ML16231A028: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 17: Line 17:
=Text=
=Text=
{{#Wiki_filter:From: Silko, Thomas B. [mailto:tsilko@entergy.com]
{{#Wiki_filter:From: Silko, Thomas B. [mailto:tsilko@entergy.com]
Sent: Thursday, August 11, 2016 11:26 AM To: Parrott, Jack <Jack.Parrott@nrc.gov>
Sent: Thursday, August 11, 2016 11:26 AM To: Parrott, Jack <Jack.Parrott@nrc.gov>  


==Subject:==
==Subject:==
Line 23: Line 23:
: Jack, Based upon our conversation on Wednesday 8/3/16, VY agreed to provide a copy of the Part 61 analysis which was used to identify the radionuclide concentrations on the Torus water. Accordingly, please find attached a copy of the Part 61 report from GEL Laboratories, dated April 26, 2016.
: Jack, Based upon our conversation on Wednesday 8/3/16, VY agreed to provide a copy of the Part 61 analysis which was used to identify the radionuclide concentrations on the Torus water. Accordingly, please find attached a copy of the Part 61 report from GEL Laboratories, dated April 26, 2016.
In response to the Staffs second question, VY and the NRC discussed the process for sampling of material prior to making radioactive shipments. VY procedure V-EN-RW-102, Shipment of Radioactive Material, requires an isotopic be performed to ensure the material is appropriately classified per 10 CFR 61.55 requirements. The isotopic is performed on a sample of the material (in this case a water sample) prior to completing the shipment manifest. As such, VY is committed to sampling water prior to shipment to satisfy the requirements of 10CFR61.55.
In response to the Staffs second question, VY and the NRC discussed the process for sampling of material prior to making radioactive shipments. VY procedure V-EN-RW-102, Shipment of Radioactive Material, requires an isotopic be performed to ensure the material is appropriately classified per 10 CFR 61.55 requirements. The isotopic is performed on a sample of the material (in this case a water sample) prior to completing the shipment manifest. As such, VY is committed to sampling water prior to shipment to satisfy the requirements of 10CFR61.55.
In addition, Vermont Yankee commits to the following: Vermont Yankee will perform a representative sample prior to each shipment of water and will confirm that the radionuclide concentrations result in doses that are equal to or less than, the doses delineated within the Summary of Project Alternative Disposal Dose Results, in our June 28, 2016 letter (BVY 16-021; ADAMS Accession No. ML16182A035).
In addition, Vermont Yankee commits to the following: Vermont Yankee will perform a representative sample prior to each shipment of water and will confirm that the radionuclide concentrations result in doses that are equal to or less than, the doses delineated within the Summary of Project Alternative Disposal Dose Results, in our {{letter dated|date=June 28, 2016|text=June 28, 2016 letter}} (BVY 16-021; ADAMS Accession No. ML16182A035).
For example, the above could be satisfied in the following manner: A representative sample is taken prior to a shipment and the radionuclide concentrations are verified to be equal to or less than those concentrations shown on the Data Input Worksheet, of our June 28, 2016 letter. An alternative method to be used, such as when a radionuclide is identified as being slightly above the concentrations (while others may be lower), then sample radionuclide concentrations would be input into the Site Specific Dose Assessment Methodology (SSDA) used in our June 28, 2016 letter and the dose consequences verified to be equal to or less than that delineated within the Summary of Project Alternative Disposal Dose Results.
For example, the above could be satisfied in the following manner: A representative sample is taken prior to a shipment and the radionuclide concentrations are verified to be equal to or less than those concentrations shown on the Data Input Worksheet, of our {{letter dated|date=June 28, 2016|text=June 28, 2016 letter}}. An alternative method to be used, such as when a radionuclide is identified as being slightly above the concentrations (while others may be lower), then sample radionuclide concentrations would be input into the Site Specific Dose Assessment Methodology (SSDA) used in our {{letter dated|date=June 28, 2016|text=June 28, 2016 letter}} and the dose consequences verified to be equal to or less than that delineated within the Summary of Project Alternative Disposal Dose Results.
Please let me know if there are any further questions.
Please let me know if there are any further questions.
Thank You.
Thank You.
Tom Silko (802) 451-3166
Tom Silko (802) 451-3166  


April 26, 2016 Mr. Mark Vandale Entergy Nuclear Operations, Inc., VY 530 Governor Hunt Road PO Box 250 Vernon, Vermont 05354 Re: Vermont Yankee Part 61 Work Order: 395827
April 26, 2016 Mr. Mark Vandale Entergy Nuclear Operations, Inc., VY 530 Governor Hunt Road PO Box 250 Vernon, Vermont 05354 Re: Vermont Yankee Part 61 Work Order: 395827  


==Dear Mr. Vandale:==
==Dear Mr. Vandale:==
GEL Laboratories, LLC (GEL) appreciates the opportunity to provide the enclosed analytical results for the sample(s) we received on April 21, 2016. This original data report has been prepared and reviewed in accordance with GELs standard operating procedures.
GEL Laboratories, LLC (GEL) appreciates the opportunity to provide the enclosed analytical results for the sample(s) we received on April 21, 2016. This original data report has been prepared and reviewed in accordance with GELs standard operating procedures.
Our policy is to provide high quality, personalized analytical services to enable you to meet your analytical needs on time every time. We trust that you will find everything in order and to your satisfaction. If you have any questions, please do not hesitate to call me at (843) 556-8171, ext. 4504.
Our policy is to provide high quality, personalized analytical services to enable you to meet your analytical needs on time every time. We trust that you will find everything in order and to your satisfaction. If you have any questions, please do not hesitate to call me at (843) 556-8171, ext. 4504.
Sincerely, PM_SIGN_HERE Erin Trent Project Manager Purchase Order: 10287833 Enclosures
Sincerely, PM_SIGN_HERE Erin Trent Project Manager Purchase Order: 10287833 Enclosures  


Table of Contents Case Narrative......................................................................................1 Chain of Custody..................................................................................3 Laboratory Certifications......................................................................7 Radiological Analysis...........................................................................9 Case Narrative............................................................................10 Sample Data Summary...............................................................33 Quality Control Summary..........................................................37
Table of Contents Case Narrative......................................................................................1 Chain of Custody..................................................................................3 Laboratory Certifications......................................................................7 Radiological Analysis...........................................................................9 Case Narrative............................................................................10 Sample Data Summary...............................................................33 Quality Control Summary..........................................................37
Line 45: Line 44:
GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample Receipt The sample arrived at GEL Laboratories LLC, Charleston, South Carolina on April 21, 2016 for analysis. Chain of Custody form did not contain a relinquished signature. All sample containers arrived without any visible signs of tampering or breakage. There are no additional comments concerning sample receipt.
GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample Receipt The sample arrived at GEL Laboratories LLC, Charleston, South Carolina on April 21, 2016 for analysis. Chain of Custody form did not contain a relinquished signature. All sample containers arrived without any visible signs of tampering or breakage. There are no additional comments concerning sample receipt.
Sample Identification The laboratory received the following sample:
Sample Identification The laboratory received the following sample:
Laboratory ID       Client ID 395827001           Torus Water #2 Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL)
Laboratory ID Client ID 395827001 Torus Water #2 Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL)
Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.
Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.
Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, and data from the following fractions: Radiochemistry.
Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, and data from the following fractions: Radiochemistry.
Line 52: Line 51:
Chain of Custody Page 3 of 49
Chain of Custody Page 3 of 49


Page 4 of 49 Page 5 of 49 Page 6 of 49 Laboratory Certifications Page 7 of 49
Page 4 of 49
 
Page 5 of 49
 
Page 6 of 49


List of current GEL Certifications as of 26 April 2016 State                     Certification Alaska                     UST0110 Arkansas                     880651 CLIA                     42D0904046 California                       2940 Colorado                     SC00012 Connecticut                     PH0169 Delaware                     SC00012 DoD ELAP/ ISO17025 A2LA                   2567.01 Florida NELAP                       E87156 Foreign Soils Permit     P3301500283, P3301500253 Georgia                     SC00012 Georgia SDWA                         967 Hawaii                       SC00012 Idaho Chemistry                   SC00012 Idaho Radiochemistry                 SC00012 Illinois NELAP                     200029 Indiana                     CSC01 Kansas NELAP                       E10332 Kentucky SDWA                         90129 Kentucky Wastewater                     90129 Louisiana NELAP                 03046 (AI33904)
Laboratory Certifications Page 7 of 49
Louisiana SDWA                     LA160006 Maryland                         270 Massachusetts                   MSC012 Michigan                         9976 Mississippi                   SC00012 Nebraska                   NEOS2613 Nevada                   SC0001220161 New Hampshire NELAP                     205415 New Jersey NELAP                       SC002 New Mexico                     SC00012 New York NELAP                       11501 North Carolina                       233 North Carolina SDWA                     45709 North Dakota                       R158 Oklahoma                         9904 Pennsylvania NELAP                   6800485 S.Carolina Radchem                   10120002 South Carolina Chemistry               10120001 Tennessee                     TN 02934 Texas NELAP                 T1047042351611 Utah NELAP                   SC00012201620 Vermont                     VT87156 Virginia NELAP                     460202 Washington                         C780 West Virginia                     997404 Page 8 of 49
 
State Certification Alaska Arkansas CLIA California Colorado Connecticut Delaware DoD ELAP/ ISO17025 A2LA Florida NELAP Foreign Soils Permit Georgia Georgia SDWA Hawaii Idaho Chemistry Idaho Radiochemistry Illinois NELAP Indiana Kansas NELAP Kentucky SDWA Kentucky Wastewater Louisiana NELAP Louisiana SDWA Maryland Massachusetts Michigan Mississippi Nebraska Nevada New Hampshire NELAP New Jersey NELAP New Mexico New York NELAP North Carolina North Carolina SDWA North Dakota Oklahoma Pennsylvania NELAP S.Carolina Radchem South Carolina Chemistry Tennessee Texas NELAP Utah NELAP Vermont Virginia NELAP Washington West Virginia UST0110 880651 42D0904046 2940 SC00012 PH0169 SC00012 2567.01 E87156 P3301500283, P3301500253 SC00012 967 SC00012 SC00012 SC00012 200029 CSC01 E10332 90129 90129 03046 (AI33904)
LA160006 270 MSC012 9976 SC00012 NEOS2613 SC0001220161 205415 SC002 SC00012 11501 233 45709 R158 9904 6800485 10120002 10120001 TN 02934 T1047042351611 SC00012201620 VT87156 460202 C780 997404 List of current GEL Certifications as of 26 April 2016 Page 8 of 49


Radiological Analysis Page 9 of 49
Radiological Analysis Page 9 of 49
Line 62: Line 67:


Radiochemistry Technical Case Narrative Vermont Yankee, Entergy Nuclear Operations Inc. (NTRG)
Radiochemistry Technical Case Narrative Vermont Yankee, Entergy Nuclear Operations Inc. (NTRG)
SDG #: 395827 Method/Analysis Information Product:                       Alphaspec Pu242, Liquid Analytical Method:             DOE EML HASL-300, Pu-11-RC Modified Analytical Batch Number:       1562629 Sample ID       Client ID 395827001       Torus Water #2 1203535939     Method Blank (MB) 1203535941     Laboratory Control Sample (LCS) 1203535940     395827001(Torus Water #2) Sample Duplicate (DUP)
SDG #: 395827 Method/Analysis Information Product:
Alphaspec Pu242, Liquid Analytical Method:
DOE EML HASL-300, Pu-11-RC Modified Analytical Batch Number:
1562629 Sample ID Client ID 395827001 Torus Water #2 1203535939 Method Blank (MB) 1203535941 Laboratory Control Sample (LCS) 1203535940 395827001(Torus Water #2) Sample Duplicate (DUP)
The samples in this SDG were analyzed on an "as received" basis.
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 26.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 26.
Line 85: Line 93:
Additional Comments Additional comments were not required for this sample set.
Additional Comments Additional comments were not required for this sample set.
Qualifier Information Manual qualifiers were not required.
Qualifier Information Manual qualifiers were not required.
Method/Analysis Information Product:                     Alphaspec Am241, Cm, Liquid Analytical Method:           DOE EML HASL-300, Am-05-RC Modified Analytical Batch Number:     1562630 Sample ID       Client ID 395827001       Torus Water #2 1203535946       Method Blank (MB) 1203535948       Laboratory Control Sample (LCS) 1203535947       395827001(Torus Water #2) Sample Duplicate (DUP)
Method/Analysis Information Product:
Alphaspec Am241, Cm, Liquid Analytical Method:
DOE EML HASL-300, Am-05-RC Modified Analytical Batch Number:
1562630 Sample ID Client ID 395827001 Torus Water #2 1203535946 Method Blank (MB) 1203535948 Laboratory Control Sample (LCS) 1203535947 395827001(Torus Water #2) Sample Duplicate (DUP)
The samples in this SDG were analyzed on an "as received" basis.
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with Page 12 of 49
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with Page 12 of 49
Line 110: Line 121:
Page 13 of 49
Page 13 of 49


Method/Analysis Information Product:                       Alphaspec Np, Liquid Analytical Method:             ASTM C 1476-00 Modified Analytical Batch Number:       1562631 Sample ID       Client ID 395827001       Torus Water #2 1203535949     Method Blank (MB) 1203535951     Laboratory Control Sample (LCS) 1203535950     395827001(Torus Water #2) Sample Duplicate (DUP)
Method/Analysis Information Product:
Alphaspec Np, Liquid Analytical Method:
ASTM C 1476-00 Modified Analytical Batch Number:
1562631 Sample ID Client ID 395827001 Torus Water #2 1203535949 Method Blank (MB) 1203535951 Laboratory Control Sample (LCS) 1203535950 395827001(Torus Water #2) Sample Duplicate (DUP)
The samples in this SDG were analyzed on an "as received" basis.
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-032 REV# 20.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-032 REV# 20.
Line 133: Line 147:
Additional Comments Additional comments were not required for this sample set.
Additional Comments Additional comments were not required for this sample set.
Qualifier Information Manual qualifiers were not required.
Qualifier Information Manual qualifiers were not required.
Method/Analysis Information Product:                       Gammaspec, Gamma, Liquid (Standard List)
Method/Analysis Information Product:
Analytical Method:             EPA 901.1 Analytical Batch Number:       1561698 Sample ID       Client ID 395827001       Torus Water #2 1203533384     Method Blank (MB) 1203533386     Laboratory Control Sample (LCS) 1203533385     395827001(Torus Water #2) Sample Duplicate (DUP)
Gammaspec, Gamma, Liquid (Standard List)
Analytical Method:
EPA 901.1 Analytical Batch Number:
1561698 Sample ID Client ID 395827001 Torus Water #2 1203533384 Method Blank (MB) 1203533386 Laboratory Control Sample (LCS) 1203533385 395827001(Torus Water #2) Sample Duplicate (DUP)
The samples in this SDG were analyzed on an "as received" basis.
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 25.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 25.
Line 158: Line 175:
Method/Analysis Information Page 16 of 49
Method/Analysis Information Page 16 of 49


Product:                       Gamma I129, Liquid Analytical Method:             DOE EML HASL-300,I-01 Modified Analytical Batch Number:       1562602 Sample ID       Client ID 395827001       Torus Water #2 1203535843     Method Blank (MB) 1203535846     Laboratory Control Sample (LCS) 1203535844     395827001(Torus Water #2) Sample Duplicate (DUP) 1203535845     395827001(Torus Water #2) Matrix Spike (MS)
Product:
Gamma I129, Liquid Analytical Method:
DOE EML HASL-300,I-01 Modified Analytical Batch Number:
1562602 Sample ID Client ID 395827001 Torus Water #2 1203535843 Method Blank (MB) 1203535846 Laboratory Control Sample (LCS) 1203535844 395827001(Torus Water #2) Sample Duplicate (DUP) 1203535845 395827001(Torus Water #2) Matrix Spike (MS)
The samples in this SDG were analyzed on an "as received" basis.
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-006 REV# 21.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-006 REV# 21.
Line 180: Line 200:
Additional Comments Additional comments were not required for this sample set.
Additional Comments Additional comments were not required for this sample set.
Qualifier Information Manual qualifiers were not required.
Qualifier Information Manual qualifiers were not required.
Method/Analysis Information Product:                       Gamma Ni59, Liquid Analytical Method:             DOE RESL Ni-1 Analytical Batch Number:       1562693 Sample ID       Client ID 395827001       Torus Water #2 1203536149     Method Blank (MB) 1203536151     Laboratory Control Sample (LCS) 1203536150     395827001(Torus Water #2) Sample Duplicate (DUP)
Method/Analysis Information Product:
Gamma Ni59, Liquid Analytical Method:
DOE RESL Ni-1 Analytical Batch Number:
1562693 Sample ID Client ID 395827001 Torus Water #2 1203536149 Method Blank (MB) 1203536151 Laboratory Control Sample (LCS) 1203536150 395827001(Torus Water #2) Sample Duplicate (DUP)
The samples in this SDG were analyzed on an "as received" basis.
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 17.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 17.
Line 203: Line 226:
Additional Comments Additional comments were not required for this sample set.
Additional Comments Additional comments were not required for this sample set.
Qualifier Information Manual qualifiers were not required.
Qualifier Information Manual qualifiers were not required.
Method/Analysis Information Product:                       GFPC, Sr89&Sr90, Liquid Analytical Method:             EPA 905.0 Modified/DOE RP501 Rev. 1 Modified Analytical Batch Number:       1562716 Sample ID       Client ID Page 19 of 49
Method/Analysis Information Product:
GFPC, Sr89&Sr90, Liquid Analytical Method:
EPA 905.0 Modified/DOE RP501 Rev. 1 Modified Analytical Batch Number:
1562716 Sample ID Client ID Page 19 of 49


