| description = The inspectors identified a finding of very low safety significance (Green) with an associated Non-Cited Violation (NCV) of    Title 10 of the Code of Federal Regulations (CFR) Part 50, Appendix B Criterion V for the failure to accomplish activities affecting quality as prescribed by documented procedures.  Specifically, the licensee failed to follow procedure 4 AWI04.02.01, Housekeeping for storage of items or equipment near safety-related equipment.  On two separate occasions, the inspectors identified items being stored near safety-related equipment that did not comply with procedure requirements.
| description = The inspectors identified a finding of very low safety significance (Green) with an associated Non-Cited Violation (NCV) of    Title 10 of the Code of Federal Regulations (CFR) Part 50, Appendix B Criterion V for the failure to accomplish activities affecting quality as prescribed by documented procedures.  Specifically, the licensee failed to follow procedure 4 AWI04.02.01, Housekeeping for storage of items or equipment near safety-related equipment.  On two separate occasions, the inspectors identified items being stored near safety-related equipment that did not comply with procedure requirements.
}}
}}

Latest revision as of 17:34, 10 September 2018

01
Site: Monticello Xcel Energy icon.png
Report IR 05000263/2018001 Section 1R04
Date counted Mar 31, 2018 (2018Q1)
Type: NCV: Green
cornerstone Mitigating Systems
Identified by: NRC identified
Inspection Procedure: IP 71111.04
Inspectors (proximate) P Zurawski
D Krause
J Mancuso
T Go
K Riemer
Violation of: 10 CFR 50 Appendix B

10 CFR 50 Appendix B Criterion V
INPO aspect WP.1
'