Line 3: Line 3:
| issue date = 08/06/2010
| issue date = 08/06/2010
| title = IR 05000369-10-201, 05000370-10-201, on 05/25/2009, William B. McGuire Nuclear Station Security Inspection
| title = IR 05000369-10-201, 05000370-10-201, on 05/25/2009, William B. McGuire Nuclear Station Security Inspection
| author name = Johnson R C
| author name = Johnson R
| author affiliation = NRC/NSIR
| author affiliation = NRC/NSIR
| addressee name = Repko R T
| addressee name = Repko R
| addressee affiliation = Duke Energy Corp
| addressee affiliation = Duke Energy Corp
| docket = 05000369, 05000370
| docket = 05000369, 05000370
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:
{{#Wiki_filter:August 6, 2010
[[Issue date::August 6, 2010]]


Mr. Regis Vice President McGuire Nuclear Station
==SUBJECT:==
MCGUIRE NUCLEAR STATION - U. S. NUCLEAR REGULATORY COMMISSION SECURITY BASELINE INSPECTION REPORT 05000369/2010201 AND 05000370/2010201


Duke Electric Corporation 12700 Hagers Ferry Road Huntersville, NC 28078-8985
==Dear Mr. Repko:==
On June 25, 2010, the U.S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at the McGuire Nuclear Station. The inspection covered one or more of the key attributes of the Security cornerstone of the NRCs Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on July 7, 2010, with members of the site staff.


SUBJECT: MCGUIRE NUCLEAR STATION - U. S. NUCLEAR REGULATORY COMMISSION SECURITY BASELINE INSPECTION REPORT 05000369/2010201 AND 05000370/2010201
The inspection examined activities conducted under your license as they relate to security and compliance with the Commissions rules and regulations and with the conditions of your license.
 
==Dear Mr. Repko:==
On June 25, 2010, the U.S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at the McGuire Nuclear Station. The inspection covered one or more of the key attributes of the Security cornerstone of the NRC's Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on July 7, 2010, with members of the site staff.


The inspection examined activities conducted under your license as they relate to security and compliance with the Commission's rules and regulations and with the conditions of your license. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.
The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.


No findings of significance were identified.
No findings of significance were identified.


In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agency-wide Documents Access and M anagement Systems (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (The Public Electronic Reading Room). However, because of the security-related concerns contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letter's enclosures will not be available for public inspection.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRCs Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs Agency-wide Documents Access and Management Systems (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (The Public Electronic Reading Room). However, because of the security-related concerns contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letters enclosures will not be available for public inspection.


In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRC's document system, ADAMS. If Safeguards Information is necessary to provide an acceptable . response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response "Security-Related Information-Withhold Under 10 CFR 2.390" and follow the instructions for withholding in 10 CFR 2.390(b)(1).
In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system, ADAMS. If Safeguards Information is necessary to provide an acceptable response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response Security-Related Information-Withhold Under 10 CFR 2.390 and follow the instructions for withholding in 10 CFR 2.390(b)(1).


Should you have any questions concerning this letter, please contact us. Your cooperation is appreciated.
Should you have any questions concerning this letter, please contact us. Your cooperation is appreciated.


Sincerely,/RA/ Robert C. Johnson, Chief Security Performance Evaluation Branch Division of Security Operations Office of Nuclear Security and Incident Response
Sincerely,
 
/RA/  
Docket Nos.: 50-369, 50-370
 
License Nos.: NPF-9, NPF-17
 
Nonpublic


===Enclosure:===
Robert C. Johnson, Chief
Inspection Report 05000369/2010201 and 05000370/2010201 w/


===Attachments:===
Security Performance Evaluation Branch
Supplemental Information, Table of Security Personnel, Exercise One, Exercise Two, Exercise Three (SAFEGUARDS)


cc w/encl: Mr. David Black, Site Security Manager William B. McGuire Nuclear Station Duke Energy Corporation 12700 Hagers Ferry Road
Division of Security Operations Office of Nuclear Security and Incident Response