395827001       Torus Water #2 1203536197     Method Blank (MB) 1203536199     Laboratory Control Sample (LCS) 1203536198     395827001(Torus Water #2) Sample Duplicate (DUP)
395827001 Torus Water #2 1203536197 Method Blank (MB) 1203536199 Laboratory Control Sample (LCS) 1203536198 395827001(Torus Water #2) Sample Duplicate (DUP)
The samples in this SDG were analyzed on an "as received" basis.
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 17.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 17.
Line 228: Line 254:
Additional Comments Additional comments were not required for this sample set.
Additional Comments Additional comments were not required for this sample set.
Qualifier Information Manual qualifiers were not required.
Qualifier Information Manual qualifiers were not required.
Method/Analysis Information Product:                       Liquid Scint Pu241, Liquid Analytical Method:             DOE EML HASL-300, Pu-11-RC Modified Analytical Batch Number:       1562632 Sample ID       Client ID 395827001       Torus Water #2 1203535952     Method Blank (MB) 1203535954     Laboratory Control Sample (LCS) 1203535953     395827001(Torus Water #2) Sample Duplicate (DUP)
Method/Analysis Information Product:
Liquid Scint Pu241, Liquid Analytical Method:
DOE EML HASL-300, Pu-11-RC Modified Analytical Batch Number:
1562632 Sample ID Client ID 395827001 Torus Water #2 1203535952 Method Blank (MB) 1203535954 Laboratory Control Sample (LCS) 1203535953 395827001(Torus Water #2) Sample Duplicate (DUP)
The samples in this SDG were analyzed on an "as received" basis.
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 16.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 16.
Line 251: Line 280:
Additional Comments Additional comments were not required for this sample set.
Additional Comments Additional comments were not required for this sample set.
Qualifier Information Manual qualifiers were not required.
Qualifier Information Manual qualifiers were not required.
Method/Analysis Information Product:                     Liquid Scint Fe55, Liquid Analytical Method:           DOE RESL Fe-1, Modified Analytical Batch Number:     1562672 Sample ID       Client ID 395827001       Torus Water #2 1203536076     Method Blank (MB) 1203536078     Laboratory Control Sample (LCS) 1203536077     395827001(Torus Water #2) Sample Duplicate (DUP)
Method/Analysis Information Product:
Liquid Scint Fe55, Liquid Analytical Method:
DOE RESL Fe-1, Modified Analytical Batch Number:
1562672 Sample ID Client ID 395827001 Torus Water #2 1203536076 Method Blank (MB) 1203536078 Laboratory Control Sample (LCS) 1203536077 395827001(Torus Water #2) Sample Duplicate (DUP)
Page 22 of 49
Page 22 of 49


Line 275: Line 307:


Qualifier Information Manual qualifiers were not required.
Qualifier Information Manual qualifiers were not required.
Method/Analysis Information Product:                       Liquid Scint Ni63, Liquid Analytical Method:             DOE RESL Ni-1, Modified Analytical Batch Number:       1562678 Sample ID       Client ID 395827001       Torus Water #2 1203536092     Method Blank (MB) 1203536094     Laboratory Control Sample (LCS) 1203536093     395827001(Torus Water #2) Sample Duplicate (DUP)
Method/Analysis Information Product:
Liquid Scint Ni63, Liquid Analytical Method:
DOE RESL Ni-1, Modified Analytical Batch Number:
1562678 Sample ID Client ID 395827001 Torus Water #2 1203536092 Method Blank (MB) 1203536094 Laboratory Control Sample (LCS) 1203536093 395827001(Torus Water #2) Sample Duplicate (DUP)
The samples in this SDG were analyzed on an "as received" basis.
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 17.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 17.
Line 297: Line 332:
Additional Comments Additional comments were not required for this sample set.
Additional Comments Additional comments were not required for this sample set.
Qualifier Information Manual qualifiers were not required.
Qualifier Information Manual qualifiers were not required.
Method/Analysis Information Product:                     Liquid Scint Tc99, Liquid Analytical Method:           DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number:     1562683 Sample ID       Client ID 395827001       Torus Water #2 1203536111       Method Blank (MB) 1203536113       Laboratory Control Sample (LCS) 1203536112       395827001(Torus Water #2) Sample Duplicate (DUP)
Method/Analysis Information Product:
Liquid Scint Tc99, Liquid Analytical Method:
DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number:
1562683 Sample ID Client ID 395827001 Torus Water #2 1203536111 Method Blank (MB) 1203536113 Laboratory Control Sample (LCS) 1203536112 395827001(Torus Water #2) Sample Duplicate (DUP)
The samples in this SDG were analyzed on an "as received" basis.
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-059 REV# 4.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-059 REV# 4.
Line 322: Line 360:
Page 26 of 49
Page 26 of 49


Method/Analysis Information Product:                       LSC, Tritium Dist, Liquid Analytical Method:             EPA 906.0 Modified Analytical Batch Number:       1562687 Sample ID       Client ID 395827001       Torus Water #2 1203536126     Method Blank (MB) 1203536129     Laboratory Control Sample (LCS) 1203536127     395827001(Torus Water #2) Sample Duplicate (DUP) 1203536128     395827001(Torus Water #2) Matrix Spike (MS)
Method/Analysis Information Product:
LSC, Tritium Dist, Liquid Analytical Method:
EPA 906.0 Modified Analytical Batch Number:
1562687 Sample ID Client ID 395827001 Torus Water #2 1203536126 Method Blank (MB) 1203536129 Laboratory Control Sample (LCS) 1203536127 395827001(Torus Water #2) Sample Duplicate (DUP) 1203536128 395827001(Torus Water #2) Matrix Spike (MS)
The samples in this SDG were analyzed on an "as received" basis.
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 21.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 21.
Line 344: Line 385:
Additional Comments The matrix spike, 1203536128 (Torus Water #2MS), aliquot was reduced to conserve sample volume.
Additional Comments The matrix spike, 1203536128 (Torus Water #2MS), aliquot was reduced to conserve sample volume.
Qualifier Information Manual qualifiers were not required.
Qualifier Information Manual qualifiers were not required.
Method/Analysis Information Product:                       Liquid Scint C14, Liquid Analytical Method:             EPA EERF C-01 Modified Analytical Batch Number:       1562691 Sample ID       Client ID 395827001       Torus Water #2 1203536141     Method Blank (MB) 1203536144     Laboratory Control Sample (LCS) 1203536142     395827001(Torus Water #2) Sample Duplicate (DUP) 1203536143     395827001(Torus Water #2) Matrix Spike (MS)
Method/Analysis Information Product:
Liquid Scint C14, Liquid Analytical Method:
EPA EERF C-01 Modified Analytical Batch Number:
1562691 Sample ID Client ID 395827001 Torus Water #2 1203536141 Method Blank (MB) 1203536144 Laboratory Control Sample (LCS) 1203536142 395827001(Torus Water #2) Sample Duplicate (DUP) 1203536143 395827001(Torus Water #2) Matrix Spike (MS)
The samples in this SDG were analyzed on an "as received" basis.
The samples in this SDG were analyzed on an "as received" basis.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 15.
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 15.
Line 371: Line 415:


GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com VERM001 Vermont Yankee, Entergy Nuclear Operations Inc.
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com VERM001 Vermont Yankee, Entergy Nuclear Operations Inc.
Client SDG: 395827 GEL Work Order: 395827 Sample(s) Contained within this report:
Client SDG: 395827 GEL Work Order: 395827 Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
Lab Sample ID        Client Sample ID          Sample Description          Collected 395827001            Torus Water #2                  N/A            04/11/2016 09:10 Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Erin Trent.
This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Erin Trent.
Reviewed by Signature:                                                                 Name: Theresa Austin Date:   05 MAY 2016                                                        Title:  Group Leader Page 30 of 49
Reviewed by Sample(s) Contained within this report:
395827001 Lab Sample ID Client Sample ID Sample Description Torus Water #2 N/A Collected 04/11/2016 09:10 Signature:
Name:
Date:


GEL Laboratories LLC                                                                                        DER Report No.:       1513408 Form GEL-DER Revision No.: 1 DATA EXCEPTION REPORT Mo.Day Yr.                          Division:                     Quality Criteria:                    Type:
==Title:==
22-APR-16                           Radiochemistry                Specifications                        Process Instrument Type:                     Test / Method:                Matrix Type:                          Client Code:
05 MAY 2016 Theresa Austin Group Leader Page 30 of 49
GAMMA SPECTROMETER                   EPA 901.1                    Liquid                                VERM Batch ID:                           Sample Numbers:
 
1561698                              See Below Potentially affected work order(s)(SDG): 395827 Application Issues:
1513408 DER Report No.:
RDL less than MDA Specification and Requirements                                     DER Disposition:
1 Revision No.:
Exception
Spencer Collins Originator's Name:
22-APR-16 Shenise Gerideau Data Validator/Group Leader:
22-APR-16 Instrument Type:
Client Code:
Quality Criteria:
GAMMA SPECTROMETER Specifications VERM Type:
Process Division:
Radiochemistry Mo.Day Yr.
22-APR-16 GEL Laboratories LLC Form GEL-DER DATA EXCEPTION REPORT DER Disposition:
Samples did not meet the required detection limit due to high sample activity. Reporting results.
Specification and Requirements Exception


== Description:==
== Description:==
 
The following RDLs in sample 395827001 were not achieved: Cs-134, Fe-59, Nb-95 and Zr-95.
The following RDLs in sample 395827001 were not achieved: Cs-134, Samples did not meet the required detection limit due to high sample Fe-59, Nb-95 and Zr-95.                                          activity. Reporting results.
The following RDLs in DUP 1203533385 were not achieved: Cs-134, Fe-59, Nb-95 and Zr-95.
The following RDLs in DUP 1203533385 were not achieved: Cs-134, Fe-59, Nb-95 and Zr-95.
Originator's Name:                                                 Data Validator/Group Leader:
Application Issues:
Spencer Collins        22-APR-16                                  Shenise Gerideau          22-APR-16 Page 31 of 49
RDL less than MDA Batch ID:
1561698 Test / Method:
EPA 901.1 Liquid Matrix Type:
See Below Sample Numbers:
Potentially affected work order(s)(SDG):395827 Page 31 of 49


GEL Laboratories LLC                                                                                            DER Report No.:   1517546 Form GEL-DER Revision No.: 2 DATA EXCEPTION REPORT Mo.Day Yr.                            Division:                           Quality Criteria:                Type:
1517546 DER Report No.:
05-MAY-16                             Radiochemistry                      Specifications                  Process Instrument Type:                       Test / Method:                       Matrix Type:                     Client Code:
2 Revision No.:
LSC                                    DOE EML HASL-300, Tc-02-RC          Liquid                          VERM Modified Batch ID:                              Sample Numbers:
Elizabeth Krouse Originator's Name:
1562683                                See Below Potentially affected work order(s)(SDG): 395827 Application Issues:
05-MAY-16 Lyndsey Pace Data Validator/Group Leader:
Failed RPD for DUP Specification and Requirements                                             DER Disposition:
05-MAY-16 Instrument Type:
Exception
Client Code:
Quality Criteria:
LSC Specifications VERM Type:
Process Division:
Radiochemistry Mo.Day Yr.
05-MAY-16 GEL Laboratories LLC Form GEL-DER DATA EXCEPTION REPORT DER Disposition:
: 1. Reporting results.
Specification and Requirements Exception


== Description:==
== Description:==
: 1. Sample 395827001 and duplicate 1203536112 do not meet the relative     1. Reporting results.
: 1. Sample 395827001 and duplicate 1203536112 do not meet the relative percent difference requirement or the relative error ratio requirement due to the matrix of the sample.
percent difference requirement or the relative error ratio requirement due to the matrix of the sample.
Application Issues:
Originator's Name:                                                         Data Validator/Group Leader:
Failed RPD for DUP Batch ID:
Elizabeth Krouse        05-MAY-16                                          Lyndsey Pace          05-MAY-16 Page 32 of 49
1562683 Test / Method:
DOE EML HASL-300, Tc-02-RC Modified Liquid Matrix Type:
See Below Sample Numbers:
Potentially affected work order(s)(SDG):395827 Page 32 of 49


