCreation Date 09/07/2006 9:07:50 AMFrom: Ed MillerCreated By:GXM@nrc.govRecipientsActionDate & Timeexeloncorp.comTransferred09/07/2006 9:08:03
Roll Repair Creation Date         09/07/2006 9:07:50 AM From:                 Ed Miller Created By:           GXM@nrc.gov Recipients                                      Action              Date & Time exeloncorp.com                                  Transferred          09/07/2006 9:08:03 AM thomas.loomis (Thomas.loomis@exeloncorp.com)
 
Post Office                                     Delivered            Route exeloncorp.com Files                          Size              Date & Time MESSAGE                        1529              09/07/2006 9:07:50 AM TEXT.htm                      1419 Options Auto Delete:                   No Expiration Date:               None Notify Recipients:             Yes Priority:                     Standard ReplyRequested:               No Return Notification:           None Concealed  
AM thomas.loomis (Thomas.loomis@exeloncorp.com)Post Office DeliveredRouteexeloncorp.comFilesSizeDate & Time MESSAGE152909/07/2006 9:07:50 AM TEXT.htm1419Options Auto Delete:
No Expiration Date:None Notify Recipients:Yes Priority:Standard ReplyRequested:
No Return Notification:None Concealed  


==Subject:==
==Subject:==
 
No Security:                     Standard To Be Delivered:               Immediate Status Tracking:               Delivered & Opened}}
No Security:Standard To Be Delivered:Immediate Status Tracking:Delivered & Opened}}

Revision as of 14:22, 23 November 2019

E-mail, Miller, NRR, to Loomis, Exelon, Oyster Creek Relief Request, Use of Code Case N-730
ML062500239
Person / Time
Site: Oyster Creek
Issue date: 09/07/2006
From: Geoffrey Miller
NRC/NRR/ADRO/DORL/LPLB
To: Tom Loomis
Exelon Corp
Miller, G. Edward, 415-2481
References
TAC MD1070
Download: ML062500239 (2)


Text

From: Ed Miller To: Thomas.loomis@exeloncorp.com Date: 09/07/2006 9:07:50 AM

Subject:

Roll Repair

Tom, After talking with Simon, he communicated that for future inservice inspection for repaired CRD housing penetrations 42-43 and 46-39, your response dated June 23, 2006, to NRCs request for additional information needs clarification. Please confirm whether you agree with the following (underlined):

NDE During Roll Repair of Table 1:

Appendix I (of code case N-730) refers to procedure demonstration utilizing, in part, ASME Section XI, Appendix VIII, Supplement 2. Supplement 2 was not implemented at the time of the original repair. A plant specific mockup will be available for future inservice inspection of CRD housing penetrations 42-43 and 46-39 and in the event that additional roll repairs are necessary that will comply with the Appendix I requirements. As discussed in the proposed relief request, an ultrasonic exam of the inside diameter of CRD housing 46-39 was performed in the R20 outage (Fall 2004). No indications were identified....

Ed Miller 415-2481

Mail Envelope Properties (450019A6.EDB : 9 : 35080)

Subject:

Roll Repair Creation Date 09/07/2006 9:07:50 AM From: Ed Miller Created By: GXM@nrc.gov Recipients Action Date & Time exeloncorp.com Transferred 09/07/2006 9:08:03 AM thomas.loomis (Thomas.loomis@exeloncorp.com)

Post Office Delivered Route exeloncorp.com Files Size Date & Time MESSAGE 1529 09/07/2006 9:07:50 AM TEXT.htm 1419 Options Auto Delete: No Expiration Date: None Notify Recipients: Yes Priority: Standard ReplyRequested: No Return Notification: None Concealed

Subject:

No Security: Standard To Be Delivered: Immediate Status Tracking: Delivered & Opened