Huntersville, NC 28078 Ellis S. Sellers
Docket Nos.: 50-369, 50-370 License Nos.: NPF-9, NPF-17


Security Safeguards Administrator Duke Energy Carolinas, LLC McGuire Nuclear Station 12700 Hagers Ferry Road, MG01SC
Nonpublic Enclosure: Inspection Report 05000369/2010201 and 05000370/2010201 w/ Attachments: Supplemental Information, Table of Security Personnel, Exercise One, Exercise Two, Exercise Three (SAFEGUARDS)


Huntersville, NC 28078-8985 Timothy J. Wadsworth Security Specialist
cc w/encl:
Mr. David Black, Site Security Manager William B. McGuire Nuclear Station Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, NC 28078  


Duke Energy Carolinas, LLC P. O. Box 1006
Ellis S. Sellers Security Safeguards Administrator Duke Energy Carolinas, LLC McGuire Nuclear Station 12700 Hagers Ferry Road, MG01SC Huntersville, NC 28078-8985


526 S. Church St., EC05P Charlotte, NC 28201-1006
Timothy J. Wadsworth Security Specialist Duke Energy Carolinas, LLC P. O. Box 1006 526 S. Church St., EC05P Charlotte, NC 28201-1006
}}
}}

Latest revision as of 03:58, 14 January 2025

IR 05000369-10-201, 05000370-10-201, on 05/25/2009, William B. McGuire Nuclear Station Security Inspection
ML102040802
Person / Time
Site: Mcguire, McGuire  Duke Energy icon.png
Issue date: 08/06/2010
From: Rachel Johnson
Office of Nuclear Security and Incident Response
To: Repko R
Duke Energy Corp
References
IR-10-201
Download: ML102040802 (4)


Text

August 6, 2010

SUBJECT:

MCGUIRE NUCLEAR STATION - U. S. NUCLEAR REGULATORY COMMISSION SECURITY BASELINE INSPECTION REPORT 05000369/2010201 AND 05000370/2010201

Dear Mr. Repko:

On June 25, 2010, the U.S. Nuclear Regulatory Commission (NRC) completed a security baseline inspection at the McGuire Nuclear Station. The inspection covered one or more of the key attributes of the Security cornerstone of the NRCs Reactor Oversight Process. The enclosed inspection report documents the inspection results, which were discussed on July 7, 2010, with members of the site staff.

The inspection examined activities conducted under your license as they relate to security and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.

No findings of significance were identified.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRCs Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs Agency-wide Documents Access and Management Systems (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (The Public Electronic Reading Room). However, because of the security-related concerns contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letters enclosures will not be available for public inspection.

In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system, ADAMS. If Safeguards Information is necessary to provide an acceptable response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response Security-Related Information-Withhold Under 10 CFR 2.390 and follow the instructions for withholding in 10 CFR 2.390(b)(1).

Should you have any questions concerning this letter, please contact us. Your cooperation is appreciated.

Sincerely,

/RA/

Robert C. Johnson, Chief

Security Performance Evaluation Branch

Division of Security Operations Office of Nuclear Security and Incident Response

Docket Nos.: 50-369, 50-370 License Nos.: NPF-9, NPF-17

Nonpublic Enclosure: Inspection Report 05000369/2010201 and 05000370/2010201 w/ Attachments: Supplemental Information, Table of Security Personnel, Exercise One, Exercise Two, Exercise Three (SAFEGUARDS)

cc w/encl:

Mr. David Black, Site Security Manager William B. McGuire Nuclear Station Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, NC 28078

Ellis S. Sellers Security Safeguards Administrator Duke Energy Carolinas, LLC McGuire Nuclear Station 12700 Hagers Ferry Road, MG01SC Huntersville, NC 28078-8985

Timothy J. Wadsworth Security Specialist Duke Energy Carolinas, LLC P. O. Box 1006 526 S. Church St., EC05P Charlotte, NC 28201-1006