Sample Data Summary Page 33 of 49
Sample Data Summary Page 33 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com 10 CFR Part 50/61 Certificate of Analysis GEL Sample ID:        395827001                                                Client: Vermont Yankee, Entergy Nuclear Operatio Client Sample ID: Torus Water #2                                        Collect Date: April 11, 2016 Matrix:              Water                                            Receive Date: April      21, 2016 Geometry Received:                                                      Report Date: May        05, 2016 2
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Note(s): 1. Calculated MDAs are a-posteriori values at the 95% confidence level.
Analyte              Run Date      Qualifier        Activity    2 Sigma                    1 Uncertainty            MDA              RL            Units H-3                    04/29/16          3          1.70E+06    3.33E+04          1.75E+03        2.00E+03        pCi/L C-14                  05/03/16          U          1.49E+01    2.41E+01          4.08E+01        5.00E+01        pCi/L Fe-55                  04/28/16          3          9.53E+01    6.05E+01          8.07E+01        1.10E+02        pCi/L Ni-63                  04/29/16          3          7.94E+02    7.12E+01          7.04E+01        5.30E+02        pCi/L Sr-89                  05/02/16          U          1.08E+00    1.29E+00          2.18E+00        2.30E+01        pCi/L Sr-90                  05/02/16          U          3.31E-01    9.80E-01          2.66E+00        3.50E+00        pCi/L Tc-99                  05/03/16          3          3.89E+03    9.37E+01          4.26E+01        5.00E+01        pCi/L Pu-241                05/04/16          U          7.38E+00    1.13E+01          1.91E+01        2.50E+01        pCi/L Alpha Spec Np-237                04/30/16          U          -1.66E-01    3.14E-01          9.68E-01        1.50E+01        pCi/L Pu-238                05/02/16          U          1.96E-02    2.14E-01          4.50E-01        1.50E+01        pCi/L Pu-239/240            05/02/16          U          4.85E-02    2.13E-01          3.86E-01        1.50E+01        pCi/L Pu-242                05/02/16          U          1.91E-01    2.99E-01          4.10E-01        1.50E+01        pCi/L Am-241                04/30/16          U          4.31E-02    7.39E-02          6.47E-02        1.50E+01        pCi/L Cm-242                04/30/16          U          0.00E+00    4.66E-02          6.93E-02        1.50E+01        pCi/L Cm-243/244            04/30/16          U          -5.11E-03    4.41E-02          1.02E-01        1.50E+01        pCi/L Gamma Spec Be-7                  04/21/16          U          3.92E+01    9.40E+01          1.59E+02                          pCi/L Na-22                  04/21/16          U          6.07E+00    7.93E+00          1.35E+01                          pCi/L K-40                  04/21/16          U          1.14E+01    5.16E+01          8.56E+01                          pCi/L Cr-51                  04/21/16          U          3.07E+01    9.82E+01          1.69E+02                          pCi/L Mn-54                  04/21/16          3          4.71E+02    2.43E+01          2.38E+01        1.50E+01        pCi/L Fe-59                  04/21/16          U          2.87E+01    3.55E+01          6.01E+01        3.00E+01        pCi/L Co-56                  04/21/16          U          7.28E+00    1.52E+01          2.61E+01                          pCi/L Co-57                  04/21/16          U          3.24E+00    7.66E+00          1.28E+01                          pCi/L Co-58                  04/21/16          3          9.00E+01    2.06E+01          2.46E+01        1.50E+01        pCi/L Co-60                  04/21/16          3          2.07E+04    7.10E+01          1.26E+01        1.50E+01        pCi/L Ni-59                  04/28/16          U          5.85E+00    6.40E+00          1.01E+01        2.00E+01        pCi/L Zn-65                  04/21/16          3          1.95E+03    6.85E+01          5.59E+01        3.00E+01        pCi/L Y-88                  04/21/16          U          -1.32E+00    5.08E+00          8.67E+00                          pCi/L Zr-95                  04/21/16          U          2.37E+01    2.40E+01          4.17E+01        3.00E+01        pCi/L Nb-94                  04/21/16          U          -7.62E+00    1.13E+01          1.84E+01                          pCi/L Nb-95                  04/21/16          U          6.97E+00    1.34E+01          2.31E+01        1.50E+01        pCi/L Ru-106                04/21/16          U          3.19E+01    1.04E+02          1.72E+02                          pCi/L Ag-110m                04/21/16          U          -4.46E+00    2.14E+01          3.65E+01                          pCi/L Sn-113                04/21/16          U          9.02E+00    1.28E+01          2.19E+01                          pCi/L Note(s): 1. Calculated MDAs are a-posteriori values at the 95% confidence level.
: 2. Activity is reported on a dry weight basis unless otherwise indicated in the case narrativeand is decay corrected to the sample collect date.
: 2. Activity is reported on a dry weight basis unless otherwise indicated in the case narrativeand is decay corrected to the sample collect date.
: 3. Results are statistically positive at the 95% confidence level. (activity is greater than or equal to the two sigma uncertainty)
: 3. Results are statistically positive at the 95% confidence level. (activity is greater than or equal to the two sigma uncertainty)
U   Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.
U Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.
Page 34 of 49
10 CFR Part 50/61 Certificate of Analysis GEL Sample ID:
Matrix:
Geometry Received:
Client:
Collect Date:
Receive Date:
Client Sample ID:
395827001 Water Vermont Yankee, Entergy Nuclear Operatio April 11, 2016 April 21, 2016 Torus Water #2 Report Date: May 05, 2016 Analyte Run Date Activity MDA Qualifier 2 Sigma Uncertainty RL Alpha Spec Gamma Spec H-3 C-14 Fe-55 Ni-63 Sr-89 Sr-90 Tc-99 Pu-241 Np-237 Pu-238 Pu-239/240 Pu-242 Am-241 Cm-242 Cm-243/244 Be-7 Na-22 K-40 Cr-51 Mn-54 Fe-59 Co-56 Co-57 Co-58 Co-60 Ni-59 Zn-65 Y-88 Zr-95 Nb-94 Nb-95 Ru-106 Ag-110m Sn-113 04/29/16 05/03/16 04/28/16 04/29/16 05/02/16 05/02/16 05/03/16 05/04/16 04/30/16 05/02/16 05/02/16 05/02/16 04/30/16 04/30/16 04/30/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/28/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 1.70E+06 1.49E+01 9.53E+01 7.94E+02 1.08E+00 3.31E-01 3.89E+03 7.38E+00
-1.66E-01 1.96E-02 4.85E-02 1.91E-01 4.31E-02 0.00E+00
-5.11E-03 3.92E+01 6.07E+00 1.14E+01 3.07E+01 4.71E+02 2.87E+01 7.28E+00 3.24E+00 9.00E+01 2.07E+04 5.85E+00 1.95E+03
-1.32E+00 2.37E+01
-7.62E+00 6.97E+00 3.19E+01
-4.46E+00 9.02E+00 3.33E+04 2.41E+01 6.05E+01 7.12E+01 1.29E+00 9.80E-01 9.37E+01 1.13E+01 3.14E-01 2.14E-01 2.13E-01 2.99E-01 7.39E-02 4.66E-02 4.41E-02 9.40E+01 7.93E+00 5.16E+01 9.82E+01 2.43E+01 3.55E+01 1.52E+01 7.66E+00 2.06E+01 7.10E+01 6.40E+00 6.85E+01 5.08E+00 2.40E+01 1.13E+01 1.34E+01 1.04E+02 2.14E+01 1.28E+01 1.75E+03 4.08E+01 8.07E+01 7.04E+01 2.18E+00 2.66E+00 4.26E+01 1.91E+01 9.68E-01 4.50E-01 3.86E-01 4.10E-01 6.47E-02 6.93E-02 1.02E-01 1.59E+02 1.35E+01 8.56E+01 1.69E+02 2.38E+01 6.01E+01 2.61E+01 1.28E+01 2.46E+01 1.26E+01 1.01E+01 5.59E+01 8.67E+00 4.17E+01 1.84E+01 2.31E+01 1.72E+02 3.65E+01 2.19E+01 2.00E+03 5.00E+01 1.10E+02 5.30E+02 2.30E+01 3.50E+00 5.00E+01 2.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 3.00E+01 1.50E+01 1.50E+01 2.00E+01 3.00E+01 3.00E+01 1.50E+01 3
U 3
3 U
U 3
U U
U U
U U
U U
U U
U U
3 U
U U
3 3
U 3
U U
U U
U U
U 1
2 pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Units Page 34 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com 10 CFR Part 50/61 Certificate of Analysis GEL Sample ID:        395827001                                                Client: Vermont Yankee, Entergy Nuclear Operatio Client Sample ID: Torus Water #2                                        Collect Date: April 11, 2016 Matrix:              Water                                            Receive Date: April      21, 2016 Geometry Received:                                                      Report Date: May        05, 2016 2
GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Note(s): 1. Calculated MDAs are a-posteriori values at the 95% confidence level.
Analyte            Run Date      Qualifier        Activity    2 Sigma                  1 Uncertainty            MDA              RL            Units Sb-124                04/21/16          U          -3.65E+00    1.09E+01          1.88E+01                          pCi/L Sb-125                04/21/16          U          8.30E+00    2.74E+01          4.64E+01                          pCi/L I-129                  04/27/16          U          -3.73E-02    8.59E-01          1.51E+00        2.00E+00        pCi/L Cs-134                04/21/16          U          -1.30E+01    1.47E+01          2.52E+01        1.50E+01        pCi/L Cs-136                04/21/16          U          5.93E+00    3.45E+01          5.84E+01                          pCi/L Cs-137                04/21/16          3          1.13E+03    2.43E+01          2.06E+01        1.80E+01        pCi/L Ba-133                04/21/16          U          -7.26E+00    1.32E+01          2.09E+01                          pCi/L Ba-140                04/21/16          U          -1.12E+01    6.57E+01          1.10E+02                          pCi/L Ce-139                04/21/16          U          -8.99E+00    8.66E+00          1.42E+01                          pCi/L Ce-141                04/21/16          U          -9.12E+00    1.67E+01          2.77E+01                          pCi/L Ce-144                04/21/16          U          3.42E+01    5.98E+01          9.96E+01                          pCi/L Nd-147                04/21/16          U          -8.63E+01    1.33E+02          2.22E+02                          pCi/L Pm-144                04/21/16          U          1.21E+00    1.14E+01          1.88E+01                          pCi/L Pm-146                04/21/16          U          4.46E+00    1.29E+01          2.19E+01                          pCi/L Eu-152                04/21/16          U          1.35E+01    2.86E+01          4.91E+01                          pCi/L Eu-154                04/21/16          U          1.78E+01    2.25E+01          3.83E+01                          pCi/L Eu-155                04/21/16          U          1.43E+01    3.04E+01          5.10E+01                          pCi/L Ir-192                04/21/16          U          -2.79E+00    9.96E+00          1.71E+01                          pCi/L Hg-203                04/21/16          U          8.62E+00    1.07E+01          1.86E+01                          pCi/L Tl-208                04/21/16          U          8.75E+00    1.20E+01          1.91E+01                          pCi/L Pb-210                04/21/16          U          9.04E+02    1.07E+03          1.84E+03                          pCi/L Pb-212                04/21/16          U          -1.47E+00    1.92E+01          3.09E+01                          pCi/L Pb-214                04/21/16          U          -6.77E+00    2.15E+01          3.65E+01                          pCi/L Bi-212                04/21/16          U          -6.90E+01    1.77E+02          2.89E+02                          pCi/L Bi-214                04/21/16          U          -1.64E+00    2.21E+01          3.64E+01                          pCi/L Ra-228                04/21/16          U          4.22E+01    6.30E+01          1.08E+02                          pCi/L Ac-228                04/21/16          U          4.22E+01    6.30E+01          1.08E+02                          pCi/L Th-234                04/21/16        3,U          3.77E+02    3.56E+02          5.78E+02                          pCi/L U-235                  04/21/16          U          -3.80E+01    5.95E+01          9.77E+01                          pCi/L U-238                  04/21/16        3,U          3.77E+02    3.56E+02          5.78E+02                          pCi/L Np-239                04/21/16          U          7.01E+01    7.43E+01          1.32E+02                          pCi/L Am-241                04/21/16          U          -2.43E+01    4.16E+01          7.09E+01                          pCi/L Note(s): 1. Calculated MDAs are a-posteriori values at the 95% confidence level.
: 2. Activity is reported on a dry weight basis unless otherwise indicated in the case narrativeand is decay corrected to the sample collect date.
: 2. Activity is reported on a dry weight basis unless otherwise indicated in the case narrativeand is decay corrected to the sample collect date.
: 3. Results are statistically positive at the 95% confidence level. (activity is greater than or equal to the two sigma uncertainty)
: 3. Results are statistically positive at the 95% confidence level. (activity is greater than or equal to the two sigma uncertainty)
U   Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.
U Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.
Page 35 of 49
10 CFR Part 50/61 Certificate of Analysis GEL Sample ID:
Matrix:
Geometry Received:
Client:
Collect Date:
Receive Date:
Client Sample ID:
395827001 Water Vermont Yankee, Entergy Nuclear Operatio April 11, 2016 April 21, 2016 Torus Water #2 Report Date: May 05, 2016 Analyte Run Date Activity MDA Qualifier 2 Sigma Uncertainty RL Sb-124 Sb-125 I-129 Cs-134 Cs-136 Cs-137 Ba-133 Ba-140 Ce-139 Ce-141 Ce-144 Nd-147 Pm-144 Pm-146 Eu-152 Eu-154 Eu-155 Ir-192 Hg-203 Tl-208 Pb-210 Pb-212 Pb-214 Bi-212 Bi-214 Ra-228 Ac-228 Th-234 U-235 U-238 Np-239 Am-241 04/21/16 04/21/16 04/27/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16
-3.65E+00 8.30E+00
-3.73E-02
-1.30E+01 5.93E+00 1.13E+03
-7.26E+00
-1.12E+01
-8.99E+00
-9.12E+00 3.42E+01
-8.63E+01 1.21E+00 4.46E+00 1.35E+01 1.78E+01 1.43E+01
-2.79E+00 8.62E+00 8.75E+00 9.04E+02
-1.47E+00
-6.77E+00
-6.90E+01
-1.64E+00 4.22E+01 4.22E+01 3.77E+02
-3.80E+01 3.77E+02 7.01E+01
-2.43E+01 1.09E+01 2.74E+01 8.59E-01 1.47E+01 3.45E+01 2.43E+01 1.32E+01 6.57E+01 8.66E+00 1.67E+01 5.98E+01 1.33E+02 1.14E+01 1.29E+01 2.86E+01 2.25E+01 3.04E+01 9.96E+00 1.07E+01 1.20E+01 1.07E+03 1.92E+01 2.15E+01 1.77E+02 2.21E+01 6.30E+01 6.30E+01 3.56E+02 5.95E+01 3.56E+02 7.43E+01 4.16E+01 1.88E+01 4.64E+01 1.51E+00 2.52E+01 5.84E+01 2.06E+01 2.09E+01 1.10E+02 1.42E+01 2.77E+01 9.96E+01 2.22E+02 1.88E+01 2.19E+01 4.91E+01 3.83E+01 5.10E+01 1.71E+01 1.86E+01 1.91E+01 1.84E+03 3.09E+01 3.65E+01 2.89E+02 3.64E+01 1.08E+02 1.08E+02 5.78E+02 9.77E+01 5.78E+02 1.32E+02 7.09E+01 2.00E+00 1.50E+01 1.80E+01 U
U U
U U
3 U
U U
U U
U U
U U
U U
U U
U U
U U
U U
U U
3,U U
3,U U
U 1
2 pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Units Page 35 of 49


GEL LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com 10 CFR Part 50/61 Isotope Abundance Report GEL Sample ID:     395827001                                      Client: Vermont Yankee, Entergy Nuclear Operations Inc.
GEL LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com 10 CFR Part 50/61 Isotope Abundance Report GEL Sample ID:
Client Sample ID: Torus Water #2                          Collect Date: April   11, 2016 Matrix:            Water                                  Receive Date: April   21, 2016 Analyte                           Activity       Units    % Abundance Ni-63                               7.94E+02       pCi/L          000.05 Tc-99                              3.89E+03       pCi/L          000.22 H-3                                1.70E+06       pCi/L          098.31 Alpha Spec Gamma Spec Cs-137                              1.13E+03       pCi/L          000.07 Co-60                              2.07E+04       pCi/L          001.20 Mn-54                              4.71E+02       pCi/L          000.03 Zn-65                              1.95E+03       pCi/L         000.11 Total Activity:     1.73E+06 Total % Abundance:       100.00 Page 36 of 49
Matrix:
Client:
Collect Date:
Receive Date:
Client Sample ID:
395827001 Water Vermont Yankee, Entergy Nuclear Operations Inc.
April 11, 2016 April 21, 2016 Torus Water #2 Analyte Activity Alpha Spec Gamma Spec Ni-63 Tc-99 H-3 Cs-137 Co-60 Mn-54 Zn-65 7.94E+02 3.89E+03 1.70E+06 1.13E+03 2.07E+04 4.71E+02 1.95E+03 pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Units
% Abundance 000.05 000.22 098.31 000.07 001.20 000.03 000.11 Total Activity:
1.73E+06 Total % Abundance:
100.00 Page 36 of 49


Quality Control Summary Page 37 of 49
Quality Control Summary Page 37 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com QC Summary                      Report Date: May 5, 2016 Entergy Nuclear Operations, Inc., VY                                                                       Page 1 of 12 530 Governor Hunt Road PO Box 250 Vernon, Vermont Contact:         Mr. Mark Vandale Workorder:      395827 Parmname                                NOM            Sample Qual      QC  Units   RPD%      REC%      Range    Anlst  Date Time Rad Alpha Spec Batch          1562629 QC1203535940  395827001 DUP Plutonium-238                                      U    0.0196 U        0.132  pCi/L     N/A                    N/A MXS2 04/30/16 11:03 Uncertainty    +/-0.214      +/-0.142 Plutonium-239/240                                  U    0.0485 U      0.0824  pCi/L    N/A                    N/A Uncertainty    +/-0.213      +/-0.113 Plutonium-242                                      U      0.191 U      0.0763  pCi/L    N/A                   N/A Uncertainty    +/-0.299      +/-0.113 QC1203535941    LCS Plutonium-238                                                    U     0.0475  pCi/L                                      04/30/16 11:03 Uncertainty                    +/-0.107 Plutonium-239/240                      4.94                             5.71  pCi/L              116  (75%-125%)
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Alpha Spec 1562629 1562630 Batch Batch Plutonium-238 Plutonium-239/240 Plutonium-242 Plutonium-238 Plutonium-239/240 Plutonium-242 Plutonium-238 Plutonium-239/240 Plutonium-242 Americium-241 Curium-242 Curium-243/244 Americium-241 Curium-242 Curium-243/244 Americium-241 Curium-242 Parmname Mr. Mark Vandale
Uncertainty                    +/-0.770 Plutonium-242                                                    U      0.0545  pCi/L Uncertainty                    +/-0.108 QC1203535939    MB Plutonium-238                                                    U      0.0605  pCi/L                                      04/30/16 11:05 Uncertainty                  +/-0.0977 Plutonium-239/240                                                U    -0.0135    pCi/L Uncertainty                  +/-0.0611 Plutonium-242                                                    U      0.0215  pCi/L Uncertainty                  +/-0.0828 Batch          1562630 QC1203535947  395827001 DUP Americium-241                                      U    0.0431        0.0765  pCi/L    16.6                  N/A MXS2 04/30/16 11:05 Uncertainty    +/-0.0739      +/-0.101 Curium-242                                        U        0.00 U        0.00  pCi/L    N/A                    N/A Uncertainty    +/-0.0466      +/-0.055 Curium-243/244                                    U  -0.00511 U        0.0252  pCi/L    N/A                    N/A Uncertainty    +/-0.0441    +/-0.0707 QC1203535948    LCS Americium-241                          4.93                              5.27  pCi/L              107  (75%-125%)        04/30/16 11:08 Uncertainty                    +/-0.623 Curium-242                                                      U      0.0144  pCi/L Uncertainty                  +/-0.0539 Curium-243/244                          6.61                              6.22  pCi/L            94.1  (75%-125%)
 
