Browse wiki

Jump to navigation Jump to search
The inspectors identified a finding of verThe inspectors identified a finding of very low safety significance and associated non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensees failure to have adequate procedures in place to ensure that heavy loads were operated safely within the primary auxiliary building (PAB). Specifically, the inspectors determined that the licensee failed to incorporate minimum crane operating temperature limits into procedures to avoid brittle fracture of structural components below the nil-ductility transition temperature. The issue was entered into the licensees corrective action program for resolution as action request AR01783306 for evaluation and development of corrective actions which included revising procedures to identify the minimum operating temperature of the PAB crane. The finding was determined to be more than minor in accordance with IMC 0612, Power Reactor Inspection Reports, Appendix B, Issue Screening, dated September 7, 2012, because it was associated with the Barrier Integrity Cornerstone attribute of procedure quality and adversely affected the cornerstone objective to provide reasonable assurance that physical design barriers protect the public from radionuclide releases caused by accidents or events because a PAB crane heavy load drop could cause damage to spent fuel. The inspectors evaluated the finding using IMC 0609, Significance Determination Process, Attachment 0609.04, Initial Characterization of Findings, Tables 2 and 3, dated June 19, 2012, and Appendix A, The Significance Determination Process (SDP) for Findings At-Power, Exhibit 3 for the Barrier Integrity Cornerstone, dated June 19, 2012. The inspectors answered No to Exhibit 3 questions in Appendix A for the spent fuel pool. Therefore, the inspectors determined the finding to be of very low safety significance. In accordance with IMC 0612, Section 06.03.c, a cross-cutting aspect will not be assigned to this finding as it has occurred outside of the nominal three-year period and is not representative of present performance.not representative of present performance.  
23:59:59, 30 September 2012  +
05000266  +  and 05000301  +
23:59:59, 30 September 2012  +
Has query"Has query" is a predefined property that represents meta information (in form of a <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Subobject">subobject</a>) about individual queries and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
Modification date"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by <a rel="nofollow" class="external text" href="https://www.semantic-mediawiki.org/wiki/Help:Special_properties">Semantic MediaWiki</a>.
00:46:23, 21 February 2018  +
23:59:59, 30 September 2012  +
Inadequate Procedural Guidance for Heavy Loads Operations  +