{{#Wiki_filter:From: | {{#Wiki_filter:From: | ||
Ed Miller To: | |||
Thomas.loomis@exeloncorp.com Date: | |||
09/07/2006 9:07:50 AM | |||
==Subject:== | ==Subject:== | ||
| Line 30: | Line 33: | ||
==Subject:== | ==Subject:== | ||
Roll Repair Creation Date | Roll Repair Creation Date 09/07/2006 9:07:50 AM From: | ||
Post Office | Ed Miller Created By: | ||
GXM@nrc.gov Recipients Action Date & Time exeloncorp.com Transferred 09/07/2006 9:08:03 AM thomas.loomis (Thomas.loomis@exeloncorp.com) | |||
Post Office Delivered Route exeloncorp.com Files Size Date & Time MESSAGE 1529 09/07/2006 9:07:50 AM TEXT.htm 1419 Options Auto Delete: | |||
No Expiration Date: | |||
None Notify Recipients: | |||
Yes Priority: | |||
Standard ReplyRequested: | |||
No Return Notification: | |||
None Concealed | |||
==Subject:== | ==Subject:== | ||
No Security: | No Security: | ||
Standard To Be Delivered: | |||
Immediate Status Tracking: | |||
Delivered & Opened}} | |||
Latest revision as of 06:54, 15 January 2025
| ML062500239 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 09/07/2006 |
| From: | Geoffrey Miller NRC/NRR/ADRO/DORL/LPLB |
| To: | Tom Loomis Exelon Corp |
| Miller, G. Edward, 415-2481 | |
| References | |
| TAC MD1070 | |
| Download: ML062500239 (2) | |
Text
From:
Ed Miller To:
Thomas.loomis@exeloncorp.com Date:
09/07/2006 9:07:50 AM
Subject:
Roll Repair
- Tom, After talking with Simon, he communicated that for future inservice inspection for repaired CRD housing penetrations 42-43 and 46-39, your response dated June 23, 2006, to NRCs request for additional information needs clarification. Please confirm whether you agree with the following (underlined):
NDE During Roll Repair of Table 1:
Appendix I (of code case N-730) refers to procedure demonstration utilizing, in part, ASME Section XI, Appendix VIII, Supplement 2. Supplement 2 was not implemented at the time of the original repair. A plant specific mockup will be available for future inservice inspection of CRD housing penetrations 42-43 and 46-39 and in the event that additional roll repairs are necessary that will comply with the Appendix I requirements. As discussed in the proposed relief request, an ultrasonic exam of the inside diameter of CRD housing 46-39 was performed in the R20 outage (Fall 2004). No indications were identified....
Ed Miller 415-2481
Mail Envelope Properties (450019A6.EDB : 9 : 35080)
Subject:
Roll Repair Creation Date 09/07/2006 9:07:50 AM From:
Ed Miller Created By:
GXM@nrc.gov Recipients Action Date & Time exeloncorp.com Transferred 09/07/2006 9:08:03 AM thomas.loomis (Thomas.loomis@exeloncorp.com)