Uncertainty                    +/-0.671 QC1203535946    MB Americium-241                                                    U      0.0246  pCi/L                                      04/30/16 11:05 Uncertainty                  +/-0.0949 Curium-242                                                      U  -0.00542    pCi/L Uncertainty                  +/-0.0468 Page 38 of 49
==Contact:==
Entergy Nuclear Operations, Inc., VY 530 Governor Hunt Road Vernon, Vermont May 5, 2016 Report Date:
Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MXS2 MXS2 04/30/16 11:03 04/30/16 11:03 04/30/16 11:05 04/30/16 11:05 04/30/16 11:08 04/30/16 11:05 QC 0.132 0.0824 0.0763 0.0475 5.71 0.0545 0.0605
-0.0135 0.0215 0.0765 0.00 0.0252 5.27 0.0144 6.22 0.0246
-0.00542 NOM Sample 0.0196 0.0485 0.191 0.0431 0.00
-0.00511 Range N/A N/A N/A (75%-125%)
N/A N/A N/A (75%-125%)
(75%-125%)
Qual U
U U
U U
U U
U U
U U
U U
QC1203535940 395827001 QC1203535941 QC1203535939 QC1203535947 395827001 QC1203535948 QC1203535946 N/A N/A N/A 16.6 N/A N/A REC%
116 107 94.1 4.94 4.93 6.61 DUP LCS MB DUP LCS MB 395827 Workorder:
PO Box 250 U
U U
U U
U
+/-0.214
+/-0.213
+/-0.299
+/-0.0739
+/-0.0466
+/-0.0441
+/-0.142
+/-0.113
+/-0.113
+/-0.107
+/-0.770
+/-0.108
+/-0.0977
+/-0.0611
+/-0.0828
+/-0.101
+/-0.055
+/-0.0707
+/-0.623
+/-0.0539
+/-0.671
+/-0.0949
+/-0.0468 RPD%
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 1 of 12 Page 38 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:      395827                                                                                                Page 2 of 12 Parmname                              NOM        Sample Qual          QC    Units    RPD%      REC%    Range  Anlst  Date Time Rad Alpha Spec Batch         1562630 Curium-243/244                                             U      0.00629      pCi/L Uncertainty                +/-0.0657 Batch          1562631 QC1203535950  395827001 DUP Neptunium-237                                 U  -0.166  U        0.225    pCi/L     N/A                  N/A MXS2 04/30/16 10:57 Uncertainty  +/-0.314        +/-0.654 QC1203535951    LCS Neptunium-237                      89.3                              91.8    pCi/L              103 (75%-125%)      04/30/16 10:59 Uncertainty                    +/-6.94 QC1203535949    MB Neptunium-237                                              U        0.0941    pCi/L                                  04/30/16 10:57 Uncertainty                  +/-0.422 Batch          1562632 QC1203535953  395827001 DUP Plutonium-241                                U      7.38 U        -1.65    pCi/L    N/A                  N/A MXS2 05/04/16 15:25 Uncertainty  +/-11.3          +/-7.13 QC1203535954    LCS Plutonium-241                        194                              216    pCi/L              111 (75%-125%)      05/03/16 14:19 Uncertainty                    +/-27.4 QC1203535952    MB Plutonium-241                                              U          -1.4    pCi/L                                  05/04/16 13:54 Uncertainty                    +/-7.62 Rad Gamma Spec Batch          1561698 QC1203533385  395827001 DUP Actinium-228                                  U      42.2 U        -83.9     pCi/L    N/A                  N/A MJH1 04/22/16 06:34 Uncertainty  +/-63.0         +/-95.8 Americium-241                                U    -24.3 U        -30.2     pCi/L    N/A                 N/A Uncertainty  +/-41.6          +/-50.5 Antimony-124                                  U    -3.65  U          1.84    pCi/L    N/A                 N/A Uncertainty  +/-10.9          +/-15.8 Antimony-125                                  U       8.30 U         -5.76    pCi/L    N/A                 N/A Uncertainty  +/-27.4          +/-41.9 Barium-133                                    U    -7.26  U        -11.2    pCi/L    N/A                 N/A Uncertainty  +/-13.2          +/-20.8 Barium-140                                    U    -11.2  U          55.0     pCi/L    N/A                  N/A Uncertainty  +/-65.7          +/-103 Beryllium-7                                  U      39.2 U          51.4    pCi/L    N/A                  N/A Uncertainty  +/-94.0         +/-144 Bismuth-212                                  U      -69  U          27.2    pCi/L    N/A                  N/A Uncertainty    +/-177          +/-257 Bismuth-214                                  U    -1.64  U          1.58    pCi/L    N/A                  N/A Uncertainty  +/-22.1          +/-34.0 Cerium-139                                    U    -8.99  U          1.86    pCi/L    N/A                  N/A Uncertainty  +/-8.66          +/-12.7 Page 39 of 49
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Alpha Spec Rad Gamma Spec 1562630 1562631 1562632 1561698 Batch Batch Batch Batch Curium-243/244 Neptunium-237 Neptunium-237 Neptunium-237 Plutonium-241 Plutonium-241 Plutonium-241 Actinium-228 Americium-241 Antimony-124 Antimony-125 Barium-133 Barium-140 Beryllium-7 Bismuth-212 Bismuth-214 Cerium-139 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MXS2 MXS2 MJH1 04/30/16 10:57 04/30/16 10:59 04/30/16 10:57 05/04/16 15:25 05/03/16 14:19 05/04/16 13:54 04/22/16 06:34 QC 0.00629 0.225 91.8 0.0941
-1.65 216
-1.4
-83.9
-30.2 1.84
-5.76
-11.2 55.0 51.4 27.2 1.58 1.86 NOM Sample
-0.166 7.38 42.2
-24.3
-3.65 8.30
-7.26
-11.2 39.2
-69
-1.64
-8.99 Range N/A (75%-125%)
N/A (75%-125%)
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Qual U
U U
U U
U U
U U
U U
U U
U U
QC1203535950 395827001 QC1203535951 QC1203535949 QC1203535953 395827001 QC1203535954 QC1203535952 QC1203533385 395827001 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A REC%
103 111 89.3 194 DUP LCS MB DUP LCS MB DUP 395827 Workorder:
U U
U U
U U
U U
U U
U U
+/-0.314
+/-11.3
+/-63.0
+/-41.6
+/-10.9
+/-27.4
+/-13.2
+/-65.7
+/-94.0
+/-177
+/-22.1
+/-8.66
+/-0.0657
+/-0.654
+/-6.94
+/-0.422
+/-7.13
+/-27.4
+/-7.62
+/-95.8
+/-50.5
+/-15.8
+/-41.9
+/-20.8
+/-103
+/-144
+/-257
+/-34.0
+/-12.7 RPD%
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 2 of 12 Page 39 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:      395827                                                                                        Page 3 of 12 Parmname                    NOM        Sample Qual          QC    Units    RPD%      REC%    Range    Anlst  Date Time Rad Gamma Spec Batch         1561698 Cerium-141                         U    -9.12  U          -12    pCi/L     N/A                  N/A Uncertainty  +/-16.7        +/-24.6 Cerium-144                          U      34.2  U          16.8    pCi/L     N/A                  N/A MJH1 04/22/16 06:34 Uncertainty  +/-59.8         +/-87.5 Cesium-134                          U      -13  U        -8.32      pCi/L    N/A                  N/A Uncertainty  +/-14.7         +/-22.6 Cesium-136                          U      5.93  U        -39.4      pCi/L    N/A                  N/A Uncertainty  +/-34.5         +/-53.9 Cesium-137                                1130           1150      pCi/L    2.28           (0%-20%)
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698 Batch Cerium-141 Cerium-144 Cesium-134 Cesium-136 Cesium-137 Chromium-51 Cobalt-56 Cobalt-57 Cobalt-58 Cobalt-60 Europium-152 Europium-154 Europium-155 Iridium-192 Iron-59 Lead-210 Lead-212 Lead-214 Manganese-54 Mercury-203 Neodymium-147 Neptunium-239 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 04/22/16 06:34 QC
Uncertainty  +/-24.3        +/-36.7 Chromium-51                        U      30.7  U          3.78    pCi/L    N/A                   N/A Uncertainty  +/-98.2          +/-147 Cobalt-56                          U      7.28  U          5.84    pCi/L    N/A                   N/A Uncertainty  +/-15.2        +/-23.3 Cobalt-57                          U      3.24  U          6.90    pCi/L    N/A                   N/A Uncertainty  +/-7.66        +/-12.0 Cobalt-58                                  90.0            89.1    pCi/L  0.982          (0% - 100%)
-12 16.8
Uncertainty  +/-20.6        +/-28.7 Cobalt-60                                20700            20400      pCi/L    1.55          (0%-20%)
-8.32
Uncertainty  +/-71.0          +/-103 Europium-152                        U     13.5  U       -7.81      pCi/L    N/A                   N/A Uncertainty  +/-28.6        +/-42.7 Europium-154                        U      17.8  U          17.7    pCi/L    N/A                   N/A Uncertainty  +/-22.5        +/-31.6 Europium-155                        U      14.3  U          20.9    pCi/L    N/A                   N/A Uncertainty  +/-30.4        +/-44.2 Iridium-192                        U    -2.79  U        -2.06      pCi/L    N/A                  N/A Uncertainty  +/-9.96        +/-15.4 Iron-59                            U      28.7  U        -55.9      pCi/L    N/A                  N/A Uncertainty  +/-35.5         +/-53.1 Lead-210                            U      904  U        -414      pCi/L    N/A                  N/A Uncertainty  +/-1070          +/-1020 Lead-212                            U    -1.47  U        0.365    pCi/L    N/A                  N/A Uncertainty  +/-19.2         +/-26.2 Lead-214                            U    -6.77  U          7.39    pCi/L    N/A                  N/A Uncertainty  +/-21.5         +/-32.0 Manganese-54                                471              481    pCi/L    1.95          (0%-20%)
-39.4 1150 3.78 5.84 6.90 89.1 20400
Uncertainty  +/-24.3         +/-36.4 Mercury-203                        U      8.62  U        0.957    pCi/L    N/A                  N/A Uncertainty  +/-10.7         +/-15.9 Neodymium-147                      U    -86.3  U        -52.1     pCi/L    N/A                  N/A Uncertainty  +/-133          +/-208 Neptunium-239                      U      70.1  U        -65.9     pCi/L    N/A                  N/A Uncertainty  +/-74.3          +/-115 Page 40 of 49
-7.81 17.7 20.9
-2.06
-55.9
-414 0.365 7.39 481 0.957
-52.1
-65.9 NOM Sample
-9.12 34.2
-13 5.93 1130 30.7 7.28 3.24 90.0 20700 13.5 17.8 14.3
-2.79 28.7 904
-1.47
-6.77 471 8.62
-86.3 70.1 Range N/A N/A N/A N/A (0%-20%)
N/A N/A N/A (0% - 100%)
(0%-20%)
N/A N/A N/A N/A N/A N/A N/A N/A (0%-20%)
N/A N/A N/A Qual U
U U
U U
U U
U U
U U
U U
U U
U U
U N/A N/A N/A N/A 2.28 N/A N/A N/A 0.982 1.55 N/A N/A N/A N/A N/A N/A N/A N/A 1.95 N/A N/A N/A REC%
395827 Workorder:
U U
U U
U U
U U
U U
U U
U U
U U
U U
+/-16.7
+/-59.8
+/-14.7
+/-34.5
+/-24.3
+/-98.2
+/-15.2
+/-7.66
+/-20.6
+/-71.0
+/-28.6
+/-22.5
+/-30.4
+/-9.96
+/-35.5
+/-1070
+/-19.2
+/-21.5
+/-24.3
+/-10.7
+/-133
+/-74.3
+/-24.6
+/-87.5
+/-22.6
+/-53.9
+/-36.7
+/-147
+/-23.3
+/-12.0
+/-28.7
+/-103
+/-42.7
+/-31.6
+/-44.2
+/-15.4
+/-53.1
+/-1020
+/-26.2
+/-32.0
+/-36.4
+/-15.9
+/-208
+/-115 RPD%
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 3 of 12 Page 40 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:      395827                                                                                        Page 4 of 12 Parmname                      NOM        Sample Qual          QC    Units    RPD%      REC%    Range  Anlst  Date Time Rad Gamma Spec Batch         1561698 Niobium-94                           U    -7.62  U          14.9    pCi/L     N/A                  N/A Uncertainty  +/-11.3        +/-16.4 Niobium-95                            U      6.97  U          22.9    pCi/L     N/A                  N/A MJH1 04/22/16 06:34 Uncertainty  +/-13.4         +/-23.5 Potassium-40                          U      11.4 U          16.1     pCi/L    N/A                 N/A Uncertainty  +/-51.6        +/-69.1 Promethium-144                        U      1.21  U          1.11    pCi/L    N/A                 N/A Uncertainty  +/-11.4        +/-16.5 Promethium-146                        U      4.46  U        -18.9      pCi/L    N/A                 N/A Uncertainty  +/-12.9        +/-19.7 Radium-228                            U     42.2  U       -83.9      pCi/L    N/A                 N/A Uncertainty  +/-63.0        +/-95.8 Ruthenium-106                        U      31.9  U          136    pCi/L    N/A                 N/A Uncertainty  +/-104          +/-159 Silver-110m                          U    -4.46  U          40.9    pCi/L    N/A                 N/A Uncertainty  +/-21.4        +/-33.1 Sodium-22                            U      6.07  U          6.22    pCi/L    N/A                 N/A Uncertainty  +/-7.93        +/-11.1 Thallium-208                          U      8.75  U        -15.1      pCi/L    N/A                  N/A Uncertainty  +/-12.0        +/-19.0 Thorium-234                          U      377  U          155    pCi/L    N/A                  N/A Uncertainty  +/-356           +/-425 Tin-113                              U      9.02  U        0.622    pCi/L    N/A                  N/A Uncertainty  +/-12.8        +/-19.4 Uranium-235                          U      -38  U          16.4     pCi/L    N/A                  N/A Uncertainty  +/-59.5         +/-85.7 Uranium-238                          U      377  U          155    pCi/L    N/A                  N/A Uncertainty  +/-356          +/-425 Yttrium-88                            U    -1.32  U        -5.55      pCi/L    N/A                  N/A Uncertainty  +/-5.08        +/-7.20 Zinc-65                                      1950            1870      pCi/L    3.98          (0%-20%)
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698 Batch Niobium-94 Niobium-95 Potassium-40 Promethium-144 Promethium-146 Radium-228 Ruthenium-106 Silver-110m Sodium-22 Thallium-208 Thorium-234 Tin-113 Uranium-235 Uranium-238 Yttrium-88 Zinc-65 Zirconium-95 Actinium-228 Americium-241 Antimony-124 Antimony-125 Barium-133 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 04/22/16 06:34 04/22/16 06:39 QC 14.9 22.9 16.1 1.11
Uncertainty  +/-68.5        +/-96.7 Zirconium-95                          U      23.7 U        -5.38      pCi/L    N/A                  N/A Uncertainty  +/-24.0        +/-36.8 QC1203533386    LCS Actinium-228                                      U          122    pCi/L                                  04/22/16 06:39 Uncertainty                    +/-399 Americium-241              34400                            39700      pCi/L              115 (75%-125%)
-18.9
Uncertainty                  +/-1740 Antimony-124                                      U          15.9    pCi/L Uncertainty                  +/-46.1 Antimony-125                                      U        -157      pCi/L Uncertainty                    +/-241 Barium-133                                        U          27.6    pCi/L Uncertainty Page 41 of 49
-83.9 136 40.9 6.22
-15.1 155 0.622 16.4 155
-5.55 1870
-5.38 122 39700 15.9
-157 27.6 NOM Sample
-7.62 6.97 11.4 1.21 4.46 42.2 31.9
-4.46 6.07 8.75 377 9.02
-38 377
-1.32 1950 23.7 Range N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (0%-20%)
N/A (75%-125%)
Qual U
U U
U U
U U
U U
U U
U U
U U
U U
U U
U QC1203533386 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 3.98 N/A REC%
115 34400 LCS 395827 Workorder:
U U
U U
U U
U U
U U
U U
U U
U U
+/-11.3
+/-13.4
+/-51.6
+/-11.4
+/-12.9
+/-63.0
+/-104
+/-21.4
+/-7.93
+/-12.0
+/-356
+/-12.8
+/-59.5
+/-356
+/-5.08
+/-68.5
+/-24.0
+/-16.4
+/-23.5
+/-69.1
+/-16.5
+/-19.7
+/-95.8
+/-159
+/-33.1
+/-11.1
+/-19.0
+/-425
+/-19.4
+/-85.7
+/-425
+/-7.20
+/-96.7
+/-36.8
+/-399
+/-1740
+/-46.1
+/-241 RPD%
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 4 of 12 Page 41 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:    395827                                                                                        Page 5 of 12 Parmname                  NOM        Sample Qual          QC    Units    RPD%      REC%    Range  Anlst  Date Time Rad Gamma Spec Batch       1561698
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698 Batch Barium-140 Beryllium-7 Bismuth-212 Bismuth-214 Cerium-139 Cerium-141 Cerium-144 Cesium-134 Cesium-136 Cesium-137 Chromium-51 Cobalt-56 Cobalt-57 Cobalt-58 Cobalt-60 Europium-152 Europium-154 Europium-155 Iridium-192 Iron-59 Lead-210 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 04/22/16 06:39 QC 153
                                                          +/-103 Barium-140                                     U            153    pCi/L                             MJH1 04/22/16 06:39 Uncertainty                    +/-282 Beryllium-7                                    U          -119    pCi/L Uncertainty                    +/-768 Bismuth-212                                    U            540    pCi/L Uncertainty                  +/-1080 Bismuth-214                                    U          -68.5    pCi/L Uncertainty                    +/-142 Cerium-139                                    U            43.7    pCi/L Uncertainty                    +/-66.4 Cerium-141                                    U          -75.7    pCi/L Uncertainty                    +/-112 Cerium-144                                    U          -268    pCi/L Uncertainty                    +/-478 Cesium-134                                    U            23.7   pCi/L Uncertainty                    +/-94.4 Cesium-136                                    U          -66.4     pCi/L Uncertainty                    +/-158 Cesium-137              13500                            13700    pCi/L              102 (75%-125%)
-119 540
Uncertainty                    +/-354 Chromium-51                                    U          -199    pCi/L Uncertainty                    +/-630 Cobalt-56                                      U            81.9    pCi/L Uncertainty                    +/-88.7 Cobalt-57                                                    267    pCi/L Uncertainty                    +/-108 Cobalt-58                                      U          -46.9    pCi/L Uncertainty                    +/-87.5 Cobalt-60              13800                            14200    pCi/L              103 (75%-125%)
-68.5 43.7
Uncertainty                    +/-408 Europium-152                                  U          -101    pCi/L Uncertainty                    +/-237 Europium-154                                  U            43.3    pCi/L Uncertainty                    +/-136 Europium-155                                  U            146    pCi/L Uncertainty                    +/-300 Iridium-192                                    U            57.9    pCi/L Uncertainty                    +/-74.3 Iron-59                                        U            45.3    pCi/L Uncertainty                    +/-199 Lead-210                                              4.51E+05      pCi/L Uncertainty                  +/-50700 Page 42 of 49
-75.7
-268 23.7
-66.4 13700
-199 81.9 267
-46.9 14200
-101 43.3 146 57.9 45.3 4.51E+05 NOM Sample Range (75%-125%)
(75%-125%)
Qual U
U U
U U
U U
U U
U U
U U
U U
U U
REC%
102 103 13500 13800 395827 Workorder:
+/-103
+/-282
+/-768
+/-1080
+/-142
+/-66.4
+/-112
+/-478
+/-94.4
+/-158
+/-354
+/-630
+/-88.7
+/-108
+/-87.5
+/-408
+/-237
+/-136
+/-300
+/-74.3
+/-199
+/-50700 RPD%
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 5 of 12 Page 42 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:      395827                                                                                  Page 6 of 12 Parmname                    NOM        Sample Qual          QC    Units    RPD%      REC%  Range Anlst  Date Time Rad Gamma Spec Batch         1561698 Lead-212                                       U          -41.7    pCi/L Uncertainty                    +/-143 Lead-214                                        U          -66.5    pCi/L                         MJH1 04/22/16 06:39 Uncertainty                    +/-183 Manganese-54                                    U            22.0   pCi/L Uncertainty                  +/-87.1 Mercury-203                                    U          -25.5     pCi/L Uncertainty                  +/-77.1 Neodymium-147                                   U           -259    pCi/L Uncertainty                    +/-538 Neptunium-239                                  U            356    pCi/L Uncertainty                    +/-781 Niobium-94                                      U            9.74    pCi/L Uncertainty                  +/-68.8 Niobium-95                                      U            28.1    pCi/L Uncertainty                  +/-77.3 Potassium-40                                    U          -26.7    pCi/L Uncertainty                    +/-253 Promethium-144                                  U            6.91    pCi/L Uncertainty                  +/-68.5 Promethium-146                                  U          -31.7    pCi/L Uncertainty                    +/-124 Radium-228                                      U            122    pCi/L Uncertainty                    +/-399 Ruthenium-106                                  U            166    pCi/L Uncertainty                    +/-727 Silver-110m                                    U            78.2    pCi/L Uncertainty                    +/-140 Sodium-22                                      U            14.5    pCi/L Uncertainty                  +/-47.5 Thallium-208                                    U          -13.8    pCi/L Uncertainty                  +/-73.8 Thorium-234                                    U        -1950      pCi/L Uncertainty                  +/-5510 Tin-113                                        U          -66.5    pCi/L Uncertainty                    +/-108 Uranium-235                                    U            147    pCi/L Uncertainty                    +/-479 Uranium-238                                    U        -1950      pCi/L Uncertainty                  +/-5510 Yttrium-88                                      U          -3.09    pCi/L Uncertainty                  +/-28.7 Zinc-65                                                    1030    pCi/L Uncertainty                    +/-363 Page 43 of 49
