,Gray, Harold From:
John White Sent:
Friday, May 15, 2009 8:13 AM To:
Neil Sheehan Cc:
Ronald Nimitz; Harold Gray; John Richmond
Subject:
RE: Question re: Oyster Creek inspections A 6" aluminum pipe (A-4, condensate pumps to turbine building) in the same area was inspected previously.
The leaking pipes were CS-24 (10" carbon steel associated with hotwell level control) and CS-25 (8" carbon steel associated with hotwell level control. They were not selected for prior inspection.
From: Neil Sheehan Sent: Thursday, May 14, 2009 4:06 PM
'To: John White
Subject:
Question re: Oyster Creek inspections Can you refresh my memory on this?
Neil:
RE: Al. At least one of them was inspected by Exelon but it looks like in a different spot.'
Were one or both pipes with leaks inspected before the plant's license was renewed and, if so, where and when and what were the results?