ML062500239

From kanterella
Jump to navigation Jump to search

E-mail, Miller, NRR, to Loomis, Exelon, Oyster Creek Relief Request, Use of Code Case N-730
ML062500239
Person / Time
Site: Oyster Creek
Issue date: 09/07/2006
From: Geoffrey Miller
NRC/NRR/ADRO/DORL/LPLB
To: Tom Loomis
Exelon Corp
Miller, G. Edward, 415-2481
References
TAC MD1070
Download: ML062500239 (2)


Text

From:

Ed Miller To:

Thomas.loomis@exeloncorp.com Date:

09/07/2006 9:07:50 AM

Subject:

Roll Repair

Tom, After talking with Simon, he communicated that for future inservice inspection for repaired CRD housing penetrations 42-43 and 46-39, your response dated June 23, 2006, to NRCs request for additional information needs clarification. Please confirm whether you agree with the following (underlined):

NDE During Roll Repair of Table 1:

Appendix I (of code case N-730) refers to procedure demonstration utilizing, in part, ASME Section XI, Appendix VIII, Supplement 2. Supplement 2 was not implemented at the time of the original repair. A plant specific mockup will be available for future inservice inspection of CRD housing penetrations 42-43 and 46-39 and in the event that additional roll repairs are necessary that will comply with the Appendix I requirements. As discussed in the proposed relief request, an ultrasonic exam of the inside diameter of CRD housing 46-39 was performed in the R20 outage (Fall 2004). No indications were identified....

Ed Miller 415-2481

Mail Envelope Properties (450019A6.EDB : 9 : 35080)

Subject:

Roll Repair Creation Date 09/07/2006 9:07:50 AM From:

Ed Miller Created By:

GXM@nrc.gov Recipients Action Date & Time exeloncorp.com Transferred 09/07/2006 9:08:03 AM thomas.loomis (Thomas.loomis@exeloncorp.com)

Post Office Delivered Route exeloncorp.com Files Size Date & Time MESSAGE 1529 09/07/2006 9:07:50 AM TEXT.htm 1419 Options Auto Delete:

No Expiration Date:

None Notify Recipients:

Yes Priority:

Standard ReplyRequested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard To Be Delivered:

Immediate Status Tracking:

Delivered & Opened