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698 Batch Lead-212 Lead-214 Manganese-54 Mercury-203 Neodymium-147 Neptunium-239 Niobium-94 Niobium-95 Potassium-40 Promethium-144 Promethium-146 Radium-228 Ruthenium-106 Silver-110m Sodium-22 Thallium-208 Thorium-234 Tin-113 Uranium-235 Uranium-238 Yttrium-88 Zinc-65 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 04/22/16 06:39 QC
-41.7
-66.5 22.0
-25.5
-259 356 9.74 28.1
-26.7 6.91
-31.7 122 166 78.2 14.5
-13.8
-1950
-66.5 147
-1950
-3.09 1030 NOM Sample Range Qual U
U U
U U
U U
U U
U U
U U
U U
U U
U U
U U
REC%
395827 Workorder:
+/-143
+/-183
+/-87.1
+/-77.1
+/-538
+/-781
+/-68.8
+/-77.3
+/-253
+/-68.5
+/-124
+/-399
+/-727
+/-140
+/-47.5
+/-73.8
+/-5510
+/-108
+/-479
+/-5510
+/-28.7
+/-363 RPD%
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 6 of 12 Page 43 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:      395827                                                                                  Page 7 of 12 Parmname                    NOM        Sample Qual          QC    Units    RPD%      REC%  Range Anlst  Date Time Rad Gamma Spec Batch         1561698 Zirconium-95                                     U          31.9    pCi/L Uncertainty                    +/-141 QC1203533384    MB Actinium-228                                     U          -7.16    pCi/L                         MJH1 04/22/16 06:34 Uncertainty                    +/-8.38 Americium-241                                    U          -1.73    pCi/L Uncertainty                    +/-9.55 Antimony-124                                    U      -0.0387      pCi/L Uncertainty                    +/-2.87 Antimony-125                                    U          0.960    pCi/L Uncertainty                    +/-4.35 Barium-133                                      U          0.347    pCi/L Uncertainty                    +/-2.37 Barium-140                                      U        -0.895      pCi/L Uncertainty                    +/-6.51 Beryllium-7                                      U          -8.86    pCi/L Uncertainty                    +/-12.3 Bismuth-212                                      U          14.2    pCi/L Uncertainty                    +/-25.1 Bismuth-214                                      U          1.92    pCi/L Uncertainty                    +/-4.84 Cerium-139                                      U        -0.533      pCi/L Uncertainty                    +/-1.59 Cerium-141                                      U          2.38    pCi/L Uncertainty                    +/-2.53 Cerium-144                                      U          5.24    pCi/L Uncertainty                    +/-10.6 Cesium-134                                      U          0.137    pCi/L Uncertainty                    +/-1.84 Cesium-136                                      U          -1.24    pCi/L Uncertainty                    +/-2.06 Cesium-137                                      U          0.134    pCi/L Uncertainty                    +/-1.80 Chromium-51                                      U          1.84    pCi/L Uncertainty                    +/-13.4 Cobalt-56                                        U          0.706    pCi/L Uncertainty                    +/-1.49 Cobalt-57                                        U        -0.172      pCi/L Uncertainty                    +/-1.53 Cobalt-58                                        U          0.680    pCi/L Uncertainty                    +/-1.64 Cobalt-60                                        U          1.03    pCi/L Uncertainty                    +/-1.93 Europium-152                                    U          1.98    pCi/L Uncertainty Page 44 of 49
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698 Batch Zirconium-95 Actinium-228 Americium-241 Antimony-124 Antimony-125 Barium-133 Barium-140 Beryllium-7 Bismuth-212 Bismuth-214 Cerium-139 Cerium-141 Cerium-144 Cesium-134 Cesium-136 Cesium-137 Chromium-51 Cobalt-56 Cobalt-57 Cobalt-58 Cobalt-60 Europium-152 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 04/22/16 06:34 QC 31.9
-7.16
-1.73
-0.0387 0.960 0.347
-0.895
-8.86 14.2 1.92
-0.533 2.38 5.24 0.137
-1.24 0.134 1.84 0.706
-0.172 0.680 1.03 1.98 NOM Sample Range Qual U
U U
U U
U U
U U
U U
U U
U U
U U
U U
U U
U QC1203533384 REC%
MB 395827 Workorder:
+/-141
+/-8.38
+/-9.55
+/-2.87
+/-4.35
+/-2.37
+/-6.51
+/-12.3
+/-25.1
+/-4.84
+/-1.59
+/-2.53
+/-10.6
+/-1.84
+/-2.06
+/-1.80
+/-13.4
+/-1.49
+/-1.53
+/-1.64
+/-1.93 RPD%
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 7 of 12 Page 44 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:      395827                                                                                  Page 8 of 12 Parmname                    NOM        Sample Qual          QC    Units    RPD%      REC%  Range Anlst  Date Time Rad Gamma Spec Batch         1561698
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698 Batch Europium-154 Europium-155 Iridium-192 Iron-59 Lead-210 Lead-212 Lead-214 Manganese-54 Mercury-203 Neodymium-147 Neptunium-239 Niobium-94 Niobium-95 Potassium-40 Promethium-144 Promethium-146 Radium-228 Ruthenium-106 Silver-110m Sodium-22 Thallium-208 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 04/22/16 06:34 QC
                                                          +/-4.87 Europium-154                                    U        -0.771      pCi/L                         MJH1 04/22/16 06:34 Uncertainty                    +/-4.66 Europium-155                                    U          -2.76    pCi/L Uncertainty                    +/-6.43 Iridium-192                                    U        -0.317      pCi/L Uncertainty                    +/-1.62 Iron-59                                        U            2.12    pCi/L Uncertainty                    +/-2.97 Lead-210                                        U          -132    pCi/L Uncertainty                    +/-275 Lead-212                                        U            1.26    pCi/L Uncertainty                    +/-4.97 Lead-214                                        U            1.93    pCi/L Uncertainty                    +/-5.83 Manganese-54                                    U          -0.12    pCi/L Uncertainty                    +/-1.62 Mercury-203                                    U            1.53    pCi/L Uncertainty                    +/-1.59 Neodymium-147                                  U          -3.95    pCi/L Uncertainty                    +/-11.0 Neptunium-239                                  U        -0.573      pCi/L Uncertainty                    +/-14.9 Niobium-94                                      U        -0.765      pCi/L Uncertainty                    +/-1.67 Niobium-95                                      U      -0.0743      pCi/L Uncertainty                    +/-1.40 Potassium-40                                    U            14.3    pCi/L Uncertainty                    +/-24.8 Promethium-144                                  U          0.643    pCi/L Uncertainty                    +/-1.79 Promethium-146                                  U          0.158    pCi/L Uncertainty                    +/-2.18 Radium-228                                      U          -7.16    pCi/L Uncertainty                    +/-8.38 Ruthenium-106                                  U          -15.7    pCi/L Uncertainty                    +/-18.9 Silver-110m                                    U        -0.238      pCi/L Uncertainty                    +/-1.98 Sodium-22                                      U        -0.342      pCi/L Uncertainty                    +/-1.62 Thallium-208                                    U          -2.26    pCi/L Uncertainty                    +/-2.16 Page 45 of 49
-0.771
-2.76
-0.317 2.12
-132 1.26 1.93
-0.12 1.53
-3.95
-0.573
-0.765
-0.0743 14.3 0.643 0.158
-7.16
-15.7
-0.238
-0.342
-2.26 NOM Sample Range Qual U
U U
U U
U U
U U
U U
U U
U U
U U
U U
U U
REC%
395827 Workorder:
+/-4.87
+/-4.66
+/-6.43
+/-1.62
+/-2.97
+/-275
+/-4.97
+/-5.83
+/-1.62
+/-1.59
+/-11.0
+/-14.9
+/-1.67
+/-1.40
+/-24.8
+/-1.79
+/-2.18
+/-8.38
+/-18.9
+/-1.98
+/-1.62
+/-2.16 RPD%
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 8 of 12 Page 45 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:      395827                                                                                                Page 9 of 12 Parmname                              NOM        Sample Qual          QC    Units    RPD%      REC%    Range  Anlst  Date Time Rad Gamma Spec Batch         1561698 Thorium-234                                               U          60.3    pCi/L Uncertainty                    +/-140 Tin-113                                                  U          0.153    pCi/L                             MJH1 04/22/16 06:34 Uncertainty                  +/-2.10 Uranium-235                                              U        -0.388      pCi/L Uncertainty                  +/-13.5 Uranium-238                                              U          60.3    pCi/L Uncertainty                    +/-140 Yttrium-88                                                U        -0.798      pCi/L Uncertainty                  +/-1.85 Zinc-65                                                  U          0.806    pCi/L Uncertainty                  +/-3.61 Zirconium-95                                              U          -1.7    pCi/L Uncertainty                  +/-2.56 Batch        1562602 QC1203535844  395827001 DUP Iodine-129                                    U  -0.0373  U          0.388    pCi/L     N/A                  N/A MJH1 04/27/16 09:20 Uncertainty  +/-0.859        +/-1.13 QC1203535846    LCS Iodine-129                          52.0                              50.2    pCi/L            96.4 (75%-125%)      04/27/16 11:04 Uncertainty                  +/-6.44 QC1203535843    MB Iodine-129                                                U        -0.17      pCi/L                                  04/27/16 09:19 Uncertainty                  +/-0.835 QC1203535845  395827001 MS Iodine-129                          52.0     U  -0.0373             57.5     pCi/L              111 (75%-125%)       04/27/16 09:20 Uncertainty  +/-0.859        +/-6.83 Batch        1562693 QC1203536150   395827001 DUP Nickel-59                                    U      5.85 U          3.14    pCi/L    N/A                 N/A CXS7 04/28/16 15:36 Uncertainty  +/-6.40        +/-2.49 QC1203536151    LCS Nickel-59                            419                              372    pCi/L            88.8 (75%-125%)      04/29/16 06:45 Uncertainty                  +/-26.7 QC1203536149    MB Nickel-59                                                U          2.87    pCi/L                                  04/28/16 15:36 Uncertainty                  +/-5.02 Rad Gas Flow Batch        1562716 QC1203536198  395827001 DUP Strontium-89                                  U      1.08 U        -1.39      pCi/L    N/A                  N/A KSD1 05/02/16 16:24 Uncertainty  +/-1.29        +/-1.93 Strontium-90                                  U    0.331 U        -0.222      pCi/L    N/A                  N/A Uncertainty  +/-0.980        +/-1.22 QC1203536199    LCS Strontium-89                        522                              550    pCi/L              105 (75%-125%)      05/02/16 16:24 Page 46 of 49
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Rad Gas Flow 1561698 1562602 1562693 1562716 Batch Batch Batch Batch Thorium-234 Tin-113 Uranium-235 Uranium-238 Yttrium-88 Zinc-65 Zirconium-95 Iodine-129 Iodine-129 Iodine-129 Iodine-129 Nickel-59 Nickel-59 Nickel-59 Strontium-89 Strontium-90 Strontium-89 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 MJH1 CXS7 KSD1 04/22/16 06:34 04/27/16 09:20 04/27/16 11:04 04/27/16 09:19 04/27/16 09:20 04/28/16 15:36 04/29/16 06:45 04/28/16 15:36 05/02/16 16:24 05/02/16 16:24 QC 60.3 0.153
-0.388 60.3
-0.798 0.806
-1.7 0.388 50.2
-0.17 57.5 3.14 372 2.87
-1.39
-0.222 550 NOM Sample
-0.0373
-0.0373 5.85 1.08 0.331 Range N/A (75%-125%)
(75%-125%)
N/A (75%-125%)
N/A N/A (75%-125%)
Qual U
U U
U U
U U
U U
U U
U U
QC1203535844 395827001 QC1203535846 QC1203535843 QC1203535845 395827001 QC1203536150 395827001 QC1203536151 QC1203536149 QC1203536198 395827001 QC1203536199 N/A N/A N/A N/A REC%
96.4 111 88.8 105 52.0 52.0 419 522 DUP LCS MB MS DUP LCS MB DUP LCS 395827 Workorder:
U U
U U
U
+/-0.859
+/-0.859
+/-6.40
+/-1.29
+/-0.980
+/-140
+/-2.10
+/-13.5
+/-140
+/-1.85
+/-3.61
+/-2.56
+/-1.13
+/-6.44
+/-0.835
+/-6.83
+/-2.49
+/-26.7
+/-5.02
+/-1.93
+/-1.22 RPD%
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 9 of 12 Page 46 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:        395827                                                                                                Page 10 of 12 Parmname                                NOM          Sample Qual        QC    Units    RPD%      REC%    Range  Anlst  Date Time Rad Gas Flow Batch           1562716 Uncertainty
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gas Flow Rad Liquid Scintillation 1562716 1562672 1562678 1562683 1562687 Batch Batch Batch Batch Batch Strontium-90 Strontium-89 Strontium-90 Iron-55 Iron-55 Iron-55 Nickel-63 Nickel-63 Nickel-63 Technetium-99 Technetium-99 Technetium-99 Tritium Tritium Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time KSD1 CXS7 CXS7 MYM1 GXR1 05/02/16 16:24 05/02/16 16:27 04/28/16 23:26 04/29/16 00:13 04/28/16 22:39 04/29/16 14:53 04/29/16 15:09 04/29/16 14:37 05/03/16 15:12 05/03/16 15:28 05/03/16 14:55 04/29/16 23:11 04/30/16 11:54 QC 445
                                                                        +/-13.0 Strontium-90                           536                                445    pCi/L               83 (75%-125%) KSD1 05/02/16 16:24 Uncertainty                    +/-10.4 QC1203536197        MB Strontium-89                                                  U          -1.5    pCi/L                                  05/02/16 16:27 Uncertainty                    +/-1.18 Strontium-90                                                  U        0.116    pCi/L Uncertainty                    +/-1.00 Rad Liquid Scintillation Batch          1562672 QC1203536077      395827001 DUP Iron-55                                                  95.3            91.2    pCi/L    4.42        (0% - 100%) CXS7 04/28/16 23:26 Uncertainty    +/-60.5        +/-58.8 QC1203536078        LCS Iron-55                                1660                              1440    pCi/L            86.8 (75%-125%)      04/29/16 00:13 Uncertainty                    +/-86.2 QC1203536076        MB Iron-55                                                      U        -42.5    pCi/L                                  04/28/16 22:39 Uncertainty                    +/-58.1 Batch          1562678 QC1203536093      395827001 DUP Nickel-63                                                794              840    pCi/L    5.65          (0%-20%) CXS7 04/29/16 14:53 Uncertainty    +/-71.2        +/-71.1 QC1203536094        LCS Nickel-63                              1690                              2090    pCi/L              124 (75%-125%)      04/29/16 15:09 Uncertainty                    +/-101 QC1203536092        MB Nickel-63                                                    U        -6.46    pCi/L                                  04/29/16 14:37 Uncertainty                    +/-37.6 Batch          1562683 QC1203536112      395827001 DUP Technetium-99                                            3890             254    pCi/L      175 *        (0%-20%) MYM1 05/03/16 15:12 Uncertainty    +/-93.7        +/-33.3 QC1203536113        LCS Technetium-99                          861                                841    pCi/L            97.7 (75%-125%)       05/03/16 15:28 Uncertainty                    +/-48.9 QC1203536111        MB Technetium-99                                                U        -11.4    pCi/L                                  05/03/16 14:55 Uncertainty                    +/-24.1 Batch          1562687 QC1203536127      395827001 DUP Tritium                                            1.70E+06        1.72E+06      pCi/L    1.36          (0%-20%) GXR1 04/29/16 23:11 Uncertainty  +/-33300        +/-33700 QC1203536129        LCS Tritium                                2350                              2410    pCi/L              102 (75%-125%)      04/30/16 11:54 Uncertainty                    +/-461 Page 47 of 49
-1.5 0.116 91.2 1440
-42.5 840 2090
-6.46 254 841
-11.4 1.72E+06 2410 NOM Sample 95.3 794 3890 1.70E+06 Range (75%-125%)
(0% - 100%)
(75%-125%)
(0%-20%)
(75%-125%)
(0%-20%)
(75%-125%)
(0%-20%)
(75%-125%)
Qual U
U U
U U
QC1203536197 QC1203536077 395827001 QC1203536078 QC1203536076 QC1203536093 395827001 QC1203536094 QC1203536092 QC1203536112 395827001 QC1203536113 QC1203536111 QC1203536127 395827001 QC1203536129 4.42 5.65 175 1.36 REC%
83 86.8 124 97.7 102 536 1660 1690 861 2350 MB DUP LCS MB DUP LCS MB DUP LCS MB DUP LCS 395827 Workorder:
+/-60.5
+/-71.2
+/-93.7
+/-33300
+/-13.0
+/-10.4
+/-1.18
+/-1.00
+/-58.8
+/-86.2
+/-58.1
+/-71.1
+/-101
+/-37.6
+/-33.3
+/-48.9
+/-24.1
+/-33700
+/-461 RPD%
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 10 of 12 Page 47 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:        395827                                                                                                            Page 11 of 12 Parmname                                        NOM          Sample Qual            QC      Units    RPD%  REC%    Range  Anlst  Date Time Rad Liquid Scintillation Batch           1562687 QC1203536126        MB Tritium                                                                 U            136      pCi/L                         GXR1 04/29/16 22:55 Uncertainty                          +/-301 QC1203536128      395827001 MS Tritium                                      4710          1.70E+06           1.62E+06         pCi/L          N/A (75%-125%)       04/29/16 23:13 Uncertainty  +/-33300            +/-31600 Batch          1562691 QC1203536142     395827001 DUP Carbon-14                                              U        14.9 U              28.0      pCi/L    N/A             N/A TXJ1 05/03/16 17:23 Uncertainty    +/-24.1             +/-24.9 QC1203536144        LCS Carbon-14                                    1260                                  1310        pCi/L          103 (75%-125%)      05/03/16 18:26 Uncertainty                        +/-47.0 QC1203536141        MB Carbon-14                                                                U          -4.59        pCi/L                              05/03/16 16:51 Uncertainty                        +/-23.6 QC1203536143      395827001 MS Carbon-14                                    1260      U        14.9                1400        pCi/L          111 (75%-125%)      05/03/16 17:54 Uncertainty    +/-24.1            +/-49.8 Notes:
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Liquid Scintillation 1562687 1562691 Batch Batch Tritium Tritium Carbon-14 Carbon-14 Carbon-14 Carbon-14 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time GXR1 TXJ1 04/29/16 22:55 04/29/16 23:13 05/03/16 17:23 05/03/16 18:26 05/03/16 16:51 05/03/16 17:54 QC 136 1.62E+06 28.0 1310
-4.59 1400 NOM Sample 1.70E+06 14.9 14.9 Range (75%-125%)
N/A (75%-125%)
(75%-125%)
Qual U
U U
QC1203536126 QC1203536128 395827001 QC1203536142 395827001 QC1203536144 QC1203536141 QC1203536143 395827001 The Qualifiers in this report are defined as follows:
N/A REC%
N/A 103 111 4710 1260 1260 MB MS DUP LCS MB MS 395827 Workorder:
BD FA H
J K
L M
M N/A N1 ND NJ Q
R U
Analyte is a Tracer compound Result is less than value reported Result is greater than value reported Results are either below the MDC or tracer recovery is low Failed analysis.
Analytical holding time was exceeded Value is estimated Analyte present. Reported value may be biased high. Actual value is expected to be lower.
Analyte present. Reported value may be biased low. Actual value is expected to be higher.
M if above MDC and less than LLD REMP Result > MDC/CL and < RDL RPD or %Recovery limits do not apply.
See case narrative Analyte concentration is not detected above the detection limit Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier One or more quality control criteria have not been met. Refer to the applicable narrative or DER.
Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.
U U
+/-33300
+/-24.1
+/-24.1
+/-301
+/-31600
+/-24.9
+/-47.0
+/-23.6
+/-49.8 RPD%
Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Notes:
Counting Uncertainty is calculated at the 95% confidence level (1.96-sigma).
Counting Uncertainty is calculated at the 95% confidence level (1.96-sigma).
The Qualifiers in this report are defined as follows:
Page 11 of 12 Page 48 of 49
      **  Analyte is a Tracer compound
      <    Result is less than value reported
      >    Result is greater than value reported BD  Results are either below the MDC or tracer recovery is low FA  Failed analysis.
H    Analytical holding time was exceeded J    Value is estimated K    Analyte present. Reported value may be biased high. Actual value is expected to be lower.
L    Analyte present. Reported value may be biased low. Actual value is expected to be higher.
M    M if above MDC and less than LLD M    REMP Result > MDC/CL and < RDL N/A RPD or %Recovery limits do not apply.
N1  See case narrative ND  Analyte concentration is not detected above the detection limit NJ  Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Q    One or more quality control criteria have not been met. Refer to the applicable narrative or DER.
R    Sample results are rejected U    Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.
Page 48 of 49


GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:        395827                                                                                                                                Page 12 of 12 Parmname                                      NOM             Sample Qual           QC      Units      RPD%        REC%         Range    Anlst        Date Time UI   Gamma Spectroscopy--Uncertain identification UJ    Gamma Spectroscopy--Uncertain identification UL    Not considered detected. The associated number is the reported concentration, which may be inaccurate due to a low bias.
QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Parmname Page 12 of 12 Units Anlst Date Time QC NOM Sample Range Qual REC%
X    Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y    Other specific qualifiers were required to properly define the results. Consult case narrative.
395827 Workorder:
      ^    RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.
UI UJ UL X
h    Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more or %RPD not applicable.
Y
  ^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptance criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.
^
h Gamma Spectroscopy--Uncertain identification Gamma Spectroscopy--Uncertain identification Not considered detected. The associated number is the reported concentration, which may be inaccurate due to a low bias.
Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Other specific qualifiers were required to properly define the results. Consult case narrative.
RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.
Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more or %RPD not applicable.
^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptance criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.
* Indicates that a Quality Control parameter was not within specifications.
* Indicates that a Quality Control parameter was not within specifications.
For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.
For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.
RPD%
Page 49 of 49}}
Page 49 of 49}}

Latest revision as of 20:52, 9 January 2025

Response to NRC Questions Related to Request for 20.2002 Disposal of Contaminated Water
ML16231A028
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 08/11/2016
From: Silko T
Entergy Corp
To: Jack Parrott
Reactor Decommissioning Branch
PARROTJ , 415-6634, T-8E47
References
SDG: 395827
Download: ML16231A028 (52)


Text

From: Silko, Thomas B. [1]

Sent: Thursday, August 11, 2016 11:26 AM To: Parrott, Jack <Jack.Parrott@nrc.gov>

Subject:

[External_Sender] Response to NRC Questions dated 7-28-16

Jack, Based upon our conversation on Wednesday 8/3/16, VY agreed to provide a copy of the Part 61 analysis which was used to identify the radionuclide concentrations on the Torus water. Accordingly, please find attached a copy of the Part 61 report from GEL Laboratories, dated April 26, 2016.

In response to the Staffs second question, VY and the NRC discussed the process for sampling of material prior to making radioactive shipments. VY procedure V-EN-RW-102, Shipment of Radioactive Material, requires an isotopic be performed to ensure the material is appropriately classified per 10 CFR 61.55 requirements. The isotopic is performed on a sample of the material (in this case a water sample) prior to completing the shipment manifest. As such, VY is committed to sampling water prior to shipment to satisfy the requirements of 10CFR61.55.

In addition, Vermont Yankee commits to the following: Vermont Yankee will perform a representative sample prior to each shipment of water and will confirm that the radionuclide concentrations result in doses that are equal to or less than, the doses delineated within the Summary of Project Alternative Disposal Dose Results, in our June 28, 2016 letter (BVY 16-021; ADAMS Accession No. ML16182A035).

For example, the above could be satisfied in the following manner: A representative sample is taken prior to a shipment and the radionuclide concentrations are verified to be equal to or less than those concentrations shown on the Data Input Worksheet, of our June 28, 2016 letter. An alternative method to be used, such as when a radionuclide is identified as being slightly above the concentrations (while others may be lower), then sample radionuclide concentrations would be input into the Site Specific Dose Assessment Methodology (SSDA) used in our June 28, 2016 letter and the dose consequences verified to be equal to or less than that delineated within the Summary of Project Alternative Disposal Dose Results.

Please let me know if there are any further questions.

Thank You.

Tom Silko (802) 451-3166

April 26, 2016 Mr. Mark Vandale Entergy Nuclear Operations, Inc., VY 530 Governor Hunt Road PO Box 250 Vernon, Vermont 05354 Re: Vermont Yankee Part 61 Work Order: 395827

Dear Mr. Vandale:

GEL Laboratories, LLC (GEL) appreciates the opportunity to provide the enclosed analytical results for the sample(s) we received on April 21, 2016. This original data report has been prepared and reviewed in accordance with GELs standard operating procedures.

Our policy is to provide high quality, personalized analytical services to enable you to meet your analytical needs on time every time. We trust that you will find everything in order and to your satisfaction. If you have any questions, please do not hesitate to call me at (843) 556-8171, ext. 4504.

Sincerely, PM_SIGN_HERE Erin Trent Project Manager Purchase Order: 10287833 Enclosures

Table of Contents Case Narrative......................................................................................1 Chain of Custody..................................................................................3 Laboratory Certifications......................................................................7 Radiological Analysis...........................................................................9 Case Narrative............................................................................10 Sample Data Summary...............................................................33 Quality Control Summary..........................................................37

Case Narrative Page 1 of 49

Case Narrative for Vermont Yankee, Entergy Nuclear Operations Inc.

SDG: 395827 April 26, 2016 Laboratory Identification:

GEL Laboratories LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample Receipt The sample arrived at GEL Laboratories LLC, Charleston, South Carolina on April 21, 2016 for analysis. Chain of Custody form did not contain a relinquished signature. All sample containers arrived without any visible signs of tampering or breakage. There are no additional comments concerning sample receipt.

Sample Identification The laboratory received the following sample:

Laboratory ID Client ID 395827001 Torus Water #2 Case Narrative Sample analyses were conducted using methodology as outlined in GEL Laboratories, LLC (GEL)

Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, and data from the following fractions: Radiochemistry.

PM_SIGN_HERE Erin Trent Project Manager Page 2 of 49

Chain of Custody Page 3 of 49

Page 4 of 49

Page 5 of 49

Page 6 of 49

Laboratory Certifications Page 7 of 49

State Certification Alaska Arkansas CLIA California Colorado Connecticut Delaware DoD ELAP/ ISO17025 A2LA Florida NELAP Foreign Soils Permit Georgia Georgia SDWA Hawaii Idaho Chemistry Idaho Radiochemistry Illinois NELAP Indiana Kansas NELAP Kentucky SDWA Kentucky Wastewater Louisiana NELAP Louisiana SDWA Maryland Massachusetts Michigan Mississippi Nebraska Nevada New Hampshire NELAP New Jersey NELAP New Mexico New York NELAP North Carolina North Carolina SDWA North Dakota Oklahoma Pennsylvania NELAP S.Carolina Radchem South Carolina Chemistry Tennessee Texas NELAP Utah NELAP Vermont Virginia NELAP Washington West Virginia UST0110 880651 42D0904046 2940 SC00012 PH0169 SC00012 2567.01 E87156 P3301500283, P3301500253 SC00012 967 SC00012 SC00012 SC00012 200029 CSC01 E10332 90129 90129 03046 (AI33904)

LA160006 270 MSC012 9976 SC00012 NEOS2613 SC0001220161 205415 SC002 SC00012 11501 233 45709 R158 9904 6800485 10120002 10120001 TN 02934 T1047042351611 SC00012201620 VT87156 460202 C780 997404 List of current GEL Certifications as of 26 April 2016 Page 8 of 49

Radiological Analysis Page 9 of 49

Case Narrative Page 10 of 49

Radiochemistry Technical Case Narrative Vermont Yankee, Entergy Nuclear Operations Inc. (NTRG)

SDG #: 395827 Method/Analysis Information Product:

Alphaspec Pu242, Liquid Analytical Method:

DOE EML HASL-300, Pu-11-RC Modified Analytical Batch Number:

1562629 Sample ID Client ID 395827001 Torus Water #2 1203535939 Method Blank (MB) 1203535941 Laboratory Control Sample (LCS) 1203535940 395827001(Torus Water #2) Sample Duplicate (DUP)

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 26.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

QC Information All of the QC samples met the required acceptance limits.

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Page 11 of 49

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Recounts Sample 395827001 (Torus Water #2) was recounted due to a suspected false positive. The recount is reported.

Miscellaneous Information:

Data Exception (DER) Documentation Data exception reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A data exception report (DER) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments Additional comments were not required for this sample set.

Qualifier Information Manual qualifiers were not required.

Method/Analysis Information Product:

Alphaspec Am241, Cm, Liquid Analytical Method:

DOE EML HASL-300, Am-05-RC Modified Analytical Batch Number:

1562630 Sample ID Client ID 395827001 Torus Water #2 1203535946 Method Blank (MB) 1203535948 Laboratory Control Sample (LCS) 1203535947 395827001(Torus Water #2) Sample Duplicate (DUP)

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with Page 12 of 49

GL-RAD-A-011 REV# 26.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

QC Information All of the QC samples met the required acceptance limits.

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Recounts None of the samples in this sample set were recounted.

Miscellaneous Information:

Data Exception (DER) Documentation Data exception reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A data exception report (DER) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments Additional comments were not required for this sample set.

Qualifier Information Manual qualifiers were not required.

Page 13 of 49

Method/Analysis Information Product:

Alphaspec Np, Liquid Analytical Method:

ASTM C 1476-00 Modified Analytical Batch Number:

1562631 Sample ID Client ID 395827001 Torus Water #2 1203535949 Method Blank (MB) 1203535951 Laboratory Control Sample (LCS) 1203535950 395827001(Torus Water #2) Sample Duplicate (DUP)

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-032 REV# 20.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

QC Information All of the QC samples met the required acceptance limits.

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Sample Re-prep/Re-analysis Page 14 of 49

None of the samples in this sample set required reprep or reanalysis.

Recounts None of the samples in this sample set were recounted.

Miscellaneous Information:

Data Exception (DER) Documentation Data exception reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A data exception report (DER) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments Additional comments were not required for this sample set.

Qualifier Information Manual qualifiers were not required.

Method/Analysis Information Product:

Gammaspec, Gamma, Liquid (Standard List)

Analytical Method:

EPA 901.1 Analytical Batch Number:

1561698 Sample ID Client ID 395827001 Torus Water #2 1203533384 Method Blank (MB) 1203533386 Laboratory Control Sample (LCS) 1203533385 395827001(Torus Water #2) Sample Duplicate (DUP)

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 25.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Page 15 of 49

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

QC Information All of the QC samples meet the required acceptance limits with the following exceptions: Refer to Data Exception Report (DER).

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Recounts None of the samples in this sample set were recounted.

Miscellaneous Information:

Data Exception (DER) Documentation Data exception reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. The following DER was generated for this SDG: DER 1513408 was generated due to RDL less than MDA. The following RDLs in sample 395827001 were not achieved: Cs-134, Fe-59, Nb-95 and Zr-95. The following RDLs in DUP 1203533385 were not achieved: Cs-134, Fe-59, Nb-95 and Zr-95. Samples did not meet the required detection limit due to high sample activity. Reporting results.

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments Additional comments were not required for this sample set.

Qualifier Information Manual qualifiers were not required.

Method/Analysis Information Page 16 of 49

Product:

Gamma I129, Liquid Analytical Method:

DOE EML HASL-300,I-01 Modified Analytical Batch Number:

1562602 Sample ID Client ID 395827001 Torus Water #2 1203535843 Method Blank (MB) 1203535846 Laboratory Control Sample (LCS) 1203535844 395827001(Torus Water #2) Sample Duplicate (DUP) 1203535845 395827001(Torus Water #2) Matrix Spike (MS)

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-006 REV# 21.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

QC Information All of the QC samples met the required acceptance limits.

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Recounts None of the samples in this sample set were recounted.

Page 17 of 49

Miscellaneous Information:

Data Exception (DER) Documentation Data exception reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A data exception report (DER) was not generated for this SDG.

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments Additional comments were not required for this sample set.

Qualifier Information Manual qualifiers were not required.

Method/Analysis Information Product:

Gamma Ni59, Liquid Analytical Method:

DOE RESL Ni-1 Analytical Batch Number:

1562693 Sample ID Client ID 395827001 Torus Water #2 1203536149 Method Blank (MB) 1203536151 Laboratory Control Sample (LCS) 1203536150 395827001(Torus Water #2) Sample Duplicate (DUP)

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 17.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Page 18 of 49

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

QC Information All of the QC samples met the required acceptance limits.

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Recounts None of the samples in this sample set were recounted.

Miscellaneous Information:

Data Exception (DER) Documentation Data exception reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A data exception report (DER) was not generated for this SDG.

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments Additional comments were not required for this sample set.

Qualifier Information Manual qualifiers were not required.

