- 05000339/LER-1982-050, Forwards LER 82-050/03L-0 + (ML20063N521)
- 05000339/LER-1982-050-03, /03L-0:on 820816,RHR Pump 1A Removed from Svc Leaving One Loop for Decay Heat Removal Operable.Caused by Need to Replace Mechanical Seal Due to Primary O Ring Overheating + (ML20063N524)
- PLA-1238, Responds to NRC Re Violations Noted in IE Emergency Preparedness Appraisal Rept 50-387/82-12. Corrective Actions:Procedure Will Be Revised to Reflect Lead Shift Technical Advisor Responsibilities + (ML20063N525)
- 05000311/LER-1982-091, Forwards LER 82-091/01T-0.Detailed Event Analysis Encl + (ML20063N536)
- 05000311/LER-1982-091-01, /01T-0:on 820906,containment Fan Coil Unit 23 Found Leaking Svc Water.Caused by Erosion of Copper Nickel Cooling Coils by Silt Laden Svc Water.Leaking Coil Blanked Off.Coils Will Be Replaced W/Erosion Resistant Matl + (ML20063N545)
- 05000321/LER-1982-079, Forwards LER 82-079/03L-0 + (ML20063N560)
- 05000346/LER-1982-037, Forwards LER 82-037/03L-0 + (ML20063N562)
- ML20063N564 + (ML20063N564)
- 05000321/LER-1982-079-03, /03L-0:on 820819,reactor Water Cleanup Sys Differential Flow Instrument F.T. & C. Test Not Completed as Required by Tech Specs.Caused by Personnel Error.Person Responsible Reprimanded & Counseled + (ML20063N566)
- 05000346/LER-1982-037-03, /03L-0:on 820816,door 306 Failed to Close Properly,Due to Bent Bottom Seal Plate.Cause Unknown.Seal Plate Replaced to Allow Proper Door Operation + (ML20063N567)
- ML20063N568 + (ML20063N568)
- 05000311/LER-1982-072-03, /03L-0:on 820820,reactor Trip Breaker B Would Not Trip as Required During Surveillance Testing.Caused by Failure of Undervoltage Coil.Reactor Trip Breaker Replaced W/Train Bypass Breaker a + (ML20063N571)
- ML20063N573 + (ML20063N573)
- ML20063N576 + (ML20063N576)
- AECM-82-389, Discusses Independent Design Review Per License Condition 2.C(43).Design Verification Program to Provide Addl Assurance That Design & Const Activities Meet 10CFR50,App B Requirements Will Be Performed by Cygna Energy Svcs + (ML20063N581)
- ML20063N584 + (ML20063N584)
- ML20063N585 + (ML20063N585)
- ML20063N590 + (ML20063N590)
- ML20063N592 + (ML20063N592)
- ML20063N593 + (ML20063N593)
- ML20063N594 + (ML20063N594)
- ML20063N595 + (ML20063N595)
- ML20063N603 + (ML20063N603)
- ML20063N619 + (ML20063N619)
- ML20063N620 + (ML20063N620)
- ML20063N624 + (ML20063N624)
- ML20063N626 + (ML20063N626)
- ML20063N628 + (ML20063N628)
- ML20063N629 + (ML20063N629)
- ML20063N632 + (ML20063N632)
- IR 05000261/2019006 + (ML20063N636)
- 05000280/LER-1982-083, Forwards LER 82-083/03L-0 & Updated LER 82-084/01X-1 + (ML20063N639)
- ML20063N641 + (ML20063N641)
- 05000280/LER-1982-083-03, /03L-0:on 820831,performance of PT-27E Revealed That Amp Reading for Heat Tracing Panel 9,circuit 2B,was Below Acceptance Criteria.Caused by Excessive Heat.Heat Tracing Replaced & Tested + (ML20063N643)
- ML20063N644 + (ML20063N644)
- 05000280/LER-1982-084-01, Venting of a Charging Pump Resulted in Max Instantaneous Release Rate Being Exceeded.Caused by Failure to Change Radiation Monitor Setpoint Alarms to Reflect New Vent Sys Flow Rates + (ML20063N645)
- 05000280/LER-1982-086, Forwards LER 82-086/03L-0 + (ML20063N649)
- 05000280/LER-1982-086-03, /03L-0:on 820827,radiation Monitor RM-LW-10F Indicated 9.0E4 CPM W/O Annunciation of Alarm.Caused by Defective Push Button & Setpoint Drift.Push Button Replaced & Monitor Recalibr + (ML20063N651)
- ML20063N653 + (ML20063N653)
- ML20063N654 + (ML20063N654)
- ML20063N655 + (ML20063N655)
- ML20063N658 + (ML20063N658)
- ML20063N660 + (ML20063N660)
- ML20063N662 + (ML20063N662)
- ML20063N665 + (ML20063N665)
- ML20063N666 + (ML20063N666)
- ML20063N667 + (ML20063N667)
- ML20063N669 + (ML20063N669)
- ML20063N671 + (ML20063N671)
- ML20063N673 + (ML20063N673)
- RBG-13-442, Interim Deficiency Rept Re Improper Installation (Torquing) & Insp of drilled-in expansion-type Anchors.Initially Reported on 820830.Investigation Continuing.Final Status Rept Will Be Provided by 821115 + (ML20063N675)