{{#Wiki_filter:,Gray, Harold From: John White Sent: Friday, May 15, 2009 8:13 AM , -To: Neil Sheehan Cc: Ronald Nimitz; Harold Gray; John Richmond  
{{#Wiki_filter:,Gray, Harold From:                     John White Sent:                     Friday, May 15, 2009 8:13 AM                     ,           -
To:                       Neil Sheehan Cc:                       Ronald Nimitz; Harold Gray; John Richmond


==Subject:==
==Subject:==
RE: Question re: Oyster Creek inspections A 6" aluminum pipe (A-4, condensate pumps to turbine building) in the same area was inspected previously.
RE: Question re: Oyster Creek inspections A 6" aluminum pipe (A-4, condensate pumps to turbine building) in the same area was inspected previously.
The leaking pipes were CS-24 (10" carbon steel associated with hotwell level control) and CS-25 (8" carbon steel associated with hotwell level control. They were not selected for prior inspection.
The leaking pipes were CS-24 (10" carbon steel associated with hotwell level control) and CS-25 (8" carbon steel associated with hotwell level control. They were not selected for prior inspection.
From: Neil Sheehan Sent: Thursday, May 14, 2009 4:06 PM'To: John White  
From: Neil Sheehan Sent: Thursday, May 14, 2009 4:06 PM
'To: John White


==Subject:==
==Subject:==
Question re: Oyster Creek inspections Can you refresh my memory on this?Neil: RE: Al. At least one of them was inspected by Exelon but it looks like in a different spot.'Were one or both pipes with leaks inspected before the plant's license was renewed and, if so, where and when and what were the results?Thanks.Todd}}
Question re: Oyster Creek inspections Can you refresh my memory on this?
Neil:
RE: Al. At least one of them was inspected by Exelon but it looks like in a different spot.'
Were one or both pipes with leaks inspected before the plant's license was renewed and, if so, where and when and what were the results?
Thanks.
Todd}}

Revision as of 00:49, 14 November 2019

E-mail from J. White to N. Sheehan, Question Related to Oyster Creek Inspections
ML093080803
Person / Time
Site: Oyster Creek
Issue date: 05/15/2009
From: Jason White
NRC/RGN-I/DRS/PSB2
To: Neil Sheehan
NRC Region 1
References
FOIA/PA-2009-0214
Download: ML093080803 (1)


Text

,Gray, Harold From: John White Sent: Friday, May 15, 2009 8:13 AM , -

To: Neil Sheehan Cc: Ronald Nimitz; Harold Gray; John Richmond

Subject:

RE: Question re: Oyster Creek inspections A 6" aluminum pipe (A-4, condensate pumps to turbine building) in the same area was inspected previously.

The leaking pipes were CS-24 (10" carbon steel associated with hotwell level control) and CS-25 (8" carbon steel associated with hotwell level control. They were not selected for prior inspection.

From: Neil Sheehan Sent: Thursday, May 14, 2009 4:06 PM

'To: John White

Subject:

Question re: Oyster Creek inspections Can you refresh my memory on this?

Neil:

RE: Al. At least one of them was inspected by Exelon but it looks like in a different spot.'

Were one or both pipes with leaks inspected before the plant's license was renewed and, if so, where and when and what were the results?

Thanks.

Todd