Method/Analysis Information Product:

GFPC, Sr89&Sr90, Liquid Analytical Method:

EPA 905.0 Modified/DOE RP501 Rev. 1 Modified Analytical Batch Number:

1562716 Sample ID Client ID Page 19 of 49

395827001 Torus Water #2 1203536197 Method Blank (MB) 1203536199 Laboratory Control Sample (LCS) 1203536198 395827001(Torus Water #2) Sample Duplicate (DUP)

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 17.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

QC Information All of the QC samples met the required acceptance limits.

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Recounts Sample 1203536198 (Torus Water #2DUP) was recounted due to a suspected total strontium false positive. The recount is reported.

Miscellaneous Information:

Data Exception (DER) Documentation Data exception reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A data exception report (DER) was not generated for this SDG.

Page 20 of 49

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments Additional comments were not required for this sample set.

Qualifier Information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Pu241, Liquid Analytical Method:

DOE EML HASL-300, Pu-11-RC Modified Analytical Batch Number:

1562632 Sample ID Client ID 395827001 Torus Water #2 1203535952 Method Blank (MB) 1203535954 Laboratory Control Sample (LCS) 1203535953 395827001(Torus Water #2) Sample Duplicate (DUP)

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 16.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Page 21 of 49

QC Information All of the QC samples met the required acceptance limits.

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Recounts Samples 1203535952 (MB), 1203535953 (Torus Water #2DUP) and 395827001 (Torus Water #2) were recounted due to high MDCs. The recounts are reported.

Miscellaneous Information:

Data Exception (DER) Documentation Data exception reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A data exception report (DER) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments Additional comments were not required for this sample set.

Qualifier Information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Fe55, Liquid Analytical Method:

DOE RESL Fe-1, Modified Analytical Batch Number:

1562672 Sample ID Client ID 395827001 Torus Water #2 1203536076 Method Blank (MB) 1203536078 Laboratory Control Sample (LCS) 1203536077 395827001(Torus Water #2) Sample Duplicate (DUP)

Page 22 of 49

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

QC Information All of the QC samples met the required acceptance limits.

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Recounts None of the samples in this sample set were recounted.

Miscellaneous Information:

Data Exception (DER) Documentation Data exception reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A data exception report (DER) was not generated for this SDG.

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments Additional comments were not required for this sample set.

Page 23 of 49

Qualifier Information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Ni63, Liquid Analytical Method:

DOE RESL Ni-1, Modified Analytical Batch Number:

1562678 Sample ID Client ID 395827001 Torus Water #2 1203536092 Method Blank (MB) 1203536094 Laboratory Control Sample (LCS) 1203536093 395827001(Torus Water #2) Sample Duplicate (DUP)

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 17.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

QC Information All of the QC samples met the required acceptance limits.

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Page 24 of 49

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Recounts None of the samples in this sample set were recounted.

Miscellaneous Information:

Data Exception (DER) Documentation Data exception reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A data exception report (DER) was not generated for this SDG.

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments Additional comments were not required for this sample set.

Qualifier Information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Tc99, Liquid Analytical Method:

DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number:

1562683 Sample ID Client ID 395827001 Torus Water #2 1203536111 Method Blank (MB) 1203536113 Laboratory Control Sample (LCS) 1203536112 395827001(Torus Water #2) Sample Duplicate (DUP)

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-059 REV# 4.

Page 25 of 49

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

QC Information All of the QC samples meet the required acceptance limits with the following exceptions: Refer to Data Exception Report (DER).

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Recounts Samples were recounted due to high relative percent difference/relative error ratio. The recount results are similar to the original results. Original results are reported.

Miscellaneous Information:

Data Exception (DER) Documentation A data exception report (DER) 1517546 was generated for samples in this SDG/batch. DER 1517546 was generated due to Failed RPD for DUP. 1. Sample 395827001 and duplicate 1203536112 do not meet the relative percent difference requirement or the relative error ratio requirement due to the matrix of the sample. 1.

Reporting results.

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments Additional comments were not required for this sample set.

Qualifier Information Manual qualifiers were not required.

Page 26 of 49

Method/Analysis Information Product:

LSC, Tritium Dist, Liquid Analytical Method:

EPA 906.0 Modified Analytical Batch Number:

1562687 Sample ID Client ID 395827001 Torus Water #2 1203536126 Method Blank (MB) 1203536129 Laboratory Control Sample (LCS) 1203536127 395827001(Torus Water #2) Sample Duplicate (DUP) 1203536128 395827001(Torus Water #2) Matrix Spike (MS)

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 21.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

QC Information All of the QC samples meet the required acceptance limits with the following exceptions: The Matrix Spike 1203536128 (Torus Water #2MS) did not meet recovery requirements due to the sample activity being greater than five times the spiked nominal concentration.

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Page 27 of 49

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Recounts Sample 1203536129 (LCS) was recounted due to low recovery. The recount is reported.

Miscellaneous Information:

Data Exception (DER) Documentation Data exception reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A data exception report (DER) was not generated for this SDG.

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments The matrix spike, 1203536128 (Torus Water #2MS), aliquot was reduced to conserve sample volume.

Qualifier Information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint C14, Liquid Analytical Method:

EPA EERF C-01 Modified Analytical Batch Number:

1562691 Sample ID Client ID 395827001 Torus Water #2 1203536141 Method Blank (MB) 1203536144 Laboratory Control Sample (LCS) 1203536142 395827001(Torus Water #2) Sample Duplicate (DUP) 1203536143 395827001(Torus Water #2) Matrix Spike (MS)

The samples in this SDG were analyzed on an "as received" basis.

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by GEL Laboratories LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 15.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Page 28 of 49

Standards Information Standard solutions for these analysis are NIST traceable or verified with a NIST traceable standard and used before the expiration dates.

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

QC Information All of the QC samples met the required acceptance limits.

Designated QC The following sample was used for QC: 395827001 (Torus Water #2).

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Recounts None of the samples in this sample set were recounted.

Miscellaneous Information:

Data Exception (DER) Documentation Data exception reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A data exception report (DER) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Sample-Specific MDA/MDC The MDA/MDC reported on the certificate of analysis is a sample-specific MDA/MDC.

Additional Comments Additional comments were not required for this sample set.

Qualifier Information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Page 29 of 49

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com VERM001 Vermont Yankee, Entergy Nuclear Operations Inc.

Client SDG: 395827 GEL Work Order: 395827 Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with GEL Laboratories LLC standard operating procedures. Please direct any questions to your Project Manager, Erin Trent.

Reviewed by Sample(s) Contained within this report:

395827001 Lab Sample ID Client Sample ID Sample Description Torus Water #2 N/A Collected 04/11/2016 09:10 Signature:

Name:

Date:

Title:

05 MAY 2016 Theresa Austin Group Leader Page 30 of 49

1513408 DER Report No.:

1 Revision No.:

Spencer Collins Originator's Name:

22-APR-16 Shenise Gerideau Data Validator/Group Leader:

22-APR-16 Instrument Type:

Client Code:

Quality Criteria:

GAMMA SPECTROMETER Specifications VERM Type:

Process Division:

Radiochemistry Mo.Day Yr.

22-APR-16 GEL Laboratories LLC Form GEL-DER DATA EXCEPTION REPORT DER Disposition:

Samples did not meet the required detection limit due to high sample activity. Reporting results.

Specification and Requirements Exception

Description:

The following RDLs in sample 395827001 were not achieved: Cs-134, Fe-59, Nb-95 and Zr-95.

The following RDLs in DUP 1203533385 were not achieved: Cs-134, Fe-59, Nb-95 and Zr-95.

Application Issues:

RDL less than MDA Batch ID:

1561698 Test / Method:

EPA 901.1 Liquid Matrix Type:

See Below Sample Numbers:

Potentially affected work order(s)(SDG):395827 Page 31 of 49

1517546 DER Report No.:

2 Revision No.:

Elizabeth Krouse Originator's Name:

05-MAY-16 Lyndsey Pace Data Validator/Group Leader:

05-MAY-16 Instrument Type:

Client Code:

Quality Criteria:

LSC Specifications VERM Type:

Process Division:

Radiochemistry Mo.Day Yr.

05-MAY-16 GEL Laboratories LLC Form GEL-DER DATA EXCEPTION REPORT DER Disposition:

1. Reporting results.

Specification and Requirements Exception

Description:

1. Sample 395827001 and duplicate 1203536112 do not meet the relative percent difference requirement or the relative error ratio requirement due to the matrix of the sample.

Application Issues:

Failed RPD for DUP Batch ID:

1562683 Test / Method:

DOE EML HASL-300, Tc-02-RC Modified Liquid Matrix Type:

See Below Sample Numbers:

Potentially affected work order(s)(SDG):395827 Page 32 of 49

Sample Data Summary Page 33 of 49

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Note(s): 1. Calculated MDAs are a-posteriori values at the 95% confidence level.

2. Activity is reported on a dry weight basis unless otherwise indicated in the case narrativeand is decay corrected to the sample collect date.
3. Results are statistically positive at the 95% confidence level. (activity is greater than or equal to the two sigma uncertainty)

U Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.

10 CFR Part 50/61 Certificate of Analysis GEL Sample ID:

Matrix:

Geometry Received:

Client:

Collect Date:

Receive Date:

Client Sample ID:

395827001 Water Vermont Yankee, Entergy Nuclear Operatio April 11, 2016 April 21, 2016 Torus Water #2 Report Date: May 05, 2016 Analyte Run Date Activity MDA Qualifier 2 Sigma Uncertainty RL Alpha Spec Gamma Spec H-3 C-14 Fe-55 Ni-63 Sr-89 Sr-90 Tc-99 Pu-241 Np-237 Pu-238 Pu-239/240 Pu-242 Am-241 Cm-242 Cm-243/244 Be-7 Na-22 K-40 Cr-51 Mn-54 Fe-59 Co-56 Co-57 Co-58 Co-60 Ni-59 Zn-65 Y-88 Zr-95 Nb-94 Nb-95 Ru-106 Ag-110m Sn-113 04/29/16 05/03/16 04/28/16 04/29/16 05/02/16 05/02/16 05/03/16 05/04/16 04/30/16 05/02/16 05/02/16 05/02/16 04/30/16 04/30/16 04/30/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/28/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 1.70E+06 1.49E+01 9.53E+01 7.94E+02 1.08E+00 3.31E-01 3.89E+03 7.38E+00

-1.66E-01 1.96E-02 4.85E-02 1.91E-01 4.31E-02 0.00E+00

-5.11E-03 3.92E+01 6.07E+00 1.14E+01 3.07E+01 4.71E+02 2.87E+01 7.28E+00 3.24E+00 9.00E+01 2.07E+04 5.85E+00 1.95E+03

-1.32E+00 2.37E+01

-7.62E+00 6.97E+00 3.19E+01

-4.46E+00 9.02E+00 3.33E+04 2.41E+01 6.05E+01 7.12E+01 1.29E+00 9.80E-01 9.37E+01 1.13E+01 3.14E-01 2.14E-01 2.13E-01 2.99E-01 7.39E-02 4.66E-02 4.41E-02 9.40E+01 7.93E+00 5.16E+01 9.82E+01 2.43E+01 3.55E+01 1.52E+01 7.66E+00 2.06E+01 7.10E+01 6.40E+00 6.85E+01 5.08E+00 2.40E+01 1.13E+01 1.34E+01 1.04E+02 2.14E+01 1.28E+01 1.75E+03 4.08E+01 8.07E+01 7.04E+01 2.18E+00 2.66E+00 4.26E+01 1.91E+01 9.68E-01 4.50E-01 3.86E-01 4.10E-01 6.47E-02 6.93E-02 1.02E-01 1.59E+02 1.35E+01 8.56E+01 1.69E+02 2.38E+01 6.01E+01 2.61E+01 1.28E+01 2.46E+01 1.26E+01 1.01E+01 5.59E+01 8.67E+00 4.17E+01 1.84E+01 2.31E+01 1.72E+02 3.65E+01 2.19E+01 2.00E+03 5.00E+01 1.10E+02 5.30E+02 2.30E+01 3.50E+00 5.00E+01 2.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 1.50E+01 3.00E+01 1.50E+01 1.50E+01 2.00E+01 3.00E+01 3.00E+01 1.50E+01 3

U 3

3 U

U 3

U U

U U

U U

U U

U U

U U

3 U

U U

3 3

U 3

U U

U U

U U

U 1

2 pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Units Page 34 of 49

GEL LABORATORIES LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Note(s): 1. Calculated MDAs are a-posteriori values at the 95% confidence level.

2. Activity is reported on a dry weight basis unless otherwise indicated in the case narrativeand is decay corrected to the sample collect date.
3. Results are statistically positive at the 95% confidence level. (activity is greater than or equal to the two sigma uncertainty)

U Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.

10 CFR Part 50/61 Certificate of Analysis GEL Sample ID:

Matrix:

Geometry Received:

Client:

Collect Date:

Receive Date:

Client Sample ID:

395827001 Water Vermont Yankee, Entergy Nuclear Operatio April 11, 2016 April 21, 2016 Torus Water #2 Report Date: May 05, 2016 Analyte Run Date Activity MDA Qualifier 2 Sigma Uncertainty RL Sb-124 Sb-125 I-129 Cs-134 Cs-136 Cs-137 Ba-133 Ba-140 Ce-139 Ce-141 Ce-144 Nd-147 Pm-144 Pm-146 Eu-152 Eu-154 Eu-155 Ir-192 Hg-203 Tl-208 Pb-210 Pb-212 Pb-214 Bi-212 Bi-214 Ra-228 Ac-228 Th-234 U-235 U-238 Np-239 Am-241 04/21/16 04/21/16 04/27/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16 04/21/16

-3.65E+00 8.30E+00

-3.73E-02

-1.30E+01 5.93E+00 1.13E+03

-7.26E+00

-1.12E+01

-8.99E+00

-9.12E+00 3.42E+01

-8.63E+01 1.21E+00 4.46E+00 1.35E+01 1.78E+01 1.43E+01

-2.79E+00 8.62E+00 8.75E+00 9.04E+02

-1.47E+00

-6.77E+00

-6.90E+01

-1.64E+00 4.22E+01 4.22E+01 3.77E+02

-3.80E+01 3.77E+02 7.01E+01

-2.43E+01 1.09E+01 2.74E+01 8.59E-01 1.47E+01 3.45E+01 2.43E+01 1.32E+01 6.57E+01 8.66E+00 1.67E+01 5.98E+01 1.33E+02 1.14E+01 1.29E+01 2.86E+01 2.25E+01 3.04E+01 9.96E+00 1.07E+01 1.20E+01 1.07E+03 1.92E+01 2.15E+01 1.77E+02 2.21E+01 6.30E+01 6.30E+01 3.56E+02 5.95E+01 3.56E+02 7.43E+01 4.16E+01 1.88E+01 4.64E+01 1.51E+00 2.52E+01 5.84E+01 2.06E+01 2.09E+01 1.10E+02 1.42E+01 2.77E+01 9.96E+01 2.22E+02 1.88E+01 2.19E+01 4.91E+01 3.83E+01 5.10E+01 1.71E+01 1.86E+01 1.91E+01 1.84E+03 3.09E+01 3.65E+01 2.89E+02 3.64E+01 1.08E+02 1.08E+02 5.78E+02 9.77E+01 5.78E+02 1.32E+02 7.09E+01 2.00E+00 1.50E+01 1.80E+01 U

U U

U U

3 U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

3,U U

3,U U

U 1

2 pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Units Page 35 of 49

GEL LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com 10 CFR Part 50/61 Isotope Abundance Report GEL Sample ID:

Matrix:

Client:

Collect Date:

Receive Date:

Client Sample ID:

395827001 Water Vermont Yankee, Entergy Nuclear Operations Inc.

April 11, 2016 April 21, 2016 Torus Water #2 Analyte Activity Alpha Spec Gamma Spec Ni-63 Tc-99 H-3 Cs-137 Co-60 Mn-54 Zn-65 7.94E+02 3.89E+03 1.70E+06 1.13E+03 2.07E+04 4.71E+02 1.95E+03 pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Units

% Abundance 000.05 000.22 098.31 000.07 001.20 000.03 000.11 Total Activity:

1.73E+06 Total % Abundance:

100.00 Page 36 of 49

Quality Control Summary Page 37 of 49

QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Alpha Spec 1562629 1562630 Batch Batch Plutonium-238 Plutonium-239/240 Plutonium-242 Plutonium-238 Plutonium-239/240 Plutonium-242 Plutonium-238 Plutonium-239/240 Plutonium-242 Americium-241 Curium-242 Curium-243/244 Americium-241 Curium-242 Curium-243/244 Americium-241 Curium-242 Parmname Mr. Mark Vandale

Contact:

Entergy Nuclear Operations, Inc., VY 530 Governor Hunt Road Vernon, Vermont May 5, 2016 Report Date:

Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MXS2 MXS2 04/30/16 11:03 04/30/16 11:03 04/30/16 11:05 04/30/16 11:05 04/30/16 11:08 04/30/16 11:05 QC 0.132 0.0824 0.0763 0.0475 5.71 0.0545 0.0605

-0.0135 0.0215 0.0765 0.00 0.0252 5.27 0.0144 6.22 0.0246

-0.00542 NOM Sample 0.0196 0.0485 0.191 0.0431 0.00

-0.00511 Range N/A N/A N/A (75%-125%)

N/A N/A N/A (75%-125%)

(75%-125%)

Qual U

U U

U U

U U

U U

U U

U U

QC1203535940 395827001 QC1203535941 QC1203535939 QC1203535947 395827001 QC1203535948 QC1203535946 N/A N/A N/A 16.6 N/A N/A REC%

116 107 94.1 4.94 4.93 6.61 DUP LCS MB DUP LCS MB 395827 Workorder:

