ML11178A067: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 2: Line 2:
| number = ML11178A067
| number = ML11178A067
| issue date = 06/23/2011
| issue date = 06/23/2011
| title = 06/23/11-Outline, Turkey Point Nuclear Plant, Units 3 and 4, Outline Epitome/Containment Volume RAI Response
| title = Outline, Turkey Point Nuclear Plant, Units 3 and 4, Outline Epitome/Containment Volume RAI Response
| author name = Paige J
| author name = Paige J
| author affiliation = NRC/NRR/DORL/LPLII-2
| author affiliation = NRC/NRR/DORL/LPLII-2
Line 19: Line 19:


=Text=
=Text=
{{#Wiki_filter:OUTLINE EPITOME/CONTAINMENT VOLUME RAI RESPONSE
{{#Wiki_filter:OUTLINE EPITOME/CONTAINMENT VOLUME RAI RESPONSE Cover Letter Attachment
- Cover Letter
- Attachment
: 1. RAI Introduction
: 1. RAI Introduction
: 2. Summary of EPITOME Issue
: 2. Summary of EPITOME Issue
Line 43: Line 41:
: d. Environmental Qualification of Electrical Equipment (2.3.1)
: d. Environmental Qualification of Electrical Equipment (2.3.1)
: e. Pressure Analysis for Emergency Core Cooling System Performance Capability (2.6.6)
: e. Pressure Analysis for Emergency Core Cooling System Performance Capability (2.6.6)
: f. Containment Ventilation System (2.7.7)
: f.
Containment Ventilation System (2.7.7)
: g. Emergency Core Cooling System and Loss-of-Coolant Accidents (2.8.4.4)
: g. Emergency Core Cooling System and Loss-of-Coolant Accidents (2.8.4.4)
: h. Radiological Consequences Analyses Using Alternative Source Terms (2.9.2)
: h. Radiological Consequences Analyses Using Alternative Source Terms (2.9.2)

Latest revision as of 05:41, 13 January 2025

Outline, Turkey Point Nuclear Plant, Units 3 and 4, Outline Epitome/Containment Volume RAI Response
ML11178A067
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 06/23/2011
From: Jason Paige
Plant Licensing Branch II
To:
Shared Package
ML11195A170 List:
References
TAC ME4907, TAC ME4908
Download: ML11178A067 (2)


Text

OUTLINE EPITOME/CONTAINMENT VOLUME RAI RESPONSE Cover Letter Attachment

1. RAI Introduction
2. Summary of EPITOME Issue
3. Other Input Considerations (Containment Volume, other changes, etc.)
4. Analyses
5. Summary of LOCA Results
a. Containment Integrity
b. PressurelTemperature Curves
6. Summary of MSLB Results
a. Containment Integrity
b. PressurelTemperature Curves
7. Areas Requiring Revised Analyses (applicable LAR sections in parentheses)
a. Reactor Auxiliary Cooling Water Systems (Component Cooling Water System) (2.5.4.3)
b. Primary Containment Functional Design (2.6.1)
c. Mass and Energy Release (2.6.3)
d. Containment Heat Removal (2.6.5)
8. Other Areas Reviewed with no Impact (applicable LAR sections in parentheses)
a. Protective Coating Systems (Paints) - Organic Materials (2.1.7)
b. Balance of Plant Piping, Components and Supports (2.2.2.2)
c. Safety-Related Valves and Pumps (2.2.4)
d. Environmental Qualification of Electrical Equipment (2.3.1)
e. Pressure Analysis for Emergency Core Cooling System Performance Capability (2.6.6)
f.

Containment Ventilation System (2.7.7)

g. Emergency Core Cooling System and Loss-of-Coolant Accidents (2.8.4.4)
h. Radiological Consequences Analyses Using Alternative Source Terms (2.9.2)
9. Conclusions
10. Proposed Technical Specification Change
a. Description of Change and Justification
b. No Significant Hazards Determination Fig. 1 - Marked-up Technical Specification Pages Fig. 2 - Marked-up Technical Specification Bases Pages (for information only)