PO Box 250 U

U U

U U

U

+/-0.214

+/-0.213

+/-0.299

+/-0.0739

+/-0.0466

+/-0.0441

+/-0.142

+/-0.113

+/-0.113

+/-0.107

+/-0.770

+/-0.108

+/-0.0977

+/-0.0611

+/-0.0828

+/-0.101

+/-0.055

+/-0.0707

+/-0.623

+/-0.0539

+/-0.671

+/-0.0949

+/-0.0468 RPD%

Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 1 of 12 Page 38 of 49

QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Alpha Spec Rad Gamma Spec 1562630 1562631 1562632 1561698 Batch Batch Batch Batch Curium-243/244 Neptunium-237 Neptunium-237 Neptunium-237 Plutonium-241 Plutonium-241 Plutonium-241 Actinium-228 Americium-241 Antimony-124 Antimony-125 Barium-133 Barium-140 Beryllium-7 Bismuth-212 Bismuth-214 Cerium-139 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MXS2 MXS2 MJH1 04/30/16 10:57 04/30/16 10:59 04/30/16 10:57 05/04/16 15:25 05/03/16 14:19 05/04/16 13:54 04/22/16 06:34 QC 0.00629 0.225 91.8 0.0941

-1.65 216

-1.4

-83.9

-30.2 1.84

-5.76

-11.2 55.0 51.4 27.2 1.58 1.86 NOM Sample

-0.166 7.38 42.2

-24.3

-3.65 8.30

-7.26

-11.2 39.2

-69

-1.64

-8.99 Range N/A (75%-125%)

N/A (75%-125%)

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Qual U

U U

U U

U U

U U

U U

U U

U U

QC1203535950 395827001 QC1203535951 QC1203535949 QC1203535953 395827001 QC1203535954 QC1203535952 QC1203533385 395827001 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A REC%

103 111 89.3 194 DUP LCS MB DUP LCS MB DUP 395827 Workorder:

U U

U U

U U

U U

U U

U U

+/-0.314

+/-11.3

+/-63.0

+/-41.6

+/-10.9

+/-27.4

+/-13.2

+/-65.7

+/-94.0

+/-177

+/-22.1

+/-8.66

+/-0.0657

+/-0.654

+/-6.94

+/-0.422

+/-7.13

+/-27.4

+/-7.62

+/-95.8

+/-50.5

+/-15.8

+/-41.9

+/-20.8

+/-103

+/-144

+/-257

+/-34.0

+/-12.7 RPD%

Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 2 of 12 Page 39 of 49

QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698 Batch Cerium-141 Cerium-144 Cesium-134 Cesium-136 Cesium-137 Chromium-51 Cobalt-56 Cobalt-57 Cobalt-58 Cobalt-60 Europium-152 Europium-154 Europium-155 Iridium-192 Iron-59 Lead-210 Lead-212 Lead-214 Manganese-54 Mercury-203 Neodymium-147 Neptunium-239 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 04/22/16 06:34 QC

-12 16.8

-8.32

-39.4 1150 3.78 5.84 6.90 89.1 20400

-7.81 17.7 20.9

-2.06

-55.9

-414 0.365 7.39 481 0.957

-52.1

-65.9 NOM Sample

-9.12 34.2

-13 5.93 1130 30.7 7.28 3.24 90.0 20700 13.5 17.8 14.3

-2.79 28.7 904

-1.47

-6.77 471 8.62

-86.3 70.1 Range N/A N/A N/A N/A (0%-20%)

N/A N/A N/A (0% - 100%)

(0%-20%)

N/A N/A N/A N/A N/A N/A N/A N/A (0%-20%)

N/A N/A N/A Qual U

U U

U U

U U

U U

U U

U U

U U

U U

U N/A N/A N/A N/A 2.28 N/A N/A N/A 0.982 1.55 N/A N/A N/A N/A N/A N/A N/A N/A 1.95 N/A N/A N/A REC%

395827 Workorder:

U U

U U

U U

U U

U U

U U

U U

U U

U U

+/-16.7

+/-59.8

+/-14.7

+/-34.5

+/-24.3

+/-98.2

+/-15.2

+/-7.66

+/-20.6

+/-71.0

+/-28.6

+/-22.5

+/-30.4

+/-9.96

+/-35.5

+/-1070

+/-19.2

+/-21.5

+/-24.3

+/-10.7

+/-133

+/-74.3

+/-24.6

+/-87.5

+/-22.6

+/-53.9

+/-36.7

+/-147

+/-23.3

+/-12.0

+/-28.7

+/-103

+/-42.7

+/-31.6

+/-44.2

+/-15.4

+/-53.1

+/-1020

+/-26.2

+/-32.0

+/-36.4

+/-15.9

+/-208

+/-115 RPD%

Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 3 of 12 Page 40 of 49

QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698 Batch Niobium-94 Niobium-95 Potassium-40 Promethium-144 Promethium-146 Radium-228 Ruthenium-106 Silver-110m Sodium-22 Thallium-208 Thorium-234 Tin-113 Uranium-235 Uranium-238 Yttrium-88 Zinc-65 Zirconium-95 Actinium-228 Americium-241 Antimony-124 Antimony-125 Barium-133 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 04/22/16 06:34 04/22/16 06:39 QC 14.9 22.9 16.1 1.11

-18.9

-83.9 136 40.9 6.22

-15.1 155 0.622 16.4 155

-5.55 1870

-5.38 122 39700 15.9

-157 27.6 NOM Sample

-7.62 6.97 11.4 1.21 4.46 42.2 31.9

-4.46 6.07 8.75 377 9.02

-38 377

-1.32 1950 23.7 Range N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (0%-20%)

N/A (75%-125%)

Qual U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U QC1203533386 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 3.98 N/A REC%

115 34400 LCS 395827 Workorder:

U U

U U

U U

U U

U U

U U

U U

U U

+/-11.3

+/-13.4

+/-51.6

+/-11.4

+/-12.9

+/-63.0

+/-104

+/-21.4

+/-7.93

+/-12.0

+/-356

+/-12.8

+/-59.5

+/-356

+/-5.08

+/-68.5

+/-24.0

+/-16.4

+/-23.5

+/-69.1

+/-16.5

+/-19.7

+/-95.8

+/-159

+/-33.1

+/-11.1

+/-19.0

+/-425

+/-19.4

+/-85.7

+/-425

+/-7.20

+/-96.7

+/-36.8

+/-399

+/-1740

+/-46.1

+/-241 RPD%

Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 4 of 12 Page 41 of 49

QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698 Batch Barium-140 Beryllium-7 Bismuth-212 Bismuth-214 Cerium-139 Cerium-141 Cerium-144 Cesium-134 Cesium-136 Cesium-137 Chromium-51 Cobalt-56 Cobalt-57 Cobalt-58 Cobalt-60 Europium-152 Europium-154 Europium-155 Iridium-192 Iron-59 Lead-210 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 04/22/16 06:39 QC 153

-119 540

-68.5 43.7

-75.7

-268 23.7

-66.4 13700

-199 81.9 267

-46.9 14200

-101 43.3 146 57.9 45.3 4.51E+05 NOM Sample Range (75%-125%)

(75%-125%)

Qual U

U U

U U

U U

U U

U U

U U

U U

U U

REC%

102 103 13500 13800 395827 Workorder:

+/-103

+/-282

+/-768

+/-1080

+/-142

+/-66.4

+/-112

+/-478

+/-94.4

+/-158

+/-354

+/-630

+/-88.7

+/-108

+/-87.5

+/-408

+/-237

+/-136

+/-300

+/-74.3

+/-199

+/-50700 RPD%

Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 5 of 12 Page 42 of 49

QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698 Batch Lead-212 Lead-214 Manganese-54 Mercury-203 Neodymium-147 Neptunium-239 Niobium-94 Niobium-95 Potassium-40 Promethium-144 Promethium-146 Radium-228 Ruthenium-106 Silver-110m Sodium-22 Thallium-208 Thorium-234 Tin-113 Uranium-235 Uranium-238 Yttrium-88 Zinc-65 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 04/22/16 06:39 QC

-41.7

-66.5 22.0

-25.5

-259 356 9.74 28.1

-26.7 6.91

-31.7 122 166 78.2 14.5

-13.8

-1950

-66.5 147

-1950

-3.09 1030 NOM Sample Range Qual U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

REC%

395827 Workorder:

+/-143

+/-183

+/-87.1

+/-77.1

+/-538

+/-781

+/-68.8

+/-77.3

+/-253

+/-68.5

+/-124

+/-399

+/-727

+/-140

+/-47.5

+/-73.8

+/-5510

+/-108

+/-479

+/-5510

+/-28.7

+/-363 RPD%

Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 6 of 12 Page 43 of 49

QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698 Batch Zirconium-95 Actinium-228 Americium-241 Antimony-124 Antimony-125 Barium-133 Barium-140 Beryllium-7 Bismuth-212 Bismuth-214 Cerium-139 Cerium-141 Cerium-144 Cesium-134 Cesium-136 Cesium-137 Chromium-51 Cobalt-56 Cobalt-57 Cobalt-58 Cobalt-60 Europium-152 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 04/22/16 06:34 QC 31.9

-7.16

-1.73

-0.0387 0.960 0.347

-0.895

-8.86 14.2 1.92

-0.533 2.38 5.24 0.137

-1.24 0.134 1.84 0.706

-0.172 0.680 1.03 1.98 NOM Sample Range Qual U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U QC1203533384 REC%

MB 395827 Workorder:

+/-141

+/-8.38

+/-9.55

+/-2.87

+/-4.35

+/-2.37

+/-6.51

+/-12.3

+/-25.1

+/-4.84

+/-1.59

+/-2.53

+/-10.6

+/-1.84

+/-2.06

+/-1.80

+/-13.4

+/-1.49

+/-1.53

+/-1.64

+/-1.93 RPD%

Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 7 of 12 Page 44 of 49

QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec 1561698 Batch Europium-154 Europium-155 Iridium-192 Iron-59 Lead-210 Lead-212 Lead-214 Manganese-54 Mercury-203 Neodymium-147 Neptunium-239 Niobium-94 Niobium-95 Potassium-40 Promethium-144 Promethium-146 Radium-228 Ruthenium-106 Silver-110m Sodium-22 Thallium-208 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 04/22/16 06:34 QC

-0.771

-2.76

-0.317 2.12

-132 1.26 1.93

-0.12 1.53

-3.95

-0.573

-0.765

-0.0743 14.3 0.643 0.158

-7.16

-15.7

-0.238

-0.342

-2.26 NOM Sample Range Qual U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

REC%

395827 Workorder:

+/-4.87

+/-4.66

+/-6.43

+/-1.62

+/-2.97

+/-275

+/-4.97

+/-5.83

+/-1.62

+/-1.59

+/-11.0

+/-14.9

+/-1.67

+/-1.40

+/-24.8

+/-1.79

+/-2.18

+/-8.38

+/-18.9

+/-1.98

+/-1.62

+/-2.16 RPD%

Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 8 of 12 Page 45 of 49

QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gamma Spec Rad Gas Flow 1561698 1562602 1562693 1562716 Batch Batch Batch Batch Thorium-234 Tin-113 Uranium-235 Uranium-238 Yttrium-88 Zinc-65 Zirconium-95 Iodine-129 Iodine-129 Iodine-129 Iodine-129 Nickel-59 Nickel-59 Nickel-59 Strontium-89 Strontium-90 Strontium-89 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time MJH1 MJH1 CXS7 KSD1 04/22/16 06:34 04/27/16 09:20 04/27/16 11:04 04/27/16 09:19 04/27/16 09:20 04/28/16 15:36 04/29/16 06:45 04/28/16 15:36 05/02/16 16:24 05/02/16 16:24 QC 60.3 0.153

-0.388 60.3

-0.798 0.806

-1.7 0.388 50.2

-0.17 57.5 3.14 372 2.87

-1.39

-0.222 550 NOM Sample

-0.0373

-0.0373 5.85 1.08 0.331 Range N/A (75%-125%)

(75%-125%)

N/A (75%-125%)

N/A N/A (75%-125%)

Qual U

U U

U U

U U

U U

U U

U U

QC1203535844 395827001 QC1203535846 QC1203535843 QC1203535845 395827001 QC1203536150 395827001 QC1203536151 QC1203536149 QC1203536198 395827001 QC1203536199 N/A N/A N/A N/A REC%

96.4 111 88.8 105 52.0 52.0 419 522 DUP LCS MB MS DUP LCS MB DUP LCS 395827 Workorder:

U U

U U

U

+/-0.859

+/-0.859

+/-6.40

+/-1.29

+/-0.980

+/-140

+/-2.10

+/-13.5

+/-140

+/-1.85

+/-3.61

+/-2.56

+/-1.13

+/-6.44

+/-0.835

+/-6.83

+/-2.49

+/-26.7

+/-5.02

+/-1.93

+/-1.22 RPD%

Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 9 of 12 Page 46 of 49

QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Gas Flow Rad Liquid Scintillation 1562716 1562672 1562678 1562683 1562687 Batch Batch Batch Batch Batch Strontium-90 Strontium-89 Strontium-90 Iron-55 Iron-55 Iron-55 Nickel-63 Nickel-63 Nickel-63 Technetium-99 Technetium-99 Technetium-99 Tritium Tritium Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time KSD1 CXS7 CXS7 MYM1 GXR1 05/02/16 16:24 05/02/16 16:27 04/28/16 23:26 04/29/16 00:13 04/28/16 22:39 04/29/16 14:53 04/29/16 15:09 04/29/16 14:37 05/03/16 15:12 05/03/16 15:28 05/03/16 14:55 04/29/16 23:11 04/30/16 11:54 QC 445

-1.5 0.116 91.2 1440

-42.5 840 2090

-6.46 254 841

-11.4 1.72E+06 2410 NOM Sample 95.3 794 3890 1.70E+06 Range (75%-125%)

(0% - 100%)

(75%-125%)

(0%-20%)

(75%-125%)

(0%-20%)

(75%-125%)

(0%-20%)

(75%-125%)

Qual U

U U

U U

QC1203536197 QC1203536077 395827001 QC1203536078 QC1203536076 QC1203536093 395827001 QC1203536094 QC1203536092 QC1203536112 395827001 QC1203536113 QC1203536111 QC1203536127 395827001 QC1203536129 4.42 5.65 175 1.36 REC%

83 86.8 124 97.7 102 536 1660 1690 861 2350 MB DUP LCS MB DUP LCS MB DUP LCS MB DUP LCS 395827 Workorder:

+/-60.5

+/-71.2

+/-93.7

+/-33300

+/-13.0

+/-10.4

+/-1.18

+/-1.00

+/-58.8

+/-86.2

+/-58.1

+/-71.1

+/-101

+/-37.6

+/-33.3

+/-48.9

+/-24.1

+/-33700

+/-461 RPD%

Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Page 10 of 12 Page 47 of 49

QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Rad Liquid Scintillation 1562687 1562691 Batch Batch Tritium Tritium Carbon-14 Carbon-14 Carbon-14 Carbon-14 Parmname Units pCi/L pCi/L pCi/L pCi/L pCi/L pCi/L Anlst Date Time GXR1 TXJ1 04/29/16 22:55 04/29/16 23:13 05/03/16 17:23 05/03/16 18:26 05/03/16 16:51 05/03/16 17:54 QC 136 1.62E+06 28.0 1310

-4.59 1400 NOM Sample 1.70E+06 14.9 14.9 Range (75%-125%)

N/A (75%-125%)

(75%-125%)

Qual U

U U

QC1203536126 QC1203536128 395827001 QC1203536142 395827001 QC1203536144 QC1203536141 QC1203536143 395827001 The Qualifiers in this report are defined as follows:

N/A REC%

N/A 103 111 4710 1260 1260 MB MS DUP LCS MB MS 395827 Workorder:

BD FA H

J K

L M

M N/A N1 ND NJ Q

R U

Analyte is a Tracer compound Result is less than value reported Result is greater than value reported Results are either below the MDC or tracer recovery is low Failed analysis.

Analytical holding time was exceeded Value is estimated Analyte present. Reported value may be biased high. Actual value is expected to be lower.

Analyte present. Reported value may be biased low. Actual value is expected to be higher.

M if above MDC and less than LLD REMP Result > MDC/CL and < RDL RPD or %Recovery limits do not apply.

See case narrative Analyte concentration is not detected above the detection limit Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier One or more quality control criteria have not been met. Refer to the applicable narrative or DER.

Sample results are rejected Analyte was analyzed for, but not detected above the MDL, MDA, MDC or LOD.

U U

+/-33300

+/-24.1

+/-24.1

+/-301

+/-31600

+/-24.9

+/-47.0

+/-23.6

+/-49.8 RPD%

Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Uncertainty Notes:

Counting Uncertainty is calculated at the 95% confidence level (1.96-sigma).

Page 11 of 12 Page 48 of 49

QC Summary GEL LABORATORIES LLC 2040 Savage Road Charleston, SC 29407 - (843) 556-8171 - www.gel.com Parmname Page 12 of 12 Units Anlst Date Time QC NOM Sample Range Qual REC%

395827 Workorder:

UI UJ UL X

Y

^

h Gamma Spectroscopy--Uncertain identification Gamma Spectroscopy--Uncertain identification Not considered detected. The associated number is the reported concentration, which may be inaccurate due to a low bias.

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Other specific qualifiers were required to properly define the results. Consult case narrative.

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL. Qualifier Not Applicable for Radiochemistry.

Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more or %RPD not applicable.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptance criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

  • Indicates that a Quality Control parameter was not within specifications.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

RPD%

Page 49 of 49